Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet




Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Contents
Page
Standards
Cutler-Hammer Moulded Case Circuit Breakers designed conform with following international standards:
Standards General Information Electrical Characteristics/ Technical Data Electronic Trip Units. 10-12 Catalogue Numbers/ Termination Accessories G-Frame, 16-100 Amperes E-Frame, 16-225 Amperes 14-15 J-Frame, 100-250 Amperes 16-17 K-Frame, 63-400 Amperes 18-19 L-Frame, 315-800 Amperes 20-21 N-Frame, 400-1250 Amperes 22-25 R-Frame, 800-2500 Amperes 26-29 Motor Circuit Protectors. Frame Sizes through 31-32 Handle Mechanisms. 33-35 Accessories Modifications 36-38 Time-Current Curves 39-40 Current Limiting Curves. Dimensions 42-43 Sales Offices Typical Specifications Inside Back Cover
Global Third Party Certification
Certification marks assure product compliance with total standard third party witnessing tests globally recognized independent certification organizations. KEMA highly recognized, completely independent international organization that offers certification inspection facilities equipment many industries. KEMAKEUR mark highest certification electrical product receive from KEMA. 60947-2 Moulded Case Circuit Breakers KEMA tested certified. What does KEMA-KEUR rating mean you? means independent testing house. KEMA Registered Quality tested certified these products 60947-2 standards. addition, KEMA conducting ongoing follow-up witness test programs assure 60947-2 compliance maintain KEMA Certification mark, KEMA-KEUR been well-known highly respected independent mark over years, symbol quality assurance that enjoys confidence both manufacturers consumers. Cutler-Hammer also offers complete line Moulded Case Circuit Breakers, listed accordance with well C22.2 certified also available. Both independent third party testing houses that continue assure that Cutler-Hammer Moulded Case Circuit Breakers meet their exacting standards through regularly scheduled follow-up testing inspections.
Australian Standard 2184 3947-2 Moulded Case Circuit Breakers. British Standards Institution Standard 4752: Part Switchgear Control Gear Part Circuit Breakers. International Electrotechnical Commission Recommendations 60947.2 Circuit Breakers. Japanese T-Mark Standard Moulded Case Circuit Breakers. National Electrical Manufacturers Association Standards Publication AB1-1975 Moulded Case Circuit Breakers. South African Bureau Standards, Standard SABS 156, Standard Specification Moulded Case Circuit Breakers. Swiss Electro-Technical Association Standard 947.2, Safety Regulations Circuit Breakers. Union Technique l'Electricite Standard 63-120, Voltage Switchgear Control Gear Circuit Breaker Requirements. Verband Deutscher Elektrotechnike (Association German Electrical Engineers) Standard 0660, Voltage Switchgear Control Gear, Circuit Breakers.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
General Information
Cutler-Hammer Moulded Case Circuit Breakers provide increased performance considerably less space than standard circuit breakers comparable fusible devices. Reduced system costs also realized because Cutler-Hammer Circuit Breakers used series rated systems, allowing lower interrupting circuit breakers downstream. Cutler-Hammer Circuit Breakers meet applicable 60947-2 standards, have been assigned ultimate service interrupting ratings 60947-2, employ adjustable thermal adjustable magnetic trips. Cutler-Hammer family includes seven frame sizes ratings from 2500 amperes. Each frame size offers choice several interrupting capacities volts (200 volts ac). This provides greater design flexibility than ever before possible while also helping save space. Cutler-Hammer Circuit Breakers virtually eliminate need redesign they used replace older circuit breakers same panelboards, feeder pillars, busbar trunking tap-offs, individual enclosures, machine tool control panels, motor control centres. most cases, same connecting straps, studs, handle mechanisms retained used. Standard calibration 40°C. applications high ambient temperature conditions, 50°C factory calibration available. Cutler-Hammer Circuit Breakers also provided applications. Interrupting ratings ampere frame have been achieved three-pole breakers series volts
Most Logically Designed Contact Assembly flexibility outstanding performance characteristics CutlerHammer Circuit Breakers made possible most logically designed contact assemblies circuit breaker history. Based previously patented Westinghouse contact conductor designs, CutlerHammer contact assembly creates high-speed "blow-open" action when confronts electromechanical forces produced high-level fault currents. Cutler-Hammer Circuit Breakers operated toggle-type handle that mechanically trip-free from handle that contacts cannot held closed against short circuit currents. Tripping overload short circuits clearly indicated position handle. This remarkably fast dependable contact action designed enhance safety. Thorough In-Plant Testing quality, dependability, reliability every Cutler-Hammer Circuit Breaker assured thorough program in-plant testing. calibration tests conducted every pole every circuit breaker verify trip mechanism, operating mechanism, continuity, accuracy.
Certification Cutler-Hammer Circuit Breakers manufactured certified facilities. More Interrupting Capacity Less Space Cutler-Hammer Circuit Breakers physically electrically interchangeable with "Classic" standard line Westinghouse moulded case circuit breakers. This means Cutler-Hammer Breakers ideal upgrading equipment designs retrofitting existing installations. Current Limiting Characteristics Cutler-Hammer Circuit Breakers current limiting because their high repulsion contact arrangement incorporation state-of-the-art extinguishing technology. Operating Mechanisms Cutler-Hammer Circuit Breakers have, their basic version, toggle handle operating mechanism, which also serves switching position indicator. well OFF, further position TRIPPED possible. toggle handle snaps into TRIPPED position breaker tripped overcurrent, short circuit, shunt undervoltage releases. Before circuit breaker reclosed following trip-out, toggle handle must brought beyond position (RESET). circuit breaker then reclosed. additional switching position indicator R-Frame circuit breakers, there windows right left toggle handle, which switching state indicated means colours red, green white corresponding TRIPPED positions respectively.
RESET Tripped
Positions Toggle Handle Drive
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Panelboards both main branch circuit protection devices (G-, N-Frames). Feeder Pillars distribution systems provide main branch circuit protection (E-, R-Frames). Switchgear distribution systems provide main branch circuit protection 2500 amperes (R-Frame). Busbar Trunking Tap-Offs busbar trunking tap-offs provide branch circuit protection (F-Frame); provide feeder branch circuit protection (J-, L-Frames). Individual Enclosures Completely assembled enclosures meet specific customer requirements (G-, R-Frames). Machine Tool Control Panels Motor Control Centres Applied specific equipment requirements (G-, L-Frames). Additional Applications Special versions each CutlerHammer frame available provide safe equipment control protection mining other applications. Contact your Cutler-Hammer agent distributor additional information.
Panelboard
Busbar Trunking Tap-Off
Individual Circuit Breaker Enclosure Machine Tool Control Panel
Switchboard
Typical Cutler-Hammer Applications
Frame Continuous Ampere Rating Range Type Trip Unit Adjustable Thermal Fixed Magnetic Fixed Thermal Fixed Magnetic Adjustable Thermal Adjustable Magnetic Adjustable Thermal Fixed Magnetic Earth Leakage Digitrip Electronic Trip Units Moulded Case Switch
16-100 16-125 125-250 63-400 315-800 400-1250 800-2500
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Electrical Characteristics
Maximum Rated Current (Amperes) Breaker Type
Breaker Capacity rms) 50-60 60947-2 220-240 380-415 660-690 NEMA Number Poles Ampere Range Trip Units 16-125A 16-125A 63-250A
Adjustable Thermal Magnetic
Adjustable Thermal Magnetic
Interchangeable Built-in Thermal Magnetic Fixed Thermal Adjustable Thermal Magnetic Solid State LSIG Dimensions (mm) 1-Pole 2-Pole 3-Pole 4-Pole Weight (approximate) Kgs. 1-Pole 123.8
Fixed Fixed 66.7 139.7 254.4 50.8 76.2 2-Pole 3-Pole 1-Pole 0.45 2-Pole 0.91
Fixed 25.4 50.8 76.2 101.6 3-Pole 1.36 4-Pole 1.81 2-Pole 177.8
Adjustable
3-Pole 4-Pole
poles series. KEMA-KEUR listed. R-frame scheduled
2001.
suitable application. 4-pole
ground fault available.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Electrical Characteristics
Maximum Rated Current (Amperes) Breaker Type
Breaker Capacity rms) 50-60 947-2 220-240 380-415 660-690 NEMA Number Poles Ampere Range Trip Units 63-400A 315-630A 700-800A
Adjustable Thermal Magnetic
Adjustable Thermal Magnetic
Digitrip
Digitrip
Interchangeable Built-in Thermal Magnetic Fixed Thermal Adjustable Thermal Magnetic Solid State LSIG Dimensions (mm) 1-Pole 2-Pole 3-Pole 4-Pole Weight (approximate) Kgs. 3-Pole
Adjustable Standard Optional Optional Optional 4-Pole 3-Pole 630A 800A
Adjustable Standard Optional Optional Optional 4-Pole 630A 9.4/800A 11.3
Adjustable Standard Optional Optional Optional
630A 11.1/800A 14.4
KEMA-KEUR listed. R-frame scheduled
2001.
poles series. suitable application. 4-pole
ground fault available.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes
Electrical Characteristics
Maximum Rated Current (Amperes) Breaker Type
800, 1250
1600
1600, 2000, 2500
Breaker Capacity rms) 50-60 947-2 220-240 380-415 660-690 NEMA Number Poles Ampere Range Trip Units
Digitrip Trip Unit Standard
400-1250A
1600A
800-2500A
Digitrip Trip Units
Digitrip
Interchangeable Built-in Thermal Magnetic Fixed Thermal Adjustable Thermal Magnetic Solid State LSIG Dimensions (mm) 1-Pole 2-Pole 3-Pole 4-Pole Weight (approximate) Kgs. 3-Pole 21.3
Standard Optional Optional Optional 4-Pole 28.3 3-Pole
Standard Optional Digitrip 510, 610, 910) Optional Optional (LIG Optional Digitrip 510, 610, 910) Optional 4-Pole
KEMA-KEUR listed. R-frame scheduled
2001. 60947-2 Annex KEMA-KEUR tested.
poles series. suitable application. 4-pole
ground fault available.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Electrical Characteristics
Technical Data Maximum Rated Current Depending Version Rated Insulation Voltage According 947-2 Main Conducting Paths Auxiliary Circuits Rated Impulse Withstand Voltage Uimp Main Conducting Paths Auxiliary Circuits Rated Operational Voltage NEMA Permissible Ambient Temperature Permissible Load Various Ambient Temperatures Close Circuit Breaker, Related Rated Current Circuit Breaker Circuit Breakers Plant Protection 40°C 50°C 55°C 60°C 70°C Circuit Breakers Motor Protection 40°C 50°C 55°C 60°C 70°C Circuit Breakers Starter Combinations Isolating Circuit Breakers 40°C 50°C 55°C 60°C 70°C Rated Short Circuit Breaking Capacity (DC) Circuit Breakers Motor Protection (Time Constant rms) Conducting Conducting Conducting Path Paths Series Paths Series NEMA (Time Constant rms) Conducting Conducting Path Paths Series Main Switch Characteristics According 947-2 Combination with Lockable Rotary Drives Rated Short Circuit Breaking Capacity According 947-2 50/60 Endurance (Operating Cycles) Maximum Switching Frequency Conductor Cross Sections Terminal Types Main Conductors Solid Stranded Finely Stranded with Sleeve Busbar Tightening Torque Terminals Tightening Torque Busbar Connection Pieces Conductor Cross Sections Auxiliary Circuits with Terminal Connection Terminal Strip Solid Finely Stranded with Sleeve With Brought-out Cable Ends Tightening Torque Fitting Screws Power Loss Circuit Breaker Maximum Rated Current (The Power Losses Undervoltage Releases ("r" Releases) Must Observed Necessary) Three-Phase Symmetrical Load) Plant Protection Isolating Circuit Breaker Starter Combinations Motor Protection Permissible Mounting Position
G-Frame 100A 1-Pole 2,3-Pole 1-Pole 2,3-Pole +70°C 100%
E125-Frame 125A
J250-Frame 200/250A
K-Frame 315/400A
L-Frame 500/630/800A
N-Frame 800/1250A
R-Frame 1600/2000/2500A
600Y/347 +70°C
+70°C
+70°C
+70°C
+60°C 100%
+60°C 100% 100% 100% 100%
100%
100%
100%
100%
100% 100% 100% 100% 100%
100%
100% 100% 100% 100% 100%
100%
100% 100%
100% 100%
100% 100%
100% 100%
100%
100% 100% 100% 100%
Max.
Max.
Max.
Max.
rms)
Rated Short Circuit Breaking Capacity Table Pages 4-5-6 10,000 Terminals 10,000 Terminals 50/70 10,000 Terminals 8,000 Terminals 8,000 Flat Terminals 800A 3,000 Flat Terminals Optional 3,000 Flat Terminals Optional
0.75 0.75
0.75 0.75
0.75 0.75 0.75 0.75 0.75 0.75 2x2.5 2x2.5 0.82 (AWG 0.82 (AWG 0.82 (AWG 0.82 (AWG 0.82 (AWG
87/210 87/210
220/270/400 220/270/400
Thermal overload release
lower value.
