| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
2192-09458-000-000 PCRELAY8/IN8 Packing List This produ
Top Searches for this datasheetJ553 PCRELAY8/IN8 2192-09458-000-000 PCRELAY8/IN8 Packing List This product shipped follows: Board User Manual Utility Disk PCbus Library Datasheet above appear missing, please telephone Arcom 01223 200. 8-bit add-on Board Utility Disk This product shipped with Utility Disk which contains: PCbus Library Manual Source Code PCbus boards test program called EXAMP-01.EXE Handling This board contains CMOS devices which could damaged event static electricity being discharged through them. times please observe anti-static precautions when handling board always unpack install board anti-static working area. Please ensure that should board need returned Arcom, adequately packed battery fitted, that isolated. Product Information Full information about other Arcom products available Fax-on-Demand System, (Telephone Numbers listed below), contacting WebSite www.arcom.co.uk. Customer Support Tel: (0)1223 Fax: (0)1223 E-mail: support@arcom.co.uk United Kingdom Arcom Control Systems Clifton Road Cambridge 4WH, Tel: 01223 Fax: 01223 FoD: 01223 Useful Contact Information Sales Tel: (0)1223 Fax: (0)1223 E-mail: sales@arcom.co.uk France Arcom Control Systems Centre daffaires SCALDY Colbert 7885 SAINT QUENTIN Cedex, FRANCE Tel: Fax: FoD: E-mail icpsales@arcomcontrols.com United States Arcom Control Systems 13510 South Street Kansas City 64145 Tel: 7025 Fax: 0343 FoD: 1097 Germany Kostenlose Infoline: Tel: 0130 Fax: 0130 FoD: 0130 Netherlands Gratis 0800 Nummer: Tel: 0800 0221136 Fax: 0800 0221148 Italy Numero Verde: Tel: 1677 80841 Fax: 1677 90841 FoD: 1678 73600 Belgium Groen Nummer: Tel: 0800 3192 Fax: 0800 3191 Whilst Arcoms sales team always available assist making your decision, final choice boards systems solely wholly responsibility buyer. Arcoms entire liability respect boards systems Arcoms standard terms conditions sale. intend write your level software, start with source code disk which supplied. This example code only illustrate Arcoms products. been commercially tested. warranty made respect this code Arcom shall incur liability whatsoever howsoever arising from made code. 1997 Arcom Control Systems Ltd. Arcom Control Systems subsidiary Fairey Group Plc. trademarks recognised. Arcom Control Systems operate company-wide quality management system which been certified British Standards Institution (BSI) compliant with ISO9001:1994 Page 2192-09458-000-000 J553 PCRELAY8/IN8 Introduction PCRELAY8/IN8 8-bit add-on board providing changeover relays. power switching rating (resistive load). This allows supplies upto switching currents 1.0A. There also opto-isolated inputs providing input output isolation 1500v. compliant design changeover relays with power switching rating (resistive load) Switching voltage switching currents 1.0A opto-isolated inputs complete with current limiting resistors input Opto-input switching voltage: Output status readback register Occupies Bytes Address Space Relay drivers disabled power-up reset Both normally closed normally open relay terminals available connector Link selectable debounce option inputs Link selectable, even boundary base address Board access Operating temperature range, +5°C 55°C Power consumption ±0.25V 250mA typical 40mA relay operating Relay life rating 500,000 operations minimum full load) Features Getting Started Switch Install board supplied configuration Switch EXAMP-01.EXE (supplied utility disk) access/user should flash. check default link configuration (Page Operation Each relay switched writing relay output register. power-up reset output latches that drive relay drivers disabled. enable them necessary write base address system initialisation, recommended that output register written with required relay states before relay relay enable set. status opto inputs read form address base When input channel switched value read host will Page J553 PCRELAY8/IN8 2192-09458-000-000 Address Offset Register name Relay output Relay status Relay enable Opto-inputs Read/Write Comments Write relays Readback from relay drivers Enable relay driver latches Read Opto-inputs Relay outputs function relay relay contacts closed relay contacts closed relay position relay position Relay status Relay enable relays position) relays controlled relay output register Opto inputs input input Links Address Selection base address this board using LK1; inserting jumper selects Debounce Option Link Position Data Page 2192-09458-000-000 J553 PCRELAY8/IN8 Default Link Position [Default address 180h] User Configuration Record Output Connector assignments DType Ribbon Cable Function connected Relay connected Relay common Relay connected Relay connected Relay common Relay connected Relay connected Relay common Relay connected Relay connected Relay common Relay common input (low bits) input input input input Ribbon Cable Function Relay common Relay connected Relay connected Relay common Relay connected Relay connected Relay common Relay connected Relay Connected Relay common Relay connected Relay connected input input input input common input (high bits) DType Page J553 PCRELAY8/IN8 2192-09458-000-000 Installation Compliance maintain compliance with requirements directive (89/336/EEC), this product must correctly installed. which board housed must compliant declared manufacturer. type external cable chosen according notes below: Remove cover observing additional instructions manufacturer. Locate board spare slot press gently firmly into place. Ensure that metal bracket attached board fully seated. bracket clamping screw firmly tighten this bracket. Note: Good contact bracket chassis essential. Replace cover observing additional instructions manufacturer. Cable length Metre less Cable Longer cable noisy environment Cable Ribbon cable satisfactory Commercial screened cable gives protection required fully screened cable with metal backshells e.g. Arcom CAB50CE following standards have been applied this product: EN50081-1: 1992 Generic Emissions Standard, Residential, Commercial, Light Industry EN50082-1: 1992 Generic Immunity Standard, Residential, Commercial, Light Industry BSEN55022: 1995 Emissions, Class Limits Methods Page 2192-09458-000-000 J553 PCRELAY8/IN8 Page J553 PCRELAY8/IN8 2192-09458-000-000 Page 2192-09458-000-000 J553 PCRELAY8/IN8 Revision History Manual Issue Issue Issue Issue Issue Issue Issue 960927 961129 970124 970207 970326 980127 980707 Comments First full release Manual. [ECO2359,2370] [ECO2458] [ECO2465] [ECO2493] [ECO2684] [ECO2748] Page Other recent searchesVAOL-5MCE2 - VAOL-5MCE2 VAOL-5MCE2 Datasheet K3040 - K3040 K3040 Datasheet K3041 - K3041 K3041 Datasheet GO2922-3131CM - GO2922-3131CM GO2922-3131CM Datasheet CR14250 - CR14250 CR14250 Datasheet CFAF320240F-T - CFAF320240F-T CFAF320240F-T Datasheet BD646 - BD646 BD646 Datasheet BD648 - BD648 BD648 Datasheet BD650 - BD650 BD650 Datasheet BD652 - BD652 BD652 Datasheet BD645 - BD645 BD645 Datasheet BD647 - BD647 BD647 Datasheet BD649 - BD649 BD649 Datasheet BD651 - BD651 BD651 Datasheet 28R2000-010 - 28R2000-010 28R2000-010 Datasheet
Privacy Policy | Disclaimer |