The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

CLICK FILE OVERVIEW Inductive Proximity Sensors Introduction


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



FIND
CLICK FILE
OVERVIEW Inductive Proximity Sensors
Introduction Operation
CLICK FILE
CYLINDRICAL Inductive Proximity Sensors
Introduction/Operation Selection Guide, styles.12 Selection Guide, styles Product Specifications.16
LIMIT STYLE Inductive Proximity Sensors
Introduction/Operation Selection Guide.71 Product Specifications.72
CLICK FILE
BLOCK STYLE Inductive Proximity Sensors
Introduction/Operation Selection Guide.82 Product Specifications.84
CLICK FILE
RING STYLE Inductive Proximity Sensors
Introduction/Operation Selection Guide.100 Product Specifications.102
CLICK FILE
ACCESSORIES Inductive Proximity Sensors
Introduction .113 Mounting Brackets .114 Cable Assemblies.116 Switching Units.122 Motion Detectors.128
OTHER INFORMATION
APPENDIX: Codes .132 NEMA requirements .133 Cross Reference .134 Glossary.135 Conversion Charts .137 INDEX .138 TERMS CONDITIONS .141 WARRANTY.143
CLICK FILE
specifications subject change without notice obligation
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Cylindrical Sensors
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
CYLINDRICAL INDUCTIVE PROXIMITY SENSORS Altech Cylindrical sensors available diameters ranging from (.16 in.) 30mm (1.18 in.) with sensing distances 40mm (1.57 in.). Most models feature nickel plated brass (BN) housing, stainless steel (SS) non-metallic versions available. Both flush mount non-flush mount sensors available. Flush mount versions often called shielded embeddable. Non-flush mount sensors also called non-shielded nonembeddable. Non-flush sensors have larger sensing distances than their flush mount counterparts. Inductive sensors meet IP67 (NEMA1, protection levels. Please refer pages 132-133 this catalog more information.
HOME
FIND
Sensing Distances Cylindrical Style Sensors Type Series Short Body Series Standard Series Extended Sensing Range High Speed Plastic Metal Housing Mini Housing Complementary Output Extended Temperature Range Weld Immune Analog Output Extended Range Plus 2-Wire Namur Voltage Flush* Non-Flush*
FLUSH MOUNT CYLINDRICAL SENSORS Flush Mounted, sometimes called embedded shielded sensors, have electromagnetic fields concentrated directly front sensing heads mounted directly into metal mounting brackets embedded directly into metal without causing false output. Figure also illustrates that Cylindrical Flush Mount sensors there should least diameter distance between adjacent sensors, non-target metal surfaces should less than times sensing distance directly across from sensing head. Also, directly opposite sensors mounted metal should greater than times sensing distance apart.
*All Sensing Distances Operating Voltages Cylindrical Style 250VAC 30VDC 250VAC 30VDC 60VDC
Operating Current- Cylindrical Style 200mA
Sensor Wiring Systems Cylindrical Style 2-Wire 2-Wire 3-Wire 4-Wire
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
NON-FLUSH CYLINDRICAL SENSORS Sometimes called non-embedded non-shielded, non-flush sensors have electromagnetic fields with wide sensing angle unshielded metal surrounding sensing head). Care must taken insure that non-target metal comes near proximity sensing head. Distances demonstrated Figure Adjacent sensors should separated least times diameter. Non-target metal should least times sensing distance directly across from sensing head. directly opposite sensors should least times sensing distance apart. OUTPUT CONNECTIONS AC,DC Normally Open (NO), Normally Closed (NC). Namur Special interface Circuits required. Analog Analog Output OUTPUT CABLES Cylindrical Sensors provided with meter fixed cables. meter PVC, meter cables optional specified selection last digits part number. chart below. Cable Length Material Part Last Digits
HOME
FIND
Fig.
CYLINDRICAL SENSOR INSTALLATION
Flush Mount Installation (Mild Steel)
Non-Flush Mount Installation (Mild Steel)
Opposing Installation
(Mild Steel)
Quick Disconnect models designed user-friendly simplify installations. Please product specification sensors with quick disconnect connectors matching cable assemblies pages accessory section.
QUICK DISCONNECT HOUSING MATERIALS CONNECTORS Pulostronic sensors available Nickel Plated Brass Trogamid wide selection Quick Teflon Plated Brass Disconnect styles circuits. While virtually sensor Nickel Plated Brass custom manufactured with Trogamid Quick Disconnect connector, Altech Teflon Plated Brass offers largest selection Stainless Steel standard Quick Disconnect models.
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
CYLINDRICAL SENSORS SELECTION GUIDE
Sensing Distance (in.) Series Size (mm)
Extended Sensing 10-30V 200mA improvement over Standard Metal Plastic 10-30V 400mA Extended Length Higher Current Output Mini Housing 10-30V 200mA 6.5mm diameter Includes Complementary Switching Output 10-30V 200mA Outputs High Speed 10-30V 200mA 4,000 Switching Frequency Extended Temperature 10-30V 200mA -40°C 100°C Dia. 6.5mm Dia.
0.8mm (.03 in.) 1.0mm (.04 1.5mm (.06 in.) 2.0mm (.08 in.) 2.5mm (.10 in.) 3.0mm (.12 in.) 4.0mm (.16 in.) 5.0mm (.20 in.) 6.0mm (.23 in.) 7.0mm (.28 in.) 8.0mm (.32 in.) 10.0mm (.40 iin.) 12.0mm (.47 in.)
Series 18-30V 120mA Short Body Economically priced Series 10-60V 400mA LED's models Standard Series 10-30V 200mA Most quick disconnects Industry standard models
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Mounting
14.0mm (.55 in.) 15.0mm (.59 in.) 20.0mm (.78 in.) 22.0mm (.86 in.) 40.0mm (1.5 in.) Flush
Output Configuration
Connection
Cable (6ft.6in.) Quick Disconnect
Housing Material
Wires
Metal (BN) Brass Nickel Plated NonMetallic
Non-Flush
LED's Page
32/33
(ss)
Continued Page 14/15
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
CYLINDRICAL SENSORS SELECTION GUIDE (Cont.)
Sensing Distance (in.) Series
Weld-Immune 10-30V 200mA Resistant Electromagnetic Interference Teflon Plated 2-Wire 5-30V 100mA 10-55V 200mA Reduce Wiring Lower Cost Extended Range Plus 10-30V 200mA times improvement over Standard
Size (mm)
0.8mm (.03 in.)
1.0mm (.04
1.5mm (.06 in.)
2.0mm (.08 in.)
2.5mm (.10 in.)
3.0mm (.12 in.)
4.0mm (.16 in.)
5.0mm (.20 in.)
6.0mm (.23 in.)
7.0mm (.28 in.)
8.0mm (.32 in.)
10.0mm (.40 iin.)
12.0mm (.47 in.)
Namur Requires External Amplifier Energy Device Operates Hazardous Areas Analog 18-30V 1-9V Linear Output Detects Target Distance
CYLINDRICAL SENSORS SELECTION GUIDE
Sensing Distance (mm/in.) Series
Standard Series 90-250V Large Selection Quick Disconnects Outputs Extended Voltage, Metal 20-250V High Current Output Outputs Extended Voltage, Plastic 20-250V High Current Output Outputs Weld Immune 20-250V 300/ Resistance Electro magnetic interference Teflon Plated
Mounting
10mm 14.0mm 15.0mm (.40 in.) (.55 in.) (.59 in.) Flush Non-Flush
Size
0.8mm (.03 in.) 1.5mm (.06 in.) 2.0mm (.08 in.) 2.5mm (.10 in.) 4.0mm (.16 in.) 5.0mm (.20 in.) 7.0mm (.28 in.) 8.0mm (.32 in.)
Output Configuration
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Mounting
14.0mm (.55 in.) 15.0mm (.59 in.) 20.0mm (.78 in.) 22.0mm (.86 in.) 40.0mm (1.5 in.) Flush
Output Configuration
Connection
Cable (6ft.6in.) Quick Disconnect
Housing Material
Wires
Metal (BN) Brass Nickel Plated NonMetallic
Non-Flush
LED's
Page
Connection
Cable
Wires
Housing Material
Metal (BN) Plastic
LED's
Page
58/59 62/63 62/63
metal sensors have wire optional system ground.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA M12-M30 18-30V 120mA Output Energized
HOME
FIND
Short Body Sensors Economically priced Connector options Carries mark
(529)IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9981-2000
Non-Flush Mount
(.08 in.)
9981-2065
1.5mm (.06 in.)
9981-2064
Cable
9981-2200
9981-2264
9981-2265
Normally Open Normally Closed Normally Open Normally Closed
9981-2100
9981-2164
9981-2165
9981-2300
9981-2364
9981-2365
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
2.4V 2000Hz .15mm (.006 in.) PBTP
2.4V 2000Hz .15mm (.006 in.) PBTP
2.4V 2000Hz .15mm (.006 in.) PBTP
2.4V 2000Hz .20mm (.008 in.) PBTP
2.4V 2000Hz .20mm (.008 in.) PBTP
2.4V 2000Hz .20mm (.008 in.) PBTP
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
PORT
Style Connector 3-pin, Pico style, (.31 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
PORT
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
Metric/in. Conversion Table 12.0 23.0 24.0 28.0 29.0 =1.10 =1.14 30.0 34.0 35.0 39.0 40.0 50.0 1.18 1.34 1.37 1.53 1.57 1.96.in.
meter in.) Cable Assemblies Quick Disconnect Sensors
This table converts millimeters inches reference illustrations included these pages
Flush Mount
(.08 in.)
Cable
9982-2000
Non-Flush Mount
(.16 in.)
Cable
9982-2200
Connector 8000-5220 PVC, Straight Connector 8000-5230 PVC, Right Angle, 2LED, Connector 8000-5240 PVC, Right Angle, 2LED, Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED, Change last digit connector number meter cable Refer pages 116-121 more cable information
9982-2064
9982-2264
9982-2265
9982-2065
Mounting Brackets Page 114-115
9982-2100
9982-2164
9982-2165
9982-2300
9982-2364
9982-2365
1.5V 2000Hz .20mm (.008 in.) PBTP
1.5V 2000Hz .20mm (.008 in.) PBTP
1.5V 2000Hz .20mm (.008 in.) PBTP
1.5V 1000Hz .40mm (.016 in.) PBTP
1.5V 1000Hz .40mm (.016 in.) PBTP
1.5V 1000Hz .40mm (.016 in.) PBTP
Wiring Diagrams
Note; Wire colors applicable cables purchased from Altech.
Note: Sensor dimensions
Fixed Cable
Fixed Cable
LOAD LOAD
Normally Open
Normally Open
PORT
Connector
PORT
Connector
LOAD
LOAD
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Normally Open
Normally Open
Connector
Connector
LOAD
LOAD
Normally Open
Normally Open
PREVIOUS WIRE SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 18-30V 120mA Ouput Energized
HOME
FIND
(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Short Body Sensors Economically priced Connector options Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9984-2000
Non-Flush Mount
(.31in.)
Cable
9984-2200
(.20 in.)
9984-2065
9984-2265
Normally Open Normally Closed Normally Open Normally Closed
9984-2100
9984-2165
9984-2300
9984-2365
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
1.5V 1000Hz .50mm (.02 in.) PBTP
1.5V 1000Hz .50mm (.02 in.) PBTP
1.5V 500Hz .80mm (.031in.) PBTP
1.5V 500Hz .80mm (.031 in.) PBTP
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
Metric/in. Conversion Table 10.0 12.0 15.0 18.0 23.0 28.0 30.0 32.0 34.0 40.0 50.0 51.0 60.0 80.0 1.10 1.18 1.26 1.38 1.57 1.97 2.01 2.36 3.12
meter in.) Cable Assemblies Quick Disconnect Sensors
This table converts millimeters inches reference illustrations included these pages
Connector Connector Connector Connector
8000-5110 8000-5120 8000-5150 8000-5160
PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED,
Change last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
10mm (.39 in.)
Cable
9986-2000
Non-Flush Mount
15mm (.59 in.)
Cable
9986-2200
9986-2065
9986-2265
Mounting Brackets Pages 114-115
9986-2100
9986-2165
9986-2300
9986 -2365
1.5V 500Hz 1.0mm (.039 in.) PBTP
1.5V 500Hz 1.0mm (.039 in.) PBTP
1.5V 300Hz 1.5mm (.059 in.) PBTP
1.5V 300Hz 1.5mm (.059 in.) PBTP
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cables purchased from Altech
Fixed Cable
Fixed Cable
LOAD
LOAD
Normally Open
Normally Open
Connector
Connector
LOAD
LOAD
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Normally Open Normally Open
PREVIOUS WIRE SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-60V 400mA, LED's Operating Voltage Output Energized
HOME
FIND
Higher Current Output Higher Voltage Range Carries mark
(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9982-4000 9982-4400 9982-4100 9982-4500 2.4V 2000Hz .20mm (.008 in.) PBTP
Non-Flush Mount
(.16 in.)
Cable
9982-4200 9982-4600 9982-4300 9982-4700 2.4V 1000Hz .40mm (.016 in.) PBTP
(.08 in.)
9982-4064 9982-4464 9982-4164 9982-4564 2.4V 2000Hz .20mm (.008 in.) PBTP 9982-4065 9982-4465 9982-4165 9982-4565 2.4V 2000Hz .20mm (.008 in.) PBTP
9984-4264 9982-4664 9982-4364 9982-4764 2.4V 1000Hz .40mm (.016 in.) PBTP
9982-4265 9982-4665 9982-4365 9982-4765 2.4V 1000Hz .40mm (.016 in.) PBTP
Normally Open Normally Closed Normally Open Normally Closed
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
Style Connector 3-pin, Pico style, (.31 in.) supplied with Brass, Nickel Plated (BN) locknuts.
PREVIOUS
HOME
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table 12.0 18.0 .27.0 =1.06 29.0 35.0 45.0 50.0 60.0 80.0 1.14 1.37 1.77 1.97 2.36 3.15
This table converts millimeters inches reference illustrations included these pages
Connector Connector Connector
8000-5220 PVC, Straight 8000-5230 PVC, Right Angle, 2LED, 8000-5240 PVC, Right Angle, 2LED,
Flush Mount
(.20 in.)
Cable
9984-4000 9984-4400 9984-4100 9984-4500 2.4V 1000Hz .25mm (.01 in.) PBTP
Non-Flush Mount
(.31 in.)
Cable
9984-4200 9984-4600 9984-4300 9984-4700 2.4V 500Hz .40mm (.016 in.) PBTP
Connectors, Wire cable (PIN Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED, Connectors, Wire cable (PIN Connector 8000-5280 Right Angle
Change last digit connector number meter cable Refer pages 116-121 more cable information
9984-4065 9984-4465 9984-4165 9984-4565 2.4V 1000Hz .25mm (.01 in.) PBTP
9984-4265 9984-4665 9984-4365 9984-4765 2.4V 500Hz .40mm (.016 in.) PBTP
Mounting Brackets Pages 114-115
Wiring Diagrams
Note: Wire colors applicable cables purchased from Altech
Fixed Cable
LOAD
Fixed Cable
LOAD
Normally Open
Normally Open
Fixed Cable
LOAD
Fixed Cable
LOAD
Normally Closed
Normally Closed
Note: Sensor dimensions
Connector
LOAD
Connector
LOAD
Normally Open
Normally Open
Connector
LOAD
Connector
LOAD
Normally Closed
Normally Closed
Connector
Connector
LOAD
LOAD
Normally Open
Normally Open
Connector
LOAD
Connector
LOAD
Normally Closed
Normally Closed
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-60V 400mA LED's Operating Voltage Output Energized
HOME
FIND
(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Higher Current Output Higher Voltage Range Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9986-4000 9986-4400 9986-4100 9986-4500 10V-60V 2.4V
Non-Flush Mount
15mm (.59 in.)
Cable
9986-4200 9986-4600 9986-4300 9986-4700 2.4V .75mm (.030 in.) PBTB
10mm (.39 in.)
9986-4065 9986-4465 9986-4165 9986-4565 2.4V .50mm (.020 in.) PBTP
9986-4265 9986-4665 9986-4365 9986-4765 2.4V .75mm (.030 in.) PBTB
Normally Open Normally Closed Normally Open Normally Closed
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
.50mm (.020 in.)
