The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Accessories factory field mounted V-EA miniature circuit breakers moto


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



V-EA Circuit Breaker Accessories
Accessories factory field mounted V-EA miniature circuit breakers motor protection switches enhanced control monitoring capabilities. Field mounting kits include necessary parts instructions. Accessories gang mounted single breaker (the Auxiliary Switch outside position). mounting arrangement links internal latchpins tripping mechanisms, ensuring simultaneous trips. Handles linked simplify manual resetting.
Type/ Cat. FA12U FA24U FA48U FA110Ua FA110Ua FA110Ua
Shunt Trip
Trip/Coil Voltage AC/DC 48-72V 110V 220V 380VAC Max. Coil Current Approvals 1.3A 0.6A 0.2A 0.25A 0.5A 0.8A
Undervoltage Trip
Type/ Cat. UA120 UA208 UA240 UA277 UA415 UA480 Line Voltage 60Hz* 120VAC 208VAC 240VAC 277VAC 415VAC 480VAC
Std.Pk.: Unit Weight: grams (0.27 lb.) Width: 17.5mm (.689in.)
Std.Pk.: Unit Weight: grams (0.16 lb.) Width: 17.5mm (.689in.)
Coil actuated, Shunt Trip allows electrical remote tripping breaker. trip-free housing terminal specifications same V-EA miniature circuit breakers.The Shunt Trip contains contacts which break tripping power circuit when tripped. available with trip-coils most standard control voltages. device listed general use.
Re-power your system under controlled conditions following power loss serious undervoltage. Altech/Sursum Undervoltage Trips coupled tripping latch pins V-EA which they attached, reliably producing trips drop-out voltage preventing resetting when less than line voltage present. Undervoltage Trip provided with least 6-inch pigtails stranded fixture wire hookup V-EA line terminals. Reset-Hold Voltage 0.85 Drop-Out Voltage 0.35
aOne device with wide voltage range.
Please consult Altech your 50Hz application needs.
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908)806-9400 (908)806-9490 www.altechcorp.com
Auxiliary Switch
Type/ Cat. H11U HFI11
Lock-out
Cat. EASS Prevent inadvertent resetting V-EA during maintenance. Fits 1/4" lock.
Ring Tongue Terminals
Available VE-A series. Please specify when ordering refer type designation.
Approvals
With: V-EA,
Std. Pk.: Unit Weight: grams (0.12 lb.) Width: (.354in.) Contact Ratings H11U HFI11 220V 230V 110V pulsed 220V pulsed 220V pulsed Wire Size (max.) 4mm2 AWG)
4mm2 AWG)
isolated, feedthrough Form contacts provided: with same form breaker designation, closed auxiliary contacts when breaker breaker contacts closed); with opposite form breaker designation, closed auxiliary contacts when breaker tripped breaker contacts open). Upper level terminals metalstamped "HS" lower level terminals stamped "HO", providing clear identification drawings physical wiring (line/load either terminal). Altech/Sursum Auxiliary Switch suitable logic interrogation two-circuit Form contact. also function auxiliary switch control circuits. H11U listed general use.
Busbar Systems
Please pgs. 32-35 your busbar needs.
Cooling Spacer
Cat. 15.960 also Correction Curve,
V-EA also locked position simply using
common lead meter seal, which gets through hole handle corresponding hole case housing.
Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908)806-9400 (908)806-9490 www.altechcorp.com

Other recent searches


SN74ACT08 - SN74ACT08   SN74ACT08 Datasheet
SN54ACT08 - SN54ACT08   SN54ACT08 Datasheet
NJU7600 - NJU7600   NJU7600 Datasheet
NJU7600M - NJU7600M   NJU7600M Datasheet
MICROSMD175F - MICROSMD175F   MICROSMD175F Datasheet
MC33789 - MC33789   MC33789 Datasheet
FSA2270T - FSA2270T   FSA2270T Datasheet
CM2835 - CM2835   CM2835 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive