The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Split Bolt Connectors Type High Strength Split Bolt Connectors


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Blackburn
Split Bolt Connectors
Type High Strength Split Bolt Connectors
Cat. Conductor Range (AWG KCMIL) Range Min. Equal Main with Max. Main Dimensions (in.)
copper copper connections Bolt high strength corrosionresistant bronze alloy Pressure copper through 40H; copper alloy used KCMIL above Bolt design KCMIL Tested Listed U.L. 486A requirements
str.-12 sol. str.-10 sol. 8H3* str.-12 sol. sol.-8 sol. 6H3* sol.-10 sol. sol.-8 sol. 4H3* sol.-8 sol. sol.-8 sol. 3H3* str.-8 sol. sol.-6 sol. 2H3* sol.-6 sol. str.-6 sol. 1H3** str.-6 sol. str.-4 sol. str.-2 sol. str.-2 sol. KCMIL-1 str. 350M KCMIL-250 KCMIL 500M KCMIL-400 KCMIL 750M KCMIL-600 KCMIL 1000M 1000 KCMIL-800 KCMIL
sol. sol. str. sol. str. sol. str. str. str. sol. sol. sol. sol. sol. sol. sol. sol. str. str. str. str.
15/16 115/16
.146 .146 .146 .170 .170 .235 .235 .235 .235 .271 .271 .330 .330 .385 .443 .580 .580 .717 .842 1.029 1.185
15/16 15/16
1/16 9/32 1/16 9/32 15/32 11/32 19/32 13/16 5/32 5/32 11/16 1/32 21/32 1/32
Will accommodate wires maximum size Will accommodate str. wires bolts U.L. Listed Certified. U.L. recognizes solid stranded conductor configurations sizes smaller stranded configurations only sizes larger.
Blackburn
Type HPS-Plated Split-Bolt Connectors with Spacer
Conductor Range (AWG KCMIL) Range Range Min. Equal Main Equal Main with Max. Main ACSR Copper Aluminum
Split Bolt Connectors
MECHANICAL CONNECTORS
Cat.
Dimensions (in.)
copper, aluminum ACSR conductors Most connectors U.L. Listed Certified copper conductor only Bolt pressure copper alloy completely plated Contoured spacer electrolytic copper through 4/0; bronze alloy above, plated Blackburn Contax recommended when used aluminum conductor
9HPS 8HPS 6HPS 4HPS 2HPS 1HPS 10HPS 20HPS 40HPS 350HPS 500HPS* 750HPS* 1000HPS*
str.-12 sol. str.-12 sol. sol.-12 sol. sol.-12 sol. sol.-8 sol. str.-8 sol. str.-6 sol. 1/0-6 str.-6 str. 4/0-4 str.-4 sol. 266.8-1/0 KCMIL-1/0 str. 397.5-1/0 KCMIL-1/0 str. 666.6-4/0 KCMIL-4/0 str. 900-477 1000 KCMIL-500 KCMIL
sol. sol. sol. sol. sol. sol. sol. sol. sol. sol. str. str. str.
15/16 115/16
.146 .146 .170 .235 .271 .330 .385 .443 .580 .717 .842 1.029 1.185
1/16 15/16 21/32 17/32
19/32 115/32 113/16 21/16 215/32 211/16 31/32 321/32 41/32
Certified. U.L. 486A
Blackburn
Split Bolt Connectors
Type HPW-Plated Split-Bolt Connectors with Spacer Washer
Conductor Range (AWG KCMIL) Range Range Min. Equal Main Equal Main with Max. Main ACSR Copper Aluminum Dimensions (in.)
Cat.No.
combinations copper, aluminum ACSR conductors Bolt pressure high strength copper alloy completely plated; spacer washer electrolytic copper through 4/0; bronze alloy above, plated Contoured spacer bell mouth washer distributes pressure over large area conductor Large contoured spacer provides wide separation between copper aluminum conductors Blackburn Contax recommended when used with aluminum conductor
6HPW 4HPW 2HPW 1HPW 10HPW 20HPW 40HPW*
1/0-6 4/0-4
sol.-12 sol. sol.-12 sol. sol.-8 sol. str.-8 sol. str.-6 sol. str.-6 sol. str.-4 sol.
sol. sol. sol. sol. sol. sol. sol.
