| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Split Bolt Connectors Type High Strength Split Bolt Connectors
Top Searches for this datasheetBlackburn Split Bolt Connectors Type High Strength Split Bolt Connectors Cat. Conductor Range (AWG KCMIL) Range Min. Equal Main with Max. Main Dimensions (in.) copper copper connections Bolt high strength corrosionresistant bronze alloy Pressure copper through 40H; copper alloy used KCMIL above Bolt design KCMIL Tested Listed U.L. 486A requirements str.-12 sol. str.-10 sol. 8H3* str.-12 sol. sol.-8 sol. 6H3* sol.-10 sol. sol.-8 sol. 4H3* sol.-8 sol. sol.-8 sol. 3H3* str.-8 sol. sol.-6 sol. 2H3* sol.-6 sol. str.-6 sol. 1H3** str.-6 sol. str.-4 sol. str.-2 sol. str.-2 sol. KCMIL-1 str. 350M KCMIL-250 KCMIL 500M KCMIL-400 KCMIL 750M KCMIL-600 KCMIL 1000M 1000 KCMIL-800 KCMIL sol. sol. str. sol. str. sol. str. str. str. sol. sol. sol. sol. sol. sol. sol. sol. str. str. str. str. 15/16 115/16 .146 .146 .146 .170 .170 .235 .235 .235 .235 .271 .271 .330 .330 .385 .443 .580 .580 .717 .842 1.029 1.185 15/16 15/16 1/16 9/32 1/16 9/32 15/32 11/32 19/32 13/16 5/32 5/32 11/16 1/32 21/32 1/32 Will accommodate wires maximum size Will accommodate str. wires bolts U.L. Listed Certified. U.L. recognizes solid stranded conductor configurations sizes smaller stranded configurations only sizes larger. Blackburn Type HPS-Plated Split-Bolt Connectors with Spacer Conductor Range (AWG KCMIL) Range Range Min. Equal Main Equal Main with Max. Main ACSR Copper Aluminum Split Bolt Connectors MECHANICAL CONNECTORS Cat. Dimensions (in.) copper, aluminum ACSR conductors Most connectors U.L. Listed Certified copper conductor only Bolt pressure copper alloy completely plated Contoured spacer electrolytic copper through 4/0; bronze alloy above, plated Blackburn Contax recommended when used aluminum conductor 9HPS 8HPS 6HPS 4HPS 2HPS 1HPS 10HPS 20HPS 40HPS 350HPS 500HPS* 750HPS* 1000HPS* str.-12 sol. str.-12 sol. sol.-12 sol. sol.-12 sol. sol.-8 sol. str.-8 sol. str.-6 sol. 1/0-6 str.-6 str. 4/0-4 str.-4 sol. 266.8-1/0 KCMIL-1/0 str. 397.5-1/0 KCMIL-1/0 str. 666.6-4/0 KCMIL-4/0 str. 900-477 1000 KCMIL-500 KCMIL sol. sol. sol. sol. sol. sol. sol. sol. sol. sol. str. str. str. 15/16 115/16 .146 .146 .170 .235 .271 .330 .385 .443 .580 .717 .842 1.029 1.185 1/16 15/16 21/32 17/32 19/32 115/32 113/16 21/16 215/32 211/16 31/32 321/32 41/32 Certified. U.L. 486A Blackburn Split Bolt Connectors Type HPW-Plated Split-Bolt Connectors with Spacer Washer Conductor Range (AWG KCMIL) Range Range Min. Equal Main Equal Main with Max. Main ACSR Copper Aluminum Dimensions (in.) Cat.No. combinations copper, aluminum ACSR conductors Bolt pressure high strength copper alloy completely plated; spacer washer electrolytic copper through 4/0; bronze alloy above, plated Contoured spacer bell mouth washer distributes pressure over large area conductor Large contoured spacer provides wide separation between copper aluminum conductors Blackburn Contax recommended when used with aluminum conductor 6HPW 4HPW 2HPW 1HPW 10HPW 20HPW 40HPW* 1/0-6 4/0-4 sol.-12 sol. sol.-12 sol. sol.-8 sol. str.-8 sol. str.-6 sol. str.-6 sol. str.-4 sol. sol. sol. sol. sol. sol. sol. sol. .170 .235 .271 .330 .385 .443 .580 115/32 113/16 215/32 Certified. Blackburn Type Aluminum Dual-Rated Split Bolts Cat. Conductor Range Equal Main Dimensions (in.) Split Bolt Connectors MECHANICAL CONNECTORS APS06 APS04 APS02 APS11 APS21 APS41 APS350* APS500* Accommodates aluminum copper conductor combinations bolts cover range from installed with standard wrenches Corrosion resistant plated aluminum Tested listed U.L. 486B, 90°C requirements 6-10 4-10 1/0-4 2/0-4 4/0-2 KCMIL-4 KCMIL-2 11/16 11/16 1.27 1.48 1.63 2.07 2.07 2.47 3.36 3.62 123/32 Square head design certified Type AAW-Aluminum Split-Bolt Connectors with Spacer Washers Range Equal Main ACSR Conductor Range (AWG) Range Min. Equal Main with Max. Main Aluminum Dimensions (in.) Cat. 6AAW 4AAW 2AAW 1AAW 10AAW 40AAW aluminum applications Bolt, nut, pressure contoured spacer aluminum alloy Large contoured spacer gives wide separation anodized prevent thread galling Blackburn Contax recommended when used aluminum conductor 1/0-4 4/0-4 sol.-8 sol. sol.-8 sol. str.-8 sol. str.-2 sol. str.-2 sol. str.-4 sol. sol. sol. sol. sol. sol. sol. .236 .272 .330 .443 .443 .580 19/32 115/ 21/16 21/16 215/ Blackburn Split Bolt Connectors Type CA-Aluminum Split-Bolt Connectors with Spacer Washer Conductor Range (AWG) Range Min. Equal Main with Max. Main Copper Aluminum Dimensions (in.) Cat. 10CA 40CA Bolt, washer high-strength aluminum alloy; pressure contoured spacer electrolytic copper Spacer completely plated Bolt anodized prevent seizing threads reduce galvanic corrosion when contact with copper conductor Contoured spacer bell mouth washer distributes pressure over large area conductor Blackburn Contax recommended with this Connector sol.-6 sol. sol.-4 sol. str.-4 sol. str.-2 sol. str.-2 sol. str.-2/0 sol. sol.-12 sol. sol.-10 sol. str.-8 sol. str.-6 sol. str.-6 sol. str.-4 sol. .236 .272 .330 .443 .443 .580 9/32 115/32 1/16 1/16 215/32 Blackburn Application Blackburn line Service Post Connectors designed applications including steel structure, fence post transformer grounding involving cables. Service Posts also used cables from bar. bronze alloy while nuts coldformed from high strength, corrosion resistant copper alloy. Pressure bars copper through size, while copper alloy used size above. Bolts nuts traditional Blackburn design easy installation. Service Post Connectors available sizes accommodating copper conductor ranges #12-500 KCMIL stranded (4mm2-240mm2) #12-#2 solid (4mm2-35mm2). Service Post Connectors MECHANICAL CONNECTORS Construction Ratings Bolts used Service Post machined from high conductivity line includes single conductor double conductor connectors. copper copper connections grounding steel structures, fence posts, transformers using cables tapping cables from design bolts machined from high conductivity bronze alloy Nuts pressure bars coldformed from high-strength copper copper alloy U.L. 486A U.L. Listed Single Double Conductor Short Stud Conductor Range Stranded Solid max. 