VI-RAMTM, VE-RAM (RoHS Compliant) Ripple Attenuator Modules


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Factorized Power
VI-RAMTM, VE-RAM (RoHS Compliant)
Ripple Attenuator Modules
Features
RoHS compliant versions) Reduces output ripple Compatible with VI-200/VI-J00-
based product: output Full attenuation adjustments required 93-99% efficiency Converter sense, trim, overvoltage overcurrent retained Size: 2.28" 2.4" 0.5" (57,9 61,0 12,7) Marked
VI-RAM Specifications
(typical 25°C, nominal line, load unless otherwise specified)
Parameter Output Noise Ripple VI-200 VI-J00 Input Voltage Range Output Voltage Deviation Min. Typ. Max. 0.5% From output voltage VI-200 source which VI-RAM will connected max. allowable baseplate temperature 10Amps 20Amps 30Amps (overload) Remarks From full rated output current source converter full load
Product Highlights
Ripple attenuator modules connected VI-200 VI-J00 converters, FlatPACs, MegaPACs, MasterModules MegaModules, with output voltages from 50V, limit output noise less than peak-to-peak loads 20A. Combining active passive filtering, VI-RAM attenuates both frequency input power source fundamental harmonics, high frequency switching components frequency range MHz, while exhibiting efficiencies 93-99%. adjustments required, remote sense output voltage trim features retained. member Vicor's high-power density, high performance, component-level power building blocks, VI-RAM offers power systems architect single, flexible, component-level solution almost "clean power" problem. same time, VI-RAM eliminates space, efficiency, weight penalties associated with linear power sources, stability, efficiency, adjustment penalties associated with external "add filters conventional switchers.
Full Load Current Overload Current Voltage Drop
10Amps 20Amps 30Amps
Isolation Size Weight
0.34 0.41 0.34 0.44 0.34 0.75 Dissipation voltage drop) (Load current 500VRMS Input/Output baseplate 2.28" 2.4" 0.5" (57,9 61,0 12,7) Ounces Grams) SlimMod FinMod packages available
Electrical Considerations
Transient Response Dynamic Range: Full rated noise attenuation will maintained VI-RAM output step load changes rated output current source converter, with VI-RAM exhibiting underdamped output excursion less than Some degradation noise attenuation during transient response period following step exhibited larger load changes. Adding output capacitance VI-RAM will improve rejection over larger dynamic range.
Sense Connection: Sense-in sense-out connections provided VI-RAM. Sense-in
connections must connected corresponding sense connections Vicor converter. Sense-out pins VI-RAM must connected between VI-RAM power-output pins, point load.
Output Load Characteristics: When used combination with Vicor DC-DC converters, with
sense leads connected, VI-RAM will stable non-inductive load.
Voltage Drop: Below full load, input output Voltage Drop controlled essentially constant voltage which appears between -OUT terminals. overload voltage drop will rise current increases. tens millivolts appears between +OUT terminals. Care should taken connect terminals (i.e. through scope probe returns, grounds, etc.), attenuation will adversely affected.
Product Grade Specifications
Parameter 10A) VI-RAM-E1 20A) VI-RAM-E2 Storage Temp. -20°C +105°C Operating Temp. -10°C +100° (Baseplate) VI-RAM-C1 VI-RAM-C2 -40°C +105°C -25°C +100°C VI-RAM-I1 VI-RAM-I2 -55°C +105°C -40°C +100°C VI-RAM-M1 VI-RAM-M2 -65°C +105°C -55°C +100°C
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-RAM Ripple Attenuator Modules
Rev.1.1
Page
your site VICOR www.vicorpower.com
Attenuation Frequency
Attenuation Frequency (typical)
Input converter V/cm
Output from mV/cm
Connection Diagram
.01uF
.01uF Gate Gate Load
VI-200
Trim .01uF
VI-RAM
.01uF
Mechanical Drawing
2.28 (57,9)
0.49 (12,4)
0.30±0.015 (7,6)±(0,38)
1.30 (33,0) 0.65 (16,5)
Standard 0.080 places Solder plate over copper alloy
RoHS 0.080 places Matte over copper alloy
2.10 (53,4) 1.40 1.00 (35,6) (25,4) (17,8) (10,2) .35± .015 (8,9)±(0,38) (3,8) (3,8) FULL Standard 0.040 (1,0) places Solder plate over copper alloy Product this surface 0.22 (5,6) Min. (7,6) Min. RoHS
Function +Sense -Sense +Out +Sense -Sense -Out
VI-RAM
0.040 (1,0) places Matte over copper alloy 2.40 (61,0) 1.75 Max. (44,4)
1.90 (48,3)
(12,7) (3,0)
+.030 (0,76) -.000 (0,00)
Aluminum Base
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-RAM Ripple Attenuator Modules
Rev.
1/06
your site VICOR www.vicorpower.com

Other recent searches


TMS320VC5502 - TMS320VC5502   TMS320VC5502 Datasheet
R1200F - R1200F   R1200F Datasheet
R3000F - R3000F   R3000F Datasheet
MJLF147-X - MJLF147-X   MJLF147-X Datasheet
LM5007 - LM5007   LM5007 Datasheet
CLC450 - CLC450   CLC450 Datasheet
AD7575 - AD7575   AD7575 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive