| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Wide input voltage ranges from 8.385 isolated outputs Class equipment
Top Searches for this datasheetWatt DC-DC Converters Wide input voltage ranges from 8.385 isolated outputs Class equipment Rugged electrical mechanical design Fully isolated outputs Operating ambient temperature range -40.71°C with convection cooling Selection chart Output Output Output Output Type Input Voltage 8.35 1001-7R 1301-7R 1501-7R 1601-7R 2320-7R 2540-7R 2660-7R 2320-7R 2540-7R 2660-7R Type Input Voltage 28.140 1001-7R 1301-7R 1501-7R 1601-7R 2320-7R 2540-7R 2660-7R 2320-7R 2540-7R 2660-7R Type Input Voltage 14.70 1001-7R 1301-7R 1501-7R 1601-7R 2320-7R 2540-7R 2660-7R 2320-7R 2540-7R 2660-7R Type Input Voltage 44.220 1001-7R 1301-7R 1501-7R 1601-7R 2320-7R 2540-7R 2660-7R 2320-7R 2540-7R 2660-7R Type Input Voltage 20.100 1001-7R 1301-7R 1501-7R 1601-7R 2320-7R 2540-7R 2660-7R 2320-7R 2540-7R 2660-7R Type Input Voltage 67.385 1001-7R 1301-7R 1501-7R 1601-7R 2320-7R 2540-7R 2660-7R 2320-7R 2540-7R 2660-7R Options Options www.power-one.com Edition 1/04.2002 Cassette Style Input Input voltage Inrush current limitation wide-input ranges (1:5) thermistor refer selection chart Output Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation Minimum load Current limitation Operation parallel Hold-up time nom, nom, ±0.6% IEC/EN 61204, total typ. mVpp min.Ui max, typ. ±0.3% nom, 10.100% nom, symmetrical output load typ. 0.4% required rectangular characteristic typ. 110% current limitation nom, nom, CS/DS/ES/FS with ext. diode input line 12.40 nom, nom, AS/BS with ext. diode input line typ. Control protection Input reverse polarity Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature Output voltage adjustment Inhibit Status indication built-in fuse user accessible typ. typ. 108% varistor suppressor diode no-load, overload short circuit proof suppressor diode each output switch-off with auto restart input, output(s) disabled open circuit LEDs: inhibit, overload typ. 130% typ. 100°C 0.110% Safety Approvals Class equipment Protection degree Electric strength test voltage 60950, 1950, 22.2 class I/case O/case Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions IEC/EN 61000-4-2, level (8/15 IEC/EN 61000-4-3, level V/m) IEC/EN 61000-4-4, level (2/4 IEC/EN 61000-4-5, level IEC/EN 61000-4-6, level CISPR 22/EN 55022, conducted criterion criterion criterion criterion criterion class www.power-one.com Edition 1/04.2002 Environmental Operating ambient temperature Operating case temperature Storage temperature Damp heat Vibration, sinusoidal Shock Bump Random vibration MTBF Watt DC-DC Converters nom, nom, convection cooled nom, operational IEC/EN 60068-2-3, IEC/EN 60068-2-6, 10.60/60.2000 IEC/EN 60068-2-27, IEC/EN 60068-2-29, IEC/EN 60068-2-64, 20.500 MIL-HDBK-217F, 40°C -25.71°C -25.95°C -40.100°C days 0.35 mm/5 500'000 Options Extended temperature range -40.71°C, ambient, operating Electronic inrush current limitation Output voltage adjustment 40.110% nom, excludes feature vice versa Input and/or output undervoltage monitoring, excludes option Input and/or output undervoltage monitoring (VME), excludes option Current sharing Cooling plate D0.D9 allocation Vo1+ Vo1+ Vo1- Vo1- AS.ES 1000 Output Output Sense Sense Control Inhibit Save data ACFAIL Current sharing Protective earth Input Input Vo2+ Vo2+ Vo2- Vo2- Vo1+ Vo1- S10002 AS.ES 2000 Output Output Output Control Inhibit Save data Current sharing Protective earth Input Input www.power-one.com Edition 1/04.2002 Cassette Style Mechanical data Tolerances ±0.3 (0.012") unless otherwise indicated. 171.93 (DIN 41494) (6.77") Measuring point case temperature European Projection (3U) 4.37") (3.93") Test jacks Option (Uo) Option (Uto) Option (Uti) (5.98") 11.8 (0.46") (2.36") 168.5 (6.63") 09004 Accessories Front panels (Schroff/Intermas) Mating connectors with screw, solder, fast-on press-fit terminals Connector retention facilities code system connector coding Chassis wall mounting plates frontal access Universal mounting brackets chassis DIN-rail mounting 25.9 (1.02") www.power-one.com Edition 1/04.2002 Other recent searchesUT138F - UT138F UT138F Datasheet TLC0831C - TLC0831C TLC0831C Datasheet TLC0831I - TLC0831I TLC0831I Datasheet TLC0832C - TLC0832C TLC0832C Datasheet TLC0832I - TLC0832I TLC0832I Datasheet ADC0831 - ADC0831 ADC0831 Datasheet ADC0832 - ADC0832 ADC0832 Datasheet SUD50P04-13L - SUD50P04-13L SUD50P04-13L Datasheet PT6313-S - PT6313-S PT6313-S Datasheet ISL59424EVAL1 - ISL59424EVAL1 ISL59424EVAL1 Datasheet FDC6020C - FDC6020C FDC6020C Datasheet EV2010 - EV2010 EV2010 Datasheet AP2204 - AP2204 AP2204 Datasheet
Privacy Policy | Disclaimer |