| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Series: BPAK Power Volt Module Features: working voltag
Top Searches for this datasheetBPAK Power Series BOOSTCAP® Ultracapacitors Series: BPAK Power Volt Module Features: working voltage individually balanced cells Rugged, fully enclosed system screw terminals Module-to-module balance cable included Recognized Applications: automotive subsystems consumer electronics short term telecom Renewable energy systems Portable power tools Overview: Power-type ultracapacitor product line gives industrial customers much wider range choices meet their energy storage power delivery requirements. modules specifically engineered provide cost-effective solutions UPS, telecommunications other lighter duty industrial electronics applications. addition meeting exceeding demanding industrial application requirements both watt-hours energy storage watts power delivery kilogram, these products will perform reliably more than five hundred-thousand discharge-recharge cycles. proprietary architecture material science which BOOSTCAP® products based enable continued leadership controlling costs, flexibility product offerings allow application specific performance tailoring. BPAK Power Series BOOSTCAP® Ultracapacitors Page Doc. 1009645 Rev. BPAK Power Series BOOSTCAP® Ultracapacitors BPAK Power Series Specifications: Item Operating Temperature Range Storage Temperature Range Rated Voltage Capacitance Tolerance Resistance Tolerance Temperature Characteristics Capacitance Change Internal Resistance Capacitance Change Internal Resistance Shelf Life Product Specification Within initial measured value Within 150% initial measured value Within initial specified value Within initial specified value After 1000 hours application rated voltage Endurance After 1000 hours storage without load shall meet specification endurance After years rated voltage Capacitance Change Internal Resistance Within initial specified value Within 100% initial specified value Life Test Cycle Test Capacitors cycled between specified voltage half rated voltage under constant current (500,000 Cycles) Capacitance Change Internal Resistance Within initial specified value Within 100% initial specified value BPAK Power Product Specifications: Part Number BPAK0020 P015 BPAK0052 P015 BPAK0052 P015 Capacitance ESR, (mohm) 14.5 14.5 (mA) 0.10 1.00 50.0 BPAK Power Product Properties: Maxwell Part BPAK0020 P015 BPAK0052 P015 BPAK0052 P015 (C/W) 2.50 1.80 1.80 1500 1500 Emax (Wh/kg) 2.72 3.25 3.25 Pmax (W/kg) 13,587 14,000 14,000 (W/kg) 3,000 3,000 3,000 BPAK Power Series BOOSTCAP® Ultracapacitors Page Doc. 1009645 Rev. BPAK Power Series BOOSTCAP® Ultracapacitors Dimensions: .314 0.566 0.566 Mass Size (mm) Part Number BPAK0020 P015 BPAK0052 P015 BPAK0052 P015 Product dimensions specifications change without notice. Please contact Maxwell Technologies directly technical specifications critical application. Units mounted operated orientation. pack should shock mounted within protective enclosure. care should taken prevent motion between pack enclosure. This motion wear through shrink-wrap covering over time expose electrically conductive surfaces. reverse polarize module. Mounting Recommendations: Markings Rated capacitance, rated voltage, part number, manufacturer, positive negative terminal, warning marking, symbol, number Patent: 6,806,686 additional Patents Pending Worldwide Headquarters Maxwell Technologies 9244 Balboa avenue Diego, 92123 Phone: +(1) 3300 Fax: +(1) 3301 eMail: info@maxwell.com European Office Maxwell Technologies ch-1728 Rossens switzerland Phone: Fax: eMail: info@maxwell.com www.maxwell.com Page Doc. 1009645 Rev. BPAK Power Series BOOSTCAP® Ultracapacitors BPAK Power Series BOOSTCAP® Ultracapacitors Additional Technical Information: capacitance esR, measured document 1007239 leakage current after hours, 25°c Thermal resistance emax 3600 mass short circuit current (maximum peak current) Pmax (1khz) mass 0.12V (DC) mass Disclaimer Warranty/Limitation Liability Uses Life Support Devices Critical Systems Maxwell Technologies, Inc. Affiliates ("Maxwell") provide warranties kind either express implied, including (without limitation) implied warranties merchantability fitness, uses products components life support devices critical systems. "Life support devices" devices systems, which intended surgical implant into living body, support sustain life, whose failure perform when properly used accordance with instructions provided labeling reasonably expected result bodily injury user. example life support device includes, limited heart pacemaker. "critical system" system whose failure perform affect safety effectiveness higher level system, cause bodily property injury loss control higher level device system. example critical system includes, limited aircraft avionics. agree that Maxwell will liable loss damages, either actual consequential, indirect, punitive, special, incidental, arising relating these terms. These terms non-waivable condition contract that Maxwell enter into. exception these terms only authorized writing signed President Maxwell duly authorized officer. Patent: 6,806,686 additional Patents Pending Worldwide Headquarters Maxwell Technologies 9244 Balboa avenue Diego, 92123 Phone: +(1) 3300 Fax: +(1) 3301 eMail: info@maxwell.com European Office Maxwell Technologies ch-1728 Rossens switzerland Phone: Fax: eMail: info@maxwell.com www.maxwell.com Page Doc. 1009645 Rev. BPAK Power Series BOOSTCAP® Ultracapacitors Other recent searchesTDF8771A - TDF8771A TDF8771A Datasheet SY58038U - SY58038U SY58038U Datasheet SHD116117 - SHD116117 SHD116117 Datasheet SHD116117B - SHD116117B SHD116117B Datasheet PIC18F2455 - PIC18F2455 PIC18F2455 Datasheet 2550 - 2550 2550 Datasheet 4455 - 4455 4455 Datasheet 4550 - 4550 4550 Datasheet OPA1013 - OPA1013 OPA1013 Datasheet NC7S08 - NC7S08 NC7S08 Datasheet MC34066 - MC34066 MC34066 Datasheet MC33066 - MC33066 MC33066 Datasheet MC34066 - MC34066 MC34066 Datasheet MC33066 - MC33066 MC33066 Datasheet DP83848H - DP83848H DP83848H Datasheet
Privacy Policy | Disclaimer |