PBTP
Note: Sensor dimensions
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors Connectors, Wire cable (PIN Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED, Connectors, 4PIN Wire cable (PIN Connectors 8000-5280 PVC, Right Angle
HOME
FIND
Metric/in. Conversion Table 12.0 23.0 35.0 1.37 45.0 1.77 50.0 1.96 60.0 2.36
This table converts millimeters inches reference illustrations included these pages
Change last digit connector number meter cable Refer pages 116-121 more cable information
Mounting Brackets Pages 114-115
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
LOAD
Fixed Cable
LOAD
Normally Open
Normally Open
Fixed Cable
LOAD
Fixed Cable
LOAD
Normally Closed
Normally Closed
Connector
Connector
LOAD
LOAD
Normally Open
Normally Open
Connector
LOAD
Connector
LOAD
Normally Closed
Normally Closed
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE STANDARD Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V Output Energized
HOME
FIND
(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Most complete range Fixed Cable Quick Disconnect Styles Available normally open (N.O.) normally closed (N.C.) output configuration Industry standard 10-30V operating voltage 200mA output current Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9961-0200 9961-4400 9961-0300 9961-4500 10V-30V 2.4V 2000 .15mm (.006 in.) PBTP 2.4V 2000 9961-0363
Non-Flush Mount
(.08 in.)
9961-0265 9961-4465 9961-0365 9961-4565 2.4V 2000
1.5mm (.06 in.)
9961-0263
9961-0264 9961-4464 9961-0364 9961-4564 2.4V 2000
Cable
9961-0400 9961-4600 9961-0500 9961-4700 2.4V 2000 .20mm (.008in.) PBTB
9961-0463
9961-0464 9961-4664
9961-0465 9961-4665 9961-0565 9961-4765 2.4V 2000 .20mm (.008in.) PBTB
Normally Open Normally Closed Normally Open Normally Closed
9961-0563
9961-0564 9961-4764
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
2.4V 2000
2.4V 2000
.15mm (.006 in.) .15mm (.006 in.) .15mm (.006in.) PBTP PBTP PBTP
.20mm (.008in.) .20mm (.008in.) PBTB PBTB
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
PORT
PORT
Style Connector 3-pin, Pico style, (.31 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. Connector clear, offering 360° viewing.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5220 PVC, Straight Connector 8000-5230 PVC, Right Angle, 2LED, Connector 8000-5240 PVC, Right Angle, 2LED, 63/65 Connectors, Wire cable (PIN 63/65 Connector 8000-5110 PVC, Straight 63/65 Connector 8000-5120 PVC, Right Angle 63/65 Connector 8000-5150 PVC, Right Angle, 2LED, 63/65 Connector 8000-5160 PVC, Right Angle, 2LED, 63/65 Connectors, 4PIN Wire cable (PIN 63/65 Connectors 8000-5280 PVC, Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information
Metric/in. Conversion Table 12.0 23.0 28.0 =1.10 29.0 34.0 35.0 40.0 43.0 50.0 60.0 1.14 1.34 1.37 1.57 1.69 1.47 2.36
This table converts millimeters inches reference illustrations included these pages
Flush Mount
(.08 in.)
Cable
9962-4000 9962-4400 9962-4100 9962-4500 2.4V 2000 2.4V 2000 9962-4163
Non-Flush Mount
(.16 in.)
9962-4065 9962-4465 9962-4165 9962-4565 2.4V 2000
9962-4063
9962-4064 9962-4464 9962-4164 9962-4564 2.4V 2000
Cable
9962-4200 9962-4600 9962-4300 9962-4700 2.4V 10µA 1000
9962-4263
9962-4264 9962-4664
9962-4265 9962-4665 9962-4365 9962-4765 2.4V 10µA 1000
Mounting Brackets Pages 114-115
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
9961-4363
9962-4364 9962-4764
2.4V 10µA 1000
2.4V 10µA 1000
Fixed Cable
LOAD
Fixed Cable
LOAD
Normally Open
Normally Open
Fixed Cable
LOAD
Fixed Cable
.20mm (.008in.) .20mm (.008in.) .20mm (.008in.) .20mm (.008in.) PBTB PBTB PBTB PBTB
.40mm (.016in.) .40mm (.016in.) .40mm (.016in.) .40mm (.016in.) PBTB PBTB PBTB PBTB
LOAD
Note: Sensor dimensions
Normally Closed
Normally Closed
Connector
LOAD
Connector
LOAD
Normally Open
Normally Open
Connector
LOAD
Connector
LOAD
PORT
PORT
Normally Closed
Normally Closed
63/65 Connector
63/65 Connector
©Altech
LOAD
LOAD
Normally Open
Normally Open
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
63/65 Connector
LOAD
Connector
LOAD
Normally Closed
Normally Closed
PREVIOUS WIRE STANDARD Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA, Output Energized
HOME
FIND
IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Most complete range Fixed Cable Quick Disconnect Styles Available normally open (N.O.) normally closed (N.C.) output configuration Industry standard 10-30V operating voltage 200mA output current Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9964-4000 9964-4400 9964-4100 9964-4500 2.4V 1000 .25mm (.01 in.) PBTP 2.4V 1000 .25mm (.01 in.) PBTP 9964-4163
Non-Flush Mount
(.31 in.)
9964-4065 9964-4465 9964-4165 9964-4565 2.4V 1000
(.20 in.)
9964-4063
Cable
9964-4200 9964-4600 9964-4300 9964-4700 2.4V .40mm (.016 in.) PBTB
9964-4263
9964-4265 9964-4665
Normally Open Normally Closed Normally Open Normally Closed
9964-4363
9964-4365 9964-4765
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
2.4V .40mm (.016 in.) PBTB
2.4V .40mm (.016 in.) PBTB
.25mm (.01 in.) PBTP
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.The Connector clear, offering 360° viewing.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
Metric/in. Conversion Table 10.0 12.0 15.0 18.0 23.0 28.0 30.0 32.0 34.0 40.0 50.0 51.0 60.0 80.0 1.10 1.18 1.26 1.34 1.57 1.97 2.01 2.36 3.12
meter in.) Cable Assemblies Quick Disconnect Sensors
This table converts millimeters inches reference illustrations included these pages
63/65 Connectors, Wire cable (PIN 63/65 Connector 8000-5110 PVC, Straight 63/65 Connector 8000-5120 PVC, Right Angle 63/65 Connector 8000-5150 PVC, Right Angle, 2LED, 63/65 Connector 8000-5160 PVC, Right Angle, 2LED, 63/65 Connectors, 4PIN Wire cable (PIN 63/65 Connectors 8000-5280 PVC, Right Angle
Change last digit connector number meter cable
Flush Mount
10mm (.39 in.)
Cable
9966-4000 9966-4400 9966-4100 9966-4500 2.4V .50mm (.02 in.) PBTB 2.4V .50mm (.02 in.) PBTB 9966-4163
Non-Flush Mount
15mm (.59 in.)
Cable
9966-4200 9966-4600 9966-4300 9966- 4700 2.4V 10µA .75mm (.03 in.) PBTB 2.4V 10µA .75mm (.03 in.) PBTB
Refer pages 116-121 more cable information
9966-4063
9966-4263
9966-4265 9966-4665 9966-4365 9966-4765 2.4V 10µA .75mm (.03 in.) PBTB
9966-4065 9966-4465 9966-4165 9966-4565 2.4V .50mm (.02 in.) PBTB
Mounting Brackets Pages 114-115
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Note: Sensor dimensions
Fixed Cable
Fixed Cable
LOAD
LOAD
Normally Open
Normally Open
Fixed Cable
Fixed Cable
LOAD
LOAD
Normally Closed
Normally Closed
63/65 Connector
63/65 Connector
LOAD
LOAD
Normally Open
Normally Open
63/65 Connector
LOAD
63/65 Connector
LOAD
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Normally Closed
Normally Closed
PREVIOUS WIRE EXTENDED SENSING DISTANCE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized
HOME
FIND
IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
times sensing distance over standard sensors Reduces accidental collisions Ideal applications where larger sensing distance required mounting space tight Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9981-4000
Non-Flush Mount
(.12 in.)
Cable
9981-4200
(.08 in.)
9981-4064 9981-4065
9981-4264
9981-4265
Normally Open Normally Closed Normally Open Normally Closed
9981-4100
9981-4164
9981-4165
9981-4300
9981-4364
9981-4365
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
10V-30V 2.4V 2000 .2mm (.008 in.) PBTP
2.4V 2000 .2mm (.008 in.) PBTP
2.4V 2000 .2mm (.008 in.) PBTP
2.4V 2000 .3mm (.012 in.) PBTB
2.4V 2000 .3mm (.012 in.) PBTB
2.4V 2000 .3mm (.012 in.) PBTB
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
Style Connector 3-pin, Pico style, (.31 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
50/65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Non-Metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table 12.0 23.0 27.0 28.0 =1.06 =1.10 29.0 30.0 34.0 35.0 40.0 50.0 1.14 1.18 1.33 1.37 1.57 1.96
This table converts millimeters inches reference illustrations included these pages
Connector Connector Connector
8000-5220 PVC, Straight 8000-5230 PVC, Right Angle, 2LED, 8000-5240 PVC, Right Angle, 2LED, PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED,
50/65 Connector 8000-5110 50/65 Connector 8000-5120 50/65 Connector 8000-5150 50/65 Connector 8000-5160
Flush Mount
(.16 in.)
Cable
9982-4900
Flush Mount
(.31 in.)
Cable
9984-4900
Change last digit connector number meter cable Refer pages 116-121 more cable information
9982-4950
9984-4950
Mounting Brackets Pages 114-115
12mA 2.4V 1500 .40mm (.016 in.) PBTB
2.4V 1500 .40mm (.016 in.) PBTB
2.4V 10µA .80mm (.03 in.) PBTB
2.4V 10µA .80mm (.03in.) PBTB
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Note: Sensor dimensions
Fixed Cable
LOAD
Fixed Cable
LOAD
Normally Open
Normally Open
Connector
LOAD
Connector
LOAD
Normally Open
Normally Open
50/65 Connector
50/65 Connector
LOAD
LOAD
Normally Open
Normally Open
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE EXTENDED SENSING DISTANCE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Ouput Energized
HOME
FIND
(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
times sensing distance over standard sensors Reduces accidental collisions Ideal applications where larger sensing distance required mounting space tight Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9966-3900
Metric/in. Conversion Table 30.0 50.0 60.0 80.0 1.20 1.47 2.36 3.12
15mm (.59 in.)
9966-3965
Normally Open Normally Closed Normally Open Normally Closed
This table converts millimeters inches reference illustrations included these pages
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
10V-30V 2.4V 1.5mm (.06 in.) PBTP
2.4V 1.5mm (.06 in.) PBTP
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED,
Change last digit connector number meter cable Refer pages 116-121 more cable information
Mounting Brackets Pages 114-115
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Fixed Cable
LOAD
Normally Open
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
Connector
LOAD
Normally Open
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE HIGH SPEED Brass, Nickel Plated (BN), Cylindrial,Threaded, 10-30V 200mA Output Energized
HOME
FIND
(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Metric/in. Conversion Table 40.0 45.0 50.0 65.0 1.57 1.77 1.96 2.55
Switching frequency 4000 Standard body length Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat.No. Cable
9962-2300
(.08 in.)
9962-2365
Normally Open
This table converts millimeters inches reference illustrations included these pages
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
10V-30V 2.4V 4000 .20mm (.008 in.) PBTP
2.4V 4000 .20mm (.008 in.) PBTP
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED,
Change last digit connector number meter cable Refer pages 116-121 more cable information
Mounting Brackets Pages 114-115
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Fixed Cable
LOAD
Normally Open
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
Connector
LOAD
Normally Open
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE PLASTIC METAL HOUSING Brass, Nickel Plated (BN), Plastic (TROGAMID Cylindrical,Threaded, 10-30V 400mA Output Energized
HOME
FIND
IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Metal plastic housings Higher output currents, 400mA Long body length Carries mark
Flush Mount
Sensing Distance
Cable Connector Cat.
Non-Flush Mount
(.16 in.)
Cable
9962-3300 9962-1600
Flush Mount
(.20 in.)
Cable
9964-3100 9964-1500
(.08 in.)
Cable
9962-3100 9962-1400
Normally Open Normally Closed Normally Open Normally Closed
9962-3200
9962-1500
9962-3400
9962-1700
9964-3200
9964-1600
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material
10-30V 2.4V 2000Hz .20mm (.008 in.) PBTB Trogamid
10-30V 2.4V 2000Hz .20mm (.008 in.) PBTB Nickel Plated Brass
10-30V 2.4V 1000Hz .40mm (.016 in.) PBTB Trogamid
10-30V 2.4V 1000Hz .40mm (.016 in.) PBTB Nickel Plated Brass
10-30V 2.4V 1000Hz .5mm (.02 in.) PBTB Trogamid
10-30V 2.4V 10mA 1000Hz .5mm (.02 in.) PBTB Nickel Plated Brass
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with non-metallic locknuts Trogamid housings, Brass, Nickel Plated (BN) locknuts Nickel Plated Brass housings.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
Metric/in. Conversion Table 12.0 18.0 30.0 =1.20 34.0 38.0 40.0 42.0 50.0 60.0 1.31 1.50 1.57 1.65 1.97 2.36
This table converts millimeters inches reference illustrations included these pages
Mounting Brackets Pages 114-115
Non-Flush Mount Flush Mount
(.31 in.)
Cable
9964-3300 9964-1700 9966-3100
Non-Flush Mount
15mm (.59 in.)
Cable
9966-3300 9966-1300
10mm (.39 in.)
Cable
9966-1100
9964-3400
9964-1800
9966-3200
9966-1200
9966-3400
9966-1400
10-30V 2.4V 10mA 500Hz .8mm (.03 in.) PBTB Trogamid
10-30V 2.4V 10mA 500Hz .8mm (.03 in.) PBTB Nickel Plated Brass
10-30V 2.4V 10mA 500Hz 1.0mm (.04 PBTB Trogamid
10-30V 2.4V 10mA 500Hz 1.0mm (.04 PBTB Nickel Plated Brass
10-30V 2.4V 10mA 300Hz 1.5mm (.06 PBTB Trogamid
10-30V 2.4V 10mA 300Hz 1.5mm (.06 PBTB Nickel Plated Brass
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
LOAD
Fixed Cable
LOAD
Normally Open
Normally Open
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE MINI METAL HOUSING Cylindrical, 10-30V 200mA Output Energized
HOME
FIND
IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
4mm, 5mm, 6.5mm diameter Economically Priced Non-connector models feature polyurethane (PUR) cables Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9980-1010
Flush Mount
0.8mm (0.03 in.)
Cable
9980-2010
0.8mm (0.03 in.)
9980-1064
9980-2064
Normally Open Normally Closed Normally Open Normally Closed
9980-1110
9980-1164
9980-2110
9980-2164
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material
10V-30V 5000 Typ.
5000 Typ. .04mm (.003 in.) PBTP Nickel Plated Brass
5000 Typ. .04mm (.003in.) PBTB Nickel Plated Brass
5000 Typ. .04mm (.003in.) PBTB Nickel Plated Brass
.04mm (.003 in.)
PBTP Nickel Plated Brass
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts model.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Fixed Cable in.).Supplied with Brass, Nickel Plated (BN) locknuts model.
PREVIOUS
HOME
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table .019in. 19.0 20.0 23.0 25.0 35.0 40.0 43.0 1.37 1.57 1.69
This table converts millimeters inches reference illustrations included this catalog
Connector Connector Connector
8000-5220 PVC, Straight 8000-5230 PVC, Right Angle, 2LED, 8000-5240 PVC, Right Angle, 2LED,
Change last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
1.5mm (0.06 in.)
Cable
9961-1200
Non-Flush Mount
3.0mm (0.11 in.)
Cable
9961-1300
9961-1264
9961-1364
Mounting Brackets Pages 114-115
2.4V 2000 .15mm (.006in.) PBTB Stainless Steel
2.4V 2000 .15mm (.006in.) PBTB Stainless Steel
2.4V 2000 .15mm (.006in.) PBTB Stainless Steel
2.4V 2000 .15mm (.006in.) PBTB Stainless Steel
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cabl;e purchased from Altech
Fixed Cable
LOAD
Fixed Cable
LOAD
Normally Open
Normally Open
Connector
Connector
LOAD
LOAD
Normally Open
Normally Open
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE COMPLEMENTARY OUTPUTS (N.O. N.C.) Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized
HOME
mark
FIND
Carries
IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9962-6200
Non-Flush Mount
(.16 in.)
Cable
9962-6300
(.08 in.)
9962-6265
9962-6365
(Complementary NO/NC) (Complementary NO/NC)
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
10V-30V 2.4V 2000
2.4V 2000 .20mm (.008 in.) PBTP
2.4V 1000 .40mm (.016 in.) PBTB
2.4V 1000 .40mm (.016 in.) PBTB
.20mm (.008 in.)
PBTP
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
PREVIOUS
HOME
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table 10.0 12.0 18.0 32.0 1.26 42.0 1.65 44.0 50.0 51.0 54.0 60.0 70.0 80.0 1.73 1.96 2.12 2.36 2.75 3.12
This table converts millimeters inches reference illustrations included these pages
Connectors, 4PIN Wire cable (PIN Connectors 8000-5280 PVC, Right Angle
Change last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
in.)
Cable
9964-6200
Non-Flush Mount
(.31 in.)
Cable
9964-6300
Mounting Brackets Pages 114-115
9964-6265
9964-6365
2.4V 1000 .5mm (.02 in.) PBTB
2.4V 1000 .5mm (.02 in.) PBTB
2.4V 10µA .8mm (.031 in.) PBTB
10µA .8mm (.031 in.) PBTB
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Cable Connector
(N.O.) (N.C.) LOAD
Connector
BK(N.O.)
LOAD
(N.C.)
LOAD
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE EXTENDED TEMPERATURE RANGE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized
HOME
FIND
Temperature Range: 100°C (104 212°F) Carries mark
IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9962-6010
Non-Flush Mount
(.16 in.)
Cable
9962-6110
(.08 in.)
9962-6065
9962-6165
Normally Open Normally Closed Normally Open Normally Closed
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
10V-30V 2.4V 2000
2.4V 2000 .20mm (.008 in.) PBTP
2.4V 1000 .40mm (.016 in.) PBTB
2.4V 1000 .40mm (.016 in.) PBTB
.20mm (.008 in.)
PBTP
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
Metric/in. Conversion Table 12.0 18.0 32.0 34.0 40.0 50.0 51.0 60.0 1.23 1.31 1.39 1.47 1.59 2.36
meter in.) Cable Assemblies Quick Disconnect Sensors
This table converts millimeters inches reference illustrations included these pages
Connector Connector Connector Connector
8000-5110 8000-5120 8000-5150 8000-5160
PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED,
Change last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
(.20 in.)
Cable
9964-6010
Non-Flush Mount
(.31 in.)
Cable
9964-6110
9964-6065
9964-6165
Mounting Brackets Pages 114-115
2.4V 1000 .50mm (.02 in.) PBTB
2.4V 1000 .50mm (.02 in.) PBTB
2.4V 10µA .80mm (.03 in.) PBTB
2.4V 10µA .80mm (.03 in.) PBTB
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
LOAD
Normally Open
Connector
LOAD
©Altech
Normally Open
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized
HOME
FIND
IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Circuitry that protects electro-magnetic interference Flush models have teflon ceramic coatings protect weld slag Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat.
Non-Flush Mount
(.16 in.)
Cable
9962-5900
(.08 in.)
Cable
9962-5840 9962-5845
9962-5965
Normally Open Normally Closed Normally Open Normally Closed
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material
10V-30V 2.4V
2.4V .20mm (.008 in.) Teflon Teflon Plated Brass
2.4V 15Hz .40mm (.016 in.) PBTB Nickel Plated Brass
2.4V .40mm (.016 in.) PBTB Nickel Plated Brass
.20mm (.008 in.)
Teflon Teflon Plated Brass
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
45/65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
Metric/in. Conversion Table 10.0 12.0 50.0 52.0 60.0 70.0 80.0 1.47 2.04 2.36 2.75 3.12
meter in.) Cable Assemblies Quick Disconnect Sensors
This table converts millimeters inches reference illustrations included these pages
45/65 Connector 8000-5110 45/65 Connector 8000-5120 45/65 Connector 8000-5150 45/65 Connector 8000-5160
PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED,
Change last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
(.20 in.)
Cable
9964-5840
Non-Flush Mount
(.31 in.)
Cable
9964-5900
Mounting Brackets Pages 114-115
9964-5845
9964-5965
2.4V .50mm (.02 in.) Teflon Teflon Plated Brass
2.4V .50mm (.02 in.) Teflon Teflon Plated Brass
2.4V 10µA .80mm (.03 in.) PBTB Nickel Plated Brass
2.4V 10µA .80mm (.03 in.) PBTB Nickel Plated Brass
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
LOAD
Normally Open
Connector
LOAD
Normally Open
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized
HOME
FIND
Circuitry that protects electro-magnetic interference Flush models have teflon ceramic coatings protect weld slag Carries mark
IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Flush Mount
Sensing Distance
Cable Connector Style Cat.
Non-Flush Mount
15mm (.59 in.)
Cable
9966-5900
10mm (.39 in.)
Cable
9966-5840
45/65
9966-5845
9966-5965
Normally Open Normally Closed Normally Open Normally Closed
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material
10V-30V 2.4V
2.4V 1.0mm (.039 in.) Teflon Teflon Plated Brass
2.4V 1.5mm (.059 in.) PBTB Nickel Plated Brass
2.4V 15Hz 1.5mm (.059 in.) PBTB Nickel Plated Brass
1.0mm (.039 in.)
Teflon Teflon Plated Brass
Note: Sensor dimensions
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
45/65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
Metric/in. Conversion Table 10.0 12.0 30.0 =1.20 60.0 2.36 80.0 3.15
HOME
FIND
This table converts millimeters inches reference illustrations included these pages
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors 45/65 Connector 8000-5110 45/65 Connector 8000-5120 45/65 Connector 8000-5150 45/65 Connector 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED,
Change last digit connector number meter cable Refer pages 116-121 more cable information
Mounting Brackets Pages 114-115
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
LOAD
Normally Open
Connector
LOAD
Normally Open
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS ANALOG SENSORS Cylindrical,Threaded Brass, Nickel Plated (BN), 18-30V Analog Output M12, M18, Digital Analog Output
HOME
FIND
IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Temperature Range: 70°C (-13 158°F)
Output voltage proportional target distance Ideal determining position information Excellent linearity Shielded cable ouputs cable models Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Voltage Range Supply Current Max. Load Current Max. Switching Frequency Temperature Drift Repeatability Front Material Output Voltage Range
Flush Mount
(.04 in.) (.16 in.)
Cable
9914-0900 ±0.3V PBTB 1-9V
0.5mm (.02 in.) 2.5mm (0.1 in.)
Cable
9914-0800 18V-30V ±0.3V
9914-0865 ±0.3V PBTP 1-9V
9914-0965 ±0.3V PBTB 1-9V
PBTP 1-9V
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
10.0 12.0 18.0 30.0
HOME
FIND
Accessories
Metric/in. Conversion Table =1.20 58.0 2.28 70.0 2.75 80.0 3.12 100.0mm 3.94
This table converts millimeters inches reference illustrations included these pages
meter in.) Cable Assemblies Quick Disconnect Sensors Connectors, 4PIN Wire cable (PIN Connectors 8000-5280 PVC, Right Angle
Change last digit connector number meter cable Refer pages 116-121 more cable information
Non-Flush Mount
(.28 in.) 14mm (.55 in.)
Cable
9914-1000 ±0.3V PBTB 1-9V Digital
Cable
9914-0500 ±0.3V PBTB 1-9V
9914-0565 ±0.3V PBTB 1-9V
analog output voltage digitized 8100-2100 switching unit 8100-2400/2500 modules. (Separate Accessory items refer pages more information.)
Mounting Brackets Pages 114-115
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Note: Sensor dimensions
Fixed Cable M12, M18,
SHIELD WIRE
LOAD
Fixed Cable
CONDUCTOR CABLE
GREY
DIG. OUTPUT
SHIELD WIRE
LOAD
65CN M12, M18,
LOAD
connected internally (Can used shield with shielded cable)
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS 3WIRE EXTENDED RANGE PLUS Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized
HOME
FIND
times sensing distance IEC(529) IP67 (NEMA Protection Sensing ranges from (.12 in.) Ideal applications where large 40mm (1.57 in.) sensors will Short Circuit Protection Carries mark
Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Flush Mount
Sensing distance
Cable Connector Style Cat. Cable
9981-5000
Non-Flush Mount
(0.2 in.)
9981-5065
(0.1 in.)
9981-5064
Cable
9981-5200
9981-5264
9981-5265
Normally Open Normally Closed Normally Open Normally Closed
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Housing Material Repeatability
10-30V 20mA 200mA 2.4V 100µA 1000Hz Nickel Plated Brass .15mm (.005 in.)
10-30V 20mA 200mA 2.4V 100µA 1000Hz Nickel Plated Brass .15mm (.005 in.)
10-30V 20mA 200mA 2.4V 100µA 1000Hz Nickel Plated Brass .15mm (.005 in.)
10-30V 20mA 200mA 2.4V 100µA 500Hz Nickel Plated Brass .3mm (.01 in.)
10-30V 20mA 200mA 2.4V 100µA 500Hz Nickel Plated Brass .3mm (.01 in.)
10-30V 20mA 200mA 2.4V 100µA 500Hz Nickel Plated Brass .3mm (.01 in.)
Fixed Cable in.). Supplied with Brass, Nickel Plated (BN) locknuts.
Connector 3-pin, Pico style, (.31 in.) supplied with Brass, Nickel Plated (BN) locknuts.
Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
12.0 40.0 44.0 45.0 50.0 1.39 1.73 1.77 1.97
HOME
52.0 54.0 56.0 58.0 60.0 62.0mm 66.0 70.0 2.04 2.12 2.20 2.28 2.36 2.44 2.60 2.75
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5220 PVC, Straight Connector 8000-5230 PVC, Right Angle, 2LED,PNP Connector 8000-5240 PVC, Right Anglr, LED, Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED Connector 8000-5160 PVC, Right Angle, 2LED
Metric/in. Conversion Table
This table converts millimeters inches reference illustrations included these pages
Flush Mount
(0.2 in.)
Cable
9982-5000
Non-Flush Mount
10mm (0.4 in.)
Cable
9982-5200
Change last digit connector number meter cable Refer pages 116-121 more cable information
Mounting Brackets Pages 114-115
9982-5065
9982-5265
Flush Installation Non-Flush Installation
10-30V 20mA 200mA 2.4V 100µA 800Hz Nickel Plated Brass .3mm (.01 in.)
10-30V 20mA 200mA 2.4V 100µA 800Hz Nickel Plated Brass .3mm (.01 in.)
10-30V 20mA 200mA 2.4V 100µA 400Hz Nickel Plated Brass .5mm (.02 in.)
10-30V 20mA 200mA 2.4V 100µA 400Hz Nickel Plated Brass .5mm (.02 in.)
0.2d
General Mounting must maintain minimum distance between adjacent opposite sensors addition non-target metals specified drawings above. Flush mount sensors must extend least times sensor diameter above adjacent metal housing. Non-flush mount sensors must extend distance greater than sensing distance (Sn). Please contact Altech installation assistance
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Note: Sensor dimensions
Fixed Cable
LOAD
Normally Open
Connector
LOAD
Normally Open
Connector
LOAD
Normally Open
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Metal Material
PREVIOUS 3WIRE EXTENDED RANGE PLUS Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized
HOME
FIND
times sensing distance Ideal applications where large sensors will Carries mark
IEC(529) IP67 (NEMA Protection Sensing ranges from (.12 in.) 40mm (1.57 in.) Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F)
Flush Mount
Sensing Distance
Cable Connector Style Cat. Cable
9984-5000
Non-Flush Mount
20mm (0.8 in.)
Cable
9984-5200
12mm (0.4 in.)
9984-5065
9984-5265
Normally Open Normally Closed Normally Open Normally Closed
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Housing Material Repeatability
10V-30V 2.4V Nickel Plated Brass 0.6mm (.02 in.)
2.4V Nickel Plated Brass 0.6mm (.02 in.)
2.4V Nickel Plated Brass (.04 in.)
2.4V
Nickel Plated Brass (.04 in.)
Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Fixed Cable in.). Supplied with Brass, Nickel Plated (BN) locknuts.
PREVIOUS
HOME
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table 12.0 40.0 44.0 45.0 50.0 1.57 1.73 1.77 1.97 52.0 54.0 56.0 58.0 60.0 62.0mm 66.0 70.0 2.04 2.12 2.20 2.28 2.36 2.44 2.60 2.75
This table converts millimeters inches reference illustrations included these pages
Connector Connector Connector Connector
8000-5110 8000-5120 8000-5150 8000-5160
PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED PVC, Right Angle, 2LED
Change last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
22mm (0.9 in.)
Cable
9986-5000
Non-Flush Mount
40mm (1.57 in.)
Cable
9986-5200
Mounting Brackets Pages 114-115
9986-5065
9986-5265
Flush Installation Non-Flush Installation
2.4V Nickel Plated Brass 1.1mm (.045 in.)
2.4V Nickel Plated Brass 1.1mm (.045 in.)
2.4V 100µA Nickel Plated Brass (.078 in.)
2.04V 100µA Nickel Plated Brass (.078 in.)
0.2d
Metal Material
General Mounting must maintain minimum distance between adjacent opposite sensors addition non-target metals specified drawings above. Flush mount sensors must extend least times sensor diameter above adjacent metal housing. Non-flush mount sensors must extend distance greater than sensing distance (Sn). Please contact Altech installation assistance
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
LOAD
Normally Open
Connector
LOAD
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Normally Open
PREVIOUS WIRE NAMUR Brass, Nickel Plated (BN), Plastic (TROGAMID-T) Cylindrical,Threaded
HOME
FIND
energy device Operates hazardous areas with external amplifier Meets NAMUR regulations 19234 specifications Carries mark
IEC(529) IP67 (NEMA Protection Reverse Polarity Protection Plastic Metal Housing according NAMUR Regulations 19234 Temperature Range: 70°C (-13 158°F) (For extended temperature models -40°C +125°C, consult Altech.)
Flush Mount
Sensing Distance
Cable Connector Style Cat. Nickel Plated Brass (BN) Plastic (TROGAMID Ripple Voltage Voltage Range (supplied Pulsotronic 8100-2200 Unit) Output Current with target detection) Output Current target detection) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
8.2V 8.2V 2000 .1mm (.004 in.) PBTP (Metal Housing)
Non-Flush Mount
(.08 in.)
Cable
9932-0200 9932-1600 8.2V 1000 .2mm (.008 in.) PBTP (Metal Housing) 8.2V
(.04 in.)
Cable
9932-0100
9932-0165
9932-0265
2000
1000 .2mm (.008 in.) PBTP (Metal Housing)
.1mm (.004 in.)
PBTP (Metal Housing)
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
12.0 23.0mm
HOME
24.0 25.0 28.0 30.0 40.0 50.0 1.16 1.20 1.57 1.97
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table
This table converts millimeters inches reference illustrations included these pages
Connectors, Wire cable (PIN Connector 8000-5280 Right Angle
Channge last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
(.08 in.)
Cable
9932-0300 9932-1100 8.2V 8.2V 2000 .2mm (.008 in.) PBTP (Metal Housing)
Non-Flush Mount
(.16 in.)
Cable
9932-0400 9932-1000 8.2V 1000 .4mm (.016 in.) PBTP (Metal Housing) 8.2V 1000 .4mm (.016 in.) PBTP (Metal Housing)
Remote Amplifier 8100-2200, page
9932-0365
9932-0465
Mounting Brackets Pages 114-115
2000 .2mm (.008 in.) PBTP (Metal Housing)
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
Remote Amplifier
Connector
Remote Amplifier
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE NAMUR Brass, Nickel Plated (BN), Plastic (TROGAMID-T) Cylindrical,Threaded
HOME
FIND
energy device Operates hazardous areas with external amplifier Meets NAMUR regulations 19234 specifications Carries mark
IEC(529) IP67 (NEMA Protection Reverse Polarity Protection Plastic Metal Housing according NAMUR Regulations 19234 Temperature Range: 70°C (-13 158°F)
Flush Mount
Sensing Distance
Cable Connector Style Cat. Nickel Plated Brass (BN) Plastic (TROGAMID Ripple Voltage Voltage Range (supplied Pulsotronic 8100-2200 Unit) Output Current with target detection) Output Current target detection) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Cable
9932-0500 9932-1300 8.2V 1000 8.2V 1000 .5mm (.02 in.) PBTP (Metal Housing)
Non-Flush Mount
(.31 in.)
Cable
9932-0600 9932-1200 8.2V .8mm (.03 in.) PBTP (Metal Housing) 8.2V .8mm (.03 in.) PBTP (Metal Housing)
(.20 in.)
9932-0565
9932-0665
.5mm (.02 in.)
PBTP (Metal Housing)
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
Metric/in. Conversion Table 12.0 18.0 22.0 28.0 30.0 40.0 50.0 51.0 60.0 1.16 1.20 1.57 1.96 2.00 2.36
meter in.) Cable Assemblies Quick Disconnect Sensors
This table converts millimeters inches reference illustrations included these pages
Connectors, Wire cable (PIN Connector 8000-5280 Right Angle
Change last digit connector number meter cable Refer page 116-121 more cable information
Flush Mount
10mm (.39 in.)
Cable
9932-0700 9932-1500 8.2V .1mm (.039 in.) PBTP (Metal Housing) 8.2V .1mm (.039 in.) PBTP (Metal Housing)
Non-Flush Mount
15mm (.59 in.)
Cable
9932-0800 9932-1400 8.2V 1.5mm (.059 in.) PBTP (Metal Housing) 8.2V 1.5mm (.059 in.) PBTP (Metal Housing)
9932-0765
9932-0865
Remote Amplifier 8100-2200, page
Mounting Brackets Pages 114-115
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
Remote Amplifier
Connector
Remote Amplifier
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE SENSORS Brass, Nickel Plated (BN), Cylindrical,Threaded, 5-30V 100mA M18, 10-55V Output Energized
HOME
FIND
Wire devices reduce wiring requirements Economically Priced Carries mark
IEC(529) IP67 (NEMA Protection Reverse Polarity Protection Temperature Range: 70°C (-13 158°F)
Flush Mount
Sensing distance
Cable Connector Style Cat. Normally Open Normally Closed
Non-Flush Mount
(.16 in.)
Cable
9962-5700
Flush Mount
(0.2 in.)
Cable
9964-5400
(.08 in.)
Cable
9962-5600
9962-5665
9962-5765
Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material
5V-30V 100mA 0.5mA 500Hz .20mm (.008 in.) PBTP
5V-30V 100mA 0.5mA 500Hz .20mm (.008 in.) PBTP
5V-30V 100mA 0.5mA 500Hz .40mm (.016 in.) PBTP
5V-30V 100mA 0.5mA 500Hz .40mm (.016 in.) PBTP
10V-55V 200mA 6.5V 1.5mA 1000Hz .40mm (.016 in.) PBTP
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
10.0 12.0 15.0 18.0
HOME
23.0 28.0 30.0 32.0 34.0 40.0 50.0 51.0 60.0 80.0 1.10 1.18 1.26 1.34 1.57 1.97 2.01 2.36 3.12
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table
This table converts millimeters inches reference illustrations included these pages
Connector Connector
8000-5110 PVC, Straight 8000-5120 PVC, Right Angle
Change last digit connector number meter cable Refer pages 116-121 more cable information
Non-Flush Mount Flush Mount Non-Flush Mount
(.31 in.)
Cable
9964-5500
Mounting Brackets Pages 114-115
10mm (.39 in.)
Cable
9966-5400
15mm (.59 in.)
Cable
9966-5500
10V-55V 200mA 6.5V 1.5mA 500Hz .80mm (.03 in.) PBTP
10V-55V 200mA 6.5V 1.5mA 500Hz (.039 in.) PBTP
10V-55V 200mA 6.5V 1.5mA 300Hz 1.5mm (.059 in.) PBTP
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
LOAD
Connector
LOAD
©Altech
Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE STANDARD SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 90-250V Output Energized
HOME
FIND
(529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F)
Most complete range Fixed Cable Quick Disconnect Styles Available normally open (N.O.) normally closed (N.C.) output configuration This series features 360° viewing connector type "67" Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current (20ms 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Cable
9952-0500
Non-Flush Mount
(.16 in.)
9952-0568
(.08 in.)
9952-0562
66/67
9952-0566 9952-0567
Cable
9952-0400
9952-0462
66/67
9952-0466 9952-0467
9952-0468
9952-0900
9952-0966 9952-0967
9952-0968
9952-0800
9952-0866 9952-0867
9952-0868
90V-250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .2mm (.008in.) PBTP
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .2mm (.008in.) PBTP
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .2mm (.008in.) PBTP
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .2mm (.008in.) PBTP
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V
250V 50/60Hz 3mA/220V
250V 50/60Hz 3mA/220V
1.5mA/110V 1.5mA/110V 15Hz/220V 15Hz/220V
.4mm (.016in.) .4mm (.0016in.) .4mm (.016in.) .4mm (.016in.) PBTB PBTB PBTB PBTB
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Style Connector 3-pin, Mini style, 25mm (1.0 in.) supplied with Brass, Nickel Plated (BN) locknuts.
66/67/68 Style Connectors 66/67 connectors 4-pin, connector, 3-pin), Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. Connector clear, offering 360° viewing.
(66/68
(66/68
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
12.0 23.0 28.0 =1.10
HOME
29.0 34.0 35.0 40.0 43.0 50.0 60.0 1.14 1.34 1.37 1.57 1.69 1.47 2.36
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5030 66/67 Connector 8000-5060 66/67 Connector 8000-5070 Connector 8000-5130 Connector 8000-5140 PVC, Straight PVC, Right Angle PVC, Straight Straight Right Angle
Metric/in. Conversion Table
This table converts millimeters inches reference illustrations included these pages
Change last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
(0.2 in.)
Cable
9954-2200
Non-Flush Mount
(.31 in.)
9954-2268
Mounting Brackets Pages 114-115
9954-1968
9954-2262
66/67
9954-2266 9954-2267
Cable
9954-1900
9954-1962
66/67
9954-1966 9954-1967
9954-2600
9954-2666 9954-2667
9954-2668
9954-2500
9954-2568
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .8mm (.031in.) PBTB
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .8mm (.031in.) PBTB
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .8mm (.031in.) PBTB
250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .8mm (.031in.) PBTB
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
Note: Sensor dimensions
Fixed Cable
LOAD Yellow/GRN
LOAD Yellow/GRN
Normally Open
Normally Closed
Connector
LOAD
Normally Open
66/67 Connector
Yell/GRN
66/67 Connector
Yell/GRN
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
LOAD
LOAD
Normally Open
Normally Closed
(66/68
(66/68
Connector
Red/WHT LOAD
Connector
Red/WHT LOAD
Normally Open
Normally Closed
PREVIOUS WIRE STANDARD SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 90-250V Output Energized
HOME
FIND
(529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F)
Most complete range Fixed Cable Quick Disconnect Styles Available normally open (N.O.) normally closed (N.C.) output configuration This series features 360° viewing connector type "67" Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Short Term Current (20ms 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Cable
9956-1500
10mm (.39 in.)
9956-1562
9956-1566
9956-1567
9956-1568
9956-1900
9956-1968
250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTP
250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTP
250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTP
250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTP
250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTB
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Style Connector 3-pin, Mini style, 25mm (1.0 in.) supplied with Brass, Nickel Plated (BN) locknuts.
(66/68
66/67/68 Style Connectors 66/67 connectors 4-pin, connector, 3-pin), Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts Connector clear, offering 360° viewing.
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
12.0 23.0 28.0 =1.10
HOME
29.0 34.0 35.0 40.0 43.0 50.0 60.0 1.14 1.34 1.37 1.57 1.69 1.97 2.36
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5030 66/67 Connector 8000-5060 66/67 Connector 8000-5070 Connector 8000-5130 Connector 8000-5140 PVC, Straight PVC, Right Angle PVC, Straight Straight Right Angle
Metric/in. Conversion Table
This table converts millimeters inches reference illustrations included these pages
Change last digit connector number meter cable Refer pages 116-121 more cable information
Non-Flush Mount
15mm (0.59 in.)
Cable
9956-1400
Mounting Brackets Pages 114-115
9956-1467
9956-1462
9956-1466
9956-1468
9956-1800
9956-1868
250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V 1.5mm (.0596in.) PBTB
250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V 1.5mm (.059 in.) PBTB
250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V .4mm (.016in.) PBTB
50/60Hz 3A/220V 1.5mA/110V 15Hz/220V .4mm (.016in.) PBTB
250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
Note: Sensor dimensions
Fixed Cable
LOAD Yellow/GRN
LOAD Yellow/GRN
Normally Open
Normally Closed
Connector
LOAD
Normally Open
66/67 Connector
66/67 Connector
Yell/GRN
Yell/GRN
Connector
Red/WHT LOAD
©Altech
Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
LOAD
LOAD
Normally Open
(66/68
Normally Closed
Connector
Red/WHT LOAD
Normally Open
Normally Closed
PREVIOUS WIRE EXTENDED VOLTAGE RANGE Brass, Nickel Plated (BN), TROGAMID Cylindrical,Threaded, 20-250V Output Energized
HOME
FIND
(529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F)
Higher Current Rating Wider Voltage Range Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material Cable
9924-0500
Non-Flush Mount
(.16 in.)
Cable
9924-0700
(.08 in.)
Cable
9924-1100 9924-0568
Cable
9924-1000
9924-0768
9924-0400
9924-1300
9924-0468
9924-0900
9924-1200
9924-0968
20V-250V 50/60Hz 15Hz .20mm (.008 in.) PBTP Nickel Plated Brass
250V 50/60Hz 15Hz .20mm (.008 in.) PBTP Trogamid
250V 50/60Hz 15Hz .20mm (.008 in.) PBTP Nickel Plated Brass
250V 50/60Hz 15Hz .40mm (.016 in.) PBTB Nickel Plated Brass
250V 50/60Hz 15Hz .40mm (.016 in.) PBTB Trogamid
250V 50/60Hz 15Hz .40mm (.016 in.) PBTB Nickel Plated Brass
Nickel Plated Brass Housings Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with non-metallic locknuts Trogamid housings Nickel Plated (BN) locknuts Nickel Plated Brass housings. Trogamid Housings
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Style Connectors 3-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
PREVIOUS
HOME
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table 12.0 54.0 =2.12 60.0 64.0 70.0 80.0 2.36 2.52 2.75 3.15
This table converts millimeters inches reference illustrations included these pages
Connector Connector
8000-5130 Straight 8000-5140 Right Angle
Change last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
(0.2 in.)
Cable
9921-1200
Non-Flush Mount
(0.3 in.)
Cable
9921-1500
Mounting Brackets Pages 114-115
Cable
9921-2000
Cable
9921-2200
9921-1568
9921-1268
9921-1300
9921-2100
9921-1368
9921-1700
9921-2300
9921-1768
250V 50/60Hz 15Hz .50mm (.02 in.) PBTB Nickel Plated Brass
250V 50/60Hz 15Hz .50mm (.02 in.) PBTB Trogamid
250V 50/60Hz 15Hz .50mm (.02 in.) PBTB Nickel Plated Brass
250V 50/60Hz 15Hz .8mm (.039 in.) PBTB Nickel Plated Brass
250V 50/60Hz 15Hz .8mm (.039 in.) PBTB Trogamid
250V 50/60Hz 15Hz .8mm (.039 in.) PBTB Nickel Plated Brass
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
Note: Sensor dimensions
Fixed Cable
LOAD Yellow/GRN LOAD Yellow/GRN
Normally Open
Normally Closed
Fixed Cable
Fixed Cable
LOAD
LOAD
Normally Open
Normally Closed
Connector
Red/WHT
Connector
Red/WHT LOAD
LOAD
Normally Open
Normally Closed
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE EXTENDED VOLTAGE RANGE Brass, Nickel Plated (BN), TROGAMID Cylindrical,Threaded, 20-250V Output Energized
HOME
FIND
(529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F)
Higher Current Rating Wider Voltage Range Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Normally Open Cable
9916-2600
10mm (0.39 in.)
Cable
9916-2900
9916-2668
Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material
9916-2100
9916-2400
9916-2168
20V-250V 50/60Hz 15Hz (.039 in.) PBTP Nickel Plated Brass
250V 50/60Hz 15Hz (.039 in.) PBTP Trogamid
250V 50/60Hz 15Hz (.039 in.) PBTP Nickel Plated Brass
Nickel Plated Brass Housings Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with non-metallic locknuts Trogamid housings Brass, Nickel Plated (BN) locknuts Nickel Plated Brass housings. Trogamid Housings
Style Connectors 3-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table 12.0 30.0 38.0 48.0 =1.18 =1.50 =1.89 50.0 58.0 60.0 80.0 1.96 2.28 2.36 3.15
This table converts millimeters inches reference illustrations included these pages
Connector Connector
8000-5130 Straight 8000-5140 Right Angle
Change last digit connector number meter cable Refer pages 116-121 more cable information
Non-Flush Mount
15mm (0.59 in.)
Cable
9916-2700
Mounting Brackets Pages 114-115
Cable
9916-3000
9916-2768
9916-2300
9916-2500
9916-2368
250V 50/60Hz 15Hz 1.5mm (.059 in.) PBTB Nickel Plated Brass
250V 50/60Hz 15Hz 1.5mm (.059 in.) PBTB Trogamid
250V 50/60Hz 15Hz 1.5mm (.059 in.) PBTB Nickel Plated Brass
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Note: Sensor dimensions
Fixed Cable Fixed Cable
LOAD Yellow/GRN
LOAD Yellow/GRN
Normally Open
Normally Closed
Fixed Cable
Fixed Cable
LOAD
LOAD
Normally Open
Normally Closed
Connector
Red/WHT
Connector
Red/WHT LOAD
LOAD
Normally Open
Normally Closed
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS WIRE WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 20-250V 300mA/500mA Output Energized
HOME
FIND
IEC(529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F)
Circuitry that protects electro-magnetic interference Flush models have teflon ceramic coatings protect weld slag Carries mark
Flush Mount
Sensing Distance
Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current 1Hz) Switching Frequency Resistance Load Hysterisis Temperature Drift Repeatability Front Material Housing Material
9952-5840
Non-Flush Mount
(.16 in.)
Cable
9952-5900
(.08 in.)
Cable
9952-5848
9952-5968
9952-5640
9952-5648
9952-5700
9952-5768
20V-250V 50/60Hz
250V 50/60Hz .10mm (.004 in.) Teflon Teflon Plated Brass
250V 50/60Hz 15Hz .2mm (.008 in.) PBTB Nickel Plated Brass
250V 50/60Hz .2mm (.008 in.) PBTB Nickel Plated Brass
.10mm (.004 in.)
Teflon Teflon Plated Brass
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
48/68 Style Connector 3-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
PREVIOUS
HOME
FIND
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors
Metric/in. Conversion Table 10.0 12.0 18.0 60.0 70.0 80.0 =2.36 =2.75 =3.15
This table converts millimeters inches reference illustrations included these pages
48/68 Connector 8000-5130 PVC, Straight 48/68 Connector 8000-5140 Right Angle
Change last digit connector number meter cable Refer pages 116-121 more cable information
Flush Mount
(.20 in.)
Cable
9954-5840
Non-Flush Mount
(.31 in.)
Mounting Brackets Pages 114-115
9954-5968
9954-5848
Cable
9954-5900
9954-5640
9954-5648
9954-5700
9954-5768
250V 50/60Hz .25mm (.01 in.) Teflon Teflon Plated Brass
250V 50/60Hz .25mm (.01 in.) Teflon Teflon Plated Brass
250V 50/60Hz .4mm (.016 in.) PBTB Nickel Plated Brass
250V 50/60Hz .4mm (.016 in.) PBTB Nickel Plated Brass
Note: Sensor dimensions
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
LOAD
Yellow/GRN
Normally Open
48/68 Connector
Red/WHT
LOAD
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
Normally Open
PREVIOUS WIRE WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 20-250V 300/500mA Output Energized
HOME
FIND
Circuitry that protects electro-magnetic interference Flush models have teflon ceramic coatings protect weld slag Carries mark
IEC(529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F)
Flush Mount
Sensing Distance
Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current 1Hz) Switching Frequency Resistance Load Hysterisis Temperature Drift Repeatability Front Material Housing Material
9956-5840
Non-Flush Mount
15mm (.59 in.)
Cable
9956-5900
10mm (.39 in.)
Cable
9956-5848
9956-5968
9956-5640
9956-5648
9956-5700
9956-5768
20V-250V 50/60Hz .5mm (.02 in.) Teflon Teflon Plated Brass
250V 50/60Hz .5mm (.02 in.) Teflon Teflon Plated Brass
250V 50/60Hz .75mm (.03 in.) PBTB Nickel Plated Brass
250V 50/60Hz 15Hz .75mm (.03 in.) PBTB Nickel Plated Brass
Note: Sensor dimensions
Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts.
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490
48/68 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.
PREVIOUS
Metric/in. Conversion Table 10.0 12.0 30.0 80.0 =1.18 =3.15
HOME
FIND
This table converts millimeters inches reference illustrations included these pages
Accessories
meter in.) Cable Assemblies Quick Disconnect Sensors 48/68 Connector 8000-5130 PVC, Straight 48/68 Connector 8000-5140 Right Angle
Change last digit connector number meter cable Refer pages 116-121 more cable information
Mounting Brackets Pages 114-115
Wiring Diagrams
Note: Wire colors applicable cable purchased from Altech
Fixed Cable
LOAD Yellow/GRN
Normally Open
48/68 Connector
Red/WHT LOAD
Normally Open
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490

Other recent searches


Q85VR3DLB - Q85VR3DLB   Q85VR3DLB Datasheet
PS21963-T - PS21963-T   PS21963-T Datasheet
MN103S5405YD - MN103S5405YD   MN103S5405YD Datasheet
ML9059 - ML9059   ML9059 Datasheet
IDT74FST163213 - IDT74FST163213   IDT74FST163213 Datasheet
IB0016 - IB0016   IB0016 Datasheet
DG485 - DG485   DG485 Datasheet
ADRF6601 - ADRF6601   ADRF6601 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive