| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Threaded holes bottom side surface used mounting (except, side mountin
Top Searches for this datasheetPOWER SUPPLIES DUAL TRACKING OUTPUTS INSTALLATION OPERATION Threaded holes bottom side surface used mounting (except, side mounting TH11 case size), supply rear mounted using same holes that attach rear cover plate. accessory Mounting (model Gold power supplies model Narrow Profile power supplies) available enable mounting power supply when opposite side mounting surface inaccessible. Even relatively small amount flowing around through power supply will significantly reduce rise temperature resulting from operation, therefore temperature critical components within improving both reliability stability. Avoid blocking flow through vented surfaces. perforated bottom supply mounted solid surface, spacers least 3/16" thick between surface which fastened, permit convection flow, punch ventilation holes mounting surface. Allow free circulate around heat sinks. Space least inch away from surrounding objects. Make connections before applying input power. SENSING TERMINALS MUST CONNECTED output terminals, either barrier strip power supply load. Failure have sense terminals connected will affect output voltage (usually causing higher than rating supply, unadjustable), result permanent damage both power supply load. voltage drops output voltage leads (which degrade regulation) objectionable, local sensing used; leave place jumpers provided with power supply barrier strip (connecting +SENS terminal -SENS terminal). However, best possible regulation load required, then remove jumpers additional leads connect sense terminals output leads load, shown schematic. This configuration permits power supply sense compensate voltage actually across load. Note that remote sensing capable compensating only limited wiring drops. voltage across load, plus voltage drops through wiring, must within output voltage range supply voltage load remain within load regulation specification. there possibility voltage from another source (another power supply, battery, transients, etc.) being applied power supply's output terminals, protect power supply using diode series with lead another series with lead. attempt directly parallel outputs power supplies. This would result current flowing from higher-set output into lower-set output, probable damage both circuits. Outputs used series obtain higher voltage provided that reverse-biased diode, having current ratings exceeding combined output, used across each output; however, keep mind that output current drawn cannot exceed output current rating lowest rated supply used. Frequent fuse failure symptomatic power supply overload, short circuited output, tripped overvoltage protector, power supply failure. overfuse; this result damage power supply. input power contains large voltage spikes (`noise') induced switching high currents, inductive loads, electro-mechanical components, etc., input power leads supply should include some means transient suppression. Otherwise, portion noise coupled through supply load. Also, supply could damaged. means suppression that easiest install capacitor metal oxide surge suppressor (MOV) across input terminals supply. extremely severe cases, chokes series with each side line also required. These power supplies operate constant voltage sources when used load current equal less than their ratings. power supply overloaded, current limit circuit will automatically reduce output voltage, will then attempt recover normal operating point. Therefore, TRANSITORY OVERLOAD RESULTS MOMENTARY DROP OUTPUT VOLTAGE. However, overload still present when voltage attempts recover, voltage will continue alternately drop recover, which will appear sawtooth oscillation output. operate power supply this mode; reduce load that output current equal less than rating supply will drawn. FRONT COVER TN6T TN8H cases. dimension includes TRANSISTORcase. TN6T case HEATSINK TN8H 2.87 HEATSINK Voltage Adjust Voltage Adj. TRANSISTOR 1.68 1.31 .375 (Typ.) Barrier Strip .375 with 6-32 (Typ.) terminal screws BOTTOM SIDE MOUNTING Maximum incursion screws into mounting holes: 5/16" (.312") cases. 3/16" (.187") cases. (max) BOTTOM MOUNTING 8-32 threaded holes(4). (6-32 cases.) SIDE MOUNTING 8-32 threaded holes(4). (6-32 cases.) TH11 case. Applies -certified models: SPECIAL MEASURES LIMITATIONS maintain compliance with Voltage Directive, following special measures limitations must observed when product placed into service: Marked Voltage Directive. Evaluated Pollution Degree environment. Intended connection Class TN-S power system. Models with outputs volts less considered have SELV outputs. Models with outputs greater than volts considered have hazardous voltage outputs should located Operator Access area product. Models with output ratings less than 240VA considered have nonhazardous energy levels. Models with output ratings 240VA greater considered have hazardous energy levels. Models without built-in fuse require external fuse used ungrounded (hot) side line. catalog electrical mechanical specifications. Ground terminal must bonded protective earth. Intended installed within end-use equipment. REAR MOUNTING cases, remove original screws(4) 8-32 Type self-tapping screws. They should extend least 5/16" (0.312") into power supply case. REAR MOUNTING cases, remove original 6-32 screws(4). These screws then used mounting, provided they extend least 1/4" (0.250") into power supply case. Case Size TG13 TH11 TN6T TN8H 5.09 6.59 9.25 13.25 11.25 6.59 8.47 5.12 5.12 5.12 5.12 7.37 3.84 4.68 4.50 4.50 4.50 4.50 6.75 3.12 3.12 4.56 1.31 1.31 1.25 1.25 1.25 1.25 2.73 2.73 2.73 2.73 2.73 4.36 1.44 1.44 1.44 1.44 2.38 Approx. Weight complete Acopian catalog available Internet www.acopian.com P.O. 638, Easton, 18044 Phone: (610) 258-5441 FAX: (610) 258-2842 OPIAN SUPPL MADE REV2 3.44 3.44 3.44 3.44 10.0 5.12 .156 .156 POWER SUPPLIES DUAL TRACKING OUTPUTS Acopian Dual Tracking power supplies convenient-to-use sources dual (plus minus) tracking voltages required powering operational amplifiers related circuits. Provision remote sensing electronic short circuit protection standard features, built-in overvoltage protection available option. They conservatively rated operation ambient temperatures +71°C. Models case sizes TN6T TN8H were specifically designed limited-space applications, only 1.68" high. Depending upon output current rating, either pairs used parallel single used. Output Connection Variations SENS LOAD +SENSE SENS LOAD SENS LOAD INPUT COMMON SENS OVERVOLTAGE PROTECTOR SENS LOAD LOAD SENS -SENSE LOAD CASE (optional) -125 VAC, 50-400Hz (Standard) -250 VAC, 50-400Hz (When model number ends -230) MODEL NUMBER indicates included options; prefix overvoltage protection suffix fungus proofing suffix terminal strip cover suffix -230: 230v input numbers shown outside apply dual inline package. numbers circles apply metal package. CAUTION: provide protection from risk fire, include input wiring 250V time-delay fuse with rating listed below: (These fuse ratings 115V input models only; contact factory fuse ratings 230V input models.) MODEL TD5-75 TD5-150 TD5-250 TD12-100 TD12-160 TD12-250 TD12-450 TD12-850 TD15-40 TD15-100 TD15-160 TD15-250 TD15-450 TD15-850 FD12-50A LD12-100 FD15-50A LD15-100 Fuse size 6/10 1-1/4 7/10 1-1/4 8/10 1-1/2 6-1/4 4/10 8/10 Other recent searchesSP5659 - SP5659 SP5659 Datasheet DS4296 - DS4296 DS4296 Datasheet SCHS116C - SCHS116C SCHS116C Datasheet PT15-21C - PT15-21C PT15-21C Datasheet PCMB104E-3R3MS - PCMB104E-3R3MS PCMB104E-3R3MS Datasheet FC11BL - FC11BL FC11BL Datasheet CP750 - CP750 CP750 Datasheet CP751 - CP751 CP751 Datasheet
Privacy Policy | Disclaimer |