| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Model self contained, powered signal conditioner bridge type instrumen
Top Searches for this datasheetModel Bridgesensor Model self contained, powered signal conditioner bridge type instrumentation. contains precision instrumentation amplifier with isolated, filtered output highly regulated, noise, adjustable output bridge excitation source. unit completely encapsulated rugged environments. Complete Strain Gage Bridge Signal Conditioner Isolated 4-20 0-20 Output Output Capable Driving 1000 Loop Bridge Balance with Tare Offset Capability High Gain Amplifier; Accept Full Scale Live Load Signals Provide Output Span Excitation Supply Capable Driving Four Load Cells Powered Rugged Epoxy Encapsulated Design Applications Weighing with Load Cells Process Control Add-on Loops Used With Types Output Sensors Block Diagram 2401 Stanwell Drive Concord, 94520-4841 (510) 687-4411 (510) 687-3333 http://www.calex.com CALEX FaxFACTS: 1997 Model Bridgesensor Specifications NOTE: Unless otherwise noted, specifications apply after hour warm 25°C ambient. Temperature coefficients apply between 55°C ambient. Isolation Input Output Amplifier Gain Adjustment Range Input Output Linearity Temperature Stability Input Noise Tare Adjustment Range Bridge Offset Input Resistance Differential Common Mode 1000 megohm Common Mode Rejection, minimum Common Mode Input Volts Output Zero Adjust Temperature Coefficient Current Output Span Compliance Voltage Current Loop Resistance Frequency Response, -3dB Response Time Rise Time 0.1% Final Value Bridge Supply Voltage Adjustment Range Temperature Coefficient Fixed Temperature Coefficient Load Current Regulation Load Line Output Noise Bandwidth Input Optional Line Isolation Capacitance Dielectric Withstand Environment Ambient Operating Storage Weight 1mA/ Volts 1000 ohms Hertz, Pole Roll Volts Typical 10.2V ±2.5% Typical 0.02% maximum RMS, maximum VAC, ±10V 50/60 100, VAC, -10% 1100 Volts -25°C +55°C -25°C +85°C (510 grams) 3.75" 2.0" 2.87" (9.53 7.62 60pF Getting Started with Model Excitation Supply. remote sensing used, connect +Sense +Excitation, terminal connect -Sense -Excitation, terminal Apply power Model adjust Excitation supply. Turn SWB-1 "ON" fixed Volts. This will supply 10.2 ±2.5% provide best temperature stability. voltages between Volts, place SWB-1 "OFF" position Excitation Supply with potentiometer SWB-2 either position. Turn power Model connect load cell Model Excitation terminals Amplifier Inputs. Turn power 433. Turn SWA-3 "ON". output ZERO current with Select expected full scale signal range according table with SWA-4 SWA-5. output from load cell known, both SW-4 SW-5 "ON" 40-50mV range. SWA-2 "OFF" SWA-2 "ON" output ZERO. Adjust potentiometer desired ZERO current. Turn SWA-3 "OFF". Expect output current change. ±0.01% Full Scale (0.005%/°C) (Equals F.S. mV/V cell) Apply load dead weight load cell. Adjust TARE potentiometers same ZERO current Step SWA-1 "OFF" provides bridge output balance -3mV +15mV, "ON" between +15mV +25mV. Apply full scale load adjust SPAN (GAIN) potentiometer desired full scale output current. Range switches SWA-4 SWA-5 required. Remove full scale load check ZERO output current. Adjust FINE TARE potentiometer required. Recheck full scale Step End. Note: amplifier used without using Excitation Supply, external power supply side must connected -EXCITATION terminal Model 433, inputs must tied terminal -EXCITATION. This provides return path finite amplifier input current. Amplifier amplifier true differential input, drift Instrumentation Amplifier with less than 100pA input current. common mode range Volts with respect EXCITATION supply terminal minimum 100dB rejection common mode voltage. input amplifier excitation 2401 Stanwell Drive Concord, 94520-4841 (510) 687-4411 (510) 687-3333 http://www.calex.com CALEX FaxFACTS: 1997 Model Bridgesensor supply isolated from line current output. isolated output current source compliance Volts allow Model operate with zero 1000 Ohms loop resistance. Control Switch Tare Weight Compensation Model different zero controls. called OUTPUT zero with SWA2. other zero control called TARE. SWA-1 allows selection TARE ranges, -3mV 15mV +15mV +25mV. Potentiometers available COARSE FINE TARE adjustments. SWA-1 SWA-2 SWA-4 SWA-5 Tare Range -3mV Zero Current Span Range Connecting Sensor amplifier finite input current which must have return path amplifier power supplies. This path automatically provided when Model Bridge Excitation Supply used excite sensor. external supply used, side external supply must connected Model common, Terminal sure that common mode voltage limits observed. This would generally limit external power supply Volts assuming that half voltage would common mode, case when exciting full bridge. When full scale output sensor measured millivolts, millivolts, care must exercised wiring systems. millivolts full scale, each microvolt (10-6 volts) contributes 0.01% full scale output. Wire connections generate microvolts potential contact potentials. These will also thermoelectric potentials thus vary with temperature differences. wires used connecting Model should same material. intervening connections made such terminal block, terminal block connecting points should have good thermal contact they will always same temperature thus cancel each other. Mechanical Specifications Transducer Excitation bridge excitation supply voltage SWB-1 potentiometer SWB-1 fixed Volts. This will provide best temperature stability. supply adjusted between Volts setting SWB-1 adjusting potentiometer supply will deliver 120mA current voltage setting power four sensors. Excitation Voltage Terminal Strip Assignments Screw Terminal Function Screw Terminal Function SWB-1 Excitation Voltage Fixed Volts Adjustable 2401 Stanwell Drive Concord, 94520-4841 (510) 687-4411 (510) 687-3333 http://www.calex.com CALEX FaxFACTS: -SENSE -EXCITATION +SENSE +EXCITATION +SIGNAL -SIGNAL OUTPUT RETURN 1997 Other recent searchesTS68302 - TS68302 TS68302 Datasheet TA1042A - TA1042A TA1042A Datasheet PA2010 - PA2010 PA2010 Datasheet SMPA2010 - SMPA2010 SMPA2010 Datasheet MMBV432LT1 - MMBV432LT1 MMBV432LT1 Datasheet MCP73837 - MCP73837 MCP73837 Datasheet MCP73838 - MCP73838 MCP73838 Datasheet FC128 - FC128 FC128 Datasheet CXD2457R - CXD2457R CXD2457R Datasheet ICX204AK - ICX204AK ICX204AK Datasheet
Privacy Policy | Disclaimer |