.170 .235 .271 .330 .385 .443 .580
115/32 113/16 215/32
Certified.
Blackburn
Type Aluminum Dual-Rated Split Bolts
Cat. Conductor Range Equal Main Dimensions (in.)
Split Bolt Connectors
MECHANICAL CONNECTORS
APS06 APS04 APS02 APS11 APS21 APS41 APS350* APS500* Accommodates aluminum copper conductor combinations bolts cover range from installed with standard wrenches Corrosion resistant plated aluminum Tested listed U.L. 486B, 90°C requirements
6-10 4-10 1/0-4 2/0-4 4/0-2 KCMIL-4 KCMIL-2
11/16
11/16
1.27 1.48 1.63 2.07 2.07 2.47 3.36 3.62
123/32
Square head design certified
Type AAW-Aluminum Split-Bolt Connectors with Spacer Washers
Range Equal Main ACSR Conductor Range (AWG) Range Min. Equal Main with Max. Main Aluminum Dimensions (in.)
Cat.
6AAW 4AAW 2AAW 1AAW 10AAW 40AAW aluminum applications Bolt, nut, pressure contoured spacer aluminum alloy Large contoured spacer gives wide separation anodized prevent thread galling Blackburn Contax recommended when used aluminum conductor
1/0-4 4/0-4
sol.-8 sol. sol.-8 sol. str.-8 sol. str.-2 sol. str.-2 sol. str.-4 sol.
sol. sol. sol. sol. sol. sol.
.236 .272 .330 .443 .443 .580
19/32 115/ 21/16 21/16 215/
Blackburn
Split Bolt Connectors
Type CA-Aluminum Split-Bolt Connectors with Spacer Washer
Conductor Range (AWG) Range Min. Equal Main with Max. Main Copper Aluminum Dimensions (in.)
Cat.
10CA 40CA Bolt, washer high-strength aluminum alloy; pressure contoured spacer electrolytic copper Spacer completely plated Bolt anodized prevent seizing threads reduce galvanic corrosion when contact with copper conductor Contoured spacer bell mouth washer distributes pressure over large area conductor Blackburn Contax recommended with this Connector
sol.-6 sol. sol.-4 sol. str.-4 sol. str.-2 sol. str.-2 sol. str.-2/0 sol.
sol.-12 sol. sol.-10 sol. str.-8 sol. str.-6 sol. str.-6 sol. str.-4 sol.
.236 .272 .330 .443 .443 .580
9/32 115/32 1/16 1/16 215/32
Blackburn
Application
Blackburn line Service Post Connectors designed applications including steel structure, fence post transformer grounding involving cables. Service Posts also used cables from bar. bronze alloy while nuts coldformed from high strength, corrosion resistant copper alloy. Pressure bars copper through size, while copper alloy used size above. Bolts nuts traditional Blackburn design easy installation. Service Post Connectors available sizes accommodating copper conductor ranges #12-500 KCMIL stranded (4mm2-240mm2) #12-#2 solid (4mm2-35mm2).
Service Post Connectors
MECHANICAL CONNECTORS
Construction Ratings
Bolts used Service Post machined from high conductivity
line includes single conductor double conductor connectors. copper copper connections grounding steel structures, fence posts, transformers using cables tapping cables from design bolts machined from high conductivity bronze alloy Nuts pressure bars coldformed from high-strength copper copper alloy U.L. 486A U.L. Listed
Single Double Conductor Short Stud
Conductor Range Stranded Solid max. 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 150mm2 240mm2 min. 4mm2 6mm2 6mm2 6mm2 6mm2 35mm2 35mm2 35mm2 70mm2 95mm2 max. 10mm2 10mm2 16mm2 35mm2 35mm2 35mm2 35mm2 min. 4mm2 6mm2 6mm2 6mm2 10mm2 Maximum Diameter Range (in.) .146-.080 .170-.102 .217-.102 .271-.102 .332-.128 .385-.258 .443.258 .570-.289 .715-.373 .840-.464
Cat. SP-S SP0DS SP1DS SP2DS SP3DS SP4DS SP5DS SP6DS SP8DS SP9DS SP10DS SP-D SP0SS SP1SS SP2SS SP3SS SP4SS SP5SS SP6SS SP8SS SP9SS SP10SS Stud Size
Dimensions (in.)
/4-20 /4-20
/16-18
11/8 11/4 13/8 119/32 113/16 21/16 23/4 31/8
/8-16 11/8 /8-16 11/8 /2-13 11/4 /2-13 11/4 /8-11 11/2 /8-11 11/2 /4-10 13/4
11/16 11/4 113/32 19/16 21/4
15/64 15/64 119/64 119/64 131/64
11/16 15/16 111/16 17/8
11/4 13/4
15/16 11/2
Single Conductor Short Stud
Double Conductors Short Stud
Blackburn
Conductor Range Stranded Solid max. 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 150mm2 240mm2 min. 4mm2 6mm2 6mm2 6mm2 6mm2 35mm2 35mm2 35mm2 70mm2 95mm2 max. 10mm2 10mm2 16mm2 35mm2 35mm2 35mm2 35mm2 min.
Service Post Connectors
Single Double Conductor Long Stud
Maximum Diameter Range (in.) .146-.080 .170-.102 .217-.102 .271-.102 .332-.128 .385-.258 .443.258 .570-.289 .715-.373 .840-.464
SP-S SP0SL SP1SL SP2SL SP3SL SP4SL SP5SL SP6SL SP8SL SP9SL SP10SL SP-D SP0DL SP1DL SP2DL SP3DL SP4DL SP5DL SP6DL SP8DL SP9DL SP10DL Stud Size
Dimensions (in.)
11/8 11/8 11/4 11/4 11/2 11/2 11/2
4mm2 6mm2 6mm2 6mm2 10mm2
/4-20 /4-20
/16-18
11/8 11/4 13/8 119/32 113/16 21/16 23/4 31/8
/8-16 11/8 /8-16 11/8 /2-13 11/4 /2-13 11/4 /8-11 11/2 /8-11 11/2 /4-10 13/4
11/16 11/4 113/32 19/16 21/4
15/64 15/64 119/64 119/64 131/64
11/16 15/16 111/16 17/8
15/16 11/2
Single Conductor Short Stud
Double Conductors Short Stud
Blackburn
Types Service Entrance Connectors
Cat. Conductor Range (AWG) ACSR Copper max. min. max. min. Dimensions (in.) Bolt Head
Mechanical Service Entrance Connectors
MECHANICAL CONNECTORS
10NPW 6NPW 4NPW 2NPW
str. str. str. str.
sol. sol. sol. sol.
.337 .415 .515 .643
.156 .191 .243 .304
.562 .656 .775 .970
Service entrance connectors with bodies screws high-strength copper alloy; plated Type phosphor bronze washer, plated protect conductor distribute pressure Type used ACSR conductor Slotted head screw
Washer Type only
Type
Type
Type Neutral Span Clamp
Conductor Range ACSR Cat. Main Main
4/0-4
1/0-6
str.-2 sol.
str.-6 sol.
combination aerial cable neutral parallel groove connector dead-ending clamp that accommodates four service drops Used situations where house adjacent pole Taps installed later independent existing connections Castings high strength aluminum alloy; hardware galvanized steel; piece construction

Other recent searches


U1005-QD - U1005-QD   U1005-QD Datasheet
SPB-5720G - SPB-5720G   SPB-5720G Datasheet
RL101FG-107FG - RL101FG-107FG   RL101FG-107FG Datasheet
P4C164 - P4C164   P4C164 Datasheet
P4C164L - P4C164L   P4C164L Datasheet
OVSPBBCR44 - OVSPBBCR44   OVSPBBCR44 Datasheet
OVSPGBCR44 - OVSPGBCR44   OVSPGBCR44 Datasheet
OVSPW1BCR44 - OVSPW1BCR44   OVSPW1BCR44 Datasheet
HSCH-3206 - HSCH-3206   HSCH-3206 Datasheet
HSCH-5019 - HSCH-5019   HSCH-5019 Datasheet
BTA316B-800E - BTA316B-800E   BTA316B-800E Datasheet
AO4458 - AO4458   AO4458 Datasheet
AO4458 - AO4458   AO4458 Datasheet
AO4458L - AO4458L   AO4458L Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive