Conduit Fittings. Thinwall Conduit Fittings (EMT) E3-E14 Rigid/Interme


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Commercial Cast Fittings
Conduit Fittings. Thinwall Conduit Fittings (EMT) E3-E14 Rigid/Intermediate Grade Conduit Fittings E15-E27 Rigid/Aluminum Conduit Bodies, Gaskets Covers E28-E29 Aluminum Conduit Bodies, Gaskets Covers Flexible Cord Power Cable Connectors Liquidtight Flexible Nonmetallic Conduit Connectors Tubing E32-E33 Liquidtight Fittings. Liquidtight Flexible Metal Conduit Connectors E35-E37 Nonmetallic Sheathed Cable Flexible Cord Connectors Nonmetallic Sheathed Cable Fittings E39-E40 Armored Cable/Flexible Metallic Conduit Fittings E41-E46 Cable Straps, Cable Caps Service Entrance Fittings Grounding Clamps/Connectors Gutter Connectors/Cable Protector Cable Clip Beam Clamps Mounting Pipe Conduit Conduit Pipe Hangers Beam Clamps/Threaded Rod/ Coupling.
Conduit Fittings
Steel City® Conduit Fittings provide long-lasting service commercial, industrial residential construction. fittings manufactured within strict tolerances maintain consistent performance. Installers assured that every fitting with Steel City name will work every time. when select Steel City® Conduit Fittings, that means fewer headaches call-backs. Steel City® products symbolize highest quality standards manufacturing innovative design, with most complete offerings available. Contact distributor nearest select right Steel City® product your requirements.
Steel City
Advantages Steel City Commercial Conduit Fittings
Compression Fittings
Dependable Pipe Stop Strong thick protrusion that does exceed thickness EMT. Keeps forcefully inserted conduit from breaking through opposite side coupling while interfering with pulling conductors. Heavy Duty Thick Steel Body/Glands with Continuous Threading True hexagonal shape. non-circular design actual flats gripping power using hand tool force. Extra Thick Electroplated Zinc Finish Assures corrosion resistance while clear chromate coating gives fittings their quality shine luster.
Couplings Connectors
Superior Quality Design Strict tolerances throughout fitting assures straight conduit with sagging over extreme lengths. Chamfered entry provides lead-in conduit insertion. Dependable Pipe Stop 360° grove traveling circumference assures that conduit forcefully inserted won't break through opposite side fitting. Also, does exceed thickness prevents interference with pulling conductors. Extra Large Head Tri-Drive Set-Screw Accommodates Phillips, Slotted Square drives. Enhanced Locknut Construction Heavy-duty turned sharp teeth, double-threaded.
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Here's Steel City Part Number System Works
Easy identify alphabetical prefixes: Bushings, Grounding Bushings, Insulated Blanks Bushings Clamp Back Piece Coupling Ground Clamp (armored ground wire) Ground Clamp Heavywall Adapter Heavywall Connector Heavywall Coupling Heavywall Offset Heavywall Strap Locknut, Grounding Locknut Liquidtight Nonmetallic Sheathed Cable Connector Nonmetallic Sheathed Cable Strap Service Entrance Fitting Service Ells Sealing Rings Locknut, Sealing Thinwall Connectors Thinwall Couplings Thinwall Offset Thinwall Strap Thinwall Flexible Metallic Conduit Fitting Utility Connector Washer Armored Cable Flexible Metallic Conduit Connector Armored Cable Flexible Metallic Conduit Coupling Digit Material Steel Cast Combination Steel Cast Malleable Plastic Aluminum Steel Insulated Cast Insulated Malleable Insulated Digit Method Compression Screw Other 3rd/4th Digit Size examples three digit identification system thinwall fittings are: TK-111 steel, compression type coupling TC-714 steel insulated compression type connector TC-822 cast, insulated, set-screw type connector
Steel City
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Screw Connectors, Steel Non-Insulated
Cat# Conduit Size Inner Pack
Design
Outer Pack
Steel City
Concrete Tight Zinc Plated
TC121A TC122A TC123A TC124A TC125A TC126A TC127A TC128A TC129A TC1210A
Screw Connectors, Steel Insulated
Cat# Conduit Size Inner Pack Outer Pack
TC721A TC722A TC723A TC724A TC725A TC726A TC727A TC728A TC729A TC7210A U.L. File E-16592
Design
Screw Couplings Steel
Cat# Conduit Size Inner Pack Outer Pack
TK121A TK122A TK123A TK124A TK125A TK126A TK127A TK128A TK129A TK1210A Concrete Tight, when taped Zinc Plated U.L. File E-16592
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Compression Connectors, Steel Non-Insulated
Cat# Conduit Size Inner Pack
Design
Outer Pack
TC111A TC112A TC113A TC114A TC115A TC116A TC117A TC118A TC119A TC1110A 1/2" Concrete Tight Zinc Plated
Steel City
Compression Connectors, Steel Insulated
Cat# Conduit Size Inner Pack Outer Pack
TC711A TC712A TC713A TC714A TC715A TC716A TC717A TC718A TC719A TC7110A U.L. File E-16592
Design
Compression Couplings Steel
Cat# Conduit Size Inner Pack Outer Pack
TK111A TK112A TK113A TK114A TK115A TK116A TK117A TK118A TK119A TK1110A 1/2" Concrete Tight Zinc Plated U.L. File E-16592
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Conduit Connector
Cat. Description Std. Ctn.
TC-101-SC TC-102-SC TC-701-SC TC-702-SC
Uninsulated Uninsulated Insulated Insulated
Simple, one-piece installation with locknuts. Available insulated noninsulated throat. Screw designed exceptional pullout resistance. Captive screw ensures that screw intact installation resists backing after installation. Corrosion-resistant, zinc-chromatic plating. Concrete tight. Positive grounding. Vibration resistant screw design. listed certified.
U.L. Listing E16592, Listing LR-12798 Installation using either slotted Phillips screwdriver head, 35-in-lb torque onto EMT. NOTE: Excessive torque could damage housing.
Steel City
Additional Commercial Construction Products from Thomas Betts
Steel City Steel Boxes, Covers, Accessories
Notched Ears Switch Boxes provide clearance screws that used attach wall plates GFCI rocker-type light switches. Universal Metal Stud Bracket mounts without screws, open closed side stud works depth non-loadbearing metal stud. Eccentric Knockouts Square Boxes provide better contact with conduit fitting locknut box, improves grounding path, stronger than knockout. Improved Knockout Position Square Boxes requires less labor install conduit box. Raised Ground Screw Utility Boxes make quicker surface mounting eliminating need remove portion screw that threads through back box, allows improved repositioning grounding conductor. Preinstalled Screws Packaged raised position eliminates extra step having back screw during cover installation.
Steel City Underfloor Duct, Floor Boxes, Poke-Throughs
Steel City conventional underfloor duct offers multi-compartmental duct junction boxes with builtin tile trim. Header duct access hatch designs cellular underfloor duct system provide convenient wire cable access, eliminating junction boxes. Accommodate power, voice, data with Steel City flush floor boxes, available cast-iron, steel, nonmetallic constructions. Access floor modules blend with decor accommodate virtually raised floor surface. Steel City poke-through devices allow interchange flush, low-profile, standard service heads without removing lower core unit.
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Compression Connectors Cast Zinc, Noninsulated
Cat.
Conduit Size
Std. Ctn.
1/2" Concrete Tight
TC-211-SC TC-212-SC TC-213-SC TC-214-SC TC-215-SC TC-216-SC TC-217-SC TC-218-SC TC-219-SC TC-2110-SC U.L. File E-16592 d"-4" File LR-12798 d"-2
Steel City
Compression Connectors Cast Zinc, Insulated
Cat.
Conduit Size
Std. Ctn.
TC-811-SC TC-812-SC TC-813-SC TC-814-SC TC-815-SC TC-816-SC TC-817-SC TC-818-SC TC-819-SC TC-8110-SC U.L. File E-16592 d"-4" File LR-12798 d"-2
1/2" Concrete Tight
Compression Couplings Cast Zinc
Cat.
Conduit Size
Std. Ctn.
1/2" Concrete Tight
TK-211-SC TK-212-SC TK-213-SC TK-214-SC TK-215-SC TK-216-SC TK-217-SC TK-218-SC TK-219-SC TK-2110-SC
3TM"
U.L. File E-16592 d"-4" File LR-12798 d"-1b", 2d"-4"
Offset Compression Connectors Cast Zinc
Cat.
Conduit Size
Std. Ctn.
TO-211SC offset TO-212 offset U.L. File E-16592
2.98"
1.16"
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Screw Connectors Cast Zinc, Noninsulated
Cat.
Conduit Size
TC-221 Series TC-821 Series
Std. Ctn.
Concrete Tight, when taped
Steel City
TC-221-SC TC-222-SC TC-223-SC TC-224-SC TC-225-SC TC-226-SC TC-227-SC TC-228-SC TC-229-SC TC-2210-SC
Noninsulated U.L. File E-16592 d"-2" U.L. File E-1275 2d"-4" File LR-12798 d"-1", 2d"-4"
Screw Connectors Cast Zinc, Insulated
Cat.
Conduit Size
TC-221 Series TC-821 Series
Std. Ctn.
Concrete Tight, when taped
TC-821-SC TC-822-SC TC-823-SC TC-824-SC TC-825-SC TC-826-SC TC-827-SC TC-828-SC TC-829-SC TC-8210-SC
Insulated U.L. File E-16592 d"-2" U.L. File E-1275 2d"-4" File 12798 d"-2"
Screw Couplings Cast Zinc
Cat. Conduit Size Std. Ctn.
Concrete Tight, when taped
TK-221 TK-222 TK-223 TK-224 TK-225 TK-226 TK-227 TK-228 TK-229 TK-2210
U.L. File E-16592 d"-2" U.L. File E-1275 2d"-4" File LR-12798 d"-1b", 2d"-4"
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Connectors Angle Cast Zinc
Cat. Trade Size Std. Ctn. SCREW
SCREW TYPE COMPRESSION
TC-921
COMPRESSION
1.27 1.37 1.86
1.15 1.15
TC-911-SC TC-912-SC
Steel City
Capped Corner Couplings Die-Cast Zinc
Cat. Conduit Size Std. Ctn.
TL-291 TL-292 U.L. File E-16592 File LR-12798 Concrete Tight, when taped
1.81" 2.00"
1.00" 1.25"
Screw Connectors Die-Cast Zinc, Offset
Cat. Offset Conduit Size Std. Ctn.
TO-221 TO-222 TO-223 Concrete Tight, when taped
2.00" 2.98" 3.15"
.90" 1.16" 1.42"
U.L. File E-16592 File LR-18130M57
Screw Type Die-Cast Zinc
Cat. Conduit Size Std. Ctn.
TL-211 TL-212 U.L. File E-1275
1.31" 1.47"
.93" 1.22"
Screw Type Die-Cast Zinc
Cat. Conduit Size Std. Ctn.
TL-201 TL-202-SC TL-203 TL-204 U.L. File E-1275
1.31" 1.60" 1.94" 2.26"
1.10" 1.24" 1.59" 1.97"
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Combination Screw Couplings Die-Cast Zinc Flexible Metal Conduit
Cat.
Conduit Size
Std. Ctn.
Steel City
TX-220 TX-221 TX-222 TX-223 Concrete Tight, when taped U.L. File E-1275
flex flex flex flex
Combination Screw Couplings Thinwall Heavywall Die-Cast Zinc
Cat. Conduit Size Std. Ctn.
Concrete Tight, when taped
HT-221 HT-222 HT-223 U.L. File E-1275
Rigid Rigid Rigid
1.67" 1.98" 2.15"
1.07" 1.29" 1.58"
Corner
Corner
Combination Compression Couplings Thinwall Liquidtight Flexible Metal Conduit Steel
Cat. Conduit Size Std. Ctn.
Steel Rain Tight Zinc Plated
LTT-111 LTT-112 LTT-113
Liquidtight Liquidtight Liquidtight
1TM"
Corner
Corner
Combination Compression Couplings Heavywall Liquidtight Flexible Metal Conduit Steel
Cat. Conduit Size Std. Ctn.
LTH-111 Steel Rain Tight Zinc Plated
Rigid Liquidtight
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Combination Couplings Flex Compression Screw-In Type Cast Zinc
Cat. Trade Size Std. Ctn.
TX-201 TX-202
0.84 0.95
1.10 1.30
Steel City
Combination Couplings Flex Screw Type Cast Zinc
Cat.
Fig. d"-d" f"-f"
Fig.
Trade Size
A-Min
A-Max
Std. Ctn.
Fig. d"-c"
TX-210 TX-211 TX-212
0.15 0.60 0.78
0.61 1.00 1.20
1.16 1.71 1.93
Hole Snap-Straps Steel
Cat. Conduit Size Std. Ctn.
Steel Zinc Plated
TS-101 TS-102 TS-103 TS-104 TS-105 TS-106 HS-107 HS-108 HS-109 HS-110
0.57" 0.62" 0.75" 0.88" 0.99" 1.10" 1.28" 1.28" 1.28" 1.28"
1.79" 1.96" 2.25" 2.85" 3.16" 3.93" 5.00" 5.55" 6.37" 6.87"
1000
Pipe Spacers Thinwall Heavywall Cast
Cat.
Conduit Size
Std. Ctn.
CB-201 CB-202 CB-203 CB-204 CB-205 CB-206
1000
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Hole Straps Steel
Cat. Conduit Size Std. Ctn.
Steel City
Steel Zinc Plated
TS-901 TS-902 TS-903 TS-904 TS-905 TS-906
0.56" 0.62" 0.68" 0.75" 0.88" 1.00"
2.20" 2.67" 2.97" 3.67" 4.22" 4.91"
Nail Strap Steel
Cat.
Rigid/MC Size
Size
Flex Size
Std. Ctn.
N-101-SC N-102-SC N-103-SC
1000 1000 1000
Stamped Steel Zinc Plated
Connectors Piece Type Cast Zinc
Cat. Trade Size Std. Ctn.
TC-201-SC File E16592
0.68
1.05
1000
Connector
Space Caps Plastic
Cat.
Conduit Size
Std. Ctn.
Space
BT-501 BT-502 BT-503 BT-504 BT-505
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Aluminum Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE
BLR-1 BLR-2 BLR-3 BLR-4 BLR-5 BLR-6 BLR-7* BLR-8* BLR-9* BLR-10*
Steel City
Shipped with cover. Price includes cost cover body.
Aluminum Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE
BLL-1 BLL-2 BLL-3 BLL-4 BLL-5 BLL-6 BLL-7* BLL-8* BLL-9* BLL-10*
Shipped with cover. Price includes cost cover body.
Aluminum Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE
BC-1-RD BC-2-RD BC-3 BC-4 BC-5 BC-6 BC-7* BC-8* BC-9* BC-10*
Shipped with cover. Price includes cost cover body.
Aluminum Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE
BLB-1 BLB-2 BLB-3 BLB-4 BLB-5 BLB-6 BLB-7* BLB-8* BLB-9* BLB-10*
Shipped with cover. Price includes cost cover body.
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Thinwall Conduit Fittings (EMT)
Aluminum Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
Steel City
TYPE
BT-1 BT-2 BT-3 BT-4 BT-5 BT-6 BT-7* BT-8* BT-9* BT-10*
Shipped with cover. Price includes cost cover body.
Aluminum Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE BLRL
BLRL-1 BLRL-2 BLRL-3 BLRL-4 BLRL-5 BLRL-6
Shipped with cover. Price includes cost cover body.
Aluminum Covers with Stainless Steel Screws
Stamped aluminum (1/2" thru sizes) cast aluminum (21/2" thru sizes). Steel zinc plated screws.
Cat. Conduit Size Std. Ctn.
Fiber Gasket
Gaskets Composition
Cat. Conduit Size Std. Ctn.
CV-1 CV-2 CV-3 CV-4 CV-5 CV-6 CV-7 SCV-1 SCV-2 SCV-3 SCV-4 SCV-5
Neoprene Gasket
GKV-1 GKV-2 GKV-3 GKV-4 GKV-5 GKV-6 GKV-7
Gaskets Neoprene
Cat. Conduit Size Std. Ctn.
Fiber neoprene material
GKN-1 GKN-2 GKN-3 GKN-4 GKN-5 GKN-6 GKN-7
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Snap Blanks
Cat. Conduit Size Diameter Std. Ctn.
Steel Zinc Plated
BL-111 BL-112 BL-113 BL-114 BL-115 BL-116
1000 1000 1000
Steel City
Spacer Die-Cast Zinc space)
Cat.
Conduit Size
Std. Ctn.
BS-201
U.L. File E-1275
Threadless Compression Connectors
Cat. Conduit Size Std. Ctn.
1/2"-21/2" Steel 3"-4" Malleable Iron/Zinc plated
HC-401 HC-402 HC-403 HC-404 HC-405 HC-406 HC-407 HC-408 HC-409 HC-410 Suggested rigid conduit only. U.L. File E-1275 thru
Threadless Compression Couplings
Cat. Conduit Size Std. Ctn.
1/2"-21/2" Steel 3"-4" Malleable Iron/Zinc plated
HK-401 HK-402 HK-403 HK-404 HK-405 HK-406 HK-407 HK-408 HK-409 HK-410 Suggested rigid conduit only. U.L. File E-1275 thru
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Screw Connectors
Cat.
Conduit Size
Std. Ctn.
Steel City
Steel (concrete tight), when taped Zinc plated
HC-101 HC-102 HC-103 HC-104 HC-105 HC-106 HC-107 HC-108 HC-109 HC-110
Screw screws starting Trade Size Suggested rigid conduit only U.L. File E-1275 thru
Screw Connectors Insulated
Cat.
Conduit Size
Std. Ctn.
Steel (concrete tight), when taped Zinc plated
HC-701 HC-702 HC-703 HC-704 HC-705 HC-706 HC-707 HC-708
Screw screws starting Trade Size Suggested rigid conduit only U.L. File E-1275 thru
Screw Couplings
Cat.
Conduit Size
Std. Ctn.
Steel (concrete tight), when taped Zinc plated
HK-101 HK-102 HK-103 HK-104 HK-105 HK-106 HK-107 HK-108 HK-109 HK-110 screws starting U.L. File E-1275
3TM"
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Rigid Connectors Screw Type Cast Zinc
Cat. Conduit Size Std. Ctn.
HC-201 HC-202 HC-203
WITH INSULATED THROAT
1.34 1.44 1.54 1.34 1.44 1.54
0.39 0.45 0.49 0.39 0.45 0.49
HC-801 HC-802 HC-803
Rigid Connector
Steel City
Rigid Couplings Screw Type Cast Zinc
Cat. Trade Size Std. Ctn.
HK-201 HK-202 HK-203
1.77 2.06 2.29
1.09 1.34 1.61
Rigid Coupling
Short Radius Elbows Cast Zinc
Cat. Size (in.) Dimensions (in.) Shf. Ctn./ Ship Qty.
HL-201-SC HL-202-SC
1.17
1.04
50/500 25/250
USE: join rigid conduit right angles where lack room prevents using standard sweep elbow, terminate rigid conduit box. Listing E37148
Three Piece Couplings
Cat.
Conduit Size
Dimensions (in.) (Assembled)
Shf. Ctn./ Ship Qty.
1/2"-21/2" Steel 21/2"-6" Malleable Iron Zinc plated
EK-401 EK-402 EK-403 EK-404 EK-405 EK-406 EK-407 EK-408 EK-409 EK-410 EK-411 EK-412 U.L. File E-1275 thru
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Rigid Couplings Three Piece Type Cast Zinc
Cat. Trade Size Std. Ctn.
EK-201 EK-202
1.39 1.53
1.31 1.58
Steel City
Pull Corner Elbows Cast Zinc
Cat. Conduit Size Std. Ctn.
HL-601 HL-602 HL-603 HL-604 U.L. File E-1275
1.31" 1.60" 1.95" 2.26"
1.10" 1.24" 1.59" 1.97"
Rigid with Gasket Die-Cast Zinc
Cat. Conduit Size Std. Ctn.
HL-611 HL-612 U.L. File E-1275
1.31" 1.47"
1.09 1.29"
Zinc Cast with Insulated Throat*
Cat. Size Std. Ctn.
H050-SC Series
with sealing ring will fall out. Provides superior sealing exceptional watertight performance.
H050-SC H075-SC H100-SC H125-SC H150-SC H200-SC H250-SC H300-SC H350-SC H400-SC H500-SC H600-SC
*Available Nickel-Chrome plating. Consult customer service price delivery. *Available with coating. Consult customer service price delivery.
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Conduit Nipples Iron/Zinc Plated
Cat.
Conduit Size
Std. Ctn.
841-TB HA-401 HA-402 HA-403 HA-404 HA-405 HA-406 HA-407 HA-408 HA-409 HA-410 HA-411 HA-412 U.L. File E-1275 c"-3d"
Steel City
Conduit Nipples Insulated Iron/Zinc Plated
Cat.
Conduit Size
Std. Ctn.
HA-901 HA-902 HA-903 HA-904 HA-905 HA-906
Conduit Nipples Cast Zinc Noninsulated
Cat. Conduit Size Std. Ctn.
HA-201 HA-202 HA-203 HA-204 HA-205 HA-206 HA-207 HA-208 HA-209 HA-210 U.L. File E-1275
0.98" 1.18" 1.50" 1.75" 2.11" 2.61" 3.13" 3.90" 4.20" 4.79"
0.59" 0.70" 0.80" 1.06" 1.01" 1.20" 1.49" 1.65" 1.68" 1.73"
1000
Conduit Nipples Cast Zinc Insulated
Cat. Conduit Size Std. Ctn.
HA-801 HA-802 HA-803 HA-804 HA-805 HA-806 HA-807 HA-808 HA-809 HA-810
0.98" 1.18" 1.50" 1.75" 2.11" 2.61" 3.13" 3.90" 4.20" 4.79"
0.59" 0.70" 0.80" 1.06" 1.01" 1.20" 1.49" 1.65" 1.68" 1.73"
1000
U.L. File E-1275 only
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Conduit Nipples Cast Zinc Long
Cat.
Conduit Size
Std. Ctn.
HA-211 HA-212 HA-213
1000
U.L. File E-1275 only
Steel City
Offset Nipples Cast Zinc
Cat.
Conduit Size
Std. Ctn.
HO-221 HO-222 HO-223 HO-224 HO-225 HO-226 offset. U.L. File E-1275
2.60" 2.62" 2.68" 2.85" 2.88" 3.19"
1.00" 1.32" 1.51" 1.85" 2.08" 2.71"
Locknuts Steel/Zinc Plated
Cat.
Conduit Size
Dimensions (in.) (min.) (max.)
Std. Ctn.
LN-100-SC LN-101-SC LN-102 LN-103 LN-104 LN-105 LN-106 LN-107 LN-108 LN-109 LN-110 LN-111 LN-112 U.L. File E-1275
0.125" 0.140" 0.170" 0.170" 0.170" 0.187" 0.375" 0.375" 0.438" 0.438" 0.500" 0.561"
1.140" 1.420" 1.770" 2.281" 2.598" 3.175" 3.562" 4.250" 4.803" 5.402" 6.674" 7.934"
1000 1000 1000
Thin Construction Locknuts-Steel/Zinc Plated
Cat. Conduit Size Unit Qty. Std. Ctn.
SPLN-107 SPLN-108 SPLN-109 SPLN-110 *Not U.L. Listed
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Locknuts Cast Zinc
Cat.
Conduit Size
Dimensions (in.) (min.) (max.)
Std. Ctn.
LN-201 LN-202 LN-203 LN-204 LN-205 LN-206 LN-207 LN-208 LN-209 LN-210 File LR-12798 U.L. File E-1275
0.125" 0.140" 0.170" 0.170" 0.170" 0.187" 0.375" 0.375" 0.438" 0.438"
1.140" 1.420" 1.770" 2.281" 2.598" 3.175" 3.562" 4.250" 4.803" 5.402"
2000 1000 1000
Steel City
Locknuts-Nonmetallic
Cat.
Trade Size
Dia.
Thd.
Std. Ctn.
LN-501 LN-502 LN-503 Material: Nylon Color: Gray
d-14 f-14 1-11d
Sealing Locknuts Steel/Zinc Plated
Cat.
Conduit Size
Dimensions (in.) (min.) (max.)
Std. Ctn.
LS-101 LS-102 LS-103 LS-104 LS-105 LS-106 LS-107 LS-108 LS-109 LS-110 U.L. File E-1275
0.26" 0.27" 0.28" 0.32" 0.32" 0.32" 0.32" 0.32" 0.32" 0.32"
1.12" 1.37" 1.75" 2.06" 2.37" 2.87" 3.43" 4.12" 4.62" 5.18"
1000 1000
Grounding Locknuts Malleable Iron/Zinc Plated
Cat.
Conduit Size
Dimensions (in.) (min.) (max.)
Std. Ctn.
LG-401 LG-402 LG-403 LG-404 LG-405 LG-406 LG-407 LG-408 LG-409 LG-410 U.L. File E-1275
0.125" 0.140" 0.170" 0.170" 0.170" 0.187" 0.375" 0.375" 0.438" 0.438"
1.140" 1.420" 1.770" 2.281" 2.598" 3.175" 3.562" 4.250" 4.803" 5.402"
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Conduit Bushings Cast Zinc Insulated Metallic
Cat. Conduit Size Std. Ctn.
Steel City
105°C thermoplastic liners. Heavy reinforced ribs.
BU-801 BU-802 BU-803 BU-804 BU-805 BU-806 BU-807 BU-808 BU-809 BU-810
1.06 1.31 1.59 1.96 2.18 2.68 3.25 3.87 4.37 5.00
0.43 0.43 0.48 0.56 0.60 0.56 0.90 0.85 0.93 0.93
1000 1000
Conduit Bushings Cast Zinc Heavy Reinforced Ribs
Cat. Conduit Size Dimensions (in.) (min.) (max.) Std. Ctn.
BU-201 BU-202 BU-203 BU-204 BU-205 BU-206 BU-207 BU-208 BU-209 BU-210
1.05 1.32 1.58 1.94 2.20 2.69 3.23 3.84 4.35 5.02
0.37 0.37 0.47 0.50 0.52 0.52 0.85 0.85 0.85 0.85
1000 1000
Insulated Bushings Thermoplastic
Cat.
Conduit Size
Std. Ctn.
BU-501 BU-502 BU-503 BU-504 BU-505 BU-506 BU-507 BU-508 BU-509 BU-510 BU-511 BU-512 U.L. File E-1275 d"-4" only Rated 105°C
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Bushings Iron/Zinc Plated
Cat.
Conduit Size
Std. Ctn.
BU-401 BU-402 BU-403 BU-404 BU-405 BU-406 BU-407 BU-408 BU-409 BU-410 BU-411 U.L. File E-1275
1000 1000
Steel City
Insulated Bushings Iron/Zinc Plated
Cat.
Conduit Size
Std. Ctn.
BI-901 BI-902 BI-903 BI-904 BI-905 BI-906 BI-907 BI-908 BI-909 BI-910
1000 1000
Grounding Bushings Cast Zinc Insulated Metallic With Aluminum Type
Cat. Trade Size Grounding Wire size min. Std. Ctn.
105°C Thermoplastic liners. Heavy reinforced ribs.
BG-201 BG-202 BG-203 BG-204A BG-204 BG-205A BG-205 BG-206A BG-206 BG-207 BG-207A BG-208 BG-208A BG-209 BG-209A BG-210 BG-210A
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Insulated Grounding Bushings Malleable Iron/Zinc Plated
Cat. Conduit Size Grounding Wire Capacity Std. Ctn.
Steel City
BG-801 BG-802 BG-803 BG-804 BG-805 BG-806 BG-807 BG-808 BG-809 BG-810 U.L. File E-19851 d"-2" Iron 2b"-4" Cast Zinc
#14-#4 #12-#4 #14-1/0 #12-1/0 #6-250
Grounding Bushings Cast Zinc Insulated Metallic With Aluminum
Cat. Trade Size Grounding Wire size min. Std. Ctn.
copper aluminum bare ground wire. 105°C thermoplastic liners. Heavy reinforced ribs.
BG-801A BG-802A BG-803A BG-804A 805A BG-806A BG-807A BG-808A BG-809A BG-810A BG-810B U.L. File E-19851
Reducing Bushings
Cat.
Conduit Size
Std. Ctn.
RB-121 thru RB-165 Steel. RB-175 thru RB-187 Malleable Iron (concrete tight)/ Zinc Plated.
RB-121 RB-131 RB-132 RB-141 RB-142 RB-143 RB-151 RB-152 RB-153 RB-154 RB-161 RB-162 RB-163 RB-164 RB-165 RB-175 RB-176 RB-186 RB-187 U.L. File E-1275
f"-d" 1"-d" 1"-f" 1b"-d" 1b"-f" 1b"-1" 1d"-d" 1d"-f" 1d"-1" 1d"-1b" 2"-d" 2"-f" 2"-1" 2"-1b" 2"-1d" 2d"-1d" 2d"-2" 3"-2" 3"-2d"
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Reducers Enlargers Malleable Iron/Zinc Plated
Cat.
Conduit Size
Std. Ctn.
RB-421 RB-432 RB-443
f"-d" d"-f" 1"-f"
U.L. File E-1275
Steel City
Reducing Washers Steel/Zinc Plated
Cat. Conduit Size Diameter Std. Ctn.
WA-110 WA-121 WA-131 WA-132 WA-141 WA-142 WA-143 WA-151 WA-152 WA-153 WA-154 WA-161 WA-162 WA-163 WA-164 WA-165 WA-171 WA-172 WA-173 WA-174 WA-175 WA-176 WA-181 WA-182 WA-183 WA-184 WA-185 WA-186 WA-187
d"-c" f"-d" 1"-d" 1"-f" 1b"-d" 1b"-f" 1b"-1" 1d"-d" 1d"-f" 1d"-1" 1d"-1b" 2"-d" 2"-f" 2"-1" 2"-1b" 2"-1d" 2d"-d" 2d"-f" 2d"-1" 2d"-1b" 2d"-1d" 2d"-2" 3"-d" 3"-f" 3"-1" 3"-1b" 3"-1d" 3"-2" 3"-2d"
WA-121 thru WA-165 listed.
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Hole Straps Steel/Zinc Plated
Cat. Screw Size Conduit Size Std. Ctn.
Steel City
HS-100-SC HS-101 HS-102 HS-103 HS-104 HS-105 HS-106 HS-107 HS-108 HS-109 HS-110
1000
Pipe Straps Malleable Iron/Zinc Plated
Cat. Screw Size Conduit Size Std. Ctn.
HS-400 HS-401 HS-402 HS-403 HS-404-SC HS-405 HS-406 HS-407 HS-408 HS-409 HS-410 HS-411
10s"
Hole Strap Steel/Zinc Plated
Cat. Screw Size Conduit Size Std. Ctn.
HS-901 HS-902 HS-903 HS-904 HS-905 HS-906 HS-907 HS-908 HS-909 HS-910 Certified
1200
Nail Strap Stamped Steel/Zinc Plated
Cat.
Rigid/MC Size
Size
Flex Size
Std. Ctn.
N-101-SC N-102-SC N-103-SC
1000 1000 1000
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Flange Plates Malleable Iron/Zinc Plated
Cat.
Conduit Size
Dia.
Depth
Std. Ctn.
Bolt Hole
FP-401 FP-402 FP-403 FP-404 FP-405 FP-406
.625 .656 .765 .875 .937 .843
Steel City
Pipe Spacers Rigid/Intermediate Thinwall Cast Zinc
Cat. Conduit Size Std. Ctn.
CB-201 CB-202 CB-203 CB-204 CB-205 CB-206
1000
Rigid/Intermediate Space Caps Plastic
Cat. Conduit Size Std. Ctn.
BR-501 BR-502 BR-503 BR-504 BR-505
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Aluminum Conduit Bodies, Gaskets Covers
Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE
cast copper free aluminum construction. Provide access pulling, splicing, maintenance. rigid conduit/IMC applications. U.L. Listed. Fittings, covers gaskets interchangeable with those produced other leading manufacturers. Finish: Powder Coated Urethane.
Steel City
ALR-1 ALR-2 ALR-3 ALR-4 ALR-5 ALR-6 ALR-7* ALR-8* ALR-9* ALR-10*
Shipped with cover. Price includes cost cover body.
Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE
cast copper free aluminum construction. Provide access pulling, splicing, maintenance. rigid conduit/IMC applications. U.L. Listed. Fittings, covers gaskets interchangeable with those produced other leading manufacturers. Finish: Powder Coated Urethane.
ALL-1 ALL-2 ALL-3 ALL-4 ALL-5 ALL-6 ALL-7* ALL-8* ALL-9* ALL-10*
Shipped with cover. Price includes cost cover body.
Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE
AC-1 AC-2 AC-3 AC-4 AC-5 AC-6 AC-7* AC-8* AC-9* AC-10*
Shipped with cover. Price includes cost cover body.
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Rigid/Aluminum Conduit Bodies, Gaskets Covers
Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE
ALB-1 ALB-2 ALB-3 ALB-4 ALB-5 ALB-6 ALB-7* ALB-8* ALB-9* ALB-10*
Steel City
Shipped with cover. Price includes cost cover body.
Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE
AT-1 AT-2 AT-3 AT-4 AT-5 AT-6 AT-7* AT-8* AT-9* AT-10*
Shipped with cover. Price includes cost cover body.
Conduit Bodies, Covers Gaskets Style
Cat. Trade Size Std. Ctn.
TYPE ALRL
ALRL-1 ALRL-2 ALRL-3 ALRL-4 ALRL-5 ALRL-6
Shipped with cover. Price includes cost cover body.
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Aluminum Conduit Bodies, Gaskets Covers
Aluminum covers with Stainless Steel Screws
Cat. Conduit Size Std. Ctn.
Stamped aluminum (1/2" thru sizes) cast aluminum (21/2" thru sizes). Steel zinc plated screws.
Steel City
CV-1 CV-2 CV-3 CV-4 CV-5 CV-6 CV-7 SCV-1 SCV-2 SCV-3 SCV-4 SCV-5
Gaskets Composition
Cat.
Fiber Gasket
Conduit Size
Std. Ctn.
GKV-1 GKV-2 GKV-3 GKV-4 GKV-5 GKV-6 GKV-7
Gaskets Neoprene
Neoprene Gasket
Cat.
Conduit Size
Std. Ctn.
