| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
chassis- PCB-mounting SCHAFFNER Your number name Single
Top Searches for this datasheetSINGLE PHASE FILTERS chassis- PCB-mounting SCHAFFNER Your number name Single-phase filters chassis- PCB-mounting CONTENTS General information Introduction single-phase filters Filter selection chart Understanding standards filter specifications.4 measurement engineering services Ordering information.9 Technical data 352Z.22 700Z.50 9675 Mechanical Data Addresses contact information SCHAFFNER Powerline filters vital element today's electronic designs today's world, more electrical energy being generated increasing levels power, more more power energy being used transmission processing data. result vastly increased `electronic smog' noise. This noise disrupt, even destroy, electronic devices: unacceptable situation, shortly illegal certain markets. electronics industry must strive protect equipment against such `noise'. Noise, interference, travels ways. Switches such semiconductors emit interference, susceptible same true data processing equipment. most common method protection powerline filters coupled with screening gasketting materials. mains, powerline, filter element eliminating mains-borne interference. This filter only meet requirements electro-magnetic compatibility (EMC), safety aspects well. some applications, filter also prevent radiation classified information from mains line (`Tempest' applications). Other applications require filter protect equipment from destructive voltages power line, like those caused lightning nuclear explosion (NEMP). Schaffner's breadth product range, high attenuation characteristics filters under various load conditions, dedication quality above organization's unique experience filter design manufacturing spanning more than years your guarantee excellence. testing. ensure high quality have instituted system which meets stringent requirements 9001 29001. phrase `Quality Assurance' just slogan applied practice, Schaffner brand truly stands reliability quality. Schaffner's single-phase filter range provides off-the-shelf solution vast majority electronic equipment noise problems. standard product range particularly wide, embracing both chassis-mounting PCB-mounting types, allowing users select optimal choice both performance cost efficiency terms. mounting version (see following section), inlet type which typically handle currents 6-10A ideal small office industrial equipment. associated specification safety requirement computer office/business equipment, developed provide consistent world standard, which turn simplifies certification process. standard specifies requirements intended ensure safety against electrical fire hazards operator layman come into contact with equipment, where specifically stated, service personnel. 950-compliance required products shipped Europe, either already become process becoming de-facto standard other world markets. been adopted European countries under EN60950, under 1950. filter families this catalogue available with inlets, which compliant with (request separate inlet/IEC catalogue full details Schaffner's range). Chassis-mount types general, chassis mount filters provide higher performance solution, metal cases optimum connection earth good high frequency performance. With space available three circuit stages attenuation noise, users usually find option with performance provide shelf solution even most difficult problems retrofit solution existing design instance). Schaffner offers chassis-mounting versions very wide range power levels from less than covering majority higher power office equipment medium power industrial applications. lower power levels, users have additional choice opting PCB- PCB-mount types filters designed compactness ease assembly, avoid need extra mounting components installation operations necessary with chassis styles, expense finite available space filtering circuitry. Consequently, they typically offer just single stage attenuation, with limitations maximum power handling capability 6.5A current ratings). This typically makes these filters ideal those companies have planned protection throughout equipment design process, completing equipment protection with these cost components. When designing these components care needs taken provide impedance connection earth, minimize potential noise Total commitment quality Schaffner's provide customers with faultfree products. achieve this, 100% products undergo rigorous final radiation from mains inlet connection. Schaffner's single-phase products with brief details parameters will help identify more filters closer review specifications (there some options available total range). From this initial selection, review circuit diagram detailed specifications following pages will tell module suitable your application, allowing choose unit units) trial. Schaffner world's leading suppliers equipment, extensive experience allows offer widest filtering ranges available spanning both generalpurpose specialist needs like TEMPEST. This breadth range greatly assists designers, allowing optimum choices made, whether need maximum performance lowest cost. worldwide organization with numerous application engineering teams will gladly help your engineers select trial suitable power line filters, provides efficient support structure assist multi-national organizations with dispersed design manufacturing facilities. review this catalogue will show you, Schaffner designs power line filters using high grade components order optimize reliability. construct modules under control most advanced quality system. Whichever power line filter choose, rely Schaffner's quality. Time market reasons choosing ready-made filters convenience, compactness cost. Although design your mains inlet filter using discrete components, have custom solution designed assembled you, timescales involved getting safety approvals will often rule this approach out, especially higher volume products such photocopiers which necessitate very fast design cycles. Ready-made chassis- PCB-mount filters provide convenient single-source solution, with additional benefits custom-engineered housings compactness. following guide Schaffner's chassis- PCB-mounting filter range Rapid selection Using current rating attenuation performance indicators, together with major features shown right, this table allows quickly identify `short list' filter families which potentially suitable your application, subsequent detailed investigation using technical specifications following pages. with earth line choke printed-circuit mounting with overvoltage protection current rating medical equipment NEMP, TEMPEST Attenuation Filter family 250, 352Z .406 610, 660, 680, 700Z 9675/76 standard middle high very high motor drives with inlet SMPS stage stage Understanding standards filter specifications This section introduces standards regulations associated with protection, provides detailed information help understand filter design specifications. will help identify your application right specifications type filter. Interference protection standards Until recently most countries have their regulations standards governing electro-magnetic interference (EMI) radio frequency interference (RFI). However, January 1992 European Directive 89/336/EMC electro-magnetic compatibility (EMC) came into force. This directive brings common approach every member state European Union. Common standards will used throughout Europe ensure that technical trade barriers removed. well controlling emissions from equipment, directive also calls equipment immune external electro-magnetic disturbances. task elaborating standards used been given European organisation called CENELEC. member countries CENELEC are: Austria Belgium Denmark Finland France Germany Greece Iceland Ireland Italy Luxembourg Netherlands Norway Portugal Spain Sweden Switzerland United Kingdom Product type Emissions Harmonics Voltage fluctuations Household appliances EN60555-2 EN60555-3 portable tools: vacuum cleaners, washing machines, heating, cooking equipment, dimmers Luminaires with discharge lamps receivers Information Technology Equipment (ITE) Mains signalling equipment Industrial, scientific medical eqpt. designed generate energy Industrial electronic power control equipment Industrial non-electronic equipment Radio interference Immunity aspects Once European standard complete individual members European Union will produce national harmonised standards will usually give their harmonised standard national number, British harmonised standard 55011 55011. Permissible noise limits various standards down limits conducted emissions. These limits measured voltage given dBµV where 1µV. interference measured using measurement equipment which defined bandwidths receivers. receivers used quasi-peak detector, average detector. ensure repeatability measurements, impedance mains supply must constant. standards calls defined artificial mains network sometimes called line impedance stabilisation network (LISN) which gives defined impedance noise also helps filter noise mains which affect measurements. Figure shows limits 50081-1 European generic standard residential, commercial light industrial environments, Figure 50081-2, European generic standard industrial environment. Above 30MHz, radiated noise interference measured instead conducted noise. This takes place open field test site using defined antennas. Types standards: Basic standards describe general fundamental rules meeting requirements. Terminology, phenomena, compatibility levels, measurement, test techniques classification environments described within. Generic standards refer specific environments. They minimal levels which equipment these environments must meet. Where product specific standards exist then generic standards used. Generic standards describe household industrial environments. Products standards specific products product groups. These standards coordinated with generic standards. countries outside Europe other standards will used, such USA. Table shows main European standards. EN55014 EN50082-1 EN60555-2 EN60555-2 EN60555-2 EN55015 EN55013 EN55022 EN50065-1 EN55011 EN50082-1 EN55020 EN55024 parts EN50082-2 EN50082-2 Most European standards will based upon international standards from CISPR IEC. numbering system used European standards European Norm. denotes that standard standard CENELEC origin; means standard based CISPR standard yyy; means standard based standard yyy. EN50081-2 EN50082-2 EN50081-2 producing interference) Table European standards Level (dBµV) Quasi-peak Average Level (dB) flow along phase returns along another phase (Figure Common mode noise creates voltage between each phase earth. common mode currents flow from noise source earth (usually parasitic capacitance) along earth path returns along phases. (See Figure power line filter must designed attenuate both common mode differential mode interference. LIGHT INDUSTRIAL DOMESTIC 0.15 Frequency (MHz) Frequency (Hz) Frequency Figure Permissible interference limits 50081-1 Figure Discrete spectrum Interference propagation propagate means: Level (dBµV) Quasi-peak Average radiation where energy coupled either through magnetic electric field, electro-magnetic wave between source victim conduction where energy will propagate along power supply lines data cables Radiated conducted cannot thought totally separate problems, because noise conducted along cable radiated cable acts antenna. radiation will increase cable length becomes comparable wavelength noise. Also, cable will receiving antenna pick radiated interference. Below around 150MHz, most efficient radiating devices system usually power supply data cables. Proper filtering these cables will reduce radiation cables well conducted interference. Above around 150MHz, tracks short internal cables will start become efficient antennas. reduce this radiation should laid reduce track length loop areas; ground planes should used possible. Decoupling digital very important shielding necessary. Line Neutral Earth INDUSTRIAL 0.15 Frequency (MHz) Figure 50081-2 limits Figure Differential mode interference (VDM) Interference sources spectrums most common source conducted power electronic products such switched mode power supplies (SMPS), pulse width modulated (PWM) frequency converters motor drives, phase angle controllers. emissions spectrum typically starts very large frequency rolls frequency increases. point which noise falls below permitted limits depends several factors, most important being frequency operation rise time semiconductor devices. Interference spectrums generated either continuous, case phase angle controllers, (Figure discrete which typical SMPS (Figure Level Pegel (dB) Line Neutral Earth Figure Common mode interference (VCM) Mains filters Maximum power transfer occurs when source load impedances matched. power line filter inductor-capacitor network that aims cause maximum mismatch between impedances, therefore reduces amount power transferred from noise source onto power line cable. Figure shows typical single-phase power line filter. Interference types understand problems associated with conducted first necessary understand modes conducted noise: differential mode symmetrical mode) common mode asymmetrical mode). Differential mode interference creates voltage between phases system independent earth; differential mode currents Live Line Neutral Earth Frequency (Hz) Frequency Frequenz Figure Continuous spectrum Figure typical single-phase power line filter inductors usually wound current compensated fashion toroidal core. This winding method allows flux differential mode currents mains currents cancel each other, while common mode currents will added together. This gives large inductance common mode currents ensures that inductor will saturated large magnetic flux produced mains current. capacitors placed between phases, known class capacitors must offer high pulse voltage rating used attenuate differential mode interference. capacitors between phase lines earth, known class capacitors must have more stringent rating used attenuate common mode interference. value capacitor restricted permissible leakage current allowed. maximum leakage current governed standards regulations depends upon type equipment. leakage current given IL=2 where leakage current; voltage across capacitor; frequency mains voltage across capacitor, capacitance. Mains filters should mounted close possible power entry that high frequency interference does bypass filter. inlet modules ideally suited this task. achieve higher attenuation increase effective working frequency range more complex filters than shown Figure made using more common mode differential mode inductors capacitors. `CISPR Measurements', document published Schaffner available request. test condition, sets insertion loss curves given. common (asymmetrical) mode insertion loss. other differential mode interference. general, Schaffner filters perform against common mode interference manner shown insertion loss tests. differential mode, representative effective performance. Therefore Schaffner includes 0.1/100 differential mode test show filter will perform real life situations. this 0.1/100 test condition, only differential mode insertion loss given. this test, mismatched impedances illustrate effective filter performance piece equipment. Both types insertion loss testing carried without load current. equipment under load, inductance therefore insertion loss change saturation. allow this Schaffner measures inductance variation with current. typical filter inductance variation shown Figure CISPR17, and/or application note `Everything wanted know provide more detailed information. temperature 40°C. Current other temperatures shown derating curve, ascertained formula: )/45 Voltage ratings maximum rated voltage 250V 50/60Hz unless otherwise stated individual datasheets. capacitors within Schaffner filters which conform permit operation voltages above this value. High voltage testing high voltage rating filters devided into specifications, type testing production testing. This accordance with guidelines laid down various recommendations. Type testing shall minimum 2121 minimum seconds between terminals. However, discharge resistor inside filter shall removed this test according recommendations. values given this catalogue 100% production tests minimum seconds. Repetition voltage tests shall exceed specified values. Leakage current leakage current ground each type given maximum value phase, 230V/50Hz. Safety approvals Filters this catalogue approved major world safety approval agencies. Each datasheet indicates current safety approval status. relevant file numbers filters are: E64388 44788 Test: 1283 Test: 22.2 8-M1986 Test: Insertion loss insertion loss characteristics each filter shown datasheets, measured accordance with CISPR test conditions employed: using termination impedances, other using input impedance output impedance (and reverse conditions). Both test methods found section CISPR Figure Typical saturation curve 7226-4730-10. Test: 0565-3 SEMKO Test: General technical data technical data given unless otherwise specified. Almost filters this catalogue meet requirements Class Class installations with Basic Supplementary Insulation. further information Schaffner's application note `IEC 950'. Current ratings current ratings given each type maximum allowable current authorised safety agencies ambient Flammability class filters this catalogue 94V2 UL94V0. MTBF figures addition safety approvals, Schaffner filters also have high reliability shown MTBF (mean time between failure) values given each filter family. This lowest typical value filter particular family calculated according Mil-HB 217-F, maximum rated current voltage ambient temperature 40°C. MTBF stated hours. Components component values given detailed product pages nominal. value inductors capacitors vary from this nominal value. tolerance test conditions these components shown following table: Parameter Inductance Capacitance Resistance Tol. Tol. Test 1kHz 1kHz number: Humidity, 90-95% R.H. days Filters with greater temperature range, special applications military use, available request. magnetic fields, feed lines these areas protected with voltage limiting devices such varistors, discharge tubes suppressor diodes. Special filters TEMPEST Telecommunication data processing equipment radiate signals, propagate them along power lines, providing mechanism unauthorised persons access classified information. study blocking such sensitive signals known TEMPEST. Mains filters with high attenuation over large frequency range necessary. optimum filter solution only found exact specification requirements. 700Z filter series been used many TEMPEST applications. Other suitable filters available request. Filters with earth line chokes possible interference induced cables system simultaneously. this case same noise will also induced onto earth cable. standard filter will reduce noise phase lines earth. noise earth line will then able enter equipment cause equipment malfunction. reduce this interference earth line chokes fitted incorporated into filter. earth line choke will also provide extra attenuation normal common mode currents. Care must taken bypass earth line chokes systems. example have filter with earth line choke fitted, this connected printer that powered from mains supply, printer does have earth line choke, noise find path from mains into printer along data cable into bypassing earth line choke Customer-specific filters Schaffner's standard range filters cover majority customers' requirements. depending application, specific criteria might need considered. With many years experience, well flexibility capability five development centers located throughout world, Schaffner offer companies efficient reliable custom engineering service. date, Schaffner produced over 4000 custom filters, ranging from amps 1200 amps, from matchbox size rack mount designs, with input connections, used forms environments from offices submarines factories military armoured vehicles. Climatic classification Schaffner filters fulfil requirements climatic classification according 40040 (ambient temperature +85°C). Filters with connecting cable such types meet requirements climatic classification (ambient temperature +70°C). letters climatic classification coded follows: letter: Lower temperature limit: -25°C letter: Upper temperature limit: +70°C +85°C letter: Permissible humidity (relative): yearly average highest value days highest other days According Part climatic category given three numbers, separated Sample: 25/085/21 Filters medical equipment enhanced safety medical applications, Schaffner offers versions many filters, offering lower leakage current (3µA typical), discharge resistor, higher potential test values (for example 326B). Special filters NEMP nuclear electro-magnetic pulse (NEMP) high intensity, short duration, electromagnetic field produced result nuclear explosion outside atmosphere (exo-atmospheric). most critical threat technically highly developed nations exo-atmospheric burst altitude more than producing NEMP inducing antennas, power transmission networks etc, such high voltages currents that leave whole continent without power, telephone radio communications. Electronic equipment protected against NEMP placed special room housing which screen from electro- number: Lower temperature limit: -25°C number: Upper temperature limit: +85°C SCHAFFNER measurement engineering services addition offering world's most comprehensive ranges standard filter products, Schaffner offers full complement measurement engineering services support equipment manufacturers users. Expert Support testing Schaffner operates most sophisticated test facilities available anywhere today with extensive investment screened rooms, specialist test equipment, application engineering teams distributed seven locations throughout world. Services available these locations include: Faraday cage open field testing harmonics instrumentation current voltage 49th harmonic radio emission measurements CISPR, VDE, FCC, simulation electro-magnetic fields simulation short-term mains failures simulation transient parasitic voltages electro-static discharges 801-2, 0843 part specifications insulation testing Engineering services Schaffner largest world engineering experience solving problems. addition testing measuring services Schaffner provide expert engineering support help bring your equipment market quickly efficiently; services available include: custom filter design optimize filter performance, solve space, layout, mounting connection problems circuit equipment design advising circuit equipment enclosure design overcome problems turnkey component design build SCHAFFNER Ordering information single-phase filters (except connections solder-lug mounting clamp terminal with screw fast-on solder-lug/fast-on combination wire screw feed-through fast-on mini fast-on clamp terminal terminal block terminal block fast-on details mechanical data pages current rating leakage (small capacitors) medical version (without capacitors) surge voltage protection filter type Examples: 670-1.8/07 Type 670; current rating 1.8A; with wire connections 350-55/33 Type 350; current rating 55A; with safety terminal block connections SCHAFFNER Compact PCB-mounting filter Provided compact plastic housing suitable with automatic assembly equipment, this PCB-mounting filter offers good basic performance, with profile which suits equipment designs such monitors, terminals power supplies. compact PCB-mounting design auto-insertion machine friendly Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine component value. Approvals Family Connections Current ratings Capacitance Inductance Housing Weight 40°C (25°) -0.8 -0.8 (0.95) (0.95) Additional specifications Filter type Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage µA/phase 50/60 2000 1700 Standard types MTBF 40°C, 230V, Mil-HB-217F: 2,750,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 22-0.8/2 types 100k 22-0.8/3 types 100k Electrical schematics 2xCy LOAD LINE tables component values. SCHAFFNER Input filter motor drives High inductance capacitance values optimized common mode attenuation 0.1-1MHz range make this filter ideal large variety motor drive applications. Long wire connections give great installation flexibility, simplifying assembly drive manufacturers. current ratings compact housings with long wire connections meets EN55011(A) drives with motor cables <20m Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 250-6/07 filter with wire connections. Approvals Family Connections Current ratings Capacitance Res. 40°C (25°) (6.9) (13.8) (23) Cx/Cx1 0.47/0.47 2.2/2 0.47 0.47 0.22 Power loss Inductance Housing Weight Additional specifications Filter type Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage µA/phase Standard types 1300 50/60 2000 1100 MTBF 40°C, 230V, Mil-HB-217F: 295,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types types 100k types 100k Electrical schematics LINE 2xCy LOAD tables component values. SCHAFFNER Performance filter Designed suppressing high interference levels, this filter available wide choice current ratings, also optional version with varistor protection against high surge voltages. current ratings compact housing with solder fast-on connections optional surge voltage protection types) Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 332-6/01 filter with solder connections. Approvals Family Connections Current ratings Inductance Housing Weight 40°C (25°) (1.2) (3.6) (7.3) (12) -10A Additional specifications Filter type Capacitance Surge Energy current absorption Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Standard types 332Z types (surge protected) 1200 µA/phase 2000 2000 1700 50/60 50/60 MTBF 40°C, 230V, Mil-HB-217F: 710,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types types types 100k 100k 100k types 100k Electrical schematics LINE 2xCy LOAD LINE 332Z 2xCy LOAD tables component values. SCHAFFNER Two-stage filter general-purpose filter with two-stage design integral earth line choke high performance with good common mode attenuation. current ratings 2-stage design with earth line choke Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 343-3/01 filter with solder connections. Approvals Family Connections Current ratings (1.15) (3.4) (6.9) (11.5) Inductance L/L1/L2 Housing Weight 5.6/10/0.4 1.1/2/0.4 0.43/0.77/0.4 0.27/0.66/0.4 Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Cx/Cx1 Standard types 100/100 µA/phase 50/60 2000 1700 MTBF 40°C, 230V, Mil-HB-217F: 970,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types types types 100k 100k 100k types 100k Electrical schematics 2xL1 2xCy tables component values. LOAD LINE SCHAFFNER High-performance filter This filter offers 320-compliant power entry with excellent filtering performance thanks U-core plus large inductor capacitor components. Very high symmetrical attenuation makes filter ideal choice switched-mode power supply equipment applications, other form circuitry involving non-sinusoidal waveforms. current ratings very high performance filtering optional medical versions types) Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 346-10/06 filter with fast-on connections. Approvals Family Connections Current ratings Inductance Housing Weight 40°C (25°) -1.6 -2.5 (1.9) (7.3) (12) Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Cx/Cx1 Standard types types (medical) 470/220 470/220 0.47 0.47 µA/phase 2000 2000 1700 1700 50/60 50/60 MTBF 40°C, 230V, Mil-HB-217F: 330,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types types types types Electrical schematics LINE 2xCy LOAD tables component values. SCHAFFNER High power filter drives High inductance capacitance values optimized common differential mode attenuation lower frequency range make this filter ideal large variety motor drive applications. Supplied relatively small footprint design with terminal blocks easy installation servicing industrial environments; also meets extending applications flexibility. current ratings screwdriver-connect terminations meets EN55011/14/22 0871/75/78 meets Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 350-55/33 filter with terminal connections suitable 6/16mm2 wire. Approvals Family Connections Current ratings Capacitance Inductance (9.2) (13.8) (23) (34.5) (63) Cx/Cx1 Cy/Cy1 2/0.68 2.2/1 2.2/1 2.2/1 4.4/1 10/47 10/47 10/47 15/47 33/94 Maximum leakage Power loss Housing Weight µA/phase 4900 4900 4900 5300 1800 Additional specifications Filter type Maximum operating voltage Operating frequency Hipot test voltage Standard types 50/60 2800 1700 MTBF 40°C, 230V, Mil-HB-217F: 420,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k types Electrical schematics LINE 2xCy 2xCy1 tables component values. LOAD SCHAFFNER Multi-stage filter This filter family provides high performance two- three-stage circuit design with varistor protection against high surge voltages 2000A. 353Z version packages same circuit design around differential mode core greater compactness. current ratings integral surge voltage protection solder screwdriver connections 352Z Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 352Z-6/06 filter with fast-on connections. Approvals Family Connections Current ratings Capacitance Res. Inductance 352Z 352Z 352Z 353Z (7.2) (12) (20) (30) Cx/Cx1 Cy/Cy1 L/L1/L2 3/3/5/0.06/0.003 3.5/0.06/0.0035 2.3/0.025/0.035 Maximum leakage Housing Weight µA/phase 1300 1300 1300 1320 2950 3100 470/220 3.3/1.5 0.47 220/220 220/220 470/220 15/15 15/15 15/15 0.47 0.47 0.23 Additional specifications Filter type Energy absorption Maximum operating voltage Operating frequency Hipot test voltage Standard types 50/60 2000 MTBF 40°C, 230V, Mil-HB-217F: 230,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k Electrical schematics 352Z-6 LINE 2xCy LOAD LOAD 352Z-10/FN 352Z-20/FN 353Z-30 2xL1 2xL2 LINE tables component values. SCHAFFNER Two-stage filter motor drives This two-stage filter offers good low-to-medium power performance aimed frequency ranges encountered typical motor drive applications, also lower frequency (sub 100kHz) equipment. Terminal blocks simplify installation servicing. current ratings screwdriver-connect terminations meets EN55011/14/22 0871/75/78 Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 357-10/29 filter with terminal connections suitable 10/6mm wire. Approvals Family Connections Current ratings Capacitance Res. Inductance (6.9) (11.5) (18.4) Cx/Cx1 Cy/Cy1 1.5/2.2 2.2/2.2 22/22/33 47/47 0.075 L/L1 3.5/0.75 2.8/0.45 2.3/0.4 Maximum leakage Power loss Housing Weight µA/phase 3800 4800 8100 1450 1500 3000 Additional specifications Filter type Maximum operating voltage Operating frequency Hipot test voltage Standard types 50/60 2800 1100 MTBF 40°C, 230V, Mil-HB-217F: 250,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k Electrical schematics (6A) 2xL1 16A) 2xL1 LOAD 2xCy 2xCy 2xCy 2xCy1 tables component values. LOAD LINE LINE SCHAFFNER Performance PCB-mount filter Offering excellent filtering with high component values good asymmetric common mode attenuation, suitable demanding applications such switched-mode power supplies, this filter supplied low-profile plastic PCB-mount package choice power ratings. 0.8-1.5A current ratings compact PCB-mount footprint profile design Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 401-1.5/02 1.5A filter with connections. Approvals Family Connections Current ratings Capacitance Res. Inductance Housing Weight -0.8 -1.5 (0.95) (1.8) Additional specifications Filter type Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage µA/phase 50/60 2000 1100 Standard types MTBF 40°C, 230V, Mil-HB-217F: 1,000,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types 100k Electrical schematics (0.8A) LINE 2xCy LOAD LINE (1.5A) 2xCy LOAD tables component values. SCHAFFNER Low-cost PCB/chassis-mount filter Provided very compact profile PCB- chassis-mounting plastic enclosure, with choice current ratings four output connections, this filter combines great versatility with economy. 0.5-6.5A current ratings compact PCB- chassis-mountable design four connection style choices very profile optional medical versions types) Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 402-4/16 filter with mini fast-on connections. Approvals Family Connections Current ratings Inductance Housing Weight -0.5 -1.6 -2.5 -6.5 /07* /07* /07* /07* /07* /07* (0.6) (1.2) (1.9) (3.0) (4.7) (7.5) KA/KB KA/KB KA/KB KA/KB KA/KB KA/KB outputs weight Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Standard types types (medical) µA/phase 50/60 50/60 2000 2500 1700 1700 MTBF 40°C, 230V, Mil-HB-217F: 1,900,000 hours. (standard types); 1,200,000 hours types) Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k types types 100k 100k Electrical schematics LINE LOAD LINE 402B LOAD tables component values. SCHAFFNER PCB-mounting filter General-purpose filter mounting applications, supplied plastic housing. 0.5-6A current ratings PCB-mounting profile Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 405-6/02 filter with connections. Approvals Family Connections Current ratings Inductance Housing Weight 40°C (25°) -0.5 (0.6) (1.2) (3.6) (6.9) Additional specifications Filter type Capacitance Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Standard types µA/phase 50/60 2000 1100 MTBF 40°C, 230V, Mil-HB-217F: 1,600,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k Electrical schematics LINE 2xCy LOAD tables component values. SCHAFFNER Ultra-compact filter PCB-mounting filter offers high performance exceptionally compact form, ideal equipment applications where space premium. With footprint just greatly reduces area required compared with using discrete components, with height profile which does exceed capacitors transformers typically used circuitry such switched mode power supplies. Performance also enhanced, thanks aluminium housing providing excellent shielding protect against coupling effects from nearby components. 0.5-6A current ratings aluminium case very compact PCB-mounting design profile Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 406-6/02 filter with connections. Approvals Family Connections Current ratings Inductance Housing Weight -0.5 (0.6) (1.2) (3.5) (6.9) 0.78 Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Standard types types (medical) µA/phase 50/60 50/60 2000 2500 1700 1700 MTBF 40°C, 230V, Mil-HB-217F: 1,900,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k Electrical schematics LINE 2xCy LOAD LINE 406B LOAD tables component values. SCHAFFNER Two-stage filter This filter, with two-stage inductor design, offers high attenuation metal-cased PCB-mounting form. 0.5-6A current ratings high attenuation 2-stage design PCB-mounting Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 410-6/02 filter with connections. Approvals Family Connections Current ratings Inductance Housing Weight 40°C (25°) -0.5 (0.6) (1.2) (3.6) (6.9) L/L1 24/24 10/10 0.8/0.8 Additional specifications Filter type Capacitance Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Standard types µA/phase 50/60 2000 1700 MTBF 40°C, 230V, Mil-HB-217F: 675,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k Electrical schematics LINE 2xL1 LOAD tables component values. SCHAFFNER Versatile easy-mount filter This low-cost filter supplied flat case with rounded edges, making easy mount almost location great versatility problem solving. medium-performance filter design aimed generalpurpose applications. 0.6-6.5A current ratings profile case designed easy-mounting Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 422-4/13 filter with mini fast-on connections. Approvals Family Connections Current ratings Inductance 40°C (25°) -0.6 -2.5 -6.5 (0.7) (1.2) (4.8) (7.3) 22.5 0.75 Filter type Capacitance Res. types types types Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Housing Weight µA/phase 50/60 50/60 50/60 2000 2000 2000 1700 1700 1700 MTBF 40°C, 230V, Mil-HB-217F: 625,000 hours. Electrical schematics LINE 2xCy LOAD tables component values. 420/422 LINE 2xCy LOAD Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types 100k types 100k types types 100k 100k types 100k types types 100k 100k types 100k types types 100k 100k types 100k types types 100k 100k SCHAFFNER General-purpose filter This family designed provide economic solution many general-purpose filtering requirements. Available over versions, with current ratings from with choice four different styles connections, application requirements easily economically matched. current ratings from general-purpose filtering performance four choices connector style optional medical version types) optional safety version types) Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 610-10/06 filter with fast-on connections. Approvals (10A max. Semko) Family Connections Current ratings Inductance Housing Weight 40°C (25°) (1.15) (3.4) (6.9) (11.5) (23) (34) 0.75 0.45 0.48 0.61 Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Standard types types (safety) types (medical) 0.47 µA/phase 2000 2500 2500 1700 1700 1700 50/60 50/60 50/60 MTBF 40°C, 230V, Mil-HB-217F: 1,200,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k types types 100k 100k types) 100k types) types) 100k 100k Electrical schematics LINE types) 2xCy LOAD 100k 610A LINE 610B 2xCy LOAD LINE LOAD tables component values. SCHAFFNER General-purpose filter Like 610, with additional capacitance improved differential mode performance, this family designed provide economic solution many general-purpose filtering requirements. Available numerous versions, with current ratings from with choice four different styles connection, application requirements easily economically matched. current ratings from good differential mode attenuation four choices connector optional medical versions type) Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 612-1/06 filter with fast-on connections. Approvals Family Connections Current ratings Inductance Housing Weight 40°C (25°) (1.15) (3.4) (6.9) (11.5) (23) (34) 0.75 0.45 0.48 0.61 Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Standard types types (medical) µA/phase 2000 2500 1700 1700 50/60 50/60 MTBF 40°C, 230V, Mil-HB-217F: 800,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k types types 100k 100k Electrical schematics 2xCy tables component values. LOAD LINE SCHAFFNER Two-stage general-purpose filter Like 612, with additional inductance stage higher common mode attenuation, this family designed provide economic solution many general-purpose filtering requirements. Available versions, with current ratings from with choice four different styles connection, application requirements easily economically matched. current ratings from high differential common mode attenuation four choices output connector optional medical versions type) Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 660-3/07 filter with wire connections. Approvals (16A max. VDE) Family Connections Current ratings Inductance L/L1 Housing Weight 40°C (25°) (1.15) (3.4) (6.9) (11.5) (18.4) (23) 0.75/0.75 0.45/0.45 0.44/0.44 0.48/0.48 Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Standard types types (medical) µA/phase 2000 2500 1700 1700 50/60 50/60 MTBF 40°C, 230V, Mil-HB-217F: 350,000 hours (for VDE-approved current ratings). Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k types types 100k 100k Electrical schematics LINE 2xCy 2xL1 LOAD tables component values. SCHAFFNER Two-stage performance filter Like 660, with even higher component values excellent common- differential- mode attenuation especially high frequencies, this family designed provide economic solution broadband filtering requirements. Available versions, with current ratings 10A, filters ideal with precision instrumentation, switched-mode power supplies motor drives. current ratings from very high differential common mode attenuation good high frequency attenuation Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 670-3/06 filter with fast-on connections. Approvals Family Connections Current ratings Inductance L/L1 Housing Weight 40°C (25°) -1.8 (1.8) (10) 7.2/7.2 12.2/1.8 10.4/2.7 Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Cx/Cx1 Standard types 470/150 0.47 µA/phase 2000 1700 50/60 MTBF 40°C, 230V, Mil-HB-217F: 300,000 hours (for VDE-approved current ratings). Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k Electrical schematics LINE 2xCy 2xL1 LOAD tables component values. SCHAFFNER Two-stage performance filter Like 670, with improved component values core excellent attenuation frequencies including ranges, this generalpurpose filter excellent choice protecting against very high levels interference, such noisy power supplies. Available versions, with current ratings from 10A, application requirements easily economically matched. current ratings from very high differential common mode attenuation good frequency attenuation Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 682-4/07 filter with wire connections. Approvals Family Connections Current ratings Inductance L/L1 Housing Weight 40°C (25°) (1.2) (4.8) (7.8) (12) 22.5/1.2 16/0.27 8/0.08 4.1/0.055 4/0.04 -2.5 -6.5 Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage types types (4A) types (6.5-10A) 1000 0.33 0.47 µA/phase 2000 2000 2000 1700 1700 1700 1900 1900 50/60 50/60 50/60 MTBF 40°C, 230V, Mil-HB-217F: 1,400,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k types 100k Electrical schematics 680/682 LINE 2xL1 2xCy tables component values. LOAD SCHAFFNER High-power performance filter Like 680, with even higher inductance values excellent common- differential- mode attenuation especially high frequencies, this family designed provide solution broadband filtering requirements. Available versions, with current ratings 36A, filters ideal with switched-mode power supplies, computers other digital systems. current ratings from excellent attenuation characteristics Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 685-10/06 filter with fast-on connections. Approvals Family Connections Current ratings Inductance Housing Weight 40°C (25°) (12) (19.2) (30) (43.2) L/L1 4.2/40 2.3/0.04 1.35/0.04 0.8/0.03 1200 1350 2350 2850 Additional specifications Filter type Capacitance Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Cx/Cx1 types types 470/220 470/220 0.33 0.33 µA/phase 2000 2000 1700 1700 1900 50/60 50/60 MTBF 40°C, 230V, Mil-HB-217F: 400,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types types 100k 100k types 100k Electrical schematics 685/686 LINE 2xL1 2xCy LOAD tables component values. SCHAFFNER Three-stage filter Offering outstanding noise suppression frequencies 3GHz, together with protection against nuclear electromagnetic pulses very high surge voltages, this filter provides ready-to-use option highintegrity equipment designs. Applications include systems requiring TEMPEST NEMP protection, overcoming sensitive interference problems with commercial equipment. 700Z current ratings from options with inlets) TEMPEST NEMP attenuation 3GHz protection against high surge voltages Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 700Z-20/03 filter with screw clamp connections. Approvals Family Connections Current ratings Inductance Housing Weight 40°C (25°) 700Z (6.9) (11.6) (23) 0.33 0.33 0.33 17.1 2000 2300 3500 700Z 700Z Additional specifications Filter type Capacitance Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage Cx/Cx1 6A/10A types types 1/1/2.2 Cy/Cy1 2.5/5/10 µA/phase 2600 50/60 50/60 MTBF 40°C, 230V, Mil-HB-217F: 450,000 hours. Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types types types Electrical schematics 700Z-6, 700Z-10 2xCy 2xL1 2xCy 2xL1 700Z 2xCy 2xCy1 2xCy1 2xL1 2xCy 2xL1 tables component values. LOAD LINE LOAD LINE SCHAFFNER Compact performance filter This one-stage filter constructed using novel winding technique, provide kind performance usually found only more expensive two-stage designs. Consequently, excellent choice solving more difficult interference problems, where equipment space premium, such high-density switched-mode power supplies. current ratings from economic high-performance filter screw fast-on connections 9675 Mechanical Data (pages full details housings connections. Filter selection table Choose family with required current rating features, determine input/output (line/load) connection style. Example: 9675-3/06 filter with fast-on connections. Approvals Family Connections Current ratings Inductance Capacitance Housing Weight 40°C (25°) 9675 9675 9675 9676 (3.5) (6.9) (18.4) (18.4) 10.2 10.2 Cx/Cx1 680/680 680/680 1000/1000 1000/1000 1050 Additional specifications Filter type Capacitance Cy/Cy1 Res. Maximum leakage Maximum operating voltage Operating frequency Hipot test voltage 0.47 0.47 µA/phase 2000 2000 1700 1700 9675 types 9676 types 4.7/6.8/15 1900 50/60 50/60 MTBF 40°C, 230V, Mil-HB-217F: 280,000 hours 9675); 400,000 hours 9676). Insertion loss CISPR 50/50 sym, 50/50 asym, 0.1/100 sym, 100/0.1 types 100k types 9675 100k 100k 9676 100k Electrical schematics 9675 LINE 2xCy LOAD LINE 2xCy LOAD 2xCy LINE 2xCy1 LOAD 9675 (16A) 9676 (16A) tables component values. Mechanical Data Housing SCHAFFNER 420, Tol.* 10.16 7.62 7.62 7.62 1.27 65.8 15.2 Measurements share this common tolerance unless otherwise stated. BOTTOM VIEW BOTTOM VIEW SIDE VIEW SIDE VIEW Housing Housing Housing Housing SIDE VIEW SIDE VIEW VIEW VIEW Housing Housing Housing Housing Mechanical Data 357-6, Housing SCHAFFNER 352Z-20 353Z-30 352Z-10 357-16 350-55 352Z-6 Tol.* 150.5 55.25 100.5 -0.4 119.5 Measurements share this common tolerance unless otherwise stated. SIDE VIEW FRONT VIEW Housing (Connection /29) Housing (Connection /33) Housing Housing (Connection /33) Housing B7A, (Connection /03) VIEW VIEW Housing B7A, B11, B13, B21, Housing Mechanical Data 700Z-6 Housing SCHAFFNER 700Z-20 700Z-10 Tol.* 112.5 112.5 75.9 -0.3 55.6 Measurements share this common tolerance unless otherwise stated. FRONT VIEW FRONT VIEW FRONT VIEW Housing B24, Housing BACK VIEW BOTTOM VIEW Housing B24, Housing SIDE VIEW BOTTOM VIEW VIEW Housing B24, Housing Housing Mechanical Data -1-3-6 Housing SCHAFFNER -3-6-10 610-10 612-1 660-1 680-1 Tol.* 24.8 12.5 18.7 46.6 50.5 10.5 16.5 24.5 29.5 46.6 50.5 21(J1) (J2) 10.5 52.6 50.5 49.8 Measurements share this common tolerance unless otherwise stated. FRONT VIEW Housing Housing Housing Housing Housing H21, VIEW Housing Housing J11, Housing H21, Mechanical Data 660-3-6 250-6 SCHAFFNER 250-12 682-10 9675-16 250-20 9676-16 350-30 -8-12-20 Tol.* 27(J1) 8.5(J2)17(J3) 99.5 84.5 (J3) 84.5 98.5 99.5 84.5 29.5 660-10-16, 670-1.8-3-6, 680-2.5, 682-4, 9675-3-6 610-30, 612-30, 660-20, 670-10, 682-6.5 Measurements share this common tolerance unless otherwise stated. FRONT VIEW Housing K11, Housing Housing Housing VIEW Housing K11, Housing Housing Housing Mechanical Data Housing SCHAFFNER 402-A-02 401-0.8 401-1.5 402-A-07 402-A-16-38 Tol.* 0.05 22.5 6.25 37.5 16.5 19.5 17.5 43.5 16.5 Measurements share this common tolerance unless otherwise stated. SIDE VIEW Housing Housing KA2, KA3, Housing Housing BOTTOM VIEW Housing Housing KA2, KA3, Housing Housing Filter connections These standard types input output connections available Schaffner's range filter families. Schaffner also produce filters with other popular output connectors, user-specific interfaces, custom order. Please call your local sales office discuss custom requirements. SCHAFFNER Cross reference list copper area number inch 25.4mm (approx) 0.33 0.54 0.83 1.34 2.15 3.44 Dimensions 13.7 10.5 Type Solder with hole capable accommodating several small wires Type suitable direct assembly onto through-hole printed-circuit boards Type Clamp terminal with screw P/N/E (see mechanical data tables wire length gauge details) 10.8 12.3 Type Industry-standard size fast-on terminal, 0.8mm Type Industry-standard size fast-on which also used solder lug, 0.8mm 10.8 12.3 Type Insulated wire, stripped ready soldering. Wire gauge varies according filter 16.2 21.5 11.7 Type screw Type screw Type 8-32 screw Type Fast-on, 0.5mm Type Clamp terminal with screw 20.5 24.5 10.9 Type Safety terminal block Type Safety terminal block Type Solder/fast-on, 0.5mm Type Fast-on, 0.8mm 18.5 13.5 SCHAFFNER Schaffner's worldwide sales, distribution production network HEADQUARTERS Schaffner Nordstrasse CH-4542 Luterbach Switzerland Tel: (032) 6816 Fax: (032) 6816 Schaffner GmbH Schoemperlenstrasse D-76185 Karlsruhe Germany Tel: (0721) Fax: (0721) 9110 Northern Germany D-59581 Warstein Tel: (02902) Fax: (02902) Schaffner Galileo Galilei, I-20092 Cinisello Balsamo (MI) Italy Tel: (02) Fax: (02) Schaffner 2-31-6 Kamiuma Setagaya-Ku Tokyo 154-0011 Japan Tel: (03) 3418 5822 Fax: (03) 3418 3013 Schaffner 1200 Depot Road 06-01 Singapore 109675 Tel: 3283 Fax: 3281 Schaffner Turebergstorg S-19147 Sollentuna Sweden Tel: (08) 5792 1121 Fax: (08) 929690 Schaffner Altrac CH-8953 Dietikon Switzerland Tel: (01) 6111 Fax: (01) 6161 Schaffner Ashville Molly Millar's Lane Wokingham Berks RG41 Tel: (0118) 9770070 Fax: (0118) 9792969 Schaffner Fadem Road Springfield, 07081 Toll free: 5566 Tel: (973) 7778 Fax: (973) 1151 West Coast Irvine, 92718 Tel: (949) 9400 Fax: (949) 9510 DISTRIBUTORS Austria Eurodis Electronics GmbH Tel: Belgium Belgium Tel: 0747 Czech Republic Energo Praga Ltd. Tel: 6111 2665 Denmark Avnet Nortec Tel: Finland Electro Ferrum Tel: Germany Spoerle Electronic Tel: 6103 3048 Greece Micrelec Advanced Technologies Ltd. Tel: 5043 Netherlands Benelux Tel: Norway Avnet Nortec Tel: Poland Astat Tel: 8488 Spain Selco S.A. Tel: 1011 Sweden Avnet Nortec Tel: 1400 Turkey Artest Elektronik Tel: 1757 Australia Westek Industrial Products Ltd. Tel: 9369 8802 Brasil Teknikao Ltda Tel: 3901 3741 Hong Kong Denetron International Ltd. Tel: 9132 India Vishal Agencies Tel: 2079 Israel Components Ltd. Tel: 0707 Japan Nemic Lambda K.K. Tel: 3447 4411 Engineering Ltd. Tel: 3493 6613 Unidux Tel: 2232 4500 Korea Power Tel: 5852 Zealand Technologies Ltd. Tel: 7016 Republic South Africa Arrow Altech Ltd. Tel: 9600 Taiwan Bandtek International Ltd. Tel: 2657 2615 EUROLOGISTICS CENTER Schaffner avenue Suisse F-68311 Illzach France Tel: (03) Fax: (03) FACTORIES Schaffner Nordstrasse CH-4542 Luterbach Switzerland Tel: (032) 6816 Fax: (032) 6816 Schaffner National Technological Park Castletroy Limerick Ireland Tel: (061) 332233 Fax: (061) 332584 Schaffner Tambol Klang Amphur Muang Lamphun 51000 Thailand Tel: (053) Fax: (053) SALES SUBSIDIARIES Schaffner Beijing Liaison Office Room 911, Bright China Chang Building Jianguomennei Dajie Beijing 100005 China Tel: (10) 6510 1761 Fax: (10) 6510 1763 Schaffner Michel F-95103 Argenteuil France Tel: (01) Fax: (01) Rhone Alpes F-38560 Champ Drac Tel: (04) Fax: (04) Rennes F-35510 Tel: (02) Fax: (02) SCHAFFNER 690-339H Benteli Hallwag October 1998 Schaffner Elektronik CH-4542 Luterbach, Switzerland Tel: [+41] (32) 6816 Fax: [+41] (32) 6816 www.schaffner.com 1995 Schaffner Elektronik. Specifications subject change without notice. trademarks recognised. Certified 9001 supplier Schaffner ISO-registered company. products designed manufactured under strict quality requirements 9001 standard. This document been carefully checked. However, Schaffner does assume liability errors inaccuracies. Other recent searchesMAX5972A - MAX5972A MAX5972A Datasheet LC72191 - LC72191 LC72191 Datasheet IC61LV6416 - IC61LV6416 IC61LV6416 Datasheet CY7C1316BV18 - CY7C1316BV18 CY7C1316BV18 Datasheet CY7C1916BV18 - CY7C1916BV18 CY7C1916BV18 Datasheet CY7C1318BV18 - CY7C1318BV18 CY7C1318BV18 Datasheet CY7C1320BV18 - CY7C1320BV18 CY7C1320BV18 Datasheet CP0402P - CP0402P CP0402P Datasheet AN8602 - AN8602 AN8602 Datasheet ABH10 - ABH10 ABH10 Datasheet 2SC4005 - 2SC4005 2SC4005 Datasheet 1772269 - 1772269 1772269 Datasheet
Privacy Policy | Disclaimer |