GP1FA551TZ/ GP1FA551RZ High speed transmission high quality audio


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



GP1FA551TZ/GP1FA551RZ
GP1FA551TZ/ GP1FA551RZ
High speed transmission high quality audio signal such players amplifiers. Signal transmission speed:MAX.13.2Mbps (NRZ signal) Uni-directional data transmission using plastic optical fiber cable optical receiver directly connectable TTL, OPIC
High Transmission Speed Type Fiber Optic Transmitter/Receiver
Outline Dimensions
10.1
(Unit
Protection fixing hole
Applications
players players players
Absolute Maximum Ratings
Parameter Supply voltage Output current (GP1FA551RZ) Input voltage (GP1FA551TZ) Operating temperature Storage temperature Soldering temperature
times less)
(Ta=25°C)
2.54
2.54
Symbol Rating Unit -0.5 +7.0 (Source current) (Sink current) -0.5 +0.5 Topr Tstg Tsol
10.6 Internal equivalent circuit
GP1FA551RZ
Amp. Amp. Amp.
Comp output circuit
Amp.
GP1FA551TZ Drive
4±0.5
OPIC light detector
Vout
GaAlAs Drive Silicone
Recommended drilling viewd from soldering face (Unspecified tolerance ±0.1mm) +0.1 2-2.0-0 2.54 2.54
Unspecified tolerance ±0.3mm
3-0.8
"OPIC"(Optical trademark SHARP Corporation. OPIC consists light-detecting element signalprocessing circuit integrated onto single chip.
Notice
absence confirmation device specification sheets, SHARP takes responsibility defects that occur equipment using SHARP devices shown catalogs, data books, etc. Contact SHARP order obtain latest device specification sheets before using SHARP device. Internet Internet address Electronic Components Group http://www.sharp.co.jp/ecg/
GP1FA551TZ/GP1FA551RZ Recommended Operating Conditions (GP1FA551TZ)
Parameter Operating supply voltage Operating transfer rate
signal, duty
Symbol
MIN. 4.75
TYP.
MAX. 5.25 13.2
(Ta=25°C) Unit Mbps
Recommended Operating Conditions (GP1FA551RZ)
Parameter Operating supply voltage *3*4 Operating transfer rate Input optical power level Symbol MIN. 4.75 -24.0 TYP. MAX. 5.25 13.2 -14.5
(Ta=25°C) Unit Mbps
above operating transfer rate value when signal, "0101." continuous signal duty transmitted output (H/L level) GP1FA551RZ fixed constantly when receivers modulating light (including light, input light) less than 0.1Mbps Peak emission value
Electro-optical Characteristics (GP1FA551TZ)
Parameter Symbol Conditions
MIN.
(Ta=25°C, Vcc=5V) TYP. MAX. Unit
Peak emission wavelength Optical output coupling with fiber Dissipation current High level input voltage level input voltage LowHigh delay time HighLow delay time Pulse width distortion Jitter
tpLH tpHL
Refer Fig.1 Refer Fig.2 Refer Fig.2 Refer Fig.2 Refer Fig.3 Refer Fig.3 Refer Fig.3 Refer Fig.3
Electro-optical Characteristics (GP1FA551RZ)
Parameter Symbol Conditions
MIN.
(Ta=25°C, Vcc=5V) TYP. MAX. Unit
Peak sensitivity wavelength Dissipation current High level output voltage level output voltage Rise time Fall time LowHigh delay time HighLow delay time Pulse width distortion Jitter
tpLH tpHL
Refer Fig.4 Refer Fig.5 Refer Fig.5 Refer Fig.5 Refer Fig.5 Refer Fig.5 Refer Fig.5 Refer Fig.5 Refer Fig.6, PC=-14.5dBm Refer Fig.6, PC=-24dBm
Mechanical Characteristics
Parameter Insertion force, withdrawal force Symbol Conditions Initial value when GP1C331 used. MIN. TYP. MAX. Unit
GP1FA551TZ/GP1FA551RZ Fig.1 Measuring Method Optical Output Coupling with Fiber
Standard optical fiber cable GP1FA551TZ Unit measured optical power meter must calibrated have wavelength sensitivity 660nm (0dB=1mW) Optical power meter (Anritsu) ML93B
Note VCC; 5.0V (State operating) bundle standard fiber optic cable, make into loop with diameter D=10cm more (The standard fiber optic cable will specified elsewhere.)
Fig.2 Measuring Method Intput Voltage Supply Current
Standard fiber optic cable GP1FA551TZ Unit measured
Optical power meter (Anritsu) ML93B optical power meter must calibrated have wavelength sensitivity 660nm (0dB=1mW)
Input conditions judgement method Conditions VIN=2.1V more VIN=0.8V less Judgement method -21PC-15dBm, ICC=13mA less PC-36dBm, ICC=13mA less
Note VCC=5.0V (State operating)
GP1FA551TZ/GP1FA551RZ Fig.3 Measuring Method Pulse Response Jitter
Standard fiber optic cable GP1FA551TZ Unit measured Input Input signal 6.6Mbps biphase mark PRBS signal Oscilloscope Tektronix 7834 7934 type Trigger;CH1 Storage mode Standard receiver Output signal
Input signal tPLH tPHL
Standard receiver output
Parameter
Symbol
Conditions
LowHigh delay time HighLow delay time Pulse width distortion LowHigh jitter HighLow jitter
tpLH tpHL
Refer above mentioned prescription Refer above mentioned prescription tw=tpHL-tpHL trigger rise input signal measure jitter rise output trigger fall input signal measure jitter fall output
Notes waveform write time shall allow waveform distorted increasing brightness much VCC=5.0V (State operating) probe oscilloscope must more than less than 10pF
