| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
2001 Technical datasheet Converters series DC/DC MODULE
Top Searches for this datasheetALCATEL 2001 Technical datasheet Converters series DC/DC MODULE Single Output Watts Regulated Input Range Input Range series APPLICATIONS Distributed power systems Telecommunication equipment Industrial equipment Transportation equipment Process control equipment Battery powered systems FEATURES High efficiency High reliability Industry standard pin-out inch package Open frame product input voltage range Input reverse voltage protection Fixed frequency operation Operating temperature: -25°C +85°C: derating External output voltage adjustment Basic isolation system (input output) Approved 60950 1950 Output current limitation DESCRIPTION series high performance DC/DC converters supplies Watts output power inch package. These generation DC/DC converters equipped with self synchronous rectification offer very high efficiency, output, allowing operation over complete temperature range without derating. series offers wide input voltage range from 72VDC with telecommunication industrial standard outputs 12V, 3.3V 2.5V, open frame format. OPTIONS External synchronisaton: External output voltage adjustment: Trim Remote On/Off: Please order either option) part number structure type: SELECTION INPUT OUTPUT Model (VDC) Range (VDC) (VDC) Ripple Noise (p/p Max) Regulation Line load Typical Efficiency 36-72 36-72 36-72 36-72 19-72 19-72 19-72 2.5* ±0.05V ±0.05V ±0.05V ±0.05V ±0.05V ±0.05V ±0.05V ±0.1V ±0.1V ±0.1V ±0.1V ±0.1V ±0.1V ±0.1V part number structure, refers product package size: 0.5" Alcatel Converters July 2001 Specifications subject change without notice. Alcatel Converters accepts responsibility consequences arising from printing errors inaccuracies. DC/DC MODULE series SPECIFICATION Input voltage range: (48V nominal) (48V nominal) Input filter type: inductive Nominal current: 0.25A output version Reverse polarity protection: external fuse 0.5" 25.4 12.7mm) weight: Pin: CONNECTIONS FUNCTIONS INPUT PHYSICAL connected Vin(+) Vin(-) Synchronisation (optional) Remote On/Off Vout(+) Trim Vout(-) Storage temperature: OUTPUT Vout accuracy: full load out: selection guide Regulation: selection guide Current limitation: Inom Inom Static regulation: +1.5% Dynamic regulation: +0.1V Ripple noise: 50mV (20MHz Maximum power: External output trim: +5%, -10% Vnom Over Voltage Protection: Vout -40°C +110°C Operating temperature: -25°C +85°C (contact Lead temperature (soldering): +300°C (10s) Immunity: 1000-4-3, 1000-4-4 Emission: 55022 Class with external capacitance SAFETY MTBF HDBK Compliant with 60950 1950 million hours 45°C amb. temp. Bottom view Note: pins when option present, there pin. PACKAGE (15.24) (2.54) (7.62) (25.4) (5.08) (7.62) (2.54) Bottom view (20.32) (15.24) (2.54) (10.16) pins (10.16) TECHNICAL NOTES Floating Outputs These converters fully isolated. Designers connect either Vout(+) ground Vout(-) ground without damage. Filtering Noise reduction critical applications, input and/or output noise reduced installing external capacitors. Designers should always electrolytic capacitor tantalum capacitor located close possible converter. (50.8) Side view 0.49 (12.5) (5.08) dimensions Inches (Millimeters). Tolerance dimensions 0.01inch 0.25mm). mother card diameters 1.1mm 0.05mm. series START-UP Test Configuration REMOTE ON/OFF Turn Turn achieved using Remote On/Off pin. when Remote open, connected (+). Remote connected Vin(-), converter off. Remote ouptut therefore current should driven into Remote Input power source Power Module Load Differential probe Oscilloscope Typical performance output version Output Voltage 48V, <3.5V 0.6V Input Voltage CAPACITIVE LOAD series limit maximum capacitance connected output. converter operate current limit mode during start-up, affecting output ramp-up start-up time. optimum performance maximum value 100µF/A load recommended. best performance, capacitors should connected load. Max: 321mA Output Voltage Typical performance output version Output Voltage 48V, SYNCHRONISATION specifying using synchronisation option, converter synchronised with additional converters applying external signal shown below. voltage reference this circuit input Vin(-) pin. decoupling capacitors value between external clock converter 1nF. synchronisation signal compatible with value +1.2V, with maximum duty cycle 50%. series used without external synchronisation. this case Synchronisation left unconnected. converter then operates using internal oscilator. External Clock Input Voltage Max: 247mA Output Voltage Typical performance 3.3V output version Output Voltage 48V, Input Voltage Power Module Vout Max: 233mA Output Voltage Power Module Vout Alcatel Converters July 2001 Specifications subject change without notice. Alcatel Converters accepts responsibility consequences arising from printing errors inaccuracies. DC/DC MODULE series EFFICIENCY LINE LOAD OUTPUT VOLTAGE POINT ADJUSTMENT (TRIM) Output voltage trim allows user adjust output voltage point converter. This done connecting external resistor between Trim either Output(+) Output(-) pins. With external resistor connected between Trim Output pins, output voltage point (Vo, adj) reduced. (See page Typical performance output version Efficiency 3.3V 2.5V Vout Vout Vout Vout 12.4 12.45 47.5 6.82 12.72 Vout Vout 1.33 10.89 Parameter Vinput 0,25 0,75 Output Current Vout 10.89 Vout 1307 1028 Typical performance output version Efficiency Trim Trim Down Trimpot Parameter Vinput Output voltage trimming Output Current Typical performance 3.3V output version Efficiency STATIC REGULATION Typical performance output version Output voltage Typical performance 3.3V output version Output Voltage Parameter Vinput 36V, Output Current Output Current Output Current series DYNAMIC REGULATION With capacitive load Regulation test Input power source Power Module load CURRENT LIMIT provide protection fault condition (output overload), unit equipped with internal current limitation circuitry endure current limiting unlimited time. point current limit inception, unit shifts from voltage control current control. output voltage very reduced during severe fault, current limit circuit either fold back hiccup (output current decrease increase). unit operates normally once output current brought back specified range. Current probe Oscilloscope Amplifier Typical performance output version IOUT 0.1A/0.6A IOUT 0.5A/1A 0.6A 0.1A Iout Iout 0.5A Vout Vout Max: 78.9mV Min: 84.2mV Max: +21.2mV Min: -20.5mV Typical performance output version Load transients (with 100µF 100nF load) IOUT 0.2A/1A IOUT 1A/2A PARALLELING REDUNDANCY figure below shows redundancy achieved (n+1). diodes isolating converters should power Schottky diodes minimise power. Provision these diodes allows failed converter isolate itself from (n+1) group, without affecting converter operation. +Vin Power Module +Vout 0.2A Iout Iout Vout Vout Max: 29.9mV Min: 33.3mV Max: +38.9mV Min: 44.6mV Typical performance 3.3V output version Load transients (with 100µF 100nF load) IOUT 0.3A 1.8A 1.8A IOUT 1.5A -Vin Iout 1.5A Load Iout 0.3A Power Module Vout Vout -Vout Max: +34.2mV Min: 34.8mV Max: +33.2mV Min: 36.7mV Alcatel Converters July 2001 Specifications subject change without notice. Alcatel Converters accepts responsibility consequences arising from printing errors inaccuracies. DC/DC MODULE series OUTPUT RIPPLE NOISE Output ripple measured peak peak voltage with additional filter series with probe. SPECIFICATIONS Conducted noise: 55022 Standard Class. converter mounted double sided printed circuit board (PCB) with ground plane during measurements. fundamental switching frequency 250KHz. Electrical conditions: 48V, Iout Inom, C=100µF Input power source Power Module Filter Probe Receiver Pulse limiter load LISN C=100µF Coaxial cable Input power source Power Module Load LISN Oscilloscope Input Vout 0.33 Probe Typical performance output version Positive line 10dB/div Peak 10dB/div Negative line -Vout Measurements output version Start 30MHz Stop 150KHz Start 30MHz Stop 150KHz ripple: 26.2mV Typical performance output version IOUT (Resistive load) Positive line 10dB/div Peak 10dB/div Peak Vout 10mV/div Negative line 2µs/div Measurements 3.3V output version VIN= Start 150KHz Stop 30MHz Start: 150KHz Stop: 30MHz ripple: 43.4mV Typical performance 3.3V output version IOUT (Resistive load) Positive line 10dB/div Peak 10dB/div Peak Vout 10mV/div Negative line 1µs/div Start 150KHz Stop 30MHz Start 150KHz Stop 30MHz series RADIATED Peak DESIGNED CONSIDERATIONS Safety safety agency approval system which unit used, converter must installed compliance with spacing separation requirements safety agency standard, i.e. 1950, 22.2.950 60950. converter output considered meeting requirements safety extra voltage (SELV), following must true: outputs SELV floating with input also floating. inputs SELV grounded with output also grounded. SELV input must provided with reinforced insulation from other hazardous voltages including mains must have SELV reliability test performed combination with converters. Inputs must meet SELV requirements. input meets extra voltage (ELV) requirements, then converter's output considered ELV. input these units provided with maximum normal blow fuse Vin(+) lead. Input Output impedance source impedance both power feed load impedance will interact with converter's impedance. ratio between must possible i.e. characteristic impedance both input output. units have been designed completely stable without need external capacitors input output when configured with inductance input output circuits. Performance some applications enhanced addition external capacitance. distribution input voltage source converter contains significant inductance, addition 220-470 capacitor across input converter will help insure stability. capacitor required when powering module from impedance source with short, inductance, input power leads. Electromagnetic Fields: Radiated measured according test methods 55022 Class. Receiver Antenna Power Module Filters Load Input power source FARADAY CAGE Typical performance output version 10dB Peak Start 30MHz Stop 230MHz Typical performance output version 10dB Start 30MHz Stop 230MHz Typical performance 3.3V output version 10dB/div Class Peak ALCATEL CONVERTERS 2001 Technical datasheet ALCATEL CONVERTERS 78141 CEDEX FRANCE alcatel.converters@alcatel.fr 07/2001 Start 30KHz Stop 230MHz www.alcatel.com/converters Other recent searchesUC3584DW - UC3584DW UC3584DW Datasheet RTX-230 - RTX-230 RTX-230 Datasheet RTV-230 - RTV-230 RTV-230 Datasheet GPL130A - GPL130A GPL130A Datasheet DIP12-1A72-12L - DIP12-1A72-12L DIP12-1A72-12L Datasheet AN1669 - AN1669 AN1669 Datasheet MC44603 - MC44603 MC44603 Datasheet
Privacy Policy | Disclaimer |