| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Performance Data Interrupting Capacity: Endurance: Overload Cycli
Top Searches for this datasheetSERIES Performance Data Interrupting Capacity: Endurance: Overload Cycling: Dielectric Strength: Insulation Resistance: Voltage Drop: Vibration: Shock: Acceleration: Weight: Exceeds Protection Current Ratings Amperes 3,000 amps 28V, 2,500 amps 115V, 120V, Hz.: inductive load-2,500 cycles; resistive load-5,000 cycles; 30V, inductive load-1,000 cycles; resistive load-5,000 cycles; mechanical cycling, load-5,000 cycles operations 200% rated current rated voltage 1,500V, minimum less than megohms 500V, volt maximum rated current Exceeds MIL. STD. 202, Method 204, Condition Exceeds g's, Millisec (half-sine pulse) STD. 202, Method Test grams (0.286 lbs.) Single-Pole High Performance Protection Very High Current Rated Circuits: Protects circuits from amperes Meets Mounting Dimensions: mounting dimensions compatible with Military Standard Drawing requirements 25017 MIL-C5809 Heavy-Duty Components: Extra heavy contacts wide sturdy terminals Trouble-Free Contact Life: Contacts mounted spring-loaded pivots maintain high-contact pressure improve quenching capability 170-001 fills need compact, reliable breaker protect circuits high range through amperes. only unit this range that mounting dimensions compatible with Military Standard Drawing MS25017. Designed protect heavy-duty aircraft electrical systems, breaker features separate overload mechanical latches. unit's trip-free design prevents from being held closed manually against overload that would ordinarily cause open. breaker used either circuits. series only heavy-duty aircrafttype circuit breaker available ampere range. Overload Calibration Data Specification Table Must Hold Must Trip 200% Overload 400% Overload 600% Overload Hour Within Hour Seconds Seconds Seconds 25°C +71°C -40°C Test Time Parameters Trip curve available consult factory Dimensions Ordering Information Ampere Rating Mechanical Products, Inc. 1824 River Street P.O. Jackson, 49204 (517) 782-0391 (517) 782-2810 Voltage Drop Max.* .100 .100 .100 .100 .100 .100 Part Number 170-001-125 170-001-140 170-001-150 170-001-160 170-001-180 170-001-200 rated nominal current. other ratings, consult factory. ©Copyright 1995, Mechanical Products, Inc. Rights Reserved. SERIES PERCENTAGE CURCUIT BREAKER'S RATED CURRENT Protection Current Ratings Amperes 170-001 fills need compact, reliable breaker protect circuits high range through amperes. only unit this range that mounting dimensions compatible with Military Standard Drawing MS25017 MIL-C-5809. TIME OPEN (TRIP) SECONDS Overload Calibration Data Specification Table Must Hold Must Trip 200% Overload 400% Overload 600% Overload Hour Within Hour Seconds Seconds Seconds 25°C +71°C -40°C Test Time Parameters Mechanical Products, Inc. 1824 River Street, P.O. 729, Jackson, 49204 (517) 782-0391, (517) 782-2810 SERIES Dimensions Mechanical Products, Inc. 1824 River Street, P.O. 729, Jackson, 49204 (517) 782-0391, (517) 782-2810 ©Copyright 1995, Mechanical Products, Inc. Rights Reserved. Other recent searchesXAP16b - XAP16b XAP16b Datasheet MMDT5551 - MMDT5551 MMDT5551 Datasheet KPED-3820SURC - KPED-3820SURC KPED-3820SURC Datasheet HCT35 - HCT35 HCT35 Datasheet CMS-S060-040 - CMS-S060-040 CMS-S060-040 Datasheet BCP68 - BCP68 BCP68 Datasheet 74AUP1G158 - 74AUP1G158 74AUP1G158 Datasheet 2N5872 - 2N5872 2N5872 Datasheet
Privacy Policy | Disclaimer |