Thermal overload release upper
value, respecting fixed-setting thermal overload releases.
suitable switching.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Electrical Characteristics
Technical Data G-Frame E125-Frame J250-Frame K-Frame L-Frame N-Frame R-Frame
Auxiliary Switches Rated Thermal Current Rated Making Capacity (AC-15) Rated Operational Voltage Rated Operational Current (DC-13) Rated Operational Voltage Rated Operational Current Back-up Fuse Miniature Circuit Breaker Releases Undervoltage Releases ("r" Releases) Response Voltage: Drop (Breaker Tripped) Pickup (Breaker Switched Power Consumption Continuous Operation 50/60 50/60 50/60 48-60V 50/60 110-127V 50/60 208-240V 50/60 380-500V 48-60V 110-125V 220-250V Maximum Opening Time Shunt Trips Shunt Trips ("f" Releases) Response Voltage: Pickup (Breaker Tripped) Power Consumption (Short Time) 50/60 12-24V 50/60 48-60V 50/60 48-127V 50/60 110-240V 50/60 380-440V 50/60 380-600V 50/60 480-600V 240V 230/400/600V 6/3/0.25A 24/125/250V 6/0.5/0.25A 6/4/4A 6/4A 230/400/690V 6/3/0.25A 24/125/240V 6/0.5/0.15A 6/4/4A 6/4A 230/400/690V 6/3/0.25A 24/125/240V 6/0.5/0.15A 6/4/4A 6/4A 230/400/690V 6/3/0.25A 24/125/240V 6/0.5/0.15A 6/4/4A 6/4A 230/400/690V 6/3/0.25A 24/125/240V 6/0.5/0.15A 6/4/4A 6/4A 230/400/690V 6/3/0.25A 24/125/240V 6/0.5/0.15A 6/4/4A 6/4A
35-70% 85-110%
35-70% 85-110% 0.95 0.72 1.15-1.78 0.96 -1.25 1.28 -1.68 -3.9 0.88 0.70 1.12-1.76 0.94-1.21 1.45-1.86
35-70% 85-110% 2.5-3.8 -2.4 2.7-3.8 3.4-5.8 2.0-3.1 1.6-2.2 3.1-4
35-70% 85-110% 2.5-3.8 -2.4 2.7-3.8 3.4-5.8 2.0-3.1 1.6-2.2 3.1-4
35-70% 85-110% 2.5-3.8 1.8-2.4 2.7-3.8 3.4-5.8 2.0-3.1 1.6-2.2 3.1-4
35-70% 85-110% 2.3-4.1 3.4-4.2 4.8-6.5 6.8-12.0 -5.5 2.9-3.6 4.8-6.3
35-70% 85-110% 3.4-6.0 3.3-3.8 4.2-7.2 10.0 4.8-7.2 3.3-3.8 6.6-7.5
70-110% 135-500
70-110% 10-41 139-210 83-360 418-1080 29-120 475-720 99-121
0-110% 87-405 710-1105 66-432 127-188 34-60 164-631 830-1580 112-150 40-58
70-110% 87-405 710-1105 66-432 127-188 34-60 164-631 830-1580 112-150 40-58
70-110% 81-701 58-90 118-665 125-181 43-79 79-1000 18-31 112-150 38-52
70-110% 86-631 48-71 81-505 43-68 41-69 46-405 58-94 74-98 38-49
70-110% 177-1207 443-731 323-1466 1193-1641 197-312 289-865 468-696 363-473 513-665
12-24V 48-60V 110-125V 220-250V Maximum Load Duration Maximum Opening Time
Interrupts Automatically
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Electrical Characteristics
Switching Duty L-Frame circuit breakers also suitable switching currents. R-Frame circuit breakers, FWMP, KWMP, LWMP circuit breakers motor protection suitable currents solid state overcurrent release system. switching currents, however, maximum permissible voltage conducting path considered. voltages higher than volts, series connection three conducting paths required.
NSI-5180
4-Pole Circuit Breakers
Proposed Circuit Maximum Permissible Remarks
Double-pole switching. there risk earth fault, earth fault which occurs immediately eliminated (earth fault monitoring), maximum permissible voltage volts.
NSI-5178a
Double-pole switching (earth system). earthed pole must always assigned individual conducting path, that paths always series event earth fault.
NSI-5179a
Single-pole switching (earthed system). Three conducting paths series. earthed pole must assigned nonswitched conducting path.
current flow through conducting paths maintain thermal tripping characteristics, following circuit arrangements recommended. With trip values instantaneous short circuit release ("n" release) increased 40%.
Single-pole switching (earthed system). Four conducting paths series. earthed pole must assigned nonswitched conducting path.
NSI-5181
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Multi-Function Electronic Trip Units Applications
DigitripRMS Trip Units True Sensing Digitrip Trip Units utilize proprietary SUREChip SuRE PlusChip microprocessor-based intelligence provide true sensing, permitting increased accuracy reliable system protection. True sensing susceptible nuisance tripping when waveforms containing high harmonic currents present. Digitrip Digitrip Electronic Trip Units available with Cutler-Hammer Circuit Breakers R-Frames through 2500 amperes. Digitrip Trip Units available four styles with either fixed adjustable rating plugs which establishes continuous ampere rating breaker. Rating Plugs Digitrip Trip Units incorporate rating plugs that interchangeable within specific circuit breaker frame. This provides user with versatility when establishing continuous current rating breaker. Rating plugs frequency sensitive specified applications. Both fixed adjustable rating plugs available, providing further flexibility when applied selectively coordinated systems. Note: Digitrip rating plugs interchangeable with SELTRONICrating plugs. Curve Shaping When selectively coordinated systems called for, Digitrip will provide cost-effective solution variety applications. standard Digitrip includes adjustable short time pickup setting encompassing ramp function which provides basic curve shaping function. optional Digitrip provides additional flat response short time delay adjustments instantaneous setting provide curve shaping capability.
Both Digitrip Trip Units available with ground fault pickup flat response ground fault delay which provide trip unit with full function LSIG curve shaping flexibility. Digitrip Trip Units effectively coordinate with both sophisticated upstream power breakers well downstream thermal magnetic breakers.making Digitrip Trip Units costeffective reliable choice selectively coordinated systems. Thermal Memory Digitrip Trip Units incorporate long delay and, when ordered with ground, ground fault thermal memory feature. Thermal memory prevents system from cumulative overheating repeated overcurrent events that occur quick succession.
Digitrip Digitrip 610, Trip Units available with Cutler-Hammer R-Frame Circuit Breakers through 2500 amperes. Digitrip Trip Units provide unparalleled system protection with fixed rating plugs establish continuous ampere rating breaker. Curve Shaping Digitrip Trip Units available with nine curve shaping choices achieved adjusting seven switches front unit optimum system coordination. Maximum curve shaping flexibility provided dependent long short delay adjustments that long delay pickup (Ir) based, depicted front unit blue portion time-current curve. Additional coordination capability provided utilizing short delay ground fault zone selective interlocking features available these trip units.
R-Frame Digitrip 310, Trip Units (Noninterchangeable)
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size
System Diagnostics four Digitrip models trip units provide long delay, short delay, instantaneous, ground fault cause trip LEDs front unit. Digitrip also offer magnitude trip information well remote signal contacts improved system diagnostics. System Monitoring Digitrip Trip Units have capability monitor phase currents well neutral ground currents. This information displayed large digital display mounted unit. Digitrip Trip Units also provide user with power energy monitoring capability. Peak power demand, present power
demand, total energy well forward reverse energy monitored with this unit. Digitrip Trip Units have additional capability monitoring line line voltage well system power factor. Both parameters displayed digital display window supported LEDs indicate which parameter being displayed. Harmonics Monitoring Digitrip Trip Units capable displaying values current harmonics digital display window. Percentage harmonic content monitored each phase, neutral ground, 27th harmonic. Additionally, total harmonic distortion value calculated displayed.
Communications Digitrip have built-in communications options allow protection, monitoring, control information transmitted back central location Cutler-Hammer PowerNet System. Field Testing Integral field testing capability provided Trip Units. additional test needed perform both trip trip field testing.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Digitrip Electronic Trip Unit Selection Guide
Digitrip
Breaker Type
Cutler-Hammer Frame(s) Ampere Rating Interrupting Rating 415V R-Frames 70A-2500A Ordering Options 0.5-1.0 (ln) Seconds 200-800% (ln) Var/Frame I-500 Test LSI, LSIG 0.5-1.0 (ln) Seconds 200-800% (ln) I-300 200-800% (ln) Var/Frame I-500 Test R-Frame 800A-2500A LSI, LIG, LSG, LSIG 0.5-1.0 (ln) 2-24 Seconds 0.85 200-600% (Ir) 100-500 100-500 200-600% (ln) 25-100% (ln) 100-500 I-500 Integral R-Frame 800A-2500A LSI, LIG, LSG, LSIG 0.5-1.0 (ln) 2-24 Seconds 0.85 200-600% (Ir) 100-500 100-500 200-600% (ln) 25-100% (ln) 100-500 I-500 Integral
Trip Unit Sensing
Sensing
Protection Coordination
Protection
Fixed Rating Plug (In) Overtemperature Trip Long Delay Adjustable Rating Plug (In) Long Delay Setting Long Delay Time Long Delay Thermal Memory High Load Alarm Short Short Delay Setting Delay Short Delay Time Short Delay Time Flat Short Delay Time InstantaInstantaneous Setting neous Discriminator Instantaneous Override Ground Ground Fault Setting Fault Fault Delay Ground Fault Delay Flat Ground Fault Ground Fault Thermal Memory
System Diagnostics
Cause Trip LEDs Magnitude Trip Information Remote Signal Contacts
System Monitoring
Digital Display Current Voltage Power Energy Power Quality Harmonics Power Factor
System Communications
PowerNet
Field Testing
Testing Method
adjustable rating plug Yes, with addition Energy Sentinal. exceed 1200A.
only. 2500A R-frame 200-600% (In)
Rating plug rating. LDPU setting.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 16-100 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Standard Interrupting Capacity Catalogue Number Maximum Type 1-Pole 2-Pole 3-Pole Maximum
Fixed Thermal/Fixed Magnetic Circuit Breakers Sealed Breakers with Noninterchangeable Trip Units Line Load Terminals GWF1016 GWF1020 GWF1025 GWF1032 GWF1040 GWF1050 GWF1063 GWF1080 GWF1100 GWF2016 GWF2020 GWF2025 GWF2032 GWF2040 GWF2050 GWF2063 GWF2080 GWF2100 GWF3016 GWF3020 GWF3025 GWF3032 GWF3040 GWF3050 GWF3063 GWF3080 GWF3100
Terminals (Factory Fitted Only)
Frame Amperes Terminal Type Wire Type Wire Range
16-100
Pressure Type
Copper
2.5-50
Special 50°C rating available. Order
description.
direct supersedure fixed
thermal magnetic breaker.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 15-125 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Rating 415/480 1-Pole Fixed Thermal Fixed Magnetic 2-Pole Fixed Thermal Fixed Magnetic 3-Pole Fixed Thermal Fixed Magnetic Adjustable Thermal Fixed Magnetic Thermal Range 4-Pole Fixed Thermal Fixed Magnetic Adjustable Thermal Fixed Magnetic Thermal Range
Complete Circuit Breaker Includes Frame, Trip Unit, Standard Terminals, Mounting Hardware
IEC/CE/UL/CSA 18/18
IEC/CE/UL/CSA 25/25
EGB1015FFG EGB1016FFG EGB1020FFG EGB1025FFG EGB1030FFG EGB1032FFG EGB1035FFG EGB1040FFG EGB1045FFG EGB1050FFG EGB1060FFG EGB1063FFG EGB1070FFG EGB1080FFG EGB1090FFG EGB1100FFG EGB1125FFG
EGB2015FFG EGB2016FFG EGB2020FFG EGB2025FFG EGB2030FFG EGB2032FFG EGB2035FFG EGB2040FFG EGB2045FFG EGB2050FFG EGB2060FFG EGB2063FFG EGB2070FFG EGB2080FFG EGB2090FFG EGB2100FFG EGB2125FFG
EGB3015FFG EGB3016FFG EGB3020FFG EGB3025FFG EGB3030FFG EGB3032FFG EGB3035FFG EGB3040FFG EGB3045FFG EGB3050FFG EGB3060FFG EGB3063FFG EGB3070FFG EGB3080FFG EGB3090FFG EGB3100FFG EGB3125FFG EGB3125KSG
EGB3020AFG EGB3025AFG EGB3032AFG EGB3040AFG EGB3050AFG EGB3063AFG EGB3080AFG EGB3100AFG EGB3125AFG
16-20 20-25 25-32 32-40 40-50 50-63 63-80 80-100 100-125
EGB4015FFG EGB4016FFG EGB4020FFG EGB4025FFG EGB4030FFG EGB4032FFG EGB4035FFG EGB4040FFG EGB4045FFG EGB4050FFG EGB4060FFG EGB4063FFG EGB4070FFG EGB4080FFG EGB4090FFG EGB4100FFG EGB4125FFG EGB4125KSG
EGB4020AFG EGB4025AFG EGB4032AFG EGB4040AFG EGB4063AFG EGB4080AFG EGB4100AFG EGB4125AFG
16-20 20-25 25-32 32-40 50-63 63-80 80-100 100-125
IEC/CE/UL/CSA 40/35
EGE2015FFG EGE2016FFG EGE2020FFG EGE2025FFG EGE2030FFG EGE2032FFG EGE2035FFG EGE2040FFG EGE2045FFG EGE2050FFG EGE2060FFG EGE2063FFG EGE2070FFG EGE2080FFG EGE2090FFG EGE2100FFG EGE2125FFG
EGE3015FFG EGE3016FFG EGE3020FFG EGE3025FFG EGE3030FFG EGE3032FFG EGE3035FFG EGE3040FFG EGE3045FFG EGE3050FFG EGE3060FFG EGE3063FFG EGE3070FFG EGE3080FFG EGE3090FFG EGE3100FFG EGE3125FFG EGE3125KSG
EGE3020AFG EGE3025AFG EGE3032AFG EGE3040AFG EGE3050AFG EGE3063AFG EGE3080AFG EGE3100AFG EGE3125AFG
16-20 20-25 25-32 32-40 40-50 50-63 63-80 80-100 100-125
EGE4015FFG EGE4016FFG EGE4020FFG EGE4025FFG EGE4030FFG EGE4032FFG EGE4035FFG EGE4040FFG EGE4045FFG EGE4050FFG EGE4060FFG EGE4063FFG EGE4070FFG EGE4080FFG EGE4090FFG EGE4100FFG EGE4125FFG EGE4125KSG
EGB4020AFG EGB4025AFG EGB4032AFG EGB4040AFG EGB4063AFG EGB4080AFG EGB4100AFG EGB4125AFG
16-20 20-25 25-32 32-40 50-63 63-80 80-100 100-125
IEC/CE/UL/CSA 70/65
EGS1015FFG EGS1016FFG EGS1020FFG EGS1025FFG EGS1030FFG EGS1032FFG EGS1035FFG EGS1040FFG EGS1045FFG EGS1050FFG EGS1060FFG EGS1063FFG EGS1070FFG EGS1080FFG EGS1090FFG EGS1100FFG EGS1125FFG
EGS2015FFG EGS2016FFG EGS2020FFG EGS2025FFG EGS2030FFG EGS2032FFG EGS2035FFG EGS2040FFG EGS2045FFG EGS2050FFG EGS2060FFG EGS2063FFG EGS2070FFG EGS2080FFG EGS2090FFG EGS2100FFG EGS2125FFG
EGS3015FFG EGS3016FFG EGS3020FFG EGS3025FFG EGS3030FFG EGS3032FFG EGS3035FFG EGS3040FFG EGS3045FFG EGS3050FFG EGS3060FFG EGS3063FFG EGS3070FFG EGS3080FFG EGS3090FFG EGS3100FFG EGS3125FFG EGS3125KSG
EGS3020AFG EGS3025AFG EGS3032AFG EGS3040AFG EGS3050AFG EGS3063AFG EGS3080AFG EGS3100AFG EGS3125AFG
16-20 20-25 25-32 32-40 40-50 50-63 63-80 80-100 100-125
EGS4015FFL EGS4016FFL EGS4020FFL EGS4025FFL EGS4030FFL EGS4032FFL EGS4035FFL EGS4040FFL EGS4045FFL EGS4050FFL EGS4060FFL EGS4063FFL EGS4070FFL EGS4080FFL EGS4090FFL EGS4100FFL EGS4125FFL EGS4125KSL
EGS4020AFG EGS4025AFG EGS4032AFG EGS4040AFG EGS4063AFG EGS4080AFG EGS4100AFG EGS4125AFG
16-20 20-25 25-32 32-40 50-63 63-80 80-100 100-125
EGH1015FFG EGH1016FFG EGH1020FFG EGH1025FFG EGH1030FFG EGH1032FFG EGH1035FFG EGH1040FFG EGH1045FFG EGH1050FFG EGH1060FFG EGH1063FFG EGH1070FFG EGH1080FFG EGH1090FFG EGH1100FFG EGH1125FFG
EGH2015FFG EGH2016FFG EGH2020FFG EGH2025FFG EGH2030FFG EGH2032FFG EGH2035FFG EGH2040FFG EGH2045FFG EGH2050FFG EGH2060FFG EGH2063FFG EGH2070FFG EGH2080FFG EGH2090FFG EGH2100FFG EGH2125FFG
EGH3015FFG EGH3016FFG EGH3020FFG EGH3025FFG EGH3030FFG EGH3032FFG EGH3035FFG EGH3040FFG EGH3045FFG EGH3050FFG EGH3060FFG EGH3063FFG EGH3070FFG EGH3080FFG EGH3090FFG EGH3100FFG EGH3125FFG EGH3125KSG
EGH3020AFG EGH3025AFG EGH3032AFG EGH3040AFG EGH3050AFG EGH3063AFG EGH3080AFG EGH3100AFG EGH3125AFG
16-20 20-25 25-32 32-40 40-50 50-63 63-80 80-100 100-125
EGH4015FFG EGH4016FFG EGH4020FFG EGH4025FFG EGH4030FFG EGH4032FFG EGH4035FFG EGH4040FFG EGH4045FFG EGH4050FFG EGH4060FFG EGH4063FFG EGH4070FFG EGH4080FFG EGH4090FFG EGH4100FFG EGH4125FFG EGH4125KSG
EGH4020AFG EGH4025AFG EGH4032AFG EGH4040AFG EGH4050AFG EGH4063AFG EGH4080AFG EGH4100AFG EGH4125AFG
16-20 20-25 25-32 32-40 40-50 50-63 63-80 80-100 100-125
Listed ratings
adjustable thermal listed.
Two-pole E-Frame breakers available
June 2001.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 15-125 Amperes
Selection Guide Ordering Information
Line Load Terminals E-Frame circuit breakers moulded case switches have line load terminals standard equipment.
Maximum Breaker Amperes Terminal Body Material Wire Type Metric Wire Range Wire Range Catalogue Number Package Terminals
Standard Cu/Al Pressure Type Terminals Steel Aluminium Aluminium Cu/Al Cu/Al 2.5-95 2.5-50 16-70 #14-3/0 #14-1/0 #6-3/0 3T125EF 3TA125EF 3TA150EF
Catalogue Number
Endcap
3T125EF
3TA125EF
3TA150EF
Insert collar enclosing conductor shown. Locate conductor tighten securely with screw washer. Caution: Collar must surround conductor.
Insert collar enclosing conductor centre extrusion. Tighten securely with screw washer.
EF3RTWK 3-Pole Metric, EF4RTWK 4-Pole Metric, EF3RTDK 3-Pole Imperial, EF4RTDK 4-Pole Imperial
Endcap kits used E-frame breaker line load connect similar electrical connections. Includes hardware. Terminal Shields terminal shield available line terminal areas 4-pole circuit breakers. Special terminal shields also available when electrical (solenoid) operator mounted circuit breaker. standard style number pole each terminal shield package priced each package. Special terminal shields packaged individually.
Number Poles Standard Package IP30 Protection
Control Wire Terminal
Interphase Barriers interphase barrier available extended insulation between circuit breaker poles. Specify quantity when ordering.
Package
Catalogue Number EFIPBK
with steel stainless steel terminals only.
Package Priced Individually
Base Mounting Hardware Base mounting hardware included with circuit breaker moulded case switch. (Included with breaker).
Rail Adapter Catalogue Number
Catalogue Number EFCWTK
Catalogue Numbers Priced Individually
4-Pole
EF34DIN
EFTS2K EFTS3K EFTS4K
Terminal Covers terminal cover available 3-pole circuit breakers only. conductor opening sizes available. Specify quantity (one circuit breaker) when ordering.
Conductor Opening Diameter (Inches) Catalogue Number
6.35 (0.25) 10.41 (0.41)
EFTC3K EFTC4K
Standard line load terminals.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 100-250 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Magnetic Range Rating 415/480 2-Pole Fixed Thermal Adjustable Magnetic 3-Pole Fixed Thermal Adjustable Magnetic Adjustable Thermal Adjustable Magnetic Thermal Range 4-Pole Fixed Thermal Adjustable Magnetic Adjustable Thermal Adjustable Magnetic Thermal Range
Complete Circuit Breaker Includes Frame, Trip Unit, Standard Terminals, Mounting Hardware
IEC/CE/UL/CSA 25/25
315-630 350-700 450-900 500-1000 625-1250 750-1500 800-1600 875-1750 1000-2000 1125-2250 1250-2500 1250-2500
JGE2070FAG JGE2090FAG JGE2100FAG JGE2125FAG JGE2150FAG JGE2175FAG JGE2200FAG JGE2225FAG JGE2250FAG
JGE3063FAG JGE3070FAG JGE3090FAG JGE3100FAG JGE3125FAG JGE3150FAG JGE3160FAG JGE3175FAG JGE3200FAG JGE3225FAG JGE3250FAG JGE3250KSG
JGE3063AAG JGE3100AAG JGE3125AAG JGE3160AAG JGE3200AAG JGE3250AAG
40-63 63-100 100-125 125-160 160-200 200-250
JGE4063FAG JGE4070FAG JGE4090FAG JGE4100FAG JGE4125FAG JGE4150FAG JGE4160FAG JGE4175FAG JGE4200FAG JGE4225FAG JGE4250FAG JGE4250KSG
JGE4063AAG JGE4100AAG JGE4125AAG JGE4160AAG JGE4200AAG JGE4250AAG
40-63 63-100 100-125 125-160 160-200 200-250
IEC/CE/UL/CSA 40/35
315-630 350-700 450-900 500-1000 625-1250 750-1500 800-1600 875-1750 1000-2000 1125-2250 1250-2500 1250-2500
JGS2070FAG JGS2090FAG JGS2100FAG JGS2125FAG JGS2150FAG JGS2175FAG JGS2200FAG JGS2225FAG JGS2250FAG
JGS3063FAG JGS3070FAG JGS3090FAG JGS3100FAG JGS3125FAG JGS3150FAG JGS3160FAG JGS3175FAG JGS3200FAG JGS3225FAG JGS3250FAG JGS3250KSG
JGS3063AAG JGS3100AAG JGS3125AAG JGS3160AAG JGS3200AAG JGS3250AAG
40-63 63-100 100-125 125-160 160-200 200-250
JGS4063FAG JGS4070FAG JGS4090FAG JGS4100FAG JGS4125FAG JGS4150FAG JGS4160FAG JGS4175FAG JGS4200FAG JGS4225FAG JGS4250FAG JGS4250KSG
JGS4063AAG JGS4100AAG JGS4125AAG JGS4160AAG JGS4200AAG JGS4250AAG
40-63 63-100 100-125 125-160 160-200 200-250
IEC/CE/UL/CSA 70/65
315-630 350-700 450-900 500-1000 625-1250 750-1500 800-1600 875-1750 1000-2000 1125-2250 1250-2500 1250-2500
JGH2070FAG JGH2090FAG JGH2100FAG JGH2125FAG JGH2150FAG JGH2175FAG JGH2200FAG JGH2225FAG JGH2250FAG
JGH3063FAG JGH3070FAG JGH3090FAG JGH3100FAG JGH3125FAG JGH3150FAG JGH3160FAG JGH3175FAG JGH3200FAG JGH3225FAG JGH3250FAG JGH3250KSG
JGH3063AAG JGH3100AAG JGH3125AAG JGH3160AAG JGH3200AAG JGH3250AAG
40-63 63-100 100-125 125-160 160-200 200-250
JGH4063FAG JGH4070FAG JGH4090FAG JGH4100FAG JGH4125FAG JGH4150FAG JGH4160FAG JGH4175FAG JGH4200FAG JGH4225FAG JGH4250FAG JGH4250KSG
JGH4063AAG JGH4100AAG JGH4125AAG JGH4160AAG JGH4200AAG JGH4250AAG
40-63 63-100 100-125 125-160 160-200 200-250
Components Frame
IEC/CE/UL/CSA 25/25
IEC/CE/UL/CSA 40/35
JGE2250NN
JGE3250NN
JGE4250NN
IEC/CE/UL/CSA 70/65
JGS2250NN
JGS3250NN
JGS4250NN
JGH2250NN
JGH3250NN
JGH4250NN
Trip Unit
315-630 350-700 450-900 500-1000 625-1250 750-1500 800-1600 875-1750 1000-2000 1125-2250 1250-2500 JT2063FA JT2070FA JT2090FA JT2100FA JT2125FA JT2150FA JT2160FA JT2175FA JT2200FA JT2225FA J2T250FA JT3063FA JT3070FA JT3090FA JT3100FA JT3125FA JT3150FA JT3160FA JT3175FA JT3200FA JT3225FA JT3250FA JT3063AA JT3100AA JT3125AA JT3160AA JT3200AA JT3250AA 40-63 63-100 100-125 125-160 160-200 200-250 JT4063FA JT4070FA JT4090FA JT4100FA JT4125FA JT4150FA JT4160FA JT4175FA JT4200FA JT4225FA JT4250FA JT4063AA JT4100AA JT4125AA JT4160AA JT4200AA JT4250AA 40-63 63-100 100-125 125-160 160-200 200-250
Change digit adjustable
0-60% neutral protection, 0-100% neutral protection.
IEC-EN 60947-2 only. 3-pole MCS.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size J250, 63-250 Amperes
Selection Guide Ordering Information
Line Load Terminals J250-Frame circuit breakers include terminals, T250FJ standard. When optional copper Cu/1919Al terminals required, order catalogue number.
Maximum Breaker Amperes Terminal Body Material Wire Type Metric Wire Range Wire Range/ Catalogue Number Conductors Number
Standard Pressure Type Terminals Stainless Steel Aluminium Copper Cu/Al Cu/Al 25-185 25-185 25-185 4-350/(1) 4-350/(1) 4-350/(1) T250FJ TA250FJ TC250FJ
Optional Copper Cu/Al Pressure Type Terminals
Catalogue Number
T250FJ
TA250FJ
TC250FJ
Endcap
Control Wire Terminal
Base Mounting Hardware Base mounting hardware included with circuit breaker moulded case switch. (Included with breaker). Terminal Shields IP30
Location Number Poles Catalogue Number Package
Line Load
Endcap kits used J250 Frame breaker line load connect similar electrical connections. Includes hardware.
Catalogue Number
Number Catalogue Number Poles Metric
with aluminium copper terminals only.
Package Priced Individually
FJTS3K FJTS4K
Interphase Barriers
Package Number Poles Catalogue Number
Catalogue Number FJCWTK
FJIPBK FJIPBK4
Imperial
FJ3RTWK FJ4RTWK
FJ3RTDK FJ4RTDK
Individually packed. Standard line load terminals.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 63-400 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Number Poles Thermal Range Magnetic Range Standard Interrupting Capacity Catalogue Number Max. Frame Factory Only Assembled Circuit Breaker Consisting Frame, Trip Unit, Terminals Mounting Hardware High Interrupting Capacity Catalogue Number Max. Frame Factory Only Assembled Circuit Breaker Consisting Frame, Trip Unit, Terminals Mounting Hardware Ultra-High Interrupting Capacity Catalogue Number Max. Frame Factory Only Assembled Circuit Breaker Consisting Frame, Trip Unit, Terminals Mounting Hardware Thermal Magnetic Trip Unit Only with Standard High UltraHigh Interrupting Frame Adjustable Thermal Adjustable Magnetic Standard Terminals Only Catalogue Number Metric Mounting Hardware Catalogue Number
Adjustable Thermal Magnetic Circuit Breakers with Interchangeable Trip Units
3-Pole 160-200 200-250 250-315 315-400 160-200 200-250 250-315 315-400 2-Pole 3-Pole 4-Pole 1000-2000 1250-2500 1575-3150 2000-4000 1000-2000 1250-2500 1575-3150 2000-4000 2-Pole 160-200 200-250 250-315 315-400 160-200 200-250 250-315 315-400 160-200 200-250 250-315 315-400 250-315 315-400 1000-2000 1250-2500 1575-3150 2000-4000 1000-2000 1250-2500 1575-3150 2000-4000 1000-2000 1250-2500 1575-3150 2000-4000 1575-3150 2000-4000
Type Type Type
KWC2400F KT2200TA KT2250TA KT2315TA KT2400TA KWC3400F KT3200TA KT3250TA KT3315TA KT3400TA KWC4400F KT4200TA KT4250TA KT4315TA KT4400TA KT4315TEA KT4400TEA TA300KM TA300KM TA350KM TA350KM TA300KM TA300KM TA350KM TA350KM TA300KM TA300KM TA350KM TA350KM TA350KM TA350KM TA350KM TA350KM TA350KM TA350KM TA350KM TA350KM TA350KM TA350KM BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M
KW2200 KW2250 KW2315 KW2400 KW3200 KW3250 KW3315 KW3400 KW4200 KW4250 KW4315 KW4400 KW4315E KW4400E
Type ELKW Max. VAC)
KW2400F
HKW2200 HKW2250 HKW2315 HKW2400 HKW3200 HKW3250 HKW3315 HKW3400 HKW4200 HKW4250 HKW4315 HKW4400 HKW4315E HKW4400E
Type ELHKW Max. VAC)
HKW240F
KWC2200 KWC2250 KWC2315 KWC2400
3-Pole
KW3400F
HKW3400F KWC3200 KWC3250 KWC3315 KWC3400 HKW4400F KWC4200 KWC4250 KWC4315 KWC4400 KWC4315E KWC4400E
4-Pole
KW4400F
Adjustable Thermal Magnetic Earth Leakage Circuit Breakers with Line Load Terminals Included
Type ELKWC Max. VAC)
ELKW3200 ELKW3250 ELKW3315 ELKW3400 ELKW4200 ELKW4250 ELKW4315 ELKW4400
Type Max. VAC)
ELHKW3200 ELHKW3250 ELHKW3315 ELHKW3400 ELHKW4200 ELHKW4250 ELHKW4315 ELHKW4400
Type Max. VAC)
ELKWC3200 ELKWC3250 ELKWC3315 ELKWC3400 ELKWC4200 ELKWC4250 ELKWC4315 ELKWC4400
4-Pole
Moulded Case Switches Only without Line Load Terminals
TA350KM TA350KM TA350KM BMH3M BMH3M BMH3M
KW2400KW KW3400KW KW4400KW
HKW2400KW HKW3400KW HKW4400KW
Electronic Circuit Breakers With Interchangeable Type Digitrip Trip Units Order Individual Components: Breaker Frame, Trip Unit, Rating Plug, Terminals, Mounting Hardware
Maximum Continuous Ampere Rating 40°C Number Poles Circuit Breaker Frame Only Catalogue Number Standard Interrupting Capacity High Interrupting Capacity Ultra-High Interrupting Capacity Digitrip Trip Unit Only Less Rating Plug Catalogue Number Adjustable Long Delay Pickup Adjustable Rating Plug) Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) Adjustable Short Delay Time (Flat Response) Adjustable Instantaneous Pickup Setting Short Delay Time Instantaneous Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) LSIG Digitrip Only Rating Plug Order Individual Component Fixed Rating Plug Adjustable Rating Plug Standard Terminals Only Catalogue Number Metric Mounting Hardware Catalogue Number
Max. Type Type Type
Ampere Rating
Catalogue Ampere Number Rating Catalogue Number
3-Pole
KW3400F
HKW3400F KWC3400F
KES3125LS KES3125LSI
KES3125LSG
KES3125LSIG
KW3400F
HKW3400F KWC3400F
KES3250LS KES3250LSI
KES3250LSG
KES3250LSIG
KW3400F
HKW3400F KWC3400F
KES3400LS KES3400LSI
KES3400LSG
KES3400LSIG
1KES063T 1KES070T 1KES090T 1KES100T 1KES125T 2KES125T 2KES160T 2KES200T 2KES225T 2KES250T 4KES200T 4KES225T 4KES250T 4KES315T 4KES400T
Adjustable Settings are: 63/80/ 100/125 A1KES125T2 Adjustable Settings are: 125/160/ 225/250 A2KES250T2 Adjustable Settings are: 200/250/ 315/400 A4KES400T2
TA300KM TA300KM TA300KM TA300KM TA300KM TA300KM TA300KM TA300KM TA300KM TA300KM TA300KM TA300KM TA300KM TA350KM TA350KM
BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M BMH3M
Individually packed.
Special rating available.
Order description.
protected neutral left pole application only.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 63-400 Amperes
Selection Guide Ordering Information
Line Load Terminals K-Frame circuit breakers include Cu/Al terminals standard. When optional copper Cu/1919Al terminals required, order catalogue number.
Maximum Breaker Amperes Terminal Body Material Wire Type Metric Wire Range Wire Range/ Catalogue Number Conductors Number
Standard Pressure Type Terminals Aluminium Aluminium Copper Copper Aluminium Cu/Al Cu/Al Cu/Al 35-185 120-240 35-185 120-240 95-120 3-350/(1) 250-500/(1) 3-350/(1) 250-500/(1) 3/0-250/(2) TA300KM TA350KM T300K T300K 2TA400K 2-Pole 3TA400K 3-Pole 4TA400K 4-Pole 2T400K 2-Pole 3T400K 3-Pole 4T400K 4-Pole 2TA401K 2-Pole 3TA401K 3-Pole 4TA401K 4-Pole
Optional Copper Cu/Al Pressure Type Terminals
Aluminium
95-120
3/0-250/(2)
Aluminium
Cu/Al
70-240 70-240 70-240
2/0-250/(2) 2/0-500/(1)
Catalogue Number
TA300KM, TA300K, T300K
TA350KM, TA350K, T350K
TA400K, T400K
TA401K
Endcap
Control Wire Terminal
Handle Extension included with breaker. Must purchased separately.
Packaged Individually
Catalogue Number HEX3
Terminal Shields
Location
Endcap kits used K-Frame breaker line load connect similar electrical connections. Includes hardware.
Catalogue Number
Metric Imperial
with aluminium copper terminals only.
Package Priced Individually
Number Poles
Catalogue Number Package
Line Load Interphase Barriers
Package
TS33LN TS34LN TS33LD
Catalogue Number KCWTK
KPEKM3
KPEK3
Base Mounting Hardware Base mounting hardware included with circuit breaker moulded case switch.
Number Description Poles Type Mounting Catalogue Number
Catalogue Number IPB3
Metric Thread M6-0.7 Individual 4218B80G14 Pan-Head screws Lockwashers 0.250-20 Inch Pan-Head Steel Screws Lockwashers Individual 4218B80G14
Imperial Thread
Metric hardware. Imperial hardware. Individually packed. TA400K, T400K, TA401K terminal kits contain terminal each pole terminal cover. Standard terminal.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 315-800 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Number Poles Standard Interrupting Capacity Catalogue Number Max. Factory Assembled Circuit Breaker Consisting Frame, Trip Unit, Terminals Frame Only High Interrupting Capacity Catalogue Number Max. Factory Assembled Circuit Breaker Consisting Frame, Trip Unit, Terminals Frame Only Ultra-High Interrupting Capacity Thermal Catalogue Number Magnetic Trip Unit Only Max. with Standard High Frame Only Ultra-High Factory Assembled Interrupting Circuit Breaker Frame Consisting Adjustable Frame, Trip Unit, Thermal Terminals Adjustable Magnetic Standard Terminals Only Catalogue Number Metric Mounting Hardware Catalogue Number
Adjustable Thermal Magnetic Circuit Breakers with Interchangeable Trip Units
2-Pole 3-Pole 4-Pole 3-Pole 4-Pole 3-Pole 2-Pole
Type Type Type
3-Pole
4-Pole
LW2315 LW2400 LW2500 LW2630 LW3315 LW3400 LW3500 LW3630 LW4315 LW4400 LW4500 LW4630 LW4500 LW4630
LW2630F
LW3630F
LW4630F
HLW2315 HLW2400 HLW2500 HLW2630 HLW3315 HLW3400 HLW3500 HLW3630 HLW4315 HLW4400 HLW4500 HLW4630 HLW4500E HLW4630E
HLW2630F
HLW3630F
HLW4630F
LWC2315 LWC2400 LWC2500 LWC2630 LWC3315 LWC3400 LWC3500 LWC3630 LWC4315 LWC4400 LWC4500 LWC4630 LWC4500E LWC4630E
LWC2630F
LWC3630F
LWC4630F
LT2315TA LT2400TA LT2500TA LT2630TA LT3315TA LT3400TA LT3500TA LT3630TA LT4315TA LT4400TA LT4500TA LT4630TA LT4500TA LT4630TAE
TA602LDM TA602LDM TA602LDM TA603LDKM TA602LDM TA602LDM TA602LDM TA603LDKM TA602LDM TA602LDM TA602LDM TA603LDKM TA602LDM TA603LDKM
BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M
Thermal Magnetic Fixed Thermal Circuit Breakers with Noninterchangeable Trip Units Extension
Types Max. VAC, VAC) LW3700W LW3800W BMH4M BMH4M
Moulded Case Switches Only without Line Load Terminals
Type (690 Max.) LW2630KW LW3630WK LW4630WK LW3800WK LW4800WK Type (690 Max.) HLW2630KW HLW3630WK HLW4630WK TA603LDKM TA603LDKM TA603LDKM BMH4M BMH4M BMH4M BMH4M BMH4M
Electronic Circuit Breakers With Interchangeable Type Digitrip Trip Units Order Individual Components: Breaker Frame, Trip Unit, Rating Plug, Terminals, Mounting Hardware
Maximum Continuous Ampere Rating 40°C Number Poles Circuit Breaker Frame Only Catalogue Number Standard Interrupting Capacity Max. Type Type Type High Interrupting Capacity Ultra-High Interrupting Capacity Digitrip Trip Unit Only Less Rating Plug Catalogue Number Adjustable Long Delay Pickup Adjustable Rating Plug) Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) Adjustable Short Delay Time (Flat Response) Adjustable Instantaneous Pickup Setting Short Delay Time Instantaneous Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) LSIG Digitrip Only Rating Plug Order Individual Component Fixed Rating Plug Adjustable Rating Plug Standard Terminals Only Catalogue Number Metric Mounting Hardware Catalogue Number
Ampere Catalogue Ampere Rating Number Rating Catalogue Number
3-Pole
LW3630F
HLW3630F
LWC3630F LES3630LS LES3630LSI
LES3630LSG LES3630LSIG
4-Pole
LW4630F
HLW4630F
LWC4630F LES4630LS LES6430LSI
LES4630LSG LES4630LSIG
6LES315T 6LES350T 6LES400T 6LES500T 6LES630T 6LES315T 6LES350T 6LES400T 6LES500T 6LES630T
Adjustable Settings are: 315/400/ 500/630 A6LES630T2 Adjustable Settings are: 315/400/ 500/630 A6LES630T2
TA602LDM TA602LDM TA602LDM TA603LDKM TA603LDKM TA602LDM TA602LDM TA602LDM TA603LDKM TA603LDKM
BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M BMH4M
Electronic Circuit Breakers Includes Circuit Breaker Frame, Digitrip Electronic Trip Units with Noninterchangeable Adjustable Rating Plug Extension 3-Pole LW3800T33W Adjustable
LW3800T35W LW3800T35XW Settings are: 400/500/ 630/800 A8LES800T1
BMH4M BMH4M BMH4M BMH4M
4-Pole LW4800T33W Individually packed. Special rating available.
Order description. 2TA603KM, 3TA603LDKM 4TA603LDKM terminal kits contain terminal each pole terminal cover.
protected neutral left pole Ampere rating established rating plug. application only. 3-pole trip units 3-pole frames only.
Trip unit includes unprotected left neutral
pole. 100% protected left pole neutral catalogue number, i.e., LES4630LSP.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 315-800 Amperes
Selection Guide Ordering Information
Line Load Terminals L-Frame circuit breakers include Cu/Al terminals standard equipment. When optional copper terminals required, order catalogue number. ampere L-Frame circuit breakers include extensions only.
Maximum Breaker Amperes
Terminal Body Material
Wire Type
Metric Wire Range
Wire Range Conductors
Catalogue Number
Standard Cu/Al Pressure Type Terminals Aluminium Aluminium Aluminium Aluminium Cu/AI Cu/AI Cu/AI Cu/AI 120-300 25-95 120-150 185-240 4/0-600 4-4/0 250-350 400-500 3TA401LDKM 3-Pole 4TA401LDKM 4-Pole TA450LDM TA602LDM 3TA603LDKM 3-Pole 4TA603LDKM 4-Pole T602LDM
Optional Copper Pressure Type Terminals Copper Copper 120-150 250-350
TA401LD TA603LD Terminal (Step-Type Terminal Requires Terminal Cover Warning Label. Inset.)
Pan-Head Screws Lockwashers
TA450LD, TA602LD, T602LD Terminal Pan-Head Screws Lockwashers (Installed before Cable Clamping Screws)
Terminal Cover
Warning Label Retainer Screws Circuit Breaker Line Terminal Cover
Terminal Shields Terminal shields provide protection against accidental contact with live line side terminations. Terminal shields fabricated from high dielectric insulating material fasten over front terminal access openings. Small openings shields provide limited access terminals tightening connectors. (Field installation only.)
Package
Base Mounting Hardware Base mounting hardware included with circuit breaker moulded case switch.
Number Poles Description Type Mounting Style Number
between terminals. (Field installation only.) package.
Package
Catalogue Number IPB4
Endcap
Metric Thread 0.250-20 Individual 5103A09G01 Imperial Thread 0.250-20 Individual 21C6782G05 Inch Filister-Head Steel Screws Lockwashers Flat Washers
Style Number 314C420G01
Handle Extension included with breaker. Must purchased separately.
Packaged Individually
Catalogue Number
Metric Imperial
KPEKM4
KPEK4
Catalogue Number HEX4
Keeper required L-Frame. Terminal threaded.
Individually packed. Terminal kits contain terminal each
pole terminal cover.