Fig.4 Supply Current
Supply voltage Fiber coupling light output Standard transmitter input signal Input conditions VCC=5.0V PC=-14.5dBm 13.2Mbps NRZ, Duty 6.6Mbps biphase mark PRBS signal
Fiber optic cable Standard transmitter meter GP1FA551RZ Unit measured Vout
Measuring method Measured ammeter average amperage)
Input
GP1FA551TZ/GP1FA551RZ Fig.5 Measuring Method Output Voltage Pulse Response
Fiber optic cable Standard transmitter Input GP1FA551RZ Unit measured VOUT
13.2Mbps NRZ, Duty
Tektronix 7834 7934 type Oscilloscope
Test item Test item High pulse delay time High pulse delay time Rise time Fall time Pulse width distortion tw=tpHL-tpLH High level output voltage level output voltage
Notes
Symbol tpLH tpHL
Standard transmitter Input signal (CH1)
GP1FA551RZ Output signal (CH2)
VCC=5.0V (State operating) fiber coupling light output -14.5dBm/-24dBm probe oscilloscope must more than less than 10pF RSI, RSO:Standard load resistance (RSI:3.3k, RSO:2.2k) output (H/L level) GP1FA551RZ fixed constantly when receives modulating light (including light, input light) less than 0.1Mbps
tpLH
tpHL
GP1FA551TZ/GP1FA551RZ Fig.6 Measuring Method Jitter
Fiber optic cable Standard transmitter GP1FA551RZ Unit measured VOUT
Oscilloscope Input Tektronix 7834 7934 type Trigger Storage mode Sweep AUTO/NORM
Input signal 6.6Mbps biphase, PRBS signal
Test item Test item Symbol Jitter Jitter
Test condition trigger rise input signal measure jitter rise output trigger fall input signal measure jitter fall output
Input signal
Notes fiber coupling light output -14.5dBm/-24dBm RSI, RSO:Standard load resistance (RSI:3.3k, RSO:2.2k) waveform write time shall allow waveform distorted increasing brightness much VCC=5.0V (State operating) probe oscilloscope must more than less than 10pF
GP1FA551RZ output
Application Circuits
NOTICE
qThe circuit application examples this publication provided explain representative applications SHARP devices intended guarantee circuit design license intellectual property rights. SHARP takes responsibility problems related intellectual property right third party resulting from SHARP's devices. qContact SHARP order obtain latest device specification sheets before using SHARP device. SHARP reserves right make changes specifications, characteristics, data, materials, structure, other contents described herein time without notice order improve design reliability. Manufacturing locations also subject change without notice. qObserve following points when using devices this publication. SHARP takes responsibility damage caused improper devices which does meet conditions absolute maximum ratings used specified relevant specification sheet meet following conditions: devices this publication designed general electronic equipment designs such Personal computers Office automation equipment Telecommunication equipment [terminal] Test measurement equipment Industrial control Audio visual equipment Consumer electronics (ii)Measures such fail-safe function redundant design should taken ensure reliability safety when SHARP devices used connection with equipment that requires higher reliability such Transportation control safety equipment (i.e., aircraft, trains, automobiles, etc.) Traffic signals leakage sensor breakers Alarm equipment Various safety devices, etc. (iii)SHARP devices shall used connection with equipment that requires extremely high level reliability safety such Space applications Telecommunication equipment [trunk lines] Nuclear power control equipment Medical other life support equipment (e.g., scuba). qContact SHARP representative advance when intending SHARP devices "specific" applications other than those recommended SHARP when unclear which category mentioned above controls intended use. SHARP devices listed this publication fall within scope strategic products described Foreign Exchange Foreign Trade Control Japan, necessary obtain approval export such SHARP devices. qThis publication proprietary product SHARP copyrighted, with rights reserved. Under copyright laws, part this publication reproduced transmitted form means, electronic mechanical, purpose, whole part, without express written permission SHARP. Express written permission also required before this publication made third party. qContact consult with SHARP representative there questions about contents this publication.

Other recent searches


VAC-1 - VAC-1   VAC-1 Datasheet
RTC-72421 - RTC-72421   RTC-72421 Datasheet
72423 - 72423   72423 Datasheet
M1000 - M1000   M1000 Datasheet
AKC-11 - AKC-11   AKC-11 Datasheet
AKC-32 - AKC-32   AKC-32 Datasheet
AKC-17B - AKC-17B   AKC-17B Datasheet
AKC-17C - AKC-17C   AKC-17C Datasheet
ADP3210 - ADP3210   ADP3210 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive