| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
zzz-105Cnd-xxx GENERAL PURPOSE DECODER; RADIO, INFRA-RED, PAGER R
Top Searches for this datasheetREMOTE RECEIVER DECODER RADIO INFRA-RED PAGER zzz-105Cnd-xxx GENERAL PURPOSE DECODER; RADIO, INFRA-RED, PAGER RELAY CHANNELS EXPANDABLE RADIO FREQS; IP65 RATED ENCLOSURE EASY INSTALLATION SCREW TERMINALS 230VAC 12-30VDC SUPPLY CMOS/TTL CHANNEL O/P's INDICATION EACH RELAY OUTPUT. MOMENTARY LATCHING OUTPUTS TIMED OUTPUT ADJUSTABLE secs RELAY CONTACTS 2.5A 230VAC REQUIRES RADIO LICENCE DESCRIPTION general-purpose decoder which operate radio, infra-red pager system. unit supplied tough enclosure with IP65 rating, complete ready operate. pager system (using Globemaster Module G100UK), unit stand-alone pager controller. radio infrared decoder, system supplied with several modules enable user choose optimum frequency modulation range. decoder self-learning feature, which enables learn signature code individual Solutions KEELOQ encoders. Connections power supply relay outputs provided through screw terminals (these only connections required). output relays rated 2.5A 240VAC operating either momentary latched operation. additional "Low battery" relay also provided indicate that encoder battery voltage low. Output variable time feature, which adjusted give timed output (upto minutes). further momentary digital channels also provided expansion using `115' Expander (See datasheet DS000115). Performance Table Modulation Frequency (MHz) Infra-Red Globemaster Transmit Output Power (mW) DS000100 Range 1000 3,000 *NOTE: Range figure typical indication only. Range depends many factors, e.g. antennae, interference, environmental conditions. DS000105 ©1999 Reg. 4001, ENGLAND Page REMOTE RECEIVER DECODER RADIO INFRA-RED PAGER DECODER CONNECTIONS zzz-105Cnd-xxx INFRA-RED 240VAC Mains RECEIVER PAGER MAINS TRANSFORMER +12V DIGITAL decoder requires either single 12-30 supply 240VAC mains. BOTH! DIGITAL OUTPUT N/OCOMMN/C N/OCOMM N/OCOMMN/C O/P2 N/OCOMMN/C O/P3 N/OCOMMN/C O/P4 WARNING! unit designed fixed installation, which connected mains supply. Before removing cover ensure that mains input supply removed. operation product that involves removal front cover should only carried competent person qualified electrician. CONFIGURING OUTPUTS (Jumper Links These links configure operation digital outputs according table below. NOTE: link status read only power after changing links please remember remove reapply power. Open Open Connected Connected Latch: Open Connected Open Connected Latch Timed Latch Timed Latch Momentary Latch Momentary Latch Momentary Momentary Latch Latch Momentary Momentary Latch relay operates until next valid transmission received Momentary: relay operates momentarily (approx. 600mSecs) long encoder switch held DS000105 ©1999 Reg. 4001, ENGLAND Page REMOTE RECEIVER DECODER RADIO INFRA-RED PAGER RELAY OUTPUTS zzz-105Cnd-xxx system supplied with relay(s) type OMRON GL5114P equivalent. alternative which fitted BT47W/6. Notes: Only relay output channel must fitted. user must ensure that load connected does overload relay! battery relay mains rated Output Channel Relay Type OMRON G5L114P BT47W/6 Battery RLY9 TIMED OUTPUT Output variable timed output controlled VR1. This adjusted from delay maximum minutes seconds. Turning clockwise increases output delay. BATTERY RELAY battery feature informs user that encoder used voltage battery. BATT channel operates decoder received transmitted signal with voltage signal present. This will continue operate until transmitted signal without voltage signal been received. NOTE: BATT relay type BT47W/6. Expanding system Relay outputs relay expansion unit available connect directly `105' Series Remote Decoder single connector screw terminal) provides momentary relay output channels, mapped directly from `105 digital outputs. additional relay (channel also provided, this operates relay channels operated (Wired configuration). Operation each relay indicated system supplied IP65 rated enclosure requires either 240Vac 12-30Vdc supply. unit easy install; connections screw terminals. further information please Datasheet DS000115. LEARNING ENCODER Press programming switch decoder once (SW1) learn will illuminate Press switches encoder once, learn decoder will extinguish Press switches encoder again, learn will flash When learn stopped flashing this encoder will operate system ERASING EXISTING ENCODER completely erase encoders, press decoder seconds. learn will turn after seconds indicate encoder(s) have been erased NOTE: erase individual encoders DS000105 ©1999 Reg. 4001, ENGLAND Page REMOTE RECEIVER DECODER RADIO INFRA-RED PAGER zzz-105Cnd-xxx APPLICATION NOTE: IMPLEMENTING SWITCH REMOTE CONTROL SYSTEM possible implement channel remote control system using R.F. Solutions RF103 RF107 encoders digital outputs connector RF105 decoder. Encoder Connections: following diagram shows connect switches connector RF103 RF107 encoders. Note that diodes D2-D29 must fitted. (PINS 16-20) SW15 SW14 SW13 SW12 SW11 SW10 (PINS 16-20) Switch Connections RF103 Decoder Connections: digital outputs located connector These momentary CMOS/TTL compatible outputs. decoder output channels directly linked inputs encoder decoder output channels also operated from four switches encoder RF102 RF103 using binary coded decimal inputs shown below. Encoder Digital Inputs (J2) Decoder Digital Output (J5) Output channel 3,2,1 4,2,1 4,3,1 4,3,2 4,3,2,1 DS000105 ©1999 Reg. 4001, ENGLAND Page REMOTE RECEIVER DECODER RADIO INFRA-RED PAGER zzz-105Cnd-xxx following diagram shows example connect digital outputs connector drive external relays. +12V +12V G5L114P Dig. Dig. Dig. Dig. Dig. Dig. Dig. Dig. Output Output Output Output Output Output Output Output G5L114P G5L114P G5L114P G5L114P G5L114P ULN2803 G5L114P G5L114P Relay Buffering Circuit RF105 Digital Outputs DS000105 ©1999 Reg. 4001, ENGLAND Page REMOTE RECEIVER DECODER RADIO INFRA-RED PAGER TECHNICAL SPECIFICATIONS Storage Temperature; +70o Celsius. Operating Temperature; +55o Celsius. zzz-105Cnd-xxx Dimensions: Enclosure PCB: 106mm ELECTRICAL CHARACTERISTICS Supply Voltage Supply Current Quiescent Time from Encoder Switch depressed relay output Relays operating Relay Rating (240Vac) RLY1-4 Relay Rating RLY5-9 Relay Rating RLY5-9 11.0 TYPICAL 16.0 30.0 DIMENSION mSecs @12Vdc @0.5A Part Numbering decoder part number made follows zzz-105Cnd-xxx Character Meaning Modulation Possible values G100 173, 433,458,868 Notes AM-Superegenerative Superhetrodyne Infra-Red Globemaster enclosure 12-30Vdc only 240Vac 12-30Vdc Frequency Examples, Product Identifier Supplied Enclosure Relays Power Supply Frequency operation AM-1054D-433 FM-1051A-458 SuperRegen decoder with relays, power supply, operating 433MHz. Superhetrodyne decoder with relay, mains power supply, operating 458MHz. more information general enquiries, please contact Solutions Ltd., Unit Cliffe Industrial Estate, South Street, Lewes, Sussex, 6JL. England (0)1273 Email sales@rfsolutions.co.uk (0)1273 http://www.rfsolutions.co.uk Solutions member Power Radio Association Trademarks acknowledged remain property respected owners Information contained this document believed accurate, however representation warranty given R.F. Solutions Ltd. assumes liability with respect accuracy such information. R.F.Solutions critical components life support systems authorised except with express written approval from R.F.Solutions Ltd. DS000105 ©1999 Reg. 4001, ENGLAND Page Other recent searchesV6108 - V6108 V6108 Datasheet TEA2031A - TEA2031A TEA2031A Datasheet MJD5731 - MJD5731 MJD5731 Datasheet MAX3488 - MAX3488 MAX3488 Datasheet MAX3486 - MAX3486 MAX3486 Datasheet FR10-005G - FR10-005G FR10-005G Datasheet FR10-10G - FR10-10G FR10-10G Datasheet DS25BR100 - DS25BR100 DS25BR100 Datasheet DS25BR100EVK - DS25BR100EVK DS25BR100EVK Datasheet BU2520AX - BU2520AX BU2520AX Datasheet
Privacy Policy | Disclaimer |