Interphase Barriers interphase barriers provide additional electrical clearance between circuit breaker poles special termination applications. barriers high dielectric insulating plates that installed moulded slots
Endcap kits used L-Frame breaker line load connect similar electrical connections. Includes hardware. Catalogue Number
Metric Imperial
KPEKM4
KPEK4
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 400-1250 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Number Poles Circuit Breaker Frame Including Digitrip Electronic Trip Unit Less Rating Plugs Terminals Order Individual Component Catalogue Number Adjustable Long Delay Pickup Adjustable Rating Plug) Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) Adjustable Short Delay Time (Flat Response) Adjustable Instantaneous Pickup Setting Short Delay Time Instantaneous -Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) LSIG Digitrip Interchangeable Rating Plugs Order Individual Component Fixed Rating Plug Ampere Rating Catalogue Number Adjustable Rating Plug Ampere Rating Catalogue Number
Short Time Range Short Time Delay 0-300 Ground Fault Pickup 200-1200A Ground Fault Delay 0-500 Type Standard Interrupting Capacity Max. VAC, 2-Pole NW2800T33W NW2800T32W NW2800T35W
0-300 200-1200A 0-500 NW2800T36W 1000 1200 1250 1000 1200 1250 1000 1200 1250 8NES400T 8NES450T 8NES500T 8NES550T 8NES600T 8NES630T 8NES700T 8NES800T 8NES400T 8NES450T 8NES500T 8NES550T 8NES600T 8NES630T 8NES700T 8NES800T 8NES400T 8NES450T 8NES500T 8NES550T 8NES600T 8NES630T 8NES700T 8NES800T 12NES600T 12NES630T 12NES700T 12NES800T 12NES900T 12NES1000T 12NES1200T 12NES1250T 12NES600T 12NES630T 12NES700T 12NES800T 12NES900T 12NES1000T 12NES1200T 12NES1250T 12NES600T 12NES630T 12NES700T 12NES800T 12NES900T 12NES1000T 12NES1200T 12NES1250T Adjustable Settings Are: 400/500/630/800 8NES800T2
3-Pole
NW3800T33W
NW3800T32W
NW3800T35W
NW3800T36W
400/500/630/800 8NES800T2
4-Pole
NW4800T33W
NW4800T32W
400/500/630/800 8NES800T2
1250
2-Pole
NW2125T33W
NW2125T32W
NW2125T35W
NW2125T36W
630/800/1000/1250 A12NES1250T2
3-Pole
NW3125T33W
NW3125T32W
NW3125T35W
NW3125T36W
630/800/1000/1250 A12NES1250T2
4-Pole
NW4125T33W
NW4125T32W
630/800/1000/1250 A12NES1250T2
Moulded Case Switches
Ampere Rating Number Poles Max. Catalogue Number
1250 only. Special rating available. Order
description.
1250
2-pole applications, outer poles
3-pole moulded case switch.
3-Pole 4-Pole 3-Pole 4-Pole 3-Pole 4-Pole 3-Pole 4-Pole
NW3800WK NW4800WK NW3125WK NW4125WK HNW3800WK HNW4800WK HNW3125WK HNW4125WK
Only without Line Load Only without Line Load Only without Line Load Only without Line Load
Order rating plug terminals separately.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 400-1250 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Number Poles Circuit Breaker Frame Including Digitrip Electronic Trip Unit Less Rating Plugs Terminals Order Individual Component Catalogue Number Adjustable Long Delay Pickup Adjustable Rating Plug) Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) Adjustable Short Delay Time (Flat Response) Adjustable Instantaneous Pickup Setting Short Delay Time Instantaneous Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) Digitrip Interchangeable Rating Plugs Order Individual Component Fixed Rating Plug Ampere Rating Catalogue Number Adjustable Rating Plug Ampere Rating Catalogue Number
Short Time Range Short Time Delay Ground Fault Pickup Ground Fault Delay 2-Pole
LSIG
HNW2800T33W
0-300 HNW2800T32W
200-1200A 0-500 HNW2800T35W
0-300 200-1200A 0-500 HNW2800T36W 8NES400T 8NES450T 8NES500T 8NES550T 8NES600T 8NES630T 8NES700T 8NES800T 8NES400T 8NES450T 8NES500T 8NES550T 8NES600T 8NES630T 8NES700T 8NES800T 8NES400T 8NES450T 8NES500T 8NES550T 8NES600T 8NES630T 8NES700T 8NES800T 12NES600T 12NES630T 12NES700T 12NES800T 12NES900T 12NES1000T 12NES1200T 12NES1250T 12NES600T 12NES630T 12NES700T 12NES800T 12NES900T 12NES1000T 12NES1200T 12NES1250T 12NES600T 12NES630T 12NES700T 12NES800T 12NES900T 12NES1000T 12NES1200T 12NES1250T 630/800/1000/1250 A12NES1250T2 630/800/1000/1250 A12NES1250T2 630/800/1000/1250 A12NES1250T2 400/500/630/800 8NES800T2 400/500/630/800 8NES800T2 Adjustable Settings Are: 400/500/630/800 8NES800T2
Type Standard Interrupting Capacity Max. VAC,
3-Pole
HNW3800T33W
HNW3800T32W
HNW3800T35W
HNW3800T36W
4-Pole
HNW4800T33W
HNW4800T32W
1250
2-Pole
HNW2125T33W
HNW2125T32W
HNW2125T35W
HNW2125T36W
1000 1200 1250
3-Pole
HNW3125T33W
HNW3125T32W
HNW3125T35W
HNW3125T36W
1000 1200 1250
4-Pole
HNW4125T33W
HNW4125T32W
1000 1200 1250
only. Special rating available.
Order description.
Order rating plug terminals separately.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 400-1250 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Number Poles Circuit Breaker Frame Including Digitrip Electronic Trip Unit Less Rating Plugs Terminals Order Individual Component Catalogue Number Adjustable Long Delay Pickup Adjustable Rating Plug) Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) Adjustable Short Delay Time (Flat Response) Adjustable Instantaneous Pickup Setting Short Delay Time Instantaneous Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) Digitrip Interchangeable Rating Plugs Order Individual Component Fixed Rating Plug Ampere Rating Catalogue Number Adjustable Rating Plug Ampere Rating Catalogue Number
Short Time Range Short Time Delay Ground Fault Pickup Ground Fault Delay 2-Pole
LSIG
NWC2800T33W
0-300 NWC2800T32W
200-1200A 0-500 NWC2800T35W
0-300 200-1200A 0-500 NWC2800T36W 8NES400T 8NES450T 8NES500T 8NES550T 8NES600T 8NES630T 8NES700T 8NES800T 8NES400T 8NES450T 8NES500T 8NES550T 8NES600T 8NES630T 8NES700T 8NES800T 8NES400T 8NES450T 8NES500T 8NES550T 8NES600T 8NES630T 8NES700T 8NES800T 12NES600T 12NES630T 12NES700T 12NES800T 12NES900T 12NES1000T 12NES1200T 12NES1250T 12NES600T 12NES630T 12NES700T 12NES800T 12NES900T 12NES1000T 12NES1200T 12NES1250T 12NES600T 12NES630T 12NES700T 12NES800T 12NES900T 12NES1000T 12NES1200T 12NES1250T 630/800/1000/1250 A12NES1250T2 630/800/1000/1250 A12NES1250T2 630/800/1000/1250 A12NES1250T2 400/500/630/800 8NES800T2 400/500/630/800 8NES800T2 Adjustable Settings Are: 400/500/630/800 8NES800T2
Type Standard Interrupting Capacity Max. VAC,
3-Pole
NWC3800T33W
NWC3800T32W
NWC3800T35W
NWC3800T36W
4-Pole
NWC4800T33W
NWC4800T32W
1250
2-Pole
NWC2125T33W
NWC2125T32W
NWC2125T35W
NWC2125T36W
1000 1200 1250
3-Pole
NWC3125T33W
NWC3125T32W
NWC3125T35W
NWC3125T36W
1000 1200 1250
4-Pole
NWC4125T33W
NWC4125T32W
1000 1200 1250
only. Special rating available.
Order description.
Order rating plug terminals separately.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 400-1250 Amperes
Selection Guide Ordering Information
Line Load Terminals N-Frame circuit breakers include Cu/Al terminals standard. When optional copper Cu/Al terminals required, order catalogue number.
Maximum Breaker Amperes Terminal Body Material Wire Type Metric Wire Range Wire Number Conductors Catalogue Number
Standard Cu/Al Pressure-Type Terminals 1250 1250 Aluminium Copper Cu/Al Copper 120-300 95-185 4/0-500 3/0-400 TA1200NB3M T1200NB3M Optional Copper Cu/Al Pressure Type Terminals
Base Mounting Hardware Base mounting hardware included with circuit breaker moulded case switch. Imperial Thread
Number Poles Description Catalogue Number
Keeper required N-Frame. Terminals threaded. Handle Extension Included with breaker. Additional handle extensions available.
Single Handle Extension
0.3125-18 1.25 Inch 4-pole Pan-Head Steel Screws Lock Washers
BMH5M
Interphase Barriers interphase barriers provide additional electrical clearance between circuit breaker poles special termination applications. Barriers high dielectric insulating plates that installed Moulded slots between terminals. (Field installation only.)
Interphase Barriers
Catalogue Number HEX5 Catalogue Number IPB5
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 800-2500 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Number Poles Circuit Breaker Frame Including Digitrip Electronic Trip Unit Less Rating Plugs Terminals Order Individual Component Catalogue Number Adjustable Long Delay Pickup Adjustable Rating Plug) Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) Adjustable Short Delay Time (Flat Response) Adjustable Instantaneous Pickup Setting Short Delay Time Instantaneous Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) Digitrip Interchangeable Rating Plugs Order Individual Component Fixed Rating Plug Ampere Rating Catalogue Number Adjustable Rating Plug Ampere Rating Catalogue Number
Short Time Range Short Time Delay Ground Fault Pickup Ground Fault Delay 1600 3-Pole
LSIG
RW316T33W
0-300 RW316T32W
200-1200A 0-500 RW316T35W
0-300 200-1200A 0-500 RW316T36W 1000 1200 1250 1400 1500 1600 16RES08T 16RES10T 16RES12T 16RES125T 16RES14T 16RES15T 16RES16T 20RES10T 20RES12T A20RES125T A20RES14T A20RES16T A20RES20T 25RES12T 25RES125T A25RES16T A25RES20T A25RES25T 16RES08T 16RES10T 16RES12T 16RES125T 16RES14T 16RES15T 16RES16T 20RES10T 20RES12T A20RES125T A20RES14T A20RES16T A20RES20T 25RES12T 25RES125T A25RES16T A25RES20T A25RES25T 1000/1200/1600/2000 A20RES20T1 1000/1250/1600/2000 A20RES20T2 Adjustable Settings Are: 800/1000/1200/1600 A16RES16T1 800/1000/1250/1600 A16RES16T2 1000/1200/1600/2000 A20RES20T1 1000/1250/1600/2000 A20RES20T2
Type with Digitrip Standard Interrupting Capacity Max. VAC,
2000
RW320T33W
RW320T32W
RW320T35W
RW320T36W
1000 1200 1250 1400 1600 2000
2500
RW325T33W
RW325T32W
RW325T35W
RW325T36W
1200 1250 1600 2000 2500 1000 1200 1250 1400 1500 1600
1200/1600/2000/2500 A25RES25T1 1250/1600/2000/2500 A25RES25T2 800/1000/1200/1600 A16RES16T1 800/1000/1250/1600 A16RES16T2
1600
4-Pole
RW416T33W
RW416T32W
2000
RW420T33W
RW420T32W
1000 1200 1250 1400 1600 2000
2500
RW425T33W
RW425T32W
1200 1250 1600 2000 2500
1200/1600/2000/2500 A25RES25T1 1250/1600/2000/2500 A25RES25T2
application, 2000A frame. Special rating available.
Order description. Unprotected left pole neutral. catalogue number 100% protected left pole neutral, protected, i.e., "RW416T33PW", "RW416T33EW".
Ground fault equipped trip units available
with remote indicating panel. catalogue number, i.e., "RW316T35RW". Order rating plug terminals separately. Mounting hardware included.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 800-2500 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Number Poles Circuit Breaker Frame Including Digitrip Electronic Trip Unit Less Rating Plugs Terminals Order Individual Component Catalogue Number Adjustable Long Delay Pickup Adjustable Rating Plug) Adjustable Short Delay Pickup with Fixed Short Delay Time (I2t Response) Adjustable Short Delay Time (Flat Response) Adjustable Instantaneous Pickup Setting Short Delay Time Instantaneous Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response) Digitrip Interchangeable Rating Plugs Order Individual Component Fixed Rating Plug Ampere Rating Catalogue Number Adjustable Rating Plug Ampere Rating Catalogue Number
Short Time Range Short Time Delay Ground Fault Pickup Ground Fault Delay 1600 3-Pole
LSIG
RWC316T33W
0-300 RWC316T32W
200-1200A 0-500 RWC316T35W
0-300 200-1200A 0-500 RWC316T36W 1000 1200 1250 1400 1500 1600 16RES08T 16RES10T 16RES12T 16RES125T 16RES14T 16RES15T 16RES16T 20RES10T 20RES12T A20RES125T A20RES14T A20RES16T A20RES20T 16RES08T 16RES10T 16RES12T 16RES125T 16RES14T 16RES15T 16RES16T 20RES10T 20RES12T A20RES125T A20RES14T A20RES16T A20RES20T 1000/1200/1600/2000 A20RES20T1 1000/1250/1600/2000 A20RES20T2 Adjustable Settings Are: 800/1000/1200/1600 A16RES16T1 800/1000/1250/1600 A16RES16T2
Type with Digitrip High Interrupting Capacity Max. VAC,
2000
RWC320T33W
RWC320T32W
RWC320T35W
RWC320T36W
1000 1200 1250 1400 1600 2000
1000/1200/1600/2000 A20RES20T1 1000/1250/1600/2000 A20RES20T2
1600
4-Pole
RWC416T33W
RWC416T32W
1000 1200 1250 1400 1500 1600
800/1000/1200/1600 A16RES16T1 800/1000/1250/1600 A16RES16T2
2000
RWC420T33W
RWC420T32W
1000 1200 1250 1400 1600 2000
Moulded Case Switches
Ampere Rating Number Poles Catalogue Number
1600A 2000A 1600A 2000A
3-Pole 4-Pole
RW316WK RW320WK RW416WK RW420WK
application, 2000A frame. Special rating available.
Order description. Unprotected left pole neutral. catalogue number 100% protected left pole neutral, protected, i.e., "RW416T33PW", "RW416T33EW".
Ground fault equipped trip units available
with remote indicating panel. catalogue number, i.e., "RW316T35RW". Order rating plug terminals separately. Mounting hardware included.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 800-1250 Amperes
Selection Guide Ordering Information
Maximum Continuous Ampere Rating 40°C Number Poles Circuit Breaker Frame Including Digitrip Electronic Trip Unit Less Rating Plugs Terminals Order Individual Component Catalogue Number Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time Adjustable Short Delay Pickup with Adjustable Short Delay Time Flat Response) Adjustable Instantaneous Pickup Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay Flat Response) Digitrip Interchangeable Rating Plug Order Individual Component Fixed Rating Plug Ampere Rating LSIG Catalogue Number
Long Delay Pickup Long Delay Time Short Time Range Short Time Delay Instantaneous Ground Fault Pickup Ground Fault Delay 1600 3-Pole
0.5-1.0 2-24 Seconds RW316T61W
0.5-1.0 2-24 Seconds 100-500 RW316T63W
0.5-1.0 2-24 Seconds 100-500 RW316T62W
0.5-1.0 2-24 Seconds 0.25-1.0 100-500 RW316T64W
0.5-1.0 2-24 Seconds 100-500 0.25-1.0 100-500 RW316T65W
0.5-1.0 2-24 Seconds 100-500 0.25-1.0 100-500 RW316T66W 1000 1200 1250 1600 1000 1200 1250 1600 2000 1600 2000 2500 1000 1200 1250 1600 1000 1200 1250 1600 2000 1000 1200 1250 1600 1000 1200 1250 1600 2000 1600 2000 2500 1000 1200 1250 1600 1000 1200 1250 1600 2000 RP6R16A080 RP6R16A100 RP6R16A120 RP6R16A125 RP6R16A160 RP6R20A100 RP6R20A120 RP6R20A125 RP6R20A160 RP6R20A200 RP6R25A160 RP6R25A200 RP6R25A250 RP6R16A080 RP6R16A100 RP6R16A120 RP6R16A125 RP6R16A160 RP6R20A100 RP6R20A120 RP6R20A125 RP6R20A160 RP6R20A200 RP6R16A080 RP6R16A100 RP6R16A120 RP6R16A125 RP6R16A160 RP6R20A100 RP6R20A120 RP6R20A125 RP6R20A160 RP6R20A200 RP6R25A160 RP6R25A200 RP6R25A250 RP6R16A080 RP6R16A100 RP6R16A120 RP6R16A125 RP6R16A160 RP6R20A100 RP6R20A120 RP6R20A125 RP6R20A160 RP6R20A200
Type with Digitrip Standard Interrupting Capacity Max. VAC,
2000
RW320T61W
RW320T63W
RW320T62W
RW320T64W
RW320T65W
RW320T66W
2500
RW325T61W
RW325T63W
RW325T62W
RW325T64W
RW325T65W
RW325T66W
Type with Digitrip High Interrupting Capacity Max. VAC, 1600 3-Pole RWC316T61W RWC316T63W RWC316T62W RWC316T64W RWC316T65W RWC316T66W
2000
RWC320T61W
RWC320T63W
RWC320T62W
RWC320T64W
RWC320T65W
RWC320T66W
Type with Digitrip Standard Interrupting Capacity Max. VAC, 1600 3-Pole RW316T91W RW316T93W RW316T92W RW316T94W RW316T95W RW316T96W
2000
RW320T91W
RW320T93W
RW320T92W
RW320T94W
RW320T95W
RW320T96W
2500
RW325T91W
RW325T93W
RW325T92W
RW325T94W
RW325T95W
RW325T96W
Type with Digitrip High Interrupting Capacity Max. VAC, 1600 3-Pole RWC316T91W RWC316T93W RWC316T92W RWC316T94W RWC316T95W RWC316T96W
2000
RWC320T91W
RWC320T93W
RWC320T92W
RWC320T94W
RWC320T95W
RWC320T96W
Special rating available.
Order description.
Order rating plug terminals separately.
Mounting hardware included.
exceed 1200A ground fault pick-up.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Size 800-2500 Amperes
Selection Guide Ordering Information
Line Load Terminals R-Frame circuit breakers have Cu/Al terminals standard copper only terminals option. Specify factory installation required.
Maximum Breaker Amperes Terminal Body Material Wire Type Hardware AWG/kmil Wire Range/Number Conductors Metric Wire Range Catalogue Number
Wire Terminals 1600 1600 2000 Rear Connectors 2000 2000 2500 Copper Copper Copper English English English B2016RD B2016RDL B2500RD Aluminium Copper Aluminium Cu/Al Cu/Al English English English 500-1000 1-600 2-600 300-500 50-300 35-300 TA1600RD T1600RD TA2000RD
Rear Connector Exploded View
Conductor (Viewed from Rear Circuit Breaker Away Clarity) Conductor (Viewed from Front Circuit Breaker)
TA2000RD
Securing Hardware Only Terminal Catalogue Number T1600RD (For 1600A Frame Only) Al/Cu Terminal Catalogue Number TA1600RD (For 1600A Frame Only)
Breaker Line/Load Conductors
Securing Hardware Rear Connector (Cu) B2016RD B2016RDL (For 100% Application) (For 1600A 2000A Frames)
Base Mounting Hardware Supplied customer.
Handle Extension Included with breaker. Additional handle extensions available.
Single Handle Extension
Catalogue Number HEX6
Catalogue number includes connection,
terminals, hardware either line side load side 3-pole breaker.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Motor Circuit Protectors
Selection Guide Ordering Information
Circuit Breakers Motor Protection
Breaker Type Rated Current Rated Output 3-Phase Motors Protected 380/415V Max. 500V Max. Setting Current Inverse-Time Overload Release Instantaneous Short Circuit Release Trip Class Standard Switching Capacity Catalogue Number High Switching Capacity Catalogue Number
Without Adjustment Trip Class, without Phase Unbalance Detection
380/415 380/415
FWMP FWMP FWMP FWMP KWMP LWMP
40-80 80-100 100-160 160-205 160-315 250-500
FWMP3080L FWMP3100L FWMP3160L FWMP3205L
380/415
HFWMP3080L HFWMP3100L HFWMP3160L HFWMP3205L HKWMP3315W HLWMP3500W
380/415
KWMP3315W LWMP3500W
380/415
With Adjustment Trip Class, with Phase Unbalance Detection FWMP-J FWMP-J FWMP-J FWMP-J KWMP-J LWMP-J 40-80 80-100 100-160 160-205 160-315 250-500 5/10/15/20 5/10/15/20 5/10/15/20 10/15/20/30 FWMP3080JL FWMP3100JL FWMP3160JL FWMP3205JL
380/415
HFWMP3080JL HFWMP3100JL HFWMP3160JL HFWMP3205JL HKWMP3315JW HLWMP3500JW
380/415
KWMP3315JW LWMP3500JW
380/415
Motor Circuit Protectors Combination Starters HMCP HMCP HMCP HMCP HMCP HMCP HMCP HMCP HMCP HMCP HMCP HMCP 300-1000 450-1500 750-1500 1000-2000 1125-2250 1250-2500 1500-3000 1750-3500 2000-4000 1800-6000 1800-6000 1800-6000 HMCPE100R3 HMCPJ250C5 HMCPJ250G5 HMCPJ250K5 HMCPJ250L5 HMCPJ250W5 HMCP400N5 HMCP400R5 HMCP400X5 HMCP600L6W HMCP600L6W HMCP600L6W
Combination ratings with Freedom® ADVANTAGE® Control, contact Cutler-Hammer.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Selection Guide Ordering Information
Special Calibration Special non-UL listed calibrations available certain ambient temperatures other than frequencies other than 50/60 Reduced interrupting ratings will apply applications. Calibration suffix catalogue number complete breaker when ordering listed ampere ratings breakers used ambients. Contact Cutler-Hammer availability. Moisture-Fungus Treatment Cutler-Hammer Circuit Breaker cases moulded from glass-polyester which does support growth fungus. parts which susceptible growth fungus will require special treatment. Order description.
Accessory Frame E125 J250
Special Calibration Moisture-Fungus Treatment
Accessory Type Frame
E125
J250
External Accessory Catalogue Numbers Non-Padlockable Handle Block Padlockable Handle Block Padlockable Handle Lock Hasp Cylinder Lock Interlock (Provision Only) Slide Interlock Requires Breakers Walking Beam Interlock Requires Breakers Electrical Operator Field Fitted Field Fitted Field Fitted Field Fitted Factory Fitted Field Fitted Field Fitted Factory Fitted Plug-In Adapters Rear Connecting Studs Handle Mechanism Field Fitted Only Field Fitted Field Fitted Flex Shaft Type Rotary Type Slide Plate Direct Test Electronic Portable Test (Digitrip Only) STK2 STK2 STK2 STK2 KYKFJ 1294C01H01 223C77G03 EFHB EFPHB0FF EFPHL0FF FJPHB0FF FJPHL0FF PHB3 PLK3 Order Description KYK3 SBK3 Order Description E0P3T07 E0P3T11 E0P3T07DC E0P3T11DC MOP3PO3DC E0P4T07 E0P4T11 E0P4T26 E0P4MT21 E0P4T21 E0P5T07 E0P5T11 E0P5T21K E0P5T22 E0P5T26 E0P6T08 E0P6T11 E0P6T19K E0P6T21 KYK4 SBK4 KYK4 SBK5 KYK6 LKD3 LKD4 HLK4 LKD4 PLK5 HLK6
R-Frame breakers equipped
with electronic trip units operate reliably ambient temperatures Contact Cutler-Hammer catalogue numbers.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Selection Guide Ordering Information
Accessory Pole Location Frame E125 J250
Field Catalogue Numbers Alarm Lockout
Make
Make/Break Make/2 Break
Left Right Left Right Left Right Left Right Left Right Left Right
Factory Only Factory Only Factory Only Factory Only Factory Only Factory Only Factory Only Factory Only
ALM1M1BEPK ALM2M2BEPK AUX1A1BPK AUX2A2BPK AUXALRMEPK SNT120CPK SNT480APK SNT060CPK SNT060CPK UVR120APK UVR480APK UVR024CPK UVR048DPK
A1L3LPK A1L3RPK A2L3LPK A2L3RPK A1X3PK A1X3PK A2X3PK A2X3PK A3X3LPK A3X3RPK AAL3LPK AAL3RPK SNT3P11K SNT3P11K SNT3P11K SNT3P11K SNT3P04K SNT3P04K SNT3P06K SNT3P06K LST3LPK LST3RPK UVH3LP08K UVH3RP08K UVH3LP11K UVH3RP11K UVH3LP21K UVH3RP21K UVH3LP23K UVH3RP23K
A1L4LPK A1L4RPK A2L4LPK A2L4RPK A1X4PK A1X4PK A2X4PK A2X4PK A3X4PK A3X4PK AA114LPK AA114RPK SNT4LP11K SNT4RP11K SNT4LP11K SNT4RP11K SNT4LP03K SNT4RP03K SNT4LP23K SNT4RP23K LST4LPK LST4RPK UVH4LP08K UVH4RP08K UVH4LP11K UVH4RP11R UVH4LP21K UVH4RP21K UVH4LP23K UVH4RP23K
A1L5LPK A1L5RPK A2L5LPK A2L5RPK A1X5LPK A1X5RP A2X5LPK A2X5RPK A3X5LPK A3X5RPK AA115LPK AA115RPK SNT5LP11K SNT5LP11K SNT5LP03K SNT5LP23K LST5LPK UVH5LP08K UVH5LP11K UVH5LP21K UVH5LP23K
A1L6RPK A2L6RPK A2X6RPK SNT6P11K SNT6P11K SNT6P03K SNT6P23K LST6RPK UVH6RP08K UVH6RP11K UVH6RP21K UVH6RP23K
Break
Auxiliary Switch
Auxiliary Switch/ Alarm Lockout Shunt Trip Standard
Left Right Left Right Left Right Left Right Left Right
Shunt Trip Energy Undervoltage Release Mechanism
Left Right Left Right Left Right Left Right
Shunt trip undervoltage release only
mounted left pole L-Frame breakers equipped with electronic trip units.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Handle Mechanisms
Selection Guide Ordering Information
Handle Mechanisms Overview Handle Mechanisms used operate moulded case circuit breakers, moulded case switches motor circuit protectors. They available three basic configurations Flange Mounted, Throughthe-Door Direct (Close-Coupled) providing safe, dependable operation ease installation. Flange Mounted Flex Shaft Through-the-Door Universal Rotary Direct (Close-Coupled) Universal Direct Euro Direct Handle mechanisms typically used enclosed circuit breakers, control panels motor control centres many different applications. Cutler-Hammer handle mechanism virtually need. Flange Mounted Handle Mechanisms Flex Shaft comes preset from factory, requiring only minor field adjustments installation, which takes about minutes significant time savings compared installation other types flange handle mechanisms. Flex Shaft mechanism also takes less interior enclosure space than competitive Flex Shaft Ordering Information
Breaker Frame Flexible Shaft Length Meters (Feet) Catalogue Number 0.91m 1.22m 1.25m 1.83m 2.13m 2.44m 2.74m 3.05m (10)
designs handle fits standard flange cutouts. Flex Shaft handle remotely mounted from breaker, where operator "funnelling" cable through conduit. Flex Shaft Listed under File E64893 meets requirements.
EHMFS03I EHMFS04I EHMFS05I EHMFS06I EHMFS07I EHMFS08I EHMFS09 EHMFS10 JHMFS03I JHMFS04I JHMFS05I JHMFS06I JHMFS07I JHMFS08I JHMFS09 JHMFS10 F0S03CI F3S03CI F0S04CI F3S04CI F4S04CI F5S04CI F6S04CI F0S05CI F3S05CI F4S05CI F5S05CI F6S05CI F0S06CI F3S06CI F4S06CI F5S06CI F6S06CI F0S07CI F3S07CI F0S08CI F3S08CI F0S09C F3S09C F0S10C F3S10C F4S10C F5S10C
Note: Type 4/4X handle mechanisms available. Suffix before complete Catalogue Number. Suffix complete Catalogue Number 152.4 (6-inch) handle. Original narrow handle design Suffix) available. Remove from Catalogue Number. Note: When selecting length shaft, ensure minimum bending radius 101.6 inches) maintained operate properly.
Flex Shaft Replacement Door Hardware Kits
Breaker Frame Flexible Shaft Catalogue Number
5108A56G01 5108A56G02 5108A56G15 5108A56G16 5108A56G17 5108A56G18 5108A56G19 5108A56G20
LONR LH/RH LONR LH/RH LH/RH LONR LH/RH LH/RH
Door Hardware Hoffman Enclosure
Latch Panel Height (Inches) Catalogue Number
point point
1016 (40) Over 1016 (40)
HDH-2R HDH-3R
Flex Shaft
Flange Mounted Handle Mechanisms mount flange enclosure door. Flex Shaftis extra heavy-duty mechanism that includes flexible shaft various lengths, meters feet) through meters feet) with various size enclosures. Flex Shaft Handle will accept three padlock shackles, each with maximum diameter (3/8-inch). used with NEMA fabricated enclosures. optional handle available Flex Shaft that suitable with NEMA environments.
standard method shipment includes mechanism preset factory; however, minor field adjustments required. Flex Shaft Accessories through R-Frame) Standard Door Hardware (Required Adapter Kit)
Latch Panel Height (Inches) Catalogue Number
Flange Mounted Instruction Leaflets
Breaker Frame Instruction Leaflet/FRED Number
Flex Shaft 29C265 29C518 15609 15605 15604 15606 15606 15606
point point point
(30) 1016 (40) Over 1016 (40)
DH1R DH2R DH3R
Door Hardware Adapter (Required Standard Door Hardware)
Catalogue Number AMTDHA
consists special door hardware
door interlock pin. Available right hand flange mounting only.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Handle Mechanisms
Selection Guide Ordering Information
Through-the-Door Handle Mechanisms Universal Rotary Ordering Information
Shaft Length (Inches) Handle Colour Complete Catalogue Number Cutler-Hammer Rotary Complete Catalogue Number IP65 IP66
EF-Frame 152.4 304.8 (12) 152.4 304.8 (12) FJ-Frame 152.4 304.8 (12) 152.4 304.8 (12) G-Frame 152.4 304.8 (12) 152.4 304.8 (12)
Rotary
Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black
EHMVD06B EHMVD12B EHMVD06R EHMVD12R FJHMVD06B FJHMVD12B FJHMVD06R FJHMVD12R GHMVD06B GHMVD12B GHMVD06R GHMVD12R FHMVD06B FHMVD12B FHMVD06R FHMVD12R JHMVD06B JHMVD12B JHMVD06R JHMVD12R KHMVD06B KHMVD12B KHMVD06R KHMVD12R LHMVD06B LHMVD12B LHMVD06R LHMVD12R HMVD15HB HMCC5W HMVD15HR HMCC5W HMVD15HB HMCC6W HMVD15HR HMCC6W
WHM1B06 WHM1B12 WHM1R06 WHM1R12 WHM2B06 WHM2B12 WHM2R06 WHM2R12 WHM3B06 WHM3B12 WHM3R06 WHM3R12 WHM4B06 WHM4B12 WHM4R06 WHM4R12 WHM5B06 WHM5R12 WHM5B06 WHM5R12
WHM1B06X WHM1B12X WHM1R06X WHM1R12X WHM2B06X WHM2B12X WHM2R06X WHM2R12X WHM3B06X WHM3B12X WHM3R06X WHM3R12X WHM4B06X WHM4B12X WHM4R06X WHM4R12X WHM5B06X WHM5R12X WHM5B06X WHM5R12X
F-Frame 152.4 304.8 (12) 152.4 304.8 (12) J-Frame 152.4 304.8 (12) 152.4 304.8 (12) K-Frame 152.4 304.8 (12) 152.4 304.8 (12) MDL-Frames 152.4 304.8 (12) 152.4 304.8 (12) N-Frame 152.4 304.8 (12) R-Frame 152.4 304.8 (12)
Cutler-Hammer Rotary suitable with NEMA enclosure types. Rotary handle mechanisms include handle "Lock Off," prevent turning breaker while position. Rotary handles indicate ON/OFF/ Tripped/Reset positions, however, Universal Rotary added feature international markings (O). Cutler-Hammer Rotary handle metal, Universal Rotary made moulded material. Cutler-Hammer Rotary handle black Universal Rotary available black yellow/red.
Through-the-Door Instruction Leaflets/ FRED Number
Breaker Frame Cutler-Hammer Rotary Universal Rotary
15594 15599 15600 15601 15602
29C517 29C519 29C250 29C250 29C250 29C250 29C250
Complete catalogue number includes
handle, mechanism, shaft mounting hardware.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Handle Mechanisms
Selection Guide Ordering Information
Direct (Close-Coupled) Handle Mechanisms Euro Direct handle mechanism used through R-Frames. Direct available with black yellow handle, with without shroud. suitable with NEMA enclosures. only with G-Frame (GD, GHC, GMCP).
Universal Direct
escutcheon ring interlock clip provided standard. standard design includes lock-off feature. Universal Direct handle mechanism listed, 60947-1/2 meets requirements. Euro Direct handle mechanism IEC-240-1. Direct listed meets requirements.
Universal Direct Ordering Information
Frame Universal Direct Domestic with Interlock (white) Catalogue Number without Interlock (white) Universal Direct International without Interlock (charcoal with global label)
EHMCCBI JHMCCBI
EHMCCB JHMCCB
EHMCCR JHMCCR
Euro Direct Ordering Information
Frame Catalogue Number Black Handle Handle
Euro Direct
HMCC3B HMCC4B HMCC5B HMCC6B
HMCC3R HMCC4R HMCC5R HMCC6R
Direct Ordering Information
Frame Catalogue Number Black Handle with Shroud without Shroud Yellow Handle with Shroud without Shroud
GMCP
Direct
HRGCC1S HRGCC1S HRGCC1S HRGMC1S
HRGCC10 HRGCC10 HRGCC10 HRGMC10
HRGCC3S HRGCC3S HRGCC3S HRGMC3S
HRGCC30 HRGCC30 HRGCC30 HRGMC30
Direct (Close-Coupled) Handle Mechanisms mount directly circuit breaker. They used shallow enclosures where standard variable depth Through-the-Door type mechanism practical cannot used. They typically applications where high volume, standardized enclosures being fabricated. Universal Direct handle mechanism designed exclusively Cutler-Hammer E125 J250 circuit breakers. available standard with door interlock prevent opening enclosure while circuit breaker position. also available without door interlock.
Direct (Close-Coupled) Instruction Leaflets
Frame Instruction Leaflet/FRED Number Universal Direct Euro Direct Direct
29C255 29C256
29C288A 29C288A 29C288A 29C289 29C290 29C291
15567
Suitable 3-pole G-Frame.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Selection Guide Ordering Information
Remote Controlled Operating Mechanisms Cutler-Hammer Circuit Breakers (sizes 2000 amperes) equipped with motorized operating mechanisms remote in-service closing opening. normal remote opening, solenoid operating mechanisms K-Frames available circuit breakers motorized operating mechanisms (sizes 2500 amperes) solenoid operating mechanisms motor operators always supplied with locking device padlocks. This device used electrical mechanical blocking operating mechanism. remote operating mechanisms equipped with manual actuator local operation. Alarm Lockout alarm switches operate when circuit breaker tripped short circuit overcurrent, also when tripped shunt trip undervoltage release. Auxiliary Switches Auxiliary switches used signalling control purposes. various functions auxiliary switches (changeover) shown table right. Shunt Trips shunt trip used remote tripping. coil shunt trip rated only short-time operation. permissible with circuit breaker open apply continuous opening command shunt trip order prevent breaker from closing. This means that interlocking circuits with continuous commands with shunt trips. Possible Equipment L-Frame Circuit Breakers with Auxiliary Alarm Switches
3-Pole Circuit Breakers left 4-Pole Circuit Breakers
right
left
right
F-Frame Motor Protection
Shunt Trip Undervoltage Release Module Built-In) Auxiliary Switch Alarm Switch R-Frame Circuit Breakers Only
E125 J250 Auxiliary Switch Alarm Switch Right Pole. E125 J250 Shunt Trip Left Pole.
Undervoltage Releases circuit breaker cannot closed until undervoltage release energized. release energized, circuit breaker only perform idle switching operation. Frequent idle switching actions should avoided they shorten endurance circuit breaker.
Contact making auxiliary alarm switches function switching position circuit breaker
Position Toggle Handle Drive (Equivalently Applicable Rotary Drives) Position Auxiliary Switch Position Alarm Switch
RESET
Tripped
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Time-Current Curves
Tripping Characteristics operating values specified inverse time overcurrent releases (thermal overload releases, releases) mean values scatter bands setting ranges from cold state with uniform current loading conducting paths. tripping characteristics instantaneous (electromagnetic) short circuit releases ("n" releases) based rated phase current which case circuit breakers with adjustable thermal overload releases also upper value setting range. With lower setting current, correspondingly higher multiple obtained operating current release. Individual time-current curves L-Frame Digitrip Electronic Trip Curves available upon request. Tripping time characteristics (Thermal Memory)
Type Tripping characteristics circuit breakers plant protection, release fixed setting 500-1300 breaker 16-63A; 1300-1800 breaker 70-100A
Type E125 Tripping characteristics E125 circuit breakers plant protection, 18/25/40/70 release fixed setting 500-1300 breaker 16-63A; 1300-1800 breaker 70-125A
10000 5000 3000 2000 1000
10000 5000 3000 2000 1000
Notes: thermal overload release instantaneous (electromagnetic) short circuit release
Notes: fixed inverse-time overcurrent release Max. Trip Time fixed electromagnetic release total operation time interrupting rating determines curve
TIME SECONDS
.005 .003 .002 .001
TIME SECONDS
Maximum Trip Time
.005 .003 .002 .001
Min. Trip Time 50-125 30-32 15-16
Poles Series Only Minimum Trip Time
CURRENT MULTIPLES
CURRENT MULTIPLES
Cold
Cold
Type J250 Tripping characteristics J250 circuit breakers plant protection, 25/40/70 release adjustable
10000 5000 3000 2000 1000
Type Tripping characteristics circuit breakers plant protection, 45/70 release adjustable
10000
Cooling Down
Notes: thermal overload release instantaneous (electromagnetic) short circuit release
5000 3000 2000 1000
Notes: thermal overload release instantaneous (electromagnetic) short circuit release
Warm
Heating
TIME SECONDS
.005 .003 .002 .001
5XIn
10XIn
TIME SECONDS
Warm
5XIn
10XIn
(660/690V) (380/415V) (220/240V)
(660/690V) (380/415V) (220/240V)
.005 .003 .002 .001
CURRENT MULTIPLES
CURRENT MULTIPLES
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Time-Current Curves
Tripping Characteristics operating values specified inverse time overcurrent releases (thermal overload releases, releases) mean values scatter bands setting ranges from cold state with uniform current loading conducting paths. tripping characteristics instantaneous (electromagnetic) short circuit releases ("n" releases) based rated phase current which case circuit breakers with adjustable thermal overload releases also upper value setting range. With lower setting current, correspondingly higher multiple obtained operating current release. Type Tripping characteristics circuit breakers plant protection, release adjustable
10000 5000 3000 2000 1000 .005 .003 .002 .001
Type Tripping characteristics circuit breakers plant protection, 45/70 release adjustable
10000 5000 3000 2000 1000
Notes: thermal overload release instantaneous (electromagnetic) short circuit release
Notes: thermal overload release instantaneous (electromagnetic) short circuit release
TIME SECONDS
TIME SECONDS
5XIn
10XIn
5XIn
10XIn
(660/690V)
(660/690V)
.005 .003 .002 .001
(380/415V)
(380/415V) (220/240V)
(220/240V)
CURRENT MULTIPLES
CURRENT MULTIPLES
Type Tripping characteristics circuit breakers plant protection, release adjustable
10000 5000 3000 2000 1000 .005 .003 .002 .001
Notes: thermal overload release instantaneous (electromagnetic) short circuit release
TIME SECONDS
5XIn
10XIn
(660/690V)
(380/415V) (220/240V)
CURRENT MULTIPLES
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes
Time-Current Curves
Type Tripping characteristics circuit breakers, 50/70/100 with solid state overcurrent release
7200
Notes:
1000
Inverse-time overload release current (adjustable) Short time delayed short circuit release Tripping current (adjustable) Delay time (adjustable) Instantaneous short circuit release Tripping current (fixed setting) Setting Multiples Shown)
TIME SECONDS
Working Temperature Range tolerance bands shown applicable ambient temperature range +60°C circuit breaker.
.005 15Xlr
CURRENT MULTIPLES
Type Tripping characteristics circuit breakers, 70/100 with solid state overcurrent release
7200
Notes:
1000
Inverse-time overload release current (adjustable) Short time delayed short circuit release Tripping current (adjustable) Delay time (adjustable) Instantaneous short circuit release Tripping current (fixed setting) Setting Multiples Shown)
TIME SECONDS
Working Temperature Range tolerance bands shown applicable ambient temperature range +60°C circuit breaker.
PG.29B.01A.T.U
.005 15Xlr
CURRENT MULTIPLES
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Time-Current Curves
Characteristics FWMP, KWMP, LWMP Circuit Breakers Motor Protection with Solid State Overcurrent Releases tripping times inversetime delayed overcurrent releases only valid preloaded (cold) state. operating temperature (after load with rated current), tripping times reduced approximately 33%. After overcurrent trip, tripping times reduced according tripping time characteristics (see figure below) that cooling down some minutes required before restarting motor. During first minute after tripping, reclosing circuit breaker blocked. Type FWMP, KWMP, LWMP Tripping characteristics FWMP, KWMP, LWMP circuit breakers motor protection with solid state overcurrent releases
7200
1000
Class
TIME SECONDS
100Xle
CURRENT MULTIPLES
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Current Limiting Curves
Current Limiting Characteristics Maximum Values Type E/LW Current limiting characteristics 50/60 380/415
Type E/LW Current limiting characteristics 50/60 660/690
=0.25
=0.25 CUT-OFF CURRENT
CUT-OFF CURRENT
SHORT CIRCUIT CURRENT ISrms
SHORT CIRCUIT CURRENT ISrms
Type NW/RW Current limiting characteristics 50/60 380/415
Type FW/LW Maximum values 50/60 380/415
=0.25
CUT-OFF CURRENT
VALUE X105
SHORT CIRCUIT CURRENT ISrms
SHORT CIRCUIT CURRENT ISrms
Type FW/LW Maximum values 50/60 660/695
Type NW/RW Maximum values
VALUE X106
VALUE X105
Notes: 50/60 380/415 50/60 660/690
SHORT CIRCUIT CURRENT ISrms
SHORT CIRCUIT CURRENT ISrms
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Dimensions, (inches)
G-Frame
Front Cover Cutout Front View 3-Pole Side View
56.34 (2.218) 76.20 (3.000) 76.20 (3.000)
81.74 (3.218) 66.67 (2.625)
123.82 (4.875)
E125-Frame
Front Cover Cutout Breaker 3.56 (0.14) 22.86 (0.900)
Front View 3-Pole
Side View
46.99 (1.850) Handle 11.94 (0.47) 23.88 (0.94) 76.20 (3.000) 76.96 (3.03) 139.70 (5.500)
33.02 Dia. (1.300)
70.35 (2.770)
J250-Frame
Front Cover Cutout 15.86 (0.625) 7.137 (0.281) 77.80 (3.063) 12.70 (0.500) Breaker
Front View 3-Pole
Side View
31.75 (1.250) 4.75 (0.188) 51.99 (2.047) Handle 100.38 (3.952) 177.80 (7.000)
101.60 (4.000)
26.97 (1.062) 104.77 (4.125) 87.38 (3.440)
K-Frame
Front Cover Cutout
Front View 3-Pole
Side View
Breaker 8.74 (0.344) 95.25 (3.750) 21.03 (3.750) Handle 41.66 (1.640) 4.77 (0.188) 33.35 (1.313) 66.67 (2.625) 121.46 (4.782) 139.45 (5.490) 104.00 (4.094) 151.55 (5.967) 257.17 (10.125)
31.75 (1.250)
60.73 (2.391)
Dimensions parentheses inches.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Frame Sizes through
Dimensions, (inches)
L-Frame (Bus extensions included) L-Frame
Front Cover Cutout 22.25 (0.875) 69.90 (2.752) Front View 3-Pole 209.60 (8.252) 69.90 (2.752) Side View 111.10 (4.374) 103.20 (4.063) 96.80 (3.811)
Breaker 43.66 (1.719) 87.32 (3.438) 83.34 (3.281) 33.65 (1.325) 58.22 (2.292) Handle
63.50 (2.500)
120.30 (4.736)
142.60 (5.614)
406.40 (16.00) 381.00 (15.000)
4.77 (0.188) 38.10 (1.500)
242.30 (9.539)
273.10 (10.752)
333.00 (13.110)
92.48 (3.641) 184.94 (7.281)
323.00 (12.716) 5.10 (0.200) 11.10 Dia. (0.437) 12.70 (0.500) 139.70 (5.500) 44.50 (1.752) 13.00 (0.512) 24.60 (0.968) 10.00 (0.394)
N-Frame
Front Cover Cutout Front View 3-Pole Side View
Breaker 87.32 (3.438) 43.63 (1.718) 234.95 (9.250)
6.35 (0.250) 406.40 (16.000)
96.77 (3.810)
Handle 38.10 (1.500) 80.94 (3.187)
4.77 (0.188)
161.92 (6.375) 209.55 (8.250) 139.68 (5.499)
R-Frame
Front Cover Cutout 368.30 (14.500) 3.96 (0.156) 184.15 (7.250) 209.55 (8.250) Connectors Rotated Breaker Front View 3-Pole Side View 2.25 (0.089)
129.38 (5.094) 246.07 (9.688) Handle
196.85 (7.750) 406.40 (16.000) 381.00 (15.000)
330.20 (13.000)
Holes 11.12 Dia. (0.438)
166.70 (6.563) 327.81 (12.906) 393.70 (15.500) 228.60 (9.000) 171.45 (6.750)
Dimensions parentheses inches.
PG.29B.01A.T.U
Contents
Moulded Case Circuit Breakers 16-2500 Amperes 60947-2 Applications
Cutler-Hammer Sales Offices
Sales Offices
Country Address Office Phone Office Country Address Office Phone Office
Argentina Cutler-Hammer, Inc. Calle Reconquista 656, Piso (1003) Capital Federal Buenos Aires, Argentina Australia Cutler Hammer P.O. Rosebery, 1445, Australia Brazil Cutler-Hammer, Inc. Eletromar Plant Estrada Velha PaPavuna, 21058-900 Janeiro-RJ-Brazil Canada Cutler-Hammer Canada 3228 South Service Road, 5040 Station Burlington, Ontario Chile Cutler-Hammer, Inc. Neveria 4631, Office /203 Condes 6761670 Santiago, Chile China Cutler-Hammer China Hong Road, Suzhou Industrial Park Suzhou, 215021, Costa Rica (506) Cutler-Hammer, Inc. Industrial Control Power Distribution 235-6022 Operations-Worldwide Power Distribution Division Apartado Postal 10156 1000 Jose, Costa Rica Egypt Cutler-Hammer, Inc. Shehab Street- #11, Mohandessin 12411 Cairo, Egypt Salvador Cutler-Hammer, Inc. Centro Comercial Villas Local Salvador, Salvador France Cutler-Hammer Chataigneraie 73000 Barberaz, France Germany Eaton GmbH Oranienpassage, 57258 Freudenberg, Germany Guatemala Cutler-Hammer, Inc. Avenida Reforma 7-62 zona Edificio Aristos Reforma, Oficina N°704 Ciudad Guatemala, Guatemala Honduras Cutler-Hammer, Inc. Honduras Edificio Miramontes Plaza Apart. Hoteles Continental S.A. Segundo nivel, local N°10 Tegucigalpa, Honduras Indonesia Cutler-Hammer Suite 503A Sentra Mulia Rasuna Said No.8 Jakarta 12940, Indonesia (62-21) 522-2020 (62-21) 522-2110 (504) 235-7554 (502) 362-9168 (502) 385-0343 (49-2734) 4663-0 (49-2734) 4760-5 (33-4) 79604763 (33-4) 79604766 (503) 263-6557 (503) 264-4144 (20-2) 338-6170 (20-2) 338-2025 (506) 235-9156 (86-512) 716-3728 (86-512) 716-9535 (56-2) 207-1695 (56-2) 207-1699 (905) 333-6442 (905) 631-4248 (55-21) 865-3912 (55-21) 290-1645 (61-2) 9693-9333 (61-2) 9693-1258 (54-11) 4315-4066 (54-11) 4314-8946
Jordan Cutler-Hammer, Inc. P.O. 510449 Amman 11151, Jordan Korea Eaton Limited-Korea Floor, Building 832-2, Yeoksam-dong, Kangnam-ku Seoul, 135-750, Korea Malaysia Eaton Corporation Regional Office Alpha Executive Business Center 1005 Level Phileo Tamansara 16/11 Tamansara 46350 Petaling Jaya, Selangor, Malaysia Mexico Cutler Hammer, Inc. Rojo Gomez 1300 Col. Sn.Miguel Iztapalapa Mexico City 09360 Mexico Zealand Cutler Hammer P.O. 12648 Penrose, Auckland, Zealand Nicaragua Cutler-Hammer, Inc. (505) 270-0920 Edificio Ofiplaza Retiro Modulo N°5-1.1 semaforos antrada antiguo, Nejapa Country Club Managua, Nicaragua Panama Cutler-Hammer, Inc. Avenida Ricardo Alfaro Edifico Plaza Edison, Segundo Nivel, Oficina Ciudad Panama, Panama Saudi Arabia Cutler-Hammer, Inc. P.O. 19651, Riyadh 11445 Kingdom Saudi Arabia Singapore Cutler-Hammer Seng Drive #03-01 Marconi Building Singapore 535216 Thailand (66-2) Cutler-Hammer (C-H 1254) Eaton Technologies Limited, 91/1 Chailyo Building, 643-9504-8 Floor, Rama Road, Huaykwang Bangkok 10320 Thailand United Kingdom Cutler-Hammer Carina, Sunrise Parkway Linford Wood Milton Keynes MK146NR United States Cutler-Hammer, Inc. 1000 Cherrington Pittsburgh, 15108 Venezuela Cutler-Hammer, Inc. Avda. Libertador, Rosal, Edificio Lex, Piso Caracas 1060, Venezuela United Arab Emirates Cutler-Hammer Inc. P.O. 9398, Dubai World Trade Centre Level Dubai, United Arab Emirates (971-4) 331-3938 (971-4) 332-9239 (58-2) 953-1697 (58-2) 953-2585 2841 (412) 893-3300 (44-0-1908) 541600 (44-0-1908) 660527 (66-2) 643-9509 (65) 382-7330 (65) 382-7262 (966-1) 460-2275 (966-1) 460-2991 (507) 321-0288 0289 (507) 321-0290 (505) 270-0900 (82-2) 557-0313 (82-2) 557-1634 (52-5) 804-8230 (525-5) 804-8232 (60-3) 737-2970 (60-3) 737-2960 (82-2) 557-0313 (82-2) 557-1634 (962-6) 474-0660 962-6) 744-660
PG.29B.01A.T.U
Contents
Typical Specifications Cutler-Hammer Moulded Case Circuit Breakers
circuit breakers shall meet exceed standards defined 60947-2. Electrical circuits shall protected Cutler-Hammer World Moulded Case Circuit Breakers manufactured Cutler-Hammer. Each pole one-, two-, three-pole circuit breakers shall provide complete circuit overcurrrent protection having inverse time instantaneous tripping characteristics and, where applicable, current limiting. circuit breaker shall available interrupting families that provide 35-65-100 380-415 volts circuit breakers shall operated toggle-type handle have quick-make, quick-break, over-centre switching mechanism that mechanically trip-free from handle that contacts cannot closed against short circuit currents. Tripping overload short circuits shall clearly indicated position handle. positions shall clearly marked cover circuit breaker along with international symbols handle, providing positive indication circuit breaker contact position. Additionally, colour-coded indication circuit breaker contact position shall provided: green OFF, white TRIPPED. easily accessible Push-ToTrip button mechanically exercising trip unit shall provided cover each circuit breaker. poles multi-pole circuit breaker shall constructed ensure simultaneous open, close, trip operations. Circuit breakers shall completely enclosed high strength glass-polyester case. Noninterchangeable trip circuit breakers shall factory sealed; interchangeable trip circuit breakers shall have trip unit sealed prevent tampering. Ampere ratings shall clearly visible from front circuit breaker. Contacts shall nonwelding silver alloy. extinction shall accomplished means DE-ION® extinguishers consisting metal grids mounted insulating support. minimum interrupting ratings circuit breakers shall least equal available short circuit current line terminals. circuit breakers applied series rated applications subject test data verification. Circuit breakers frame sizes amperes through amperes shall equipped with thermal-magnetic trip units. Circuit breakers amperes through 2500 ampere frame sizes shall equipped with electronic trip units that insensitive changes ambient temperature within normal operating temperature range circuit breaker. ampere ampere frame sizes shall designed accept either thermal-magnetic electronic interchangeable trip units. Electronic trip units shall sensing type have unpowered thermal memory. Circuit breaker ratings modifications shall indicated drawings. Circuit breakers shall inverse time instantaneous trip type provided thermal-magnetic electronic trip elements with either standard interrupting, high interrupting, current limiting characteristics required. Moulded case circuit interrupters (motor circuit protectors) shall instantaneous (magnetic) only type, providing instantaneous short circuit protection means front adjustable trip unit. Moulded case switches shall same construction related listed circuit breaker equipped with factory sealed, nonadjustable, high instantaneous only short circuit protection. Moulded case switches shall have overload level fault protection provided shall marked with maximum withstand rating denoting type level upstream protection required. Moulded case switches shall listed 60947-2. Internally mounted accessories including alarm (signal)/ lockout switches, auxiliary switches, shunt trips, undervoltage released mechanisms shall plug-in type shall listed field fitting circuit breakers which factory sealed. Electrical operators circuit breakers ampere frame size below shall solenoid type with maximum five-cycle closing characteristics. Electrical operators circuit breaker frame sizes amperes through 2500 amperes shall motor driven type. electrical operators shall cover mounted. electrical operators shall listed field installation 60947-2. Electrical characteristics accessories shall indicated drawings. Circuit breakers amperes rating shall supplied one-, two-, three-, four-pole models, specified drawings. Circuit breakers ratings amperes through 1250 amperes shall supplied two-, three-, four-pole models. 2500 ampere circuit breaker available three- four-pole models specified drawings. Accessory wiring shall brought through side rear circuit breaker, connected terminal block mounted side circuit breaker, specified. ability route accessory wiring opposite side circuit breaker through trough base shall provided. Circuit breakers shall provided with uniformly designed nameplates clearly indicate type, rating, listing/ recognition/certification marks, accessory details, other information defined 60947-2.

Other recent searches


Si7862ADP - Si7862ADP   Si7862ADP Datasheet
Si7862DP - Si7862DP   Si7862DP Datasheet
Si7862ADP-T1 - Si7862ADP-T1   Si7862ADP-T1 Datasheet
Si7862DP-T1 - Si7862DP-T1   Si7862DP-T1 Datasheet
Si7862ADP-T1-E3 - Si7862ADP-T1-E3   Si7862ADP-T1-E3 Datasheet
Si7862DP-T1-E3 - Si7862DP-T1-E3   Si7862DP-T1-E3 Datasheet
REJ03B0011-0400 - REJ03B0011-0400   REJ03B0011-0400 Datasheet
PB0229011110 - PB0229011110   PB0229011110 Datasheet
AD622 - AD622   AD622 Datasheet
ACT8CSV - ACT8CSV   ACT8CSV Datasheet
ACT8CSV-6 - ACT8CSV-6   ACT8CSV-6 Datasheet
74LCXH245 - 74LCXH245   74LCXH245 Datasheet
2SC2979 - 2SC2979   2SC2979 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive