ceramic sensor viscous pasteous media accuracy: 0.25 BFSL (0.5 60770)


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Pressure Transmitter with Flush Stainless Steel Diaphragm
ceramic sensor viscous pasteous media accuracy: 0.25 BFSL (0.5 60770) nominal pressure ranges from
pressure transmitter process measurement. Because flush diaphragm suited viscous media gases, which compatible stainless steel 1.4435 (316L) sealing material. Basic element ceramic sensor, which features small thermal effect, good linearity long term stability. Different filling fluids available: besides silicon oil, food compatible oil, Halocarbon; others available request. usage higher temperatures cooling element delivered optionally. Different output signals electrical connections make covering wide field applications. Additional pressure transmitter used explosive area. Preferred areas are: process engineering chemical industry food industry paper industry
small thermal effect good linearity good long term stability option version: (only 2-wire) ATEX 2006 customer specific versions: variety electrical mechanical connections other versions request
Flush Pressure Transmitter
Characteristics
Flush Pressure Transmitter
Technical Data
Input pressure range
Nominal pressure gauge [bar] Nominal pressure abs. [bar] Permissible overpressure [bar]
-1.0
Output signal Supply
Standard Optional 2-wire: 3-wire: Ex-protection:
Performance
Accuracy Permissible load 60770 current 2-wire: current 3-wire: voltage 3-wire: supply: load: msec Rmax [(VS min) 0.02] Rmax Rmin 0.05 0.05 BFSL: 0.25
Influence effects Response time
Thermal effects
Thermal error offset span compensated range
(Offset Span)
Electrical protection
Short-circuit protection Reverse polarity protection Electromagnetic compatibility Option Ex-protection only with 2-wire DX13-DMK permanent damage, also function emission immunity according 61326 zone zone 85°C safety technical maximum values: 1nF,
Mechanical stability
Vibration Shock 2000
Permissible temperatures
Medium Electronics environment Storage Ex-protection: application zone application zone higher:
pressure ranges possible with mechanical connection G1/2" flush vacuum nominal pressure max. medium temperature accuracy according 60770 limit point adjustment (non-linearity, hysteresis, repeatability) optional cooling element influence thermal effects offset span depending installation position filling conditions approved atmospheric pressure from with optional cooling element maximum permissible temperature valid
pressure measurement
Flush Pressure Transmitter
Technical Data
Mechanical connection
Standard
Connector 43650
Optional
Connector 43650 Connector 43650
flush diaphragm
flush diaphragm
flush diaphragm
G1/2" flush (DIN 3852)
G3/4" flush (DIN 3852)
flush (DIN 3852)
with cooling element
Ex-protection: total length increases 26.5mm!
Electrical connection
Standard Optional
43650
Binder Series
M12x1 4-pin
Cable gland
x1.5 (for cable-
Cable outlet
Buccaneer
Field housing
max. different cable types lengths available standard: cable without ventilation tube, optionally cable with ventilation tube gauge pressure cable with ventilation tube required
Flush Pressure Transmitter
Technical Data
Filling Fluids
Standard Optional Silicon food compatible (with FDA-approval) Halocarbon others request
Materials
Pressure port Housing Seals (media wetted) Diaphragm Media wetted parts stainless steel 1.4571 (316Ti) stainless steel 1.4301 (304) field housing: 1.4305 (303), cable gland: brass, nickel plated
bar: bar: others request stainless steel 1.4435 (316L)
pressure port, seals, diagragm
Miscellaneous
Cable capacitance Cable inductance Current consumption Weight Installation position Operational life cable without tube: cable with tube: cable without tube: cable with tube: signal output current: signal output voltage: cycles signal line/shield: pF/m signal line/shield: pF/m signal line/shield: 0.65 µH/m signal line/shield: µH/m max. max. signal line/signal line: pF/m signal line/signal line: pF/m signal line/signal line: 0.65 µH/m signal line/signal line: µH/m
min. (depending process connection)
configuration
Electrical connection 2-wire-system Supply Supply Ground 3-wire-system Supply Supply Signal Ground 43650 ground ground Binder (5-pin) M12x1 (4-pin) Buccaneer (4-pin) Cable colours (DIN 47100) white brown yellow green (shield) white brown green yellow green (shield)
Wiring diagrams
2-wire-system (current)
3-wire-system (current)
3-wire-system (voltage)
electrical connection mounted cable factory Pressure transmitters calibrated vertical position with pressure connection down. this position changed installation there slight deviations zero point pressure ranges bar.
This data sheet contains product specification, properties guaranteed. Subject change without notice.

Other recent searches


Si6361DQ - Si6361DQ   Si6361DQ Datasheet
MURB1660CT - MURB1660CT   MURB1660CT Datasheet
KBL005-10 - KBL005-10   KBL005-10 Datasheet
HUF76409D3 - HUF76409D3   HUF76409D3 Datasheet
HUF76409D3S - HUF76409D3S   HUF76409D3S Datasheet
GSM850 - GSM850   GSM850 Datasheet
DCS1800 - DCS1800   DCS1800 Datasheet
1900 - 1900   1900 Datasheet
SA1137-002 - SA1137-002   SA1137-002 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive