| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
FEATURES/BENEFITS Random zero-cross models available applications zero
Top Searches for this datasheetOutput 125A, High Industrial Performance (HIPpak) Solid-State Relays FEATURES/BENEFITS Random zero-cross models available applications zero-cross turn-on voltage Input output protection control standard IP20 touch-proof flaps Connectors power wiring heat sinks available Designed conformity with EN60947-4-3 (IEC947-4-3) EN60950/VDE0805 (Reinforced Insulation) IP20 touch-proof flaps Series Part SH24D25 SH24A25 SH24D35 SH24A35 SH24D50 SH24R50 SH24R75 SH24D75 SH24D95 SH24D125 SH48R35 SH48D35 SH48A35 SH48R50 SH48D50 SH48A50 SH48R75 SH48D75 SH48A75 SH48R95 SH48D95 SH48A95 SH48R125 SH48D125 SH48A125 SH60D50 SH60D75 SH60D95 SH60D125 Load Voltage 12-275 12-275 12-275 12-275 12-275 12-275 12-275 12-275 12-275 12-275 24-510 24-510 24-510 24-510 24-510 24-510 24-510 24-510 24-510 24-510 24-510 24-510 24-510 24-510 24-510 24-690 24-690 24-690 24-690 Load Current 125A 125A 125A 125A 125A Control Voltage 3-32 20-265 Vac/dc 3-32 20-265 Vac/dc 3-32 3-32 3-32 3-32 3-32 3-32 3.5-32 3.5-32 20-265 Vac/dc 3.5-32 3.5-32 20-265 Vac/dc 3.5-32 3.5-32 20-265 Vac/dc 3.5-32 3.5-32 20-265 Vac/dc 3.5-32 3.5-32 20-265 Vac/dc 3.5-32 3.5-32 3.5-32 3.5-32 Switch Type Zero Cross Zero Cross Zero Cross Zero Cross Zero Cross Random Random Zero Cross Zero Cross Zero Cross Random Zero Cross Zero Cross Random Zero Cross Zero Cross Random Zero Cross Zero Cross Random Zero Cross Zero Cross Random Zero Cross Zero Cross Zero Cross Zero Cross Zero Cross Zero Cross TYPICAL APPLICATION Figure SHXXDXX relays Figure SHXXAXX relays Figure SHXXRXX relays 2005 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com Page SH\022005\Q1 Output 125A, High Industrial Performance (HIPpak) Solid-State Relays ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) INPUT (CONTROL) SPECIFICATIONS Series CONTROL CHARACTERISTICS Input Current Range SHXXR/D (except SH60) SHXXA SH60 Must Turn-Off Voltage SHXXR/D SHXXA Reverse Voltage Protection (R/D) Clamping Voltage (R/D) Input Immunity (EN61000-4-4) Input Immunity (EN61000-4-5) Units Figure SH24R/D, SH48R/D relays MECHANICAL SPECIFICATION Figure SH24A, SH48A relays Figure Figure SH60D relays Page SPECIFICATIONS SUBJECT CHANGE WITHOUT NOTICE 2005 TELEDYNE RELAYS SH\022005\Q1 Output 125A, High Industrial Performance (HIPpak) Solid-State Relays ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) OUTPUT (LOAD) SPECIFICATIONS Peak Voltage (VDR Clamping) SH24 SH48 SH60 Load Currrent Range (Resistive) output current output current output current output current output current output current .005 .005 .005 .005 .005 .005 Arms Arms Arms Arms Arms Arms (450) (950) 1200 1600 Vpeak Vpeak Vpeak Units Turn-On Time SHXXR SHXXD SHXXA Turn-Off Time SHXXR/D SHXXA Off-State dv/dt Maximum di/dt (Non-Repetitive) Operating Frequency SHXXR SHXXD/A fuse matching (<10ms) output current output current output current output current output current output current Junction-Case Thermal Resistance output current output current output current output current output current output current Conducted Immunity Level IEC/EN61000-4-4 (bursts) SH24 SH48/SH60 IEC/EN61000-4-5 (surge) SH24 SH48 SH60 criterion criterion criterion (with external VDR) criterion criterion 0.45 0.25 °C/W °C/W °C/W °C/W °C/W °C/W 1250 2500 7200 14400 24000 24.9 V/µs A/µs 0.04 24.9 Series Maximum Surge Current Rating (Non-Repetitive) output current output current output current output current output current output current On-State Voltage Drop Output Power Dissipation (Max) output current output current output current output current output current output current 0.9x0.9xI 0.016xI2 0.9x0.9xI 0.015xI2 0.9x0.9xI 0.012xI2 0.9x0.9xI 0.0045xI2 0.9x0.9xI 0.0035xI2 0.9x0.9xI 0.002xI2 1200 1700 2200 Zero-Cross Window (Typical) SHXXR SHXXD/A Off-State Leakage Current SHXXR SHXXD/A 2005 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com Page SH\022005\Q1 Output 125A, High Industrial Performance (HIPpak) Solid-State Relays SURGE CURRENT Series GENERAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) ENVIRONMENTAL SPECIFICATIONS Operating Temperature output current Units Above output current Storage Temperature Figure output current output current Above output current Ambient Humidity +125 +125 Vrms Vrms Input-Output Isolation Output-Case Isolation Insulation Resistance @500Vdc 4000 4000 1000 4000 IP20 Figure output current Rated Impulse Voltage Protection Level (CEI529) Vibration (10-55 according CE168) Shock (according CD168) Housing Material Baseplate 30/50 Figure output current UL94VO Aluminum, nickel-plated Figure output current Figure output current Figure 125A output current Page SPECIFICATIONS SUBJECT CHANGE WITHOUT NOTICE 2005 TELEDYNE RELAYS SH\022005\Q1 Output 125A, High Industrial Performance (HIPpak) Solid-State Relays THERMAL CURVES Series Figure output power Figure output power Figure output power Figure output power Figure output power Figure 125A output power 12°C/W corresponds relay without heat sink 6°C/W corresponds relay mounted DIN-rail adaptor (Teledyne DL12) 2005 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com Page SH\022005\Q1 Output 125A, High Industrial Performance (HIPpak) Solid-State Relays OPTIONAL CONNECTIONS Series Directly with wires, with without ferrules With tips (ring terminals) CONTROL WIRING Number Wires With special adaptation high-voltage relays Solid ferrule) Fine Stranded (with ferrule) Solid ferrule) Fine Stranded (with ferrule) Screwdriver Type Recommended Torque Pozidriv AWG18.AWG14 AWG18.AWG14 AWG18.AWG14 AWG18.AWG14 POWER WIRING Number Wires Solid ferrule) Fine Stranded (with ferrule) Solid ferrule) Fine Stranded (with ferrule) Screwdriver Type Recommended Torque AWG16.AWG8 AWG16.AWG10 AWG16.AWG8 AWG16.AWG10 Pozidriv Power with tips AWG6 16mm2 Options Fastons: Call AWG4 16mm2 13mm Special high current AWG2 35mm2 AWG0 50mm2 AWG0 50mm2 high current Page SPECIFICATIONS SUBJECT CHANGE WITHOUT NOTICE 2005 TELEDYNE RELAYS SH\022005\Q1 Output 125A, High Industrial Performance (HIPpak) Solid-State Relays Series 2-2.5°C/W Teledyne FW151 1.1°C/W Teledyne FW108 0.3°C/W Teledyne FW031 Mounting HIPpak SSRs must mounted heat sinks. large range heat sinks available. heat-sink mounting, thermal grease thermal with high conductibility specified Teledyne. Rail Adapter Teledyne DL12 Thermal Teledyne Typical Loads (Random) relays with random turn-on designed high inductive loads phase angle control applications. data sheet lists nominal current power thyristors corresponding resistive load (AC-51). Depending loads, check inrush current turn possible overvoltages turn OFF. Main applications: AC-55b Incandescent infrared lamps. Inrush current generally times during 10ms. Random relays often inphase angle controllers soft-starters with right control. AC-53 Three-phase motors. random turn-on relays drive such motors. AC-56a Transformer loads. Very high inrush current times random turn-on like table below lists recommended current values proper lifetime expectancy. Model 125A AC-53 Current (motor) 2.5A AC-55b Current (lamp) 2.5A AC-55b Current (transformer) 0.4A AC-55b Current (capacitor) Typical Loads (Zero-Cross) relays with zero-cross turn-on designed most types loads. data sheet lists AC-51 current value corresponding resistive loads. other loads, check inrush current turn possible overvoltages turn OFF: AC-55b Incandescent lamps. Inrush current generally times during 10ms. AC-55a Electric discharge lamp. These loads often have overcurrent turn overvoltage turn OFF, 400VAC 230VAC mains. AC-58 One-pole motors. These loads often have overcurrent turn overvoltage turn OFF, 400VAC 230VAC mains adapt current starting current motor. AC-53 Three-phase motors. zero-cross relays drive these motors, generally E3P/E3PT other threephase relays random range. AC-56a Transformer loads. Very high inrush current times random relay peak control SSR. AC-56b Capacitor loads with very high current turn overvoltage turn OFF. high-voltage relays well adapted high inrush current. 2005 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com Page SH\022005\Q1 Output 125A, High Industrial Performance (HIPpak) Solid-State Relays Protection protect against short-circuit load, fuse with value value specified. Immunity: data sheets list immunity level SSRs according main standards these products: IEC/EN61000-4-4 IEC/EN61000-4-5. compare high immunity level with other products market. Emission: Teledyne SSRs designed compliance with standards class equipment (Industry). this product domestic environments cause radio interference. this case user required employ additional devices reduce noise. SSRs complex devices that must interconnected with other equipment (loads, cables, etc.) form system. Because other equipment interconnections under Teledyne's control, shall responsability system integrator ensure that systems containing SSRs comply with requirement rules regulations applicable system level. phase angle applications, filter adapted load must necessary. very zero-cross voltage relays (<12V) improves conducted emission level comparison with most other SSRs market with zero-cross voltages often higher than 50V. Series Page SPECIFICATIONS SUBJECT CHANGE WITHOUT NOTICE 2005 TELEDYNE RELAYS SH\022005\Q1 Other recent searchesSP40001 - SP40001 SP40001 Datasheet NJM3404A - NJM3404A NJM3404A Datasheet KM718V949 - KM718V949 KM718V949 Datasheet ICS2101 - ICS2101 ICS2101 Datasheet GR-1221 - GR-1221 GR-1221 Datasheet 2SC4511 - 2SC4511 2SC4511 Datasheet
Privacy Policy | Disclaimer |