Fittings Fittings Introduction Thomas Betts Complete Product
Top Searches for this datasheetIntroduction. Tables Specifications Rigid Metal Conduit/Intermediate Metal Conduit Fittings A4-A38 Conduit Outlet Bodies A39-A40 Form Form Conduit Outlet Bodies A41-A49 Mogul Conduit Outlet Bodies A50-A51 Aluminum Mogul Conduit Outlet Bodies A52-A53 FS/FD Cast Device Boxes Covers. A54-A56 FS/FD Aluminum Device Boxes Covers A57-A65 Conduit Expansion Coupling. A66-A67 Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof A68-A69 Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof A70-A79 Conduit Outlet Bodies Explosion-Proof, Dust-Ignition-Proof A80-A81 Conduit Outlet Elbows Explosion-Proof, Dust-Ignition-Proof PLG, Reducers, Plugs Adapters Explosion-Proof, Dust-Ignition-Proof Three-Piece Couplings Explosion-Proof, Dust-Ignition-Proof A84-A85 Aluminum Three-Piece Couplings Explosion-Proof, Dust-Ignition-Proof A86-A87 Elbows Explosion-Proof, Dust-Ignition-Proof Flexible Couplings Explosion-Proof, Dust-Ignition-Proof Sealing Fittings Explosion-Proof, Dust-Ignition-Proof A90-A92 Aluminum Sealing Fittings Explosion-Proof, Dust-Ignition-Proof A93-A96 Kopr ShieldCompound. Metal Clad Cable Termination Fittings A98-A108 Electrical Metallic Tubing (EMT) Fittings A109-A114 Liquidtight Flexible Metal Conduit Fittings A115-A131 XTRAFLEX® System Conduit, Tubing, Fittings Nonmetallic Liquidtight Conduit Material PVC. A132-A139 Flexible Cords Cable Fittings A140-A151 Flexible Cords Cable Fittings Non-Metallic A152-A153 WireMesh Grips A154 Non-Metallic Cable Glands. A155 Service Entrance Cable Fittings A156-A160 Armored Cable Flexible Metal Fittings Conduit A161-A169 Non-Metallic Sheathed Cable Fittings. A170-A175 Conduit Dimensional Data A176-A178 Fittings Fittings Introduction Thomas Betts Complete Product Line Since turn century, Thomas Betts been recognized leader electrical fittings. Industry standards such Chase® Nipples Erickson® Couplings were introduced Thomas Betts still registered trademarks. This leadership continues. Here's why. Innovative Designs real test product design electrical fittings lies areas: Job-suited installation life reliability. Thomas Betts Fittings provide both because listen. listen problems suggestions from field. Most products this section result from good suggestions knowledgeable electrical people. Many were customer specials solve particular installation performance problems. benefit from their experience. Approvals Listings Electrical raceways require accessory fittings that provide mechanical strength, ground continuity, environmental integrity system. raceways have been introduced, Thomas Betts engineers have designed fittings which meet requirements National Electrical Code well listing requirements Underwriters' Laboratories Canadian Standards Association. Thomas Betts Fittings with confidence. High Performance Products Quality performance result when engineering design skills combined with manufacturing technologies required produce them. Thomas Betts Fittings this section produced from many materials many manufacturing methods, each carefully selected suitability. This combination gives reliable performance expect from Thomas Betts Raceway Fittings. Lower Installed Cost function purchase cost, availability, installation advantage, performance. Lower installed cost comes every carton Thomas Betts Raceway Fittings. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Tables Specifications Rigid Metal Conduit/Intermediate Metal Conduit Fittings DURA-PLATEFinish Corrosion Resistant Finish Protects Fittings Harsh Environments Comparative Resistance Salt Spray ASB-117 HOURS SALT SPRAY DURA-PLATECorrosion Resistant Fittings Fittings Standard Zinc Plating Mechanical Galvanize Indicates hours white corrosion Indicates hours first apperance rust DURA-PLATECorrosion Resistant Fittings have plating process that provides excellent corrosion resistance threaded steel malleable iron fittings harsh environments. DURA-PLATECorrosion Resistant Fittings utilize electro-plating process which insures uniform thickness protective material over entire part. Conventional coatings deposit uncontrolled build-up material part, especially threaded areas. This excess build-up must removed allow mating parts function. process removing this build-up threads turn damages coating compromises effectiveness protection. additional drawback coating lower ductility alloyed interface layer which formed during process which cause spalling item deformed after coating. addition uniformity coat- ing, distinctive gold color plating allows immediate recognition that part been prepared exposure harsh environments confirms extra protection visual inspection. DURA-PLATECorrosion Resistant Fittings have been subjected salt spray tests conducted according ASSpecification B-117. results Corrosion Resistant Fittings tests, along with galvanized parts, appears below: Ordering Information prefix "040-" standard catalog number; example 5332 with DURA-PLATECorrosion Resistant Fittings protection would ordered "040-5332". Check catalog numbers stock. Allow weeks delivery, nonstock items. price standard item. Minimum order standard package quantity. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Locknuts Application connect externally threaded conduit connector threadless opening enclosure. effectively bond conduit connector enclosure. Features Hardened Steel/Malleable Iron/Copper free Aluminum construction. Tightens without deformation. Locknuts specially designed Provide extended reach clamping thin boxes enclosures. (ii) through protective coating enclosure thereby insuring ground continuity. (iii) Permit tightening from outside. (iv) Prevent loosening under vibration Series provided with hardened cone point screw. Standard Material Series Series thru steel (hardened) thru Malleable Iron screws steel 141AL Series copper-free aluminum Standard Finish Steel Malleable Iron locknuts including Electro Zinc Plated bonding screws Chromate Coated Aluminum locknuts degreased Range through conduit (All threads straight pipe [NPS]) (140 Series) through conduit (106 Series 141AL Series) Series 141AL Series Listed/Certified U.L. (U.L. File E-23018) [catalog numbers 108, 111. Series except catalog number 140.] (LR-2884, LR-4484) Conforms U.L. 514B C22.2 NEMA NFPA 70-1999 (ANSI) Federal Specification replaced A-A-50553 Federal Standard H-28 (Threads) "Case Hardened Locknuts" Case hardened locknuts make fittings faster easier install. Case hardened locknuts slip turn thereby protecting biting edge. Case hardened locknuts bite through paint into enclosure providing excellent continuity ground (typical T&B/Thomas Betts fitting with case hardened locknuts successfully passed minimum fault current 10,000 amps RMS). Case hardened locknuts when assembled intended manner will vibrate loose thereby insuring excellent ground continuity. Series 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Fittings Locknuts Cat. Stl. M.I. 139* 140* 141** 142** Alum. 141AL 142AL 143AL 144AL 145AL 146AL 147AL 148AL 149AL 150AL 151AL 152AL 153AL Size Dimensions (in.) Thickness Steel malleable iron (steel thru Aluminum 624. shape Case hardened locknuts Aluminum locknuts comply with federal standard copper free aluminum; less than copper. Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 Bonding Locknuts Cat. certified. Available with DURA-PLATE Finish. U.L. File E-3060 File Dimensions (in.) Size .125 .140 .170 .170 .170 .187 .375 .375 .438 .438 Thickness Steel malleable iron (steel thru 2"). anywhere ordinary locknut installed insure positive bonding conduit prevent loosening vibration. Also used Service Entrance applications conformance with Code. rigid conduit E.M.T. (thinwall) fittings comply with Federal Specification 408c. Sealing Locknuts Cat. 141SL 142SL 143SL 144SL 145SL 146SL U.L. File E-23018 File 2884 Dimensions (in.) Size 1.140 1.420 1.770 2.281 2.598 3.175 Molded Santoprene Seal Color: Blue Provides positive seal against water oil. with rigid intermediate metal conduits, fittings provide watertight rain tight seal enclosures. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Bonding Grounding Wedges Application effectively bond terminating fitting conduit enclosure. Features Sizes thru equipped with additional bonding screw install bonding jumper where required. added existing installation without disconnecting conductors. Standard Material/Finish size Steel/Electro Zinc Plated thru size Bronze/Tin Plated Range thru conduit Listed/Certified File #E3060 File #638 Conforms U.L. C22.2 NFPA-70 1999 (ANSI) Federal Specification W-F-406 Series 3650 Series 3651 Grounding Wedges Cat. 3650 3651 3652 3653 3654 3655 3656 3657 3658 3659 3661 3662 U.L. File E-3060 Size Especially suited grounding work, equally convenient new, grounding wedges provide grounding without jumper except concentric knockouts. When jumper required, fits under screw grounding wedge. Update existing installations meet code requirements bonding (NEC Sect. 250-72e) without disconnecting wiring. wiring also. Loosen bushing position wedge. Tighten bushing bonding screw. Sealing Rings with Stainless Steel Retainer Cat. Sealing Ring Santoprene Thermoplastic Rubber Conduit Size Dimensions (in.) These sealing rings provide liquid tight, dust tight, seal fitting enclosures. 5302 5303 5304 5305 5306 5307 5308 5309 5311 NEMA U.L. File E-13938 File 2884 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Mounting screw with nylon locking patch cone point lock bushing securely place. Integral grounding enhances ground continuity. Added ground wire range taking reduces inventory. Accepts copper aluminum ground wires. Insulating nylon surface 150°C rated covers bushing, including corners. Angle screw improves accessibility when securing grounding wire. Fittings Blackjack Grounding Bushing Innovative design makes installation quicker, easier. Blackjack® Grounding Bushing never threaded onto conduit. simply placed position either threaded non-threaded rigid conduit, with grounding perfect position accept grounding wire. Even tight installations. It's simple one, two, three. Compare installation with conventional bushings that must threaded onto conduit. tight areas, have remove grounding lug, keep with loose parts, then reattach lug. Then still have twist turn bushing position accept grounding wire. Blackjack bushing does away with these needless delays good, making ideal grounding bushing. only logical choice small spaces, corners, multiple conduit runs. And, because grounding integral part bushing, designed fall lost. Innovative design improves performance. Blackjack® bushing provides superior ground continuity. Insulator surface features rounded design reduce drag prevent abrasion during wire pulling. Cast "threads" opposite mounting screw tighten during installation. threaded non-threaded rigid conduits. Blackjack bushing's nylon locking patch designed prevent screw from loosening vibration. Reduce inventory. Because Blackjack Grounding Bushing designed threaded non-threaded conduits, ground lugs designed handle extended range, number parts inventory reduced twothirds without losing application coverage. design Blackjack bushing integral, cast-on grounding better ground continuity. This means that Blackjack bushing stands intense loads. Secure grip forms lasting bond. Blackjack bushing's conepoint mounting screw bites securely into both Blackjack Conduit Grounding Bushing Screw: 14-4: Slotted 14-2/0: Slotted 6-4/0: Internal Drive Standard Material/Finish Body: Malleable Iron Aluminum Mounting Screw: 2"-2") Stainless Steel, 2"-6") Brass Screw: Stainless Steel Finish: Zinc Plated Mechanical Galvanized Range Conduit: thru threaded threadless rigid/IMC Wire Range: CU/AL Listed/Certified File #E3060 File #LR2884 Conforms U.L. 514B U.L. C22.2 C22.2 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Blackjack Grounding Bushing technical information Nylon Insulator (150oC) Mounting Screw Screw 14-4: Slotted 14-2/0: Slotted 6-4/0: Internal drive Throat I.D. Threaded Threadless Rigid Conduit. Zinc Plated Malleable Iron BG050-14-20 BG050-14-4 BG075-14-20 BG075-14-4 BG100-14-20 BG100-14-4 BG125-14-20 BG150-14-20 BG200-14-20 BG250-14-20 BG250-6-40 BG300-14-20 BG300-6-40 BG350-14-20 BG350-6-40 BG400-14-20 BG400-6-40 BG500-14-20 BG500-6-40 BG600-14-20 BG600-6-40 Suggested Specifications Aluminum BGA050-14-20 BGA050-14-4 BGA075-14-20 BGA075-14-4 BGA100-14-20 BGA100-14-4 BGA125-14-20 BGA150-14-20 BGA200-14-20 BGA250-14-20 BGA250-6-40 BGA300-14-20 BGA300-6-40 BGA350-14-20 BGA350-6-40 BGA400-14-20 BGA400-6-40 BGA500-14-20 BGA500-6-40 BGA600-14-20 BGAT600-6-40 Conduit Size Max. 1.251 1.251 1.533 1.533 1.783 1.783 2.220 2.470 2.830 3.418 3.418 4.042 4.042 4.542 4.542 5.042 5.042 6.136 6.136 7.199 7.199 Min. Throat I.D. .569 .569 .772 .772 .993 .993 1.319 1.553 2.010 2.412 2.412 3.022 3.022 3.491 3.491 3.975 3.975 4.991 4.991 6.009 6.009 Max. 1.181 1.027 1.221 1.030 1.181 1.027 1.181 1.181 1.181 1.181 1.524 1.181 1.524 1.181 1.524 1.181 1.524 1.181 1.524 1.181 1.524 Max. 2.134 1.940 2.414 2.168 2.581 2.368 2.987 3.236 3.766 4.341 4.526 4.966 5.139 5.467 5.639 5.966 6.139 7.045 7.207 8.087 8.409 Max. .696 .696 .696 .696 .696 .696 .759 .696 .696 .978 .978 .978 .978 .978 .978 .978 .978 .978 .978 .978 .978 Wire Range 14-2/0 14-4 14-2/0 14-4 14-2/0 14-4 14-2/0 14-2/0 14-2/0 14-2/0 6-4/0 14-2/0 6-4/0 14-2/0 6-4/0 14-2/0 6-4/0 14-2/0 6-4/0 14-2/0 6-4/0 Insulated grounding bonding bushing (Series BG050-BG600) Where code requires bonding grounding single multiple metal conduits, positive bonding grounding metal conduit box, enclosure auxiliary gutter, conduit shall equipped with insulated metallic grounding bonding bushing series BG050-14-20 manufactured Thomas Betts. Grounding bonding bushings used shall approved purpose Shall malleable iron/steel/aluminum construction adequately protected against corrosion. (ii) Bushing insulator shall listed certified 150°C/302°F application with flammability rating 94V-O. Insulator must positively locked place. Please consult factory mechanically galvanized. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Threaded Insulated Grounding Bushing Application quick installation bonding jumper multiple metal conduits (Rigid IMC). Designed bush conductors prevent insulation damage. Lay-In Fittings Insulator rated 150°C/302°F application. Standard Material/Finish: Body Electro zinc plated Aluminum/tin plated Insulator Thermoplastic 150°C/302°F Application with 94V-0 flammability Wire Clamping Screw Insulator Screw (one) Bushing Casting 3870 Series Features Ease installation, design. Cast malleable iron body designed lock insulator place within body reducing common assembly problem resulting dislodging insulator. Threaded Insulated Grounding Bushing Cat. 3870-TB 3861 3871-TB 3862 3872 3882 3873 3883 3874 3884 3875 3889 3876 3886 3993 3877 3887 3994 3878 3863 3995 3879 3864 3996 3880 3865 3998 3881 3866 3999 Conduit Size Bushing Dia. 1.125 1.125 1.420 1.420 1.770 1.770 2.190 2.190 2.468 2.468 3.031 3.031 3.516 3.516 3.516 4.234 4.234 4.234 4.781 4.781 4.781 5.328 5.328 5.328 6.328 6.328 6.328 7.406 7.406 7.406 Throat Dia. .560 .560 .742 .742 .944 .944 1.242 1.242 1.449 1.449 1.860 1.860 2.222 2.222 2.222 2.761 2.761 2.761 3.193 3.193 3.193 3.623 3.623 3.623 4.542 4.542 4.542 5.458 5.458 5.458 Length 1.310 1.675 1.310 1.675 1.310 1.675 1.310 1.675 1.310 1.675 1.310 1.675 1.310 1.675 2.230 1.310 1.675 2.230 1.310 1.675 2.230 1.310 1.675 2.230 1.310 1.675 2.230 1.310 1.675 2.230 Swing Radius 1.212 1.402 1.360 1.550 1.535 1.725 1.745 1.935 1.884 2.074 2.165 2.355 2.408 2.598 2.928 2.767 2.957 3.287 3.040 3.230 3.560 3.314 3.504 3.834 3.814 4.000 4.334 4.353 4.543 4.875 Bushing Height .657 .657 .660 .660 .735 .735 .735 .735 .770 .770 .770 .770 .940 .940 .940 .975 .975 .975 .975 .975 .975 .980 .980 .980 .985 .985 .985 1.200 1.200 1.200 Wire Range CU/AL 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 Temperature rating 150°C. Meets Coast Guard Regulation CG293 Available with DURA-PLATE® Finish. mechanically galvanized iron, suffix-MG. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Insulated Throat Fittings Cat. 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 Dimensions (in.) Alum. 1222AL 1223AL 1224AL 1225AL 1226AL 1227AL 1228AL 1229AL 1230AL 1231AL 1232AL 586AL 587AL Size Nylon insulated metallic bushings Steel malleable iron (Steel thru National Electric Code paragraph 373-6C calls protection ungrounded conductors means smoothly rounded insulating surfaces entrance raceways, pull boxes, junction boxes, etc. insulated throat fittings, recognizable distinctive trademarked blue insulating liner throat, meet surpass this Code requirement. addition, insulated fittings also reduce wire pulling effort much 50%. Temperature rating 105°C. Certified Catalog series 1222 thru 1232, available aluminum. suffix Cat. aluminum series certified. Metallic Bushings Cat. Stl. M.I. 125-TB 130-TB 131-TB 132-TB 133-TB 134-TB Alum. 122AL 123AL* 124AL** 125AL 126AL 127AL 128AL 129AL 130AL 131AL 133AL 134AL Size Dimension (in.) Aluminum, steel malleable iron (steel thru 2"). Smoothly rounded shoulder covers conduit: broad flange covers knockout hole. High ribs make tightening easy with fingers with wrench. size, formed steel, have extra smooth shoulders. Locknut-type base gives improved bonding resists loosening under conditions vibration. U.L. Listed Certified Certified Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 Plastic Insulating Bushings Cat. 222-TB 223-TB 225-TB 228-TB 229-TB 230-TB Flame retardant. U.L. Rated 94V-1. Dimensions (in.) Size Plastic Insulating Bushings Impact resistant plastic insulation. These bushings have ribs gripping when installing. Perfect threads easy thread U.L. Listed 105°C. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Insulating Bushing (For Threadless Rigid Conduit Intermediate Metal Conduit) Application When assembled threadless conduit, provides well rounded insulating surface over which conductors pulled which conductors bear while service. Features Designed popped onto, bush, conduit end. Fast, easy installation without screws. High impact thermoplastic construction. Standard Material High impact thermoplastic listed 105°C (221°F) application. Flammability Classification V-1. Using flat surface standard utility tool such electricians pliers hammer with block wood larger sizes), strike bushing surface using series light blows until conduit rests against bushing throat conduit stop. Fittings Standard Finish molded. Range through conduit Listed U.L. (U.L. File E-13938) (LR-2884, LR-4484) Conforms U.L. 514B NFPA 70-1999 (ANSI) TRIB50 Series conduit squarely. Remove sharp edges burrs inside outside diameters reaming filing. Slip pop-on bushing over conduit. Insulated Metallic Bushing Cat. TRIB-50 TRIB-75 TRIB-100 TRIB-125 TRIB-150 TRIB-200 TRIB-250 TRIB-300 TRIB-350 TRIB-400 Dimensions (in.) Size Pop-on Bushing Threadless Rigid (and IMC) Insulating Bushings. I.M.C. sizes thru U.L. Rated flame retardant 94V-1. U.L. File E-13938 File 2884 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Knockout Bushings Application bush knockout openings metal boxes enclosures. Features piece construction designed snap place. High impact strength self extinguishing non-dripping (per U.L. thermoplastic construction. Standard Material Thermoplastic rated 105°C (221°F) application. Standard Finish molded. Range .875" through 2.469" nominal diameter knockout opening through trade size knockouts). Wall thickness enclosure .095" max. trade size. .140" max. through trade size. Listed/Certified U.L. (U.L. File E-3803) (LR-589, LR-4484) Conforms U.L. 514B C22.2 NFPA 70-1999 (ANSI) 3210 Series Knockout Bushing One-piece knockout bushing quickly snaps into outlet box, switch box, other enclosure left vacant wiring modifications maintenance changes. Provides smooth, rounded insulation surface easy wire pulling. Easily installed hand, they available through knockouts. U.L. Listed 105°C. High impact thermoplastic. Cat. 3210 3211 3212 3213 3214 3215 Size* .875 1.109 1.375 1.734 1.984 2.469 Dimension (in.) .360 .360 .360 .400 .520 .520 U.L. NEMA standards. Refer "KNOCKOUT" table page A14. Oxygen index >28° U.L. 94V-1 U.L. File E-3803 File 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Fittings Capped Bushings Cat. 1460 1461 1462 1463 1464 1465 U.L. File E-23018 File 2884 Dimension (in.) Size Makes workmanlike seal against grit, plaster, mischief. Removable with pliers. shown through steel: malleable iron. INSULINER® Sleeves Cat. Oxygen index >28° U.L. File E-23018 File Dimension (in.) Size .025 .025 .025 .030 .030 .030 .040 .040 .055 .055 .070 .070 Slip over wires insert into bushing snaps into place High dielectric nylon, 105°C. insuliner sleeve snapped into regular bushing makes U.L. Listed insulated bushing. standard rigid conduit, E.M.T. (thinwall conduit) standard bushed outlet. Especially suitable with flexible metallic conduit. Converts ordinary bushing code approved insulated bushing without disturbing wiring. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Knockout Plugs Application plug unused knockout openings enclosure. Features piece construction designed snap place. High impact strength self-extinguishing non-dripping (per U.L.-94) thermoplastic construction. Standard Material Thermoplastic rated 105°C (221°F) application. Standard Finish molded. Range .875" through 2.469" Nominal Diameter Knockout opening through trade size knockouts). Wall thickness enclosure .095" max. trade size .140" max. through trade size. Listed/Certified U.L. (U.L. FILE E13938) (LR589) Conforms U.L. 514B NFPA 70-1999 (ANSI) 1451 Series Knock-out Plugs Cat. Dimensions (in.) Size 1.060 1.300 1.590 1.860 2.240 2.740 .400 .400 .400 .450 .570 .570 105°C rated U.L. Made from flame retardant, non-dripping thermoplastic. 1451 1452 1453 1454 1455 1456 Wall thickness electrical .095 max. Meets Coast Guard Regulation CB293. U.L. File E-13938 File 4484 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Plug, Conduit, Connectors (Push Penny Plugs) Application plug open conduit connector order prevent ingress trash, dirt moisture during construction remodeling. Features Wide range application; used with rigid metal conduit, intermediate metal conduit, electrical metallic tubing, connnectors bushings. Designed stand normal handling functionally unaffected moisture. Standard Material Polyethylene Standard Finish molded Listed/Certified (LR2884, LR4484) Conforms U.L. 514B C22.2 NFPA 70-1999 (ANSI) NEMA Fittings Push-Penny® Plugs Cat. 1470 1471 1472 1473 1474 1475 1476* 1477* 1478* 1479* Certified File 2884 applicable Size Economically seal grout plaster from fitting raceway conforming dimensional tolerances. Made flexible plastic, they push into place held fast pressure against internal surface fitting raceway. Eliminates need separate capped bushing steel penny bushing. Pennies Steel Cat. 815-TB U.L. applicable File 2884 Size penny under bushing will seal conduit during construction. Made bushing. Completely salvageable. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Nipple (CHASE Nipple) Application effectively bush factory fieldpunched, cut, drilled holes metal boxes enclosures. couple boxes back-to-back. Features Rugged construction. Insulator curled over Bush conductors entering/leaving angle. Reduce wire pull effort. Protect threads against damage handling. Standard Material 1942 Series Body.d" Steel through Malleable Iron Insulator .Nylon 842AL Series Copper free Aluminum Standard Finish 1942 Series.Electro Zinc Plated Chromate Coated 842AL Series.Degreased Range 1942 842AL Series through threads straight pipe (NPS) Listed/Certified U.L. [All except Catalog 842AL, 844AL 845AL] (U.L. File E-23018) (LR-2884, LR-4484) Conforms U.L. 514B C22.2 Federal Specification W-F-408 NFPA 70-1999 (ANSI) NEMA Federal Standard H-28 (Threads) 1942 Series 842AL Series (Non Insulated) 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Fittings CHASE® Nipples Cat. Stl. M.I. Alum. 842ALTB 843ALTB 844AL 845AL 846AL 847AL 848AL 849AL 850AL 851AL 853AL 854AL Size Dimensions (in.) Steel malleable iron aluminum. 841TB 842TB 843TB Listed Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 CHASE® Nipples Nylon Insulated Cat. 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1953 1954 U.L. File E-23018 File 2884 Dimensions (in.) Size Steel malleable iron aluminum. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Predetermined Compression Threaded Hubs (Bullet® Hubs) (For Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit) Application connect threaded metal conduit (ferrous rigid/non-ferrous rigid/PVC coated/or intermediate metal) threadless opening enclosure outdoors indoor location exposed continuous intermittent moisture. positively bond conduit enclosure. (ii) Class Groups Class locations 18-202; 18252; 18-302; 18-352. coated Series Protects connector from extremely corrosive surroundings without affecting integrity electrical grounding path (F). (ii) Provided with overlapping sleeve additional seal (G). National Electrical Code states that, "Where practicable, dissimilar metals contact anywhere system shall avoided eliminate possibility galvanic action", only exceptions Aluminum fittings enclosures, permitted used with steel conduit. Joint Industrial Council (JIC) Electrical Standards also forbid dissimilar metals contact same reason require that fittings metal conduit malleable iron ductile iron have impact strength comparable that conduit. "Copper Free Aluminum" Copper free aluminum castings fittings have maximum 0.4% copper. most detrimental effect higher percentage copper aluminum base alloy decrease corrosion resistance. Series 370AL Series Series Features Rugged steel/malleable iron/copper free aluminum construction. Tapered internal threads watertight/dust tight union (A). Threads relieved prevent bottoming conduit ensuring sound assembly (B). Recessed sealing ring end. Sealing ring captivated (C). Hardened steel/malleable iron/copper free aluminum locknuts designed provide high quality ground continuity; extended reach locknut permits clamping thin boxes enclosures (D). Insulated throat, insulates conductors, prevents abrasion thinning conductor insulation, reduces wire pull effort (E). Suitable hazardous location following: Class Division Class Division Class Division N.E.C. 501-4 (b); 502-4 503-3 (a). 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Threaded Hubs (Bullet Hubs) (Continued) (For Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit) Fittings Standard Material 370-485 Series Body Locknut Screws Ring Insulator Coating thru Steel 11/4" thru Malleable Iron thru Steel (hardened) 21/2" thru Malleable Iron Steel (hardened) Buna Nylon 370AL Copper-Free Aluminum thru Steel (hardened) 21/2" thru Copper Free Aluminum Standard Finish Series Locknuts Screws 370AL Series Series Electro Zinc Plated Cast Outside. Electro Zinc Chromate Coated Plated Chromate Coated Inside Ferrous Locknuts Electro Zinc Plated Chromate Coated Electro Zinc Plated Chromate Coated Range Series thru Conduit 370AL Series thru Conduit threads straight pipe female threads taper pipe (NPT) Listed/Certified U.L. (U.L. File E-23018) (LR-637, LR-23086) Conforms U.L. 514B C22.2 NFPA 70-1999 NEMA FB-1 EGP1; Federal Specification W-F-408 Federal Standard H-28 (Threads) 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Steel/Malleable Iron Aluminum Connectors* Cat. Stl. M.I. Alum.** 370AL 371AL 372AL 373AL 374AL 375AL 376AL 377AL 378AL 379AL Size Dimensions (in.) Wall Thk. (max.) Nylon insulated Aluminum, steel, malleable iron (steel through 1"). With Neoprene Ring provides watertight threaded enclosures. U.L. Listed 105°C. Suitable hazardous locations Class Div. Class Div. Class III, Div. where general purpose equipment specifically permitted Section 500-2(a). Aluminum available with insulated throat. U.L. Listed rain tight Certified watertight dust tight Available with DURA-PLATE® Finish. U.L. File E-23018 Stl.: File 2284 AL.: File 0637 Coated Rigid Conduit Cat. Dimensions (in.) Conduit Size Steel malleable iron (steel thru 4"). LOCKNUT THREAD PLASTIC COATING Suitable hazardous locations Class Div. Class Div. Class III, Div. 501-4(b); 502-4(a) (2); 503-3(a) where general purpose equipment specifically permitted Section 500-2(a). INSULATOR SEALING RING 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Spacing Chart Bullet® Hubs Center Center Spacing Conduit Sizes Fittings Min. Space from Center Bullet® Wall Diameters (min.) BULLET® Connectors Nylon Insulated Cat. 404-TB 406-TB 410-TB Size (in.) Packaging Description Carton Std. Steel malleable iron (steel through inch). Used with neoprene ring provide watertight* threaded enclosures. Supplied with series bonding locknut. Temperature rating: 105°C. *CSA LR2884. Certified watertight dust tight. Spacing Chart Bullet® Sealing Hubs Center Center Spacing Conduit Sizes Min. Space from Center Bullet® Wall Diameters (min.) 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Never before single like this one. Designed unequalled performance. innovative engineering T&B® will, quite simply, raise your performance expectations threaded hubs. Locknut Design with peripheral slots hexagonal/angled spline spaced every enables easy application torque with wrench hammer screwdriver. (See Figures Fig. Fig. Sealing Ring Groove with innovative profile outperforms standard ring design. Sealing ring captivated place before installation resists buckling slipping during installation. seal groove designed optimum compression sealing ring. sealing ring designed provide complete 360° seal, even when conduit perpendicular with enclosure. (See Figure Sharper Deeper Teeth locknut body designed more penetrating bite improved bonding enclosure. Hexagonal/Splined Body Design fast, easy installation with wrench hammer screwdriver. Precision Machined Tapered Threads designed create watertight union. Insulated Throat molded from 105° rated thermoplastic with flammability rating V-O. Fig. Cat. H050-TB H075-TB H100-TB H125-TB H150-TB H200-TB H250-TB H300-TB H350-TB H400-TB H500-TB H600-TB Material Trade Size Locknut: Insulating Throat: Dia. Max. Panel Thickness Throat Dia. Throat Dia. zinc copper free aluminum thermoplastic temp. rating 105°C Flammability Rating: 94V-0 Sealing Ring Nitrile (BUNA "N") Aluminum Hubs suffix (i.e. H050A). Chrome Plated Hubs suffix (i.e. H050CP). Stainless Steel Hubs suffix GRSST (i.e. H050GRSST). through only.) Meets NEMA sealing requirements NEMA enclosures. U.L. Listed Certified. Certified hazardous locations Class Groups E.F.G. Class III. U.L. File E-23018 File 4484 Chrome Plated Hubs (suffix-"CP") rated NEMA 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Grounding Cat. H050GR-TB H075GR-TB H100GR-TB H125GR-TB H150GR-TB H200GR-TB H250GR-TB H300GR-TB H350GR-TB H400GR-TB H500GR-TB H600GR-TB Material Trade Size Locknut: Insulating Throat: Dia. Max. Panel Thickness Throat Dia. Fittings Throat Dia. zinc copper free aluminum thermoplastic temp. rating 105°C Flammability Rating: 94V-0 Sealing Ring Nitrile (BUNA "N") Aluminum Hubs suffix (i.e. H050A). Chrome Plated Hubs suffix (i.e. H050CP). Stainless Steel Hubs suffix GRSST (i.e. H050GRSST). through only.) Meets NEMA sealing requirements NEMA enclosures. U.L. Listed Certified. Certified hazardous locations Class Groups E.F.G. Class III. U.L. File E-23018 File 4484 Chrome Plated Hubs (suffix-"CP") rated NEMA Grounding Bonding Locknut Cat. L050GR L075GR L100GR L125GR L150GR L200GR L250GR L300GR L350GR L400GR L500GR L600GR Trade Size Dia. Height Ground Screw #10-32 #10-32 #10-32 b-20 b-20 b-20 b-20 b-20 b-20 b-20 c-16 c-16 Max. Conductor Size Material Locknut: zinc copper free aluminum U.L. File E-3060 Aluminum Locknuts suffix (i.e. L050GRA) File 4484 Chrome Plated Locknuts suffix (i.e. L050CP). Stainless Steel Locknuts suffix through only.) Centerline Spacing Chart Conduit Trade Size Grounding Locknut Hubs Nearest Obstruction Center 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Bulkhead Fittings Across Flats Diameter Bulkhead Fitting Cat. H050BHD H075BHD H100BHD H125BHD H150BHD H200BHD H250BHD H300BHD H350BHD H400BHD H500BHD H600BHD Trade Size Thread Nipple Included Thru Bulkhead Fitting Height Cat. H050TBF H075TBF H100TBF H125TBF H150TBF H200TBF Trade Size Thru Bulkhead Cat. H050TBH H075TBH H100TBH H125TBH H150TBH H200TBH Trade Size Material Thread d"-14 f"-14 1"-11d 1b"-11d 1d"-11d 2"-11d 2d"-8 3"-8 3d"-8 4"-8 5"-8 6"-8 Hub, Body Locknut: Insulating Throat: Height Diameter Across Flats Trade Size Sealing Ring Aluminum Bulkheads suffix Chrome Plated Bulkheads suffix Meets NEMA sealing requirements NEMA enclosures. Certified hazardous locations Class Groups E.F.G. Class III. U.L. File E-3060 File 4484 zinc copper free aluminum Thermoplastic temp. rating 105°C Flammability Rating: 94V-0 Nitrile (BUNA "N") 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Fittings Offset Reducers Height Cat. H150-H075ORGR H150-H100ORGR H150-H125ORGR H250-H200ORGR Trade Size 1d"-f" 1s"-1" 1s"-1b" 2d"-2" Height Dia. Dia. Dia. Dia. Material Offset Reducer Locknut: Insulating Throat: Sealing Ring Aluminum Offset Reducer suffix Chrome Plated Offset Reducer suffix Meets NEMA sealing requirements NEMA enclosures. Certified hazardous locations Class Groups E.F.G. Class III. U.L. File E-3060 File 4484 Zinc copper free aluminum Thermoplastic Temp. Rating 105°C Flammability Rating 94V-0 Nitrile (BUNA "N") Capoffs Cat. Height Trade Size Height Diameter Capoff Dia. H050CAP H075CAP H100CAP H125CAP H150CAP H200CAP H250CAP H300CAP H350CAP H400CAP H500CAP H600CAP Material Capoff Locknut: Insulating Throat: Sealing Ring Aluminum Capoff suffix Chrome Plated Capoff suffix Meets NEMA sealing requirements NEMA enclosures. Certified hazardous locations Class Groups E.F.G. Class III. U.L. File E-3060 File 4484 zinc copper free aluminum Thermoplastic temp. rating 105°C Flammability Rating 94V-0 Nitrile (BUNA "N") 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Threadless Connector/Coupling (For Threadless Rigid Metal Conduit Intermediate Metal Conduit) 8123 Series Application connect effectively bond threadless rigid metal conduit/intermediate metal conduit enclosure, couple ends threadless conduit. Features Steel/Malleable Iron Construction. Case hardened ring bites into conduit high quality continuity grip. Nylon insulator firmly secured place protects conductors reduces wire pulling effort much 50%; prevents thread damage handling. Case hardened steel locknut malleable iron locknut designed provide positive bond. Suitable concrete tight application. Capable carrying ground fault currents 10,000 amps (1/2" through 11/2" size) 20,000 amps above sizes). .duration current cycles. Listed/Certified U.L. (U.L. File E-23018) (LR-2884, LR-4484) Standard Material Nut, Gland. Steel Malleable Iron Body Malleable Iron Ring. Steel (case hardened) Insulator. Nylon Locknut thru Steel (hardened) thru Malleable Iron Standard Finish Electro Zinc Plated Chromate Coated Range 8123 8120 Series through Size Conduit 8130 Series through Size Conduit threads Straight Pipe (NPS) Conforms U.L. 514B C22.2 NFPA 70-1999 (ANSI) NEMA Federal Specification W-F-408 Federal Standard H-28 (Threads) 8130 Series 8120 Series 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Fittings Nylon Insulated Threadless Connectors Cat. Nylon Insul. 8123 8223 8323 8423 8523 8623 8723-TB 8823 8853 8973 NonInsul. 8121 8221 8321 8421 8521 8621 8721 8821 8851 8971 Conduit Size Dimensions (in.) split steel ring with diagonal serrations grips conduit bites into positive ground. Makes permanent connection eliminates need cutting thread conduit. Insulation helps guarantee continuity service with protection conductor critical point connector bushing. Malleable iron construction. Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 Threadless Couplings Cat. 8120 8220 8320 8420 8520 8620 8720 8820 8850 8970 Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 Dimensions (in.) Size Eliminate conduit threading. Tightened with wrench they make U.L. Listed Certified concrete-tight connection. Malleable iron. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Threadless Short Elbows Nylon Insulated Cat. 8130 8131 Dimensions (in.) Size Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 Ideal entering enclosure conduit body right angles. Eliminates need thread conduit. with straight couplings, this connector makes concrete-tight connection. Malleable iron. Threadless Short Elbows Cat. 8030 8031 Dimensions (in.) Size This elbow advantages insulated short elbow except insulation. Malleable iron. Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Screw Connector/Coupling (For Threadless Rigid Metal Conduit Intermediate Metal Conduit) Application connect effectively bond threadless rigid metal conduit intermediate metal conduit enclosure couple ends threadless conduit. Features Thickwall steel malleable iron body. Hardened head point screw provide high quality bond. Screw captivated, will vibrate loose. Nylon insulated throat meets exceeds code requirements bushing: Prevents thinning insulation. (ii) Reduces installation effort. (iii) Prevents first thread damage. Coupling provided with positive center stop. Suitable concrete tight application. Capable carrying ground fault currents 10,000 amps through size) 20,000 amps above sizes). Standard Material Body.d" thru Steel thru Malleable Iron Locknut thru Steel (hardened) thru Malleable Iron Screw .Steel (hardened) Insulator .Nylon Standard Finish Electro Zinc Plated Chromate Coated Listed/Certified U.L. (U.L. File E-23018) (LR-2884, LR-4484) Conforms U.L. 514B C22.2 NFPA 70-1999 (ANSI) NEMA Federal Specification W-F-408 Federal Standard H-28 (Threads) Fittings 8125 Series 8124 Series 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Insulated Set-Screw Connector Cat. 8125 8225 8325 8425 8525 8625-TB 8725-TB 8825 8855 8975 Conduit Size Dimensions (in.) Eliminate conduit threading with these screw connectors. Captive head screws tighten down onto conduit positive holding strength ground. connectors furnished with insulated throats reducing wire pulling effort much 50%. Approved concrete tight. Sizes d"-2" made steel. Sizes 2d"-4" malleable iron. Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 Screw Coupling Cat. 8124 8224 8324-TB 8424 8524 8624 8724 8824-TB 8854 8974 Conduit Size Dimension (in.) Eliminate need threading conduit ends when joining rigid conduit with these screw couplings. Captive head screws provide positive holding strength ground continuity. Approved concrete tight. Sizes d"-2" made steel; sizes 2d"-4" malleable iron. Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Fittings Bushed Elbows Cat. 460-TB 461TB Available with DURA-PLATE® Finish. U.L. File 23018 File 2884 Dimension (in.) Size non-insulated elbow smoothly rounded shoulders protect conductor insulation. Malleable iron. Short Elbows Nylon Insulated Cat. 4290 4291 4292 4293 4294 4295 Available with DURA-PLATE® Finish. U.L. CSA. Dimension (in.) Size integral insulation insulated elbow guarantee that bushing every fitting will smooth. Malleable iron. Short Elbows Cat. 4250 4251 4252 4253 4254 4255 Available with DURA-PLATE® Finish. U.L. File #E-23018 File Dimension (in.) Size When insulated elbow desired, non-insulated short elbow should used. Malleable iron. Conduit Nipples Cast Zinc Long Cat. HA-211 HA-212 HA-213 U.L. File E-1275 only Size Offset Nipples Cast Zinc Cat. HO-221 HO-222 HO-223 HO-224 HO-225 HO-226 offset. U.L. File E-1275 Size 2.60" 2.62" 2.68" 2.85" 2.88" 3.19" 1.00" 1.32" 1.51" 1.85" 2.08" 2.71" 3/4" 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Threaded Coupling (Erickson Coupling) (For Threaded Rigid Metal Conduit Intermediate Metal Conduit) Application couple effectively bond threaded ends rigid metal conduit/intermediate metal conduit where neither length conduit rotated. Features Malleable Iron/Steel/Copper free Aluminum Construction. Free fitting threads insure easy assembly. Permits conduit coupling without rotating either conduit. Provides rigid in-line coupling with high quality grounding; will loosen under vibration. Suitable concrete tight application. Capable carrying ground fault currents 10,000 amps through size) 20,000 amps above) (duration fault current cycles) (674 series tested). Standard Material Series Bushing Case .Malleable Iron Ring .Steel Malleable Iron 675AL Series Bushing Case .Aluminum Ring .Aluminum Standard Finish Series: Electro Zinc Plated Chromate Coated 675AL Series: Degreased Range thru Conduit (malleable iron) thru Conduit (aluminum) straight pipe threads (NPS) Listed/Certified U.L. (U.L. File E-23018) (LR-2884, LR-4484) Conforms U.L. 514B C22.2 NEMA NFPA 70-1999 (ANSI) Federal Specification W-F-408 Federal Standard H-28 (Threads) Series 675AL Series ERICKSON® Couplings Cat. 680TB Cat. Alum.* 675AL 676AL 677AL 678AL 679AL 680AL 681AL 682AL 683AL 684AL 685AL 686AL 687AL Dimensions (in.) Size With ERICKSON® coupling, conduit completed when neither conduit turned. conduit also broken without taking down whole run. Conduit joined with ERICKSON® Couplings rigid line vibration will loosen connections. Malleable iron. Copper Free Aluminum. U.L. Listed Certified concrete-tight. U.L. File E-23018 File 2884 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Fittings Panel Connector Extensions Cat. 1440 1441 1442 1443 Dimensions (in.) Size Ideal when longer thread length needed. Will combine with fitting having male thread. Male thread panel connector extension long. Malleable iron. U.L. File E-23018 File 2884 Male Enlargers* Cat. 1245 1246 1244 1247 Dimensions (in.) Size Adapt outlet hole next larger size conduit. Rough ends conduit carefully covered built-in bushing. Malleable iron. items shown this chart suitable hazardous locations where general purpose equipment specifically permitted NEC; Class Div. Class Div. Class III, Div. 501-4(b); 502-4(a)(b); 503-3(a)(b). Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 Female Reducers* Cat. 1250 1261 1251 1262 1263 1252 1253 1254 1255 1256 1257 1258 Dimensions (in.) Size Adapt outlet next smaller size conduit. shoulder makes wrench tightening convenient. Malleable iron. items shown this chart suitable hazardous locations where general purpose equipment specifically permitted NEC; Class Div. Class Div. Class III, Div. 501-4(b); 502-4(a)(b); 503-3(a)(b). Available with DURA-PLATE® Finish. U.L. File E-23018 File 2884 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Threaded Reducers* Cat. Stl. 600TB 601TB 602TB 603TB 604TB U.L. File E-23018 File 2884 Dimension (in.) Alum. 600ALTB 601ALTB 602ALTB 603ALTB 604ALTB 605AL 606AL 607AL 608AL 609AL 610AL 611AL 612AL 613AL 614AL 615AL Size reducing threaded opening conduit bodies female threaded fitting. Smooth, built-in bushing completely covers rough ends conduit. Iron steel construction. Steel thru 606, also 615. Reducing Washers Cat. 3700 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711 3712 3713 3714 3715 3716 3717 3718 U.L. File E-13938 File 2884 Dimensions (in.) Size Washers reduce knockout hole outlet box. Newly designed galvanized steel. These washers, used pairs, interlock form which centers washers conduit knockout. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Conduit Straps (For Rigid Metal Conduit Intermediate Metal Conduit) Application support securely fasten rigid metal conduit intermediate metal supporting surface. Features Rugged malleable iron/copper free aluminum construction snugly fits conduit. Designed prevent accumulation moisture start corrosion vertical conduit (A). Galvanized finish.1275 Series. Copper free aluminum.1276AL Series. Standard Material 1275 Series 1976AL Series Malleable Iron copper free aluminum Fittings Standard Finish 1275 Series 1276AL Series Dipped Cast Galvanized Range 1275 Series 1276AL Series through through conduit conduit Listed/Certified (LR-2884, LR-4484) Conforms C22.2 NFPA 70-1999 (ANSI) 1275 Series 1276AL Series Conduit Strap Conduit Conduit Spacer Supporting Wall Pipe Straps Malleable Iron Aluminum Cat. Mal. Iron 1275 1276 1277 1278 1279 1280 1281 1282* 1283* 1284 1285* 1286 1287 1288 Alum. 1275AL 1276AL 1277AL 1278AL 1279AL 1280AL 1281AL 1282AL 1283AL 1284AL 1285AL 1286AL 1287AL 1288AL Size 11d" Screw Size Designed each size conduit snugly. High reinforcing ribs each side increase strength, reduce weight. Hot-dipped galvanized finish. Malleable iron. used with same size. snap type. U.L. applicable. File 2884 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings Pipe Straps Steel Cat. 1210 1211 1212 1213 1214 1215 1216 snap type. U.L. applicable. File 2884 Conduit Size Screw Size Elongated bolt hole makes alignment easy, even when holes mounting surface center. Snap features. Steel. Corrosion Resistant Coated Rigid Conduit Straps Cat. 1275CR 1276CR 1277CR 1278CR 1279CR 1280CR 1281CR U.L. applicable. Size Bolt Size Dimensions (in.) Malleable iron. Designed each size conduit snugly. High reinforcing ribs each side increase strength, reduce weight. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Rigid Intermediate Metal Conduit Fittings Conduit Spacers (For Rigid Metal Conduit, Intermediate Metal Conduit Electrical Metallic Tubing) 1350 Series 1350AL Series Fittings Application Provides mounting surface conduit where installation requires space between conduit supporting surface. Features Prevents conduit rusting from wall condensation. Spacers stacked atop other facilitating installation eliminating expensive conduit setting (A). Designed cover wide range; marked with accurate size marking proper positioning (B). Galvanized finish 1350 Series. Copper free aluminum alloy, 1350AL Series. Standard Material 1350 Series 1350AL Series Malleable Iron Copper free aluminum Standard Finish 1350 Series 1350AL Series Dipped Cast Galvanized Range through conduit Listed/Certified (LR-2884, LR-4484, LR-4484) Conforms C22.2 NFPA 70-1999 (ANSI) Pipe Spacers Cat. Mal. Iron Alum. 1350AL 1351AL 1352AL 1353AL 1354AL Size 1b"-1d"-2" 2d"-3" 3d"-4" 4d"-5"-6" Screw Size Dimensions (in.) 10l" Used with conduit straps permit space between conduit mounting surface. Eliminates need costly offset-bending conduit possible corrosive moisture traps when conduit mounted directly surface. Hot-dipped galvanized finish, premountable stackable eliminate offsetting. Malleable iron. 1350 1351 1352 1353 1354 Conforms SECT. 300-5-c U.L. applicable. File Nos. 2884 4484 Pipe Spacers coated Cat. Conduit Size d"-f"-1" 1b"-1d"-2" 2d"-3" 3d"-4" 4d"-5"-6" Screw Size Dimensions (in.) Corrosion-resistant, PVC-coated, malleable iron. Pre-mountable, stackable eliminate offsetting. Spacers stacked offsets wall into outlet box. Prevents conduit rusting from wall condensation. Eliminates offsetting conduit. 1350CR 1351CR 1352CR 1353CR 1354CR U.L. applicable. Conforms SECT. 300-5-c. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Rigid Intermediate Metal Conduit Fittings TITE-BITE® Combination Couplings Armored Cable Threaded Rigid Cat. U.L. File E-23018 File 2884 Dimensions (in.) Size one-piece fitting that couples armored cable flexible conduit threaded rigid conduit. Tite-Bite® wedge holds conduit securely with double grip. With Chase nipple this fitting will connect flexible conduit outlet boxes, allowing more wiring space than usual connector. U.L. Listed grounding means under 350-5. Malleable iron. Entrance Ells Cat. 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 U.L. File E-23018 File Nos. 2884 Conduit Size Dimensions (in.) entrance ells mount flat against wall eliminating need offsetting conduit. Designed straight pull either direction carefully bushed, these entrance ells make easy pull heavy wires without damage insulation. Made copper free aluminum. Beam Clamps Adjustable Includes bolts. Steel Cat. 700TB File 2884. Description Fits Flange 2f"-7c" Fits Flange 7"-12" Special Bolt Nuts Conduit Supports Cat. 691TB 692TB 693TB File 2884 Size These supports will flange, tapered straight 5/8" thick. broad hook holds conduit desired angle. Holds standard rigid conduit, E.M.T., I.M.C. Malleable iron. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Conduit Outlet Bodies Conduit Fittings Ordinary Hazardous Locations Thomas Betts offers broad range conduit bodies, conduit boxes, conduit fittings, unions, sealing fittings, drains cable fittings both ordinary hazardous locations. Complete information applications, features, materials, finishes, size range certifications provided following pages. Fittings Conduit Bodies (for ordinary locations) raceway systems provide pull outlets, bends, splices, taps, mounting outlets, etc. FORM neat, compact installation rigid threaded conduit. FORM heavier conductors using rigid threaded conduit. Aluminum rigid threaded conduit installation copper-free Die-Cast aluminum. Thinwall set-screw installation using thinwall conduit. (EMT) (EMT) copper-free aluminum. Mogul larger conduits, spacious, accessible wiring chambers. Conduit Fittings Cast Device Boxes (for ordinary locations) raceway systems accommodate wiring devices, serve pull boxes, provide entrances taps splices. FS/FD Single Double Gang Cast Device Boxes Cast Conduit Outlet Boxes (for hazardous locations) Round cast outlet boxes used with rigid conduit serve pull splice boxes, easy access wiring, housing instruments, apparatus, etc. Conduit Outlet Bodies Reducers, Plugs, Unions (for ordinary hazardous locations) Includes reducers connecting conduit dissimilar dimensions, plugs unused conduit openings hubs, unions threaded conduit systems. Reducers, Plugs Adapters, UNY/UNF Unions Sealing Fittings Drains (for ordinary hazardous locations) Cast fittings used with rigid conduit seal sections from passage vapors, flame gases explosions. Drains provide ventilation breather drain moist locations. EYS/EYD Sealing Fittings Drains Cable Fittings (for ordinary hazardous locations) armored, metal clad, jacketed unjacketed unarmored cables through bulkhead enclosure ordinary hazardous areas. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Form Form Conduit Outlet Bodies Conduit Outlet Bodies Application Conduit Bodies installed conduit systems Connect conduit sections. pull outlets when conductors being installed. Provide easy access splices branch conductors. Make 90-degree bends conduit runs. mounting outlets wiring devices lighting fixtures. Provide access conductors maintenance future system changes. Features Standard features include tapered (NPT) threads, integral bushings protect wire insulation. Form bodies covers interchangeable with other manufacturer's Form bodies covers. Form bodies covers interchangeable with other manufacturer's Form bodies covers. Materials Conduit Bodies (Form Form Sand cast class Gray iron alloy. cast aluminum, copper-free. Covers Sand cast gray iron alloy, stamped sheet steel-stainless steel screws. Gaskets Neoprene Finish Conduit Bodies zinc-plating with aluminum acrylic coating. Covers gray iron zinc-plating with aluminum acrylic coating, stamped steel zinc-plating with clear chromate coating. Compliances Standard: 514A, 514B Fed. Spec: W-C-586D Standard: C22.2 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Form Form Conduit Outlet Bodies Fittings Threaded Rigid Bodies Shape Form Form Threaded Aluminum Aluminum Form Form Threaded Aluminum Aluminum Form Form Threaded Aluminum Aluminum Form Form Threaded Aluminum Aluminum Form Form Threaded Aluminum Aluminum LB17 LB18 ALB1 BLB1 LL17 LL18 ALL1 BLL1 LR17 LR18 ALR1 BLR1 LB27 LB28 ALB2 BLB2 LL27 LL28 ALL2 BLL2 LR27 LR28 ALR2 BLR2 LB37 LB38 ALB3 BLB3 T38-TB LL37 LL38 ALL3 BLL3 LR37 LR38 ALR3 BLR3 1-1/4 LB47 LB448 ALB4 BLB4 T448 C448 LL47 LL448 ALL4 BLL4 LR47 LR448 ALR4 BLR4 Size 1-1/2 LB57 LB58 ALB5 BLB5 C58-TB LL57 LL58 ALL5 BLL5 LR57 LR58 ALR5 BLR5 LB67 LB68 ALB6 BLB6 LL67 LL68 ALL6 BLL6 LR67 LR68 ALR6 BLR6 2-1/2 LB77 LB78 ALB7 BLB7 LB87 LB888 ALB8 BLB8 T88-TB 3-1/2 LB97 LB98 ALB9 BLB9 LB107 LB108 ALB10 BLB10 T107 AT10 C77-TB AC10 LL77 LL78 ALL7 LL87 LL888 ALL8 LL97 ALL9 LL107 ALL10 LR77 LR78 ALR7 LR87 LR888 ALR8 LR97 ALR9 LR107 ALR10 Form Form X448 Form L17-TB Threaded Aluminum ALRL1 Aluminum BLRL1 L27-TB ALRL2 BLRL2 L37-TB ALRL3 BLRL3 L47-TB ALRL4 BLRL4 L57-TB ALRL5 BLRL5 L67-TB ALRL6 BLRL6 Form Threaded Aluminum Form TA17 TA27 TA37 TA47 TA57 TA67 Form TB17-TB TB18 TB27 TB28 TB37 TB38 TB47 TB48 TB57 TB58 TB67 TB68 *Furnished with stamped steel cover 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Form Form Conduit Outlet Bodies Covers Gaskets Shape 1-1/4 Size 1-1/2 2-1/2 3-1/2 Stamped Steel Form Form 170S SCV1 270S SCV2 370S SCV3 470S SCV4 570S SCV4 670S SCV5 870S 870S 970S 970S Gray Iron Form Form 170F 180F 270F 280F 370F 380F 470F 480F 570F 580F 670F 680F 870F 880F 870F 880F 970F 980F 970F 980F Form GASK GASK 581N GKN1 GASK GASK 582N GKN2 GASK GASK 583N GKN3 GASK GASK 584N GKN4 GASK GASK 585N GKN4 GASK GASK 586N GKN5 GASK GASK 588N GKN6 GASK GASK 588N GKN6 GASK GASK 589N GKN7 GASK GASK 589N GKN7 Gasket Form ordering purposes please GASK catalog number. (Example: GASK 571) 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Form Form Conduit Outlet Bodies Fittings Form Cat. LB17 LB27 LB37 LB47 LB57 LB67 LB77 LB87 LB97 LB107 Dimensions (in.) Size 4.60 5.25 6.00 6.45 7.25 8.30 10.55 10.55 12.85 12.85 2.20 2.40 2.65 3.20 3.90 4.45 5.20 5.95 6.70 7.20 1.35 1.65 1.80 2.20 2.45 3.10 4.25 4.25 5.25 5.25 1.15 1.35 1.80 2.05 2.45 3.60 3.60 4.55 4.55 3.20 3.80 4.55 5.00 5.45 6.40 8.40 8.40 10.25 10.25 10.6 18.8 26.4 51.0 102.0 132.0 210.0 243.0 Form Cat. Dimensions (in.) Size 2.219 2.438 2.813 13.0 23.5 45.0 88.0 110.0 110.0 250.0 250.0 Form Form LB18 LB28 LB38 LB48 LB58 LB68 LB78 LB888 LB98 LB108 Threaded Aluminum Cat. ALB1 ALB2 ALB3 ALB4 ALB5 ALB6 ALB7 ALB8 ALB9 ALB10 Dimensions (in.) Size 11.8 32.0 32.0 69.5 190.0 190.0 366.0 366.0 Aluminum Cat. Threaded Aluminum Aluminum BLB1 BLB2 BLB3 BLB4 BLB5 BLB6 BLB7 BLB8 BLB9 BLB10 Dimensions (in.) Size 11.8 32.0 32.0 69.5 190.0 190.0 366.0 366.0 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Form Form Conduit Outlet Bodies Form Cat. T107 Dimensions (in.) Size 5.60 6.20 7.35 7.30 8.60 9.50 12.10 12.10 14.65 14.65 1.80 2.00 2.30 2.30 2.60 3.20 3.65 4.40 4.90 5.40 2.35 2.60 3.10 3.05 3.80 4.25 5.80 5.80 7.05 7.05 1.15 1.35 1.80 2.05 2.45 3.60 3.60 4.55 4.55 3.20 3.80 4.55 5.00 5.45 6.40 8.40 8.40 10.25 10.25 16.9 19.3 27.5 50.0 102.0 132.0 210.0 243.0 Form Form Form Cat. T38-TB T88-TB Dimensions (in.) Size 15.0 24.0 46.5 88.0 110.0 110.0 Threaded Aluminum Cat. AT10 Dimensions (in.) Size 11.8 32.0 32.0 69.5 190.0 190.0 366.0 366.0 Aluminum Cat. Dimensions (in.) Size 11.8 32.0 32.0 69.5 Threaded Aluminum Aluminum 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Form Form Conduit Outlet Bodies Fittings Form Cat. C77-TB Dimensions (in.) Size 5.45 6.05 6.75 7.30 8.60 9.50 12.10 12.10 1.40 1.60 1.90 2.30 2.60 3.20 3.65 4.40 1.45 1.65 1.80 2.20 2.45 3.05 4.25 4.25 1.15 1.35 1.80 2.05 2.45 3.60 3.60 3.20 3.80 4.55 5.00 5.45 6.40 8.40 8.40 10.6 18.8 26.4 51.0 102.0 132.0 Form Form Form Cat. C58-TB Dimensions (in.) Size 13.0 23.5 45.0 88.0 110.0 110.0 Threaded Aluminum Cat. AC10 Dimensions (in.) Size 11.8 32.0 32.0 69.5 190.0 190.0 366.0 366.0 Aluminum Cat. Dimensions (in.) Size 11.8 32.0 32.0 69.5 Threaded Aluminum Aluminum 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Form Form Conduit Outlet Bodies Form Cat. LL17 LL27 LL37 LL47 LL57 LL67 LL77 LL87 LL97 LL107 Dimensions (in.) Size 4.60 5.25 6.00 6.45 7.90 8.30 10.55 10.55 12.85 12.85 1.40 1.60 1.90 2.30 2.60 3.20 3.65 4.40 4.90 5.40 1.45 1.65 2.60 3.05 3.80 4.25 5.80 5.80 7.03 7.03 1.15 1.35 1.80 2.05 2.45 3.60 3.60 4.55 4.55 3.20 3.80 4.55 5.00 5.45 6.40 8.40 8.40 10.25 10.25 10.6 18.6 26.4 51.0 102.0 132.0 210.0 243.0 Form Form Form Cat. LL18 LL28 LL38 LL48 LL58 LL68 LL78 LL888 Dimensions (in.) Size 13.0 23.5 45.0 88.0 110.0 110.0 Threaded Aluminum Cat. ALL1 ALL2 ALL3 ALL4 ALL5 ALL6 ALL7 ALL8 ALL9 ALL10 Dimensions (in.) Size 11.8 32.0 32.0 69.5 190.0 190.0 366.0 366.0 Style Only 12.5 36.5 36.5 73.8 Aluminum Cat. BLL1 BLL2 BLL3 BLL4 BLL5 BLL6 Dimensions (in.) Size 11.8 32.0 32.0 69.5 Style Only 12.5 36.5 36.5 73.8 Threaded Aluminum Aluminum 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Form Form Conduit Outlet Bodies Fittings Form Cat. LR17 LR27 LR37 LR47 LR57 LR67 LR77 LR87 LR97 LR107 Dimensions (in.) Size 4.60 5.25 6.00 6.45 7.90 8.30 10.55 10.55 12.85 12.85 1.40 1.60 1.90 2.30 2.60 3.20 3.65 4.40 4.90 5.40 1.45 1.65 2.60 3.05 3.80 4.25 5.80 5.80 7.03 7.03 1.15 1.35 1.80 2.05 2.45 3.60 3.60 4.55 4.55 3.20 3.80 4.55 5.00 5.45 6.40 8.40 8.40 10.25 10.25 10.6 18.8 26.4 51.0 102.0 132.0 210.0 243.0 Form Form Form Cat. LR18 LR28 LR38 LR48 LR58 LR68 LR78 LR888 Dimensions (in.) Size 13.0 23.6 45.0 88.0 110.0 110.0 Threaded Aluminum Cat. ALR1 ALR2 ALR3 ALR4 ALR5 ALR6 ALR7 ALR8 ALR9 ALR10 Dimensions (in.) Size 11.8 32.0 32.0 69.5 190.0 190.0 366.0 366.0 Style Only 12.5 36.5 36.5 73.8 Aluminum Cat. BLR1 BLR2 BLR3 BLR4 BLR5 BLR6 Dimensions (in.) Size 11.8 32.0 32.0 69.5 Style Only 12.5 36.5 36.5 73.8 Threaded Aluminum Aluminum 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Form Form Conduit Outlet Bodies Form Cat. Dimensions (in.) Size 5.60 6.20 7.35 7.30 8.60 9.50 1.80 2.00 2.30 2.30 2.60 3.20 3.05 3.30 3.80 3.85 5.05 5.45 1.15 1.35 1.80 2.05 2.45 3.20 3.80 4.55 5.00 5.45 6.40 16.9 19.3 27.5 52.8 Form Form Form Cat. Dimensions (in.) Size 15.0 24.0 46.5 88.0 Form Cat. L17-TB L27-TB L37-TB L47-TB L57-TB L67-TB Dimensions (in.) Size 4.60 5.25 6.00 6.45 7.90 8.30 1.40 1.60 1.90 2.30 2.60 3.20 1.45 1.65 2.60 3.05 3.80 4.25 1.15 1.35 1.80 2.05 2.45 3.20 3.80 4.55 5.00 5.45 6.40 Form Threaded Aluminum Cat. ALRL1 ALRL2 ALRL3 ALRL4 ALRL5 ALRL6 Dimensions (in.) Size 11.8 32.0 32.0 69.5 Style Only 12.5 36.5 36.5 73.8 Aluminum Cat. BLRL1 BLRL2 BLRL3 BLRL4 BLRL5 BLRL6 Threaded Aluminum Aluminum Dimensions (in.) Size 11.8 32.0 32.0 69.5 Style Only 12.5 36.5 36.5 73.8 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Form Form Conduit Outlet Bodies Form Cat. Dimensions (in.) Size 4.60 5.25 6.00 1.40 1.60 1.90 1.45 1.65 1.80 1.15 1.35 3.20 3.80 4.55 16.9 Fittings Form Threaded Aluminum Cat. AE-1 AE-2 AE-3 Dimensions (in.) Size 11.8 Form Cat. Dimensions (in.) Size 15.0 24.0 46.5 88.0 Form TB18 TB28 TB38 TB484 TB58 TB68 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Mogul Conduit Outlet Bodies Application Mogul bodies installed conduit systems pull outlets conductors that stiff, large size type insulation. Provide longer openings needed when pulling large conductors. Prevent sharp bends kinks large conductors (protects insulation during installation.) Provide ample openings splices taps. Provide access wiring maintenance, future system changes. Features Mogul bodies have: Long openings. Provision easy bends. Tapered tapped hubs with integral bushings. Stainless Steel cover screws. Covers gaskets included. Standard Materials Class Gray iron alloy. Standard Finishes Electrogalvanized aluminum acrylic paint. Certifications Compliances: Standard: 514B Fed. Spec.: W-C-586d Standard: C22.2 No.18 listed locations. Mogul Series Cat. Dimensions (in.) Size 9.56 9.56 13.75 13.75 18.38 18.38 23.75 23.75 1.88 2.31 2.56 3.31 3.63 4.38 4.88 5.38 2.25 2.25 4.25 4.25 5.25 5.25 7.84 7.84 11.45 11.45 15.61 15.82 20.50 20.50 20.0 25.0 60.0 78.0 180.0 225.0 410.0 460.0 BC3-TB BC4-TB BC5-TB BC6-TB BC7-TB BC8-TB BC9-TB BC10-TB SECTION Mogul Series Cat. BLB3-TB BLB4-TB BLB5-TB BLB6-TB BLB7-TB BLB8-TB BLB9-TB BLB10-TB Dimensions (in.) Size 8.66 8.66 12.58 12.58 16.94 16.94 22.16 22.16 2.80 2.70 2.56 4.16 5.10 5.81 6.50 7.00 2.25 2.25 4.25 4.25 5.25 5.25 6.92 6.70 10.36 10.13 13.89 13.59 18.32 18.06 20.0 25.0 62.0 78.0 170.0 210.0 410.0 460.0 SECTION 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Mogul Conduit Outlet Bodies Fittings Mogul Series Cat. BUB3-TB BUB4-TB BUB5-TB BUB6-TB BUB7-TB BUB8-TB BUB9-TB BUB10-TB Dimensions (in.) Size 9.49 9.55 16.68 13.68 18.30 18.30 23.74 23.74 2.75 3.21 6.67 4.28 5.03 5.67 6.72 7.22 2.25 2.25 4.25 4.25 5.25 5.25 7.01 6.71 10.47 10.20 13.97 13.50 18.07 17.73 20.0 25.0 62.0 78.0 170.0 210.0 385.0 430.0 SECTION Mogul Series Cat. BT3-TB BT4-TB BT5-TB BT6-TB BT7-TB BT8-TB BT9-TB BT10-TB Dimensions (in.) Size 9.56 9.56 13.75 13.75 18.38 18.38 23.75 23.75 1.88 2.31 2.56 3.31 3.63 4.38 4.88 5.38 3.16 3.16 4.06 4.06 5.59 5.72 6.88 6.88 7.84 7.84 11.45 11.45 15.61 15.82 20.50 20.50 20.0 25.0 62.0 78.0 180.0 225.0 410.0 460.0 SECTION Mogul Series Replacement Covers Cat. BG48T-B BG68-TB BG88-TB BG98-TB Dimensions (in.) Size 8.27 16.22 21.21 6.62 10.62 12.44 16.63 2.77 3.60 4.97 5.96 2.75 3.75 SECTION 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Aluminum Mogul Conduit Outlet Bodies Meets Article 370-28, Ratio Suitable Locations NEMA Application Raintight junction bringing electrical service into location. Spacious, accessible wiring chamber provides convenient location pull conductors make splices. Features/Benefits Copper-free* aluminum provides increased corrosion resistance. Precision cast machined surfaces permit safer wire pulling. Clean cover edges provide good gasket sealing. Precision threaded hubs allow trouble-free field installation rigid conduit. Deep slotted stainless steel cover screws faster installation. Clear cubic content markings speed approval inspectors. Dome style cover permits easy wire pulling. Meets Article 370-28, ratio. Standard Materials Mogul Pulling Elbows: cast aluminum alloy A360 with less than .004 copper content (copper-free). Stainless steel screws. Gaskets: Composition Standard Finish Aluminum lacquer finish Deep slotted stainless steel screws MALB Precision machined threads Copper-free aluminum Clean cover edges Strong beam construction Compliances Listed Certified Federal Spec. W-C-586 Article 370-28 Sample Specifications Mogul Pulling Elbows shall cast copper-free* aluminum alloy A360. conduit stops shall coined free rough edges. Mogul Pulling Elbows shall finished with aluminum lacquer. Mogul Pulling Elbows shall Catalog *Less than .004 copper content Smooth conduit stops Clear markings Large dome cover 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Aluminum Mogul Conduit Outlet Bodies Meets Article 370-28, Ratio Suitable Locations NEMA Fittings Complete with Cover, Gasket Screws Raintight Cat. MALB-3 MALB-4 MALB-5 MALB-6 MALB-3 through Size Unit Qty. Std. Pkg. lbs. Cat. MALB-7 MALB-8 MALB-9 MALB-10 MALB-7 through Size Unit Qty. Std. Pkg. lbs. 1100 1060 1900 1800 Cat. MGKV-4 through MGKV-4 MGKV-5 MGKV-6 MGKV-7 Size Unit Qty. Std. Pkg. lbs. MALB Size MALB 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings FS/FD Cast Device Boxes Covers Application Cast device boxes installed Accommodate wiring devices. pull boxes conductors threaded rigid conduit system, including internal ground screw. Provide openings make splices taps conductors. Provide access conductors maintenance future system changes. Connect conduit sections. Dead-End Features hubs have Threads with minimum five full threads integral bushing. Internal grounding screw standard boxes. Suitable locations when used with gasketed covers. Available shallow (FS) deep (FD) boxes. device enclosed exceeds depth. blank bodies where special arrangements conduit hubs entrances required. cover holes #6-32. Mounting lugs standard boxes. Size Range Hubs Materials Boxes: Class Gray iron alloy Covers: Sand cast alloy sheet steel Gaskets: Neoprene Finish Zinc-plated with aluminum acrylic paint Dead-End Listing Certifications 514A (wet locations when used with gasketed covers) CSA: C22.2 No.18 Shallow Single Gang Cast Device Boxes Cat. Dead-End FS019-TB FS1-TB FS2-TB FS3-TB Thru-Feed FSC1-TB FSC2-TB FSC3-TB Fig. Size Blank Dimensions (Inches) Throat Dia. Min. 0.570 0.755 0.935 0.570 0.755 0.935 Max. 0.610 0.810 1.035 0.610 0.810 1.035 Deep Single Gang Cast Device Boxes Thru-Feed Cat. Dead-End FD019-TB FD1-TB FD2-TB FD3-TB Thru-Feed FDC1-TB FDC2-TB FDC3-TB Fig. Size Blank Dimensions (Inches) Throat Dia. Min. 0.570 0.755 0.935 0.570 0.755 0.935 Max. 0.610 0.810 1.035 0.610 0.810 1.035 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com FS/FD Cast Device Boxes Covers Shallow Double Gang Cast Device Boxes Cat. Dead-End FS062-TB FS12-TB FS22-TB FS32-TB Thru-Feed FSC12-TB FSC222-TB FSC32-TB Fig. Size Blank Dimensions (Inches) Throat Dia. Min. 0.570 0.755 0.935 0.570 0.755 0.935 Max. 0.610 0.810 1.035 0.610 0.810 1.035 Fittings Dead-End Deep Double Gang Cast Device Boxes Cat. Dead-End FD062-TB FD12-TB FD22-TB FD32-TB Thru-Feed FDC12-TB FDC222-TB FDC32-TB Fig. Size Blank Dimensions (Inches) Throat Dia. Min. 0.570 0.755 0.935 0.570 0.755 0.935 Max. 0.610 0.810 1.035 0.610 0.810 1.035 Dead-End Double Gang Cast Device Boxes, Double Cat. FSS222-TB Fig. Size Dimensions (Inches) Throat Dia. Min. 0.755 0.755 Max. 0.810 0.810 FDS222-TB Dead-End Thru-Feed 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings FS/FD Cast Device Boxes Covers 1.405 dia. hole Single Gang Covers Cat. DSS100-TB DS21-TB DS23-TB DS32-TB DS100G-TB Description Blank, Sheet Steel Round Receptacle, Sheet Steel Duplex Receptacle, Sheet Steel Single Switch, Sheet Steel Blank, Cast Aluminum DSS100-TB DS21-TB Double Gang Covers Cat. S1002-TB S32232-TB S32212-TB S232-TB S322-TB S1002GSA-TB Description Blank, Sheet Steel Receptacle/Switch, Sheet Steel Single Receptacle/Switch, Sheet Steel Dual Receptacle, Sheet Steel Switch, Sheet steel Blank, Cast Aluminum with Gasket DS23-TB DS32-TB 1.405 dia. hole S1002-TB DS100G-TB S32232-TB S32212-TB S232-TB S322 S1002GSA-TB 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com FS/FD Aluminum Device Boxes Covers Fittings Application Industrial grade device boxes raintight covers protect wiring devices, switches, electronic components, terminal blocks Dry, Damp Locations. Spacious, accessible wiring chamber provides convenient location maintain change system, pull conductors make splices. Junction branch conduits. Aluminum boxes used with steel rigid conduit. 2AFSC CWP-G Features/Benefits Copper-free* aluminum, stainless steel cover springs hinge pins provide increased corrosion resistance. cast construction, boxes with securely fastened mounting plates industrial designed covers combine produce rugged protective enclosure devices industrial applications. Clean cover edges provide good gasket sealing. Precision threaded hubs allow trouble-free field installation rigid conduit. Clear cubic content markings speed approval inspectors. Boxes external design provides increased wiring room. Standard Materials cast aluminum alloy A360 with less than .004 copper content (copper-free). Cover hinge pins springs: Stainless steel. Standard Finish Aluminum lacquer finish. Compliances: Listed Boxes Certified with factory installed ground screw Covers Certified Federal Spec. W-C-586 Sample Specifications Industrial grade device boxes covers shall cast copper-free* aluminum alloy A360. conduit stops shall coined free rough edges. Raintight covers shall have stainless steel springs hinge pins suitable locations with cover closed (CFSB, CFST CFSTF suitable locations). Industrial grade device boxes covers shall finished with aluminum lacquer. Industrial grade device boxes covers shall Catalog **Less than .004 copper content **Consult factory lead time minimum quantity. Stainless steel springs Smooth conduit stops High quality gaskets Precision machined threads Copper-free* aluminum Clear marking 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings FS/FD Aluminum Device Boxes Covers Single Gang Boxes *Raintight Cat. Size Unit Qty. Std. Pkg. Suitable Locations NEMA lbs. AFSC Standard, Hole Box, Dead AFS-1 AFS-2 AFS-3 Standard, Hole Box, Through Feed AFSC-1 AFSC-2 AFSC-3 Standard, Hole Box, Dead AFSS-1 AFSS-2 Standard, Hole Box, Through Feed AFSCC-1 AFSCC-2 Deep, Hole Box, Dead ADFS-1 ADFS-2 ADFS-3 Deep, Hole Box, Through Feed ADFSC-1 ADFSC-2 ADFSC-3 *Raintight when used with appropriate covers. AFSS AFSCC Gang Boxes *Raintight Cat. Size Unit Qty. Std. Pkg. lbs. Standard, Hole Box, Dead 2AFS-1 2AFS-2 2AFS-3 Standard, Hole Box, Through Feed AFSC-1 2AFSC-2 Deep, Hole Box, Dead 2ADFS-1 2ADFS-2 2ADFS-3 *Raintight when used with appropriate covers. 2AFS 2AFSC ADFS ADFSC Multi-Gang Boxes *Raintight Cat. FSMG-TB Size threadless Conduit Std. Pkg. lbs. *Raintight when used with appropriate covers. 2ADFS FSMG-TB 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com FS/FD Aluminum Device Boxes Covers Suitable Locations with Cover Closed NEMA Fittings Single Gang Covers Complete with Gasket Screws *Raintight Cat. CWPDR CWPDR-FS Description Unit Qty. Std. Pkg. lbs. Duplex Receptacles, Horizontal CWPDR Duplex receptacle cover with spring doors, Device Mount CWPDR-FS Mount Duplex Receptacles, Vertical CFSDR Mount GFCI Receptacles Horizontal CFSH-G Mount GFCI Receptacles Vertical CWPV-G GFCI receptacle cover rectangular opening Device Mount CFSR-G Mount *Raintight when used with appropriate boxes. CWPV-DR CFSDR CWP-G CFSH-G CWPV-G CFSR-G Cat. Nominal Size Max. Device Face Dia. Unit Qty. Std. Pkg. CFSR Series Single Receptacles Vertical (Box Mount Only) CFSR-L 1.600" CFSR-S 1.395" CFSR-X 1.865" CFSR-XL 2.145" CFSR-Y 1.750 *Raintight when used with appropriate boxes. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings FS/FD Aluminum Device Boxes Covers Single Gang Covers Complete with Gasket Screws *Raintight Cat. Switch Cover CFST Switch Cover CFSTF Blank Cover CFSB Description Plunger Style, Switch Cover, Mount NEMA Front Lever, Switch Cover, Mount NEMA Blank Cover, Mount, NEMA Unit Qty. Std. Pkg. lbs. CFST CFSTF *Raintight when used with appropriate boxes. CFSB FS/FD Aluminum Device Boxes Covers Suitable Locations with Cover Closed NEMA Gang Covers Complete with Gasket Screws *Raintight Cat. Description Unit Qty. Std. Pkg. lbs. Duplex Receptacles 2CWPDR Duplex Receptacle Cover with Spring Doors, Device Mount Switch Duplex Receptacle 2CWTDR Switch Duplex Receptacle Cover, Box/Device Mount Single Receptacle 2CWPR-M Single Receptacle Cover, Hole Dia. 2b", Device Mount 2CFSR-M Single Receptacle Cover, Hole Dia. 2b", Mount Switches 2CFST Plunger Style Switch Cover, Mount 2CWPR-M 2CFSR-M Blank 2CFSB Blank Cover, Mount 2CWPDR 2CWTDR *Raintight when used with appropriate boxes. 2CFST 2CFSB 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com FS/FD Aluminum Device Boxes Covers Single Gang Covers Complete with Gasket Screws Cat. Description Unit Qty. Unit Qty. Std. Pkg. Std. Pkg. Std. Pkg. lbs. lbs. lbs. Duplex Receptacles Duplex receptacle Cover, Mount Switches Switch Cover, Mount Cat. Nominal Size Max. Device Face Dia. Fittings Single Receptacles (Box Mount Only) 1.600" 1.395" CRX-L 2.145" Cat. Gasket FS-GKV Description Composition Gasket Series FS-GKV Gang Covers Complete with Gasket Screws Cat. Description Unit Qty. Std. Pkg. lbs. Duplex Receptacles 2CDR Duplex Receptacle Cover, Device Mount Switches 2CTS Switch Cover, Device Mount Switch Duplex Receptacles 2CTDR Switch Duplex Receptacle Cover, Device Mount Gasket 2FS-GKV Composition Gasket 2CDR 2CTS 2CTDR 2FS-GKV 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings FS/FD Aluminum Device Boxes Covers Dimensions Cubic Inches (CI) Single Gang Boxes AFS, AFSC, AFSS, AFSCC AFSC AFSS AFSCC Cat. AFS-1 AFS-2 AFS-3 AFSC-1 AFSC-2 AFSC-3 AFSS-1 AFSS-2 AFSCC-1 AFSCC-2 Size 21.6 21.6 21.6 21.6 21.6 21.6 21.6 21.6 21.6 21.6 ADFS ADFSC ADFS, ADFSC Cat. ADFS-1 ADFS-2 ADFS-3 ADFSC-1 ADFSC-2 ADFSC-3 Size 31.3 31.3 31.3 31.3 31.3 31.3 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com FS/FD Aluminum Device Boxes Covers Dimensions Cubic Inches (CI) Gang Boxes Fittings 2AFS 2AFSC 2AFS, 2AFSC Cat. 2AFS-1 2AFS-2 2AFS-3 2AFSC-1 2AFSC-2 Size 36.0 36.0 36.0 36.0 36.0 2ADFS 2ADFSC 2ADFS, 2ADFSC Cat. 2ADFS-1 2ADFS-2 2ADFS-3 2ADFSC-2 2ADFSC-3 Size 54.0 54.0 54.0 54.0 54.0 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings FS/FD Aluminum Device Boxes Covers Dimensions Single Gang Covers CWPDR CWPDR-FS CWPV-DR CFSDR CWP-G CFSH-G CWPV-G CFSR-G CFSR Series Series CFST CFSTF CFSB 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com FS/FD Aluminum Device Boxes Covers Dimensions Gang Covers Fittings 2CWPDR 2CDR 2CTDR Dia. Dia. 2CWTDR 2CFSR-M 2CWPR-M 2CFST 2CTS 2CFSB 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Conduit Expansion Coupling XJG-TB Rigid Conduit Expansion Coupling Disassembly Required. Whenever install rigid expansion coupling long conduit run, normally need three hands, strong backs lots patience. relax. introduces new, no-hassle Rigid Conduit Expansion Coupling. Installation's just turns you're done. Rigid Conduit Expansion Coupling features innovations that provide conveniences installer, saving time money job. There's disassembly needed during installation, requiring fewer tools less opportunities lost pieces. XJG-TB Rigid Conduit Expansion Coupling also packs added punch: It's only fitting kind that features true internal bonding jumper. This eliminates need additional external bonding jumpers, there's fewer parts install. need fitting that give take without hassle, reach T&B's XJG-TB Rigid Conduit Expansion Coupling. It's latest breakthrough industry's leading line conduit fittings. Contact your local representative more information regarding XJG-TB Rigid Conduit Expansion Coupling complete line conduit fittings from name trust quality design manufacturing, Thomas Betts. Movement Gland Bonding Bushing Internal Bonding Jumper Internal Sliding Bushing (keyed) Movement Slide fitting onto conduit until stops internal sliding bushing. Tighten you're ready. parts reassemble! Innovative Design Makes Installations Easier. disassembly necessary install Fast, simple, requires fewer steps True Internal Bonding Jumper external grounding strap required Tamper-proof internal jumper protected from environment Exceeds code requirements long conduit runs permit linear movement With wrench, tighten gland compress Teflon packing, creating rain-tight seal around conduit. Thread next length conduit into other fitting tighten. You're done! 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Conduit Expansion Coupling Fittings Conduit Expansion Coupling XJG24-TB XJG28-TB XJG34-TB XJG38-TB XJG44-TB XJG48-TB XJG54-TB XJG58-TB XJG64-TB XJG68-TB XJG74-TB XJG78-TB XJG84-TB XJG88-TB XJG94-TB XJG98-TB XJG104-TB XJG108-TB XJG1208-TB Size Movement Diameter 2.43 2.43 2.67 2.67 3.36 3.36 3.36 3.36 3.86 3.86 4.96 4.96 4.96 4.96 6.37 6.37 6.37 6.37 7.99 Length 10.00 14.00 10.00 14.00 10.56 14.56 10.56 14.56 11.25 15.25 12.12 16.12 12.12 16.12 12.87 16.87 12.87 16.87 18.87 Height 2.75 2.75 2.99 2.99 3.68 3.68 3.68 3.68 4.18 4.18 5.25 5.25 5.25 5.25 6.75 6.75 6.75 6.75 8.56 Suggested Specifications Expansion Fittings Rigid Steel Intermediate Metal Conduit Where raceways require expansion fittings compensate thermal expansion contraction where expansion fittings telescoping sections metal raceway shall made electrically continous bonding jumpers other means: Fitting will constructed from malleable ductile iron with exterior interior zinc plating corrosion protection. fitting shall constructed that disassembly required during installation. Fitting shall raintight after installation. fitting shall have internal bonding jumper constructed tinned copper braid, sized meet fault current test requirements comply with bonding requirements article 250.98 External bonding jumper shall required comply with requirements. Accepted Manufacturers: Thomas Betts XJG-TB Series Please consult Technical Services special orders availability products shown this list. Standard Materials Finish Body Malleable Ductile Iron, available Coated Internal Bonding Jumper Tinned Copper Braid Exterior Interior Finish Zinc Plating, Aluminum Acrylic Paint Packing PTFE/Synthetic Fiber Material (Teflon®) Coated) Listed Certified (File E23018, Std. 514B) Suitable Locations (File LR2884, Std. C22.2 complete line makes specifying easy too. Thomas Betts offers wide variety quality fittings suitable outdoor hazardous locations. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Conduit Outlet Boxes Explosionproof, Dust-Ignitionproof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust-Ignitionproof Raintight Locations Application boxes used hazardous location conduit runs following: Allows mounting fixture outlets (when used with appropriate covers). Provides easy access wiring. Provides junction conduit wire pulling splices. Changes direction rigid conduit systems. Attaches more pieces conduit long runs. Guards against damage wires rigid conduit. Features hubs have minimum five full threads integral bushing. boxes furnished with internal grounding screw. Cover supplied with ring gasket. Size Range Access opening diameter Materials Bodies: Grade 60-45-10 Ductile Iron (Complies with ASstandard A536) Covers: cast aluminum Finish Boxes: Zinc-plated with aluminum acrylic paint Covers: Natural Listing Certifications UL514A (wet locations when used with gasketed covers) UL886 CSA: C22.2 Conduit Outlet Boxes Cat. GUA14-TB GUA16-TB GUA24-TB GUA26-TB GUA36-TB GUA47-TB GUA59-TB GUAB14-TB GUAB16-TB GUAB24-TB GUAB26-TB GUAB36-TB GUAB47-TB GUAB59-TB GUAB69-TB GUAB79-TB GUAC14-TB GUAC16-TB GUAC24-TB GUAC26-TB GUAC36-TB GUAC47-TB GUAC49-TB GUAC59-TB GUAC69-TB GUAD14-TB GUAD16-TB GUAD24-TB GUAD26-TB GUAD36-TB GUAD49-TB GUAD Size Dimensions (Inches) Throat Dia. Min. Max. .570 .570 .755 .755 .935 1.260 1.470 .570 .570 .755 .755 .935 1.260 1.470 1.880 2.320 .570 .570 .755 .755 .935 1.260 1.260 1.470 1.880 .570 .570 .755 .755 .935 1.260 .610 .610 .810 .810 1.035 1.360 1.590 .610 .610 .810 .810 1.035 1.360 1.590 2.047 2.380 .610 .610 .810 .810 1.035 1.360 1.360 1.590 2.047 .610 .610 .810 .810 1.035 1.360 Cubic Capacity 13.5 13.3 16.2 13.5 13.5 15.4 27.5 73.6 13.1 13.3 16.2 29.3 73.6 77.8 12.5 13.1 GUAB GUAC 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Conduit Outlet Boxes Explosionproof, Dust-Ignitionproof Cat. GUAL14-TB GUAL16-TB GUAL24-TB GUAL26-TB GUAL36-TB GUAL47-TB GUAL49-TB GUAL59-TB GUAL69-TB GUAM14-TB GUAM16-TB GUAM24-TB GUAM26-TB GUAM36-TB GUAM47-TB GUAM69-TB GUAN14-TB GUAN16-TB GUAN24-TB GUAN26-TB GUAN36-TB GUAN47-TB GUAN59-TB GUAN69-TB GUAT14-TB GUAT16-TB GUAT24-TB GUAT26-TB GUAT36-TB GUAT37-TB GUAT47-TB GUAT49-TB GUAT59-TB GUAT69-TB GUAT79-TB GUAW14-TB GUAW16-TB GUAW24-TB GUAW26-TB GUAX14-TB GUAX16-TB GUAX24-TB GUAX26-TB GUAX36-TB GUAX37-TB GUAX47-TB GUAX49-TB GUAX59-TB GUAX69-TB Size CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust-Ignitionproof Raintight Locations Fittings Conduit Outlet Boxes (continued) Dimensions (Inches) Throat Dia. Min. Max. .570 .570 .755 .755 .935 1.260 1.260 1.470 1.880 .570 .570 .755 .755 .935 1.260 1.880 .570 .570 .755 .755 .935 1.260 1.470 1.880 .570 .570 .755 .755 .935 .935 1.260 1.260 1.470 1.880 2.320 .570 .570 .755 .755 .570 .570 .755 .755 .935 .935 1.260 1.260 1.470 1.880 .610 .610 .810 .810 1.035 1.360 1.360 1.590 2.047 .610 .610 .810 .810 1.035 1.360 2.047 .610 .610 .810 .810 1.035 1.360 1.590 2.047 .610 .610 .810 .810 1.035 1.035 1.360 1.360 1.590 2.047 2.380 .610 .610 .810 .810 .610 .610 .810 .810 1.035 1.035 1.360 1.360 1.590 2.047 Cubic Capacity 13.4 13.3 16.2 74.5 77.8 12.5 12.5 29.2 13.5 16.9 31.5 13.5 13.3 15.9 23.3 29.3 77.2 77.7 77.8 13.5 13.3 23.3 77.8 GUAL GUAM GUAN GUAT GUAW Conduit Device Replacement Covers GUAX Cat. GUA04-TB GUA06-TB GUA07-TB GUA09-TB Opening Dia. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Application Junction branch conduits hazardous locations. Accessible wiring chamber provides convenient location maintain change system, pull conductors make splices. Unique mounting pads external design ideal installations devices instruments. Features/Benefits Copper-free* aluminum provides increased corrosion resistance. Precision cast machined surfaces permit safer wire pulling. Precision threaded hubs allow trouble-free field installation rigid conduit. cast construction industrial design combine produce rugged protective enclosure devices industrial applications. Clear cubic content markings speed approval inspectors. Standard Materials cast aluminum alloy A360 with less than .004 copper content (copper-free). Standard Finish Aluminum lacquer finish Compliances Listed Certified Suitable hazardous locations NEMA rated when ordered with O-ring installed Federal Spec W-C-586 External design GAFX GAJU Copper-free aluminum Unique mounting pads Sample Specifications Outlet boxes hazardous locations shall cast copper- free* aluminum alloy A360 suitable Class Groups Class Groups Class areas. conduit stops shall coined free rough edges. Outlet boxes hazardous locations shall finished with aluminum lacquer. Outlet boxes shall Catalog *Less than .004 copper content. Internal ground boss screw Smooth conduit stops Precision machined threads 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Fittings External Hubs with Installed Green Ground Screw Through Feed with Surface Cover Cat. GAC-1 GAC-2 GAC-3 GAC-4 GAC-5 GAC-6 Size Unit Qty. Std. Pkg. lbs. Dead with Surface Cover Cat. GAE-1 GAE-2 GAE-3 Size Unit Qty. Std. Pkg. lbs. Style with Surface Cover Cat. GAL-1 GAL-2 GAL-3 GAL-4 GAL-5 GAL-6 Size Unit Qty. Std. Pkg. lbs. Style with Surface Cover Cat. GALB-1 GALB-2 GALB-3 GALB-4 GALB-5 GALB-6 Size Unit Qty. Std. Pkg. lbs. GALB Style with Surface Cover Cat. GAT-1 GAT-2 GAT-3 GAT-4 GAT-5 GAT-6 Size Unit Qty. Std. Pkg. lbs. Made order items. Consult factory lead time minimum quantities. Suffix-OR: O-ring available NEMA rating. Consult factory lead time price. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations External Hubs with Installed Green Ground Screw Covers Style with Surface Cover Cat. GAX-1 GAX-2 GAX-3 GAX-4 GAX-5 GAX-6 Size Unit Qty. Std. Pkg. lbs. Style with Flange Surface Cover Cat. GAFX-1 GAFX-2 GAFX-3 Size Unit Qty. Std. Pkg. lbs. GAFX Surface Style Cover Cat. GAS-123 GAS-4 GAS-56 Cover Opening Fits Boxes 1d", Std. Pkg. lbs. Dome Style Cover (Class Group only) Cat. GAD-123 Cover Opening Fits Boxes Inside Height Std. Pkg. lbs. Made order items. Consult factory lead time minimum quantities. Suffix-OR: O-ring available NEMA rating. Consult factory lead time price. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Fittings External Hubs with Installed Green Ground Screw, Covers Plugs Style with Canopy Cover Cat. GAJU-1 GAJU-2 GAJU-3 GAJU-5 GAJU-6 Size Unit Qty. Std. Pkg. lbs. GAJU Canopy Style Cover Cat. GAJ-123 GAJ-4 GAJ-56 Cover Opening Fits Boxes 1d", Unit Qty. Std. Pkg. lbs. Made order items. Consult factory lead time minimum quantities. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof Dimensions Cubic Inches (CI) CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations EXUN EXUNL Size 20.3 20.3 20.0 Dimensions styles when cover used GAC, GAE, GAL, GALB, GAT, Cover Opening Size 4l"" 18.8 18.8 18.8 28.0 69.3 69.3 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof Dimensions Cubic Inches (CI) CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Fittings GAFX Cover Opening Size 20.0 20.0 19.0 Note: units supplied configuration with proper number explosion-proof close-up plugs make GAJU Cover Opening Size 23.8 23.8 23.8 33.3 82.8 82.8 Note: series boxes supplied with style covers. order these boxes with dome cover, consult factory. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Application Junction branch conduits hazardous locations. Accessible wiring chamber provides convenient location maintain change system, pull conductors make splices. Internal design ideal installation where space limited. Features/Benefits Copper-free* aluminum provides increased corrosion resistance. Precision cast machined surfaces permit safer wire pulling. Precision threaded hubs allow trouble-free field installation rigid conduit. cast construction industrial design combine produce rugged protective enclosure devices industrial applications. Clear cubic content markings speed approval inspectors. Standard Materials cast aluminum alloy A360 with less than .004 copper content (copper-free). Standard Finish Aluminum lacquer finish Compliances Listed Certified Suitable hazardous locations Federal Spec W-C-586 Sample Specifications Outlet boxes hazardous locations shall cast copper-free* aluminum alloy A360 suitable Class Groups Class Groups Class areas. conduit stops shall coined free rough edges. Outlet boxes hazardous locations shall finished with aluminum lacquer. Outlet boxes shall Catalog *Less than .004 copper content. EXUN EXUNL Copper-free aluminum Internal design Smooth conduit stops Precision machined threads Internal ground boss screw cast lugs 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Fittings Internal Hubs with Installed Green Ground Screw Hole Cat. EXUN-1 EXUN-2 EXUN-3 Size Description outlets with close-up plugs with close-up plugs Unit Qty. Std. Pkg. lbs. EXUN-1 Hole Cat. EXUN-11 EXUN-22 Size Description outlets with close-up plugs Unit Qty. Std. Pkg. lbs. EXUN-11 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Application Junction branch conduits hazardous locations. Accessible wiring chamber provides convenient location maintain change system, pull conductors make splices. GASS Features/Benefits Copper-free* aluminum alloy provides increased corrosion resistance. Extra wide opening provides more hand space easy access wiring chamber. Precision cast machined surfaces permit safer wire pulling. Large capacity chamber provides more wiring space. Precision threaded hubs allow trouble-free field installation rigid conduit. Sand cast construction industrial design combine produce rugged protective enclosure devices industrial applications. Clear cubic content markings speed approval inspectors. spacing allows EXFU EXMU unions. Standard Materials Sand Cast aluminum alloy A356. 2-T6 Cover Cast aluminum alloy A360 with less than .004 copper content (copper-free) Standard Finish Aluminum lacquer finish Compliances Listed Certified Sample Specifications Enclosure hazardous locations. shall cast copper-free* aluminum alloy A356.2-T6 Suitable hazardous locations: Suitable Class Groups Class Groups Class areas. Enclosures shall finished with aluminum lacquer. Outlet boxes shall Catalog *Less than .004 copper content. Clean cover edges Heavy wall construction Internal ground boss screw Precision machined threads Copper-free aluminum 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Aluminum Conduit Outlet Boxes Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Fittings Internal Hubs with Installed Green Ground Screw, Cover Plugs Cat. GASS-1 GASS-2 GASS-3 GASS Size Unit Qty. Std. Pkg. lbs. GASS Cover Opening Size 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Aluminum Conduit Outlet Bodies Explosion-Proof, Dust-Ignition-Proof Precision machined threads surfaces Heavy wall construction Deep slotted screws CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Application Junction branch conduits. Accessible wiring chamber provides convenient location pull conductors make splices. Features/Benefits Copper-free* aluminum provides increased corrosion resistance. Precision cast machined surfaces permit safer wire pulling. Precision threaded hubs allow trouble-free field installation rigid conduit. Deep slotted cover screws faster installation. Clear cubic content markings speed approval inspectors. Standard Materials cast aluminum alloy A360 with less than .004 copper content (copper-free). Standard Finish Aluminum lacquer finish Compliances Listed Certified Suitable hazardous locations Sample Specifications Conduit fittings hazardous locations shall cast copper free* aluminum alloy A360. Suitable hazardous locations: Class Groups Class Groups Class III. conduit stops shall coined free rough edges. Conduit fittings shall finished with aluminum lacquer. Conduit fittings shall Catalog *Less than .004 copper content. Smooth conduit stops Copper-free aluminum Style Conduit Body Aluminum Cat. EXLB-1 EXLB-2 EXLB-3 EXLB Size Std. Pkg. lbs. Style Conduit Body Aluminum Cat. EXT-1 EXT-2 EXT-3 Size Unit Qty. Std. Pkg. lbs. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Conduit Outlet Bodies Explosionproof, Dust-Ignitionproof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust-Ignitionproof Raintight Locations Fittings Application series installed conduit systems within hazardous areas Protect conductors threaded rigid conduit. pulling splice fittings. Interconnect lengths conduit. Change direction conduit. Provide access maintenance future system changes. Features conduit bodies have: Tapered threaded hubs ground continuity. Smooth integral bushings protect conductor insulation when pulling. Five different arrangements. Accurately machined body with blind tapped screw holes. Most compact design hazardous area outlet bodies. Sizes Standard Materials Bodies: Grade 60-45-10 Ductile Iron (Complies with ASstandard A536) Standard Finish Electrogalvanized aluminum acrylic paint. Size Ranges Certifications Compliances NEC/CEC:Class Division Groups Class Division Groups Class Division Groups Class Series Iron Conduit Outlet Bodies Cat. OEC1-TB OEC2-TB Size 4.06 4.35 4.06 4.35 4.06 4.35 4.06 4.35 4.06 4.35 1.62 1.88 1.62 1.88 1.62 1.88 1.62 1.88 1.62. 1.88 1.90 2.19 1.90 2.19 1.90 2.19 1.90 2.19 1.90 2.19 0.69 0.69 0.69 0.69 0.69 0.69 0.69 0.69 0.69 0.69 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.63 0.76 0.63 0.76 0.63 0.76 0.63 0.76 0.63 0.76 OET1-TB OET2-TB OELL1-TB OELL2-TB OELR1-TB OELR2-TB OELB1-TB OELB2-TB 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Conduit Outlet Elbows Explosionproof, Dust-Ignitionproof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust-Ignitionproof Raintight Locations Conduit Bodies Capped Elbows Application LBY/GYF elbows installed conduit systems within hazardous areas Make bends conduit systems where space limited. pull outlets. Provide access conductors maintenance future system changes. Features Maximum volume bends within compact overall size. Screw cover ease installation removal. Cover opening angle, permitting conductors pulled straight through either hub. Tapered threaded hubs integral bushing rigid threaded conduit. Class Division Groups Class Division Groups Class Class Division Groups Class Division Groups Class Capped Iron Elbow Female Female Cat. LBY15-TB LBY25-TB LBY35-TB LBY45-TB LBY55-TB LBY65-TB Size Throat Dim. 0.610 0.810 1.035 1.360 1.590 2.047 0.570 0.755 0.955 1.260 1.470 1.880 Elbows have: Maximum volume bends within compact overall size. Screw cover ease installation removal. Cover opening angle, permitting conductors pulled straight through either hub. Tapered threaded hubs integral bushing rigid threaded conduit. Capped Aluminum Elbow Female Female Cat. GYF-1 GYF-2 GYF-3 GYF-4 GYF-5 Size Unit Qty. Std. Pkg. lbs. Made order items. Consult factory lead time minimum quantities. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com PLG, Reducers, Plugs Adapters Explosionproof, Dust-Ignitionproof Application reducers used threaded heavy wall conduit systems. reduces conduit hubs smaller size. connects different sizes conduit together used replace coupling reducer installation. plugs used closing threaded conduit hubs. Features Hubs have threads with minimum five full threads integral bushing preventing damage wires. Materials Machined Reducers: Steel Cast Reducers: Gray Iron CI.I, Div. Groups Explosionproof Dust-Ignitionproof CI.II, Div. Groups CI.III, Div. Fittings Funnel Reducers: Iron Recessed Plugs: Gray Iron Recessed Plugs: Copper-free Aluminum Standard Finishes Cast zinc-plated with aluminum acrylic paint Machine zinc-plated with clear chromate finish Listing Certifications CSA: C22.2 No.30 NEC/CEC: CI.I, Div. Groups CI.II, Div. Groups CI.III hazardous non-hazardous locations Reducing Bushings Cat. RE21-TB RE31-TB RE32-TB RE41-TB RE42-TB RE43-TB RE51-TB RE52-TB RE53-TB RE54-TB RE61-TB RE62-TB RE63-TB RE64-TB RE65-TB RE73-TB RE74-TB RE75-TB RE76-TB RE83-TB RE84-TB RE85-TB RE86-TB RE87-TB RE96-TB RE97-TB RE98-TB RE106-TB RE107-TB RE108-TB Male (NPT) Female (NPT) Recessed Plugs Cat. Threads (NPT) With Flush Head Hazardous Non-Hazardous Locations PLG1-TB PLG2-TB PLG3-TB PLG4-TB PLG5-TB PLG6-TB PLG7-TB PLG8-TB PLG9-TB PLG10-TB Aluminum Recessed Plugs Cat. Size With Flush Head Hazardous Non-Hazardous Locations XPLG-1 XPLG-2 XPLG-3 XPLG-4* XPLG-5* XPLG-6* XPLG-7* XPLG-8* XPLG-9* XPLG-10* Series Reducers Cat. (NPT) (NPT) Funnel Shaped Reducers Hazardous Non-Hazardous Locations REC21-TB REC31-TB REC32-TB Made order items. Consult factory lead time minimum quantities. U.L. Listed U.L. Listed 34438 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Three-Piece Couplings Explosionproof, Dust-Ignitionproof CI.I, Div. Groups A,B,C,D CI.II, Div. Groups CI.III, Div. Explosionproof Dust-Ignitionproof Application unions installed threaded thickwall conduit systems: connect conduit conduit fitting, junction box, device enclosure. connect conduit conduit, provide means future modification conduit system. Standard Finishes Steel electrogalvanized with chromate treatment. Iron alloy, malleable iron electrogalvanized aluminum acrylic paint Certifications Compliances* NEC/CEC Class Division Groups A,B,C,D Class Division Groups E,F,G Class UNF, Conduit unions Cat. Nos. UNF/UNY followed 105, 205, 305; Class Division Groups A,B,C,D Class Division Groups E,F,G Class UNF,UNY Conduit unions Cat. Nos. UNF/UNY followed 105, 205, 305, 505; Class Division Groups B,C,D Class Division Groups E,F,G Class UNF,UNY 1b", Conduit unions Cat. Nos. UNF/UNY followed 505; Class Division Groups B,C,D Class Division Groups E,F,G Class UNF,UNY 1b", Conduit unions Cat. Nos. UNF/UNY, Series followed 605, 905, 1005; Class Division Groups Class Division Groups E,F,G Class UNF,UNY 2d", 3d", 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Three-Piece Couplings Explosionproof, Dust-Ignitionproof Cat. CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust-Ignitionproof Raintight Locations Fittings Male Unions Size Overall Length/Inches Overall Dia./Inches Hazardous Non-Hazardous Locations UNY105-TB UNY205-TB UNY305-TB UNY405-TB UNY505-TB UNY605-TB UNY705-TB UNY805-TB UNY905-TB UNY1005-TB LENGTH LENGTH MAX. DIA. MAX. DIA. Female Unions Cat. Size Overall Length/Inches Overall Dia./Inches Hazardous Non-Hazardous Locations UNF105-TB UNF205-TB UNF305-TB UNF405-TB UNF505-TB UNF605-TB UNF705-TB UNF805-TB UNF905-TB UNF1005-TB LENGTH LENGTH MAX. DIA. MAX. DIA. 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Fittings Aluminum Three-Piece Couplings Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Application Unions used connecting elements between enclosures, fittings boxes which permit future changes system both hazardous non-hazardous areas. Features/Benefits Copper-free* aluminum provides increased corrosion resistance. Precision cast machined surfaces permit safer wire pulling. Precision threaded hubs allow trouble-free field installation rigid conduit. Clear cubic content markings speed approval inspectors. Unique concentric ring design insures critical flame path control. Standard Materials cast aluminum alloy A360 with less than .004 copper content (copper-free). EXMU nipples galvanized steel. Standard Finish Aluminum lacquer finish Compliances Listed Certified Suitable hazardous locations Federal Spec W-C-586 Sample Specifications Conduit unions hazardous locations shall cast copperfree* aluminum alloy A360. Suitable hazardous locations: Class Groups Class Groups Class III. conduit stops shall coined free rough edges. Conduit unions shall finished with aluminum lacquer. Conduit unions shall Catalog *Less than .004 copper content. EXFU EXMU Precision machined threads Smooth conduit stops Unique concentric ring design Copper-free aluminum 2002 Thomas Betts Corporation. Specifications subject change without notice. www.tnb.com Aluminum Three-Piece Couplings Explosion-Proof, Dust-Ignition-Proof CI.I, Div. Groups CI.II, Div. Groups CI.III, Div. NEMA Explosionproof Dust Ignition-proof Raintight Locations Fittings Male Female Unions Female Female Cat. EXFU-1 EXFU-2 EXFU-3 EXFU-4 EXFU-5 EXFU-6 EXFU-7 EXFU-8 EXFU-9 EXFU-10 Size Unit Qty. Std. Pkg. lbs. EXFU Male Female Cat. EXMU-1 EXMU-2 EXMU-3 EXMU-4 EXMU-5 EXMU-6 EXMU-7 EXMU-8 EXMU-9 EXMU-10 Size Unit Qty. Std. Pkg. lbs. EXMU Made order items. Consult factory lead time minimum quantities. 2002 Thomas Betts Corporation. Specifications subject change without notice. Other recent searchesS29GL128P - S29GL128P S29GL128P Datasheet NTE2543 - NTE2543 NTE2543 Datasheet F0530602B - F0530602B F0530602B Datasheet APT25GP120BDF1 - APT25GP120BDF1 APT25GP120BDF1 Datasheet AD9832 - AD9832 AD9832 Datasheet 1N6104US - 1N6104US 1N6104US Datasheet
Privacy Policy | Disclaimer |