| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
K3MA-F Highly Visible Display with 2-color (Red Green) LEDs
Top Searches for this datasheetFrequency/Rate Meter K3MA-F Highly Visible Display with 2-color (Red Green) LEDs Contact, NPN, PNP, voltage pulse input. Front-panel operation easy setting. Average processing function suppresses flicker. Includes scaling, auto-zero time, startup compensation time functions. Easy confirmation max/min display. Short 80-mm depth (measured from edge face plate). Finger protective cover (standard equipment) guards against electric shock. Water- dust-proof NEMA4X (IP66 equivalent) front panel. Recognized U.S. Canadian requirements under Component Recognition Program marking. Built-in external power supply VDC, mA). Model Number Structure Model Number Legend K3MA-F-@ Supply Voltage 100-240VAC: 24VAC/VDC: VAC/VDC Input Type Rotary pulse Output Type None: output relay contact outputs (SPST-NO) Ordering Information List Models Input type Rotary pulse Supply voltage VAC/VDC None relay contact outputs (SPST-NO) None relay contact outputs (SPST-NO) Output Model K3MA-F 100-240VAC K3MA-F-A2 100-240VAC K3MA-F 24VAC/VDC K3MA-F-A2 24VAC/VDC Rubber Packing Model K32-P1 Note: Rubber packing provided with Controller. Accessories (Order Separately) Name Splash-proof Soft Cover Shape K32-49SC Model Hard Cover K32-49HC http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Specifications Ratings Model Supply voltage Operating voltage range Power consumption (under maximum load) External power supply Insulation resistance Dielectric strength Noise immunity K3MA-F 100-240VDC, K3MA-F-A2 100-240VAC 110% rated supply voltage max. VDC, min. VDC) between external terminal case. Insulation provided between inputs, outputs, power supply. 2,000 between external terminal case. Insulation provided between inputs, outputs, power supply. ±1,500 power supply terminals normal com- ±480 power supply terminals normal mode. mode. ±1,500 common mode. square-wave noise with square-wave noise with Vibration: Acceleration: m/s2 each directions sweeps. m/s2 (100 m/s2 relay contact outputs) times each axes, directions. Operating: -10°C 55°C (with condensation icing) Storage: -25°C 65°C (with condensation icing) UL3121-1, conforms EN61010-1 (IEC61010-1) (Pollution degree 2/overvoltage category Conforms VDE0106/P100 (finger protection) (EMI) Emission Enclosure: Emission Mains: (EMS) Immunity ESD: EN61326+A1 Industry CISPR Group class CISRP16-1/-2 CISPR Group class CISRP16-1/-2 EN61326+A1 Industry EN61000-4-2: contact discharge discharge Immunity RF-interference: EN61000-4-3: (amplitude-modulated, GHz) Electrical Fast Transient Noise: EN61000-4-4: (power line) Immunity Burst Noise: line line (I/O signal line) Immunity Surge: EN61000-4-5: (power line) line ground (power line) Immunity Conducted Disturbance: EN61000-4-6: (0.15 MHz) Immunity Voltage Dip/Interrupting: EN61000-4-11: cycle, 180°, 100% (rated voltage) Approx. max. VAC) max. VDC) K3MA-F 24VAC/VDC, K3MA-F-A2 24VAC/VDC VAC/VDC Vibration resistance Shock resistance Ambient temperature Approved safety standards Weight http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Characteristics Input signal No-voltage contact max., ON/OFF pulse width: min.) Voltage pulse max., ON/OFF pulse width: min., voltage: V/OFF voltage: Open collector max., ON/OFF pulse width min.) Connectable Sensors residual voltage: max. leakage current: max. Load current: Must have switching capacity min. Must able dependably switch load current max. ±0.1%FS digit 23±5°C) Cycle measurement digits (-19999 99999) 7-segment digital display, Character height: 14.2 displayed automatically with negative input signal. Leading zeros displayed. Programmable with front-panel inputs (range display: -19999 99999). decimal point position desired. hold (maximum value), hold (minimum value) Programmable with front-panel inputs (0001 9999). Scaling teach function Display color change (green (red), green, (green), red) type change (upper limit, lower limit, upper/lower limit) Average processing (simple average OFF/2/4/8 operations) Auto-zero time Startup compensation time Setting change lockout Parameter initialization Display auto-return time Relays: SPST-NO max. Front panel: NEMA4X indoor (equivalent IP66) Rear case: standard IP20 Terminals: standard IP00 finger protection (VDE0106/100) Non-volatile memory (EEPROM) (possible rewrite 100,000 times) Measuring accuracy Measurement method Max. displayed digits Display Polarity display Zero display Scaling function Hold function Hysteresis setting Other functions Output Delay comparative outputs Degree protection Memory protection Measuring Ranges No-voltage Contact/Open Collector Inputs Input No-voltage contact max.) with ON/OFF pulse width min. Open collector max.) with ON/OFF pulse width min. Measuring range 0.05 30.00 Measuring accuracy ±0.1% digit max. 23±5°C) Displayable range -19999 99999 (with scaling function) Input/Output Ratings Relay Contact Output Item Rated load ratings) Rated carry current Max. contact voltage Max. contact current Max. switching capacity Min. permissible load level, reference value) Mechanical life Electrical life ambient temperature 20°C) Resistive load (cos VAC, max. terminal) VAC, terminal) 1,250 5,000,000 times min. switching frequency 1,200 times/min) 100,000 times min. rated load switching frequency times/min) Inductive load (cos 0.4, VAC, http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Connections Terminal Arrangement Power supply Output terminals 100- 240-VAC type 24-VAC/VDC type Input terminals polarity 24-VDC connection.) Models with comparative output OUT1 OUT2 External power supply Note: Refer Input Circuits page Terminal Name Operation power Pulse input Outputs External power supply Description Connects operation power supply. No-voltage contact/open collector input Outputs relay outputs. power supply sensors. Block Diagram Input Input circuit Microcomputer Display Output circuit Contact output (See note.) Constant voltage circuit Power supply circuit Note: Relay output models only. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Input Circuits Pulse Input NPN, contact input Pulse detection circuit Voltage detection circuit PNP, voltage pulse input Voltage pulse negative pole sensor power supply connected internally. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Operation Main Functions Input Types Ranges Frequency range (setting parameter) Pulse frequency selection (p-fre) Function Selects pulse input signal. Input range (setting parameters) 0.05 30.00 (30) (5k) Setting range Displayable from -19999 99999 with scaling function. position decimal point desired. Pulse Frequency Selection Parameter p-fre Note: default value (5k)." Setting value Meaning 0.05 30.00 measurement range measurement range Scaling When desired display value corresponding input, value will displayed line between points determining zero point. Parameter Setting value 99999 -19999 99999 Meaning Input value Display value Parameter Setting value %.%%%% %%.%%% %%%.%% %%%%.% %%%%% Note: Display value DISPLAY Meaning Display four digits after decimal point Display three digits after decimal point Display digits after decimal point Display digit after decimal point decimal point initial value will change depending pulse frequency selection. decimal point optionally displayed. When displaying decimal point, consider number digits follow decimal point prior setting scaling display value. p-fre initial setting decimal display will 000.00. INPUT Input value Teaching with actual values possible. Instead setting inputting with Shift Key, current values input scaling input values teaching. This useful making settings while checking operation status K3MA-F. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Convenient Functions Scaling Teach parameter (inp) K3MA-F's initial setting level using actual input values with teaching function. After displaying parameter, actual input settings made with following operation. Teaching mode Monitor mode flashes. register shift monitor mode. shift next parameter without registering. lights indicate that parameter valid teaching. Normal change turns OFF. Next parameter Types (Comparative Output Models Only) operate three following modes accordance with compared values: Upper limit (High Acting): output turned when measurement value greater than value. Lower limit (Low Acting): output turned when measurement value less than value. Upper lower limits (Outside Band Acting): upper limit value) lower limit value) independently. output turned when measurement value greater than upper-limit value less than lower-limit value. Parameter out1.t out2.t value hi-lo Meaning Upper limit: Upper-limit alarm operation Lower limit: Lower-limit alarm operation Upper lower limits: Upperand lower limit alarm operation Upper Limit (High Acting) Lower Limit (Low Acting) Upper Lower Limits (Outside Band Acting) OUT1 upper-limit value Measurement value Hysteresis Hysteresis OUT1 value Measurement value Hysteresis Measurement value OUT1 value Hysteresis Output Output OUT1 lower-limit value Output three types output operations shown above combined desired. following examples possible combinations. Upper Limit 2-stage Output Threshold Output OUT2 upper-limit value Combination Upper Limit Upper/Lower Limits Measurement value OUT2 upper-limit value OUT1 value Measurement value OUT2 lower-limit value OUT2 value Measurement value OUT1 value OUT1 upper-limit value OUT1 lower-limit value OUT2 lower-limit value OUT2 OUT1 OUT2 OUT1 OUT2 OUT1 Parameter Initialization This function returns parameters their initial values. Parameter init Setting value -Initializes parameters. Meaning this reset K3MA-F after returning factory-set condition. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Average Processing Average processing stabilizes display minimizing pulsating flicker caused fluctuations pulse width sensor input eccentricity rotating shafts. Changing Display Color color value displayed either green. comparative output models, display color change from green red, from green, according status comparison criterion. 113.36 OUT1 value Green 100.05 Hysteresis (Comparative Output Models Only) hysteresis comparative outputs prevent chattering output when measurement value fluctuates finely near value. OUT2 value 8.781 Display Auto-return Time This function automatically returns display operation level's current value keys pressed preset time (called display auto-return time). Upper limit (high acting) value Hysteresis Measurement value Move-to-Protect-Level Time time required shift protect level desired. Output MAX/MIN Display maximum minimum measurement (display) values from time power turned until current time stored displayed. This useful, example, when measuring maximum value. Current value Auto-zero Time This function sets time display return zero when input pulses stop. time longer than expected input pulse cycle (the interval between input pulse next). Proper measurement possible time shorter than input pulse cycle. Setting range 19.9 MAX/MIN MAX/MIN LEVEL MODE SHIFT Startup Compensation Time startup compensation time time wait measurement operation entered after power supply K3MA-F turned this parameter cancel measurement comparative output operation until rotating body reaches normal speed when power supply K3MA-F rotating body turned same time. Display value MAX/MIN MAX/MIN LEVEL MODE SHIFT value MAX/MIN MAX/MIN LEVEL MODE SHIFT Lower limit setting (OUT2) Startup compensation time 00000 displayed Power supply OUT2 output Time http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Nomenclature Operation indicators Main indicator Level indicator MAX/MIN LEVEL MODE SHIFT MAX/MIN Level Name Main indicator Opera- tion indica- tors Level indicator MAX/MIN Level Mode Shift Level indicator when output when output when value being displayed changed. when main indicator showing value. when main indicator showing value. Mode Shift Functions Displays current values, parameter names (abbreviations), comparative value settings. when teaching function operable. Blinks while teaching function operating. Displays current level that K3MA-F (See below details.) Used display values when measurement value being displayed. Used change level. level switched between operation level initial setting level. Used allow main indicator indicate parameters sequentially. Used enable value changed. When changing value, this used move along digits. Used change value. Used clear forced-zero function when measurement value being displayed. Level Protect Operation Initial setting Advanced function setting http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Dimensions 101.2 Terminal cover (provided) Main indicator character size 14.2 Panel cut-out min. MAX/MIN LEVEL MODE SHIFT Application Examples Displaying conveyor belt feed speed K3MA-F m/min Monitoring rotations Displaying monitor mixer churner output from inverter rotations line speed Inverter Gear Proximity sensor Monitoring line speed reflow furnace Displaying feed speed food processing, conveying, sintering Mixers resin molding Powdering/pelleting machines, centrifugal separators http://www.ia.omron.com/ min. 92+0.5 45+0.5 44.8 K3MA-F uses terminals. terminal cover provided. K3MA-F K3MA-F Mixer churner Motor Voltage pulse Note: monitor output from inverter analog, such K3MA-J. Monitoring conveyor speed Machining equipment (grinders, polishers) (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Installation Insert K3MA-F into panel cut-out hole. waterproof installation, insert rubber gasket onto body K3MA-F. Wiring following crimp terminals. max. max. Unit Labels (Provided) unit labels attached K3MA-F. Select desired labels from provided sheet. adaptor into grooves left right sides rear case, then push until contacts panel secure K3MA-F. Note: scales gauges, unit labels that specified relevant laws regulations. Angle View K3MA designed provide best visibility angles shown following diagram. Rubber Packing (Sold Separately) K32-P1 rubber packing lost damaged, ordered using following model number K32-P1. (Depending operating environment, deterioration, contraction, hardening rubber packing occur order ensure level waterproofing specified NEMA4, periodic replacement recommended. Note:Ruber packing provided with Controller. Wiring Precautions crimp terminals. Tighten terminal screws torque approximately avoid influence noise, route signal lines power lines separately. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Operating Procedures Operations Mode Checking Maximum Minimum Values maximum minimum values displayed pressing MAX/MIN while measurement being displayed. Measurement value MAX/MIN value MAX/MIN value MAX/MIN maximum minimum values reset pressing MAX/MIN min. when maximum minimum value displayed. Checking Setting Comparative Values (for Models with Comparative Output Function) Each time Mode pressed when measurement value, maximum value, minimum value displayed, comparative values will displayed following order: OUT1 value OUT1 upper-limit value, OUT1 lower-limit value OUT2 upper-limit value, OUT2 lower limit value Measurement value value value OUT1 value OUT2 value OUT1 upperlimit value OUT1 lowerlimit value OUT2 upperlimit value OUT2 lowerlimit value Note: When comparative value displayed, changed pressing Shift (when protection OFF). Levels "Level" refers grouping parameters. following table lists operations that possible each levels, diagram tells move between levels. There some parameters that displayed certain models. Level name Protect Operation Initial setting Advanced function setting Setting lockouts. Displaying current values, setting values. Function Continue Continue Measurement Making initial settings input type, scaling, output operating action, Stopped other parameters. Setting average processing, display color settings, other advanced function parameters. Stopped Power Level MODE least user-set time Operation level Level MODE min. Level min. Level min. Protect level Measurement progress Initial setting level Measurement stopped Level change Level min. Password input Advanced function setting level http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Parameters Note: Some parameters displayed certain models. K3MA-F will stop measurement level changed initial setting level advanced-function setting level. input range changed, some parameters default values. Therefore, input range first. Settings displayed reversed colors defaults. Power Operation level Current value models with comparative output function. MODE OUT1 value these. MODE OUT1 upper-limit value MODE OUT1 lower-limit value MODE OUT2 value MODE these. OUT2 upper-limit value MODE OUT2 lower-limit value MODE http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Press Level more than Initial setting level Press Level more than Pulse frequency MODE Scaling input value Press Level less than Advanced-function setting level Pulse frequency Enter password "-0169" MODE Scaling Parameter initialization Unit: times Comparative hysteresis Average processing MODE Models with comparative output function OUT1 hysteresis MODE Scaling display value MODE OUT2 hysteresis MODE Decimal point position MODE Auto-zero time MODE OUT1 type Upper Limit Lower Limit MODE Startup compensation time Models with comparative output function MODE OUT2 type Upper/Lower Limits MODE Upper Limit Lower Limit Upper/Lower Limits Green (red) Display color change Green (green) MODE Move advancedfunction setting level MODE Display auto-return time MODE MODE Move-toprotectlevel time Unit: MODE Unit: Settings displayed reversed colors initial settings. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Press Operation level Press Level than preset time. Mode more Level Mode more than Protect level Operation/adjustment lockouts MODE Setting level lockouts MODE Setting change lockout MODE Operation/Adjustment Lockouts Restricts operations operation level adjustment level. Parameter Setting Operation level Current value display oapt Allowed Allowed Allowed value display Allowed Allowed Prohibited Initial Settings Power Press Level level. min. move initial setting Initial setting This displayed models with comparative output function. Select pulse frequency measurement. scaling values type required. Setting Level Lockouts Restricts shifting initial setting level advanced function setting level. Parameter Setting Shift initial setting level Shift advanced function setting level Allowed Prohibited Prohibited Press Level operation level. more than second return required, shift advanced-function setting level number measurements average processing, hysteresis values, auto-zero time, startup compensation time, display color change, display auto-return time, move-toprotect-level time. icpt Allowed Allowed Prohibited Setting Change Lockout Restricts setting changes operation. When this lockout set, longer possible shift setting change mode. Parameter wtpt Setting Setting change operation Allowed Prohibited Measurement starts. Specify value However, protect level parameters still changed. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. K3MA-F Setting Example Initial Settings settings following example shown here. When displaying flowrate (e.g., l/min l/h), make scaling settings after confirming characteristics flowrate sensor. There flowrate sensors that output analog signals. this kind flowrate sensor used, consider using K3MA-J. Select maximum input frequency K3MA-F. pulse frequency selection either kHz. example, this because conveyor belt turning slow speed. Parameter: p-fre (pulse frequency), Setting value: scaling. relationship between display value input value shown following equation. Rotations (rpm) Frequency input/No. pulses rotation Cycle speed (m/min) Rotations roll circumference pulses rotation Frequency (Hz) Roller diameter When input conditions applied this equation, obtain following: Display value input display value 18.8495 (m/min). scaling settings K3MA-F must integers. Also, decrease error, scaling value multiplied 1,000, obtain input 1000 display value 18850. However, because display value this case displayed first decimal place, scaling shown following example that 18850 displayed input Parameter Setting value (scaling input value) (scaling display value) 18850 (decimal point position) %%%%.% Input value Example: Display conveyor belt feed speed E2E-X5E1 Proximity Sensor MAX/MIN LEVEL MODE SHIFT K3MA-F-A2 100-240VAC Here, conveyor belt feed speed displayed units m/min. Proximity Sensor: E2E-X5E1, output pulse/rotation, roller diameter Display value 18850 Note: decimal point position here refers position number after scaling. When setting scaling display value, necessary consider number digits displayed past decimal point. Troubleshooting When error occurs, error details will displayed main indicator. Confirm error from main indicator take appropriate countermeasures. Level display Main indicator e111 e111 Error contents memory error EEPROM memory error Countermeasures Repair necessary. Consult your OMRON sales representative. When this error displayed, press Level seconds, settings will restored factory settings. error cannot recovered, repair necessary. Consult your OMRON sales representative. Promptly change input value that falls within specified range. scaling value inappropriate. Review scaling value initial setting level. Flashes -19999 scaling display value lower than -19999. Promptly change input value that falls within specified range. scaling value inappropriate. Review scaling value initial setting level. Flashes 99999 scaling display value exceeds 99999. DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. interest product improvement, specifications subject change without notice. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 Rights Reserved. Read Understand This Catalog Please read understand this catalog before purchasing products. Please consult your OMRON representative have questions comments. Warranty Limitations Liability WARRANTY OMRON's exclusive warranty that products free from defects materials workmanship period year other period specified) from date sale OMRON. OMRON MAKES WARRANTY REPRESENTATION, EXPRESS IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, FITNESS PARTICULAR PURPOSE PRODUCTS. BUYER USER ACKNOWLEDGES THAT BUYER USER ALONE DETERMINED THAT PRODUCTS WILL SUITABLY MEET REQUIREMENTS THEIR INTENDED USE. OMRON DISCLAIMS OTHER WARRANTIES, EXPRESS IMPLIED. LIMITATIONS LIABILITY OMRON SHALL RESPONSIBLE SPECIAL, INDIRECT, CONSEQUENTIAL DAMAGES, LOSS PROFITS, COMMERCIAL LOSS CONNECTED WITH PRODUCTS, WHETHER SUCH CLAIM BASED CONTRACT, WARRANTY, NEGLIGENCE, STRICT LIABILITY. event shall responsibility OMRON exceed individual price product which liability asserted. EVENT SHALL OMRON RESPONSIBLE WARRANTY, REPAIR, OTHER CLAIMS REGARDING PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, MAINTAINED SUBJECT CONTAMINATION, ABUSE, MISUSE, INAPPROPRIATE MODIFICATION REPAIR. Application Considerations SUITABILITY OMRON shall responsible conformity with standards, codes, regulations that apply combination products customer's application product. customer's request, OMRON will provide applicable third party certification documents identifying ratings limitations that apply products. This information itself sufficient complete determination suitability products combination with product, machine, system, other application use. following some examples applications which particular attention must given. This intended exhaustive list possible uses products, intended imply that uses listed suitable products: Outdoor use, uses involving potential chemical contamination electrical interference, conditions uses described this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, installations subject separate industry government regulations. Systems, machines, equipment that could present risk life property. Please know observe prohibitions applicable products. NEVER PRODUCTS APPLICATION INVOLVING SERIOUS RISK LIFE PROPERTY WITHOUT ENSURING THAT SYSTEM WHOLE BEEN DESIGNED ADDRESS RISKS, THAT OMRON PRODUCT PROPERLY RATED INSTALLED INTENDED WITHIN OVERALL EQUIPMENT SYSTEM. Disclaimers CHANGE SPECIFICATIONS Product specifications accessories changed time based improvements other reasons. practice change model numbers when published ratings features changed, when significant construction changes made. However, some specifications product changed without notice. When doubt, special model numbers assigned establish specifications your application your request. Please consult with your OMRON representative time confirm actual specifications purchased product. DIMENSIONS WEIGHTS Dimensions weights nominal used manufacturing purposes, even when tolerances shown. ERRORS OMISSIONS information this catalog been carefully checked believed accurate; however, responsibility assumed clerical, typographical, proofreading errors, omissions. PERFORMANCE DATA Performance data given this catalog provided guide user determining suitability does constitute warranty. represent result OMRON's test conditions, users must correlate actual application requirements. Actual performance subject OMRON Warranty Limitations Liability. PROGRAMMABLE PRODUCTS OMRON shall responsible user's programming programmable product, consequence thereof. COPYRIGHT COPY PERMISSION This catalog shall copied sales promotions without permission. This catalog protected copyright intended solely conjunction with product. Please notify before copying reproducing this catalog manner, other purpose. copying transmitting this catalog another, please copy transmit entirety. 2007. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ interest product improvement, specifications subject change without notice. (c)Copyright OMRON Corporation 2007 Rights Reserved. Other recent searchesTG2206F - TG2206F TG2206F Datasheet OC-192 - OC-192 OC-192 Datasheet STM-64 - STM-64 STM-64 Datasheet MPA1000 - MPA1000 MPA1000 Datasheet K78XX-2000 - K78XX-2000 K78XX-2000 Datasheet FPP-02 - FPP-02 FPP-02 Datasheet
Privacy Policy | Disclaimer |