| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
H8/3217 Series QFP-64A User System Interface Cable (HS3217ECH61H) E600
Top Searches for this datasheetH8/3217 Series QFP-64A User System Interface Cable (HS3217ECH61H) E6000 Emulator User's Manual HS3217ECH61HE(B) IMPORTANT INFORMATION READ FIRST READ this user's manual before using this user system interface cable. KEEP user's manual handy future reference. attempt user system interface cable until fully understand mechanism. User System Interface Cable: Throughout this document, term "user system interface cable" shall defined following product produced only Hitachi, Ltd. excluding subsidiary products. User system interface cable (HS3217ECN61H) user system host computer included this definition. Purpose User System Interface Cable: This user system interface cable connecting emulator station user system. This user system interface cable must only used above purpose. Improvement Policy: Hitachi, Ltd. (including subsidiaries, hereafter collectively referred Hitachi) pursues policy continuing improvement design, performance, functions, safety user system interface cable. Hitachi reserves right change, wholly partially, specifications, design, user's manual, other documentation time without notice. Target User User System Interface Cable: This user system interface cable should only used those have carefully read thoroughly understood information restrictions contained user's manual. attempt user system interface cable until fully understand mechanism. highly recommended that first-time users instructed users that well versed operation user system interface cable. LIMITED WARRANTY Hitachi warrants user system interface cables manufactured accordance with published specifications free from defects material and/or workmanship. Hitachi will repair replace user system interface cables determined defective material and/or workmanship. User system interface cables wearing parts which Hitachi will repair replace damaged and/or worn through use. foregoing shall constitute sole remedy breach Hitachi's warranty. This warranty extends only you, original Purchaser. transferable anyone subsequently purchases user system interface cable from you. Hitachi liable claim made third party made third party. DISCLAIMER HITACHI MAKES WARRANTIES, EITHER EXPRESS IMPLIED, ORAL WRITTEN, EXCEPT PROVIDED HEREIN, INCLUDING WITHOUT LIMITATION THEREOF, WARRANTIES MARKETABILITY, MERCHANTABILITY, FITNESS PARTICULAR PURPOSE USE, AGAINST INFRINGEMENT PATENT. EVENT SHALL HITACHI LIABLE DIRECT, INCIDENTAL CONSEQUENTIAL DAMAGES NATURE, LOSSES EXPENSES RESULTING FROM DEFECTIVE USER SYSTEM INTERFACE CABLE, USER SYSTEM INTERFACE CABLE, DOCUMENTATION, EVEN ADVISED POSSIBILITY SUCH DAMAGES. EXCEPT EXPRESSLY STATED OTHERWISE THIS WARRANTY, THIS USER SYSTEM INTERFACE CABLE SOLD MUST ASSUME RISK RESULTS OBTAINED FROM USER SYSTEM INTERFACE CABLE. State Law: Some states allow exclusion limitation implied warranties liability incidental consequential damages, above limitation exclusion apply you. This warranty gives specific legal rights, have other rights which vary from state state. Warranty Void Following Cases: Hitachi shall have liability legal responsibility problems caused misuse, abuse, misapplication, neglect, improper handling, installation, repair modifications user system interface cable without Hitachi's prior written consent problems caused user system. Rights Reserved: This user's manual user system interface cable copyrighted rights reserved Hitachi. part this user's manual, part, reproduced duplicated form, hard-copy machine-readable form, means available without Hitachi's prior written consent. Other Important Things Keep Mind: Circuitry other examples described herein meant merely indicate characteristics performance Hitachi's semiconductor products. Hitachi assumes responsibility intellectual property claims other problems that result from applications based examples described herein. license granted implication otherwise under patents other rights third party Hitachi. Figures: Some figures this user's manual show items different from your actual system. Limited Anticipation Danger: Hitachi cannot anticipate every possible circumstance that might involve potential hazard. warnings this user's manual user system interface cable therefore inclusive. Therefore, must user system interface cable safely your risk. SAFETY PAGE READ FIRST READ this user's manual before using this user system interface cable. KEEP user's manual handy future reference. attempt user system interface cable until fully understand mechanism. DEFINITION SIGNAL WORDS This safety alert symbol. used alert potential personal injury hazards. Obey safety messages that follow this symbol avoid possible injury death. DANGER DANGER indicates imminently hazardous situation which, avoided, will result death serious injury. WARNING indicates potentially hazardous situation which, avoided, could result death serious injury. CAUTION indicates potentially hazardous situation which, avoided, result minor moderate injury. CAUTION used without safety alert symbol indicates potentially hazardous situation which, avoided, result property damage. WARNING CAUTION CAUTION NOTE emphasizes essential information. WARNING Observe precautions listed below. Failure will result FIRE HAZARD will damage user system emulator product will result PERSONAL INJURY. USER PROGRAM will LOST. repair remodel emulator product yourself electric shock prevention quality assurance. Always switch E6000 emulator user system before connecting disconnecting CABLES PARTS. Always before connecting CABLES, make sure that both sides correctly aligned. Cautions Hitachi neither warrants grants licenses rights Hitachi's third party's patent, copyright, trademark, other intellectual property rights information contained this document. Hitachi bears responsibility problems that arise with third party's rights, including intellectual property rights, connection with information contained this document. Products product specifications subject change without notice. Confirm that have received latest product standards specifications before final design, purchase use. Hitachi makes every attempt ensure that products high quality reliability. However, contact Hitachi's sales office before using product application that demands especially high quality reliability where failure malfunction directly threaten human life cause risk bodily injury, such aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment medical equipment life support. Design your application that product used within ranges guaranteed Hitachi particularly maximum rating, operating supply voltage range, heat radiation characteristics, installation conditions other characteristics. Hitachi bears responsibility failure damage when used beyond guaranteed ranges. Even within guaranteed ranges, consider normally foreseeable failure rates failure modes semiconductor devices employ systemic measures such fail-safes, that equipment incorporating Hitachi product does cause bodily injury, fire other consequential damage operation Hitachi product. This product designed radiation resistant. permitted reproduce duplicate, form, whole part this document without written approval from Hitachi. Contact Hitachi's sales office questions regarding this document Hitachi semiconductor products. Preface Thank purchasing E6000 emulator Hitachi's original microprocessor H8/300 series. HS3217ECH61H user system interface cable that connects H8/300 series E6000 emulator (HS3008EPI60H; hereinafter referred emulator) socket QFP-64A package (package code: FP-64A) H8/3217 series user system. Contents Section Configuration Section Connection Procedures Connecting User System Interface Cable Emulator Station Connecting User System Interface Cable User System 2.2.1 Installing Socket 2.2.2 Soldering Socket.6 2.2.3 Inserting Cable Head 2.2.4 Fastening Cable Head.7 2.2.5 Fastening Cable Body.9 Recommended Dimensions User System Mount Dimensions User System Interface Cable Head.11 Resulting Dimensions after Connecting User System Interface Cable Section Installing User System Section Verifying Operation Section Notice.16 Section Configuration CAUTION IC149-064-008-B5 socket (manufactured YAMAICHI ELECTRONICS Co., Ltd.) FP-64A package socket user system. Figure shows configuration HS3217ECH61H user system interface cable FP-64A package. Screws (M2.0 flat washers Screws (M2.0 flat washers (For fastening cable head) Socket cover Cable head socket User system Figure HS3217ECH61H User System Interface Cable Table lists HS3217ECH61H components. Please make sure have these components when unpacking. Table HS3217ECH61H Components Quantity FP-64A package installing FP-64A-packaged fastening cable head (with four flat washers) installing FP-64A-packaged (with four flat washers) User's manual HS3217ECH61H (this manual) Remarks Includes flat cable Component Cable body Cable head socket Socket cover Screws (M2.0 Screws (M2.0 Documentation Section Connection Procedures Connecting User System Interface Cable Emulator Station WARNING Observe precautions listed below. Failure will result FIRE HAZARD will damage user system emulator product will result PERSONAL INJURY. USER PROGRAM will LOST. Always switch user system emulator product before USER SYSTEM INTERFACE CABLE connected removed from part. Before connecting, make sure that both sides correctly aligned. user system interface cable dedicated emulator must used. connect cable body emulator station, follow instructions below. Make sure user system emulator station turned off. After making sure direction cable body connector correct, firmly insert cable body connector into emulator station socket (figure Figure Connecting User System Interface Cable Emulator Station Connecting User System Interface Cable User System WARNING Always switch user system emulator product before USER SYSTEM INTERFACE CABLE connected removed from part. Before connecting, make sure that both sides correctly aligned. Failure will result FIRE HAZARD will damage user system emulator product will result PERSONAL INJURY. USER PROGRAM will LOST. connect cable head user system, follow instructions below. 2.2.1 Installing Socket After checking location socket, apply epoxy resin adhesive bottom socket FP-64A package, fasten user system before soldering. 2.2.2 Soldering Socket After fastening, solder socket FP-64A package user system. sure completely solder leads that solder slops gently over leads forms solder fillets. (Use slightly more solder than MCU.) 2.2.3 Inserting Cable Head CAUTION Check location before inserting. Align socket FP-64A package user system with user system interface cable head, insert user system interface cable head into socket user system, shown figure 2.2.4 Fastening Cable Head CAUTION Phillips-type screwdriver whose head matches screw head. tightening torque must 0.0784 less. applied torque cannot accurately measured, stop tightening when force required turn screw becomes significantly greater than that needed when first tightening. screw tightened much, screw head break socket contact error caused crack socket solder. emulator does operate correctly, cracks might have occurred solder. Check conduction with tester re-solder socket necessary. Fasten user system interface cable head socket FP-64A package user system with four screws (M2.0 provided. Each screw should tightened little time, alternating between screws opposing corners. Take special care, such manually securing socket soldered area, prevent soldered socket from being damaged overtightening screws twisting components. Screws (M2.0 flat washers Cable head socket (IC149-064-008-B5 manufactured YAMAICHI ELECTRONICS Co., Ltd.) User system Figure Connecting User System Interface Cable User System 2.2.5 Fastening Cable Body Connect cable body cable head. Cable body Removing Push unfastening Unfastening Cable head User system Figure Fastening Cable Body Recommended Dimensions User System Mount Figure shows recommended dimensions mount (footprint) user system with socket FP-64A package (IC149-064-008-B5: manufactured YAMAICHI ELECTRONICS Co., Ltd.). Note that dimensions figure somewhat different from those actual chip's mount pad. 20.80 14.80 0.80 12.00 0.10 0.10 0.80 0.05 0.45 0.05 0.80 0.05 Unit: Figure Recommended Dimensions Mount 0.80 12.00 0.10 Dimensions User System Interface Cable Head dimensions user system interface cable head shown figure Figure Dimensions User System Interface Cable Head Resulting Dimensions after Connecting User System Interface Cable resulting dimensions, after connecting user system interface cable head user system, shown figure User system socket (IC149-064-008-B5 manufactured YAMAICHI ELECTRONICS Co., Ltd.) Unit: Tolerance: Figure Resulting Dimensions after Connecting User System Interface Cable Section Installing User System CAUTION Check location before inserting. Phillips-type screwdriver whose head matches screw head. tightening torque must 0.0784 less. applied torque cannot accurately measured, stop tightening when force required turn screw becomes significantly greater than that needed when first tightening. screw tightened much, screw head break socket contact error caused crack socket solder. does operate correctly, cracks might have occurred solder. Check conduction with tester re-solder socket necessary. Check location before inserting into socket user system, shown figure After inserting MCU, fasten socket cover with provided four screws (M2.0 mm). Take special care, such manually securing socket soldered area, prevent socket from being damaged overtightening screws twisting components. Socket cover mark socket (IC149-064-008-B5 manufactured YAMAICHI ELECTRONICS Co., Ltd.) User system Figure Installing User System Section Verifying Operation When using H8/300 series E6000 emulator (HS3008EPI60H), turn emulator according procedures described H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). Verify user system interface cable connections accessing external memory ports check states pins. error detected, recheck soldered socket location emulator connected this user system interface cable supports kinds clock sources: emulator internal clock external clock user system. details, refer H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). emulator internal clock Select clock emulator station system clock using CLOCK command (emulator command). external clock user system system clock Select target clock with CLOCK command (emulator command). Supply external clock from user system emulator. Connect crystal oscillator EXTAL XTAL terminals system clock. system clock same frequency external clock. Figure shows oscillator circuit user system interface cable. HCU04 HCU04 E6000 emulator EXTAL XTAL System clock Figure Oscillator Circuit Section Notice Make sure that user system socket correctly aligned with cable head before inserting cable head into user system socket. dimensions recommended mount user system socket different from those MCU. This user system interface cable specifically designed HS3008EPI60H emulator. this cable with other emulator station. prevent breaking wires cable body, place heavy sharp metal objects user system interface cable. While emulator station connected user system with user system interface cable, force must applied cable head. Place emulator station, user system interface cable, user system shown example figure Figure User Cable Location Example short connector used testing. remove inserted jumper pin. Figure Short Connector Other recent searchesSMV2070A-LF - SMV2070A-LF SMV2070A-LF Datasheet RH128128T-1X5WN-B - RH128128T-1X5WN-B RH128128T-1X5WN-B Datasheet RH176220L-2X0NN-O - RH176220L-2X0NN-O RH176220L-2X0NN-O Datasheet PD8670A - PD8670A PD8670A Datasheet AOZ8013 - AOZ8013 AOZ8013 Datasheet AD9552 - AD9552 AD9552 Datasheet 2SC3686 - 2SC3686 2SC3686 Datasheet
Privacy Policy | Disclaimer |