K3MA-F Highly Visible Display with 2-color (Red Green) LEDs


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Frequency/Rate Meter
K3MA-F
Highly Visible Display with 2-color (Red Green) LEDs
Contact, NPN, PNP, voltage pulse input. Front-panel operation easy setting. Average processing function suppresses flicker. Includes scaling, auto-zero time, startup compensation time functions. Easy confirmation max/min display. Short 80-mm depth (measured from edge face plate). Finger protective cover (standard equipment) guards against electric shock. Water- dust-proof NEMA4X (IP66 equivalent) front panel. Recognized U.S. Canadian requirements under Component Recognition Program marking. Built-in external power supply VDC, mA).
Model Number Structure
Model Number Legend
K3MA-F-@
Supply Voltage 100-240VAC: 24VAC/VDC: VAC/VDC Input Type Rotary pulse Output Type None: output relay contact outputs (SPST-NO)
Ordering Information
List Models
Input type Rotary pulse Supply voltage VAC/VDC None relay contact outputs (SPST-NO) None relay contact outputs (SPST-NO) Output Model K3MA-F 100-240VAC K3MA-F-A2 100-240VAC K3MA-F 24VAC/VDC K3MA-F-A2 24VAC/VDC
Rubber Packing
Model K32-P1 Note: Rubber packing provided with Controller.
Accessories (Order Separately)
Name Splash-proof Soft Cover Shape K32-49SC Model
Hard Cover
K32-49HC
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Specifications
Ratings
Model Supply voltage Operating voltage range Power consumption (under maximum load) External power supply Insulation resistance Dielectric strength Noise immunity K3MA-F 100-240VDC, K3MA-F-A2 100-240VAC 110% rated supply voltage max. VDC, min. VDC) between external terminal case. Insulation provided between inputs, outputs, power supply. 2,000 between external terminal case. Insulation provided between inputs, outputs, power supply. ±1,500 power supply terminals normal com- ±480 power supply terminals normal mode. mode. ±1,500 common mode. square-wave noise with square-wave noise with Vibration: Acceleration: m/s2 each directions sweeps. m/s2 (100 m/s2 relay contact outputs) times each axes, directions. Operating: -10°C 55°C (with condensation icing) Storage: -25°C 65°C (with condensation icing) UL3121-1, conforms EN61010-1 (IEC61010-1) (Pollution degree 2/overvoltage category Conforms VDE0106/P100 (finger protection) (EMI) Emission Enclosure: Emission Mains: (EMS) Immunity ESD: EN61326+A1 Industry CISPR Group class CISRP16-1/-2 CISPR Group class CISRP16-1/-2 EN61326+A1 Industry EN61000-4-2: contact discharge discharge Immunity RF-interference: EN61000-4-3: (amplitude-modulated, GHz) Electrical Fast Transient Noise: EN61000-4-4: (power line) Immunity Burst Noise: line line (I/O signal line) Immunity Surge: EN61000-4-5: (power line) line ground (power line) Immunity Conducted Disturbance: EN61000-4-6: (0.15 MHz) Immunity Voltage Dip/Interrupting: EN61000-4-11: cycle, 180°, 100% (rated voltage) Approx. max. VAC) max. VDC) K3MA-F 24VAC/VDC, K3MA-F-A2 24VAC/VDC VAC/VDC
Vibration resistance Shock resistance Ambient temperature Approved safety standards
Weight
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Characteristics
Input signal No-voltage contact max., ON/OFF pulse width: min.) Voltage pulse max., ON/OFF pulse width: min., voltage: V/OFF voltage: Open collector max., ON/OFF pulse width min.) Connectable Sensors residual voltage: max. leakage current: max. Load current: Must have switching capacity min. Must able dependably switch load current max. ±0.1%FS digit 23±5°C) Cycle measurement digits (-19999 99999) 7-segment digital display, Character height: 14.2 displayed automatically with negative input signal. Leading zeros displayed. Programmable with front-panel inputs (range display: -19999 99999). decimal point position desired. hold (maximum value), hold (minimum value) Programmable with front-panel inputs (0001 9999). Scaling teach function Display color change (green (red), green, (green), red) type change (upper limit, lower limit, upper/lower limit) Average processing (simple average OFF/2/4/8 operations) Auto-zero time Startup compensation time Setting change lockout Parameter initialization Display auto-return time Relays: SPST-NO max. Front panel: NEMA4X indoor (equivalent IP66) Rear case: standard IP20 Terminals: standard IP00 finger protection (VDE0106/100) Non-volatile memory (EEPROM) (possible rewrite 100,000 times)
Measuring accuracy Measurement method Max. displayed digits Display Polarity display Zero display Scaling function Hold function Hysteresis setting Other functions
Output Delay comparative outputs Degree protection
Memory protection
Measuring Ranges
No-voltage Contact/Open Collector Inputs
Input No-voltage contact max.) with ON/OFF pulse width min. Open collector max.) with ON/OFF pulse width min. Measuring range 0.05 30.00 Measuring accuracy ±0.1% digit max. 23±5°C) Displayable range -19999 99999 (with scaling function)
Input/Output Ratings
Relay Contact Output
Item Rated load ratings) Rated carry current Max. contact voltage Max. contact current Max. switching capacity Min. permissible load level, reference value) Mechanical life Electrical life ambient temperature 20°C) Resistive load (cos VAC, max. terminal) VAC, terminal) 1,250 5,000,000 times min. switching frequency 1,200 times/min) 100,000 times min. rated load switching frequency times/min) Inductive load (cos 0.4, VAC,
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Connections
Terminal Arrangement
Power supply
Output terminals 100- 240-VAC type 24-VAC/VDC type Input terminals polarity 24-VDC connection.)
Models with comparative output OUT1 OUT2
External power supply
Note: Refer Input Circuits page
Terminal
Name Operation power Pulse input Outputs External power supply
Description Connects operation power supply. No-voltage contact/open collector input Outputs relay outputs. power supply sensors.
Block Diagram
Input Input circuit Microcomputer
Display Output circuit Contact output (See note.)
Constant voltage circuit
Power supply circuit
Note: Relay output models only.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Input Circuits
Pulse Input
NPN, contact input Pulse detection circuit
Voltage detection circuit
PNP, voltage pulse input Voltage pulse
negative pole sensor power supply connected internally.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Operation
Main Functions
Input Types Ranges
Frequency range (setting parameter) Pulse frequency selection (p-fre) Function Selects pulse input signal. Input range (setting parameters) 0.05 30.00 (30) (5k) Setting range Displayable from -19999 99999 with scaling function. position decimal point desired.
Pulse Frequency Selection
Parameter p-fre Note: default value (5k)." Setting value Meaning 0.05 30.00 measurement range measurement range
Scaling
When desired display value corresponding input, value will displayed line between points determining zero point. Parameter Setting value 99999 -19999 99999 Meaning Input value Display value Parameter Setting value %.%%%% %%.%%% %%%.%% %%%%.% %%%%%
Note: Display value DISPLAY
Meaning Display four digits after decimal point Display three digits after decimal point Display digits after decimal point Display digit after decimal point decimal point
initial value will change depending pulse frequency selection. decimal point optionally displayed. When displaying decimal point, consider number digits follow decimal point prior setting scaling display value. p-fre initial setting decimal display will 000.00.
INPUT
Input value
Teaching with actual values possible. Instead setting inputting with Shift Key, current values input scaling input values teaching. This useful making settings while checking operation status K3MA-F.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Convenient Functions
Scaling Teach parameter (inp) K3MA-F's initial setting level using actual input values with teaching function. After displaying parameter, actual input settings made with following operation.
Teaching mode
Monitor mode
flashes. register shift monitor mode.
shift next parameter without registering.
lights indicate that parameter valid teaching.
Normal change
turns OFF.