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 150mm2 240mm2 min. 4mm2 6mm2 6mm2 6mm2 6mm2 35mm2 35mm2 35mm2 70mm2 95mm2 max. 10mm2 10mm2 16mm2 35mm2 35mm2 35mm2 35mm2 min. 4mm2 6mm2 6mm2 6mm2 10mm2 Maximum Diameter Range (in.) .146-.080 .170-.102 .217-.102 .271-.102 .332-.128 .385-.258 .443.258 .570-.289 .715-.373 .840-.464 Cat. SP-S SP0DS SP1DS SP2DS SP3DS SP4DS SP5DS SP6DS SP8DS SP9DS SP10DS SP-D SP0SS SP1SS SP2SS SP3SS SP4SS SP5SS SP6SS SP8SS SP9SS SP10SS Stud Size Dimensions (in.) /4-20 /4-20 /16-18 11/8 11/4 13/8 119/32 113/16 21/16 23/4 31/8 /8-16 11/8 /8-16 11/8 /2-13 11/4 /2-13 11/4 /8-11 11/2 /8-11 11/2 /4-10 13/4 11/16 11/4 113/32 19/16 21/4 15/64 15/64 119/64 119/64 131/64 11/16 15/16 111/16 17/8 11/4 13/4 15/16 11/2 Single Conductor Short Stud Double Conductors Short Stud Blackburn Conductor Range Stranded Solid max. 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 150mm2 240mm2 min. 4mm2 6mm2 6mm2 6mm2 6mm2 35mm2 35mm2 35mm2 70mm2 95mm2 max. 10mm2 10mm2 16mm2 35mm2 35mm2 35mm2 35mm2 min. Service Post Connectors Single Double Conductor Long Stud Maximum Diameter Range (in.) .146-.080 .170-.102 .217-.102 .271-.102 .332-.128 .385-.258 .443.258 .570-.289 .715-.373 .840-.464 SP-S SP0SL SP1SL SP2SL SP3SL SP4SL SP5SL SP6SL SP8SL SP9SL SP10SL SP-D SP0DL SP1DL SP2DL SP3DL SP4DL SP5DL SP6DL SP8DL SP9DL SP10DL Stud Size Dimensions (in.) 11/8 11/8 11/4 11/4 11/2 11/2 11/2 4mm2 6mm2 6mm2 6mm2 10mm2 /4-20 /4-20 /16-18 11/8 11/4 13/8 119/32 113/16 21/16 23/4 31/8 /8-16 11/8 /8-16 11/8 /2-13 11/4 /2-13 11/4 /8-11 11/2 /8-11 11/2 /4-10 13/4 11/16 11/4 113/32 19/16 21/4 15/64 15/64 119/64 119/64 131/64 11/16 15/16 111/16 17/8 15/16 11/2 Single Conductor Short Stud Double Conductors Short Stud Blackburn Types Service Entrance Connectors Cat. Conductor Range (AWG) ACSR Copper max. min. max. min. Dimensions (in.) Bolt Head Mechanical Service Entrance Connectors MECHANICAL CONNECTORS 10NPW 6NPW 4NPW 2NPW str. str. str. str. sol. sol. sol. sol. .337 .415 .515 .643 .156 .191 .243 .304 .562 .656 .775 .970 Service entrance connectors with bodies screws high-strength copper alloy; plated Type phosphor bronze washer, plated protect conductor distribute pressure Type used ACSR conductor Slotted head screw Washer Type only Type Type Type Neutral Span Clamp Conductor Range ACSR Cat. Main Main 4/0-4 1/0-6 str.-2 sol. str.-6 sol. combination aerial cable neutral parallel groove connector dead-ending clamp that accommodates four service drops Used situations where house adjacent pole Taps installed later independent existing connections Castings high strength aluminum alloy; hardware galvanized steel; piece construction Other recent searchesU1005-QD - U1005-QD U1005-QD Datasheet SPB-5720G - SPB-5720G SPB-5720G Datasheet RL101FG-107FG - RL101FG-107FG RL101FG-107FG Datasheet P4C164 - P4C164 P4C164 Datasheet P4C164L - P4C164L P4C164L Datasheet OVSPBBCR44 - OVSPBBCR44 OVSPBBCR44 Datasheet OVSPGBCR44 - OVSPGBCR44 OVSPGBCR44 Datasheet OVSPW1BCR44 - OVSPW1BCR44 OVSPW1BCR44 Datasheet HSCH-3206 - HSCH-3206 HSCH-3206 Datasheet HSCH-5019 - HSCH-5019 HSCH-5019 Datasheet BTA316B-800E - BTA316B-800E BTA316B-800E Datasheet AO4458 - AO4458 AO4458 Datasheet AO4458 - AO4458 AO4458 Datasheet AO4458L - AO4458L AO4458L Datasheet
Privacy Policy | Disclaimer |