The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

ACA5-20PC Series E156931 Order on-line www.datel.com Fe


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet




ACA5-20PC Series
E156931
Order on-line www.datel.com
Features
Scales displays output 50:5A 2000:5A current transformers ranges (0-50 0-2000 Amp) options, power options, models Functionally complete: On-board current transformers Scaling/interface circuitry Precision converters Bright displays Subminiature, 1.38" 0.88" package Easy-to-read, 0.37"/9.4mm digits powered models: 120Vac 400Hz, 120/220Vac 50/60Hz models "self-powered" +5-40V powered model 2000V isolation; UL/CSA recognized Digital replacements analog ammeters
Input LED-Display 50-2000A Ammeters
ACA5-20PC Series Ammeters designed scale digitally display output standard, 5A-output current transformers (50:5A, 500:5A, 1000:5A, etc.). Simply pass secondary/output wires "primary" through ACA5-20PC's on-board apply power meter, you're instantly measuring currents over ranges from 0-50A (with 100mA resolution) 0-2000A (with resolution). Because they accept outputs from previously installed high-current CT's, ACA5-20PC's instantly bring modern digital precision older ammeters. functionally complete ACA5-20PC ammeters incorporate scaling/interface circuitry mate on-board precision digit) converter. A/D's output directly drives meters' large (0.37"/9.4mm digit height), easy-to-read, displays. models employ auto-zero circuits, precision bandgap references, super stable metal-film resistors unsurpassed accuracy (±0.15%FS) stability. ACA5-20PC meters either (120/220Vac 50/60Hz 120Vac 400Hz) (+5-40V) powered. models powered same supply whose current they monitoring. ACA5-20PC's provide 2000Vdc isolation between measured current their power supply, models UL/CSA recognized. Each meter housed subminiature, 1.38" 0.88", epoxy-encapsulated package whose behind-the-panel installation depth inches. Each meter supplied with plastic bezel assembly with sealing gaskets (DATEL DMS-BZL4).
Figure ACA5-20PC Series Simplified Schematic
DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E-mail: sales@datel.com Internet: www.datel.com
ACA5-20PC Series
Performance/Functional Specifications Typical 25°C, unless otherwise noted. Full-Scale Current (45-450Hz) Min. Models Overcurrent Rating Performance Sampling Rate Accuracy Measurement Type Temperature Drift +60°C) Zero-Current Reading Power Supply Voltage ACA5-20PC-X-AC1-RL ACA5-20PC-X-AC2-RL ACA5-20PC-X-DC1-RL Power Supply Current ACA5-20PC-X-AC1-RL ACA5-20PC-X-AC2-RL ACA5-20PC-X-DC1-RL Power Supply Terminal Block Wire Size Type Insulation Strip Length Screw Tightening Torque Display Display Type Size Overrange Indication Display Reading/Decimal Point Physical/Environmental Operating Temperature Storage Temperature Humidity (non-condensing) Case Material Dimensions Weight (all models) +4.75 -001 Typ.
Order on-line www.datel.com
Max. Units Amps
Ordering Information
rated full-scale current samples second ±0.15%FS counts Sine wave input, full-wave averaging, calibrated ±0.2 ±0.4 Counts/°C Counts Vac@47-99Hz Vac@350-450Hz mA@47-99Hz mA@350-450Hz mAdc
ACA5 20PC
Input Range: (45-450Hz) 50.0A 75.0A 100.0A 150.0A 199.9A 250A 300A 400A 500A 600A 750A 1000A 1500A 1999A No.* 39-3681401* 39-3681402* 39-3681403* 39-3681404* 39-3681405* 39-3681406* 39-3681407* 39-3681408* 39-3681409* 39-3681410* 39-3681411* 39-3681412* 39-3681413* 39-3681414* Color: Standard
Dielectric Withstanding Voltage 2000
Power Supply: 85-264Vac@50/60Hz 85-140Vac@400Hz +5-40Vdc
Accessories: DMS-20-CP Panel cutout punch
DMS-BZL4 bezel assembly with sealing gasket supplied with each ammeter. Matching Current Transformers: current transformers ACA5-20PC ammeters available from DATEL nominal cost. pricing technical information, visit www.datel.com, select Digital Panel Meters, then Accessories.
16-22AWG (solid stranded) 0.25 inches pound-inches (0.4Nm) digit LED, 0.37"/9.4mm digit height Model dependent. Ordering Info. Polycarbonate 1.38"W 0.88"H Depth model dependent (see Mechanical Specifications) ounces grams)
Technical Notes IMPORTANT! ensure safe reliable operation, ACA5-20PC ammeters must installed serviced qualified technical personnel. Contact DATEL there doubt regarding ammeter installation and/or operation. Measurement Type: ACA5-20PC ammeters employ full-waverectified, average responding, rms-calibrated circuit measure stepped-down output their built-in current transformer (CT) Stated accuracy specifications measured using sine-wave current close full-scale input level, nominal line frequency. Calibration: Periodic recalibration ACA5-20PC ammeters required under normal, indoor operating environments. user calibration necessary, should performed qualified technical personnel. Calibration performed with potentially lethal voltages applied ACA5-20PC associated wiring, with specified full-scale current flowing through ammeter's built-in current transformer. plastic, fully-insulated adjusting tool must used access recessed calibration potentiometer located back meter (see Mechanical Specifications). Contact DATEL additional information required regarding calibration, setup, other technical issue pertaining ACA5-20PC ammeters. Wire Gauges Fusing: Wires specified Functional Specifications section must used making connections ACA520PC Series ammeters. power-supply load wiring must rated supply voltages currents they will conduct must comply with code application-mandated requirements pertaining user's specific installation.
specified Full-Scale Current current carried single wire passing through center hole ACA5-20PC's on-board load current ultimately being measured. Overcurrent Rating continuous rating that applies Full-Scale Current. does apply circuitry external meter. Listed accuracy specifications apply over range Rated Full-Scale Current over frequencies 45-450Hz. Maximum reverse polarity protection "DC1" models -40Vdc. specified maximum power supply currents steady-state. AC-powered models draw larger surges initial turn
DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356
E-mail: sales@datel.com Internet: www.datel.com
ACA5-20PC Series
supply wires connected both meter load must fused according current rating wire gauge being used, accordance with applicable regulatory codes. Also, wire insulation should stripped within +/-10% stated dimensions, wires should inserted into such that their insulation pinched screw terminal. used only powering meter's internal circuitry. must used supply current external loads. AC-powered models draw minimal steady-state supply currents (50mA max.), most applications, they fused according supply wire's maximum amperage rating. However, these models draw significantly higher surge currents brief periods when line voltage initially applied. Supply Polarity Grounding: supply inputs, TB1-A TB1-B, ac-powered ACA5-20PC ammeters themselves polarity sensitive, that they have internal designations. Also, ac-powered ACA5-20PC ammeters include require connection earth/chassis ground. Connector Torque Ratings: important tighten TB1's, screwterminals their rated torque specification pound-inches (0.4Nm). Proper tightening will minimize connector losses ensure safe, reliable operation. DC-Powered Models: DC-powered models draw minimal supply currents most applications fused according supply wire's maximum amperage rating. However, sure check comply with applicable codes regulations ensure proper installation operation. Isolation: on-board (L1) provides minimum 2000Vdc isolation Panel Installation connections ACA5-20PC Series ammeters must made after ammeter securely attached panel with load supply voltages de-energized (off). Care should exercised when passing conductors through ammeter's built-in installed wire positions should such that minimal forces applied built-in TB1, ammeter itself. high-vibration environments, proper strain reliefs used load supply wiring. ensure secure panel-mount installation, DATEL recommends
Step
between current-carrying conductor passing through primary circuit ammeter supply voltage connected TB1. This isolation rating only applies applications which load wiring (i.e., wire passing through L1's center hole) does connect directly indirectly TB1-A TB1-B. Precautions: normal operation, current transformer's secondary circuit operates very voltage closed-loop operation burden resistance. However, still generate potentially lethal voltages output current suddenly interrupted. example, loose secondary connections cause condition referred "inductive kick". Inductive kick generate extremely high voltages across intermitent secondary connections. Therefore, implementing connections current transformer's output leads must only performed with zero load-current, that with power applied load circuit. Connections Grounding: Some applications require connecting external CT's output leads earth/chassis ground. USA, consult latest revision National Electrical Code (NEC) more information regarding grounding. After mechanical assembly completed, connect output leads external each other after they through L1's center hole. Pressure-style connectors (commonly refered "wire nuts") acceptable long they rated number conductors voltage invloved. Replacing Analog Panel Meters: ACA5-20PC ammeters used direct replacements analog panel meters driven CT's. wiring operations must performed with both load supply power sources completely de-energized.
using DMS-BZL4 bezel assembly (with sealing gasket) supplied with each ammeter. Mechanical Specifications detailed cutout ammeter dimensions. Following four-step sequence shown Figure -being careful apply excessive force twisting motions-insert ammeter into panel opening. When using DMS-BZL4, install sealing gasket positioned between ammeter's front flange panel front surface (see Mechanical Specifications). sure securely tighten four screws supplied with bezel assembly.
Step Step
Step
Figure Panel Installation
DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E-mail: sales@datel.com Internet: www.datel.com
ACA5-20PC Series
Typical Wiring Diagrams
First pass carefully dress output wire from external through on-board (L1). Then connect supply shown. required, verify that correct line-power polarities applied external load (see Technical Note Ensure wires stripped terminals torqued correctly. proper operation, pass only single wire through on-board CT's center hole.
Figure ACA5-20PC AC-Powered Models
First pass carefully dress output wire from external through on-board (L1). Then connect powersupply wires TB1, observing correct positive ("+") negative ("-") polarities. Ensure wires stripped terminals torqued correctly. proper operation, pass only single wire through on-board CT's center hole.
5-40Vdc
Figure ACA5-20PC DC-Powered Models
DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E-mail: sales@datel.com Internet: www.datel.com
ACA5-20PC Series
Mechanical Specifications
Mechanical Dimensions: Inches (mm) Tolerances: ±0.02 (±0.51), ±0.010 (±0.254)
9001
REGISTERED DS-0446C 5/2003
DATEL, Inc. Cabot Boulevard, Mansfield, 02048-1151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com Email: sales@datel.com
DATEL (UK) LTD. Tadley, England Tel: (01256)-880444 DATEL S.A.R.L. Montigny Bretonneux, France Tel: 01-34-60-01-01 DATEL GmbH Germany Tel: 89-544334-0 DATEL Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-354-2025
DATEL makes representation that products circuits described herein, other technical information contained herein, will infringe upon existing future patent rights. descriptions contained herein imply granting licenses make, use, sell equipment constructed accordance therewith. Specifications subject change without notice. DATEL logo registered DATEL, Inc. trademark.

Other recent searches


SMR-2560-45C - SMR-2560-45C   SMR-2560-45C Datasheet
SBC81822VG - SBC81822VG   SBC81822VG Datasheet
SV865570-WF - SV865570-WF   SV865570-WF Datasheet
2003 - 2003   2003 Datasheet
PI6C3614-1 - PI6C3614-1   PI6C3614-1 Datasheet
MRF21125 - MRF21125   MRF21125 Datasheet
Mod5272 - Mod5272   Mod5272 Datasheet
5282 - 5282   5282 Datasheet
MBRV7030CTL - MBRV7030CTL   MBRV7030CTL Datasheet
MBRB2035CT - MBRB2035CT   MBRB2035CT Datasheet
MBRB2060CT - MBRB2060CT   MBRB2060CT Datasheet
MBRB1535CT - MBRB1535CT   MBRB1535CT Datasheet
MBRB1560CT - MBRB1560CT   MBRB1560CT Datasheet
HY5PS12421C - HY5PS12421C   HY5PS12421C Datasheet
HY5PS12821C - HY5PS12821C   HY5PS12821C Datasheet
HY5PS121621C - HY5PS121621C   HY5PS121621C Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive