| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
March 2006, MegaCore Function Version 1.0.1 This document address
Top Searches for this datasheetSerialLite MegaCore Function March 2006, MegaCore Function Version 1.0.1 This document addresses known errata documentation issues SerialLite MegaCore® function version 1.0.1. Errata functional defects errors, which cause SerialLite MegaCore function deviate from published specifications. Documentation issues include errors, unclear descriptions, omissions from current published specifications product documents. Table shows issues that affect SerialLite MegaCore function v1.0.1. Table SerialLite MegaCore Function v1.0.1 Issues Section Configuration Issue Retry-On-Error Parameter Does Function Expected Missing Start Packet Missing Packet Errors Cyclic Redundancy Code Checking (CRC) Cannot Enabled Some Configurations Page Device Support Some Configurations Operational Stratix Devices Some Configurations Operational Stratix Devices most up-to-date errata this release, refer errata sheet Altera® website: Configuration This section describes configuration issues. Retry-On-Error Parameter Does Function Expected When retry-on-error parameter turned segments that contain errors supposed acknowledged NACK segments starting from segment with errors expected retransmitted. However, v1.0.1 release, retry-on-error feature does acknowledge errored packet with NACK. Altera Corporation ES-SRLTII05-1.1 Configuration Affected Configurations This issue affects variations MegaCore function that retry-on-error parameter. Design Impact Packets with errors cause MegaCore function timeout, error continues link goes down after four cycles. Workaround Turn retry-on-error parameter. Solution Status This issue will fixed next release SerialLite MegaCore function. Missing Start Packet Missing Packet Errors receiver Atlantic monitors report missing start packet (MSOP) missing packet (MEOP) errors. clock compensation removal block inserts IDLEs unexpected locations (causes protocol violations) when recovered clock's (rcvd_clk_out) frequency slower than transmit reference clock's (trefclk) frequency. Affected Configurations This issue affects variations MegaCore function that have clock compensation enabled (enable frequency offset tolerance parameter turned on). Design Impact clock compensation removal block underflows, causing IDLE inserted locations that violate SerialLite protocol. example, between address (ADR) single lane variations between CRC. Workaround Turn enable frequency offset tolerance parameter. SerialLite MegaCore Function v1.0.1 Altera Corporation Device Support Solution Status This issue will fixed next release SerialLite MegaCore function. Cyclic Redundancy Code Checking (CRC) Cannot Enabled Some Configurations checking generation never enabled when transfer size equal number lanes transmitter receiver equal Affected Configurations This issue affects variations MegaCore function that have transfer size only lane transmitter receiver. Design Impact checking generation nonfunctional. Packets passed normally, other functionality unaffected. However, should data error occur, MegaCore function only detect error results 8B/10B data error (disparity, length violation, invalid control word). Workaround There workaround. Solution Status This issue will fixed next release SerialLite MegaCore function. Device Support This section describes device support issues. Some Configurations Operational Stratix Devices Some SerialLite MegaCore function configurations supported this release because preliminary model compiler support Stratix® devices. simulation model compiler support mature, these configurations will operational. Altera Corporation SerialLite MegaCore Function v1.0.1 Device Support Affected Configurations This issue affects configurations using data rates greater than 3.125 Gbps, using following modes: Unidirectional Asymmetric Broadcast transmitter only receiver only Design Impact Only symmetrical mode (including broadcast) with data rates below 3.125 Gbps operational this release SerialLite MegaCore function. Workaround There workaround. Solution Status This issue will fixed future release Quartus® software SerialLite MegaCore function. Some Configurations Operational Stratix Devices Some SerialLite MegaCore function configurations supported this release because model support Stratix devices. simulation model support matures, these configurations will operational. Affected Configurations This issue affects following configurations: Unidirectional mode Asymmetric mode Broadcast transmitter only receiver only mode Design Impact Only symmetrical mode (including broadcast) operational this release SerialLite MegaCore function. Workaround There workaround. SerialLite MegaCore Function v1.0.1 Altera Corporation Contact Information Solution Status This issue been fixed Quartus software version service pack Contact Information Revision History more information, contact Altera's mySupport website www.altera.com/mysupport click Create Service Request. Choose Product Related Request form. Table shows revision history SerialLite MegaCore Function v1.0.1 Errata Sheet. Table SerialLite MegaCore Function v1.0.1 Errata Sheet Revision History Version Date March 2006 Errata Summary Added following issues: "The Retry-On-Error Parameter Does Function Expected" page "Missing Start Packet Missing Packet Errors" page Modified following issue: "Some Configurations Operational Stratix Devices" page "Some Configurations Operational Stratix Devices" page First release. December 2005 Innovation Drive Jose, 95134 (408) 544-7000 www.altera.com Applications Hotline: (800) 800-EPLD Literature Services: literature@altera.com Copyright 2006 Altera Corporation. rights reserved. Altera, Programmable Solutions Company, stylized Altera logo, specific device designations, other words logos that identified trademarks and/or service marks are, unless noted otherwise, trademarks service marks Altera Corporation U.S. other countries. other product service names property their respective holders. Altera products protected under numerous U.S. foreign patents pending applications, maskwork rights, copyrights. Altera warrants performance semiconductor products current specifications accordance with Altera's standard warranty, reserves right make changes products services time without notice. Altera assumes responsibility liability arising application information, product, service described herein except expressly agreed writing Altera Corporation. Altera customers advised obtain latest version device specifications before relying published information before placing orders products services. Altera Corporation SerialLite MegaCore Function v1.0.1 Other recent searchesUCC1807-1 - UCC1807-1 UCC1807-1 Datasheet UCC2807-1 - UCC2807-1 UCC2807-1 Datasheet UCC3807-1 - UCC3807-1 UCC3807-1 Datasheet TPA6017A2 - TPA6017A2 TPA6017A2 Datasheet SV3613 - SV3613 SV3613 Datasheet M32R - M32R M32R Datasheet FR201G - FR201G FR201G Datasheet FR207G - FR207G FR207G Datasheet 1795320000 - 1795320000 1795320000 Datasheet
Privacy Policy | Disclaimer |