| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
25-110 Watts Universal Input Single, Dual, Triple Quad Outputs Op
Top Searches for this datasheetUniversal Input Switchers SERIES 25-110 Watts Universal Input Single, Dual, Triple Quad Outputs Optional Safety Covers Medical Approved Versions High Reliability International Safety Approvals Input voltage Input Frequency Inrush Current Hold Time Output Voltage Line Regulation Load Regulation Ripple Noise Short Circuit Overload Protection Overvoltage Protection Efficiency Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Vibration Safety Approvals (standard models) Safety Approvals (medical models) Overall Power Limit output single output shuts unit down typical Derate above requires forced cooling Table condensing 0.75 over axis. FCC, 0871 curve 110, EN55022 curve conducted noise FCC, 0871 curve 110, medical spec. UL1950 recognised, certified, compliant EN60590/IEC950/IEC1010 approved (NFS75 IEC1010) BS6301 approved most models, contact office file numbers UL2601 (NFS40 NFS110), UL544 (NFS50), patient connect applications CSA22.2 certified File 41062, patient connect applications 601/VDE 0750 File 2559 (NFS40), 2874(NFS110), critical patient connect applications. MTBF Notes each model 85-264 (120-370 47-440 input `cold start' typical load Table, main output some auxiliary outputs adjustable (not NFS25) ±0.2% 40/75 ±0.5%, 42/50 ±0.3%, 80/110 ±0.1% Tables Tables Tel: (0)118 5515 Tel: (0)700 9977 1000 Power Supplies Output Power Output Voltage +5.1 +12.0 -12.0 +5.1 +12.0 -12.0 +5.1 +12.0 +5.1 +12.0 -5.0 +5.1 +12.0 -12.0 +5.0 +12.0 -12.0 +5.0 +15.0 -15.0 +5.0 +12.0 +15.0 +24.0 Minimum(10)(11) Output Currents Maximum(1) Maximum(2) 2.00 1.50 0.20 2.00 0.20 0.20 2.00 1.50 3.00 5.00 2.00 2.00 0.35 0.50 3.00 5.00 2.00 2.00 0.35 0.50 4.00 5.00 0.35 0.50 0.35 0.50 3.00 5.00 2.00 2.00 0.35 0.50 6.00 8.00 3.30 4.00 2.60 3.30 1.60 2.00 Peak(3) 12.0 Ripple P-P(4) Total Regulation(5) +10%/-3% Model Number NFS25-7608 NFS25-7628(6) NFS25-7629 Universal Input Switchers 25-110 Watts Series NFS40-7607 NFS40-7608** NFS40-7628(6) NFS40-7610** NFS40-7605** NFS40-7612** NFS40-7615** NFS40-7624** Medical Approved versions available replace 76xx with 79xx Natural convection cooled. Forced air, atmosphere, maximum. Peak output current lasting less than seconds with duty cycle less than Peak output current lasting less than seconds with duty cycle less than 10%. During peak loading, outputs outside total regulation limits. bandwidth, peak peak, measured differentially. Total Regulation defined static output regulation including initial tolerance, line voltage within stated limits, load currents within stated limits, output voltages adjusted their factory settings. Also, 0.5I(A)/I(B)3 0.25 I(A)/I(B) maintain stated regulation. NFS25&40-7628 have separately regulated output. loading condition note does apply. order meet safety requirements, non-metallic standoff mandatory hole specified mechanical drawing (below). ground mounting hole near allows system grounding through metal standoff. improve EMI/RFI Conducted noise, ground mounting hole near output connector should connected with ground mounting hole near metal standoffs attached common metal chassis. This connection also significantly attenuates common mode noise. MTBF 170,00 MIL217E with load. load required output obtain full current from negative output. CONNECTIONS NFS25-7608/28/29 Live Neutral Return Return (NC/29) NFS40-7607/8/28 Live Neutral Return Return V/-12 NFS40-7610 Live Neutral Return Return NFS40-7605 Live Neutral Return Return Return NFS40-7612 Live Neutral Return Return Return NFS40-7615 Live Neutral Return Return Return NFS40-7624 Live Neutral Return Return Return Safety Earth Ground Other output voltage versions available. Consult office details. mating connector Molex 09-50-3031 with Molex 08-50-0105 crimp terminal. mating connector Molex 09-91-0600 with Molex 08-50-0105 crimp terminal. Mating connector kits available, order Part 25/40W minimum load required operation, above. Power sharing between outputs possible, contact sales office details. standard L-bracket cover available mounting which contains screws, connectors necessary hardware. 3.15 Website: www.xpplc.com E-mail: sales@xpplc.com Output Power Output Voltage +5.1 (l2) +5.1 (l2) +5.1 (l2) +5.1 (l2) +5.1 (l2) isolated +5.1 (l2) +5.1 (l2) Minimum(6) Output Currents Maximum(1) Maximum(2) Peak(3) Ripple Pk-Pk(4) Total Regulation(5) ±2.5% ±2.5% ±2.5% ±2.5% Model Number NFS42-7608 NFS42-7627 NFS42-7610 NFS50-7608** NFS50-7608M NFS50-7610 NFS50-7601 Medical approved version available model NFS50-7908 Convection Cooled. Forced Air, Atmosphere. Peak outputs lasting less than minute with duty factor less than During peak loading, output outside total regulation limits. bandwidth, peak peak, measured differentially. Total Regulation defined static output regulation including initial tolerance, line voltage within stated limits, load currents within stated limits, output voltages adjusted their factory setting. (continued) achieve stated regulation following applies: 42-7608 0.25 42-7627 42-7610 50-7608/08M 50-7610/01 where MTBF 230,000 (NFS 42), 160,000 (NFS with load MECHANICAL DETAILS WATT MODELS Connections Ground Ground Ground Mating Connector Molex 09-50-3031 with Molex 08-50-0105 crimp terminal Mating Connector Molex 22-01-1403 with Molex 08-50-0031 crimp terminal Mating Connector available, order Part NFS42/50 NFS42 7608/10/27, NFS50 7608/10 NFS42-7627 Live Neutral Return NFS42-7610 NFS50-7610 Live Neutral Return NFS42-7608 NFS50-7608 Live Neutral Return Safety Covers available Alternative Connector NFS50-7608 NFS50-7608 also available with vertical Molex connector, designated NFS50-7608M. Electrical specifications same with exception that third output floating. auxiliaries therefore configured When used provide output recommend fitting 1N4001 diode across isolated prevent damage regulator. Connections Return (Floating) Return Return Return Return NFS50-7608 Neutral Live NFS50-7601 Neutral Live NFS50 7608M/7601 Safety Covers available Mating Connector NFS50-7608 Mating Connector Molex 09-91-0600 with Molex 08-50-0105 crimp terminal Mating Connector available, order Part NFS42/50 Tel: (0)118 5515 Tel: (0)700 9977 1000 Power Supplies Maximum Power(1) Output Voltage +5.1 +12.0 -12.0 -5.0 +5.1 +24.0 +12.0 -12.0 +5.1 +15.0 -15.0 -5.0 Minimum Output Currents Maximum(1) Maximum(2) 12.0 12.0 10.0 10.0 10.0 16.0 20.0 Peak(3) 10.0 20.0 20.0 20.0 20.0 20.0 22.0 Ripple P-P(4) Total Regulation(5)(6) +10%/-5% +10%/-5% +10%/-5% Model Number NFS75-7608 NFS80-7602 NFS80-7606 Universal Input Switchers 25-110 Watts Series NFS110-7601P* NFS110-7602P* NFS110-7604P* NFS110-7605* NFS110-7612* NFS110-7615* NFS110-7624* Medical Approved versions available models marked with replace 76xx with 79xx Natural convection cooled, maximum. Forced air, atmosphere, Maximum. Peak output current lasting less than seconds with duty cycle less than total peak power must exceed W/110 bandwidth, peak peak, measured differentially. Total Regulation defined static output regulation including initial tolerance, line voltage within stated limited, load current within stated limits, output voltages, adjusted their factory settings. 7602 model l(A)/l(B) <5.0 stated regulation output. output will maintain regulation l(A) MTBF 50,000 (NFS 75), 125,000 (NFS 110) with load. Output floating must referenced positive negative, connecting common pins 4-7. MECHANICAL DETAILS WATT MODELS NFS75 Model Connections 6,7,8 9,10 NFS75-7608 NEUTRAL LIVE GROUND Mating Connector Molex 09-91-0500 Mating Connector Molex 09-91-1000 Crimp Terminals Molex series 2878 Safety Cover available NFS75 NFS110 Overall height (48.3) Dimensions inches (mm) NFS110 Model Connections 1,2,3 4,5,6,7 NFS80-76XX GROUND NEUTRAL LIVE V/+15 -12/-15 Ret* V/-15 NFS110-MULTI GROUND NEUTRAL LIVE V/+15 P.F. V/-15 V/+24 NFS110-SINGLE GROUND NEUTRAL LIVE N.C. N.C. N.C. Pins floating output, which referenced -ve. with respect Either must connected (pins 4-7) proper operation. mating connector Molex 09-91-0500 mating connector Molex 09-91-1300 Crimp Terminals Molex Series 2878 Website: www.xpplc.com E-mail: sales@xpplc.com Other recent searchesU74LVC2G32 - U74LVC2G32 U74LVC2G32 Datasheet S20VTA - S20VTA S20VTA Datasheet REJ10B0150-0100H - REJ10B0150-0100H REJ10B0150-0100H Datasheet R143AC - R143AC R143AC Datasheet PC1600 - PC1600 PC1600 Datasheet PC2100 - PC2100 PC2100 Datasheet NTE2396 - NTE2396 NTE2396 Datasheet FIM83010 - FIM83010 FIM83010 Datasheet CPC1560 - CPC1560 CPC1560 Datasheet BUH713 - BUH713 BUH713 Datasheet
Privacy Policy | Disclaimer |