| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
CAPTEUR PROXIMITE MAGNETIQUE MAGNETIC PROXIMITY SENSOR Capteur am
Top Searches for this datasheetP/SEC/PTIC11220/B/11/06/2003 CAPTEUR PROXIMITE MAGNETIQUE MAGNETIC PROXIMITY SENSOR Capteur ampoule REED contact inverseur 100V 8VA/W 3VA/W MAGNETIC PROXIMITY SENSOR with REED switch changeover contact (form 100VApeak 8VA/W 3VA/W Marron/ brown Noir/black Bleu/ Blue page F/GB PTIC11220 plastique Plastic housing Dimensions cable rond round cable 0,15 fils bare wire untinned 31,2 23,7 autres longueurs demande/ other lengths request APPLICATIONS TYPIQUES TYPICAL APPLICATIONS directe Interrupteur courses Capteurs Standard detection Proximity sensors Limit switch Flow sensor travers d'une paroi Exemple capot machine aluminium plastique Detection across ferromagnetic part Example protection hood made plastic aluminium (plastique, aluminium, magnetic part (plastic, aluminium,.) d'une acier) champ paroi Detection ferromagnetic part Short circuit magnetic field Ferromagnetic part Proud serve technical caracteristics subject change without previous notice. sujettes modifications sans celduc P/SEC/PTIC11220/B/11/06/2003 20°C) specifications 20°C) Parameter Symbol ELECTRIQUE /ELECTRICAL Tension d'emploi /Rated operational voltage Puissance commutable power load Courant d'emploi Rated operational current DC-12 commande charges ohmiques charges statiques photocoupleur automate control resistive loads solid state loads (DC-12) with optical isolation p.l.c inputs) Autres charges: Respecter Limiter courant charges capacitives surtensions charges inductives Other loads must respected. Inrush current capacitive loads overvoltages inductive loads must limited/ Courant d'emploi minimal /minimum operational current Courant Leakage current Consommation hors charge supply current with load Chute tension drop voltage Tension isolement Rated insulation voltage Tension tenue chocs/ Rated impulse withstand voltage commutation frequency Fonction commutation Functional switch Life time (DC-12 20mA) GENERALES/ MECHANICAL ENVIRONMENTAL Code protection pollution/ Degree pollution d'utilisation operating temperature Tenue vibrations/ Vibration resistance Tenue chocs /Shocks resistance MAGNETIQUES MAGNETIC operating distances /Reproductibility Course /hysteresis BOITIERS RACCORDEMENT HOUSING WIRING housing wires page F/GB Typ. 0,1-100 0,4A 0,25A 0,25 Unit Vpeak VA/W 0,01V @0,1A class IEC60536 2500 changeover IP67 /IEC/EN60947-5-1 10gn (10-150hz) 600608-2-6 30gn (11ms) /IEC 60067-2-7 voir <10% voir plastic Distances /assured operating distance Aimant magnet hysteresis PT508000 PT516000 Nous consulter consult Nous consulter consult 31,2 23,7 Sensible champs principe Sensible Magnetic Field celduc www.celduc.com B.P. 42290 SORBIERS FRANCE E-Mail celduc-relais@celduc.com Service Commercial France Sales Dept.For Europe Tel. Sales Dept. Asia Other recent searchesSCM-2LH - SCM-2LH SCM-2LH Datasheet RO2045 - RO2045 RO2045 Datasheet NTR4501N - NTR4501N NTR4501N Datasheet NP34N055SLE - NP34N055SLE NP34N055SLE Datasheet HSMS-285x - HSMS-285x HSMS-285x Datasheet DMN3052L - DMN3052L DMN3052L Datasheet 2SD1614 - 2SD1614 2SD1614 Datasheet
Privacy Policy | Disclaimer |