| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Performance Data Interrupting Capacity: Endurance: Overload Cycli
Top Searches for this datasheetSERIES 1536 Performance Data Interrupting Capacity: Endurance: Overload Cycling: Dielectric Strength: Insulation Resistance: Voltage Drop: Vibration: Shock: Acceleration: Weight: 1,500V, minimum Exceeds grams (.29 lbs.) Miniature Protection Ambient-Temperature Compensated 1,000 amps 205V, Hz., phase symmetrical fault. 1,000 amps 120V, Hz., single phase fault 120VAC, Hz.: inductive load-5,000 cycles; resistive load-5,000 cycles; mechanical cycling, load-5,000 cycles operations 200% load less than megohms 500V, Varies with rating. (see "Ordering Information") Exceeds MIL. STD. 202, Method 204, Condition Exceeds g's, Millisec (half-sine pulse) STD. 202, Method Test 3-Pole High Performance Three-Phase Protection: Features common trip mechanism which simultaneously trips three phases regardless which phase overloaded Integral Barriers: Terminals separated barriers molded into case Single-Hole Mounting: quick, easy installation Shock Vibration Resistant Construction: Permits portable, mobile, types airborne equipment 1536-001 lightweight, miniature breaker that features three bimetal sensing elements having very fast electro-dynamic response under short circuit conditions, standard trip characteristics lower levels overloads. common trip mechanism assures simultaneous trip three phases, regardless which phase overloaded. Single hole mounting small size facilitate easy installation. breaker's one-piece, glass-filled case features integrally-molded barriers separate terminals. Overload Calibration Data Specification Table Must Hold Must Trip 200% Overload 400% Overload 600% Overload 10.00 2.00 1.00 Balanced* 70.0 10.0 MAX. Hour Within Hour Seconds Seconds Seconds Seconds 25°C +71°C -54°C Test Time Parameters 1000% Overload 0.35 *Unbalanced load, individual phases: 145% Trip curve available consult factory Dimensions Ordering Information Ampere Rating Mechanical Products, Inc. 1824 River Street P.O. Jackson, 49204 (517) 782-0391 (517) 782-2810 Voltage Drop Max.* 0.350 0.325 0.300 0.250 0.200 0.180 1.180 0.175 0.175 0.150 Part Number 1536-001-5 1536-001-705 1536-001-10 1536-001-15 1536-001-20 1536-001-25 1536-001-30 1536-001-35 1536-001-40 1536-001-50 rated nominal current. other ratings, consult factory. ©Copyright 1995, Mechanical Products, Inc. Rights Reserved. SERIES 1536 PERCENTAGE CURCUIT BREAKER'S RATED CURRENT Miniature Protection Ambient-Temperature Compensated 1536-001 lightweight, circuit breaker that features three bimetal sensing elements having very fast electro-dynamic response under short circuit conditions, standard trip characteristics lower levels overloads. common trip mechanism assures simultaneous trip three phases, regardless which phase overloaded. TIME OPEN (TRIP) SECONDS Overload Calibration Data Specification Table Must Hold Must Trip 200% Overload 400% Overload 600% Overload 1000% Overload 10.00 2.00 1.00 0.35 70.0 10.0 Hour Within Hour Seconds Seconds Seconds Seconds 25°C +71°C -54°C Test Time Parameters Mechanical Products, Inc. 1824 River Street, P.O. 729, Jackson, 49204 (517) 782-0391, (517) 782-2810 SERIES 1536 Dimensions Mechanical Products, Inc. 1824 River Street, P.O. 729, Jackson, 49204 (517) 782-0391, (517) 782-2810 ©Copyright 1995, Mechanical Products, Inc. Rights Reserved. Other recent searchesSA001Z17B - SA001Z17B SA001Z17B Datasheet PC1060 - PC1060 PC1060 Datasheet NJU6433 - NJU6433 NJU6433 Datasheet FLI2301 - FLI2301 FLI2301 Datasheet CH-2074 - CH-2074 CH-2074 Datasheet AM2520YD02 - AM2520YD02 AM2520YD02 Datasheet 2SC5295G - 2SC5295G 2SC5295G Datasheet
Privacy Policy | Disclaimer |