| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Multifunction Time Delay Relay Plug-In Panel Mounting Five timing
Top Searches for this datasheetCNM5 series Multifunction Time Delay Relay Plug-In Panel Mounting Five timing functions selectable rotary switch sec. 9,990 timing range Fixed input type (120VAC 15%) output relay with DPDT contacts 1/16 style enclosure with 11-pin plug-in base Thumbwheel switches programming delay time File E22575 File LR15734 Timing Functions following page complete description timing functions. Initial Dielectric Strength Between Output Poles: 1,500V rms, Between Input Output: 1,500V rms, 60Hz. Timing Specifications Timing Ranges: 99.9 sec.; 99.9 min.; 99.9 9,990 Timing Adjustment: Digital adjustment thumbwheel switches. Tolerance: ±0.05% 0.04 sec.* Repeatability (Including first cycle operation.): ±0.05% 0.04 sec.* Reset Time (power interruption): typ.; max. Minimum Pulse Width, Control: Timing synchronized with input voltage frequency. Accuracy dependent input voltage frequency. Tolerance shows maximum variation from utility companies. Input Data 25°C Voltage: 120VAC 15%, Power Requirement: 120VAC. Transient Protection: Joule MOV. Input Voltage Limits Nominal Voltage 120VAC Minimum Voltage 102VAC Maximum Voltage 138VAC Environmental Data Temperature Range: Storage: -40°C +85°C. Operating: -10°C +55°C. Humidity: relative humidity, non-condensing. Contact Data 25°C Arrangement: Form (DPDT). Material: Silver-cadmium oxide alloy. Rating: 30VDC 277VAC, resistive; 250VAC; 120VAC. Expected Mechanical Life: million operations. Expected Electrical Life: 100,000 operations, min., rated load. Mechanical Data Termination: 11-pin octal style plug. Enclosure: Black plastic 1/16 (48mm 48mm) case. Sockets: Fits either 27E123 27E892 (snap-on) screw terminal sockets. Weight: (122g) approximate. Ordering Information -The following items normally maintained stock immediate delivery. Time Delay Relay Input Voltage 120VAC Part Number CNM5 Accessory Part Number SSA-24C667 Name Mounting Clip Description Ratchet-fit clip slides onto CNM5 from behind secure CNM5 panel mount applications. Outline Dimensions 1.88 (8.1) 2.83 (71.9) Mounting Clip Dimensions SSA-24C667 Mounting Clip 1.88 1.76 (44.7) 2.283 1.970 (58.0) (50.0) 2.047 (52.0) .560 (14.2) 3.15 (80.0) (16.3) Fits 1.77 1.77 panel cutout. Wiring Diagrams (Bottom Views) (pins numbered clockwise from keyway) EXTERNAL CONTROL SWITCH** CONTROL .591 (15.0) 1.654 (42.0) 1.890 (48.0) Optional Solid State Input Interface INPUT INPUT **Important: circuit switch recommended. "dry circuit" switch rated reliably switch currents less than 50mA. switch rated other than circuit result failure time delay relay function properly. Timer Function Descriptions Repeat: Output relay turned programmed time interval which started application input power. Relay stays equal time interval, then turns cycle repeated free-running basis with equal times until terminated removal input power. flashing when output relay continuously when relay Applying CONTROL input during timing will have effect timing state relay. Shot: Output relay turned applying CONTROL input with input voltage present application input voltage with CONTROL input Immediately upon either, timing initiated with output relay turning completion selected time interval. Applying CONTROL input after time will reset timer, turn output relay initiate another time interval. continuously when output relay flashes when relay Applying CONTROL input during timing will have effect timing state relay. Delay: Output relay turned applying CONTROL input with input voltage present application input voltage with CONTROL input time interval will started removing CONTROL input with output relay turning completion time interval. Reapplying CONTROL during timing will reset time zero inhibit timing until removed. when CONTROL input flashing during timing continuously when output relay off. Interval: Output relay turned programmed time interval applying input voltage. flashes when output relay continuously when output relay off. Applying CONTROL input will have effect timing state relay. Timing Range 99.9 Seconds Timing Range Seconds Timing Range 99.9 Minutes Timing Range Minutes Timing Range 99.9 Hours Timing Range Hours Timing Range 9990 Hours Delay: Output relay programmed time interval which started applying input voltage. flashes when output relay continuously when output relay Applying CONTROL input will have effect timing state relay. show time status. functional explanation details. REPEAT SHOT DELAY INTERVAL DELAY TIME BASE TIME Time Base: 1/10 Seconds Seconds 1/10 Minutes Minutes 1/10 Hours Hours Hours Tyco Electronics Corporation P&B, Winston-Salem, 27102 Technical Support Center: 1-800-522-6752, www.pandbrelays.com Specifications availability subject change without notice. 13C2665 Printed U.S.A. IH/4-00 Other recent searchesMUR405 - MUR405 MUR405 Datasheet MUR410 - MUR410 MUR410 Datasheet MUR415 - MUR415 MUR415 Datasheet MUR420 - MUR420 MUR420 Datasheet MUR440 - MUR440 MUR440 Datasheet MUR460 - MUR460 MUR460 Datasheet MCM67B618B - MCM67B618B MCM67B618B Datasheet L4931ABxx - L4931ABxx L4931ABxx Datasheet L4931Cxx - L4931Cxx L4931Cxx Datasheet EVK71-050 - EVK71-050 EVK71-050 Datasheet CD54HC221 - CD54HC221 CD54HC221 Datasheet BZV58 - BZV58 BZV58 Datasheet BYT51 - BYT51 BYT51 Datasheet
Privacy Policy | Disclaimer |