Fiber neoprene material
GKN-1 GKN-2 GKN-3 GKN-4 GKN-5 GKN-6 GKN-7
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Flexible Cord Power Cable Connectors
BLACK BEAUTY Nonmetallic Liquidtight Strain Relief Connectors
Installs cord hand. Achieves maximum pullout strength without installation tools. Each size takes range cord diameters. metallic construction provides corrosion resistance. Weathers stabilized nylon rated -34°C +105°C temperature.
Steel City
Straight
Cat. Trade Size Cord Range Throat Size Flat Max. Std. Ctn.
13938
52391
2671 2690 2672 2673* 2691* 2692* 2693 2694* 2674 2675 2696* 2697 2698* 2695 2676 2677 2678 2699 2700 2702 2703* 2704* 2705-TB 2706 2707* 2708 2709 2710*
.125-.275 .125-.275 .250-.400 .400-.560 .560-.690 .660-.780 .250-.400 .400-.560 .560-.690 .660-.780 .770-.895 .250-.400 .400-.560 .560-.690 .660-.780 .770-.895 .870-1.020 .890-1.090 1.080-1.280 .890-1.090 1.080-1.280 1.270-1.470 .890-1.150 1.140-1.400 1.390-1.650 1.190-1.530 1.520-1.860 1.850-2.190
0.33 0.33 0.55 0.55 0.54 0.54 0.55 0.55 0.79 0.79 0.76 0.54 0.54 0.98 0.98 0.98 0.98 0.98 0.98 1.25 1.25 1.25 1.47 1.47 1.47 1.89 1.89 1.89
1.00 1.08 1.08 1.32 1.32 1.22 1.22 1.34 1.34 1.64 1.50 1.50 1.60 1.60 1.60 1.60 2.25 2.25 2.25 2.25 2.25 2.65 2.65 2.65 3.13 3.13 3.13
1.27 1.27 1.57 1.57 1.27 1.27 1.57 1.57 1.89 1.27 1.27 1.89 1.89 1.89 1.89 2.58 2.58 2.58 2.58 2.58 2.95 2.95 2.95 3.50 3.50 3.50
*Remove sufficient outer covering cable permit conductors pass thru connector body. certified factory installation. Material: Weather Stabilized Nylon, Rated 34°C 105°C Temperature. Style AS-72555.
Degree Angle
Cat. Trade Size Cord Range Throat Size Flat Std. Ctn.
2680 2681 2682* 2683 2684 2688 2685 2686 2687*
.125-.275 .250-.400 .400-.560 .560-.690 .660-.780 .560-.690 .660-.780 .770-.895 .870-1.020
1.00 1.00 1.00
1.06 1.06 1.280 1.280 1.280 1.280
1.27 1.27 1.57 1.57 1.89 1.89 1.89 1.89
1.00 1.35 1.35 1.60 1.60 1.90 1.90 1.90 1.90
13938
52391
*Remove sufficient outer covering cable permit conductors pass thru connector body. certified factory installation.
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Liquidtight Flexible Nonmetallic Conduit Connectors Tubing
Connectors Liquidtight Flex Nonmetallic Conduit
Cat. Trade Size .015 (0.40) Inch (mm) ±.35 (0.90) Inch (mm) ±.015 (0.40) Min. Across Throat Corners Dia. Thread Inch (mm) Inch (mm) NPT. Inch (mm) Approx. Std. Ctn.
Steel City
LT-500 LT-501 LT-502 LT-503
.570 .570 .582 .726
1.595 (40.51) 1.636 (41.55) 1.757 (44.63) 1.923 (48.84)
1.354 1.448 1.740 2.068
.417 .550 .740 .940
d-14 d-14 f-14 1-11/12
1.880 (47.75) 1.986 (50.44) 2.212 (56.18) 2.508 (63.70)
Connectors Liquidtight Flex Nonmetallic Conduit
Cat. Trade Size .015 (0.40) Inch (mm) ±.35 (0.90) Inch (mm) ±.015 (0.40) Min. Across Throat Corners Dia. Thread Inch (mm) Inch (mm) NPT. Inch (mm) Approx. Std. Ctn.
LT-590 LT-591 LT-592 LT-593
(14.48) (14.48) (14.78) (18.44)
1.380 (35.05) 1.489 (37.82) 1.790 (45.47) 2.104 (53.44)
(34.39) (36.78) (44.20) (52.53)
(10.59) (13.97) (18.80) (23.88)
d-14 d-14 f-14 1-11/12
1.880 (47.75) 1.986 (50.44) 2.212 (56.18) 2.508 (63.70)
Standard Material/Finish Body/Gland-Nylon-Grey Ring-Nitrate (Black) Locknut-Nylon Temp. Rating-80°C Material Flammability Rating: UL94-V2 Listed/Certified U.L. Listed (File E23018) C.S.A. (File LR52391) Conforms Watertight requirements Type
Connectors Liquidtight Flex Nonmetallic Conduit
Cat. Trade Size .015 (0.40) Inch (mm) ±.35 (0.90) Inch (mm) ±.015 (0.40) Min. Across Throat Corners Dia. Thread Inch (mm) Inch (mm) NPT. Inch (mm) Approx. Std. Ctn.
LT-540 LT-541 LT-542 LT-543
(14.48) (14.48) (14.78) (18.44)
2.012 (51.10) 2.092 (53.14) 2.452 (62.28) 2.684 (68.17)
(34.39) (36.78) (44.20) (52.53)
(10.59) (13.97) (18.80) (23.88)
d-14 d-14 f-14 1-11/12
1.534 (38.95) 1.590 (40.39) 1.821 (46.25) 2.034 (51.66)
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Liquidtight Flexible Nonmetallic Conduit Connectors Tubing
Liquidtight Flexible Nonmetallic Conduit (Type Outdoor XTRAFLEX® Raceway System
Cat. Series Trade Size I.D. Min. Max. Min. O.D.IN. Max. Std. Ctn.
LTC038GY LTC050GY LTC075GY LTC100GY LTC125GY LTC150GY LTC200GY
.484 .622 .820 1.041 1.380 1.575 2.020
.504 .642 .840 1.066 1.410 1.600 2.045
.690 .820 1.030 1.290 1.630 1.865 2.340
.710 .840 1.050 1.315 1.660 1.900 2.375
Steel City
Color: Gray Length: LTC038GY thru LTC125GY LTC150GY LTC200GY U.L. Listed: File E95745 U.L. Temperature Rating: 80°C dry, 60°C wet, 70°C oil. res. sunlight resistant, outdoor, direct burial. Certified: File 80349-2 Temperature Rating: 75°C to-18°C with Thomas Betts LT38P, LT38M, LT500 series Liquidtight Flexible Metal Conduit Fittings. Material: Helix reinforcement surrounded with flexible PVC. Voltage Rating: 600V
Liquidtight Whip Assembly
Cat. Conduit Size Length Wire Gauge Std. Ctn.
LTWHIP 12-6-10 LTWHIP 12-4-10 LTWHIP 34-6-8 LTWHIP 34-4-8 LTWM 12-6-10 LTWM 12-4-10 LTWM 34-6-8 LTWM 34-4-8
Whip with metallic fittings straight,
Conduit Cutter Nonmetallic Flexible Conduit
Cat. Description
XF-CUT XF-BLAD
cutting flexible conduit Replacement blade XF-CUT
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Liquidtight Fittings
RANGE RANG
Versa GroundLIquidtight Fittings
Cat. Trade Size Std. Ctn.
5331GR 5332GR 5333GR 5334GR
14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4
Steel City
5231GR 5232GR 5233GR 5234GR 5231ALGR 5232ALGR 5233ALGR 5234ALGR
RANGE RANG
Versa GroundLIquidtight Fittings Type
Cat. Trade Size Std. Ctn.
5351GR
5352GR
5353GR 5354GR 5251GR 5252GR 5253GR 5254GR 5251ALGR 5252ALGR 5253ALGR 5254ALGR
14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4
RANGE RANG
Versa GroundLIquidtight Fittings
Cat. Trade Size Std. Ctn.
5341GR 5342GR 5343GR 5344GR
14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4
5241GR 5242GR 5243GR 5244GR
LUGRANGE RANG
Liquidtight Rigid External Ground Adapter
Cat. Trade Size Std. Ctn.
5271GR 5272GR 5273GR 5274GR
14-4 14-4 14-4 14-4
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Liquidtight Flexible Metal Conduit Connectors
Straight Connectors
Cat. Conduit Size Diameter Std. Ctn.
3/8"-1" Steel. 11/4"-2" Malleable Iron/Zinc Plated.
LT-100 LT-101 LT-102 LT-103 LT-104 LT-105 LT-106 File LR-12798 U.L. File E-1275 -c"-4"
Steel City
Straight Connectors
Cat. Conduit Size Diameter Std. Ctn.
3/8"-1" Steel. 11/4"-2" Malleable Iron/Zinc Plated (with insulated throat).
LT-700 LT-701 LT-702 LT-703 LT-704 LT-705 LT-706
Connectors Malleable Iron/Zinc Plated
Cat. Conduit Size Dimensions Std. Ctn.
LT-450 LT-451 LT-452 LT-453 File LR-12798 U.L. File E-1275
Connectors Malleable Iron/Zinc Plated (with insulated throat)
Cat. Conduit Size Dimensions Std. Ctn.
LT-950 LT-951 LT-952 LT-953
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Liguidtight Flexible Metal Conduit Connectors
Connectors Malleable Iron/Zinc Plated
Cat. Conduit Size Dimensions Std. Ctn.
LT-490 LT-491 LT-492 LT-493
Steel City
File LR-12798 U.L. File E-1275
Connectors Malleable Iron/Zinc Plated (with insulated throat)
Cat. Conduit Size Dimensions Std. Ctn.
LT-990 LT-991 LT-992 LT-993
Straight Connectors Die-Cast Zinc
Cat. Conduit Size Diameter Std. Ctn.
LT-200 LT-201 LT-202 LT-203 LT-205 LT-206 LT-207 LT-208 LT-209 LT-210 U.L. File E-1275
1.81" 1.88" 2.03" 2.28" 2.78" 3.22" 3.53" 3.91" 4.04" 4.16"
0.50" 0.61" 0.56" 0.63" 0.78" 0.78" 0.84" 0.88" 0.91" 0.94"
1.06" 1.19" 1.44" 1.75" 2.75" 3.53" 4.28" 4.72" 5.42" 5.91"
Straight Connectors Cast Zinc (with insulated throat)
Cat. Conduit Size Diameter Std. Ctn.
LT-800 LT-801 LT-802 LT-803 File LR-12798
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Liquidtight Flexible Metal Conduit Connectors
Connectors Die-Cast Zinc
Cat. Conduit Size Diameter Std. Ctn.
LT-290 LT-291 LT-292 LT-293 LT-294 LT-295 LT-296 U.L. File E-1275
1.88" 2.00" 2.19" 2.56" 3.00" 3.38" 4.06"
1.38" 1.41" 1.66" 1.88" 2.00" 2.56" 3.00"
0.50" 0.50" 0.56" 0.63" 0.69" 0.78" 0.78"
Steel City
Connectors Die-Cast Zinc (with insulated throat)
Cat. Conduit Size Diameter Std. Ctn.
LT-890 LT-891 LT-892 LT-893
1.88" 2.00" 2.19" 2.56"
1.38" 1.41" 1.66" 1.88"
0.50" 0.50" 0.56" 0.63"
Sealing Rings
Cat. Conduit Size Std. Ctn.
SR-101 SR-102 SR-103 SR-104 SR-105 SR-106 Material: Neoprene
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Nonmetallic Sheathed Cable Flexible Cord Connectors
Plastic Connector Cable Flexible Cord
Cat. Size Range K.O. Size Fig. Max. Thk. Enclosure Std. Ctn.
3300
Steel City
Snap captive locking wedge into connector's cavity.
with 10-2, 12-2 14-2 cables; 18-2 18-3 cords 18-2 SVO, SJTO cords, single multiple; cord capacity .125-.300 diameter with 10-3, 12-3, 14-3, 10-2, 12-2, cables; multiple 12-2 14-2 cables; single multiple flexible cords wire range .300 .600 with cables; 14-3, 14-2, 12-2 10-2 cables; single multiple flexible cords wire range .500 .850
.880
.795
.080
3201
.880
.795
.080
dia.
3202
1.100 1.005
.090
dia.
Press locking wedge into cavity which locks onto cable.
Temperature Rating: 105°C File Nos. 2884 U.L. File E-23017
Hole Size
Hole Size
Cat. 3201 ideal multiple flexible cords cable.
Figure
Figure
High impact thermoplastic. U.L. 94-V1. Features push-in design Captive locking wedge secures cable with single squeeze standard electrician's pliers. Provides excellent insulation, strain-relief high pull-out value.
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Nonmetallic Sheathed Cable Fittings
.400
Lock Connectors
Cat. Description Std. Ctn.
.580
NC501-SC NC501DBL-SC NC502-SC SB1216-SC
Lock Connector Double Lock Connector Lock Connector Twist Bushing Metal Studs
1.030
NC501-SC
Steel City
1.250 .580
1.000
2.485
1.120 1.300
NC501DBL-SC NC502-SC
1.315
.115
SB1216-SC
Clamp Type Connector Cast Zinc
Cat. Conduit Size (min.) Dimensions (in.) (max.) Std. Ctn.
NC-201 NC-202 NC-203 NC-204 NC-205 NC-206 File LR-12798 U.L. File E-17583
0.40" 0.50" 0.62" 0.50" 0.75" 0.90"
0.95" 1.10" 1.14" 1.38" 1.61" 2.04"
1.87" 1.84" 2.00" 2.28" 2.49" 3.35"
Clamp Type Connector Cast Zinc
Cat. Conduit Size (min.) Dimensions (in.) (max.) Std. Ctn.
NC-301 NC-302 NC-303 File LR-12798 U.L. File E-17583
(d"KO)
0.18" 0.41" 0.34"
0.64" 0.82" 0.94"
1.16" 1.87" 2.01"
1000
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Nonmetallic Sheathed Cable Fittings
Connectors Clamp Type, Non-Watertight Cast Zinc
Cat. Conduit Size (min.) Dimensions (in.) (max.) Std. Ctn.
NC-041 NC-051 NC-061
0.27" 0.54" 0.75"
0.75" 0.95" 1.12"
2.02" 2.50" 3.41"
Steel City
U.L. File E-15170-1b"-1d" U.L. File E-17583-2"
Duplex Clamp Type Connector Cast Zinc
Cat. Conduit Size (min.) Dimensions (in.) (max.) Std. Ctn.
with aluminum smooth extruded metal clad cable. (min. dia. .410) (max. dia. .500)
XC-210 XC-211-SC XC-222-SC
0.13" 0.24" 0.24"
0.65" 0.63" 0.63"
1.56" 1.59" 1.59"
Conduit/Cable
MAX. SIZE MIN. SIZE File LR-12798 U.L. File E-17909
1-1h"
10/2 14/2
.565 .425
.565 .425
10/2 14/2
max. min.
Saddle Type Connectors Cast Zinc
Cat. Dimensions (in.) Size (min.) (max.) Std. Ctn.
XC-2200-C
0.12"
0.63"
Tilt Connector Metallic Steel Electro-Galvanized
Cat. Conduit Size Std. Ctn.
NC-850 NC-851 NC-852 NC-853
f"-1 1-b" 1-d"
.050 .050 .062 .062
.950 1.250 1.625 1.970
1.312 1.750 2.125 2.500
.650 .760 .760 .785
8-32 8-32 10-32 10-32
1000
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Armored Cable/Flexible Metallic Conduit Fittings
Straight Connectors Straight Squeeze Type Connectors- Malleable Iron Stamped Steel Zinc Plated
Cat. Conduit Size Unit Qty. Std. Ctn.
XC-400 XC-401 XC-402 XC-403 XC-404 XC-405 XC-406 XC-407 XC-408 File E-17909 d"-f" File E-1275 1"-3" c"-f"-STEEL
K.O.)
Steel City
Straight Squeeze Type Connectors- Insulated Malleable Iron Stamped Steel Zinc Plated
Cat. Conduit Size Unit Qty. Std. Ctn.
XC-901 XC-902 XC-903 XC-904 XC-905 XC-906 XC-907 XC-908 d"-f"-STEEL
Clamp Straight Set, 90°, Duplex Connectors Angle Squeeze Type Connectors-Steel Malleable Iron Zinc Plated
Cat. Conduit Size Unit Qty. Std. Ctn.
XC-490 XC-491 XC-492 XC-493 XC-494 XC-495 XC-496 XC-497 XC-498
K.O.)
cast armored cable/flexible metallic conduit fittings combination fittings refer Steel City® Cast Conduit Fittings section. File E-17909 File E-1275 1"-3" c"-f"-STEEL
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Armored Cable/Flexible Metallic Conduit Fittings
Straight Squeeze Type Connectors Cast Zinc
Cat. Fig. Size (min.) Dimensions (in.) (max.) Std. Ctn.
Steel City
XC-269 XC-270 XC-272 XC-273 XC-274 XC-275 XC-276 XC-277 XC-278 XC-278A XC-2710
0.45" 0.74" 0.88" 1.10" 1.48" 1.68" 2.12" 2.71" 3.15" 3.20" 3.15"
0.60" 0.92" 1.10" 1.35" 1.65" 2.00" 2.47" 3.08" 3.60" 4.03" 4.25"
0.96" 1.43" 1.59" 1.60" 1.91" 2.12" 2.54" 2.88" 3.88" 5.04" 5.04"
U.L. File E-17909 U.L. File E-1275 1b"-2" File LR-12798 c"-1"
Straight Squeeze Type Connectors Insulated Cast Zinc
Cat. Fig. Size (min.) Dimensions (in.) (max.) Std. Ctn.
Figure
XC-870 XC-872 XC-873 XC-874 XC-875 XC-876 XC-877 XC-878 XC-879 XC-8710
0.74" 0.88" 1.10" 1.48" 1.68" 2.12" 2.71" 3.15" 3.20" 3.15"
0.92" 1.10" 1.35" 1.65" 2.00" 2.47" 3.08" 3.60" 4.03" 4.25"
1.43" 1.59" 1.60" 1.91" 2.12" 2.54" 2.88" 3.88" 5.04" 5.04"
U.L. File E-17909-d"-f" U.L. File E-1275-1b" File LR-12798
Figure
Figure
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Armored Cable/Flexible Metallic Conduit Fittings
Steel City® Cable
Cat. Size Range Steel Aluminum Interlocked Steel Aluminum Flex Std. Ctn.
XC-730 K.O. XC-731 K.O. Simple, one-piece installation with locknuts. Screw designed exceptional pullout resistance. Captive screw ensures that screw intact installation resists backing after installation. Corrosion-resistant, zinc-chromatic plating. Positive grounding. Vibration resistant screw design. listed certified. XC-732 K.O. XC-7300 K.O.
.450"/.610"
14/2 14/3 14/4 12/2 12/3 12/4 10/2 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 10/4 10/5 14/2 14/3 14/4 12/2 12/3 12/4 10/2
14/2 14/3 14/4 12/2 12/3 12/4 14/2 14/3 14/4 12/2 12/3 12/4
14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 10/4 10/5 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3
14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3
Steel
Steel
.450"/.610"
Steel City
.610"/.875"
14/2 14/3 14/4 12/2 12/3 12/4
.450"/.610"
U.L. File E-17909 File LR-12798
Simple, fast steps installing Steel City® Cable Lok.
Simply snap into place. locknuts required!
Insert cord twist screw. Connector tightens screw set.
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Armored Cable/Flexible Metallic Conduit Fittings
Clamp Type Connectors Cast Zinc
Cat. Fig. Conduit Size (min.) Dimensions (in.) (max.) Std. Ctn.
Steel City
Figure
XC-290 XC-291 "Threads" XC-292 XC-293 XC-294 XC-295 XC-296 XC-297 XC-298 XC-299 XC-2910
0.40" 0.65" 0.83" 1.27" 1.49" 1.51" 1.51" 2.45" 3.07" 3.63" 3.68"
0.63" 1.00" 1.25" 1.50" 1.85" 2.47" 2.47" 3.50" 4.02" 4.34" 5.17"
1.80" 2.08" 2.27" 2.60" 3.10" 6.05" 6.05" 7.75" 8.88" 12.75" 12.75"
U.L. File E-17909 File LR-18130M57
Insulated Cast Zinc
"Threads" Figure
Cat.
Fig.
Conduit Size
(min.)
Dimensions (in.) (max.)
Std. Ctn.
XC-890 XC-891 XC-892 XC-893 XC-894 XC-895 XC-896 XC-897 XC-898 XC-899 XC-8910
"Threads" Figure
0.40" 0.65" 0.77" 1.06" 1.34" 1.51" 1.51" 2.45" 3.07" 3.63" 3.68"
0.63" 0.97" 1.12" 1.40" 1.65" 2.47" 2.47" 3.50" 4.02" 4.34" 5.17"
1.81" 2.18" 2.38" 2.87" 3.93" 6.05" 6.05" 7.75" 8.88" 12.75" 12.75"
U.L. File E-17909 File LR-12798
"Threads" Figure
"Threads" Figure
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Armored Cable/Flexible Metallic Conduit Fittings
max. min.
Clamp Type Connector Cast Zinc
Cat. Conduit Size (min.) Dimensions (in.) (max.) Std. Ctn.
XC-280
0.18"
0.64"
1.16"
1000
U.L. File E-17909 File LR-18130M57
Duplex Clamp Type Connector Cast Zinc
with metal clad cable.
Cat. Conduit Size (min.) Dimensions (in.) (max.) Std. Ctn.
Steel City
1.56"
XC-210
0.13"
0.65"
File LR-18130M57
Cable Range
Cat. Continuous Corrugated Corrugated min. dia. max. dia. Aluminum Smooth Extruded min. dia. max. dia. Std. Ctn.
XC-280 XC-210
1-1h"
.510"
.345" .410"
.525" .500"
1000
Snap-In Connector Flexible Metal Conduit 105°C Rated
Cat. Conduit Size K.O. Size Unit Qty. Std. Ctn.
100-TB 100BP
1000
locknut required. special tools required. High impact thermoplastic with steel insert.
Flex Bushings Anti-Short
Cat. Fits Standard Cable Range Size Unit Qty. Std. Ctn.
IT-100-SC IT-101 IT-102 IT-103 IT-104 Packed polybags. Available bulk packed-10,000 carton. Plastic.
14/2-14/3-12/2 14/4-12/3-6/1-4/1 12/4-10/2-10/3-2/1 10/4-8/2-8/3-1/1 8/4-6/2-6/3-4/2-4/3-6/4
cast armored cable/flexible metallic conduit fittings combination fittings refer Steel City® Cast Conduit Fittings section. Ordered Bags
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Armored Cable/Flexible Metallic Conduit Fittings
max. min.
Straight Screw Connectors Cast Zinc Noninsulated
Cat. Size (min.) Dimensions (in.) (max.) Std. Ctn.
max. min.
XC-220 XC-221
0.38" 0.74" 0.74"
0.63" 0.94" 0.94"
0.84" 1.46" 1.46"
1000
XC-220
XC-221 XC-821
XC-821
Steel City
max. min.
XC-220 XC-221: U.L. File E-17909 U.L. File E-1275 XC-821: U.L. File E-1275
Flex Connectors, Saddle Type Cast Zinc
Cat. Size (min.) Dimensions (in.) (max.) Std. Ctn.
XC-2200-C
0.12"
0.63"
0.98"
Screw-In Connectors Cast Zinc Noninsulated
Cat.
Dimensions (in.) Size
Std. Ctn.
XC-240 XC-241 XC-242 XC-243 XC-244 XC-245 XC-246
1.31" 1.38" 1.62" 1.94" 2.12" 2.31" 2.58"
0.92" 0.92" 1.12" 1.37" 1.75" 2.13" 2.67"
U.L. File E-1275 File LR-18130M57 c"-d"
Screw-In Connectors Cast Zinc Insulated
Cat. Dimensions (in.) Size Std. Ctn.
XC-840 XC-841 XC-842 XC-843 XC-844 XC-845 XC-846
1.31" 1.38" 1.62" 1.94" 2.12" 2.31" 2.58"
0.92" 0.92" 1.12" 1.37" 1.75" 2.13" 2.67"
U.L. File E-1275 File LR-18130M57 c"-d"
Screw-In Couplings Cast Zinc
Cat.
Dimensions (in.) Size
Std. Ctn.
XK-241 XK-242 XK-243 XK-244 XK-245 XK-246 U.L. File E-1275
1.81" 2.09" 2.41" 2.75" 3.05" 3.28"
0.92" 1.12" 1.37" 1.81" 2.12" 2.67"
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Cable Straps, Cable Caps
Service Cable Straps Hole
Cat. Fits Cable Shelf Ctn. Ship Case Std. Ctn.
SE100 SE101 SE102 SE103
3#8, 3#6, 3#3, 3#1, 3#0, 3#1/0, 3#2/0 3#3/0, 3#4/0
1000 1000
1000 1000
Steel City
Service Cable Straps Hole
Cat. Fits Cable Shelf Ctn. Ship Case Std. Ctn.
SE900 SE901 SE902 SE903
3#8, 3#6, 3#3, 3#1, 3#0, 3#1/0, 3#2/0 3#3/0, 3#4/0
1000 1000
1000 1000
Service Cable Caps Oval
Cat. Fits Cable Dimensions (Inches) Std. Ctn.
50130 50130A
With Split Insulator
2/0-3 4/0-3 3#3-2 3#3/0-4/0
5.00 6.75 2.37 4.93
3.31 4.62 2.12 3.12
4.75 6.00 2.25 3.75
SC1000 SC2001
Extra Large Body Additional Wiring Space.
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Service Entrance Fittings
Aluminum Service Caps Clamp Type Rigid/Intermediate Thinwall
Cat. Conduit Size Hole Size Std. Ctn.
Steel City
SH-101 SH-102 SH-103 SH-104 SH-105 SH-106 SH-107 SH-108 SH-109 SH-110 File LR-12798 U.L. File E-22753
2(c") 3(u") 2(k") 3(d") 2(N") 3(e") 2(x") 1(k") 3(f") 2(f") 3(1") 1(w") 3(g") 1(1") 3(1j") 4(1a") 3(1f") 4(1f") 2(a") 4(1f") 2(1a")
Service Entrance Fittings
Cat. Trade Size Std. Ctn.
ASLB-1 ASLB-2 ASLB-3 ASLB-4 ASLB-5 ASLB-6 DASLB-1 DASLB-2 DASLB-3
Service Entrance Fittings Standard
Cat. Trade Size Std. Ctn.
ASLB-1 ASLB-2 ASLB-3 ASLB-4 ASLB-5 ASLB-6
TYPE
Service Entrance Fittings Standard
Cat. Trade Size Std. Ctn.
SALB-7 SALB-8 SALB-9 SALB-10
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Grounding Clamps/Connectors
Ground Clamps Cast Zinc Alloy Armored Ground Wire
Cat. Conduit Conduit Size Std. Ctn.
GA-203 U.L. File E-10661 Two-screw ground connection armored ground wire.
Ground Clamps Cast Zinc, Brass Colored
Cat. Conduit Conduit Size Std. Ctn.
Steel City
GC-203-B
Water-Tight Connectors
Cat.
Trade Size
Fits Cable
Rubber Grommet Opening
Std. Ctn.
Type Style Flat; Insulating Conductors, Bare.
WT-203A WT-203B WT-203C WT-204A WT-204B WT-204C WT-204D WT-205A WT-205B WT-205C WT-206A WT-206B WT-206C WT-206D WT-206E UF-201 UF-202
3#1/0 3#1/0 3#2/0 3#2/0 3#3/0 3#2/0 3#3/0 3#1/0 3#2/0 3#2/0 3#3/0 3#2/0 3#3/0 3#4/0 3#4/0 2#14 3#14
.500 .563 .625 .625 .580 .660 .750 .735 .875 .938 .735 .875 .938 .890 1.063 .210 .220
.750 .844 .938 1.000 .960 1.090 1.125 1.240 1.375 1.438 1.240 1.375 1.438 1.550 1.688 .440 .660
Underground Feeder Cable
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Gutter Connectors/Cable Protector Cable Clip
Gutter Connectors
1-2o"
Steel City
Replaces conventional method nipple, locknuts bushings interconnect panel boxes other type enclosures troughs gutters. Gutter connectors provide automatic uniform spacing with threads showing. Conventional installation requires that nipple used with double locknuts
both ends with bushing locknut each end. Also, when using more nipples, time consumed adjusting nipples straight alignment enclosure. Gutter connectors eliminate these time consuming methods. three piece connector requires tightening only locknut.
Gutter Connectors Straight
Cat. Conduit Size Dia. Std. Ctn.
Locknut Spacer
UC-101 UC-102 UC-103 UC-104 UC-105 UC-106 U.L. File E-1275
Fitting
Pieces Steel/Zinc Plated
Cable Protector
Cat. Description Std. Ctn.
CP-1
Steel
Cable Clip
Cat.
Description
Std. Ctn.
NS-100
Steel
1000
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Beam Clamps Mounting Pipe Conduit
Conduit/Pipe Beam Clamps
Cat. Size Clamp Steel Dimensions Inches O.D. Conduit Pipe Nom. Conduit Pipe Size Std. Ctn.
Series
RCS-1/2 RCS-3/4 RCS-1 RCS-1-1/4 RCS-1-1/2 RCS-2
Clamp Malleable Iron
.840 1.050 1.315 1.660 1.900 2.375
Steel City
mounting pipe conduit right angles beam. SS316 Suffix Stainless Steel. Suffix Galvanized.
RC-3/8 RC-1/2 RC-3/4 RC-1 RC-1-1/4 RC-1-1/2 RC-2-SC RC-2-1/2 RC-3 RC-3-1/2 RC-4-SC
Clamp Malleable Iron
.675 .840 1.050 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500
Series
mounting pipe conduit vertically across beam. Suffix Galvanized.
EC-1/2 EC-3/4 EC-1 EC-1-1/4 EC-1-1/2 EC-2 EC-2-1/2
Clamp Malleable Iron
.840 1.050 1.315 1.660 1.900 2.375 2.875
PC-3/8 PC-1/2 PC-3/4 PC-1 PC-1-1/4 PC-1-1/2 PC-2 PC-2-1/2 PC-3 PC-3-1/2 PC-4
Series
.675 .840 1.050 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500
mounting pipe conduit parallel beam. Suffix Galvanized.
2003 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Conduit Pipe Hangers
Series Conduit Pipe Hangers Without Bolt
Cat. Size (in.) Rigid Conduit Pipe Dimensions (in.) (dia.) Load Rating Std. Ctn.
Without Bolt
Steel City
Steel City Hanger Bolts include combination Slot-Phillips Head.
6H0-T 6H1-T 6H2-1/2 6H3-SC
.045 .045 .045 .045 .045 .045 .045 .071 .071 .071 .071 .071 .071
hanging conduit (rigid EMT) pipe. series hangers fast, easy economical use. fastened directly #500 beam clamp through hole base hanger means 1/4-20 stove bolt suspended 1/4" hanger rod.
suffix part number stainless steel. Load rating lbs. with safety factor Available with without closure bolt. Standard finishes: electrogalvanized Type Stainless Steel.
Series Conduit Pipe Hangers With Bolt
Cat. Size (in.) Rigid Conduit Pipe Dimensions (in.) (dia.) Load Rating Std. Ctn.
6H0-B 6H0-TB 6H1-B 6H1-TB 6H2-B 6H2-1/2-B 6H3-SC-B 6H4-B 6H5-B 6H6-B 6H7-B 6H8-B 6H9-B
.045 .045 .045 .045 .045 .045 .045 .071 .071 .071 .071 .071 .071
Without bolt.
6H-B With bolt nut.
suffix part number stainless steel. (not listed.) Load rating lbs. with safety factor Available with without closure bolt. Standard finishes: electrogalvanized Type Stainless Steel.
6H-T Threaded without bolt.
6H-TB Threaded with bolt.
Beam Clamp
Cat. Size Tapped Std. Ctn.
BC1-TB BC2-TB Material: Steel Finish: Zinc Plated
b-20 c-16
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Beam Clamps/Threaded Rod/Rod Coupling
Beam Clamps Malleable Iron, Electroplated Finish
Cat. Base Size Inches Opening Inches Tapping Base Back Holes Load Rating Std. Ctn.
511-SC 500-SC 503-SC
b-20 10-24 b-20 10-24 j-18 c-16 d-13 d-13 d-13
1300 1300 1700 1700
Steel City
Safety Factor Loan Ratings based bottom hole Beam Clamp. File LR-52208
R-Series Continuous Thread Galvanized
Cat. Size Ultimate Load Lbs. Root Area Thread Data Pressure Piping Nominal Max. Safe Pipe Size Load 450° Std. Ctn.
R628-6 R638-6 R648-6 R1028-10 R1038-10 R1048-10
b-20 c-16 d-13 b-20 c-16 d-13
1900 3500 1900 3500
.027 .068 .126 .027 .068 .126
1130 1130
Load Ratings based safely factor three.
H-195 Steel Coupling
Cat. Size Dimensions Inches Std. Ctn.
H-195-1/4 H-195-3/8 H-195-1/2 H-195-5/8
1000
2002 Thomas Betts Corporation. Specifications subject change without notice.
www.tnb.com
Building century trust!
Steel City.
You've told what your customers they work what they need better, faster, easier job. we've used your feedback make Steel City® most versatile trusted brand industry! line bigger stronger than ever. Steel City® boxes include exclusive features help simplify speed installations. We've upgraded extensive line
SH2346 Box-to-Stud Bracket Unique side brace allows part number attach boxes 1/2," 1/2," metal wood studs. (Competition needs three.)
Steel City Fittings added convenience reliability. we've added line over Steel City Spring Steel Fasteners that meet current test requirements. Thomas Betts together we're building century trust. technical information about product Steel City line, call 1-888-862-3289.
Series Conduit Drop Wire Fasteners Larger finger tab, better leverage, makes easier secure MC/AC cables conduit drop wire, plain threaded rods, flanges.
Steel City Superstrut Union Bowers

Other recent searches


SM6453AB - SM6453AB   SM6453AB Datasheet
SD400C - SD400C   SD400C Datasheet
S6B0723 - S6B0723   S6B0723 Datasheet
PCI08-DK - PCI08-DK   PCI08-DK Datasheet
MIC2196 - MIC2196   MIC2196 Datasheet
BLV2044 - BLV2044   BLV2044 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive