| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
User's Manual HS3297ECS61HE(C) Renesas neither warrants gran
Top Searches for this datasheetH8/3297 Series, H8/329 Series SDIP-64 User System Interface Cable (HS3297ECS61H) E6000 Emulator User's Manual HS3297ECS61HE(C) Renesas neither warrants grants licenses rights Renesas's third party's patent, copyright, trademark, other intellectual property rights information contained this document. Renesas bears responsibility problems that arise with third party's rights, including intellectual property rights, connection with information contained this document. Products product specifications subject change without notice. Confirm that have received latest product standards specifications before final design, purchase use. Renesas makes every attempt ensure that products high quality reliability. However, contact Renesas's sales office before using product application that demands especially high quality reliability where failure malfunction directly threaten human life cause risk bodily injury, such aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment medical equipment life support. Design your application that product used within ranges guaranteed Renesas particularly maximum rating, operating supply voltage range, heat radiation characteristics, installation conditions other characteristics. Renesas bears responsibility failure damage when used beyond guaranteed ranges. Even within guaranteed ranges, consider normally foreseeable failure rates failure modes semiconductor devices employ systemic measures such fail-safes, that equipment incorporating Renesas product does cause bodily injury, fire other consequential damage operation Renesas product. This product designed radiation resistant. permitted reproduce duplicate, form, whole part this document without written approval from Renesas. Contact Renesas's sales office questions regarding this document Renesas semiconductor products. Preface Thank purchasing E6000 emulator Renesas's original microprocessor H8/300 series. HS3297ECS61H user system interface cable that connects H8/300 series E6000 emulator (HS3008EPI60H; hereinafter referred emulator) socket SDIP64 package (package code: DP-64S) H8/3297 series H8/329 series user system. Contents Section Configuration.1 Section Connection Procedures Connecting User System Interface Cable Emulator Station Connecting User System Interface Cable User System 2.2.1 Installing Socket 2.2.2 Inserting Cable Head 2.2.3 Connecting Cable Body Cable Head Dimensions User System Interface Cable Head. Resulting Dimensions after Connecting User System Interface Cable Section Verifying Operation.10 Section Notice Section Configuration CAUTION IC83-64075-GS4 socket (manufactured YAMAICHI ELECTRONICS Co., Ltd.) DP-64S package socket user system. Figure shows configuration HS3297ECS61H user system interface cable DP-64S package. emulator station Cable body Cable head socket User system Figure HS3297ECS61H User System Interface Cable Table lists HS3297ECS61H components. Please make sure have these components when unpacking. Table HS3297ECS61H Components Quantity protection DP-64S package User's manual HS3297ECS61H (this manual) Remarks Includes flat cable Component Cable body Cable head sockets Documentation Section Connection Procedures Connecting User System Interface Cable Emulator Station WARNING Always switch user system emulator product before USER SYSTEM INTERFACE CABLE connected removed from part. Before connecting, make sure that both sides correctly aligned. Failure will damage user system emulator product will result PERSONAL INJURY. USER PROGRAM will LOST. connect cable body emulator station, follow instructions below. Make sure user system emulator station turned off. After making sure direction cable body connector correct, firmly insert cable body connector into emulator station socket (figure Emulator station Cable body User system interface cable Figure Connecting User System Interface Cable Emulator Station Connecting User System Interface Cable User System WARNING Always switch user system emulator product before USER SYSTEM INTERFACE CABLE connected removed from part. Before connecting, make sure that both sides correctly aligned. Failure will damage user system emulator product will result PERSONAL INJURY. USER PROGRAM will LOST. connect cable head user system, follow instructions below. 2.2.1 Installing Socket Prepare socket (commercially available) DP-64S package mount user system. Recommended socket: IC83-64075-GS4 manufactured YAMAICHI ELECTRONICS Co., Ltd. 2.2.2 Inserting Cable Head CAUTION Check location before inserting. Align socket DP-64S package user system with user system interface cable head, insert user system interface cable head into socket user system, shown figure Cable head User system socket (IC83-64075-GS4 manufactured YAMAICHI ELECTRONICS Co., Ltd.) Figure Connecting User System Interface Cable User System 2.2.3 Connecting Cable Body Cable Head Connect cable body cable head. Cable body Removing Push remove Remove Cable head User system Figure Fastening Cable Body Dimensions User System Interface Cable Head dimensions user system interface cable head shown figure 68.6 21.6 45.7 16.2 63.5 10.6 57.7 Unit: Tolerance: ±0.5 Figure Dimensions User System Interface Cable Head 78.7 Resulting Dimensions after Connecting User System Interface Cable resulting dimensions, after connecting user system interface cable head user system, shown figure Cable head User system socket* mounted user system sockets* protection Note: IC83-64075-GS4 manufactured YAMAICHI ELECTRONICS Co., Ltd. Figure Resulting Dimensions after Connecting User System Interface Cable 12.0 Unit: Tolerance: ±0.5 Section Verifying Operation When using H8/300 series E6000 emulator (HS3008EPI60H), turn emulator according procedures described H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). Verify user system interface cable connections accessing external memory ports check states pins. error detected, recheck soldered socket location emulator connected this user system interface cable supports kinds clock sources: emulator internal clock external clock user system. details, refer H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). emulator internal clock Select clock emulator station system clock using CLOCK command (emulator command). external clock user system system clock Select target clock with CLOCK command (emulator command). Supply external clock from user system emulator. Connect crystal oscillator EXTAL XTAL terminals system clock. H8/3297 series, system clock same frequency external clock, H8/329 series, system clock half frequency external clock. Figure shows oscillator circuit user system interface cable. HCU04 HCU04 E6000 emulator EXTAL XTAL System clock Figure Oscillator Circuit Section Notice Make sure that user system socket correctly aligned with cable head before inserting cable head into user system socket. This user system interface cable specifically designed HS3008EPI60H emulator. this cable with other emulator station. prevent breaking wires cable body, place heavy sharp metal objects user system interface cable. While emulator station connected user system with user system interface cable, force must applied cable head. Place emulator station, user system interface cable, user system shown example figure User system Figure User Cable Location Example short connector used testing. remove short pins that inserted sides Figure Short Connector Other recent searchesMT9074 - MT9074 MT9074 Datasheet FSD1000 - FSD1000 FSD1000 Datasheet BFCN-1855+ - BFCN-1855+ BFCN-1855+ Datasheet AAT3244 - AAT3244 AAT3244 Datasheet
Privacy Policy | Disclaimer |