Next parameter
Types (Comparative Output Models Only)
operate three following modes accordance with compared values: Upper limit (High Acting): output turned when measurement value greater than value. Lower limit (Low Acting): output turned when measurement value less than value. Upper lower limits (Outside Band Acting): upper limit value) lower limit value) independently. output turned when measurement value greater than upper-limit value less than lower-limit value. Parameter out1.t out2.t value hi-lo Meaning Upper limit: Upper-limit alarm operation Lower limit: Lower-limit alarm operation Upper lower limits: Upperand lower limit alarm operation
Upper Limit (High Acting)
Lower Limit (Low Acting)
Upper Lower Limits (Outside Band Acting)
OUT1 upper-limit value Measurement value Hysteresis Hysteresis
OUT1 value Measurement value
Hysteresis Measurement value OUT1 value Hysteresis
Output
Output
OUT1 lower-limit value Output
three types output operations shown above combined desired. following examples possible combinations.
Upper Limit 2-stage Output
Threshold Output
OUT2 upper-limit value
Combination Upper Limit Upper/Lower Limits
Measurement value OUT2 upper-limit value OUT1 value Measurement value OUT2 lower-limit value
OUT2 value Measurement value OUT1 value
OUT1 upper-limit value OUT1 lower-limit value OUT2 lower-limit value
OUT2 OUT1
OUT2 OUT1
OUT2 OUT1
Parameter Initialization
This function returns parameters their initial values. Parameter init Setting value -Initializes parameters. Meaning
this reset K3MA-F after returning factory-set condition.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Average Processing
Average processing stabilizes display minimizing pulsating flicker caused fluctuations pulse width sensor input eccentricity rotating shafts.
Changing Display Color
color value displayed either green. comparative output models, display color change from green red, from green, according status comparison criterion.
113.36
OUT1 value Green
100.05
Hysteresis (Comparative Output Models Only)
hysteresis comparative outputs prevent chattering output when measurement value fluctuates finely near value.
OUT2 value
8.781
Display Auto-return Time
This function automatically returns display operation level's current value keys pressed preset time (called display auto-return time).
Upper limit (high acting)
value
Hysteresis
Measurement value
Move-to-Protect-Level Time
time required shift protect level desired.
Output
MAX/MIN Display
maximum minimum measurement (display) values from time power turned until current time stored displayed. This useful, example, when measuring maximum value.
Current value
Auto-zero Time
This function sets time display return zero when input pulses stop. time longer than expected input pulse cycle (the interval between input pulse next). Proper measurement possible time shorter than input pulse cycle. Setting range 19.9
MAX/MIN
MAX/MIN LEVEL MODE SHIFT
Startup Compensation Time
startup compensation time time wait measurement operation entered after power supply K3MA-F turned this parameter cancel measurement comparative output operation until rotating body reaches normal speed when power supply K3MA-F rotating body turned same time.
Display
value
MAX/MIN
MAX/MIN LEVEL MODE SHIFT
value
MAX/MIN
MAX/MIN LEVEL MODE SHIFT
Lower limit setting (OUT2)
Startup compensation time
00000 displayed Power supply OUT2 output
Time
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Nomenclature
Operation indicators
Main indicator
Level indicator
MAX/MIN
LEVEL
MODE
SHIFT
MAX/MIN Level
Name Main indicator Opera- tion indica- tors Level indicator MAX/MIN Level Mode Shift Level indicator when output when output when value being displayed changed. when main indicator showing value. when main indicator showing value.
Mode Shift
Functions
Displays current values, parameter names (abbreviations), comparative value settings.
when teaching function operable. Blinks while teaching function operating. Displays current level that K3MA-F (See below details.) Used display values when measurement value being displayed. Used change level. level switched between operation level initial setting level. Used allow main indicator indicate parameters sequentially. Used enable value changed. When changing value, this used move along digits. Used change value. Used clear forced-zero function when measurement value being displayed. Level Protect Operation Initial setting Advanced function setting
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Dimensions
101.2 Terminal cover (provided)
Main indicator character size
14.2
Panel cut-out
min.
MAX/MIN
LEVEL
MODE
SHIFT
Application Examples
Displaying conveyor belt feed speed
K3MA-F
m/min
Monitoring rotations Displaying monitor mixer churner output from inverter rotations line speed
Inverter
Gear Proximity sensor
Monitoring line speed reflow furnace Displaying feed speed food processing, conveying, sintering
Mixers resin molding Powdering/pelleting machines, centrifugal separators
http://www.ia.omron.com/
min.
92+0.5
45+0.5
44.8
K3MA-F uses terminals. terminal cover provided.
K3MA-F K3MA-F
Mixer churner
Motor
Voltage pulse
Note: monitor output from inverter analog, such K3MA-J.
Monitoring conveyor speed Machining equipment (grinders, polishers)
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Installation
Insert K3MA-F into panel cut-out hole. waterproof installation, insert rubber gasket onto body K3MA-F.
Wiring
following crimp terminals.
max.
max.
Unit Labels (Provided)
unit labels attached K3MA-F. Select desired labels from provided sheet.
adaptor into grooves left right sides rear case, then push until contacts panel secure K3MA-F.
Note: scales gauges, unit labels that specified relevant laws regulations.
Angle View
K3MA designed provide best visibility angles shown following diagram.
Rubber Packing (Sold Separately)
K32-P1
rubber packing lost damaged, ordered using following model number K32-P1. (Depending operating environment, deterioration, contraction, hardening rubber packing occur order ensure level waterproofing specified NEMA4, periodic replacement recommended. Note:Ruber packing provided with Controller.
Wiring Precautions
crimp terminals. Tighten terminal screws torque approximately avoid influence noise, route signal lines power lines separately.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Operating Procedures
Operations Mode
Checking Maximum Minimum Values
maximum minimum values displayed pressing MAX/MIN while measurement being displayed.
Measurement value
MAX/MIN
value
MAX/MIN
value
MAX/MIN
maximum minimum values reset pressing MAX/MIN min. when maximum minimum value displayed.
Checking Setting Comparative Values (for Models with Comparative Output Function)
Each time Mode pressed when measurement value, maximum value, minimum value displayed, comparative values will displayed following order: OUT1 value OUT1 upper-limit value, OUT1 lower-limit value OUT2 upper-limit value, OUT2 lower limit value
Measurement value value value
OUT1 value
OUT2 value
OUT1 upperlimit value
OUT1 lowerlimit value
OUT2 upperlimit value
OUT2 lowerlimit value
Note: When comparative value displayed, changed pressing Shift (when protection OFF).
Levels
"Level" refers grouping parameters. following table lists operations that possible each levels, diagram tells move between levels. There some parameters that displayed certain models. Level name Protect Operation Initial setting Advanced function setting Setting lockouts. Displaying current values, setting values. Function Continue Continue Measurement
Making initial settings input type, scaling, output operating action, Stopped other parameters. Setting average processing, display color settings, other advanced function parameters. Stopped
Power
Level MODE least user-set time
Operation level
Level MODE min. Level min. Level min.
Protect level
Measurement progress
Initial setting level
Measurement stopped Level change
Level min.
Password input
Advanced function setting level
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Parameters
Note: Some parameters displayed certain models. K3MA-F will stop measurement level changed initial setting level advanced-function setting level. input range changed, some parameters default values. Therefore, input range first. Settings displayed reversed colors defaults.
Power
Operation level
Current value
models with comparative output function. MODE
OUT1 value
these.
MODE
OUT1 upper-limit value
MODE
OUT1 lower-limit value
MODE
OUT2 value
MODE
these.
OUT2 upper-limit value
MODE
OUT2 lower-limit value
MODE
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Press Level more than
Initial setting level
Press Level more than Pulse frequency MODE
Scaling input value
Press Level
less than
Advanced-function setting level
Pulse frequency
Enter password "-0169"
MODE Scaling
Parameter initialization
Unit: times Comparative hysteresis
Average processing
MODE Models with comparative output function
OUT1 hysteresis
MODE
Scaling display value
MODE
OUT2 hysteresis
MODE
Decimal point position
MODE
Auto-zero time
MODE
OUT1 type
Upper Limit Lower Limit
MODE
Startup compensation time
Models with comparative output function
MODE
OUT2 type
Upper/Lower Limits
MODE
Upper Limit Lower Limit Upper/Lower Limits Green (red)
Display color change
Green (green)
MODE
Move advancedfunction setting level
MODE
Display auto-return time
MODE
MODE
Move-toprotectlevel time
Unit:
MODE
Unit:
Settings displayed reversed colors initial settings.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Press Operation level Press Level than preset time. Mode more Level Mode more than
Protect level
Operation/adjustment lockouts
MODE
Setting level lockouts
MODE
Setting change lockout
MODE
Operation/Adjustment Lockouts
Restricts operations operation level adjustment level. Parameter Setting Operation level Current value display oapt Allowed Allowed Allowed value display Allowed Allowed Prohibited
Initial Settings
Power
Press Level level.
min. move initial setting
Initial setting This displayed models with comparative output function.
Select pulse frequency measurement. scaling values type required.
Setting Level Lockouts
Restricts shifting initial setting level advanced function setting level. Parameter Setting Shift initial setting level Shift advanced function setting level Allowed Prohibited Prohibited
Press Level operation level. more than second return
required, shift advanced-function setting level number measurements average processing, hysteresis values, auto-zero time, startup compensation time, display color change, display auto-return time, move-toprotect-level time.
icpt
Allowed Allowed Prohibited
Setting Change Lockout
Restricts setting changes operation. When this lockout set, longer possible shift setting change mode. Parameter wtpt Setting Setting change operation Allowed Prohibited
Measurement starts. Specify value
However, protect level parameters still changed.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
K3MA-F
Setting Example
Initial Settings
settings following example shown here. When displaying flowrate (e.g., l/min l/h), make scaling settings after confirming characteristics flowrate sensor. There flowrate sensors that output analog signals. this kind flowrate sensor used, consider using K3MA-J. Select maximum input frequency K3MA-F. pulse frequency selection either kHz. example, this because conveyor belt turning slow speed. Parameter: p-fre (pulse frequency), Setting value: scaling. relationship between display value input value shown following equation. Rotations (rpm) Frequency input/No. pulses rotation Cycle speed (m/min) Rotations roll circumference pulses rotation Frequency (Hz) Roller diameter When input conditions applied this equation, obtain following: Display value input display value 18.8495 (m/min). scaling settings K3MA-F must integers. Also, decrease error, scaling value multiplied 1,000, obtain input 1000 display value 18850. However, because display value this case displayed first decimal place, scaling shown following example that 18850 displayed input Parameter Setting value (scaling input value) (scaling display value) 18850 (decimal point position) %%%%.%
Input value
Example: Display conveyor belt feed speed
E2E-X5E1 Proximity Sensor
MAX/MIN
LEVEL
MODE
SHIFT
K3MA-F-A2 100-240VAC
Here, conveyor belt feed speed displayed units m/min. Proximity Sensor: E2E-X5E1, output
pulse/rotation, roller diameter Display value
18850
Note: decimal point position here refers position number after scaling. When setting scaling display value, necessary consider number digits displayed past decimal point.
Troubleshooting
When error occurs, error details will displayed main indicator. Confirm error from main indicator take appropriate countermeasures. Level display Main indicator e111 e111 Error contents memory error EEPROM memory error Countermeasures Repair necessary. Consult your OMRON sales representative. When this error displayed, press Level seconds, settings will restored factory settings. error cannot recovered, repair necessary. Consult your OMRON sales representative. Promptly change input value that falls within specified range. scaling value inappropriate. Review scaling value initial setting level. Flashes -19999 scaling display value lower than -19999. Promptly change input value that falls within specified range. scaling value inappropriate. Review scaling value initial setting level.
Flashes 99999
scaling display value exceeds 99999.
DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. interest product improvement, specifications subject change without notice.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 Rights Reserved.
Read Understand This Catalog
Please read understand this catalog before purchasing products. Please consult your OMRON representative have questions comments.
Warranty Limitations Liability
WARRANTY
OMRON's exclusive warranty that products free from defects materials workmanship period year other period specified) from date sale OMRON. OMRON MAKES WARRANTY REPRESENTATION, EXPRESS IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, FITNESS PARTICULAR PURPOSE PRODUCTS. BUYER USER ACKNOWLEDGES THAT BUYER USER ALONE DETERMINED THAT PRODUCTS WILL SUITABLY MEET REQUIREMENTS THEIR INTENDED USE. OMRON DISCLAIMS OTHER WARRANTIES, EXPRESS IMPLIED.
LIMITATIONS LIABILITY
OMRON SHALL RESPONSIBLE SPECIAL, INDIRECT, CONSEQUENTIAL DAMAGES, LOSS PROFITS, COMMERCIAL LOSS CONNECTED WITH PRODUCTS, WHETHER SUCH CLAIM BASED CONTRACT, WARRANTY, NEGLIGENCE, STRICT LIABILITY. event shall responsibility OMRON exceed individual price product which liability asserted. EVENT SHALL OMRON RESPONSIBLE WARRANTY, REPAIR, OTHER CLAIMS REGARDING PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, MAINTAINED SUBJECT CONTAMINATION, ABUSE, MISUSE, INAPPROPRIATE MODIFICATION REPAIR.
Application Considerations
SUITABILITY
OMRON shall responsible conformity with standards, codes, regulations that apply combination products customer's application product. customer's request, OMRON will provide applicable third party certification documents identifying ratings limitations that apply products. This information itself sufficient complete determination suitability products combination with product, machine, system, other application use. following some examples applications which particular attention must given. This intended exhaustive list possible uses products, intended imply that uses listed suitable products: Outdoor use, uses involving potential chemical contamination electrical interference, conditions uses described this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, installations subject separate industry government regulations. Systems, machines, equipment that could present risk life property. Please know observe prohibitions applicable products. NEVER PRODUCTS APPLICATION INVOLVING SERIOUS RISK LIFE PROPERTY WITHOUT ENSURING THAT SYSTEM WHOLE BEEN DESIGNED ADDRESS RISKS, THAT OMRON PRODUCT PROPERLY RATED INSTALLED INTENDED WITHIN OVERALL EQUIPMENT SYSTEM.
Disclaimers
CHANGE SPECIFICATIONS
Product specifications accessories changed time based improvements other reasons. practice change model numbers when published ratings features changed, when significant construction changes made. However, some specifications product changed without notice. When doubt, special model numbers assigned establish specifications your application your request. Please consult with your OMRON representative time confirm actual specifications purchased product.
DIMENSIONS WEIGHTS
Dimensions weights nominal used manufacturing purposes, even when tolerances shown.
ERRORS OMISSIONS
information this catalog been carefully checked believed accurate; however, responsibility assumed clerical, typographical, proofreading errors, omissions.
PERFORMANCE DATA
Performance data given this catalog provided guide user determining suitability does constitute warranty. represent result OMRON's test conditions, users must correlate actual application requirements. Actual performance subject OMRON Warranty Limitations Liability.
PROGRAMMABLE PRODUCTS
OMRON shall responsible user's programming programmable product, consequence thereof.
COPYRIGHT COPY PERMISSION
This catalog shall copied sales promotions without permission. This catalog protected copyright intended solely conjunction with product. Please notify before copying reproducing this catalog manner, other purpose. copying transmitting this catalog another, please copy transmit entirety.
2007.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
interest product improvement, specifications subject change without notice.
(c)Copyright OMRON Corporation 2007 Rights Reserved.