The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

User's Manual HS3297ECS61HE(C) Renesas neither warrants gran


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



H8/3297 Series, H8/329 Series SDIP-64 User System Interface Cable (HS3297ECS61H) E6000 Emulator
User's Manual
HS3297ECS61HE(C)
Renesas neither warrants grants licenses rights Renesas's third party's patent, copyright, trademark, other intellectual property rights information contained this document. Renesas bears responsibility problems that arise with third party's rights, including intellectual property rights, connection with information contained this document. Products product specifications subject change without notice. Confirm that have received latest product standards specifications before final design, purchase use. Renesas makes every attempt ensure that products high quality reliability. However, contact Renesas's sales office before using product application that demands especially high quality reliability where failure malfunction directly threaten human life cause risk bodily injury, such aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment medical equipment life support. Design your application that product used within ranges guaranteed Renesas particularly maximum rating, operating supply voltage range, heat radiation characteristics, installation conditions other characteristics. Renesas bears responsibility failure damage when used beyond guaranteed ranges. Even within guaranteed ranges, consider normally foreseeable failure rates failure modes semiconductor devices employ systemic measures such fail-safes, that equipment incorporating Renesas product does cause bodily injury, fire other consequential damage operation Renesas product. This product designed radiation resistant. permitted reproduce duplicate, form, whole part this document without written approval from Renesas. Contact Renesas's sales office questions regarding this document Renesas semiconductor products.
Preface
Thank purchasing E6000 emulator Renesas's original microprocessor H8/300 series. HS3297ECS61H user system interface cable that connects H8/300 series E6000 emulator (HS3008EPI60H; hereinafter referred emulator) socket SDIP64 package (package code: DP-64S) H8/3297 series H8/329 series user system.
Contents
Section
Configuration.1
Section Connection Procedures
Connecting User System Interface Cable Emulator Station Connecting User System Interface Cable User System 2.2.1 Installing Socket 2.2.2 Inserting Cable Head 2.2.3 Connecting Cable Body Cable Head Dimensions User System Interface Cable Head. Resulting Dimensions after Connecting User System Interface Cable
Section Verifying Operation.10 Section Notice
Section
Configuration
CAUTION
IC83-64075-GS4 socket (manufactured YAMAICHI ELECTRONICS Co., Ltd.) DP-64S package socket user system.
Figure shows configuration HS3297ECS61H user system interface cable DP-64S package.
emulator station
Cable body
Cable head
socket User system
Figure HS3297ECS61H User System Interface Cable
Table lists HS3297ECS61H components. Please make sure have these components when unpacking. Table HS3297ECS61H Components
Quantity protection DP-64S package User's manual HS3297ECS61H (this manual) Remarks Includes flat cable
Component Cable body Cable head sockets Documentation
Section Connection Procedures
Connecting User System Interface Cable Emulator Station
WARNING
Always switch user system emulator product before USER SYSTEM INTERFACE CABLE connected removed from part. Before connecting, make sure that both sides correctly aligned. Failure will damage user system emulator product will result PERSONAL INJURY. USER PROGRAM will LOST.
connect cable body emulator station, follow instructions below. Make sure user system emulator station turned off. After making sure direction cable body connector correct, firmly insert cable body connector into emulator station socket (figure
Emulator station
Cable body User system interface cable
Figure Connecting User System Interface Cable Emulator Station
Connecting User System Interface Cable User System
WARNING
Always switch user system emulator product before USER SYSTEM INTERFACE CABLE connected removed from part. Before connecting, make sure that both sides correctly aligned. Failure will damage user system emulator product will result PERSONAL INJURY. USER PROGRAM will LOST.
connect cable head user system, follow instructions below. 2.2.1 Installing Socket
Prepare socket (commercially available) DP-64S package mount user system. Recommended socket: IC83-64075-GS4 manufactured YAMAICHI ELECTRONICS Co., Ltd.
2.2.2
Inserting Cable Head
CAUTION
Check location before inserting.
Align socket DP-64S package user system with user system interface cable head, insert user system interface cable head into socket user system, shown figure
Cable head
User system
socket (IC83-64075-GS4 manufactured YAMAICHI ELECTRONICS Co., Ltd.)
Figure Connecting User System Interface Cable User System
2.2.3
Connecting Cable Body Cable Head
Connect cable body cable head.
Cable body Removing Push remove
Remove
Cable head
User system
Figure Fastening Cable Body
Dimensions User System Interface Cable Head
dimensions user system interface cable head shown figure
68.6
21.6
45.7 16.2 63.5
10.6
57.7
Unit: Tolerance: ±0.5
Figure Dimensions User System Interface Cable Head
78.7
Resulting Dimensions after Connecting User System Interface Cable
resulting dimensions, after connecting user system interface cable head user system, shown figure
Cable head
User system
socket* mounted user system
sockets* protection
Note: IC83-64075-GS4 manufactured YAMAICHI ELECTRONICS Co., Ltd.
Figure Resulting Dimensions after Connecting User System Interface Cable
12.0
Unit: Tolerance: ±0.5
Section Verifying Operation
When using H8/300 series E6000 emulator (HS3008EPI60H), turn emulator according procedures described H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). Verify user system interface cable connections accessing external memory ports check states pins. error detected, recheck soldered socket location emulator connected this user system interface cable supports kinds clock sources: emulator internal clock external clock user system. details, refer H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). emulator internal clock Select clock emulator station system clock using CLOCK command (emulator command). external clock user system system clock Select target clock with CLOCK command (emulator command). Supply external clock from user system emulator. Connect crystal oscillator EXTAL XTAL terminals system clock. H8/3297 series, system clock same frequency external clock, H8/329 series, system clock half frequency external clock. Figure shows oscillator circuit user system interface cable.
HCU04
HCU04 E6000 emulator
EXTAL
XTAL
System clock
Figure Oscillator Circuit
Section Notice
Make sure that user system socket correctly aligned with cable head before inserting cable head into user system socket. This user system interface cable specifically designed HS3008EPI60H emulator. this cable with other emulator station. prevent breaking wires cable body, place heavy sharp metal objects user system interface cable. While emulator station connected user system with user system interface cable, force must applied cable head. Place emulator station, user system interface cable, user system shown example figure
User system
Figure User Cable Location Example short connector used testing. remove short pins that inserted sides
Figure
Short Connector

Other recent searches


MT9074 - MT9074   MT9074 Datasheet
FSD1000 - FSD1000   FSD1000 Datasheet
BFCN-1855+ - BFCN-1855+   BFCN-1855+ Datasheet
AAT3244 - AAT3244   AAT3244 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive