| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
CLICK FILE OVERVIEW Inductive Proximity Sensors Introduction
Top Searches for this datasheetFIND CLICK FILE OVERVIEW Inductive Proximity Sensors Introduction Operation CLICK FILE CYLINDRICAL Inductive Proximity Sensors Introduction/Operation Selection Guide, styles.12 Selection Guide, styles Product Specifications.16 LIMIT STYLE Inductive Proximity Sensors Introduction/Operation Selection Guide.71 Product Specifications.72 CLICK FILE BLOCK STYLE Inductive Proximity Sensors Introduction/Operation Selection Guide.82 Product Specifications.84 CLICK FILE RING STYLE Inductive Proximity Sensors Introduction/Operation Selection Guide.100 Product Specifications.102 CLICK FILE ACCESSORIES Inductive Proximity Sensors Introduction .113 Mounting Brackets .114 Cable Assemblies.116 Switching Units.122 Motion Detectors.128 OTHER INFORMATION APPENDIX: Codes .132 NEMA requirements .133 Cross Reference .134 Glossary.135 Conversion Charts .137 INDEX .138 TERMS CONDITIONS .141 WARRANTY.143 CLICK FILE specifications subject change without notice obligation Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Cylindrical Sensors Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS CYLINDRICAL INDUCTIVE PROXIMITY SENSORS Altech Cylindrical sensors available diameters ranging from (.16 in.) 30mm (1.18 in.) with sensing distances 40mm (1.57 in.). Most models feature nickel plated brass (BN) housing, stainless steel (SS) non-metallic versions available. Both flush mount non-flush mount sensors available. Flush mount versions often called shielded embeddable. Non-flush mount sensors also called non-shielded nonembeddable. Non-flush sensors have larger sensing distances than their flush mount counterparts. Inductive sensors meet IP67 (NEMA1, protection levels. Please refer pages 132-133 this catalog more information. HOME FIND Sensing Distances Cylindrical Style Sensors Type Series Short Body Series Standard Series Extended Sensing Range High Speed Plastic Metal Housing Mini Housing Complementary Output Extended Temperature Range Weld Immune Analog Output Extended Range Plus 2-Wire Namur Voltage Flush* Non-Flush* FLUSH MOUNT CYLINDRICAL SENSORS Flush Mounted, sometimes called embedded shielded sensors, have electromagnetic fields concentrated directly front sensing heads mounted directly into metal mounting brackets embedded directly into metal without causing false output. Figure also illustrates that Cylindrical Flush Mount sensors there should least diameter distance between adjacent sensors, non-target metal surfaces should less than times sensing distance directly across from sensing head. Also, directly opposite sensors mounted metal should greater than times sensing distance apart. *All Sensing Distances Operating Voltages Cylindrical Style 250VAC 30VDC 250VAC 30VDC 60VDC Operating Current- Cylindrical Style 200mA Sensor Wiring Systems Cylindrical Style 2-Wire 2-Wire 3-Wire 4-Wire Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS NON-FLUSH CYLINDRICAL SENSORS Sometimes called non-embedded non-shielded, non-flush sensors have electromagnetic fields with wide sensing angle unshielded metal surrounding sensing head). Care must taken insure that non-target metal comes near proximity sensing head. Distances demonstrated Figure Adjacent sensors should separated least times diameter. Non-target metal should least times sensing distance directly across from sensing head. directly opposite sensors should least times sensing distance apart. OUTPUT CONNECTIONS AC,DC Normally Open (NO), Normally Closed (NC). Namur Special interface Circuits required. Analog Analog Output OUTPUT CABLES Cylindrical Sensors provided with meter fixed cables. meter PVC, meter cables optional specified selection last digits part number. chart below. Cable Length Material Part Last Digits HOME FIND Fig. CYLINDRICAL SENSOR INSTALLATION Flush Mount Installation (Mild Steel) Non-Flush Mount Installation (Mild Steel) Opposing Installation (Mild Steel) Quick Disconnect models designed user-friendly simplify installations. Please product specification sensors with quick disconnect connectors matching cable assemblies pages accessory section. QUICK DISCONNECT HOUSING MATERIALS CONNECTORS Pulostronic sensors available Nickel Plated Brass Trogamid wide selection Quick Teflon Plated Brass Disconnect styles circuits. While virtually sensor Nickel Plated Brass custom manufactured with Trogamid Quick Disconnect connector, Altech Teflon Plated Brass offers largest selection Stainless Steel standard Quick Disconnect models. Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND CYLINDRICAL SENSORS SELECTION GUIDE Sensing Distance (in.) Series Size (mm) Extended Sensing 10-30V 200mA improvement over Standard Metal Plastic 10-30V 400mA Extended Length Higher Current Output Mini Housing 10-30V 200mA 6.5mm diameter Includes Complementary Switching Output 10-30V 200mA Outputs High Speed 10-30V 200mA 4,000 Switching Frequency Extended Temperature 10-30V 200mA -40°C 100°C Dia. 6.5mm Dia. 0.8mm (.03 in.) 1.0mm (.04 1.5mm (.06 in.) 2.0mm (.08 in.) 2.5mm (.10 in.) 3.0mm (.12 in.) 4.0mm (.16 in.) 5.0mm (.20 in.) 6.0mm (.23 in.) 7.0mm (.28 in.) 8.0mm (.32 in.) 10.0mm (.40 iin.) 12.0mm (.47 in.) Series 18-30V 120mA Short Body Economically priced Series 10-60V 400mA LED's models Standard Series 10-30V 200mA Most quick disconnects Industry standard models ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Mounting 14.0mm (.55 in.) 15.0mm (.59 in.) 20.0mm (.78 in.) 22.0mm (.86 in.) 40.0mm (1.5 in.) Flush Output Configuration Connection Cable (6ft.6in.) Quick Disconnect Housing Material Wires Metal (BN) Brass Nickel Plated NonMetallic Non-Flush LED's Page 32/33 (ss) Continued Page 14/15 ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND CYLINDRICAL SENSORS SELECTION GUIDE (Cont.) Sensing Distance (in.) Series Weld-Immune 10-30V 200mA Resistant Electromagnetic Interference Teflon Plated 2-Wire 5-30V 100mA 10-55V 200mA Reduce Wiring Lower Cost Extended Range Plus 10-30V 200mA times improvement over Standard Size (mm) 0.8mm (.03 in.) 1.0mm (.04 1.5mm (.06 in.) 2.0mm (.08 in.) 2.5mm (.10 in.) 3.0mm (.12 in.) 4.0mm (.16 in.) 5.0mm (.20 in.) 6.0mm (.23 in.) 7.0mm (.28 in.) 8.0mm (.32 in.) 10.0mm (.40 iin.) 12.0mm (.47 in.) Namur Requires External Amplifier Energy Device Operates Hazardous Areas Analog 18-30V 1-9V Linear Output Detects Target Distance CYLINDRICAL SENSORS SELECTION GUIDE Sensing Distance (mm/in.) Series Standard Series 90-250V Large Selection Quick Disconnects Outputs Extended Voltage, Metal 20-250V High Current Output Outputs Extended Voltage, Plastic 20-250V High Current Output Outputs Weld Immune 20-250V 300/ Resistance Electro magnetic interference Teflon Plated Mounting 10mm 14.0mm 15.0mm (.40 in.) (.55 in.) (.59 in.) Flush Non-Flush Size 0.8mm (.03 in.) 1.5mm (.06 in.) 2.0mm (.08 in.) 2.5mm (.10 in.) 4.0mm (.16 in.) 5.0mm (.20 in.) 7.0mm (.28 in.) 8.0mm (.32 in.) Output Configuration ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Mounting 14.0mm (.55 in.) 15.0mm (.59 in.) 20.0mm (.78 in.) 22.0mm (.86 in.) 40.0mm (1.5 in.) Flush Output Configuration Connection Cable (6ft.6in.) Quick Disconnect Housing Material Wires Metal (BN) Brass Nickel Plated NonMetallic Non-Flush LED's Page Connection Cable Wires Housing Material Metal (BN) Plastic LED's Page 58/59 62/63 62/63 metal sensors have wire optional system ground. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA M12-M30 18-30V 120mA Output Energized HOME FIND Short Body Sensors Economically priced Connector options Carries mark (529)IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9981-2000 Non-Flush Mount (.08 in.) 9981-2065 1.5mm (.06 in.) 9981-2064 Cable 9981-2200 9981-2264 9981-2265 Normally Open Normally Closed Normally Open Normally Closed 9981-2100 9981-2164 9981-2165 9981-2300 9981-2364 9981-2365 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 2.4V 2000Hz .15mm (.006 in.) PBTP 2.4V 2000Hz .15mm (.006 in.) PBTP 2.4V 2000Hz .15mm (.006 in.) PBTP 2.4V 2000Hz .20mm (.008 in.) PBTP 2.4V 2000Hz .20mm (.008 in.) PBTP 2.4V 2000Hz .20mm (.008 in.) PBTP Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. PORT Style Connector 3-pin, Pico style, (.31 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. PORT Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories Metric/in. Conversion Table 12.0 23.0 24.0 28.0 29.0 =1.10 =1.14 30.0 34.0 35.0 39.0 40.0 50.0 1.18 1.34 1.37 1.53 1.57 1.96.in. meter in.) Cable Assemblies Quick Disconnect Sensors This table converts millimeters inches reference illustrations included these pages Flush Mount (.08 in.) Cable 9982-2000 Non-Flush Mount (.16 in.) Cable 9982-2200 Connector 8000-5220 PVC, Straight Connector 8000-5230 PVC, Right Angle, 2LED, Connector 8000-5240 PVC, Right Angle, 2LED, Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED, Change last digit connector number meter cable Refer pages 116-121 more cable information 9982-2064 9982-2264 9982-2265 9982-2065 Mounting Brackets Page 114-115 9982-2100 9982-2164 9982-2165 9982-2300 9982-2364 9982-2365 1.5V 2000Hz .20mm (.008 in.) PBTP 1.5V 2000Hz .20mm (.008 in.) PBTP 1.5V 2000Hz .20mm (.008 in.) PBTP 1.5V 1000Hz .40mm (.016 in.) PBTP 1.5V 1000Hz .40mm (.016 in.) PBTP 1.5V 1000Hz .40mm (.016 in.) PBTP Wiring Diagrams Note; Wire colors applicable cables purchased from Altech. Note: Sensor dimensions Fixed Cable Fixed Cable LOAD LOAD Normally Open Normally Open PORT Connector PORT Connector LOAD LOAD ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Normally Open Normally Open Connector Connector LOAD LOAD Normally Open Normally Open PREVIOUS WIRE SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 18-30V 120mA Ouput Energized HOME FIND (529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Short Body Sensors Economically priced Connector options Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9984-2000 Non-Flush Mount (.31in.) Cable 9984-2200 (.20 in.) 9984-2065 9984-2265 Normally Open Normally Closed Normally Open Normally Closed 9984-2100 9984-2165 9984-2300 9984-2365 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 1.5V 1000Hz .50mm (.02 in.) PBTP 1.5V 1000Hz .50mm (.02 in.) PBTP 1.5V 500Hz .80mm (.031in.) PBTP 1.5V 500Hz .80mm (.031 in.) PBTP Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories Metric/in. Conversion Table 10.0 12.0 15.0 18.0 23.0 28.0 30.0 32.0 34.0 40.0 50.0 51.0 60.0 80.0 1.10 1.18 1.26 1.38 1.57 1.97 2.01 2.36 3.12 meter in.) Cable Assemblies Quick Disconnect Sensors This table converts millimeters inches reference illustrations included these pages Connector Connector Connector Connector 8000-5110 8000-5120 8000-5150 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED, Change last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount 10mm (.39 in.) Cable 9986-2000 Non-Flush Mount 15mm (.59 in.) Cable 9986-2200 9986-2065 9986-2265 Mounting Brackets Pages 114-115 9986-2100 9986-2165 9986-2300 9986 -2365 1.5V 500Hz 1.0mm (.039 in.) PBTP 1.5V 500Hz 1.0mm (.039 in.) PBTP 1.5V 300Hz 1.5mm (.059 in.) PBTP 1.5V 300Hz 1.5mm (.059 in.) PBTP Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cables purchased from Altech Fixed Cable Fixed Cable LOAD LOAD Normally Open Normally Open Connector Connector LOAD LOAD ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Normally Open Normally Open PREVIOUS WIRE SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-60V 400mA, LED's Operating Voltage Output Energized HOME FIND Higher Current Output Higher Voltage Range Carries mark (529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9982-4000 9982-4400 9982-4100 9982-4500 2.4V 2000Hz .20mm (.008 in.) PBTP Non-Flush Mount (.16 in.) Cable 9982-4200 9982-4600 9982-4300 9982-4700 2.4V 1000Hz .40mm (.016 in.) PBTP (.08 in.) 9982-4064 9982-4464 9982-4164 9982-4564 2.4V 2000Hz .20mm (.008 in.) PBTP 9982-4065 9982-4465 9982-4165 9982-4565 2.4V 2000Hz .20mm (.008 in.) PBTP 9984-4264 9982-4664 9982-4364 9982-4764 2.4V 1000Hz .40mm (.016 in.) PBTP 9982-4265 9982-4665 9982-4365 9982-4765 2.4V 1000Hz .40mm (.016 in.) PBTP Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. Style Connector 3-pin, Pico style, (.31 in.) supplied with Brass, Nickel Plated (BN) locknuts. PREVIOUS HOME FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table 12.0 18.0 .27.0 =1.06 29.0 35.0 45.0 50.0 60.0 80.0 1.14 1.37 1.77 1.97 2.36 3.15 This table converts millimeters inches reference illustrations included these pages Connector Connector Connector 8000-5220 PVC, Straight 8000-5230 PVC, Right Angle, 2LED, 8000-5240 PVC, Right Angle, 2LED, Flush Mount (.20 in.) Cable 9984-4000 9984-4400 9984-4100 9984-4500 2.4V 1000Hz .25mm (.01 in.) PBTP Non-Flush Mount (.31 in.) Cable 9984-4200 9984-4600 9984-4300 9984-4700 2.4V 500Hz .40mm (.016 in.) PBTP Connectors, Wire cable (PIN Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED, Connectors, Wire cable (PIN Connector 8000-5280 Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information 9984-4065 9984-4465 9984-4165 9984-4565 2.4V 1000Hz .25mm (.01 in.) PBTP 9984-4265 9984-4665 9984-4365 9984-4765 2.4V 500Hz .40mm (.016 in.) PBTP Mounting Brackets Pages 114-115 Wiring Diagrams Note: Wire colors applicable cables purchased from Altech Fixed Cable LOAD Fixed Cable LOAD Normally Open Normally Open Fixed Cable LOAD Fixed Cable LOAD Normally Closed Normally Closed Note: Sensor dimensions Connector LOAD Connector LOAD Normally Open Normally Open Connector LOAD Connector LOAD Normally Closed Normally Closed Connector Connector LOAD LOAD Normally Open Normally Open Connector LOAD Connector LOAD Normally Closed Normally Closed ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-60V 400mA LED's Operating Voltage Output Energized HOME FIND (529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Higher Current Output Higher Voltage Range Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9986-4000 9986-4400 9986-4100 9986-4500 10V-60V 2.4V Non-Flush Mount 15mm (.59 in.) Cable 9986-4200 9986-4600 9986-4300 9986-4700 2.4V .75mm (.030 in.) PBTB 10mm (.39 in.) 9986-4065 9986-4465 9986-4165 9986-4565 2.4V .50mm (.020 in.) PBTP 9986-4265 9986-4665 9986-4365 9986-4765 2.4V .75mm (.030 in.) PBTB Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material .50mm (.020 in.) PBTP Note: Sensor dimensions Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Connectors, Wire cable (PIN Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED, Connectors, 4PIN Wire cable (PIN Connectors 8000-5280 PVC, Right Angle HOME FIND Metric/in. Conversion Table 12.0 23.0 35.0 1.37 45.0 1.77 50.0 1.96 60.0 2.36 This table converts millimeters inches reference illustrations included these pages Change last digit connector number meter cable Refer pages 116-121 more cable information Mounting Brackets Pages 114-115 Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable LOAD Fixed Cable LOAD Normally Open Normally Open Fixed Cable LOAD Fixed Cable LOAD Normally Closed Normally Closed Connector Connector LOAD LOAD Normally Open Normally Open Connector LOAD Connector LOAD Normally Closed Normally Closed ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE STANDARD Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V Output Energized HOME FIND (529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Most complete range Fixed Cable Quick Disconnect Styles Available normally open (N.O.) normally closed (N.C.) output configuration Industry standard 10-30V operating voltage 200mA output current Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9961-0200 9961-4400 9961-0300 9961-4500 10V-30V 2.4V 2000 .15mm (.006 in.) PBTP 2.4V 2000 9961-0363 Non-Flush Mount (.08 in.) 9961-0265 9961-4465 9961-0365 9961-4565 2.4V 2000 1.5mm (.06 in.) 9961-0263 9961-0264 9961-4464 9961-0364 9961-4564 2.4V 2000 Cable 9961-0400 9961-4600 9961-0500 9961-4700 2.4V 2000 .20mm (.008in.) PBTB 9961-0463 9961-0464 9961-4664 9961-0465 9961-4665 9961-0565 9961-4765 2.4V 2000 .20mm (.008in.) PBTB Normally Open Normally Closed Normally Open Normally Closed 9961-0563 9961-0564 9961-4764 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 2.4V 2000 2.4V 2000 .15mm (.006 in.) .15mm (.006 in.) .15mm (.006in.) PBTP PBTP PBTP .20mm (.008in.) .20mm (.008in.) PBTB PBTB Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. PORT PORT Style Connector 3-pin, Pico style, (.31 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. Connector clear, offering 360° viewing. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5220 PVC, Straight Connector 8000-5230 PVC, Right Angle, 2LED, Connector 8000-5240 PVC, Right Angle, 2LED, 63/65 Connectors, Wire cable (PIN 63/65 Connector 8000-5110 PVC, Straight 63/65 Connector 8000-5120 PVC, Right Angle 63/65 Connector 8000-5150 PVC, Right Angle, 2LED, 63/65 Connector 8000-5160 PVC, Right Angle, 2LED, 63/65 Connectors, 4PIN Wire cable (PIN 63/65 Connectors 8000-5280 PVC, Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information Metric/in. Conversion Table 12.0 23.0 28.0 =1.10 29.0 34.0 35.0 40.0 43.0 50.0 60.0 1.14 1.34 1.37 1.57 1.69 1.47 2.36 This table converts millimeters inches reference illustrations included these pages Flush Mount (.08 in.) Cable 9962-4000 9962-4400 9962-4100 9962-4500 2.4V 2000 2.4V 2000 9962-4163 Non-Flush Mount (.16 in.) 9962-4065 9962-4465 9962-4165 9962-4565 2.4V 2000 9962-4063 9962-4064 9962-4464 9962-4164 9962-4564 2.4V 2000 Cable 9962-4200 9962-4600 9962-4300 9962-4700 2.4V 10µA 1000 9962-4263 9962-4264 9962-4664 9962-4265 9962-4665 9962-4365 9962-4765 2.4V 10µA 1000 Mounting Brackets Pages 114-115 Wiring Diagrams Note: Wire colors applicable cable purchased from Altech 9961-4363 9962-4364 9962-4764 2.4V 10µA 1000 2.4V 10µA 1000 Fixed Cable LOAD Fixed Cable LOAD Normally Open Normally Open Fixed Cable LOAD Fixed Cable .20mm (.008in.) .20mm (.008in.) .20mm (.008in.) .20mm (.008in.) PBTB PBTB PBTB PBTB .40mm (.016in.) .40mm (.016in.) .40mm (.016in.) .40mm (.016in.) PBTB PBTB PBTB PBTB LOAD Note: Sensor dimensions Normally Closed Normally Closed Connector LOAD Connector LOAD Normally Open Normally Open Connector LOAD Connector LOAD PORT PORT Normally Closed Normally Closed 63/65 Connector 63/65 Connector ©Altech LOAD LOAD Normally Open Normally Open Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 63/65 Connector LOAD Connector LOAD Normally Closed Normally Closed PREVIOUS WIRE STANDARD Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA, Output Energized HOME FIND IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Most complete range Fixed Cable Quick Disconnect Styles Available normally open (N.O.) normally closed (N.C.) output configuration Industry standard 10-30V operating voltage 200mA output current Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9964-4000 9964-4400 9964-4100 9964-4500 2.4V 1000 .25mm (.01 in.) PBTP 2.4V 1000 .25mm (.01 in.) PBTP 9964-4163 Non-Flush Mount (.31 in.) 9964-4065 9964-4465 9964-4165 9964-4565 2.4V 1000 (.20 in.) 9964-4063 Cable 9964-4200 9964-4600 9964-4300 9964-4700 2.4V .40mm (.016 in.) PBTB 9964-4263 9964-4265 9964-4665 Normally Open Normally Closed Normally Open Normally Closed 9964-4363 9964-4365 9964-4765 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 2.4V .40mm (.016 in.) PBTB 2.4V .40mm (.016 in.) PBTB .25mm (.01 in.) PBTP Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.The Connector clear, offering 360° viewing. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories Metric/in. Conversion Table 10.0 12.0 15.0 18.0 23.0 28.0 30.0 32.0 34.0 40.0 50.0 51.0 60.0 80.0 1.10 1.18 1.26 1.34 1.57 1.97 2.01 2.36 3.12 meter in.) Cable Assemblies Quick Disconnect Sensors This table converts millimeters inches reference illustrations included these pages 63/65 Connectors, Wire cable (PIN 63/65 Connector 8000-5110 PVC, Straight 63/65 Connector 8000-5120 PVC, Right Angle 63/65 Connector 8000-5150 PVC, Right Angle, 2LED, 63/65 Connector 8000-5160 PVC, Right Angle, 2LED, 63/65 Connectors, 4PIN Wire cable (PIN 63/65 Connectors 8000-5280 PVC, Right Angle Change last digit connector number meter cable Flush Mount 10mm (.39 in.) Cable 9966-4000 9966-4400 9966-4100 9966-4500 2.4V .50mm (.02 in.) PBTB 2.4V .50mm (.02 in.) PBTB 9966-4163 Non-Flush Mount 15mm (.59 in.) Cable 9966-4200 9966-4600 9966-4300 9966- 4700 2.4V 10µA .75mm (.03 in.) PBTB 2.4V 10µA .75mm (.03 in.) PBTB Refer pages 116-121 more cable information 9966-4063 9966-4263 9966-4265 9966-4665 9966-4365 9966-4765 2.4V 10µA .75mm (.03 in.) PBTB 9966-4065 9966-4465 9966-4165 9966-4565 2.4V .50mm (.02 in.) PBTB Mounting Brackets Pages 114-115 Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Note: Sensor dimensions Fixed Cable Fixed Cable LOAD LOAD Normally Open Normally Open Fixed Cable Fixed Cable LOAD LOAD Normally Closed Normally Closed 63/65 Connector 63/65 Connector LOAD LOAD Normally Open Normally Open 63/65 Connector LOAD 63/65 Connector LOAD ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Normally Closed Normally Closed PREVIOUS WIRE EXTENDED SENSING DISTANCE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized HOME FIND IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) times sensing distance over standard sensors Reduces accidental collisions Ideal applications where larger sensing distance required mounting space tight Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9981-4000 Non-Flush Mount (.12 in.) Cable 9981-4200 (.08 in.) 9981-4064 9981-4065 9981-4264 9981-4265 Normally Open Normally Closed Normally Open Normally Closed 9981-4100 9981-4164 9981-4165 9981-4300 9981-4364 9981-4365 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 10V-30V 2.4V 2000 .2mm (.008 in.) PBTP 2.4V 2000 .2mm (.008 in.) PBTP 2.4V 2000 .2mm (.008 in.) PBTP 2.4V 2000 .3mm (.012 in.) PBTB 2.4V 2000 .3mm (.012 in.) PBTB 2.4V 2000 .3mm (.012 in.) PBTB Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. Style Connector 3-pin, Pico style, (.31 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. 50/65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Non-Metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table 12.0 23.0 27.0 28.0 =1.06 =1.10 29.0 30.0 34.0 35.0 40.0 50.0 1.14 1.18 1.33 1.37 1.57 1.96 This table converts millimeters inches reference illustrations included these pages Connector Connector Connector 8000-5220 PVC, Straight 8000-5230 PVC, Right Angle, 2LED, 8000-5240 PVC, Right Angle, 2LED, PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED, 50/65 Connector 8000-5110 50/65 Connector 8000-5120 50/65 Connector 8000-5150 50/65 Connector 8000-5160 Flush Mount (.16 in.) Cable 9982-4900 Flush Mount (.31 in.) Cable 9984-4900 Change last digit connector number meter cable Refer pages 116-121 more cable information 9982-4950 9984-4950 Mounting Brackets Pages 114-115 12mA 2.4V 1500 .40mm (.016 in.) PBTB 2.4V 1500 .40mm (.016 in.) PBTB 2.4V 10µA .80mm (.03 in.) PBTB 2.4V 10µA .80mm (.03in.) PBTB Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Note: Sensor dimensions Fixed Cable LOAD Fixed Cable LOAD Normally Open Normally Open Connector LOAD Connector LOAD Normally Open Normally Open 50/65 Connector 50/65 Connector LOAD LOAD Normally Open Normally Open ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE EXTENDED SENSING DISTANCE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Ouput Energized HOME FIND (529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) times sensing distance over standard sensors Reduces accidental collisions Ideal applications where larger sensing distance required mounting space tight Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9966-3900 Metric/in. Conversion Table 30.0 50.0 60.0 80.0 1.20 1.47 2.36 3.12 15mm (.59 in.) 9966-3965 Normally Open Normally Closed Normally Open Normally Closed This table converts millimeters inches reference illustrations included these pages Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 10V-30V 2.4V 1.5mm (.06 in.) PBTP 2.4V 1.5mm (.06 in.) PBTP Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED, Change last digit connector number meter cable Refer pages 116-121 more cable information Mounting Brackets Pages 114-115 Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Fixed Cable LOAD Normally Open Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. Connector LOAD Normally Open ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE HIGH SPEED Brass, Nickel Plated (BN), Cylindrial,Threaded, 10-30V 200mA Output Energized HOME FIND (529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Metric/in. Conversion Table 40.0 45.0 50.0 65.0 1.57 1.77 1.96 2.55 Switching frequency 4000 Standard body length Carries mark Flush Mount Sensing Distance Cable Connector Style Cat.No. Cable 9962-2300 (.08 in.) 9962-2365 Normally Open This table converts millimeters inches reference illustrations included these pages Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 10V-30V 2.4V 4000 .20mm (.008 in.) PBTP 2.4V 4000 .20mm (.008 in.) PBTP Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED, Connector 8000-5160 PVC, Right Angle, 2LED, Change last digit connector number meter cable Refer pages 116-121 more cable information Mounting Brackets Pages 114-115 Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Fixed Cable LOAD Normally Open Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. Connector LOAD Normally Open ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE PLASTIC METAL HOUSING Brass, Nickel Plated (BN), Plastic (TROGAMID Cylindrical,Threaded, 10-30V 400mA Output Energized HOME FIND IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Metal plastic housings Higher output currents, 400mA Long body length Carries mark Flush Mount Sensing Distance Cable Connector Cat. Non-Flush Mount (.16 in.) Cable 9962-3300 9962-1600 Flush Mount (.20 in.) Cable 9964-3100 9964-1500 (.08 in.) Cable 9962-3100 9962-1400 Normally Open Normally Closed Normally Open Normally Closed 9962-3200 9962-1500 9962-3400 9962-1700 9964-3200 9964-1600 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material 10-30V 2.4V 2000Hz .20mm (.008 in.) PBTB Trogamid 10-30V 2.4V 2000Hz .20mm (.008 in.) PBTB Nickel Plated Brass 10-30V 2.4V 1000Hz .40mm (.016 in.) PBTB Trogamid 10-30V 2.4V 1000Hz .40mm (.016 in.) PBTB Nickel Plated Brass 10-30V 2.4V 1000Hz .5mm (.02 in.) PBTB Trogamid 10-30V 2.4V 10mA 1000Hz .5mm (.02 in.) PBTB Nickel Plated Brass Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with non-metallic locknuts Trogamid housings, Brass, Nickel Plated (BN) locknuts Nickel Plated Brass housings. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories Metric/in. Conversion Table 12.0 18.0 30.0 =1.20 34.0 38.0 40.0 42.0 50.0 60.0 1.31 1.50 1.57 1.65 1.97 2.36 This table converts millimeters inches reference illustrations included these pages Mounting Brackets Pages 114-115 Non-Flush Mount Flush Mount (.31 in.) Cable 9964-3300 9964-1700 9966-3100 Non-Flush Mount 15mm (.59 in.) Cable 9966-3300 9966-1300 10mm (.39 in.) Cable 9966-1100 9964-3400 9964-1800 9966-3200 9966-1200 9966-3400 9966-1400 10-30V 2.4V 10mA 500Hz .8mm (.03 in.) PBTB Trogamid 10-30V 2.4V 10mA 500Hz .8mm (.03 in.) PBTB Nickel Plated Brass 10-30V 2.4V 10mA 500Hz 1.0mm (.04 PBTB Trogamid 10-30V 2.4V 10mA 500Hz 1.0mm (.04 PBTB Nickel Plated Brass 10-30V 2.4V 10mA 300Hz 1.5mm (.06 PBTB Trogamid 10-30V 2.4V 10mA 300Hz 1.5mm (.06 PBTB Nickel Plated Brass Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable LOAD Fixed Cable LOAD Normally Open Normally Open ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE MINI METAL HOUSING Cylindrical, 10-30V 200mA Output Energized HOME FIND IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) 4mm, 5mm, 6.5mm diameter Economically Priced Non-connector models feature polyurethane (PUR) cables Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9980-1010 Flush Mount 0.8mm (0.03 in.) Cable 9980-2010 0.8mm (0.03 in.) 9980-1064 9980-2064 Normally Open Normally Closed Normally Open Normally Closed 9980-1110 9980-1164 9980-2110 9980-2164 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material 10V-30V 5000 Typ. 5000 Typ. .04mm (.003 in.) PBTP Nickel Plated Brass 5000 Typ. .04mm (.003in.) PBTB Nickel Plated Brass 5000 Typ. .04mm (.003in.) PBTB Nickel Plated Brass .04mm (.003 in.) PBTP Nickel Plated Brass Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts model. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Fixed Cable in.).Supplied with Brass, Nickel Plated (BN) locknuts model. PREVIOUS HOME FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table .019in. 19.0 20.0 23.0 25.0 35.0 40.0 43.0 1.37 1.57 1.69 This table converts millimeters inches reference illustrations included this catalog Connector Connector Connector 8000-5220 PVC, Straight 8000-5230 PVC, Right Angle, 2LED, 8000-5240 PVC, Right Angle, 2LED, Change last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount 1.5mm (0.06 in.) Cable 9961-1200 Non-Flush Mount 3.0mm (0.11 in.) Cable 9961-1300 9961-1264 9961-1364 Mounting Brackets Pages 114-115 2.4V 2000 .15mm (.006in.) PBTB Stainless Steel 2.4V 2000 .15mm (.006in.) PBTB Stainless Steel 2.4V 2000 .15mm (.006in.) PBTB Stainless Steel 2.4V 2000 .15mm (.006in.) PBTB Stainless Steel Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cabl;e purchased from Altech Fixed Cable LOAD Fixed Cable LOAD Normally Open Normally Open Connector Connector LOAD LOAD Normally Open Normally Open ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE COMPLEMENTARY OUTPUTS (N.O. N.C.) Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized HOME mark FIND Carries IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9962-6200 Non-Flush Mount (.16 in.) Cable 9962-6300 (.08 in.) 9962-6265 9962-6365 (Complementary NO/NC) (Complementary NO/NC) Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 10V-30V 2.4V 2000 2.4V 2000 .20mm (.008 in.) PBTP 2.4V 1000 .40mm (.016 in.) PBTB 2.4V 1000 .40mm (.016 in.) PBTB .20mm (.008 in.) PBTP Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. PREVIOUS HOME FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table 10.0 12.0 18.0 32.0 1.26 42.0 1.65 44.0 50.0 51.0 54.0 60.0 70.0 80.0 1.73 1.96 2.12 2.36 2.75 3.12 This table converts millimeters inches reference illustrations included these pages Connectors, 4PIN Wire cable (PIN Connectors 8000-5280 PVC, Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount in.) Cable 9964-6200 Non-Flush Mount (.31 in.) Cable 9964-6300 Mounting Brackets Pages 114-115 9964-6265 9964-6365 2.4V 1000 .5mm (.02 in.) PBTB 2.4V 1000 .5mm (.02 in.) PBTB 2.4V 10µA .8mm (.031 in.) PBTB 10µA .8mm (.031 in.) PBTB Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Cable Connector (N.O.) (N.C.) LOAD Connector BK(N.O.) LOAD (N.C.) LOAD ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE EXTENDED TEMPERATURE RANGE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized HOME FIND Temperature Range: 100°C (104 212°F) Carries mark IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9962-6010 Non-Flush Mount (.16 in.) Cable 9962-6110 (.08 in.) 9962-6065 9962-6165 Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 10V-30V 2.4V 2000 2.4V 2000 .20mm (.008 in.) PBTP 2.4V 1000 .40mm (.016 in.) PBTB 2.4V 1000 .40mm (.016 in.) PBTB .20mm (.008 in.) PBTP Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories Metric/in. Conversion Table 12.0 18.0 32.0 34.0 40.0 50.0 51.0 60.0 1.23 1.31 1.39 1.47 1.59 2.36 meter in.) Cable Assemblies Quick Disconnect Sensors This table converts millimeters inches reference illustrations included these pages Connector Connector Connector Connector 8000-5110 8000-5120 8000-5150 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED, Change last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount (.20 in.) Cable 9964-6010 Non-Flush Mount (.31 in.) Cable 9964-6110 9964-6065 9964-6165 Mounting Brackets Pages 114-115 2.4V 1000 .50mm (.02 in.) PBTB 2.4V 1000 .50mm (.02 in.) PBTB 2.4V 10µA .80mm (.03 in.) PBTB 2.4V 10µA .80mm (.03 in.) PBTB Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable LOAD Normally Open Connector LOAD ©Altech Normally Open Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized HOME FIND IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Circuitry that protects electro-magnetic interference Flush models have teflon ceramic coatings protect weld slag Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Non-Flush Mount (.16 in.) Cable 9962-5900 (.08 in.) Cable 9962-5840 9962-5845 9962-5965 Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material 10V-30V 2.4V 2.4V .20mm (.008 in.) Teflon Teflon Plated Brass 2.4V 15Hz .40mm (.016 in.) PBTB Nickel Plated Brass 2.4V .40mm (.016 in.) PBTB Nickel Plated Brass .20mm (.008 in.) Teflon Teflon Plated Brass Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. 45/65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories Metric/in. Conversion Table 10.0 12.0 50.0 52.0 60.0 70.0 80.0 1.47 2.04 2.36 2.75 3.12 meter in.) Cable Assemblies Quick Disconnect Sensors This table converts millimeters inches reference illustrations included these pages 45/65 Connector 8000-5110 45/65 Connector 8000-5120 45/65 Connector 8000-5150 45/65 Connector 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED, Change last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount (.20 in.) Cable 9964-5840 Non-Flush Mount (.31 in.) Cable 9964-5900 Mounting Brackets Pages 114-115 9964-5845 9964-5965 2.4V .50mm (.02 in.) Teflon Teflon Plated Brass 2.4V .50mm (.02 in.) Teflon Teflon Plated Brass 2.4V 10µA .80mm (.03 in.) PBTB Nickel Plated Brass 2.4V 10µA .80mm (.03 in.) PBTB Nickel Plated Brass Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable LOAD Normally Open Connector LOAD Normally Open ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized HOME FIND Circuitry that protects electro-magnetic interference Flush models have teflon ceramic coatings protect weld slag Carries mark IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Flush Mount Sensing Distance Cable Connector Style Cat. Non-Flush Mount 15mm (.59 in.) Cable 9966-5900 10mm (.39 in.) Cable 9966-5840 45/65 9966-5845 9966-5965 Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material 10V-30V 2.4V 2.4V 1.0mm (.039 in.) Teflon Teflon Plated Brass 2.4V 1.5mm (.059 in.) PBTB Nickel Plated Brass 2.4V 15Hz 1.5mm (.059 in.) PBTB Nickel Plated Brass 1.0mm (.039 in.) Teflon Teflon Plated Brass Note: Sensor dimensions Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. 45/65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS Metric/in. Conversion Table 10.0 12.0 30.0 =1.20 60.0 2.36 80.0 3.15 HOME FIND This table converts millimeters inches reference illustrations included these pages Accessories meter in.) Cable Assemblies Quick Disconnect Sensors 45/65 Connector 8000-5110 45/65 Connector 8000-5120 45/65 Connector 8000-5150 45/65 Connector 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, PVC, Right Angle, 2LED, Change last digit connector number meter cable Refer pages 116-121 more cable information Mounting Brackets Pages 114-115 Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable LOAD Normally Open Connector LOAD Normally Open ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS ANALOG SENSORS Cylindrical,Threaded Brass, Nickel Plated (BN), 18-30V Analog Output M12, M18, Digital Analog Output HOME FIND IEC(529) IP67 (NEMA Protection Short Circuit Protection Overload Protection Temperature Range: 70°C (-13 158°F) Output voltage proportional target distance Ideal determining position information Excellent linearity Shielded cable ouputs cable models Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Voltage Range Supply Current Max. Load Current Max. Switching Frequency Temperature Drift Repeatability Front Material Output Voltage Range Flush Mount (.04 in.) (.16 in.) Cable 9914-0900 ±0.3V PBTB 1-9V 0.5mm (.02 in.) 2.5mm (0.1 in.) Cable 9914-0800 18V-30V ±0.3V 9914-0865 ±0.3V PBTP 1-9V 9914-0965 ±0.3V PBTB 1-9V PBTP 1-9V Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS 10.0 12.0 18.0 30.0 HOME FIND Accessories Metric/in. Conversion Table =1.20 58.0 2.28 70.0 2.75 80.0 3.12 100.0mm 3.94 This table converts millimeters inches reference illustrations included these pages meter in.) Cable Assemblies Quick Disconnect Sensors Connectors, 4PIN Wire cable (PIN Connectors 8000-5280 PVC, Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information Non-Flush Mount (.28 in.) 14mm (.55 in.) Cable 9914-1000 ±0.3V PBTB 1-9V Digital Cable 9914-0500 ±0.3V PBTB 1-9V 9914-0565 ±0.3V PBTB 1-9V analog output voltage digitized 8100-2100 switching unit 8100-2400/2500 modules. (Separate Accessory items refer pages more information.) Mounting Brackets Pages 114-115 Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Note: Sensor dimensions Fixed Cable M12, M18, SHIELD WIRE LOAD Fixed Cable CONDUCTOR CABLE GREY DIG. OUTPUT SHIELD WIRE LOAD 65CN M12, M18, LOAD connected internally (Can used shield with shielded cable) ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS 3WIRE EXTENDED RANGE PLUS Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized HOME FIND times sensing distance IEC(529) IP67 (NEMA Protection Sensing ranges from (.12 in.) Ideal applications where large 40mm (1.57 in.) sensors will Short Circuit Protection Carries mark Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Flush Mount Sensing distance Cable Connector Style Cat. Cable 9981-5000 Non-Flush Mount (0.2 in.) 9981-5065 (0.1 in.) 9981-5064 Cable 9981-5200 9981-5264 9981-5265 Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Housing Material Repeatability 10-30V 20mA 200mA 2.4V 100µA 1000Hz Nickel Plated Brass .15mm (.005 in.) 10-30V 20mA 200mA 2.4V 100µA 1000Hz Nickel Plated Brass .15mm (.005 in.) 10-30V 20mA 200mA 2.4V 100µA 1000Hz Nickel Plated Brass .15mm (.005 in.) 10-30V 20mA 200mA 2.4V 100µA 500Hz Nickel Plated Brass .3mm (.01 in.) 10-30V 20mA 200mA 2.4V 100µA 500Hz Nickel Plated Brass .3mm (.01 in.) 10-30V 20mA 200mA 2.4V 100µA 500Hz Nickel Plated Brass .3mm (.01 in.) Fixed Cable in.). Supplied with Brass, Nickel Plated (BN) locknuts. Connector 3-pin, Pico style, (.31 in.) supplied with Brass, Nickel Plated (BN) locknuts. Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS 12.0 40.0 44.0 45.0 50.0 1.39 1.73 1.77 1.97 HOME 52.0 54.0 56.0 58.0 60.0 62.0mm 66.0 70.0 2.04 2.12 2.20 2.28 2.36 2.44 2.60 2.75 FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5220 PVC, Straight Connector 8000-5230 PVC, Right Angle, 2LED,PNP Connector 8000-5240 PVC, Right Anglr, LED, Connector 8000-5110 PVC, Straight Connector 8000-5120 PVC, Right Angle Connector 8000-5150 PVC, Right Angle, 2LED Connector 8000-5160 PVC, Right Angle, 2LED Metric/in. Conversion Table This table converts millimeters inches reference illustrations included these pages Flush Mount (0.2 in.) Cable 9982-5000 Non-Flush Mount 10mm (0.4 in.) Cable 9982-5200 Change last digit connector number meter cable Refer pages 116-121 more cable information Mounting Brackets Pages 114-115 9982-5065 9982-5265 Flush Installation Non-Flush Installation 10-30V 20mA 200mA 2.4V 100µA 800Hz Nickel Plated Brass .3mm (.01 in.) 10-30V 20mA 200mA 2.4V 100µA 800Hz Nickel Plated Brass .3mm (.01 in.) 10-30V 20mA 200mA 2.4V 100µA 400Hz Nickel Plated Brass .5mm (.02 in.) 10-30V 20mA 200mA 2.4V 100µA 400Hz Nickel Plated Brass .5mm (.02 in.) 0.2d General Mounting must maintain minimum distance between adjacent opposite sensors addition non-target metals specified drawings above. Flush mount sensors must extend least times sensor diameter above adjacent metal housing. Non-flush mount sensors must extend distance greater than sensing distance (Sn). Please contact Altech installation assistance Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Note: Sensor dimensions Fixed Cable LOAD Normally Open Connector LOAD Normally Open Connector LOAD Normally Open ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Metal Material PREVIOUS 3WIRE EXTENDED RANGE PLUS Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V 200mA Output Energized HOME FIND times sensing distance Ideal applications where large sensors will Carries mark IEC(529) IP67 (NEMA Protection Sensing ranges from (.12 in.) 40mm (1.57 in.) Short Circuit Protection Overload Protection Reverse Polarity Protection Wire Break Resistance Temperature Range: 70°C (-13 158°F) Flush Mount Sensing Distance Cable Connector Style Cat. Cable 9984-5000 Non-Flush Mount 20mm (0.8 in.) Cable 9984-5200 12mm (0.4 in.) 9984-5065 9984-5265 Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Housing Material Repeatability 10V-30V 2.4V Nickel Plated Brass 0.6mm (.02 in.) 2.4V Nickel Plated Brass 0.6mm (.02 in.) 2.4V Nickel Plated Brass (.04 in.) 2.4V Nickel Plated Brass (.04 in.) Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Fixed Cable in.). Supplied with Brass, Nickel Plated (BN) locknuts. PREVIOUS HOME FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table 12.0 40.0 44.0 45.0 50.0 1.57 1.73 1.77 1.97 52.0 54.0 56.0 58.0 60.0 62.0mm 66.0 70.0 2.04 2.12 2.20 2.28 2.36 2.44 2.60 2.75 This table converts millimeters inches reference illustrations included these pages Connector Connector Connector Connector 8000-5110 8000-5120 8000-5150 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED PVC, Right Angle, 2LED Change last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount 22mm (0.9 in.) Cable 9986-5000 Non-Flush Mount 40mm (1.57 in.) Cable 9986-5200 Mounting Brackets Pages 114-115 9986-5065 9986-5265 Flush Installation Non-Flush Installation 2.4V Nickel Plated Brass 1.1mm (.045 in.) 2.4V Nickel Plated Brass 1.1mm (.045 in.) 2.4V 100µA Nickel Plated Brass (.078 in.) 2.04V 100µA Nickel Plated Brass (.078 in.) 0.2d Metal Material General Mounting must maintain minimum distance between adjacent opposite sensors addition non-target metals specified drawings above. Flush mount sensors must extend least times sensor diameter above adjacent metal housing. Non-flush mount sensors must extend distance greater than sensing distance (Sn). Please contact Altech installation assistance Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable LOAD Normally Open Connector LOAD ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Normally Open PREVIOUS WIRE NAMUR Brass, Nickel Plated (BN), Plastic (TROGAMID-T) Cylindrical,Threaded HOME FIND energy device Operates hazardous areas with external amplifier Meets NAMUR regulations 19234 specifications Carries mark IEC(529) IP67 (NEMA Protection Reverse Polarity Protection Plastic Metal Housing according NAMUR Regulations 19234 Temperature Range: 70°C (-13 158°F) (For extended temperature models -40°C +125°C, consult Altech.) Flush Mount Sensing Distance Cable Connector Style Cat. Nickel Plated Brass (BN) Plastic (TROGAMID Ripple Voltage Voltage Range (supplied Pulsotronic 8100-2200 Unit) Output Current with target detection) Output Current target detection) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 8.2V 8.2V 2000 .1mm (.004 in.) PBTP (Metal Housing) Non-Flush Mount (.08 in.) Cable 9932-0200 9932-1600 8.2V 1000 .2mm (.008 in.) PBTP (Metal Housing) 8.2V (.04 in.) Cable 9932-0100 9932-0165 9932-0265 2000 1000 .2mm (.008 in.) PBTP (Metal Housing) .1mm (.004 in.) PBTP (Metal Housing) Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with non-metallic locknuts Brass, Nickel Plated (BN) locknuts through M30. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS 12.0 23.0mm HOME 24.0 25.0 28.0 30.0 40.0 50.0 1.16 1.20 1.57 1.97 FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table This table converts millimeters inches reference illustrations included these pages Connectors, Wire cable (PIN Connector 8000-5280 Right Angle Channge last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount (.08 in.) Cable 9932-0300 9932-1100 8.2V 8.2V 2000 .2mm (.008 in.) PBTP (Metal Housing) Non-Flush Mount (.16 in.) Cable 9932-0400 9932-1000 8.2V 1000 .4mm (.016 in.) PBTP (Metal Housing) 8.2V 1000 .4mm (.016 in.) PBTP (Metal Housing) Remote Amplifier 8100-2200, page 9932-0365 9932-0465 Mounting Brackets Pages 114-115 2000 .2mm (.008 in.) PBTP (Metal Housing) Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable Remote Amplifier Connector Remote Amplifier ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE NAMUR Brass, Nickel Plated (BN), Plastic (TROGAMID-T) Cylindrical,Threaded HOME FIND energy device Operates hazardous areas with external amplifier Meets NAMUR regulations 19234 specifications Carries mark IEC(529) IP67 (NEMA Protection Reverse Polarity Protection Plastic Metal Housing according NAMUR Regulations 19234 Temperature Range: 70°C (-13 158°F) Flush Mount Sensing Distance Cable Connector Style Cat. Nickel Plated Brass (BN) Plastic (TROGAMID Ripple Voltage Voltage Range (supplied Pulsotronic 8100-2200 Unit) Output Current with target detection) Output Current target detection) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Cable 9932-0500 9932-1300 8.2V 1000 8.2V 1000 .5mm (.02 in.) PBTP (Metal Housing) Non-Flush Mount (.31 in.) Cable 9932-0600 9932-1200 8.2V .8mm (.03 in.) PBTP (Metal Housing) 8.2V .8mm (.03 in.) PBTP (Metal Housing) (.20 in.) 9932-0565 9932-0665 .5mm (.02 in.) PBTP (Metal Housing) Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories Metric/in. Conversion Table 12.0 18.0 22.0 28.0 30.0 40.0 50.0 51.0 60.0 1.16 1.20 1.57 1.96 2.00 2.36 meter in.) Cable Assemblies Quick Disconnect Sensors This table converts millimeters inches reference illustrations included these pages Connectors, Wire cable (PIN Connector 8000-5280 Right Angle Change last digit connector number meter cable Refer page 116-121 more cable information Flush Mount 10mm (.39 in.) Cable 9932-0700 9932-1500 8.2V .1mm (.039 in.) PBTP (Metal Housing) 8.2V .1mm (.039 in.) PBTP (Metal Housing) Non-Flush Mount 15mm (.59 in.) Cable 9932-0800 9932-1400 8.2V 1.5mm (.059 in.) PBTP (Metal Housing) 8.2V 1.5mm (.059 in.) PBTP (Metal Housing) 9932-0765 9932-0865 Remote Amplifier 8100-2200, page Mounting Brackets Pages 114-115 Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable Remote Amplifier Connector Remote Amplifier ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE SENSORS Brass, Nickel Plated (BN), Cylindrical,Threaded, 5-30V 100mA M18, 10-55V Output Energized HOME FIND Wire devices reduce wiring requirements Economically Priced Carries mark IEC(529) IP67 (NEMA Protection Reverse Polarity Protection Temperature Range: 70°C (-13 158°F) Flush Mount Sensing distance Cable Connector Style Cat. Normally Open Normally Closed Non-Flush Mount (.16 in.) Cable 9962-5700 Flush Mount (0.2 in.) Cable 9964-5400 (.08 in.) Cable 9962-5600 9962-5665 9962-5765 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Material 5V-30V 100mA 0.5mA 500Hz .20mm (.008 in.) PBTP 5V-30V 100mA 0.5mA 500Hz .20mm (.008 in.) PBTP 5V-30V 100mA 0.5mA 500Hz .40mm (.016 in.) PBTP 5V-30V 100mA 0.5mA 500Hz .40mm (.016 in.) PBTP 10V-55V 200mA 6.5V 1.5mA 1000Hz .40mm (.016 in.) PBTP Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS 10.0 12.0 15.0 18.0 HOME 23.0 28.0 30.0 32.0 34.0 40.0 50.0 51.0 60.0 80.0 1.10 1.18 1.26 1.34 1.57 1.97 2.01 2.36 3.12 FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table This table converts millimeters inches reference illustrations included these pages Connector Connector 8000-5110 PVC, Straight 8000-5120 PVC, Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information Non-Flush Mount Flush Mount Non-Flush Mount (.31 in.) Cable 9964-5500 Mounting Brackets Pages 114-115 10mm (.39 in.) Cable 9966-5400 15mm (.59 in.) Cable 9966-5500 10V-55V 200mA 6.5V 1.5mA 500Hz .80mm (.03 in.) PBTP 10V-55V 200mA 6.5V 1.5mA 500Hz (.039 in.) PBTP 10V-55V 200mA 6.5V 1.5mA 300Hz 1.5mm (.059 in.) PBTP Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable LOAD Connector LOAD ©Altech Corp. Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE STANDARD SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 90-250V Output Energized HOME FIND (529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F) Most complete range Fixed Cable Quick Disconnect Styles Available normally open (N.O.) normally closed (N.C.) output configuration This series features 360° viewing connector type "67" Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current (20ms 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Cable 9952-0500 Non-Flush Mount (.16 in.) 9952-0568 (.08 in.) 9952-0562 66/67 9952-0566 9952-0567 Cable 9952-0400 9952-0462 66/67 9952-0466 9952-0467 9952-0468 9952-0900 9952-0966 9952-0967 9952-0968 9952-0800 9952-0866 9952-0867 9952-0868 90V-250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .2mm (.008in.) PBTP 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .2mm (.008in.) PBTP 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .2mm (.008in.) PBTP 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .2mm (.008in.) PBTP 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V 250V 50/60Hz 3mA/220V 250V 50/60Hz 3mA/220V 1.5mA/110V 1.5mA/110V 15Hz/220V 15Hz/220V .4mm (.016in.) .4mm (.0016in.) .4mm (.016in.) .4mm (.016in.) PBTB PBTB PBTB PBTB Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Style Connector 3-pin, Mini style, 25mm (1.0 in.) supplied with Brass, Nickel Plated (BN) locknuts. 66/67/68 Style Connectors 66/67 connectors 4-pin, connector, 3-pin), Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. Connector clear, offering 360° viewing. (66/68 (66/68 Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS 12.0 23.0 28.0 =1.10 HOME 29.0 34.0 35.0 40.0 43.0 50.0 60.0 1.14 1.34 1.37 1.57 1.69 1.47 2.36 FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5030 66/67 Connector 8000-5060 66/67 Connector 8000-5070 Connector 8000-5130 Connector 8000-5140 PVC, Straight PVC, Right Angle PVC, Straight Straight Right Angle Metric/in. Conversion Table This table converts millimeters inches reference illustrations included these pages Change last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount (0.2 in.) Cable 9954-2200 Non-Flush Mount (.31 in.) 9954-2268 Mounting Brackets Pages 114-115 9954-1968 9954-2262 66/67 9954-2266 9954-2267 Cable 9954-1900 9954-1962 66/67 9954-1966 9954-1967 9954-2600 9954-2666 9954-2667 9954-2668 9954-2500 9954-2568 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .8mm (.031in.) PBTB 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .8mm (.031in.) PBTB 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .8mm (.031in.) PBTB 250V 50/60Hz 3mA/220V 1.5mA/110V 15Hz/220V .8mm (.031in.) PBTB Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable Note: Sensor dimensions Fixed Cable LOAD Yellow/GRN LOAD Yellow/GRN Normally Open Normally Closed Connector LOAD Normally Open 66/67 Connector Yell/GRN 66/67 Connector Yell/GRN Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 LOAD LOAD Normally Open Normally Closed (66/68 (66/68 Connector Red/WHT LOAD Connector Red/WHT LOAD Normally Open Normally Closed PREVIOUS WIRE STANDARD SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 90-250V Output Energized HOME FIND (529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F) Most complete range Fixed Cable Quick Disconnect Styles Available normally open (N.O.) normally closed (N.C.) output configuration This series features 360° viewing connector type "67" Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Short Term Current (20ms 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Cable 9956-1500 10mm (.39 in.) 9956-1562 9956-1566 9956-1567 9956-1568 9956-1900 9956-1968 250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTP 250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTP 250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTP 250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTP 250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V (.039 in.) PBTB Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Style Connector 3-pin, Mini style, 25mm (1.0 in.) supplied with Brass, Nickel Plated (BN) locknuts. (66/68 66/67/68 Style Connectors 66/67 connectors 4-pin, connector, 3-pin), Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts Connector clear, offering 360° viewing. Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS 12.0 23.0 28.0 =1.10 HOME 29.0 34.0 35.0 40.0 43.0 50.0 60.0 1.14 1.34 1.37 1.57 1.69 1.97 2.36 FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Connector 8000-5030 66/67 Connector 8000-5060 66/67 Connector 8000-5070 Connector 8000-5130 Connector 8000-5140 PVC, Straight PVC, Right Angle PVC, Straight Straight Right Angle Metric/in. Conversion Table This table converts millimeters inches reference illustrations included these pages Change last digit connector number meter cable Refer pages 116-121 more cable information Non-Flush Mount 15mm (0.59 in.) Cable 9956-1400 Mounting Brackets Pages 114-115 9956-1467 9956-1462 9956-1466 9956-1468 9956-1800 9956-1868 250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V 1.5mm (.0596in.) PBTB 250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V 1.5mm (.059 in.) PBTB 250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V .4mm (.016in.) PBTB 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V .4mm (.016in.) PBTB 250V 50/60Hz 3A/220V 1.5mA/110V 15Hz/220V .5mm (.02in.) PBTB Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable Note: Sensor dimensions Fixed Cable LOAD Yellow/GRN LOAD Yellow/GRN Normally Open Normally Closed Connector LOAD Normally Open 66/67 Connector 66/67 Connector Yell/GRN Yell/GRN Connector Red/WHT LOAD ©Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 LOAD LOAD Normally Open (66/68 Normally Closed Connector Red/WHT LOAD Normally Open Normally Closed PREVIOUS WIRE EXTENDED VOLTAGE RANGE Brass, Nickel Plated (BN), TROGAMID Cylindrical,Threaded, 20-250V Output Energized HOME FIND (529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F) Higher Current Rating Wider Voltage Range Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material Cable 9924-0500 Non-Flush Mount (.16 in.) Cable 9924-0700 (.08 in.) Cable 9924-1100 9924-0568 Cable 9924-1000 9924-0768 9924-0400 9924-1300 9924-0468 9924-0900 9924-1200 9924-0968 20V-250V 50/60Hz 15Hz .20mm (.008 in.) PBTP Nickel Plated Brass 250V 50/60Hz 15Hz .20mm (.008 in.) PBTP Trogamid 250V 50/60Hz 15Hz .20mm (.008 in.) PBTP Nickel Plated Brass 250V 50/60Hz 15Hz .40mm (.016 in.) PBTB Nickel Plated Brass 250V 50/60Hz 15Hz .40mm (.016 in.) PBTB Trogamid 250V 50/60Hz 15Hz .40mm (.016 in.) PBTB Nickel Plated Brass Nickel Plated Brass Housings Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with non-metallic locknuts Trogamid housings Nickel Plated (BN) locknuts Nickel Plated Brass housings. Trogamid Housings Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Style Connectors 3-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. PREVIOUS HOME FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table 12.0 54.0 =2.12 60.0 64.0 70.0 80.0 2.36 2.52 2.75 3.15 This table converts millimeters inches reference illustrations included these pages Connector Connector 8000-5130 Straight 8000-5140 Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount (0.2 in.) Cable 9921-1200 Non-Flush Mount (0.3 in.) Cable 9921-1500 Mounting Brackets Pages 114-115 Cable 9921-2000 Cable 9921-2200 9921-1568 9921-1268 9921-1300 9921-2100 9921-1368 9921-1700 9921-2300 9921-1768 250V 50/60Hz 15Hz .50mm (.02 in.) PBTB Nickel Plated Brass 250V 50/60Hz 15Hz .50mm (.02 in.) PBTB Trogamid 250V 50/60Hz 15Hz .50mm (.02 in.) PBTB Nickel Plated Brass 250V 50/60Hz 15Hz .8mm (.039 in.) PBTB Nickel Plated Brass 250V 50/60Hz 15Hz .8mm (.039 in.) PBTB Trogamid 250V 50/60Hz 15Hz .8mm (.039 in.) PBTB Nickel Plated Brass Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable Note: Sensor dimensions Fixed Cable LOAD Yellow/GRN LOAD Yellow/GRN Normally Open Normally Closed Fixed Cable Fixed Cable LOAD LOAD Normally Open Normally Closed Connector Red/WHT Connector Red/WHT LOAD LOAD Normally Open Normally Closed Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE EXTENDED VOLTAGE RANGE Brass, Nickel Plated (BN), TROGAMID Cylindrical,Threaded, 20-250V Output Energized HOME FIND (529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F) Higher Current Rating Wider Voltage Range Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Normally Open Cable 9916-2600 10mm (0.39 in.) Cable 9916-2900 9916-2668 Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Material Housing Material 9916-2100 9916-2400 9916-2168 20V-250V 50/60Hz 15Hz (.039 in.) PBTP Nickel Plated Brass 250V 50/60Hz 15Hz (.039 in.) PBTP Trogamid 250V 50/60Hz 15Hz (.039 in.) PBTP Nickel Plated Brass Nickel Plated Brass Housings Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with non-metallic locknuts Trogamid housings Brass, Nickel Plated (BN) locknuts Nickel Plated Brass housings. Trogamid Housings Style Connectors 3-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table 12.0 30.0 38.0 48.0 =1.18 =1.50 =1.89 50.0 58.0 60.0 80.0 1.96 2.28 2.36 3.15 This table converts millimeters inches reference illustrations included these pages Connector Connector 8000-5130 Straight 8000-5140 Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information Non-Flush Mount 15mm (0.59 in.) Cable 9916-2700 Mounting Brackets Pages 114-115 Cable 9916-3000 9916-2768 9916-2300 9916-2500 9916-2368 250V 50/60Hz 15Hz 1.5mm (.059 in.) PBTB Nickel Plated Brass 250V 50/60Hz 15Hz 1.5mm (.059 in.) PBTB Trogamid 250V 50/60Hz 15Hz 1.5mm (.059 in.) PBTB Nickel Plated Brass Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Note: Sensor dimensions Fixed Cable Fixed Cable LOAD Yellow/GRN LOAD Yellow/GRN Normally Open Normally Closed Fixed Cable Fixed Cable LOAD LOAD Normally Open Normally Closed Connector Red/WHT Connector Red/WHT LOAD LOAD Normally Open Normally Closed Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS WIRE WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 20-250V 300mA/500mA Output Energized HOME FIND IEC(529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F) Circuitry that protects electro-magnetic interference Flush models have teflon ceramic coatings protect weld slag Carries mark Flush Mount Sensing Distance Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current 1Hz) Switching Frequency Resistance Load Hysterisis Temperature Drift Repeatability Front Material Housing Material 9952-5840 Non-Flush Mount (.16 in.) Cable 9952-5900 (.08 in.) Cable 9952-5848 9952-5968 9952-5640 9952-5648 9952-5700 9952-5768 20V-250V 50/60Hz 250V 50/60Hz .10mm (.004 in.) Teflon Teflon Plated Brass 250V 50/60Hz 15Hz .2mm (.008 in.) PBTB Nickel Plated Brass 250V 50/60Hz .2mm (.008 in.) PBTB Nickel Plated Brass .10mm (.004 in.) Teflon Teflon Plated Brass Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. 48/68 Style Connector 3-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 PREVIOUS HOME FIND Accessories meter in.) Cable Assemblies Quick Disconnect Sensors Metric/in. Conversion Table 10.0 12.0 18.0 60.0 70.0 80.0 =2.36 =2.75 =3.15 This table converts millimeters inches reference illustrations included these pages 48/68 Connector 8000-5130 PVC, Straight 48/68 Connector 8000-5140 Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information Flush Mount (.20 in.) Cable 9954-5840 Non-Flush Mount (.31 in.) Mounting Brackets Pages 114-115 9954-5968 9954-5848 Cable 9954-5900 9954-5640 9954-5648 9954-5700 9954-5768 250V 50/60Hz .25mm (.01 in.) Teflon Teflon Plated Brass 250V 50/60Hz .25mm (.01 in.) Teflon Teflon Plated Brass 250V 50/60Hz .4mm (.016 in.) PBTB Nickel Plated Brass 250V 50/60Hz .4mm (.016 in.) PBTB Nickel Plated Brass Note: Sensor dimensions Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable LOAD Yellow/GRN Normally Open 48/68 Connector Red/WHT LOAD Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Normally Open PREVIOUS WIRE WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 20-250V 300/500mA Output Energized HOME FIND Circuitry that protects electro-magnetic interference Flush models have teflon ceramic coatings protect weld slag Carries mark IEC(529) IP67 (NEMA Protection Temperature Range: 70°C (-13 158°F) Flush Mount Sensing Distance Cable Connector Style Cat. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current 1Hz) Switching Frequency Resistance Load Hysterisis Temperature Drift Repeatability Front Material Housing Material 9956-5840 Non-Flush Mount 15mm (.59 in.) Cable 9956-5900 10mm (.39 in.) Cable 9956-5848 9956-5968 9956-5640 9956-5648 9956-5700 9956-5768 20V-250V 50/60Hz .5mm (.02 in.) Teflon Teflon Plated Brass 250V 50/60Hz .5mm (.02 in.) Teflon Teflon Plated Brass 250V 50/60Hz .75mm (.03 in.) PBTB Nickel Plated Brass 250V 50/60Hz 15Hz .75mm (.03 in.) PBTB Nickel Plated Brass Note: Sensor dimensions Fixed Cable (6ft. 6in.). in.) cable length, change last digits part number other cable lengths and/or cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 48/68 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. PREVIOUS Metric/in. Conversion Table 10.0 12.0 30.0 80.0 =1.18 =3.15 HOME FIND This table converts millimeters inches reference illustrations included these pages Accessories meter in.) Cable Assemblies Quick Disconnect Sensors 48/68 Connector 8000-5130 PVC, Straight 48/68 Connector 8000-5140 Right Angle Change last digit connector number meter cable Refer pages 116-121 more cable information Mounting Brackets Pages 114-115 Wiring Diagrams Note: Wire colors applicable cable purchased from Altech Fixed Cable LOAD Yellow/GRN Normally Open 48/68 Connector Red/WHT LOAD Normally Open Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908) 806-9400 (908) 806-9490 Other recent searchesQ85VR3DLB - Q85VR3DLB Q85VR3DLB Datasheet PS21963-T - PS21963-T PS21963-T Datasheet MN103S5405YD - MN103S5405YD MN103S5405YD Datasheet ML9059 - ML9059 ML9059 Datasheet IDT74FST163213 - IDT74FST163213 IDT74FST163213 Datasheet IB0016 - IB0016 IB0016 Datasheet DG485 - DG485 DG485 Datasheet ADRF6601 - ADRF6601 ADRF6601 Datasheet
Privacy Policy | Disclaimer |