| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Control Terminal Model name ZM-42/43/52/72/82 User's Ma
Top Searches for this datasheetVersion Produced 2001 Control Terminal Model name ZM-42/43/52/72/82 User's Manual/Hardware version (ZM-82) Thank purchasing Control Terminal ZM-42/43/52/72/82 series. Please read instruction manual carefully, operate product with full understanding functions operation methods. details each Control Terminal functions panel editing methods, please refer instruction manual screen edit software. ZM-71SE Instruction Manual User's Manualt(Tutorial) Caution this user's manual, ZM-42/43/52/72/82 series referred follows. Expression this manual ZM-** Series name ZM-42/43/52/72/82 Note have created this instruction manual carefully, case have some doubts comments this manual, please contact affiliated store where bought this product directly company. forbidden copy content materials this book, neither partially fully. Please understand that content this manual altered amelioration without notifications. Safety precautions Read this manual attached documents carefully before installation, operation, maintenance checking order machine correctly. Understand machine knowledge, safety information, cautions before starting use. this instruction manual, safety precautions ranked into "danger" "caution" follows. Danger Caution Wrong handling possibly lead death heavy injury. Wrong handling possibly lead medium light injury. Even case Caution serious result experienced depending circumstances. Anyway, important points mentioned. sure observe them strictly. picture signs Prohibit Compel explained below. means don'ts. example, prohibition disassembly indicated means must. example, obligation grounding indicated Installation Caution environments specified catalog, instruction manual, user's manual. Electric shock, fire malfunction caused when used environments high temperature, high humidity, dusty corrosive atmosphere, vibration impact. Install according manual. Wrong installation cause drop, trouble malfunction. Never admit wire chips foreign matter fire, trouble malfunction caused. Wiring Compel sure ground. Unless grounded, electric shock malfunction caused. Caution Connect rated power source. Connection wrong power source cause fire. Wiring should done qualified electrician. Wrong wiring lead fire, trouble electric shock. Danger Don't touch terminal while power being supplied have electric shock. Assemble emergency stop circuit interlock circuit outside ZM-42/43/52/72/82. Otherwise breakdown accident damage machine caused trouble ZM-42/43/52/72/82. Maintenance Prohibit Don't disassemble modify modules. fire, breakdown malfunction caused. Contents Hardware Specifications Special Features Notes Usage System Composition Names Components Dimensions Panel Cut-out 1-11 Mounting Procedure 1-16 Wiring 1-17 Specifications 1-19 Serial Connector (CN1) 1-26 Setting Switches 1-28 Modular Jack 1-29 Code Reader Interface 1-30 Printer Interface (CN2) 1-31 Video Interface 1-32 Connection 1-33 Operation ZM-** Main Menu 1-40 Function Switches 1-51 Terminal Converter (ZM-1TC) 1-52 Expansion module (ZM-322M) 1-54 Card Recorder (ZM-1REC) 1-56 Cable transporting panel (ZM-80C) 1-57 Printer Cable (ZM-80PC) 1-58 2Port Adapter (ZM-1MD2) 1-59 Expansion Memory (ZM-4EM) 1-63 Expansion Memory (ZM-43EM) 1-64 Expansion Memory (ZM-43SM/80SM) 1-66 Connection Link Units Sharp MITSUBISHI MITSUBISHI 2-14 MITSUBISHI 2-18 MITSUBISHI 2-20 MITSUBISHI 2-23 MITSUBISHI 2-26 MITSUBISHI 2-27 OMRON 2-29 OMRON 2-34 HITACHI 2-35 HITACHI 2-38 Matsushita 2-41 YOKOGAWA 2-44 YOKOGAWA 2-46 YASKAWA 2-49 YASKAWA 2-52 TOYOPUC 2-54 FUJI 2-57 FUJI 2-60 FUJI 2-63 FUJI 2-65 Koyo 2-67 Allen-Bradley 2-72 Allen-Bradley 2-77 Fanuc 2-81 Fanuc 2-83 TOSHIBA 2-85 TOSHIBA MACHINE 2-87 SIEMENS 2-89 SIEMENS 2-91 SIEMENS 2-93 SIEMENS 2-95 SIEMENS 2-97 Shinko 2-99 SAMSUNG 2-101 KEYENCE 2-103 KEYENCE 2-105 KEYENCE 2-108 2-110 FANUC 2-113 FATEK AUTMATION 2-115 IDEC 2-117 MODICON 2-119 YAMATAKE 2-121 TAIAN 2-123 Hardware Specifications Special Features Notes Usage System Composition Names Components Dimensions Panel Cut-out Mounting Procedure Wiring Specifications Serial Connector (CN1) Setting Switches Modular Jack Code Reader Interface Printer Interface (CN2) Video Interface Connection Operation ZM-** Main Menu Function Switches Terminal Converter (ZM-1TC) Expansion module (ZM-322M) Card Recorder (ZM-1REC) Cable transporting panel (ZM-80C) Printer Cable (ZM-80PC) 2Port Adapter (ZM-1MD2) Expansion Memory (ZM-4EM) Expansion Memory (ZM-43EM) Expansion Memory (ZM-43SM/80SM) Special Features Special Features Control Terminal ZM-42/43/52/72/82 series programmable indication equipment support tool that display touch panel functions. They communicate programmable controller (thereafter programless, display variety functions well inputting data touch panel already programmed panel data. select size panel such inch display, inch display, 10.4 inch display 12.1 inch display, according your needs. Some special features include: free position switch, 128-color display, functions better quality representation manipulation including debug function realized exclusive simulation software. They also subject adapt variety needs, such special features realized putting support tool such expansion memory card reader. 128-color Display 128-color display which makes colorful expression possible realized. only drawings also bitmap files clearly displayed. (ZM-52/72/82) Data Sheet Printing Function possible make original data sheet screen panel editor editing software). Daily reports monthly reports that operator must fill printed instant. Sampling Function possible carry battery back history data expansion memory(ZM-43SM/80SM). Macro Function With this function, ZM-42/43/52/72/82 series make programs which previously produced Multi Window Function three windows displayed simultaneously screen. easy move delete displayed windows. Video Function ZM-** series connected video camera, image which taken video camera displayed directly screen ZM-** series Correspondense Ethernet, FL-net connectable with Ethernet FL-net Ethernt module ZM-80NU mounted.(ZM-43/52/72/82) Ethernet high-speed response realized programless connection betwen ZM-43/52/72/82 PC(*). communication with server between ZM-43/52/72/82s also possible without server.Moreover, screen data transmission also possible easy high speed through server. (*Connection restricted Ethernet correspondence PC.) FL-net connects with FL-net which introduction progressing open field network, high-speed communication possible each controller masterless token system. Expansion memory Extension screen data ZM-4EM(for ZM-52/72/82) ZM-43EM(for ZM-43), ZM-80SM(for ZM-52/ 72/82) ZM-43EM(for ZM-43) backup internal memory. Ladder monitor ability carried ladder figure display network possible. utilizable shortening troubleshooting down time. (Refer ZM-42/52/72/82 User's Manual Ladder Monitor version.) Character expression Gothic font Gothic font sizes chosen points. Moreover, since used numerical data, unusual display, etc., power expression improved. combined with present 16/32 font impossible. expansion memory needed. screen edit software ZM-71SE correspondence version V1.2.0.0. names ZM-42/43/52/72/82 series, please refer System Composition" chapter. Notes Usage Notes Usage Environmental Limits Never install Control Terminal place where impacts vibrations transmitted. Control Terminal ambient temperature relative humidity %RH. (But, ZM-72D/T multi-color display used Install forced conditioner maintain ambient temperature when higher than above mentioned range. Avoid place which there possibility that water, corrosive gas, flammable gas, solvents coolants, grinding come contact with unit. Never install unit place where dust, salt metallic particles present. YOUZAI Vent Locations Avoid places where moisture easily condense sudden temperature changes. Secure sufficient space around Control Terminal ventilation. Avoid direct sunlight. Never attach Control Terminal apparatus generating high levels heat (heater, transformer, large-capacity resistor, etc.). Notes Usage Never install Control Terminal same compartment high-voltage equipment. unit should least away from highvoltage lines power cables. Securely fasten lock every connector each cable. Double-check this before turning power Usage emergency stop circuit must composed external relay circuit with start signal Control Terminal built create switches Control Terminal used case emergency. environment, Control Terminal generate large amount static electricity. Therefore, before touching unit, touch grounded metallic section discharge static electricity. Alcohol BENZINE Switch used emergency Emergency Stop Control Terminal glass screen. Never drop subject unit strong impacts. Application thinner discolor Control Terminal. alcohol benzine available commercially cleaning. Never remove printed circuit board from Control Terminal. (This will harm unit.) Tighten mounting screws with following torques. Type ZM-42/43/52 ZM-72/82 Screw Screw Size Torque 0.29~0.49 0.49~0.69 Note :Never fasten these screws tightly, otherwise cover Control Terminal deformed. System Composition Screen edit software series ZM-71SE System Composition System Composition Model Indication Peripheral Equipment System Composition following illustration shows possible system configurations using ZM-**. Transferring screen data ZM-80C During operation (Link communication) RS-232C/RS-422 Creating screens Personal Computer ZM-** During operation (General serial communication) RS-232C/RS-422 Link module Transferring screen data ZM-80C Transferring screen data Memory manager /Data logging ZM-1REC Cable Exclusive cable General-purpose computer Video camera Card Recorder ZM-1REC Printer Cable ZM-80PC code reader connecting cable ZM-80BC code reader Printer models that possess video input interface function ZM-72TV/TVC/TSV/TSVC ZM82TV/TVC. System Composition Control Terminal Classification ZM-42 series Model Name ZM-42D ZM-42L ZM-43T ZM-43 series ZM-43D ZM-43L ZM-52 series ZM-52D ZM-72T ZM-72TC ZM-72TV ZM-72TVC ZM-72 series ZM-72TS ZM-72TSC ZM-72TSV ZM-72TSVC ZM-72D ZM-72DC ZM-82T ZM-82TC ZM-82 series ZM-82TV ZM-82TVC ZM-82DC Specifications inches color, dots inches monochrome, dots inches monochrome, dots inches color, dots inches monochrome, dots inches color, dots 10.4 inches color, dots 10.4 inches color, dots, memory card included 10.4 inches color, dots, video Input included 10.4 inches color, dots, video Input memory card included 10.4 inches color, dots 10.4 inches color, dots, memory card included 10.4 inches color, dots, video input included 10.4 inches color, dots, video input memory card included 10.4 inches color, dots 10.4 inches color, dots, memory card included 12.1 inches color, dots 12.1 inches color, dots, memory card included 12.1 inches color, dots, video input included 12.1 inches color, dots, video input memory card included 12.1 inches color, dots, memory card included System Composition Support tools following options available useing ZM-** series more effectively Item Model Specifications Applicable models ZM-82 ZM-72 ZM-52 ZM-43 ZM-42 protocol supported module connecting ZM-** Ethernet. Moreover, FL-net, correspondences ZW-80NU link protocol cyclic transmission message transmission (Word read/ write) supported. ZM-4EM Extension print circuit board extend memory display data back-up. capacity bytes FPROM. Network module Expansion memory Memory capacity bytes flash ZM-43EM memory, used extension screen data storage capacity. ZM-43SM Memory capacity bytes SRAM memory, used sampling data backup internal memory, ZM-80SM calendar setup. Used connection between ZM-** RS-422/485 terminal block. Used external module inputs outputs. Reads display data created personal computer, works external memory storage system memory manager data logging functions. Add-on connector with ports, specifically designed connector MITSUBISHI's programmer. Connects ZM-** personal computer, personal computer ZM-1REC printer. Connect ZM-** printer. Connect ZM-** barcode reader. Terminal converter Expansion module ZM-1TC ZM-322M Card recorder ZM-1REC Dual port interface ZM-1MD2 Data transfer cable Printer cable ZM-80C ZM-80PC Barcode reader connection ZM-80BC cable case connects multi-link used Cable Multi-link2 ZM-80MC connecting between ZM-** master master station station ZM-** slave station. ZM-42GS ZM-52GS ZM-72GS ZM-82GS ZM-71S ZM-71SE sheet which protects operation panel side. Protect sheet Screen edit software Japanese English Application software editing display data. System Composition ZM-71S, ZM-71SE Application software editing display data. ZM-71S Windows95/98/NT4.0 (Japanese) ZM-71SE Windows95/98/NT4.0 (English) ZM-80C (Data Transfer Cable) Connects ZM-** personal computer, personal computer ZM1REC. ZM-80PC (Printer Cable) Connects ZM-** printer. ZM-4EM, ZM-43EM (Expansion Memory) ZM-4EM ZM-52/72/82 ZM-43EM ZM-43 Extension print circuit board extend memory display data back-up. There 4Mbyte type (ZM-4EM,ZM-43EM) FPROM. ZM-43SM, ZM-80SM (Expansion Memory) ZM-43SM ZM-43 ZM-80SM ZM-52/72/82 Extension print circuit board back-up memory sampling data, ZM-** Internal Memory Memo Pad. There SRAM 512K byte type. also possible calendar displaying ZM-** this cassette. SANYO CR2430 CELL ZM-1REC (Card Recorder) Reads display data created personal computer, works external memory storage system memory manager data logging functions. ZM-1TC (Terminal Converter) Used connection between ZM-** RS-422/485 terminal block. System Composition ZM-1MD2 (ACPU/QCPU Dual Port Interface) Add-on connector with ports, specifically designed connector MITSUBISHI's ACPU/QCPU programmer. This improve operability ACPU/QCPU programmer that directly connected. ZM-80NU (Network Module) module making correspondence network Ethernet FLnet. possible connect more than sets ZM-**s same network, other equipments connected contributes price down whole system greatly. ZM-322M (Expansion module) Used external module inputs outputs. REC-MCARD (Memory Card) Used recording medium display data back-up memory manager data logging function. SRAM FLASH Card Type JEIDA Ver.4.0 later ZM-80BC (Cable Code Reader) Connects ZM-** code reader. ZM-80MC (Cable Multi-Link master station) cable which used connecting ZM-** master station ZM-** slave station Multi-Link connection. ZM-42GS/52GS/72GS/82G (Protection Sheet) ZM-42GS ZM-42/43 ZM-52GS ZM-52 ZM-72GS ZM-72 ZM-82GS ZM-82 Protects operation panel surface. Five sheets included package. Names Components Names Components Rear side ZM-42 series Front side ZM-42 series DC24V Front side ZM-43 series Rear side ZM-43 series 24VDC Mounting holes fixtures Display Function keys (Refer P1-51.) Power lamp power supply CN1: (RS-232C, RS-422) CN2: printer switches MJ1, data transfer bar-code reader ZM-1REC (option) ZM-2EM/4EM (option) Communication interface module (option) Names Components Front side ZM-52 series Rear side ZM-52 series DC24V Front side ZM-72 series Rear side ZM-72 series 100240VAC Front side ZM-82 series Rear side ZM-82 series 100240VAC Mounting holes fixtures Display Function keys (Refer P1-51.) Power lamp power supply power supply power supply CN1: (RS-232C, RS-422) CN2: printer switches MJ1, data transfer bar-code reader ZM-1REC (option) ZM-2EM/4EM (option) video (ZM-72TV/TVC/TSV/TSVC, ZM-82TV/ TVC) Communication Interface module (option) ZM-322M (option) Card interface (ZM-72TC/TVC/TSC/TSVC, ZM82TC/TVC) Dimensions Panel Cut-out Unit Dimensions Panel Cut-out Dimensions ZM-42 series View 173.6 Rear View Front View Side View 138.8 88.4 117.2 182.5 Panel cut-out ZM-42 series Unit +0.5 +0.5 130.8 Dimensions Panel Cut-out Dimensions ZM-43 series Unitmm Side view Front view 86.4 130.8 115.2 182.5 Rear view Bottom view remove this seal. unless optional unit mounted. 60mm (Note) Since connection positions serial connector differ when replaced used from ZM-42 series, inconvenient with attachment space. sure perform prior check attachment position. remove this seal. unless optional unit mounted. *60mm size with consideration attachment detachment after attachment. Since changes difference wiring system, electric wire size which wires that check real wiring Panel Cut-out ZM-43 series Unit 47.3 138.8 Dimensions Panel Cut-out Dimensions ZM-52D Unit View Rear View 60.1 Front View Side View Panel Cut-out ZM-52D Unit 220.5 +0.5 165.5 +0.5 Dimensions Panel Cut-out Dimensions ZM-72 series Unit View Rear View 100240VAC 76.3 Front View Side View Panel Cut-out ZM-72 series Unit +0.5 216.2 +0.5 215.2 Dimensions Panel Cut-out Dimensions ZM-82 series Unit View Rear View 100240VAC 79.8 Front View Side View Panel Cut-out ZM-82 series Unit +0.5 246.2 +0.5 245.2 Mounting Procedure Cut-out Mounting Procedure Mounting Procedure mounting panel (Max. thick: match dimensions shown below. case ZM-52D) +0.5 Mounting panel Unit +0.5 220.5 +0.5 +0.5 ZM-52D +0.5 ZM-72 Series ZM-82 Series (Note) Although panel size same, positions serial connector back face same. page 1-12. Insert fixtures attached ZM-** into mounting holes ZM-**. Tighten them with locking screws. Number fixtures: pcs. -Torque ZM-42/43/52 ZM-72/82 Fixture Dimensions Fixtures (Unit Mounting panel 10.5 Mounting hole Mounting hole 17.8 ZM-42/43 Series/ZM-52D ZM-** 10.5 17.8 ZM-72 Series/ZM-82 Series Mounting Angle module (ZM-**) shall installed within angle degrees shown below. 135° 135° Display 246.2 216.2 +0.5 +0.5 165.5 ZM-42 Series ZM-43 Series +0.5 +0.5 220.5 165.5 -+0.5 Wiring Wiring Electrical Wiring Connects cable power supply rear side ZM-**. DC24V Power supply DC24V±10% Earth ZM-42/43 Series, ZM-52D Type AC100-200V 100240VAC Power supply 100-200VAC Earth ZM-72 Series/ZM-82 Series Type Screw Screw Size Torque M3.5 M3.5 0.49 0.49 7.0MAX 8.0MAX Clamp Terminal (Unit 7.0MAX 8.0MAX ZM-42/43 Series, ZM-52D ZM-72 Series/ZM-82 Series When used wiring, refer value described above table. power source used must within allowable voltage fluctuation. power source with noise between cables ground cable. thick power cable possible minimize drop voltage. Keep cables 100V sufficiently away from high-voltage, large-current cables. Notes Usage ZM-72 series/ZM-82 series (100 specifications) Generally, isolating transformer improves noise resistance. However, display unit away from secondary port transformer noise gets mixed isolating transformer becomes unnecessary. power voltage fluctuation caused noise expected, recommended that voltage stabilizer used. Power Supply Insulation transformer Stabilized transformer ZM-72 Series/ ZM-82 Series 1.25mm2 twisted Wiring Grounding This equipment must earthed. independent earth pole shall used Control Terminal. (Earth construction class-3 grounding. level grounding resistance should less than cable which nominal cross section more than 2mm2 grounding. Grounding point shall near Control Terminal shorten distance grounding wires. When unit grounded along with other machines, grounded part building, adversely affected. input-output errors occur grounding, detach terminal from ground. ZM-** Other equipment Class-3 grounding Wiring communication Never place communication cable with electric circuits. Never bundle these cables together with other wires ducts electric boxes using cord locks. Although tempting bundle cables neatly together, this does necessarily lead noiseresistant configuration. recommended that communication cable independently wired. Wiring duct Communication cable Communication cable Power cable control cable Power cable control cable Cord lock Specifications Item Power Supply Specifications General Specifications Type Rated Voltage Permissible Range Voltage Permissible Momentary Power Failure ZM-42 series ZM-43 series 24VDC ZM-52D 10ms less less less 1.5ms Demand Rushed Electric Current With-stand voltage Insulation Resistance Physical Environment 500V more Ambient Temperature Storage Ambient Temperature Ambient Humidity Dust Solvent Resistance Corrosive Vibration Resistance ~+50 ~+60 less (without condensation) conductive dust cutting organic solvent cling unit corrosive Vibration frequency: 10~150Hz, Acceleration: 9.8m/s (1.0G) directions hour Mechanical Working Conditions Shock Resistance Pulse shape: Sine half wave, Peak acceleration: 147m/s2 (15G), directions times Electrical Working Conditions Noise Resistance Static Electricity Discharge Resistance Noise voltage: 1500Vp-p, noise width: Front panel: Class-3 grounding Protection structure: front panel complies with IP65 (when using gasket) rear panel complies with IP20 Form: body Mounting procedure: inserted mounting panel Cooling naturally Approx. 0.8kg 182.5 138.8 +0.5 Grounding Mounting Conditions Structure Cooling System Weight Dimensions (mm) Panel Cut-out (mm) Case Color Material Approx. 0.8kg 182.5 X138.8 57.3 +0.5 +0.5 BLACK*3 PC/PS Approx. 1.1kg 66.1 220.5-0 165.5 GREY PC/ABS +0.5 +0.5 +0.5 GREY PC/ABS only specifications power supply including 4mm, size boss communication module Specifications Type Item Rated Voltage Permissible Range Power Supply ZM-72 series 240V 20ms less less 20A: 30A: ZM-82 series 240V 20ms less less 20A: 30A: Voltage Permissible Momentary Power Failure Demand Rushed Electric Current With-stand voltage Insulation Resistance Between external terminals 1500V min. 500V more ~+50 (ZM-72D/DC: ~+60 ~+40 Physical Environment Ambient Temperature Storage Ambient Temperature Ambient Humidity Dust Solvent Resistance Corrosive Vibration Resistance less (without condensation) conductive dust cutting organic solvent cling unit corrosive Vibration frequency: 10~150Hz, Acceleration: 9.8m/s (1.0G) directions hour Mechanical Working Conditions Shock Resistance Pulse shape: Sine half wave, Peak acceleration: 147m/s2 (15G), directions times Electrical Working Conditions Noise Resistance Static Electricity Discharge Resistance Noise voltage: 1500Vp-p, noise width: Front panel: Class-3 grounding Protection structure: front panel complies with IP65 (when using gasket) rear panel complies with IP20 Form: body Mounting procedure: inserted mounting panel Cooling naturally Approx. 2.5kg 92.3 216.2 +0.5 +0.5 Grounding Mounting Conditions Structure Cooling System Weight Dimensions (mm) Panel Cut-out (mm) Case Color Material Approx. 3.0kg 95.8 +0.5 246.2 GREY PC/ABS +0.5 Specifications Display Specifications Item Type ZM-42L ZM-42D ZM-43L ZM-43D ZM-43T ZM-52D moSTN moDisplay Device nochrome color nochrome color color color Resolution (dots) Pitch (mm) Effective Display Area (mm) Color 0.36 0.36 0.12 0.36 0.36 0.36 0.12 0.36 0.36 0.36 0.082 0.246 115.2 86.4 (5.7 inches) Monochrome Monochrome colors gradation gradation blinking blinking blinking colors blinking 157.4 118.1 (7.7 inches) colors blinking colors Back-light Contrast Adjustment Back-light Average Life Power Lamp Cold cathode rectifier function switches (only case color type) Approx. Approx. 25,000H Approx. 50,000H 25,000H lamp when power supplied. Item Display Device Type ZM-72D series ZM-72T series ZM-72TS series color 0.11 0.33 0.33 0.33 211.2 158.4 (10.4 inches) colors blinking colors Cold cathode rectifier 0.264 0.264 color ZM-82T series color Resolution (dots) Pitch (mm) Effective Display Area (mm) Color 0.3075 0.3075 246.0 184.5 (12.1 inches) Back-light Contrast Adjustment function switches (only case color type) Approx. 25,000H lamp when power supplied. Back-light Average Life Approx. 10,000H Power Lamp When normal temperature 25°C, surface illuminance display default. Specifications Display Function Specifications Item Display Language Characters Japanese Eng./W. Europe ASCII code ASCII code ASCII code Specifications Chinese Chinese (simplified) Korean 1/4-size, 1-byte code 2-byte (16-dot) 2-byte (32-dot) ASCII code ASCII code ASCII code Chinese Chinese (simplified) Hangul (without Kanji) Size Characters 1/4-size dots 1-byte dots 2-byte dots dots Enlarge Resolution 1/4-size 1-byte 2-byte columns lines columns lines columns lines columns lines columns lines columns lines columns lines columns lines columns lines Number Characters Property Characters Display property normal, reverse, blinking, bold, shadow Color colors blinking colors colors+ blinking /monochrome graduation+blinking Foreign characters registration Kind Drawing Only Japanese characters possible Full size dot, when font possible: Full size dot, Lines line, continuous lines, box, parallelogram, polygon Circles circle, arc, sector, ellipse, elliptical arc, elliptical sector Others tile patterns Type lines types (fine, thick, dot, chain, broken, two-dot chain) Tile patterns types (incl. user-definable types) Display property normal, reverse, blinking Color colors blinking colors colors+ blinking /monochrome graduation+blinking Property Drawing Color specification foreground, background, boundaries (line) Specifications Function Performance Specifications (All ZM-** series) Item Screens Screen Memory Switches Switch operation mode Max. 1024 FP-ROM (flash ROM), Appox. 2,816K bytes*1(different from language) screen (192 screen ZM-42/43 Series) Set, reset, momentary, alternate, light (possible press function switch display switch same time) [Matrix type switches display pressed same time] Specifications Lamps Reverse, blinking, exchange graphics screen (192 screen ZM-42/43 Series) Pie, bar, panel meter closed area graph displayed without limit. Total capacity screen: within 128KB Statics trend graphs: Max. layer*2 Graphs Numerical Data Display limits, total capacity screen: within limits, total capacity screen: within Resolution 240, Max. characters 480, Max. characters 600, Max. characters limits, total capacity screen: within Data Setting Character Display Message Display Messages Sampling 6144 lines Sampling display buffer data (constant sample, synchronize, sample, relay sample, alarm function) Multi-Overlaps Data Blocks Graphic Libraries Patterns Macro Blocks Page Blocks Direct Blocks Screen Blocks Max. 1024 Max. 1024 Max. 2560 Max. Max. 1024 Max. 1024 Max. 1024 Max. 1024 Temperature Control Network Table Max. Calendar Hard-Copy Buzzer Self-diagnostic Function Provided Provided Provided, types (intermittent short long sounds) Self-test function switches Check function communication parameter setting Check function communication hardware version following version, ZM42/43 used, screen memory approx. 760K bytes. ZM82T Series A~E, ZM-72TS Series A~E, ZM-72T Series A~F, ZM-72D Series A~E, ZM-52D Series Layer screen (base overlaps) Specifications Touch Panel Specifications Item Switch Resolution Form Life Touch Panel Specifications Analog, 1024(W) 1024(H) Resistance film form million times more Function Switch Specifications Item Number Switches Type Switch Life Switch ZM-42/43) Pressure sensitive switches million times more Specifications Interface Specifications Item Serial Interface connecting (D-sub pins, female) RS-232C, RS-422/485 Asynchronous type Data length: bits Parity: even, odd, none Stop bit: bits Baud rate: 2400, 4800, 9600, 19200, 38400, 57600, 115200bps (115200bps invalid ZM-42/43) Serial Interface transferring data /connecting bar-code reader /connecting card recorder (modular jack, pins) Printer Interface RS-232C, RS-422/485 case connecting card recorder (option) slot SRAM/FROM: Max. byte which complies with JEIDA Ver. (with some limits) Complies with centronics, half pitch pins (for PC98) NEC: PR201, EPSON: compatibles with ESC/P-J84, ESC/P super function, ESC/P24-J84 CBM292/293 printer (The screen copy cannot printed out.) Specifications Drawing Environment Item Drawing Method Drawing Tool Exclusive drawing software Name exclusive drawing software ZM-71S (Japanese), ZM-71SE (English) Personal computer with i486 more (Pentium more recommended) Microsoft Windows 95/98 version Memory minimum 40MB memory operate Display resolution more (800 recommended) Specifications Specifications Compatible connection Maker Sharp Model J-board, JW10, JW20/20H, JW30H W70H/100H, JW50/70/100, JW50H/70H/100H MITSUBISHI Series/Q Series link module/CPU port, FX1/2 Series OMRON HITACHI Matsushita YOKOGAWA YASUKAWA TOYOPUC FUJI Koyo Allen-Bradley Fanuc TOSHIBA SIEMENS Shinko SAMSUNG KEYENCE FANUC Series, Series, Series HIDEC H300/700/2000, Series FA500, FA-M3 GL40/60/70 PC2/2J, F70/80H/120H, NS/NJ, FLEX-PC CPU/COM SU-5/6, SG-8 PLC-5, SLC500 Series 90-30 EX100/2000, Series T1500/505 SELMART Series Series Series K10/60/200, K500/K1000 Power Mate-Model They match protocol described above, does necessary mean guarantee operation each such noise level. Serial Connector (CN1) 100240VAC Serial Connector (CN1) used communicating between ZM-** (RS-232C, RS-422/485). Serial Connector (CN1) arrangement serial connector follows: CN1Dsub 25pin Signal Contents Frame ground RS-232C send data RS-232C receive data RS-232C request send RS-232C clear send used Signal ground used used used used -RTS -CTS +CTS +RTS RS-422 send data RS-422 send data RS-422 send data used used RS-422 send data RS-422 receive data RS-422 receive data used used used used RS-422 receive data RS-422 receive data Communication cable RS-232C/RS-422 RS-232C case RS-232C, form pair. Connect shielded cable connector case cover. ZM-** (CN1) Signal Shielded cable RS-232C port link module Receive data Send data Serial Connector (CN1) RS-422 case RS-422, -SD, form pair. possible. Connect shielded cable connector case cover. Terminal converter ZM-1TC which optional equipment case using terminal blocks RS422/485 connection. Specify terminal resistance switches ZM-**. (Refer next page.) ZM-** (CN1) Signal Send data Send data Receive data Receive data Shielded cable RS-422 port link module Terminal Blocks RS-422/485 When connecting terminal block, mount terminal converter ZM-1TC (sold separately) serial connector (CN1). RS-422 signal wiring ZM-1TC connected serial connector (CN1). 100240VAC ZM-1TC (set top: 4-wire connection) Signal ZM-1TC (Terminal Converter) RDSD+ SDSG Specify 4-wire connection 2-wire connection switch ZM-1TC (SW1). (set top: 4-wire connection) Setting Switches Setting Switches Setting Switches (DIPSW) Memory Extension (invalid ZM-42) terminal resistance used terminal resistance Terminal resistance MJ1(modular jack Setting Terminal Resistance DIPSW case connecting ZM-** 4-wire connection RS-422/485. DIPSW case connecting ZM-** 2-wire connection RS-422/485. DIPSW case connecting card recorder (option) Modular jack terminal resistance Modular jack always Setting Memory Extension (This switch invalid ZM-42. Keep DIPSW OFF.) DIPSW case selecting "Memory Extension (Refer page 1-61, 1-62) Keep DIPSW (not used) OFF. Modular Jack Modular Jack MJ1/2 Signal +SD/RD -SD/RD Modular Jack (MJ1/2) right diagram arrangement signal name modular jack 12345678 External power supply Max. 150mA Setting Modular Jack (MJ1/MJ2) Specify MJ1/MJ2 screen edit software ZM-71SE. Select [System Setting] from [Item], click [Others]. [Others] dialog displayed. setting items [Modular Jack [Modular Jack [P2] menu follows. Modular Jack Modular Jack [Editor port] [Not used] [Memory Card] [Memory Card] [Barcode] [Barcode] [V-I/O] [V-I/O] [Multi-Link]*1 [Multi-Link]*1 [Temp. CTRL Net]*2 [Temp. CTRL Net]*2 [ZM-Link]*2 [ZM-Link]*2 [Touch Switch]*3 [Touch Switch]*3 impossible select both [Multi-Link] [Temp. CTRL Net] each setting modular jack. possible select this item when [Multi-Link selected [Connection] [Local Port] [Comm. Parameter] dialog. [Multi Link (master)] [Temperature Control Network] [ZM-Link] available following hardware version later ZM-**. ZM-42/43 series, version used. Analog type ZM-82T: ZM-72TS ZM-72T ZM-72D ZM-52D Matrix type version [Touch Switch], refer "Analog Input" manual. Screen edit software transferring modular jack (MJ1) case editor transferring. When [Editor port] selected [Modular Jack [P2] menu, also possible transfer data while running, because auto change local mode mode valid. When [Editor port] selected, on-line editing simulation mode also available. When item other than [Editor port] selected [Modular Jack [P2] menu, sure transfer data software local mode. On-line editing simulation mode available. When data transferred software, cable data transferring which optional equipment made Sharp Corporation. (ZM-80C: option) connect ZM-** personal computer. Code Reader Interface Code Reader Interface possible receive signal from code reader connecting code reader ZM-** modular jack (MJ1/MJ2) ZM-** series. connect code reader ZM-** MJ1/MJ2, cable Code Connecting Cable ZM-80BC which optional equipment made only demand. Length Accessory Modular Plug 12345678 Brown Orange Yellow Notes Connection case using code reader which uses control, code reader work normally without jumping CTS. output power supply (+5V) max. 150mA. (Refer preview page.) When code reader connected ZM-41/70 Series used, connect ZM-** following cable. 12345678 Barcode Reader D-sub 9pin Signal Signal Orange Yellow Jump pins, 1(CTS) 4(RTS). Brown Printer Interface (CN2) Printer Interface (CN2) When printer connected ZM-** connector (CN2), possible hard-copy screen display ZM-**, data sheet, sampling data. connection printer ZM-**, apply printer cable ZM-80PC (sold separately) which matches 36-pin parallel interface. 100240VAC Printer Half pitch pins Centronics Printer ZM-42 Series Compatible Printer Models PC-PR201 series EPSON Compatibles with ESC/P24-J84, ESC/P-J84, ESC/P super function HP(HEWLETT PACKARD) Level Video Interface Video Interface When video camera connected optional ZM-** which video interface, image which taken video camera displayed directly screen ZM-** series (only case ZM-72TV/TVC, ZM-72TSV/TSVC, ZM-82TV/TVC). Video Interface ZM-** 100240VAC Video Display Specifications Display Color 262,143 colors Input Channel Channels Signal Form NTSC type, type Display Size 480, 240, dots (possible change size) Color Adjustment contrast (256 steps), brightness (256 steps), color gain (256 steps) display size ZM-72TV/TVC, able other switches such panel. (please apply dot) Connection Connection 15-1 Connection with Sharp Link Communication ZM-** connected. ZM-** RS-232C RS-422(RS-485) Link Communication (Multi-drop) ZM-*2 multiple PLCs connected. ZM-** RS-485 Maximum length 500m stop PLC1 PLC2 PLC3 PLCn Available multi-link communication Manufacturer SHARP MITSUBISHI OMRON HITACHI MATSUSHITA YOKOGAWA YASKAWA TOYOPUC FUJI Koyo Allen-Bradley Fanuc TOSHIBA SEIMENS Kamigo SAMSUNG KEYENCE FATEK IDEC TAIAN Models series, JW70/100 port, JW20/30 port An/A/N/U series, series, Net10, series protocol) SYSMAC series, series, CQM1 series, HIDIC-H MEWNET FA500, FA-M3 Memobus TOYOPUC MICREX-F, FLEX-PC, computer link SU/SG, SR-T PLC-5, SLC500, Micro Logix 1000 series series S7-200 SELMART series, plus, SECNET series, series MASTER-K500 K1000 FACON series MICRO TP02 General purpose serial Connection Multi-drop Communication (RS-485) Refer manual each manufacturer connection. <E.g.> following example describes ZM-** connected three PLCs made MITSUBISHI. MITSUBISHI's manual further details. ZM-** (CN1) Signal Link module Signal Link module Signal Link module Signal SD/RD terminal resistance (ON) twist shielded cable. Link Communication (Multi-link Multi-link units connected PLC. Between ZM-** master station same those communication. Communication between ZM-** RS-485 (2-wire system) Maximum length: terminal ZM-** slave (Local Port ZM-** slave (Local Port ZM-** master (Local Port ZM-** slave (Local Port Available PLCs multi-link January 2001, PLCs supported follows. PLCs which usable communication will supported. driver, Multi-Link supported version 1.100 later ZM-** master station, make sure hardware version unit follows. ZM-42/43 series, version used. ZM-82T series: ZM-82D series: ZM-72TS series:D, ZM-72T series: ZM-72D series: ZM-52D series: Multi-Link cannot used with Network module ZM-80NU. Connection <Type> MITSUBISHI AnA/N/U series MITSUBISHI series MITSUBISHI ACPU Port MITSUBISHI series MITSUBISHI QnACPU Port MITSUBISHI QnHCPU Port MITSUBISHI QnHCPU Port MITSUBISHI series(A prt) MITSUBISHI FX2N series MITSUBISHI FX1S series OMRON SYSMAC OMRON SYSMAC OMRON SYSMAC SHARP series SHARP JW100/70H Port SHARP JW20 Port HITACHI HIDIC-H HITACHI HIDIC-S10/2 alpha HITACHI HIDIC-S10/ABS MATSUSHITA MEWNET YOKOGAWA FA500 YOKOGAWA FA-M3 YOKOGAWA FA-M3R YASKAWA Memobus YASKAWA CP9200SH/MP900 TOYOPUC FUJI MICREX-F series FUJI MICREX-F series ZM70 FUJI FLEX-PC series FUJI FLEX-PC FUJI FLEX-PC FUJI FLEX-PC(T) FUJI FLEX-PC CPU(T) FUJI MICREX-F link ZM70 <Calendar> Provided Provided Provided Depends model Provided Provided Provided Provided Depends model Provided Depends model Provided Provided Provided Provided Provided Provided provided provided Depends model Provided Provided Provided Depends model provided Provided Provided Provided Provided Provided Provided Provided Provided Provided <Type> <Calendar> KOYO SU/SG Depends model KOYO SR-T Provided KOYO SR-T(K prt) provided PLC-5 provided SLC500 Provided Micro Logix 1000 provided Fanuc series provided Fanuc series(SNP-X) provided TOSHIBA series Provided SIEMENS S5/S7 provided SIEMENS S5/S7 ZM70 provided SIEMENS TI500/505 Provided SIEMENS port provided SAMSUNG series provided SAMSUNG SECNET Depends model KEYENCE series provided KEYENCE KZ-A500 Port Provided KEYENCE series provided KEYENCE KZ24/300 series provided KEYENCE KV10/24 series provided MASTER-K10/60/200 provided MASTER-K500/1000 provided LGMKX00S provided FANUC Power Mate provided FATEK AUTOMATION: FACON series Provided IDEC MICRO3 Provided MODICON Modbus Depends model YAMATAKE series Provided TAIAN TP02 Provided Example wiring between ZM-** terminal converter (ZM-1TC), optional equipment made Sharp Corporation. Multi-link instruction manual further details. Wire shielded only both sides that they connected. When ZM-1TC terminal converter used. switch (SW1) ZM-1TC 2-wire connection. ZM-** master MJ1/2 Terminal block prepared user Signal ZM-** slave CN1+TC485 Signal ZM-** slave CN1+TC485 Signal Terminal resistor (OFF) ZM-** slave CN1+TC485 Signal Terminal resistor (ON) Terminal resistor (OFF) Terminal resistor (ON) When ZM-1TC terminal converter used. Short-circuit between +SD, -SD. Connection Multi-link Multiple ZM-** connected. (n=1 ZM-** ZM-** ZM-** ZM-** connections shown below recommended. RS-485 Maximum length 500m Available PLCs multi-link When multiple ZM-** connected link module Manufacturer SHARP MITSUBISHI MITSUBISHI OMRON HITACHI MATSUSHITA YOKOGAWA YASKAWA TOYOPUC FUJI TOSHIBA SIEMENS SHINKO SAMSUNG Models series(JW-10CM, JW-21CM, Z-331J/332J, ZW-10CM) AnN, AnA, series, Net10, series prt) port (with ZM-1MD2) SYSMAC series, series HIDIC-H MEWNET FA-M3 Memobus TOYOPUC MICREX-F, computer link series S7-200 SELMART series, pius, SECNET MASTER-K500 K1000 case Sharp Corporation, only link module correspondences multi-link connection. (The communication port etc. does correspond.) Connection terminal converter (ZM-1TC), optional equipment made Sharp Corporation RS-485 connection. When ZM-1TC terminal converter used. switch (SW1) ZM-1TC 2-wire connection. ZM-**+ZM-1TC Signal terminal resistance (ON) ZM-**+ZM-1TC Signal RD/SD terminal resistance (ON) ZM-**+ZM-1TC Signal RD/SD terminal resistance (ON) Link module Signal +RxD -RxD +TxD -TxD twist shielded cable. When ZM-1TC terminal converter used. Short-circuit between +SD, -SD. When multiple ZM-** connected directly MITSUBISHI's QCPU port optional equipment, ZM-1MD2 required. Also, optional cable, MB-CPUQT which connect ZM-1TC ZM-** side ZM-1MD2 QCPU port side, recommended. When ZM-1TC terminal converter used. switch (SW1) ZM-1TC 2-wire connection. ZM-**+ZM-1TC Signal terminal resistance (ON) ZM-**+ZM-1TC Signal RD/SD terminal resistance (ON) twist shielded cable. ZM-**+ZM-1TC Signal RD/SD terminal resistance (ON) ZM-1MD2 ZM-Port Signal +RxD +TxD +DSR +DTR -RxD -TxD -DSR MB-CPUQT When ZM-1TC terminal converter used. Short-circuit between +SD, -SD. Connection 15-2 Connection Ethernet/FL-net When network module ZM-80NU mounted ZM-43/52/72/82 series, connectable with Ethernet/FL-net ZM-42 series connectable.) addition, program version 1.2.0.0 later ZM-43/52/72/82 series, version 1.2.0.0 later ZM-71SE corresponds Ethernet/FL-net. case Ethernet (Personal computer) ZM-71SE Ethernet RS-232C/RS-485 applicable Ethernet applicable Ethernet corresponds Ethernet Sharp JW20H/30H [Ethernet module JW-255CM (10BASE5)] JW50H/70H/100H [Ethernet module JW-51CM (10BASE5/10BASE-T)] Mitsubishi series/Q series Yokogawa FA-M3 case FL-net FL-net applicable FL-net corresponds Ethernet Sharp JW20H/30H [FL-net module JW-20FL5 (10BASE5)/JW-20FLT (10BASE-T)] JW50H/70H/100H [FL-net module JW-50FL (10BASE5/10BASE-T)] J-board [FL-net board Z-336J (10BASE5/10BASE-T) FL-net correspondence model each company Connection 15-3 Connection general purpose serial communication ZM-** connected with general purpose computer using user program (exclusive command use). Refer (general purpose serial) user's manual detail. When computer ZM-** RS-232C less than 15m, RS-422 (485) transmision distance less than 500m. Interruption processing used. (Switch ON/OFF, write-in ten-key, screen change) General purpose computer connection RS-232C RS-422 When computer ZM-** ZM-** sets connectable.) command point needs station number specified. Interruption processing cannot used.(Switch ON/OFF, write-in ten-key, screen change) General purpose computer connection RS-422 Operation ZM-** Main Menu Operation ZM-** Main Menu When power ZM-** turned first time, screen below left displayed. After transferring screen data ZM-**, following "Main Menu" displayed. When power turned first time: "Main Menu" after trasferring data Main Menu System Information ZM-72T FONT VER.1.000/1.000/1.000 JAPANESE 1998- VER. 1.000 SYSTEM PROG. VER.1.000 Screen Data Information Size 786432 Type: Comment: Error: Stop Time-Out: 0.50 Retry: Connection: Signal Level: RS232C Stat.No.: Baud Rate: 19200 Data Length: Stop Bit: Parity: Even Send Delay: 0msec Editor Memory-Card Test screen data been already transferred ZM-**, press [SYSTEM] switch, then press [F1] switch. [Main Menu] displayed. "Main Menu" displayed. [SYSTEM] switch [F1] switch Main Menu System Information ZM-72T FONT VER.1.000/1.000/1.000 JAPANESE 1998- VER. 1.000 SYSTEM PROG. VER.1.000 Screen Data Information Size 786432 Type: Comment: Error: Stop Time-Out: 0.50 Retry: Connection: Signal Level: RS232C Stat.No.: Baud Rate: 19200 Data Length: Stop Bit: Parity: Even Send Delay: 0msec Editor Memory-Card Test Main Menu "Main Menu" system menu transferring data between personal computer ZM-**. When screen data transferred from personal computer ZM-**, "Main Menu" must displayed. [Editor port] selected [Modular Jack [P2] menu editing software on-line editing executed, necessary display "Main Menu". Operation ZM-** Main Menu System program version Model name ZM-** Font data version Data size Main Menu System Information SYSTEM PROG. VER.1.000 ZM-72T FONT VER.1.000/1.000/1.000 JAPANESE 1998- VER. 1.000 Screen Data Information Size 786432 Type: Comment: type comment specified panel editor Error: Stop Time-Out: 0.50 Retry: Connection: Signal Level: RS232C Stat.No.: Baud Rate: 19200 Data Length: Stop Bit: Parity: Even Send Delay: 0msec driver version name Multi-Link Network Multi-Link Network Stat.No.: Total: Retry: Multi-link setting This menu displayed only case selecting [1:1] [Connection] [Comm. Parameter]. Editor Memory-Card Setting comm. parameter Test Setting modular jack "Main Menu" ZM-42/43 Model name ZM-42/43 System program version Main Menu PROG. VER. 0.591 ZM-42D 1998- 12:24:30 Test FONT VER.1.000/1.010/1.000 JAPANESE VER.1.000 Memory -Card Font data version type comment specified panel editor Communication Parameter driver version name Type Comment: Editor:MJ1 Setting modular jack case ZM-42/43, when "Communication Parameter" switch "Main Menu" pressed, following "Comm. Param." displayed. 12:24:30 Test Memory -Card Comm. Param. Screen Data Size Multi-Link Network Stat.No. Total Retry Connection Signal Level Stat. No.: Baud Rate Data Length Stop Parity Send Delay Main Menu 786432 Communication Parameter Error Stop Time-out 0.50 Retry Press "Communication Parameter" switch. Multi-Link RS232C 19200 Even msec Multi-link setting This menu displayed only case selecting [Connection] [Comm. Parameter]. Editor:MJ1 Operation ZM-** Main Menu Test When switch "Main Menu" pressed, following "I/O Test" displayed. This test menu check only ZM-** hardware. Memory-Card Test Press [I/O Test] switch. Test Main Menu Printer Check Switch Check Self-Loop Test Please refer manual, "Hardware Specifications". Communication Port RS-232C RS-485 Self-Loop Test case ZM-42/43, when switch "Main Menu" pressed, following "I/O Test" displayed. Then, "Serial Test" switch "I/O Test" pressed. following "Serial Test" displayed. self-loop test executed this screen. 12:24:30 Test Memory -Card Press "I/O Test" switch. Communication Parameter Press "Serial Test" switch. Test Main Menu Serial Test Self-Loop Test Test Please refer manual, "Hardware Specifications". Communication Port Printer Check RS232C RS485 Serial Test Switch Check Self-Loop Test Operation ZM-** Main Menu Self-loop Test This test menu check signals necessary ZM-** communicate with personal computer using only ZM-**. Signal Test RS-232C Select [CN1] [RS-232C] [Communication Port] pressing each switch. Communication Port RS-232C RS-485 Loop-back Test Check signals, [SD] [RD]. Jump pins, CN1. test [OK] lamp turns when [Self-Loop Test] switch pressed. Self-Loop Test Self-Loop Test Test CTS/RTS Check signals, [CTS] [RTS]. Jump pins, 4(RTS) 5(CTS) CN1. test [CTS] lamp [RTS] lamp turn same time that [RTS] switch pressed. Similarly, test [CTS] turns same time that [RTS] turned OFF. Self-Loop Test Self-Loop Test Self-Loop Test Self-Loop Test Operation ZM-** Main Menu Signal Test RS-485 Select [CN1] [RS-485] [Communication Port] pressing each switch. Communication Port RS-232C RS-485 Loop-back Test Check signals, [SD] [RD]. Jump each pin, CN1. test [OK] lamp turns when [Self-Loop Test] switch pressed. Self-Loop Test Self-Loop Test Test CTS/RTS Check signals, [CTS] [RTS]. Jump each pin, 14(+RTS) 19(+CTS), 17(-RTS) 18(-CTS) CN1. test [CTS] lamp [RTS] lamp turn same time that [RTS] switch pressed. Similarly, test [CTS] turns same time that [RTS] turned OFF. Self-Loop Test Self-Loop Test Self-Loop Test Self-Loop Test Operation ZM-** Main Menu Signal Test RS-232C Select [MJ1] [MJ2]) [RS-232C] [Communication Port] pressing each switch. Communication Port RS-232C RS-485 Loop-back Test Check signals, [SD] [RD]. Execute test connecting data transfer cable (ZM-80C) CN1. adaptor, ADP25-9, which attached ZM-80C, ZM-80C. connect modular jack side ZM-80C MJ2), ADP25-9 side ZM-80C CN1. ZM-80C MJ1/2 test [OK] lamp turns when [Self-Loop Test] switch pressed. Self-Loop Test Self-Loop Test Operation ZM-** Main Menu Printer Check Check signal printer. test test printout executed satisfactorily when connecting ZM-** printer pressing this [Printer Check] switch. [Example] Switch Check Check reaction touch switches ZM-** panel. When [Switch Check] switch pressed, following screen displayed. switch check screen displayed. Main Menu Check Switch Check Retu Eras Press [Switch Check] switch. Confirm that color pressed area changes into white. white color means that switch reacts touch normally. Pressing [F4] switch leads previous [I/O Test] screen. Pressing [F5] switch deletes white dots. Retu Eras Operation ZM-** Main Menu Test SYSTEM Function Switches Check eight switches (six switches ZM-42/43) placed vertically right side ZM-** panel. test lamps screen turn when each switch pressed. Press [F4] switch. test when [F-4] lamp lit. Main Menu Pressing this [Main Menu] switch leads previous [Main Menu]. "Main Menu" displayed. Main Menu Main Menu System Information ZM-72T FONT VER.1.000/1.000/1.000 JAPANESE 1998- VER. 1.000 SYSTEM PROG. VER.1.000 Check Switch Check Screen Data Information Size 786432 Type: Comment: Error: Stop Time-Out: 0.50 Retry: Connection: Signal Level: RS232C Stat.No.: Baud Rate: 19200 Data Length: Stop Bit: Parity: Even Send Delay: 0msec Multi-Link Network Multi-Link Network Press [Main Menu] switch. Stat.No.: Total: Retry: Editor Memory-Card Test Operation ZM-** Main Menu Memory-Card When [Memory-Card] switch "Main Menu" pressed, following "Memory-Card" displayed. This screen transfer screen data between ZM-** memory-card. Memory-Card Test "Memory-Card" screen displayed. Press [Memory-Card] switch. Memory-Card Main Menu Port Selection Modular Jack Memory-Card Socket Transfer Display Card Display Card Display Card Start Cancel "Memory-Card" ZM-42/43 Memory-Card Port Selection Modular Jack Main Menu Data Selection Screen Data Font Data Transfer Display Card Display Card Display Card Start Cancel Data Selection Screen Data Driver Font Data Program Driver Program Procedure Data Transferring Port Selection Select [Modular Jack MJ1] switch [Modular Jack MJ2]) case using modular jack. Select [Memory-Card Socket] switch case using memory-card interface. When each switch pressed, "Memory-Card Information" window displayed. case ZM-42/43, pressing "Close" switch leads original screen after checking memory card information. Memory-Card Memory-Card Main Menu Close Port Selection Modular Jack Memory-Card Socket Memory-Card Information Port Selection Transfer Display Card Display Card Display Card Start Cancel Program Modular Jack Memory-Card Version:-.-MJ1 Socket Font Data Version:-.-/-.-/-.-I/F Driver Version:-.-Screen Type: Screen Comment: Data Selection Screen Data Font Data Driver Program case selecting [Memory Card] from [Modular Jack [Others] dialog ZM-71SE, possible select [Modular Jack switch [Port Selection] menu [Memory-Card] screen ZM-**. Operation ZM-** Main Menu Data Selection, Transfer Pressing each switch leads selection target data transferring. (Possible select multiple items.) Data Selection Memory-Card Main Menu Close Transfer Memory-Card Main Menu Close Memory-Card Information Port Selection Transfer Display Card Display Card Display Card Start Cancel Memory-Card Information Port Selection Transfer Display Card Display Card Display Card Start Cancel Program Modular Jack Memory-Card Version:-.-MJ1 Socket Font Data Version:-.-/-.-/-.-I/F Driver Version:-.-Screen Type: Screen Comment: Program Modular Jack Memory-Card Version:-.-MJ1 Socket Font Data Version:-.-/-.-/-.-I/F Driver Version:-.