| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
S-35L12A S-35L12A CMOS real-time clock which designed transfer ea
Top Searches for this datasheetREAL-TIME CLOCK S-35L12A S-35L12A CMOS real-time clock which designed transfer each data clock calendar requested CPU. S-35L12A interfaced with three wires. systems interrupt/alarm function kHz-fixed clock output make easy develop process software side host computer. also works lower power with oscillating circuit operated constant voltage. Features power consumption Wide area operating voltage :0.55 typ. (VDD=3.0 Ta=25°C) :1.3 (1.65 with power voltage detection circuit built-in) input/output year, month, day, week, hour, minute second interface three wires Auto calender till year 2,099 (automatic leap year arithmetic feature included) Built-in power voltage detecting circuit Built-in constant voltage circuit Built-in flag generating circuit power on/off Built-in alarm interrupter (two systems) kHz-fixed clock output Steady-state interrupt frequency/duty setting feature Built-in crystal oscillating circuit (Internal External Applications Cellular phone variety pagers Camera Package 10-Pin SSOP (pin pitch (Package drawing code FS010-A) Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Block Diagram Clock generating circuit Rev.1.3_00 XOUT F32K Oscillating circuit Timing generation INT1 Register Comparator INT1 week Status register Second Minute Hour Month Year Power voltage detecting circuit Constant voltage circuit Comparator INT2 Clock generating circuit INT2 Register Shift register Serial Interface Figure Seiko Instruments Inc. Rev.1.3_00 Product Code Structure S-35L12AE Package name (abbreviation) 10-Pin SSOP10 Description (fixed) REAL-TIME CLOCK S-35L12A Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Assignment Package: S-35L12AEFS Rev.1.3_00 10-pin SSOP view INT1 XOUT F32k Figure S-35L12AECA INT2 INT1 XOUT F32K S-35L12A INT2 Remark size 1.94 1.58 Sizes shown design purposes only. corners shrink approximately after dicing. size Chip rear area potential Coordinates Y-Coordinate Symbol -375 -631 Figure INT2 Symbol INT1 XOUT F32k X-Coordinate -811 -811 -811 -811 -811 X-Coordinate Y-Coordinate -209 -631 Seiko Instruments Inc. Rev.1.3_00 Description Pins Table Symbol INT1 Description REAL-TIME CLOCK S-35L12A Configuration XOUT F32K Alarm interrupt output pin. Depending mode INT1 open drain output register status register, outputs protective diode side Clock when time reached. disabled VDD) rewriting status register. Crystal oscillator connect (32,768 (Internal External Negative power supply (GND) 32,768 clock output open drain output protective diode side VDD) open drain output protective diode side VDD) INT2 Alarm interrupt output pin. Depending mode INT2 register status register, outputs Clock when time reached. disabled rewriting status register. Chip select input pin. During allows data input/output. allows data input. During Hi-Z state. inputdisabled state. Serial clock input pin. input/output data from performed synchronization with this clock. However, clock accepted while "L". Serial data input/output pin. normally Hi-Z state while "L". When changes from "H", input pin. will input output pin, depending subsequently input command. Positive power supply pin. CMOS input (internal pulldown resistance. protective diode side VDD) CMOS input protective diode side VDD) open drain output protective diode side VDD) CMOS input Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Absolute Maximum Ratings Item Symbol Table Applicable pin, conditions Rating Rev.1.3_00 Unit Power voltage VSS-0.3 VSS+4.0 Input voltage Applied SCK,SIO VSS-0.3 VSS+4.0 Output voltage VOUT Applied SIO,INT1, INT2 VSS-0.3 VSS+4.0 +125 Storage temperature Tstg Caution absolute maximum ratings rated values exceeding which product could suffer physical damage. These values must therefore exceeded under conditions. Recommended Operating Conditions Item Power voltage Operating temperature Symbol Table Condition Min. Typ. Max. Unit Topr Oscillation Characteristics Table (Unless otherwise specified Ta=25°C, VDD=3 DS-VT-200 (crystal oscillator, CL=6 32,768 manufactured Quartz Techno Ltd.) Item Oscillation start voltage Oscillation start time IC-to-IC frequency diversity Frequency voltage diversity Input capacity Output capacity Symbol VSTA TSTA VDD=3 Condition Within seconds VDD=1.3 Applied Applied XOUT Min. Typ. Max. Unit ppm/V Seiko Instruments Inc. Rev.1.3_00 Electrical Characteristics Table characteristics REAL-TIME CLOCK S-35L12A (Unless otherwise specified Ta=25°C, VDD=3 DS-VT-200 (crystal oscillator, CL=6 32,768 manufactured Quartz Techno Ltd.) Item Operating voltage range Current consumption Current consumption Input leak current Input leak current Input current Input current Output leak current1 Output leak current2 Input voltage Input voltage Output current Output current Power voltage detection voltage Power voltage detection voltage Symbol IDD1 IDD2 IIZH IIZL IIL1 IIL2 IOZH IOZL IOL1 IOL2 VDET1 VDET2 Applicable SCK, SCK, INT1, INT2 INT1, INT2 SIO, SCK, SIO, SCK, INT1, INT2 Condition +70°C During communications During communications (SCK=100 kHz) VIN=VDD VIN=VSS VIN=3.6 VIN=0.4 VOUT=VDD VOUT=VSS VOUT=0.4 VOUT=0.4 Ta=+25°C +70°C Min. -0.5 -0.5 -0.5 -0.5 1.15 Typ. 0.55 1.45 Max. 0.85 1.65 Unit Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Electrical Characteristics (S-35L12A, RL=10 CL=80 Rev.1.3_00 Table characteristics Conditions VDD=1.3 Ta=-20 70°C Input; VIH=0.8 VDD, VIL=0.2 Output; VOH=0.8 VDD, VOL=0.2 (VCC=3.0 Item Clock pulse width Setup time before rising Hold time after rising Input data setup time Input data hold time Output data definition time Setup time before falling Hold time after falling Symbol tSCK tCSH tISU tIHO tACC tCSS Min. Typ. Max. 250000 Unit Input rising/falling time Caution Since output form open drain output, rising time tACC determined values load resistance (RL) load capacity (CL) outside this reference value. Table characteristics Conditions VDD=3.0 Ta=-20 70°C Input; VIH=0.8 VDD, VIL=0.2 Output; VOH=0.8 VCC, VOL=0.2 (VCC=3.0 Item Clock pulse width Setup time before rising Hold time after rising Input data setup time Input data hold time Output data definition time Setup time before falling Hold time after falling Symbol tSCK tCSH tISU tIHO tACC tCSS Min. Typ. Max. 250000 Unit Input rising/falling time 0.05 Caution Since output form open drain output, rising time tACC determined values load resistance (RL) load capacity (CL) outside this reference value. Seiko Instruments Inc. Rev.1.3_00 Timing Chart REAL-TIME CLOCK S-35L12A tCSH tCSS Figure tISU tIHO Input Data Figure tSCK tSCK tACC Output Data Figure Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Description Operation Serial interface Rev.1.3_00 S-35L12A receives various commands 3-wire serial interface read/write data. This section covers transfer methods this product. Communication data configuration After turning "H", send 4-bit fixed code "0110" succeedingly transfer command 3-bit length read/write command 1-bit length. Fixed code Command Read/Write Figure Communication data Command configuration There eight types commands which read from write various registers. table below lists them. command that listed table provides operation. Table Command list Description Reset (year), (month), (day), (day week), (minute), (second)) Status register access Real-time data access (year data Real-time data access (hour data Alarm time/frequency duty setting (for INT1 pin) Alarm time/frequency duty setting (for INT2 pin) Test mode start Test mode Don't care this command. This command access-disabled specific test. Data reading When input data from synchronization with falling after turning "H", data included S-35L12A eighth rising clock state data reading reached when "1". state leads output data corresponding each command synchronization with falling subsequent clock input. Remark When number clocks less than eight, state clock waiting reached processing done. When clocks more than required, they processed order from first clocks other than those required ignored. Seiko Instruments Inc. Rev.1.3_00 Real-time data reading REAL-TIME CLOCK S-35L12A TEST Command Year data Output mode switching Second data Input mode switching Real-time data reading TEST Command Hour data Output mode switching Second data Input mode switching Status register reading POWER Command Output mode switching Status data Input mode switching Figure Read communication Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Rev.1.3_00 Data writing When input data from synchronization with falling after turning "H", data included into inside S-35L12A eighth rising clock state data writing reached when "0". state, data written registers according each command synchronization with falling subsequent clock input. Real-time data writing TEST Command Year data Second data Real-time data writing TEST Command Hour data Second data Status register writing POWER Command Status data Figure Write communication Seiko Instruments Inc. Rev.1.3_00 Register configuration REAL-TIME CLOCK S-35L12A Real-time data register real-time data register 56-bit register which stores code data year, month, day, week, hour, minute second. read/write operation performed real-time data access command sends receives data from first digit year data. Year data Sets lower digits year links together with auto calendar feature until 2,099. Year Flag (YF) count value when changing date from 59:23, Dec. 1999 00:00, Jan. 2000. reset, year data 2000s 1900s because automatically reset. Month data count value automatically changed auto calender feature: (leap year): (common year): data week data septenary counter. that corresponds week. Hour data AM/PM 12-hour expression, 0:AM 1:PM. 24-hour expression, this flag meaning either must written. Minute data TEST Second data test flag TEST Turns during test mode. Figure Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Rev.1.3_00 Status register status register 8-bit register which allows display various modes. POWER flag read-only others read/write-enabled. POWER 12/24 INT1AE INT2AE INT1ME INT2ME INT1FE INT2FE Figure B7:POWER This flag turns power voltage detecting circuit operates during power-on changes power voltage (below VDET). Once turning "1", this flag does turns back even when power voltage reaches exceeds detection voltage. When flag "1", must send reset command status register read command) turn "0". read-only flag. This flag used 12-hour 24-hour expression. 12-hour expression 24-hour expression B6:12/24 B5:INT1AE, B4:INT2AE This flag used choose state INT1 INT2 pin) output with alarm interrupt output set. Enable this flag after setting alarm time that forms meeting condition INT1 register INT2 register): Alarm interrupt output disabled. Alarm interrupt output enabled. B3:INT1ME, B2:INT2ME This flag used make output INT1 INT2 pin) per-minute edge interrupt per-minute steady interrupt. make output per-minute steady interrupt, INT1ME INT1FE INT2ME INT2FE). Alarm interrupt selected frequency steady interrupt output Per-minute edge interrupt per-minute steady interrupt output B1:INT1FE, B0:INT2FE This flag used make output INT1 INT2 pin) per-minute steady interrupt output period minute, duty) selected frequency steady interrupt. Note that INT1 register (INT2 register) considered data frequency/duty selected frequency steady interrupt chosen. Alarm interrupt per-minute edge interrupt output Per-minute steady interrupt selected frequency steady interrupt output Seiko Instruments Inc. Rev.1.3_00 REAL-TIME CLOCK S-35L12A Alarm time/Frequency duty setting register There types alarm time/frequency duty setting registers, 16-bit registers, which alarm time frequency duty. They switched INTxAE INTxFE register. AM/PM flag must accordance with 12-hour 24-hour expression. AM/PM flag rightly then hour data alarm data. alarm time/frequency duty setting register write-only register. When INTxAE INT1 register Figure INT1 register (alarm) INT2 register Figure INT2 register (alarm) INT1 INT2 registers considered alarm time data. Having same configuration time minutes registers real-time data register configuration, they represent hours minutes with codes. When setting them, none-existent day. Data must accordance with 12-hour 24-hour expression that status register. Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Rev.1.3_00 When INTxFE INT1 INT2 registers considered frequency duty data. turning each registers "1", frequency corresponding each chosen ANDed form. INT1 register INT2 register 32768 16384 8192 4096 2048 1024 Figure INT1 INT2 registers (frequency/duty) Seiko Instruments Inc. Rev.1.3_00 Example 000A REAL-TIME CLOCK S-35L12A INT1 INT2 terminal output selected frequency steady interrupt output Figure Clock output Test flag test flag 1-bit register which assigned second data real-time data register. transferred data considered test mode starting command receiving test mode starting command noises, set. When set, must send test mode ending command reset command. Initialization Note that S-35L12A different initializing operations, depending states. When power turned When power turned status register "82h" INT1 register "8000h" power-on detecting circuit. other words, (POWER flag) status register clock output from INT1 pin. This provided adjust oscillating frequencies. normal use, reset command must sent when power turned Real-time data register (year), (month), (day), (day week), (hour), (minute), (second) (year flag: "1") Status register "82h" INT1 register "8000h" INT2 register "0000h" When power voltage detecting circuits operates power voltage detecting circuit included S-35L12A operates sets (POWER flag) internal status register when power turned power voltage reduced. Once set, held even after power voltage gets equal higher than detection voltage, i.e., power voltage detector threshold. When flag "1", must send reset command from initialize flag. this point, other registers change, however, POWER flag during power-on reset (S-35L12A does reach indefinite area during backup), have send reset command. Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A When reset command received When reset command received, each register turns follows: Rev.1.3_00 Real-time data register (year), (month), (day), (day week), (hour), (minute), (second) (year flag "1") Status register "00h" INT1 register "0000h" INT2 register "000h" POWER flag command data status read command command Don't care status data reset command LINE POWER flag backup state (S-35L12A does reach indefinite POWER flag command data command LINE down POWER flag status read command status data real-time data read Figure Initializing Seiko Instruments Inc. Rev.1.3_00 Processing none-existent data end-of-month REAL-TIME CLOCK S-35L12A When writing real-time data, validate treat invalid data end-of-month correction. [None-existent data processing] Table Register Normal data Error data Result Year data Month data data week data Hour data (24-hour) (12-hour) Minute data Second data 12-hour expression, write AM/PM flag AM/PM flag ignored 24-hour expression, o'clock o'clock read read operation. None-existent data processing second data performed carry pulse second after writing. this point, carry pulse sent minute counter. [End-of-month correction] none-existent corrected first next month. example, February changed March Leap-year correction also performed here. Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Interrupt Rev.1.3_00 There different five output formats from INT1 INT2 pin, which chosen INTxAE, INTxME INTxFE bits status register (x:1 Alarm interrupt output Alarm interrupt enabled setting hour minute data INT1 register INT2 register) turning status register's INT1AE INT1ME INT1FE INT2AE INT2ME INT2FE "0"). When hour data met, output from INT1 INT2 pin). Since output held, rewrite INT1AE INT2AE) status register through serial communication turn output high (OFF state). coincidence signal when minute changes from seconds second outputs signal from INT1 INT2 pin). When perform disable enable communication within coincidence period minute), attention that INT1 INT2 pin) remains "High" level (OFF state). Selected frequency steady interrupt output When frequency/duty data INT1 register INT2 register) turn status register's INT1ME INT1FE INT2ME INT2FE "1"), clock INT1 register INT2 register) output from INT1 INT2 pin). Per-minute edge interrupt output When first minute carry performed after status register's INT1ME with INT1FE with INT2ME with INT2FE with "0"), output from INT1 INT2 pin). Since output held, rewrite INT1AE, INT1ME INT1FE INT2AE, INT1ME INT2FE) status register through serial communication turn output high (OFF state). When perform disable enable communication while minute carry processing signal being retained (for µs), signal output from INT1 INT2 pin) again. Per-minute steady interrupt output When first minute carry performed after status register's INT1ME INT1FE with INT2ME INT2FE with "1"), clock output from INT1 INT2 pin) with period minute (50% duty). When perform disable enable communication while INT1 INT2 pin) "L," signal output from INT1 INT2 pin) again. Caution changing output mode, give care state INT1and INT2 registers output. per-minute edge interrupt output per-minute steady interrupt output chosen, INT1 INT2 registers have meaning. Seiko Instruments Inc. Rev.1.3_00 REAL-TIME CLOCK S-35L12A Note INT1AE INT2AE INT1ME INT2ME Table Interrupt description INT1FE Description INT2FE INT1 output disabled interrupt output) Selected frequency steady interrupt output from INT1 Per-minute edge interrupt output from INT1 Per-minute steady interrupt output from INT1 Alarm interrupt output from INT1 Description INT2 output disabled interrupt output) Selected frequency steady interrupt output from INT2 Per-minute edge interrupt output from INT2 Per-minute steady interrupt output from INT2 Alarm interrupt output from INT2 Don't care (both available) Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Alarm interrupt output hour minute (n-2) (n-1) (n+1) (m-1) (m+1) Rev.1.3_00 INTxAE INTxME=INTxFE=0 INTx Change program Once alarm time reset, signal generates even when enable within conincidence time. Alarm time corresponds Alarm time corresponds Selected frequency steady interrupt output Change program INTxFE INTxAE=INTxME=0 INTx Free output starts Per-minute edge interrupt output Change program INTxME INTxAE=INTxFE=0 signal output again case less Minute-carry processing Minute-carry processing Per-minute steady interrupt output Change program (OFF) INTxFE,INTxME INTxAE=0 INTx Minute-carry processing Minute-carry processing Minute-carry processing Minute-carry processing Minute-carry processing signal output again case less. signal output case more. signal output next minute-carry processing. During power-on detecting circuit operation Change reset command INTxFE INTxAE=INTxME=0 INT1 INT2 state Figure Output mode Seiko Instruments Inc. Rev.1.3_00 Power voltage detecting circuit REAL-TIME CLOCK S-35L12A S-35L12A internal power voltage detecting circuit. This circuit gives sampling movement only 15.6 once second. power voltage decreases below detection voltage (VDET), latch circuit latches level, sampling movement stops. Only when subsequent communication status read command, output latch circuit transferred sift register sampling movement resumed. Decrease power voltage monitored reading POWER flag. That say, once decrease power voltage detected, detecting operation performed held unless perform initialization send status read command. Caution When power voltage increased first read operation performed after decrease power voltage occurs latch circuit latches "H", read POWER flag, however, next read operation performed after sampling detecting circuit, POWER flag reset since sampling subsequently allowed. timing diagram below. VDET Communication Sampling pulse Stop Stop Stop Latch circuit output POWER flag VDET Communication Sampling pulse Stop Stop Stop Stop Latch circuit output POWER flag [Timing sampling pulse] Carry pulse Sampling pulse Latch timing 15.6 Carry-up timing Figure Timing power voltage detecting circuit Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Example software treatment Initialization flow power-on START Rev.1.3_00 Power S-35L12A back-up power turned only side, reset command does need transferring. POWER Reset command transfer conditions good (e.g., noise) probable changes commands occurs serial communications, recommended make sure TEST flag. test ending command used alternately. TEST=1 Reset command transfer Status register setting command transfer Real-time data setting command transfer INTx register setting command transfer Figure Initialization flow Seiko Instruments Inc. Rev.1.3_00 Samples Application Circuits S-35L12A INT1 INT2 XOUT External REAL-TIME CLOCK S-35L12A System power with protective diode side, relation VCCVDD problem give great care standard. Make communications after system power turned stable state obtained. Figure Application circuit Power switching circuit S-35L12A INT1 INT2 External System power XOUT Make communications after system power turned stable state obtained. Figure Application circuit Caution application circuits above guarantee proper operation. Evaluate actual application determine correct constants Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Adjustment Oscillating Frequency Configuration oscillating circuit Rev.1.3_00 Since crystal oscillation sensitive external noises (clock accuracy affected), following measures essential optimizing your oscillating circuit configuration: Place S-35L12A, crystal oscillator external capacitor (Cg) close each other possible. Make high insulation resistance between pins substrate wiring patterns XOUT. place signal power lines close oscillating circuit. XOUT Crystal oscillator:32.768 CL=6 Cg=3 Oscillating circuit internal constant standard values: Rf=20 Rd=220 Cd=12 S-35L12A Figure Connection diagram Seiko Instruments Inc. Rev.1.3_00 Measurement oscillating frequencies REAL-TIME CLOCK S-35L12A When power turned S-35L12A internal power-on detecting circuit operating outputs signal from INT1 select crystal oscillator optimize value. Turn power measure signal with frequency counter following circuit configuration shown Figure Remark error range relation time shifted approximately seconds month calculated using following expression) (1ppm) seconds minutes hours days 2.592 seconds XOUT INT1 Open Open INT2 Frequency counter S-35L12A Figure Connection diagram Caution high-accuracy frequency counter order). Since signal continues output, must send reset command normal operation. Determine with frequency slow/fast range property referred. Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Adjustment oscillating frequencies Rev.1.3_00 Matching crystal oscillator with nominal frequency must performed with parasitic capacitance board included. Select crystal oscillator optimize value accordance with flow chart below. START Select crystal oscillator. Variable capacity <Trimer capacitor> <Fixed capacitor> center variable capacitor. specification Does frequency match Change optimal value Make fine adjustment frequency variable capacity. Figure Crystal oscillation setting flow making matching adjustment with crystal, contact appropriate crystal maker determine value (load capacity) value (equivalent serial resistance). value value typ. recommended values. value selection must performed actual since parasitic capacitance affects Select value range from frequency does match, change value crystal. Adjust rotation angle variable capacity that capacity value somewhat smaller than center, confirm oscillating frequency center value variable capacity. This done order make capacity center value smaller than half actual capacity value because smaller capacity value makes greater quantity changes frequency. frequency does match, change value crystal. Caution Oscillating frequencies changed ambient temperature power voltage. Refer property samples. crystal oscillator operates slower higher lower ambient temperature than 25°C. Therefore, recommended adjust oscillator operate somewhat faster normal temperature. Seiko Instruments Inc. Rev.1.3_00 Precautions REAL-TIME CLOCK S-35L12A apply electrostatic discharge this that exceeds performance ratings built-in electrostatic protection circuit. claims responsibility disputes arising connection with infringement products including this patents owned third party. Seiko Instruments Inc. REAL-TIME CLOCK S-35L12A Characteristics (Reference Data) Standby current 0.75 IDD1 [µA] 0.25 0.25 [pf] Operating current consumption Input clock Ta=25°C IDD2 [µA] 1,000 frequency [kHz] Oscillating frequency [ppm] [pf] Ta=25°C 0.25 VDD=3 IDD1 [µA] 0.75 VDD=3 IDD1 [µA] Ta=25°C Standby current 1.25 0.75 Cg=7 Rev.1.3_00 Ta=25°C Standby current temperature VDD=3 Cg=7 [°C] Oscillating frequency Ta=25°C [ppm] VDD=3 Seiko Instruments Inc. Rev.1.3_00 Oscillating frequency temperature Ta=25°C, VDD=3 REAL-TIME CLOCK S-35L12A Oscillation start time Ta=25°C VDD=3 [ppm] -120 -160 [°C] Output current (VOUT IOL1) INT1 INT2 pin, Ta=25°C TSTA [mS] [pf] (10) Output current (VOUT OL2) pin, Ta=25°C IOL1 [mA] VDD=3 IOL2 [mA] VDD=3 VOUT VOUT Seiko Instruments Inc. 3.1±0.3 0.15 -0.05 +0.1 0.50 0.2±0.1 FS010-A-P-SD-1.1 TITLE SCALE UNIT SSOP10-A-PKG Dimensions FS010-A-P-SD-1.1 Seiko Instruments Inc. 1.55±0.05 4.0±0.1 2.0±0.05 0.3±0.05 8.0±0.1 1.55±0.05 1.4±0.1 (4.0) 6.9±0.1 Feed direction FS010-A-C-SD-1.1 TITLE SCALE UNIT SSOP10-A-Carrier Tape FS010-A-C-SD-1.1 Seiko Instruments Inc. 13.5±0.5 Enlarged drawing central part 2±0.5 2±0.5 13±0.2 21±0.8 FS010-A-R-SD-1.1 TITLE SCALE UNIT SSOP10-A-Reel FS010-A-R-SD-1.1 QTY. 2,000 Seiko Instruments Inc. information described herein subject change without notice. Seiko Instruments Inc. responsible problems caused circuits diagrams described herein whose related industrial properties, patents, other rights belong third parties. application circuit examples explain typical applications products, guarantee success specific mass-production design. When products described herein regulated products subject Wassenaar Arrangement other agreements, they exported without authorization from appropriate governmental authority. information described herein other purposes and/or reproduction copying without express permission Seiko Instruments Inc. strictly prohibited. products described herein cannot used part device equipment affecting human body, such exercise equipment, medical equipment, security systems, equipment, apparatus installed airplanes other vehicles, without prior written permission Seiko Instruments Inc. Although Seiko Instruments Inc. exerts greatest possible effort ensure high quality reliability, failure malfunction semiconductor products occur. user these products should therefore give thorough consideration safety design, including redundancy, fire-prevention measures, malfunction prevention, prevent accidents, fires, community damage that ensue. Other recent searchesTS617 - TS617 TS617 Datasheet SBL10B60CTH - SBL10B60CTH SBL10B60CTH Datasheet NJU6060 - NJU6060 NJU6060 Datasheet NJU6060V - NJU6060V NJU6060V Datasheet LAA120L - LAA120L LAA120L Datasheet KDS8333C - KDS8333C KDS8333C Datasheet CYV15G0104TRB - CYV15G0104TRB CYV15G0104TRB Datasheet BB621R - BB621R BB621R Datasheet BB622R - BB622R BB622R Datasheet ATA6623 - ATA6623 ATA6623 Datasheet ATA6625 - ATA6625 ATA6625 Datasheet ISO7637 - ISO7637 ISO7637 Datasheet
Privacy Policy | Disclaimer |