| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
models feature same compact dimensions provide uniform mounting pitch.
Top Searches for this datasheetWide Range Models with 40-A Output Currents 480-VAC/200-VDC Output Voltages models feature same compact dimensions provide uniform mounting pitch. Built-in varistor effectively absorb external surges. Operation indicator (red LED) enables monitoring operation. Protective cover greater safety. Standard models approved UL/CSA -UTU models G3NA Ordering Information Isolation Phototriac Photocou Photocoupler Phototriac Photocoupler ocou Zero cross function Indicator Rated output load (Applicable output load) VAC* VAC) Rated input voltage VAC* VAC) VAC* (180 VAC) -Phototriac Photocoupler ocou VDC* VDC) VAC* VAC) VAC* (180 VAC) Phototriac Photocoupler ocou VAC* VAC) VAC* (180 VAC) VAC* (180 VAC) *Loss time increases under VAC. (Refer page 148.) Note: When ordering model, "-UTU" model number shown below: Example: G3NA-210B-UTU G3NA-450B G3NA-440B G3NA-240B G3NA-420B G3NA-220B G3NA-D210B G3NA-410B G3NA-210B Model G3NA-205B G3NA Accessories (Order Separately) Heat Sink following heat sinks thin DIN-track mounted (except Y92B-P250). Dimensions details. Model Y92B-N50 Y92B-N100 Y92B-N150 Y92B-P250 Applicable G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B, G3NE-205T(L), G3NE-210T(L) G3NA-220B, G3NA-420B, G3NE-220T(L) G3NA-240B, G3NA-440B G3NA-450B Low-cost Models Model Y92B-A100 Y92B-A150N Y92B-A250 Applicable G3NA G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-220B, G3NA-410B, G3NA-420B G3NA-240B, G3NA-440B G3NA-440B Mounting Bracket Used mount G3NA with mounting dimension Model R99-11 Applicable G3NA-240B, G3NA-440B Dimensions details. (Refer page 148.) Specifications Ratings Input (Ambient Temperature: 25°C) Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage G3NA-2jjB G3NA-4jjB G3NA-D210B Note: max.* k±20% k±20% max.* k±20% max. max.** max.** max. max. Must release voltage min. min.** min.** min. min. input impedance measured maximum value rated supply voltage (for example, with model rated VAC, input impedance measured VAC). *With constant current input circuit system. impedance G3NA-jjjB-UTU max. **Refer Engineering Data further details. Output Model Rated load voltage G3NA-205B G3NA-210B G3NA-410B G3NA-220B G3NA-420B G3NA-240B G3NA-440B G3NA-450B G3NA-D210B Load voltage range Applicable load Load current With heat sink* Without heat sink cycle) cycle) cycle) cycle) Inrush current *When OMRON's heat sink (refer accessories) heat sink specified size used. G3NA Characteristics Item Operate time Release time Output voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Approved standards Ambient humidity Weight G3NA-205B, -210B, -220B G3NA-240B G3NA-410B, -420B, -440B, -450B G3NA G3NA-D210B max. input) max. input) max. input) max. input) max. max. VDC) load power source cycle max. input) load power source cycle max. input) load power source cycle max. input) load power source cycle max. input) (RMS) max. max. VAC) max. VAC) min. VDC) 2,500 VAC, 50/60 Malfunction: 1.5-mm double amplitude Malfunction: 1,000 m/s2 Operating: -30°C 80°C (with icing condensation) Storage: -30°C 100°C (with icing condensation) UL508 File No.E64562/CSA C22.2 (No.0, No.14) File No.LR35535 R9151660 (EN60950) Operating: Approx. Approx. Approx. (RMS) max. max. VAC) max. VAC) Approx. G3NA G3NA Engineering Data Load Current Ambient Temperature Characteristics G3NA-205B G3NA-210B/410B G3NA-220B/420B Load current Load current With standard heat sink (Y92B-A100 Y92BN50) aluminum plate measuring 13.2 Without heat sink With standard heat sink (Y92B-A100 Y92B-N50) aluminum plate measuring 13.2 With iron plate measuring Without heat sink Load current With standard heat sink (Y92B-A100 Y92B-N100) aluminum plate measuring 13.2 With iron plate measuring Without heat sink Ambient temperature (°C) G3NA-240B Ambient temperature (°C) G3NA-440B With Y92BA250 heat sink with radiation efficiency 1°C/W. With standard heat sink (Y92B-A150N Y92B-N150) Ambient temperature (°C) G3NA-D210B Load current Load current Load current With standard heat sink (Y92B-A150N Y92B-N150) With standard heat sink (Y92B-A100 Y92B-N50) aluminum plate measuring 13.2 With iron plate measuring Without heat sink With iron plate measuring Without heat sink With iron plate measuring Without heat sink Ambient temperature (°C) G3NA-450B Ambient temperature (°C) Ambient temperature (°C) With standard heat sink (Y92B-P250) Load current Without heat sink Ambient temperature (°C) G3NA Inrush Current Resistivity Non-repetitive (Keep inrush current half rated value occurs repetitively.) G3NA-205B G3NA-210B/410B G3NA-220B/420B