-Screen Type: Screen Comment: Data Selection Screen Data Font Data Data Selection Screen Data Font Data Driver Program Driver Program Start When [Start] switch pressed, data transferring starts. During data transfer, character, `Start', switch changes into character, `Busy', switch starts blinking. After transferring data, following message displayed. Press [OK] switch. case ZM-42/43, "start" switch will blinking data transfer starts. Start transferring Memory-Card Main Menu Close During transferring Memory-Card Main Menu Close Memory-Card Information Port Selection Transfer Display Card Display Card Display Card Start Cancel Memory-Card Information Port Selection Transfer Display Card Display Card Display Card Busy Cancel Program Modular Jack Memory-Card Version:-.-MJ1 Socket Font Data Version:-.-/-.-/-.-I/F Driver Version:-.-Screen Type: Screen Comment: Program Modular Jack Memory-Card Version:-.-MJ1 Socket Font Data Version:-.-/-.-/-.-I/F Driver Version:-.-Screen Type: Screen Comment: Data Selection Screen Data Font Data Data Selection Screen Data Font Data Driver Program Driver Program Finish transferring Memory-Card Main Menu Close Memory-Card Information Port Selection Transfer Display Card Display Card Display Card Start Cancel Program Modular Jack Memory-Card Version:-.-MJ1 Socket Font Data Version:-.-/-.-/-.-I/F Driver Version:-.-Screen Type: Screen Comment: Data Selection Work nomally finished. Screen Data Font Data Program Driver When transfer data from ZM-** memorycard card interface(= [Memory-Card Socket]) ZM-**, SRAM type memory card. FROM type memory card used. Operation ZM-** Main Menu Message Display Data Transferring error occurs during transferring data, message display window shown right displayed. kinds contents messages shown below. Work nomally finished. Message Work normally finished. ZM-1REC connecting ZM-1REC Communication Error Memory-Card setting Contents specified operation been concluded normally. ZM-1REC connecting when selecting modular jack. communication error occurred between ZM-** ZM-1REC when selecting modular jack. memory card inserted. case trying write data into memory card when inserting FROM type memory card) Cannot write data into memory card because data size ZM-** larger than capacity memory card. Cannot write data into memory card because write protect switch memory card error occurred while writing data into memory card. data reading target does exist. specified type data ZM-** different from type memory card data. data memory card cannot read. error occurred during writing data into flash ZM-**. There some discrepancy data, when comparing data between memory card ZM-**. This message appears inform user that data ZM-** will broken transferring font data (the size which larger than present data) from memory card ZM-**. (The [OK] switch continues transferring. [Cancel] switch stops transferring.) error occurred some cause other than above mentioned. Memory-Card Capacity over Write Protect Writing Error occurred. Selected data does exist. ZM-** type different. Selected data read. Reading Error occurred. Data discrepant Screen data ZM-** will broken. Undefined Error occurred. Function Switches Type Function Switches [SYS], [F1], [F2], [F3], [F4], [F5], [F6], [F7] (ZM-42/43 [SYS], [F1] [F5]) [SYS] switch pressing this switch, functions switches [F1] [F7] defined. type [SYS] switch alternate. When this switch pressed once, switch menu displayed side function switches [F1] [F5], each function switch corresponds item displayed switch menu. When [SYS] switch pressed again, switch menu which displayed screen will disappear, functions switches [F1] [F7] defined purpose user. data these function switches allocated memory area Function [F1] [F5] when switch menu displayed [F1] Mode This switch changes operation mode. Main Menu Mode Mode Mode Main Menu Mode (possible specify changing time) [F2] Contrast Adjustment (dark) invalid case color type This switch adjusts contrast LCD. When [F2] switch pressed once, color becomes dark. this switch held down second, color changes rapidly into darkness. [F3] Contrast Adjustment (intermediate) invalid case color type This switch also adjusts contrast LCD. When [F3] switch pressed once, color becomes intermediate. [F4] Contrast Adjustment (light) invalid case color type This switch adjusts contrast LCD. When [F4] switch pressed once, color becomes light. this switch held down second, color changes rapidly into lightness. [F5] Backlight This switch turns backlight ZM-** OFF. want this function, have [Backlight] [Others] dialog [System Setting]. following list shows backlight function specified editing software. Backlight Auto Auto Function Switch (F5) Ignored. following actions added regular functions these items Even time does reach setting time, backlight will turn [F5] switch pressed (provided that 11(Backlight) Read Area level). (Refer Instruction Manual) select [Manual], backlight will turn only when this switch pressed. Also, specify item, [Backlight Power Time Control]. When turn power supply ZM-** [ON] backlight lit. [OFF] backlight off. Manual Terminal Converter (ZM-1TC) Size Terminal Converter (ZM-1TC) terminal converter ZM-1TC when connecting ZM-42/43/52/72/82 series RS-422/ terminal block. 34.7 Installation Make sure that power ZM-42/ 43/52/72/82 series OFF. Install ZM-1TC serial connector (CN1) ZM-42/43/52/ 72/82 series. Settle ZM-1TC module mounting screw. DC24V Unit Mounting Screw Unit Mounting Screw ZM-1TC (Terminal Converter) Tighten terminal screw, module mounting screw Tighten mounting screws with following torque. Position screws Screw size M2.6 Tighten torque 0.49 0.10.2 5.9MAX Pressure connection terminal (Unit 5.9MAX I/O, terminal screw Module mounting screw Never fasten these screws tightly, otherwise cover Control Terminal deformed. Terminal Converter (ZM-1TC) Connection Connecting RS-422 communicating cable Choose 4-line 2-line system ZM-1TC switch (SW1) Connect cable exists. Connect shield line resistance switch located back side ZM-** body. sure attached cover ZM-1TC when connection terminated. ZM-1TC up.four-wire (Above: 4-line system Below: 2-line system) case communicating other 4-line system ZM-1TC Signal name Communication data Communication data Communication data Communication data Shield RS4222 port link module ZM-1TC Signal name Sending/ receiving data Sending/ receiving data Shield 2-line system RS4222 port link module case multi-link 2-line system case jump side) ZM-1TC Signal name mination resistance (on) Shield ZM-1TC Signal name mination resistance (off) Shield ZM-1TC Signal name mination resistance (off) Communication data Communication data Communication data Communication data Shield RS4222 port link module 2-line system case doesn't have jump side) ZM-1TC Signal name mination resistance (on) Shield ZM-1TC Signal name mination resistance (off) Shield ZM-1TC Signal name mination resistance (off) Sending/ receiving data Sending/ receiving data Shield RS4222 port link module Expansion module (ZM-322M) Size Expansion module (ZM-322M) expansion module ZM-322M used ZM-72/82 series external (Input points, output points) Attached unit DI/DO connector Used connecting connector pin, mounting connection part expansion module. 125.5 Expansion module E-I/O UNIT Installation Take sticker avoid dust which pasted back side ZM-72/82 body, described drawing. Then, install ZM-322M mounting three parts unit screws. Install DI/DO (attached unit) connector connection part ZM-322M, mounting parts unit screws. Three parts screwing ZM-322M 100240VAC Tighten screw module Refer chart below use. Screw position Module mounting screw Screw size Tightening torque 0.290.49 Main body ZM-72/82 series Expansion module (ZM-322M) ZM-322M, refer {[P2] menu} [Chapter System Setting] ZM-71SE instruction manual. Position DI/DO connector positioning DI/DO connector follows. Connect referring drawing. DC24V DI/DO connector (attached connector) Input Output Input/output circuit circuit drawing input/output follows. Input circuit Input voltage Input Impedance Input electric current 3.3k 1.5k Internal circuit DC24V Output Circuit Voltageless connection type 3.3K Maximum Drive Remaining voltage 50mA VDC) 1.7V OUT0 Load Internal circuit OUT15 Load IN15 Card Recorder (ZM-1REC) Card Recorder (ZM-1REC) Used backup panel data recording memory manager function data longing function. condition display Memory card connector Modular connector adapter connector Memory Card connector SRAM flash memory card used described chart below. (JEIDA Ver4.0 Maker: Canon) SRAM card Flash memory card 256K, 512K, Bytes 256K, 512K, Bytes condition display Display battery voltage SRAM card. Green: battery voltage normal Red: battery voltage abnormal Modular Connector Connect with ZM-42/43/52/72/82 series attached cable. Adapter Connector When using external electricity, connect adapter. Cable transporting panel (ZM-80C) DOS/V PC98 PC98 Cable transporting panel (ZM-80C) ZM-80C cable that transports panel data between ZM-42/43/52/72/82 series well ZM-41/70 series personal computers. When using, need have Windows screen edit software ZM-71SE. convertible adapter ADP25-9 ADP25-M attached ZM-80C. Examples using cable convertible adapter. Types Computer Serial Connector Type D-sub 9pin D-sub 9pin D-sub 25pin Control Terminal ZM-42/43/52/72/82 Series drawing drawing ZM-41/70 drawing drawing drawing drawing (1), (Reference) When constructing using drawing (3), functions same product ZM-60C. System Composition Series (D-sub pin) DOS/V personal computer ZM-42/43/52/72/82 Series ZM-80C ADP25-9 Series (D-sub pin) D-sub 9pin Modular 8pin ADP25-M ZM-41/70 Series SYSTEM POWE D-sub 25pin D-sub 25pin length ZM-80C cable three meters. Printer Cable (ZM-80PC) Printer Cable (ZM-80PC) ZM-80PC cable that connects ZM-42/43/52/72/82 series printer. hard copy panel ZM-42/43/52/72/82 well registered list/ sampling data. ZM-42/43/52/72/82 Series Printer Half pitch 36pin Centronics 36pin length ZM-80PC cable meters. Port Adapter (ZM-1MD2) Port Adapter (ZM-1MD2) mounting port Mitsubishi ZM-1MD2 acts module that connects communicates between (programming tool) ZM-42/43/52/72/82 series. Since possible connect without link module Mitsubishi calculator, cost saving hardware machines became possible. Connection Connector (however, connect Control Terminal) Enlarged drawing Connector Series Connector port Slide switch when select connection model. series (ACPU port) series (QnA port) series (Note) Change slide switch before power supply. MITSUBISHI Series Series Connect connector which found back side directly port. A6GPP, A7PHP, personal computers, etc. SYSTEM POWE Series Port Adapter (ZM-1MD2) When connecting units together MITSUBISHI Series Series Connecting cable (Mitsubishi made optional) Connect connector which found back side directly port. SYSTEM POWE This becomes faster Series Slide switch when select connection model. series (ACPU port) series (QnA port) series (Note) Change slide switch before power supply. SYSTEM POWE Series Caution Since power supply ZM-1MD2 supplied from CPU, attention capacity power supply CPU. wiring, fully careful noise. There following restriction when ZM-1MD2 used series port. When using ZM40/61 series, re-try time seconds. communication time seconds between CPU.When communication error occurs between CPU, ZM-1MD2 maintains seconds communication time between CPU. After passing seconds, although communication port changed between CPUs, since seconds, re-try time ZM-40/60 series serves time-out, communication error occurs. Perform re-execution seconds after. When ZM-41/70/80 series, choose from following methods. With [Detail Setting] menu [Communication Parameter] [System Setup], [Communication error processing] "Continuation." [Time-out time]x [re-try time] become more than seconds. Write running When write-in operation running performed from side time required larger than seconds, ZM-1MD2 cannot used. this case, written STOP state addition, although number steps program which perform writing among less than seconds difference according contents program, computable following formula standard. Time (Number steps scan time (msec) standard asked this formula. addition, case constant scan, this formula cannot apply. When power supply switched where console connected ZM-1MD2, console will become communication time-out before completing initialization ZM-1MD2. When connects again reset operation console performed once removes cable console, will return normal state. (Normal operation this machine carried after seconds progress from time power supply injection.) When ZM-1MD2 series/FX series CPU, time-out time seconds more commu -nication parameter setup ZM41/70/80. Port Adapter (ZM-1MD2) Attached metal fittings ZM-1MD2 When connecting ZM-1MD2 small type (A1S, A2US, etc,) series made Mitsubishi, unit mounting attached metal fittings. MELSEC Axsxxx POWE MELSEC STOP ERROR L.CLR RESET RESET MITSUBISHI MITSUBISHI Insert metal fitting shown drawing. Size metal fitting Tighten correctly Unused (Used series large type, used when connecting series) MELSEC Axsxxx POWE MELSEC STOP ERROR L.CLR RESET RESET After inserting, tighten correctly MITSUBISHI MITSUBISHI 2Port Adapter (ZM-1MD2) Size drawing ZM-1MD2 24.1 8.08 Devise mounting screw 38.1 12.7 Seal Expansion Memory (ZM-4EM) Installation Expansion Memory (ZM-4EM) About 900K bytes (1.2 byte font use) inside flash memory that been installed main body ZM-52/72/82 series used panel data memory. install ZM-2EM/4EM main body ZM-52/72/82 series, additional 2M/4M bytes installed panel data memory.(ZM-2EM discontinued production.) Turn power. Take cover Take cover described drawing, install additional memory. Turn power. When installing memory, press hard both ends cassette case. 100240VAC Install expansion memory. ZM-52/72/82 There ways installing additional memory. case additional memory case expansion memory memory volume increases consequently Turn NO.1 volume memory cassette increases, lifting chart described below. case additional memory Turn NO.1 which locates back side ZM-52/72/82 series. Read data (font, interface driver, panel data) other than program already installed, additional memory itself. volumes panel data chart described below. (*2) When turning DIPSW NO.1, make sure that also recharge power ZM-52/72/82 series. ZM-52/72/82 Font Japanese Japanese English (Western) Chinese (Mandarin) Chinese (Simplified) Korean Standard 1,179,648 786,432 1,441,792 1,310,720 1,179,648 1,310,720 Additional Additional memory memory 3,260,416 5,357,568 2,867,200 4,964,352 3,522,560 5,619,712 3,391,488 5,488,640 3,260,416 5,357,568 3,391,488 5,488,640 Additional memory 1,703,936 1,179,648 1,835,008 1,703,936 1,703,936 1,835,008 Additional memory 3,801,088 3,276,800 3,932,160 3,801,088 3,801,088 3,932,160 This volume panel data when adding memory while turning NO.1. This volume panel data when adding memory while turning NO.1. Japanese matches font. case multiplying size character, character becomes softened base font. Setting screen edit software ZM-71SE, [additional memory] [2M(additional memory [4M(additional memory [2M(additional memory [4M(additional memory using [other setting (O)/P1] [system setting (A)]. Expansion Memory (ZM-43EM) Installation Expansion Memory (ZM-43EM) expansion memory ZM-43EM extension board used which increases screen data memory ZM-43T/43D/43L. When ZM-43T/43D/43L mounted, bytes screen data memory extended. Correspondense models ZM-43 series (ZM-43T/43D/43L) Software version version 1.2.0.0 later program version (SYSTEM PROG. VER.) ZM-43T/43D/43L. verison 1.2.0.0 later ZM-71SE. Please install ZM-43EM ZM-43T/43D/43L (the following main body) following procedure. Turn power. Take cover cassette part connect with expansion memory install ZM-43EM. When installing memory, press hard both ends ZM-43EM. switch main body side according purpose use. Refer next page "Kinds memory expansion". power supply main body turned Take cover Install expansion memory. 24VDC main body case expansion memory Turn NO.1 lifting DIPSW Expansion Memory (ZM-43EM) Kinds memory expansion ZM-43EM, there kinds extension methods (additional memory according setup switch ZM-main body. Additional memory DIPSW main body. shown following table (*1), amount memories increases capacity ZM-43EM. Additional memory DIPSW main body. Data (font, driver, screen data) other than program main body written ZM-43EM. capacity screen data shown following table (*2). Standard Font Japanese Japanese English (Western) Chinese (Mandarin) Chinese (Simplified) Korean 1216 1408 1280 1216 1344 Additional memory 5248 4800 5440 5312 5248 5376 Additional memory 3712 3264 3904 3776 3712 3840 (Unit bytes) This volume panel data when adding memory while turning "1". This volume panel data when adding memory while turning "1". Japanese matches font. case multiplying size character, character becomes softened base font. (Note When turning DIPSW "1", make sure that also recharge power main body. Setting main body screen edit software ZM-71SE, [additional memory] [4M(additional memory [4M(additional memory using [other setting (O)/P1] [system setting (A)]. Expansion Memory (ZM-43SM, ZM-80SM) Expansion Memory (ZM-43SM, ZM-80SM) expansion memory ZM-43SM/80SM memory extension which calendar SRAM backup memory ZM-43/52/72/82 were carried. Model name ZM-43SM ZM-80SM Correspondense model ZM-43 series ZM-52/72/82 series This expansion memory cannot used ZM-42 series. component ZM-43SM/80SM follows. ZM-43SMZM-80SM Accessories Coin type lithium primary battery (type CR2430): Caution seal: Safety precautions Since lithium battery used ZM-43SM/80SM contains inflammable substances, such lithium organic solvent, handling mistaken, generation-of-heat burst ignition etc., injured possibility resulting fire. Caution Perform exchange battery after discharging static electricity collected human body. battery appointed "form" "model name" time exchange battery. other batteries used, will become cause fire explosion. works hard with battery single article currently used this equipment, will become cause causing fire chemical combustion. battery into fire, heat decompose. terminal, please twist tape, insulate dispose used battery correctly. Keep battery place which does reach infantile hand. should understand, please consult with doctor immediately.) make battery short-circuit. charge battery means. carry direct soldering battery. Make battery reverse them. Since there possibility igniting escaped electrolysis liquid when battery leak there nasty smell, please keep away from fire immediately. Handling precautions sure attach battery when used ZM-43SM/80SM. Since data ZM-43SM/80SM held unless power supply supplied ZM-43SM/80SM. version 1.1.0.2 later ZM-71SE, version1.200 later, program version ZM-43/ 52/72/82, version1.100/1.090/1.000 later, font data version. Expansion Memory (ZM-43SM, ZM-80SM) Installation Please attach ZM-43SM/80SM ZM-43/52/72/82 following procedure. battery (CR2430) attached article turned socket ZM-43SM/80SM, side turned upwards, sets. case sets, battery pushed plug direction side, side also inserts side. SANYO Type :ZM43SM/RS :XXXXXXX date five years after entered "next battery exchange day" column cautions seal attached article, shown following figure, sticks Type :ZM-43SM/RS :XXXXXXX operating maintenance instruction type battery used. Battery replacement. SM/R tructi rati main tena ttery repla ent. SANYO CR2430 [Caution seal] Write date five years after. term validity battery ZM-43SM/80SM about five years degrees. Even less than five years, when voltage battery falls, internal memory (address #s167) ZM-43/52/72/82 turns warns battery exchange. Please exchange batteries quickly. $s167 CR2430 SANYO CR2430 side power supply ZM-43/52/72/82 turned OFF. cover expansion memory cassette part removed ZM-43SM/80SM attached. inst ruct atin type used tery repl emen Take cover. 100240VAC main body (The above diagram ZM-72/82) Setting main body screen edit software ZM-71SE, [SRAM cassette setup (W)] [System setup(A)] chosen, [SRAM cassette setting] dialog When change setup, please sure format. following procedure performs adjustment format date ZM-43SM/80SM, time. [local main] screen ZM-43 main part displayed. "cassette adjustment" switch [local main] screen pushed. [cassette adjustment] screen displayed. Adjustment format date time performed here. Reserve memory cassette information (Setting installed Expansion memory (2M) Expansion memory (4M) SRAM+ clock cassette Reserve memory cassette information (Setting Battery failure (Necessory exchange battery.) Install SRAM casette. Expansion Memory (ZM-43SM, ZM-80SM) exchange method battery should prepare following battery exchange, exchanges following procedure. Model type CR2430 Specifications Coin type lithium primary battery (recommend made SANYO) case battery exchange carried out, ZM-71SE used (cable ZM-80C) backup data stored ZM-43SM/80SM taken. ZM-71SE started. [Transmission] icon clicked. [Transmission] dialog displayed. [transmission device:main part] [transmission data:SRAM data] chosen. When taking backup from ZM-71SE Ethernet server, address] transmission SRAM wearing main body chosen [Ethernet. item [which uses simulator] [which takes comment time reception] left [PC] button [transmission method] clicked. read data saved [*.RAM] file. power supply main body turned cautions seal ZM-43SM/80SM removed, battery mounted socket will appear. battery removed from socket exchanged battery. (Refer previous page "Installation".) power supply main body turned file saved transmitted ZM-43SM/ 80SM. Specifications General specifications Item Power Model ZM-43SM ZM-80SM (Power supply from ZM-43/52/72/82) max. (non condensation) dust Without corrosive 57.5 Black PC/ABS resin Gray Operation temperature Circumference temperature Relative humidity Dust Corrosive Outside dimensions Case color Material Memory specifications Item Kinds memory Memory capacity SRAM Kbytes Specifications Backup specifications Item Battery speicifications Specifications Coin type lithium primary battery Battery type CR2430 (recommend: Sanyo) Backup term Exchange propriety Battery voltage detection function Calender accuracy About five years (Circumference temperature Available (install socket battery Provided (Internal memory allocation) Monthly difference seconds (Circumference temperature (Note) When ZM-43/52/72/82 series printer always connected ZM-43SM/80SM being used time use, case turn power supply main body, please sure turn power supply printer.If power supply printer changed into state, response surroundings lump influence, consumption current backup battery ZM-43SM/80SM will increase voltage from signal line printer, backup battery will exhausted months. Connection Link Module Sharp MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI OMRON OMRON HITACHI HITACHI Matsushita YOKOGAWA YOKOGAWA YASKAWA YASKAWA TOYOPUC FUJI FUJI FUJI FUJI Koyo Allen-Bradley Allen-Bradley Fanuc Fanuc TOSHIBA TOSHIBA MACHINE SIEMENS SIEMENS SIEMENS SIEMENS SIEMENS Shinko SAMSUNG KEYENCE KEYENCE KEYENCE FANUC FATEK AUTMATION IDEC MODICON YAMATAKE TAIAN Sharp Sharp Link module following link module communication port that possibly connected. ZM-71SE Model Setting W70H, W100H JW50, JW70, JW100 JW50H, JW70H, JW100H JW20, JW20H JW30H JW10 JW-1324K/1342K JW-1424K/1442K JW-1624K/1642K J-board JW70(JW-70CU) JW100(JW-100CU) JW70H(JW-70CUH) JW100H(JW-100CUH) JW20(JW-22CU) JW20H(JW-22CU) JW30H JW-32CUH/H1 JW-33CUH/H1/H2/H3 JW20 (Z-311J Z-312J) J-board (Z-511J) (Z-512J) Upper Communication Port Upper Communication Port Upper Communication Port Upper Communication Port TC12 PG/COMM1 Port PG/COMM2 Port PG/COMM1 Port PG/COMM2 Port Link module ZW-10CM JW-10CM Series JW-21CM Port Communication Port Z-331J/332J JW70H Communication Port setting items described chart below. Item Baud Rate Data Length Parity Stop Error Check RS-422 Transmission Control Port Content settings Same main unit (normal 19200bps) Even Sumcheck 4-wire system Command mode [01] Sharp Switch Setting Link module Switch setting ZW-10CM, JW-10CM JW-21CM Switch SW3-1 SW3-2 SW3-3 SW3-4 Switch setting Z-331J/332J Switch SW3-1 SW3-2 SW3-3 SW3-4 Setting Computer link Station address (lower half) Station address (upper half) used Used only 2-line system used Even parity Baud rate:19200 Temination resistance provided Contents Setting Comand mode Station address (lower half) Station address (upper half) used 4-wire system used Even parity Baud rate:19200 Temination resistance provided Contents System Memory Setting case communication port] System memory setting JW-70CU/100CU, JW-70CUH/100CUH Z-311/312J System memory Setting Stop bit, #236 Parity Even Baud rate:19200 #237 Station address Contents Sharp System memory setting JW-32CUH/H1/M1, JW-33CUH/H1/H2/H3, Z-51J/512J Communication port (PG/COMM port) System memory Setting Stop bit, #234 Parity Even Baud rate:19200 #235 Station address Contents Communication port (PG/COMM port) System memory Setting Stop bit, #236 Parity Even Baud rate:19200 #237 Station address Contents System memory setting JW-1324K/1342K, JW-1424K/1442K JW-1624K/1642K Communication port System memory #234 Setting Computer link Stop bit, Parity Even #236 Baud rate:19200 Data Length #237 Station address Contents port System memory Setting Stop bit, Parity Even #226 Baud rate:19200 Data Length #227 Contents Station address Sharp Available Memory Available: Memory X9XXX (Register) XXXXX (Relay) EXXXX (Register [Self-diagnosis]) bXXXX (Timer/Counter [current value) (File Register) (File Register) (File Register) Write TYPE Unavailable: Remarks word device [Caution] attention following cautions when applying indirect address-assign macro command register x9xxx(memory type (Refer P14-23 ZM-71SE instruction manual) When applying ZM-70/41 least before V1.10 after V1.15 system version (You V1.11~ V1.14 versions) memory-assign method between register 09000 19000 done 512-word unit. When applying ZM-82/72/52/43/42, ZM-71T memory-assign method between register 09000 19000 done 256-word unit regardless versions. relation between register address memory No.(in case indirect address- assign) (the memory shown word unit.) Model Version Register address 09000~09776 19000~19776 29000~29776 39000~39776 49000~49776 59000~59776 69000~69776 79000~79776 89000~89776 99000~99776 ZM-70/41 before V1.10 after V1.15 Memory (DEC) 0~255 512~767 1024~1279 1536~1791 2048~2303 2560~2815 3072~3327 3584~3839 4096~4351 4608~4863 ZM-82/72/52/43/42 ZM-71T versions Memory (DEC) 0~255 256~511 512~767 768~1023 1024~1279 1280~1535 1536~1791 1792~2047 2048~2303 2304~2559 Sharp Wiring Indicate connection ZM-** each module. used alternately with RS-422. RS-422 Connection with ZW-10CM, JW-10CM JW-21CM ZM-** (CN1) Signal name ZW-10CM JW-10CM JW-21CM Signal name SHIELD Earth twist shielded cables Connection with JW-70CU/100CU, JW-70CUH/100CUH, JW-22CU JW-22CU JW-70CU/100CU JW-70CUH/100CUH (Communication Port) Signal name ZM-** (CN1) Signal name twist shielded cables (Attention case JW-70CUH/100CUH, connect resistance.) (Connect No.6 communication port with No.13.) Connection with Z-311J/312J ZM-** (CN1) Signal name Z-311J/312J (Host communication port TC1) Signal name twist shielded cables Connection with Z-511J ZM-** (CN1) Signal name Z-511J (CN8 CN12) Signal name RD(+) RD(-) SD(+) SD(-) 9(4) 10(5) 3(2) 11(3) 1(1) twist shielded cables CN12 number parentheses Sharp Connection with JW-32CUH/H1, JW-33CUH/H1/H2/H3, Z-512J JW-32CUH/H1 JW-33CUH/H1/H2/H3 Z-512J PG/COMM1 Port PG/COMM2 Port Signal name ZM-** (CN1) Signal name twist shielded cables Connection with JW-1324K/1342K, JW-1424K/1442K, JW-1624K/1642K case connecting communication port] JW-1324K/1342K JW-1424K/1442K JW-1624K/1642K (Communication Port) Terminal name ZM-** (CN1) Signal name SHLD twist shielded cables (Attention termination resistance switch naught (off) termination resistance) [When connecting port] ZM-** (CN1) Signal name JW-1324K/1342K JW-1424K/1442K JW-1624K/1642K (MMI Port) Signal name twist shielded cables (Attention: termination resistance switch naught (off) termination resistance) Connection with Z-331J/332J ZM-** (CN1) Signal name Z-331J/332J (Host communication port Terminal name twist shielded cables Sharp RS-232C Connection with JW-70CU/100CU, JW-70CUH, JW-22CU JW-22CU JW-70CU/100CU JW-70CUH/100CUH (Communication Port) Signal name Short Terminal ZM-** (CN1) Signal name Used shielded cables Connection with Z-311J/312J Z-311J/312J (Host communication port Signal name Short Terminal ZM-** (CN1) Signal name Used shielded cables Connection with JW-32CUH/H1, JW-33CUH/H1/H2/H3 JW-32CUH/H1 JW-33CUH/H1/H2/H3 (PG/COMM2 port) Signal name ZM-** (CN1) Signal name twist shielded cables MITSUBISHI MITSUBISHI (A/Q series link unit) Available ZM-71SE Model Setting A2A, Link Unit AJ71C24-S6 AJ71C24-S8 AJ71UC24 AJ71UC24 AJ71C24 AJ71C24-S3 AJ71C24-S6 AJ71C24-S8 AJ71UC24 A0J2C214-S1 A1SJ71UC24-R2 Wiring Diagram (refer P2-12, A2U, A3U, A1N, A2N, A3H, A3M, AnA/N/U series A0J2, A0J2H A2US RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram RS-232C [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-422 [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram A1SJ71UC24-R4 A1SJ71UC24-PRF A1SJ71C24-R2 A1S, A1SJ, A1SJ71C24-R4 A1SJ71C24-PRF A2CCPUC24 QnH(A mode) built-in port A1SJ71UC24-R2 A1SJ71UC24-R4 AJ71QC24N series Q2A, Q3A, Q2ASx AJ71QC24 A1SJ71QC24 AJ71QC24-R4(CH1) AJ71QC24-R4(CH2) QnH(Q mode) QJ71C24 MITSUBISHI Communication Setting recommended communication parameter setting both ZM-** follows: series link unit Item Baud Rate Port Parity Setting 19200bps both STATION Even RS-232C RS-422 Data Length Stop MODE1 MODE5 (ASCII) Provided Available Provided Provided Comm. Parameter ZM-** 19200bps Even Trans. Mode Trans. Mode Transmission Control Mode Transmission Code Sumcheck Write while running Terminal Resistor Sender Terminal Resistor Receiver [Trans. Mode selected from [Trans. Mode] [Comm. Parameter] panel editor, specify [MODE4] case RS-232C, select [MODE8] case RS-422. series link unit Item Baud Rate Port Parity Transmission Control Mode Transmission Code RS-232C RS-422 Data Length Stop Provided Available Setting 19200bps both STATION Even MODE5 (Binary Mode) Comm. Parameter ZM-** 19200bps Even Sumcheck Write while running MITSUBISHI Switch Setting following example show settings both rotary switches switches <E.g.> Signal Level: RS-232C, Baud Rate: 19200bps, Trans. Mode: Trans. Mode SW11 SW12 AJ71UC24 STATION STATION MODE SW13 SW14 SW15 SW16 SW17 SW18 SW21 SW22 SW23 SW24 <E.g. Signal Level: RS-232C, Baud Rate: 19200bps, Trans. Mode: Trans. Mode A1SJ71C24-R2 A1SJ71UC24-R2 STATION STATION MODE SW03 SW04 SW05 SW06 SW07 SW08 SW09 SW10 SW11 SW12 <E.g. Baud Rate: 19200bps AJ71QC24 A1SJ71QC24 AJ71QC24N STATION STATION MODE SW01 SW02 SW03 SW04 SW05 SW06 SW07 SW08 SW09 SW10 SW11 SW12 <E.g. Signal Level: RS-422, Baud Rate: 19200bps, Trans. Mode: Trans. Mode SW01 A1SJ71UC24-R4 A1SJ71C24-R4 SW02 STATION STATION MODE SW03 SW04 SW05 SW06 SW07 SW08 SW09 SW10 SW11 SW12 MITSUBISHI Available Memory Available: Unavailable: Memory (data register) (link register) (file register) (timer/current value) Write TYPE Slot Remarks (counter/current value) (special unit) (internal relay) (latch relay) (link relay) (input relay) (output relay) (timer/contact) (timer/coil) (counter/contact) (counter/coil) (link buffer) (special register) Only Only Only Only Only (special relay) (special link relay) (special link register) (file register [continuous access]) slot number required addition memory type address. Convert byte address into word address enter data memory device link unit byte address. memory extent memory range each model. case using memory device [Output Action] [Momentary other [Bit Write] bits will cleared when memory output, because [Bit Write] will output word (refer P5-10, reference 14-7 ZM-71SE Instruction Manual). [TYPE] number assign indirect memory macro programs. MITSUBISHI Wiring following diagram show wiring cable which connects ZM-** RS-232C Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: D-sub 9pin(Male: twist shielded cables. Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: D-sub 25pin(Male: twist shielded cables. MITSUBISHI RS-422 Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: twist shielded cables. Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: D-sub 25pin(Male: DSRA DTRA DSRB DTRB twist shielded cables. MITSUBISHI MITSUBISHI (A/QnA series port) Connection Connect A/QnA series port. communication parameter setting ZM-** done automatically. Available ZM-71SE Model Setting A2A, A2U, A3U, A2US(H) A1N, A2N, A3V, A3H, A0J2H A1S, A1SJ(H), A2S(H) A2CCPUC24 A1FX Q2A, Q3A, Q2AS(H) Wiring Diagram (refer P2-17) port RS-422 [Wiring Diagram port When updated, specifications changed, there some possibility that ZM-** cannot connected MITSUBISHI Available Memory Available: Unavailable: Memory (data register) (link register) (file register) (timer/current value) Write TYPE Slot Remarks (counter/current value) (special unit) (internal relay) (latch relay) (link relay) (input relay) (output relay) (timer/contact) (timer/coil) (counter/contact) (counter/coil) (special register) Only Only Only Only Only (special relay) (special link relay) (special link register) (file register [continuous access]) slot required addition memory type address. Convert byte address into word address enter data memory device link unit byte address. memory extent memory range each model. case using [Bit Write] memory device [Output Action] [Momentary other bits will cleared when memory output, because [Bit Write] will output word (refer P5-10, reference 14-7 ZM-71SE Instruction Manual). [TYPE] number assign indirect memory macro programs. MITSUBISHI Notes direct connection with port series Note According noise tests, attachment ferrite core improves noise voltage 900V aids preventing communication errors. safer operation, sure attach ferrite core cable. Take appropriate measures eliminate noise from entering communication cable between ZM-** MITSUBISHI A/QnA series CPU. Noise should considered when wiring electric machine. sure keep ZM** wiring sufficiently away from power cables. longer communication cable more likely noise influence; therefore, cable length should minimized much possible. File register(R) cannot used case operation series CPU. noise filter(ferrite core) sold optional accessory. series series Connect port. 20mm <Ferrite Core (noise filter)> Attach this noise filter close connector possible. <Cord Band> secure noise filter, attach cord band close bottom. Ferrite core consideration such noise problems, recommended that standard type link module used. MITSUBISHI Notes using ZM-1MD2 (Dual Port Interface) (See page 1-60) ZM-1MD2 powered CPU, check that electric capacity (power consumption: max. 350mA). distance between ZM-1MD2 should short possible (max. 1~1.5m). wiring, take appropriate measures eliminate noise. MITSUBISHI A/QnA Series A6GPP, A7PHP, personal computer, etc. case direct connection with port A/QnA series,plug rear connector port, exclusive cable(*). Exclusiue cable (order product) Slide switch series series series this switch before power supply ZM-** Wiring following diagram show wiring cable which connects ZM-** RS-422 Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: +RTS -RTS -CTS +CTS D-sub 25pin(Male: twist shielded cables. +RxD +TxD +DSR +DTR -RxD -TxD -DSR MITSUBISHI Connection MITSUBISHI (QnH series port) Connect series port. communication parameter setting ZM-** done automatically. Available ZM-71SE Model Setting QnHCPU port(A) Wiring Diagram (refer P2-19) Q06H-A Q02H Q06H RS-232C exclusive cable (order product) QnHCPU port(Q) When updated, specifications changed, there some possibility that ZM** cannot connected PLC. MITSUBISHI Available Memory Available: Unavailable: Memory (data register) (link register) (file register) (timer/current value) Write TYPE Unit Remarks (counter/current value) (special unit) (internal relay) (latch relay) (link relay) (input relay) (output relay) (timer/contact) (timer/coil) (counter/contact) (counter/coil) (special register) only mode only mode only mode only mode only mode (special relay) (special link relay) (special link register) (file register [continuous access]) unit number required addition memory type address. Convert byte address into word address enter data memory device link unit byte address. memory extent memory range each model. case using [Bit Write] memory device [Output Action] [Momentary other bits will cleared when memory output, because [Bit Write] will output word (refer P5-10, reference 14-7 ZM71SE Instruction Manual). [TYPE] number assign indirect memory macro programs. Wiring RS-232C cable, [QCPU2](2, 15m), made Sharp Corporation. MITSUBISHI MITSUBISHI (FX1/2 series) Connection Connect series port. communication parameter setting ZM-** done automatically. Available ZM-71SE Model Setting Wiring Diagram (refer P2-22) RS-232C exclusive cable (order product) RS-422 exclusive cable (order product) [Wiring Diagram RS-422 exclusive cable (order product) FX1/2 series series FX0N(tool port) When updated, specifications changed, there some possibility that ZM-** cannot connected Available Memory Available: Unavailable: Memory (data register) (timer/current value) Write TYPE Read only Remarks (counter/current value) 32CN (counter 32bits) (internal relay) (state) (input relay) (output relay) (timer/contact) (counter/contact) (data register) case items which display double word data (e.g. data display, graph, sampling), data managed double word data. Both data word data managed lower-half bits data. Input upper-half bits ignored. Output written upper-half bits. When D1000 2999, select memory extent memory range each model. case using [Bit Write] memory device [Output Action] [Momentary other bits will cleared when memory output, because [Bit Write] will output word (refer P5-10, reference 14-7 ZM-71SE Instruction Manual). [TYPE] number assign indirect memory macro programs. MITSUBISHI Notes direct connection with port series Note According noise tests, attachment ferrite core improves noise voltage 900V aids preventing communication errors. safer operation, sure attach ferrite core cable. Take appropriate measures eliminate noise from entering communication cable between ZM-** MITSUBISHI series CPU. Noise should considered when wiring electric machine. sure keep ZM** wiring sufficiently away from power cables. longer communication cable more likely noise influence; therefore, cable length should minimized much possible. noise filter(ferrite core) sold optional accessory. series Connect port. MELSEC FX2-24MT TRANSISTOR UNIT POWER BATT.V <Ferrite Core (noise filter)> Attach this noise filter close connector possible. 20mm <Cord Band> secure noise filter, attach cord band close bottom. Ferrite core Notes using ZM-1MD2 (Dual Port Interface) ZM-1MD2 powered CPU, check that electric capacity (power consumption: max. 350mA). distance between ZM-1MD2 should short possible (max. 1.5m). wiring, take appropriate measures eliminate noise. Specify value more than (=1.5 sec) [Time-out Time] [Comm. Parameter] case connecting ZM-** ZM-1MD2. MITSUBISHI series A6GPP, A7PHP, personal computer, etc. MELSEC FX2-24MT TRANSISTOR UNIT POWER BATT.V case direct connection with port FX1/2 series, exclusive cable(order product). Exclusive cable (order product) Slide switch series series series this switch before plugging ZM-1MD2. ZM-** Wiring following diagram show wiring cable which connects ZM-** RS-232C case connecting, with RS-232C, exclusive cable (order product 3m). RS-422 case connecting, with RS-422, exclusive cable (order product Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: +RTS -RTS -CTS +CTS twist shielded cables. D-sub 25pin(Male: +RxD +TxD +DSR +DTR -RxD -TxD -DSR MITSUBISHI MITSUBISHI (FX2N/0N protocol) Available ZM-71SE Model Setting Link Unit FX2N-232-BD Wiring Diagram(refer P2-25) RS-232C [Wiring Diagram RS-485 [Wiring Diagram RS-422 exclusive cable (order product) RS-232C [Wiring Diagram RS-485 [Wiring Diagram series protocol) FX2N FX2N-485-BD FX2N-422-BD FX0N-232ADP FX0N FX0N-485ADP Communication Setting recommended communication parameter setting both ZM-** follows: Item Baud Rate Parity Transmission Code Data Length Stop Setting 19200bps Even Exclusive Protocol Communication Comm. Parameter ZM-** 19200bps Even Function Type Sumcheck Transmission Control Mode Normally RS-232C Provided MODE Transmission system When link unit, FX2N-485-BD, FX2N-422-BD, FX2N-485-ADP used, select [RS-485] [Signal Level]. [Detail Setting] menu [Comm. Parameter] dialog ZM-**, setting value more than [Send Delay Time] recommended. MITSUBISHI Available Memory Available: Unavailable: Memory (data register) (timer/current value) Write TYPE Read only Remarks (counter/current value) 32CN (counter 32bits) (internal relay) (state) (input relay) (output relay) (timer/contact) (counter/contact) meaning CN200~CN255 same meaning 32CN(counter 32bits). case items which display double word data (e.g. data display, graph, sampling), data managed double word data. Both data word data managed lower-half bits data. Input upper-half bits ignored. Output written upper-half bits. memory extent memory range each model. case using [Bit Write] memory device [Output Action] [Momentary other bits will cleared when memory output, because [Bit Write] will output word (refer P5-10, reference 14-7 ZM-71SE Instruction Manual). [TYPE] number assign indirect memory macro programs. MITSUBISHI Wiring following diagram show wiring cable which connects ZM-** RS-232C Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: twist shielded cables. D-sub 9pin(Female: Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: twist shielded cables. D-sub 25pin(Male: RS-485 Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: twist shielded cables. MITSUBISHI MITSUBISHI (FX2N series) Connection Connect series port. communication parameter setting ZM-** done automatically. Available ZM-71SE Model Setting FX2N series FX2N Wiring Diagram RS-422 exclusive cable (order product) When updated, specifications changed, there some possibility that ZM-** cannot connected Available Memory Available: Unavailable: Memory (data register) (timer/current value) Write TYPE Read only Remarks (counter/current value) 32CN (counter 32bits) (internal relay) (state) (input relay) (output relay) (timer/contact) (counter/contact) case items which display double word data (e.g. data display, graph, sampling), data managed double word data. Both data word data managed lower-half bits data. Input upper-half bits ignored. Output written upper-half bits. memory extent memory range each model. case using [Bit Write] memory device [Output Action] [Momentary other bits will cleared when memory output, because [Bit Write] will output word (refer P5-10, reference 14-7 ZM-71SE Instruction Manual). [TYPE] number assign indirect memory macro programs. Wiring RS-422 case connecting, with RS-422, exclusive cable (order product MITSUBISHI MITSUBISHI (Net ZM-** access other CPUs II(/B) NET/10 when ZM-** connected link units that data link system network system consists Select "Net10" setting when configuring screen data panel editor. access other (/B) NET/10 from ZM-**. case II(/B), only network which with link unit connected ZM-** (e.g. accessed. (Available No.: 0~30) case NET/10, other networks (No. accessed addition network (Available No.: 1~30) read/write memories CPU(e.g. CPU) which link unit connected ZM-**: Link Unit ZM-** (1-5) (1-2) (2-2) (1-1) (2-1) (2-5) "31" panel editor. Response time will equivalent case communication. Please note that response will delayed transient transmission when other than "31". Network Network (1-4) (1-3) (3-2) (2-3) (3-1) (2-4) Network (3-5) this case, [OUT_ENQ] command [SYS] program macro. from different network cannot accessed same screen. When accessing other network numbers NET/ specify network number connected with screens Open Macro Panel Editor. (3-3) (3-4) MITSUBISHI Macro type specify network [OUT_ENQ] command [SYS] Memory (fixed) Specify network: (fixed) System code Network addresses fixed Specify [System code] NET/10 II(/B) Enter [Network No.] when [System code] indicates "2", "the number accessed" [Network No.] when [System code] indicates "1". macros include this command except Open Macro. Communication error will occur execution netware change when this command used other kinds macros. Refer "ZM-71SE Instruction Manual" further information Macro. Also refer MITSUBISHI's manual network registration. MITSUBISHI's manual details II(/B) data link system NET/10 network system. Available Memory P2-9, "A/Q series link units" P2-15, "A/QnA series port" available memory accessed. Note that should screen edit software ZM-71SE. Wiring wiring diagrams P2-12, 2-13, MITSUBISHI OMRON OMRON Available ZM-71SE Model Setting C20H, C28H, C40H C120, C120F C200H C500, C500F C1000H C2000, C2000H C200H C200HS-CPU01,03 C200HS-CPU21,23 C200HS-CPU31,33 Link Unit unit with built-in RS-232C port (host link port) Wiring Diagram (refer P2-28, RS-232C [Wiring Diagram C120-LK201-V1 C120-LK202-V1 RS-232C [Wiring Diagram RS-422 [Wiring Diagram C200H-LK201 C200H-LK201-V1 C200H-LK202 C200H-LK202-V1 RS-232C [Wiring Diagram RS-422 [Wiring Diagram SYSMAC C200HS-CPU21,23 C200HS-CPU31,33 unit with built-in CQM1-CPU21 RS-232C port (host link port) CQM1-CPU41, C500, C500F C1000H C2000, C2000H C200HX C200HG C200HE C500-LK203 RS-232C [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram Cable made OMRON [CQM1-CIF01]* RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C PORT1 [Wiring Diagram PORT2 [Wiring Diagram RS-422 PORT2 [Wiring Diagram RS-232C [Wiring Diagram RS-232C [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram unit with built-in RS-232C port (host link port) Communication board (C200HW-COM02~06) RS-232C interface unit (peripheral port) unit with built-in RS-232C port (host link port) SRM1-C02 CPM1A SYSMAC CV500, CV1000 CV2000 CVM1 CV500-LK201 unit with built-in RS-232C port (host link port) SYSMAC CS1W-SCU21 Communication board (CS1W-SCU41) Cannot connected ZM-** multi-link connection. Exchange shell, side D-sub25. (recommendation 17J-25 made DDK) OMRON Communication Setting recommended communication parameter setting both ZM-** follows: Item Baud Rate Port Parity Transmission Code Data Length Stop Setting 19200bps Even (ASCII) Internal Synchronization (normally RS-422 Comm. Parameter ZM-** 19200bps Even Command Level :1/1 Protocol Synchronizing Switch Switch Supply Switch Terminal Resistor [SYSMAC selected [Select Type] dialog, [Trans. Mode] [Detail] [Comm. Parameter] ZM-71SE. When using (extensional data memory), specify bank number assigned memory indicated while editing screen illustrated: Trans. Mode Trans. Mode Trans. Mode Contents sign w/+/- sign w/+/- sign possible display data data with signs When higher bits memory treat data minus data. regards higher bits memory [-0] regards higher bits memory [-1] range word -1999 +9999 words -19999999 +99999999 <Ex.> memory 0000 9999 F001 F999 A000 A999 00000000 99999999 F0000001 F9999999 A0000000 A9999999 Display ZM-** 9999 -999 -1000 -1999 99999999 -9999999 -10000000 -19999999 Num. Display [Input Type] [Display Type] DEC(w/ -sign, +sign) OMRON Available Memory Available: Unavailable: Memory (data memory) (input/output relay) (holding relay) (latch relay) (alarm relay) (timer/current value) (counter/current value) (timer [contact]) (counter [contact]) Write TYPE Read only Read only Remarks Available: Unavailable: Memory (data memory) (input/output relay) (alarm relay) (timer/current value) (counter/current value) Write TYPE Read only Read only Remarks (extensional data memory) (timer [contact]) (counter [contact]) Available: Unavailable: Memory (data memory) (input/output relay) (alarm relay) (timer/current value) (counter/current value) Write TYPE Read only Read only Remarks (extensional data memory) (internal relay) (timer/contact) (counter/contact) When using (extensional data memory), specify bank number (CV:0 CS1:0 assigned memory indicated while editing screen illustrated: <E.g.> EM0:30000 Address Bank OMRON memory extent memory range each model. case using [Bit Write] memory device [Output Action] [Momentary other bits will cleared when memory output, because [Bit Write] will output word (refer P5-10, reference 14-7 ZM-71SE Instruction Manual). [TYPE] number assign indirect memory macro programs. Wiring following diagram show wiring cable which connects ZM-** RS-232C Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: twist shielded cables. D-sub 9pin(Male: Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: twist shielded cables. D-sub 25pin(Male: Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: twist shielded cables. D-sub 25pin(Male: OMRON RS-422 Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: D-sub 9pin(Male: twist shielded cables. Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: D-sub 9pin(Male: twist shielded cables. Wiring Diagram ZM-*2 (CN1) D-sub 25pin(Male: D-sub 9pin(Male: twist shielded cables. Wiring Diagram ZM-** (CN1) D-sub 25pin(Male: twist shielded cables. D-sub 9pin(Male: OMRON OMRON (OMRON-CS1 DNA) (1-2) (2-2) When connect ZM-** network, ZM-** also access other network. Network No.1 (1-3) (2-1) Network No.2 (2-3) (1-1) (2-4) Available ZM-71SE Model Setting Link Unit unit with built-in RS-232C port (host link port) SYSMAC CS1W-SCU21 Communication board (CS1W-SCB41) Wiring Diagram (refer P2-32,33) RS-232C [Wiring Diagram RS-232C [Wiring Diagram RS-232C [Wiring Diagram RS-422 [Wiring Diagram Cannot connected ZM-** multi-link connection. Available Memory [Available Memory] OMRON Wiring [Wiring] OMRON ZM-71SE Setting Select [System Setting] from [Item], click [Comm. Parameter]. [Comm. Parameter] dialog displayed. [Connection] [1:n] [Detail] window. Select [System Setting] from [Item], click [Network Table]. [Edit Network Table] displayed. Double click [No.]. dialog displayed. Register network. Double click HITACHI HITACHI (HIDIC series) Available ZM-71SE Model Setting Link Unit COMM-2H PERIPHERAL port module HIDIC-H HIDIC series EH150 Wiring Diagram(refer P2-37) RS-232C [Wiring Diagram RS-422 [Wiring Diagram RS-232C [Wiring Diagram [EH-RS05] cable made HITACHI RS-232C [Wiring Diagram PERIPH Other recent searchesZFBBA05C2 - ZFBBA05C2 ZFBBA05C2 Datasheet REJ03B0230-0110 - REJ03B0230-0110 REJ03B0230-0110 Datasheet INA219 - INA219 INA219 Datasheet HM5164400A - HM5164400A HM5164400A Datasheet HM5165400A - HM5165400A HM5165400A Datasheet AN2700 - AN2700 AN2700 Datasheet
Privacy Policy | Disclaimer |