| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Approved EN61000, IEC-1000, UL1950, 22.2 950-95 Operating ambient temp
Top Searches for this datasheetAFE2000 SERIES Approved EN61000, IEC-1000, UL1950, 22.2 950-95 Operating ambient temperature +50°C Complies with ETS300 132-1 EN61000-3-2 Hot-swap capability 11.5 6.75 inch size redundancy capability Extensive features available Compatible with standard shelves configuring rack-mounted power systems AFE2000 power module rack mountable single phase power supply, designed cost-competitive front-end power supply distributed power systems. particularly suitable data processing, datacom telecom applications. outputs floating user ground plus, minus neither depending application. AFE2000 power modules designed hot-swap operation mounted into AFS4000/6000 power shelves redundant-mode operation. YEAR WARRANTY SPECIFICATION OUTPUT SPECIFICATIONS Output voltage Output power Regulation Turn-on specifications typical nominal input, full load 25°C unless otherwise stated CHARACTERISTICS ±1.0% ±1.0% 2000W ±3.0% Conducted emissions Radiated emissions Immunity conducted Immunity radiated Immunity Line harmonics FCC-CFR, part subpart Class CISPR Class FCC-CFR, part subpart (Note CISPR (Note IEC1000-6 Level IEC1000-3 Level IEC1000-2 Level EN61000-3-2 Compliant Main: 48/54.5/56.2VDC Auxiliary: 12VDC Main Auxiliary Line, load, ageing Output rise time 400ms Turn-on applied) max. Turn-on (inhibit removed) 1.5s max. 480mV pk-pk 3kHz 35dBrnC 60VDC max. Delivers full power Latch-off Automatic recovery Latch-off ±10% GENERAL SPECIFICATIONS Hold-up time (See Note Efficiency Isolation voltage Input/output Input/chassis Output/chassis 170VAC 150VAC 500ms 20ms 3000VAC 1500VAC 100VAC 200kHz EN60950, IEC950, UL1950 C22.2 Electrolytic zinc coated CRS, ASA591, light beige paint 5.0kg (11Ibs) MIL-HDBK-217E Demonstrated 150,000 hours 300,000 hours Ripple noise (<50MHz) Transmission noise Overvoltage protection Undervoltage protection >44.5VDC <42VDC Short circuit protection Current sharing Remote sense INPUT SPECIFICATIONS Input voltage range Input frequency range Input surge current Safety ground leakage current Input current Power factor 200/240VAC nom. 50/60Hz nom. 25°C cold start 254VAC 60Hz 220VAC, 2000W <30s >30s Switching frequency Approvals standards Case material Weight Active current share (50% 100% loading) 1.0V max. distribution line loss MTBF 264VAC 47Hz 63Hz 1.5mA max. 0.5mA typ. 10.5A 0.99 min. ENVIRONMENTAL SPECIFICATIONS Thermal performance Cooling Relative humidity Altitude Vibration Shock Operating Operating 500Hz Operating ambient Non-operating +50°C -40°C +100°C Forced 13,000 feet max. 0.75G peak 15G, Sine, 11ms PAGE DISTRIBUTED POWER FRONT AC/DC POWER SUPPLIES 2000W AC/DC 2000 Watt AC/DC front-end distributed power architectures OUTPUT VOLTAGE 48VDC 54.5VDC 56.2VDC OUTPUT CURRENT RIPPLE 41.7A 36.7A 35.6A 480mV 545mV 562mV TOTAL REGULATION ±3.0% ±3.0% ±3.0% REMOTE ENABLE/INHIBIT Inhibit Inhibit Inhibit PARALLEL INTERFACES AFE2000-26S48NA AFE2000-26S54NA AFE2000-26S56NA MODEL NUMBER Parallel interface specifications. signals referenced ISO_GND unless otherwise indicated. Isolated signal ground (ISO_GND) connected voltage range from +Vout+5VDC -Vout5VDC. Overtemperature (OTW) Output bi-level signal. Bi-level signals open-collector (drain) with sink capability maximum voltage stand-off 60VDC. Logic Signal precedes shutdown 5ms. Logic Normal operation. Remote Inhibit (INHIBIT) Input bi-level signals. Bi-level input signals shall greater than 5VDC. Logic Normal operation. Logic Output inhibit. Voltage margin down (DOWN) Input bi-level signals. Bi-level input signals shall greater than 5VDC. Logic Nominal output voltage. Logic 44.5 45.5VDC output. Power good signal (PWR_GOOD) Output bi-level signal. Bi-level signals open-collector (drain) with sink capability maximum voltage stand-off 60VDC. Logic Output undervoltage. Logic Output voltage normal. Fault fail signal (F/F Differential relay contact, isolated from outputs returns within power module. Relay closed Power supply failure Relay open Normal operation. Power fail warning signal (PFW) Output bi-level signal. Bi-level signals open-collector (drain) with sink capability maximum voltage stand-off 60VDC. Logic Signal precedes loss output power 5ms. Logic Normal operation. Module Missing (MM) Provision detection unseated removed module. pins common internal power supply. Internal pull-up resistor +5VDC logic bias, referenced RS-. Auxiliary Output (AUX 12VDC auxiliary output. Isolated from both main output isolated signal ground. utilized external housekeeping supply connected either main output isolated signal ground. Current Monitor (IMON) Current source which mirrors magnitude output current. Signal return referenced RS-. Current Limit (CL) Output bi-level signal. Bi-level output signal open-collector (drain) with sink capability maximum voltage stand-off 60VDC. Logic Output current mode control current limiting. Logic Normal operation. Remote Enable (ENABLE) Input bi-level signal. Bi-level input signal shall greater than 5VDC. Logic Output inhibited. Logic Normal operation. Reset (RESET) Input bi-level signal. Bi-level input signal shall greater than 5VDC. Logic Resets fault indicators without unit shut-down. Logic Normal operation. Good Output bi-level signal. Bi-level output signal open-collector (drain) with sink capability maximum voltage stand-off 60VDC. Logic input below normal operating range. Logic input within steady-state operating range (170 264VAC). Voltage monitoring (VMARG) Input analog signal referenced RS-. Adjusts output 4VDC higher than nominal point. Features Live insertion removal OR-ing diodes provided output. Voltage monitoring jacks Located front panel. LED's (located front panel) Power Good Power Fail Good Green Green Protection Thermal protection automatic shut-off failure internal overtemperature. Output Overload Short Circuit automatic shut-down after seconds. Current regulated output down less than 1VDC. Output Overvoltage automatic shut-down both main (60VDC max.) auxiliary (15.6VDC max.) outputs. Output Undervoltage automatic shut-down below 42VDC. Current Share Active current sharing AFE2000 power modules. Short Short located output connector initiates shut-down power supply output when power supply removed from host power shelf. International Safety Standard Approvals EN60950/IEC950 File E9972397 UL1950 File E135734 Please consult website following items: Application Note http://www.artesyn.com PAGE 2000W AC/DC DISTRIBUTED POWER FRONT AC/DC POWER SUPPLIES 2000 Watt AC/DC front-end distributed power architectures CONNECTIONS Notes signal warning issued msec prior shutdown. Chassis safety ground. Isolated signal ground. Output ground referenced RS-. Refer Application Note installation AFE2000 power modules into AFS4000 power shelf. FUNCTION Short AUX+ AUXRSNot Used Used FUNCTION DOWN VMARG RESET IMON Power Good FUNCTION RSMM F/FF/F+ INHIBIT/ENABLE FUNCTION +Vout +Vout CGND Refer Application Note description outputs signals available with AFE2000 power modules installed Artesyn standard frontend power shelf. Class power module, Class when installed AFS4000 shelf (subject cable/system configuration). SHORT SIGNAL FLOW NORMAL 6.44 (163.58) 0.074 (1.879) 6.75 (171.45) 1.30 (33.02) 11.46 (291.08) 0.25 (6.35) INPUT POWER DYNAMICS 42R08-1122 MATE POWER DYNAMICS 43R06-2114 5.725 (145.415) 0.050 (1.270) TAPERED GUIDE HOLE 0.800 (20.32) 4.23 (107.44) 4.83 (122.68) 0.0875 (2.2225) 2.063 (52.400) 0.625 (15.875) GOOD FAIL GOOD (J2) connector Elcon 279-0468-00100 equivalent. (J1) connector Power Dynamics 42R08-1122 equivalent. Data Sheet Artesyn Technologies® 2001 information specifications contained this data sheet believed correct time publication. However, Artesyn Technologies accepts responsibility consequences arising from printing errors inaccuracies. Specifications subject change without notice. rights under patent accompany sale such product(s) information contained herein. PAGE 0.475 (12.065) TAPERED GUIDE HOLE 0.462 (11.735) 0.375 (9.525) MAIN OUTPUT/SIGNALS ELCON 279-0468-00100 MATE ELCON 278-0468-00200 INSERTION/EJECTOR HANDLE WITH 6-32 CAPTIVE SCREW (J2) mating connector Elcon 278-0468-00200 equivalent. (J1) mating connector Power Dynamics 43R06-2114 equivalent. DS_AFE2000_20010403.PDF Other recent searchesZX95-2700+ - ZX95-2700+ ZX95-2700+ Datasheet SiR488DP - SiR488DP SiR488DP Datasheet MM74HCT04 - MM74HCT04 MM74HCT04 Datasheet DF5A5 - DF5A5 DF5A5 Datasheet BFS17P - BFS17P BFS17P Datasheet BDCN-17-25 - BDCN-17-25 BDCN-17-25 Datasheet AMMP-6120 - AMMP-6120 AMMP-6120 Datasheet 2SC4057 - 2SC4057 2SC4057 Datasheet
Privacy Policy | Disclaimer |