G3NA Inrush current Peak) Inrush current Peak) Energizing time (ms) Energizing time (ms) Inrush current Peak) Energizing time (ms) Temperature Characteristics (with Must Operate Voltage Must Release Voltage) G3NA-240B/440B/450B G3NA-D210B G3NA-2jjB Input Inrush current Peak) Inrush current Peak) Energizing time (ms) Energizing time (ms) Variation rate Ambient temperature (°C) Heat Sink Size Load Current G3NA-220B Ambient temperature 80°C Ambient temperature 40°C Heat sink size (cm2 Note: heat sink size refers combined area sides heat sink that radiate heat. example, when current allowed flow through 40°C, graph shows that heat sink size about cm2. Therefore, heat sink square, side heat sink must (152 450) longer. Aluminum plate thick Load current G3NA G3NA Dimensions Note: units millimeters unless otherwise indicated. case surface mounting, derating load current required. orientation indicated external dimensions correct mounting orientation. When opening mounting holes, refer mounting hole dimensions. G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B Four, dia. screws Mounting Holes Terminal Arrangement/ Internal Connections (Top View) Load Load power supply Input Two, 4.3-dia. holes max. 47.5 Load 47.6±0.2 Operating indicator 13.8 max. max. max. G3NA-240B, G3NA-440B, G3NA-450B dia. Two, screws Mounting Holes Terminal Arrangement/ Internal Connections (Top View) Load Load power supply Input Two, 4.3-dia. holes min.47.5 Load 47.6±0.2 Operating indicator max. Two, M4x8 13.8 max. max. G3NA-D210B Four, dia. screws Mounting Holes Terminal Arrangement/ Internal Connections (Top View) Load Load power supply Input max. 47.5 Two, 4.3-dia. holes Load 47.6±0.2 max. Operating indicator 13.8 max. max. Heat Sink Y92B-N50 Mounting Holes dia. Two, holes Two, holes Two, 3.2-dia. holes max. max. 90±0.4 max. 35±0.2 30.5±0.3 Two, 4.4-dia. holes 47.6 max. 90±0.3 max. Weight: approx. G3NA Y92B-N100 dia. Two, holes Two, holes G3NA Mounting Holes Two, 3.2-dia. holes 35±0.2 max. 30.5±0.3 max. Two, 4.4-dia. holes 90±0.4 47.6 max. 90±0.3 max. max. Weight: approx. Y92B-N150 dia. 47.6 Three, holes Two, 3.2-dia. holes Mounting Holes 35±0.2 max. max. 90±0.4 Two, 4.4-dia. holes 56±0.3 max. 90±0.3 max. max. Weight: approx. Y92B-A100 Y92B-A150N Three, holes Y92B-A250 Three, holes ±0.1 ±0.1 ±0.1 Two, holes 100.5 max. 80.5 max. R2.2 47.6 R2.2 47.6 47.6 50±0.1 max. 50±0.1 56±0.5 max. 50±0.1 56±0.5 max. 45.5 max. Mounting Holes Y92B-A100 Y92B-A150 Y92B-A250 Four, Four, 4.3-dia. holes Mounting Holes Four, dia. 190.5 max. 90±0.1 50±0.1 Four, R2.5 130.5 max. max. G3NA R99-11 12.5 G3NA Mounting Bracket R99-11 that G3NA-240B mounted with same pitch that G3N-240B. Precautions Refer pages general precautions. Load Connection load, power supply rated maximum operating frequency G3NA built-in varistor overvoltage protection. When attaching heat sink G3NA, apply Silicone Grease equivalent heat conductive grease heat sink. (Toshiba Silicon, Shinetsu Silicon, etc.) Tighten mounting screws heat sink with torque 0.78 0.98 EN55011 Measurement Mains Terminal Disturbance Voltage G3NA-UTU conforms EN55011 standards when capacitor connected load power supply shown following circuit diagram. Load Input G3NA-UTU Output Zero Cross Function with zero cross function operates when load voltage reaches zero point vicinity. This reduces clicking noises when load input, minimizes influence inductive load, such lamp, heater, motor, power supply because inrush current load reduced. This also minimize scale inrush current protection circuit. Output (load voltage) Input applied voltage, such VAC, load current fully supplied. When Unit switched voltage required power Unit deprives output signal necessary voltage level thus creates loss time. lower load voltage greater loss time This condition, however, will create serious problems. Recommended Capacitor: Nissei Denki's MKT-series output terminal side G3NA-D210B connected builtin diode protecting from damage that result from reverse connection. SSR, however, cannot withstand minute more wires connected reverse order. Therefore, utmost attention make polarity mistakes load side. Loss time load, diode should connected parallel load absorb counter electromotive force load. Load Input Load power supply DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. Cat. K067-E1-1C Other recent searchesTS358 - TS358 TS358 Datasheet SUP90N08-8m2P - SUP90N08-8m2P SUP90N08-8m2P Datasheet STQ1NC60R - STQ1NC60R STQ1NC60R Datasheet LT1841-81 - LT1841-81 LT1841-81 Datasheet LL-204ID2L-I1 - LL-204ID2L-I1 LL-204ID2L-I1 Datasheet LC895126 - LC895126 LC895126 Datasheet 2SB859 - 2SB859 2SB859 Datasheet
Privacy Policy | Disclaimer |