ELECTRONIC COUNTER (with pre-scaling function) LC4H-S Counters


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



LC4H-S
ELECTRONIC COUNTER (with pre-scaling function)
LC4H-S Counters
File No.: E122222 C-UL File No.: E122222
Features
Bright Easy-to-Read Display brand bright 2-color backlight display. easy-to-read screen location makes checking setting procedures cinch. Easy use, simple operation, simple settings Operation modes (input/output modes) easily, using switches side panel. Values easily, using switches front panel. Pre-scaling function provided pre-scaling function enables conversion lengths volumes desired values, displays results. Built-in power supply highcapacitance sensor internal power supply drives VDC, high-capacitance sensor. power supply types only) Photoelectric switches, proximity switches encoders directly connected. Dual-path sensor connected. Basic insulation between power supply input terminal (only sensor type model with power supply) There need caution when connecting between terminals. Conforms IP66's Weather Resistant Standards water-proof panel keeps water dirt reliable operation even poor environments. 4-digit 6-digit display sizes displays offered choose that suits your needs. Screw terminal Type Both Standard Options terminal types standard options support either front panel installation embedded installation. Compliant with c-UL Price this affordable price provide with unmatched cost performance.
4-digit type
6-digit type
type
Screw terminal type
RoHS Directive compatibility information http://www.nais-e.com/
Product types
Digit Count speed Operation mode Output Operation voltage Relay Maintain output/hold count Maintain output/over count Maintain output/over count shot/over count shot/recount shot/recount shot/hold count modes) Transistor Relay Transistor None None Power sensor 100mA Terminal pins Screw terminal pins Screw terminal pins Screw terminal pins Screw terminal pins Screw terminal pins Screw terminal Part LC4H-PS-R4-AC240V LC4H-PS-R4-AC240VS LC4H-S-R4-24V LC4H-S-R4-24VS LC4H-S-T4-24V LC4H-S-T4-24VS LC4H-PS-R6-AC240V LC4H-PS-R6-AC240VS LC4H-S-R6-24V LC4H-S-R6-24VS LC4H-S-T6-24V LC4H-S-T6-24VS
None
Hz/5 switchable
100mA
None
Notes) Rubber packing (ATC18002) mounting frame (AT8-DA4) included. outputs (11-pin terminal, screw-tightening terminal) types also supported.
Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
LC4H-S
Part names
4-digit display type
COUNTER
Controlled output indicator value display Reset indicator Lock indicator
RESET LOCK
switches
Counter display
Reset switch Set/lock switch
keys
SET/ LOCK
LC4H
Down keys
DOWN
(Same screw terminal type)
6-digit display type
COUNTER
Controlled output indicator value display Reset indicator Lock indicator
RESET LOCK
switches
Counter display
Reset switch Set/lock switch
keys
SET/ LOCK
LC4H
(Same screw terminal type)
Specifications
Item Rated operating voltage Rated frequency Rated power consumption Rated control capacity Input mode Max. counting speed Counting input (input input Reset input Lock input Rating Input signal Output mode shot output time Indication Digit Decimal point Pre-scaling Memory Power senser Contact arrangement Initial contact resistance Contact material Mechanical (contact) Electrical (contact) Operating voltage range Initial withstand voltage Electrical Initial insulation resistance Temperature rise Functional Vibration resistance Destructive Functional Shock resistance Destructive Ambient temperature Ambient humidity pressure Ralay output type type DC/AC type DC/24 50/60 common Transistor output type DC/AC type DC/24
Contact
Life
Mechanical
Operating conditions
Connection Protective construction
Max. Max. (resistive load) Addition (UP)/Subtraction (DOWN)/Direction (DIR)/Individuality (IND)/Phase (PHASE) modes selectable switches (selectable switches) 16.7 Hz/0.1 time: time Min. input signal width: (selected switches) Min. input signal width: Contact, Open collector input/DC two-wire system sensor Input impedance: less, Input residual voltage: less, Open impedance: less, Max. energized voltage: HOLD-A, HOLD-B, HOLD-C, SHOT-A, SHOT-B, SHOT-C, SHOT-D, modes selectable switches 0.5s, 0.2s, 0.1s, 0.05, 0.01s 7-segment LCD, Counter value (backlight LED), Setting value (backlight yellow LED) 4-digit display type -999 9999 9999 setting) 6-digit display type -99999 999999 999999 setting) three digits 0.001 9.999 (4-digit type), 0.001 99.999 (6-digit type) EEP-ROM (Overwriting times: ope. more) (±10%) Max. Form (Open collector) Form alloy/Au flush ope. (Except switch operation parts) ope. rated control voltage) ope. rated control voltage) 10.8 26.4 20.4 26.4 Between live dead metal parts: 2,000 Vrms (pin type) Between input output: 2,000 Vrms Between live dead metal parts: Min. (pin type) Between input output: Min. Max. (under flow nominal operating current nominal voltage) cycle/min), single amplitude: 0.35 axes) cycle/min), single amplitude: 0.75 axes) Min. m/s2 times axes) Min. m/s2 times axes) -10° +14° +131° Max. (non-condensing) 1,060 11-pin/screw terminal IP66 (front panel with rubber gasket)
Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
LC4H-S
Applicable standard
Safety standard EN61812-1 (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity electromagnetic field immunity EFT/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/Instantaneous stop/Voltage fluctuation immunity Pollution Degree 2/Overvoltage Category EN55011 Group1 ClassA EN55011 Group1 ClassA EN61000-4-2 contact EN61000-4-3 modulation GHz) pulse modulation (895 MHz) EN61000-4-4 (power supply line) (signal line) EN61000-4-5 (power line) EN61000-4-6 modulation (0.15 MHz) EN61000-4-8 EN61000-4-11 (rated voltage) (rated voltage) 1,000 (rated voltage) 5,000 (rated voltage)
Dimensions
type (Flush mount/Surface mount)
(1.890
COUNTER
inch General tolerance: ±1.0 ±.039
Screw terminal type: M3.5 (Flush mount)
.217 64.5 2.539
.217
55.6 2.189
70.1 2.760
14.5 .571
(1.890
RESET
((44.5) ((1.752)
((44.5) ((1.752)
SET/LOCK
LC4H
DOWN
.295
2.874* 87.5* 2.445*
81.9* 3.224* With power supply sensor With power supply sensor
6-digit display type same dimensions.) Dimensions flush mounting (with adapter installed) Screw terminal type
Rubber gasket ATC18002 (supplied) Panel Mounting frame flush mount AT8-DA4 (supplied)
type
Rubber gasket ATC18002 (supplied) Panel Mounting frame flush mount AT8-DA4 (supplied) type pins cap: ATA4861 (sold separately)
COUNTER
COUNTER
(44.5 (1.752
1.890
1.969
2.598
1.969
1.890
LOCK RESET
LOCK RESET
SET/LOCK
SET/LOCK
DOWN
LC4H
LC4H
1.890
.039
2.598
63.5 2.500
80.9 3.185 With power supply sensor
1.890
3.543
104.5 4.114
With power supply sensor
Dimensions front panel installations
Installation panel cut-out dimensions
standard panel cut-out dimensions shown below. mounting frame (AT8-DA4) rubber gasket (ATC18002).
connected installations
rail terminal block 11-pin type: AT8-DF11K (sold separately) 45-0.6 1.772-.024
45-0.6 1.772-.024
Min. 3.150
45-0.6 1.772-.024
Min. 3.150
Device installation rail ATA48011 (sold separately)
When units attached continuous series, dimension -0.6 2.5)
95.5 (112.9) 3.760 (4.445) With power supply sensor
Note installation panel thickness should between .039 .197 inch. Note connected installations, waterproofing ability between unit installation panel lost.
Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
LC4H-S
Terminal layouts Wiring diagrams
type
Relay output type
Reset Input Input Lock
Transistor output type
Reset Input Input Lock
With power supply sensor Relay output type Transistor output type
Reset Input Input Lock
100mA Max.
Reset Input Input Lock
100mA Max.
Operating voltage
Operating voltage
~Operating~
voltage
~Operating~
voltage
Screw terminal type
Relay output type
Reset Input Input Lock
Transistor output type
Reset Input Input Lock
With power supply sensor Relay output type Transistor output type
Reset Input Input Lock
100mA Max. 100mA Max.
Reset Input Input Lock
Operating voltage
Operating voltage
~Operating~
voltage
~Operating
voltage
Note) connecting output leads transistor output type, refer Transistor output page 141.
Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
LC4H-S
Setting operation mode counter
Setting procedure Setting operation mode (input mode output mode) input output modes with switches side counter. switches
Item switch Refer table
Table Setting output mode
switch Output mode SHOT-A SHOT-B SHOT-C SHOT-D HOLD-A HOLD-B HOLD-C (See note
Output mode Minimum reset input signal width Maximum counter setting Input mode
Refer table
Table Setting input mode
switches (See note
(Same 6-digit, screw-down terminal type)
switch Input mode Addition input Subtraction input Directive input Independent input Phase input (See note (See note (See note Notes:1) counter value displays will display Err. Notes:2) switches before installing counter panel. Notes:3) When setting changed, turn power once. Notes:4) switches before shipping.
Setting procedure Setting value value with DOWN keys front counter. Front display section 4-digit display type Counter display value display Controlled output indicator Reset indicator Lock indicator keys Changes corresponding digit value addition direction (upwards)
COUNTER
RESET LOCK
SET/LOCK
LC4H
DOWN
DOWN keys Changes corresponding digit value subtraction direction (downwards) RESET switch Resets counting value output SET/LOCK switch This used handle pre-scaling values, one-shot times, decimal point position settings, lock operations disable key, Down key, Reset operations). keys Changes corresponding digit value addition direction (upwards) RESET switch Resets counting value output SET/LOCK switch This used handle pre-scaling values, one-shot times, decimal point position settings, lock operations disable key, Down key, Reset operations).
6-digit display type Counter display value display Controlled output indicator Reset indicator Lock indicator
COUNTER
RESET LOCK
SET/LOCK
LC4H
Setting procedure Setting input mode input mode using switch [Display] section front counter. Decimal point position setting mode Holding down [SET/LOCK] key, press second digit access decimal point position setting mode. Example) 6-digit type Decimal point position setting mode display (Example shows default value displayed) When setting mode been accessed, release [SET/LOCK] key.
Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
LC4H-S
decimal point using [UP] [DOWN] keys specify 2nd, 3rd, digits (this applies only 4-digit models).(The digit using [UP] [DOWN] settings where there decimal point (this applies only 4-digit models).) Example) 6-digit type Example shows digit displayed using [UP]
Press [RESET] displayed decimal point position return normal operation. Setting pre-scaling value Holding down [SET/LOCK] key, press first digit access pre-scaling value setting mode. Example) 4-digit type Example) 6-digit type Pre-scaling value setting mode displayed (Example shows default values displayed)
When setting mode been accessed, release [SET/LOCK] key. [UP] [DOWN] pre-scaling value (this applies only 4-digit models). Select either: 0.001 9.999 (4-digit) 0.001 99.999 (6-digit) Press [RESET] displayed pre-scaling value return normal operation. Setting one-shot output time Holding down [SET/LOCK] key, press third digit access one-shot output time setting mode. Example) 6-digit type One-shot output time setting mode displayed (Example shows default value displayed) When setting mode been accessed, release [SET/LOCK] key. Each time 1st-digit [UP] pressed, one-shot output time changes following sequence, moving right: 0.05 0.01 (With 4-digit type, [DOWN] also used move left.) Press [RESET] displayed one-shot output time return normal operation.
Changing value
possible change value with down keys (4digit type only) even during counting. However, aware following points. value changed less than count value with counting addition direction, counting will continue until reaches full scale (9999 with 4-digit type 999999 with 6-digit type), returns zero, then reaches value. value changed value above count value, counting will continue until count value reaches value. Suppose that thew counter preset count down. Whether preset countdown value smaller larger than count value, counter counts down (zero)". value changed "0," unit will complete count-up. starts counting when counting value comes (zero)" again. Up-count (addition) input When counting addition direction, counting will continue until full scale reached (9999 with 4-digit type 999999 with 6-digit type), return zero, then complete countup. Down-count (subtraction) input When counting subtraction direction, counting will continue until full scale reached (-999 with 4-digit type -99999 with 6-digit type), then display will change with 4-digit type with 6-digit type. counting value does become (zero)" counter does count Directive, independent, phase inputs counting value counted down number other than once. When comes (zero)" again, counter starts counting
CAUTIONS
more information regarding cautions LC4H series counter, refer page "PRECAUTIONS USING LC4H SERIES".
Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
LC4H-S
Operation mode
Input mode input mode, choose following five modes Addition Subtraction Directive Independent Phase
Input mode DOWN PHASE
Operation works input block (gate) other input.
*Minimum input signal width 16.7 kHz: Example where counting input input block (gate).
Blocked Count-up completed
Addition
Counting (addition) Counting (subtraction)
Reset
Example where counting input input block (gate).
Reset Count-up completed Blocked Blocked
Subtraction DOWN
Counting (addition) Counting (subtraction)
must more than minimum input signal width. counting input addition subtraction directive input. adds level subtracts level. Directive
Counting
Addition Reset
Subtraction
Addition
must more than minimum input signal width. addition input subtraction input.
Reset
Independent
Counting
completely independent, there restriction signal timing. Addition when phase advances beyond IN2, subtraction when phase advances beyond IN1. Phase PHASE
Counting
Phase advance Reset Phase retard
must more than minimum input signal width. Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
LC4H-S
Output mode output mode, choose following seven modes Maintain output/hold count Maintain output/over count Maintain output/over count shot/over count shot/recount shot/recount shot/hold count
Output mode HOLD-A HOLD-B HOLD-C SHOT-A SHOT-B SHOT-C SHOT-D Operation Output control maintained after count-up completion until resetting. During that time, count display does change from that count-up completion. (Example when input mode either addition subtraction)
Counting (addition) Counting (subtraction) Counting able/unable Output control Able Unable
Maintain output Hold count HOLD-A
value Output control maintained after count-up completion until resetting. However, counting possible despite completion count-up.
Counting (addition) Counting (subtraction) Counting able/unable Output control Able
Maintain output Over count HOLD-B
value Output control maintained after count-up completion until next signal enters. However, counting possible despite completion countup.
Counting (addition) Counting (subtraction) Counting able/unable Output control Able
Maintain output Over count HOLD-C
value Output control maintained after count-up completion shot output time. Counting possible despite completion count-up.
Counting (addition) Counting (subtraction) Counting able/unable Output control Able Approx.
shot Over count SHOT-A
value Output control maintained after count-up completion shot output time. Counting possible despite completion count-up. However, reset occurs simultaneous with completion count-up. While output being maintained, restarting count possible Output control maintained after count-up completion shot output time. Counting possible despite completion count-up. However, reset occurs simultaneous with output OFF.
Counting (addition) Counting (subtraction)
shot Recount SHOT-B
Reset (automatic) Counting able/unable Output control Approx. Able
value
Counting (addition) Counting (subtraction)
shot Recount SHOT-C
Reset (automatic) Counting able/unable Output control Approx. Able
value Output control maintained after count-up completion shot output time. During that time, count display does change from that count-up completion. Reset occurs simultaneous with output OFF.
Counting (addition) Counting (subtraction)
shot Hold count SHOT-D
Reset (automatic) Counting able/unable Output control Approx. Able Unable Able
value
Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
LC4H-S
Input connections
Signal input type
Open collector
(PC, sensor etc.)
voltage output
Output (Photoelectric sensor, proximity sensor, etc.)
Output
11-pin type Screw-down terminal type
11-pin type Screw-down terminal type
Lock Input Input Reset input output input
Lock Input Input Reset input output input
Contact input
Relay, switches etc.
rotary encoder
phase phase
11-pin type Screw-down terminal type
11-pin type Screw-down terminal type
Lock Input Input Reset input input
Input Input output
Input input reset input specifications
Impedance during short-circuit: max. outflow current approximately mA.) Residual voltage during short-circuit: max. Impedance when released: min. Max. applied voltage: max.
Lock input specifications
Impedance during short-circuit: max. outflow current approximately mA.) Residual voltage during short-circuit: max. Impedance when released: min. Max. applied voltage: max. contact relay should which open/close
There with DC/24 types.
dual-line sensor
What prescale function?
prescale function converts count into actual value (amount) displays Example device that outputs pulses when been fed: decimal position last place. prescale value 0.002 (1/500).
11-pin type Screw-down terminal type
3.281ft
Input Input Reset input
COUNTER
Dual-line sensor specifications
Leakage current: max. Breaker capacitance: min. Residual voltage: max. Usable voltage: Runs dual-line sensor connected VDC/24 type, (21.6 26.4 VDC) (21.6 26.4 VAC) should applied power supply voltage counter.
Encoder pulses
COUNTER
pulse
RESET
SET/LOCK
LC4H
DOWN
easy-to-understand unit. Prescale value: 0.002
RESET
SET/LOCK
LC4H
DOWN
Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.

Other recent searches


ZFx86TM - ZFx86TM   ZFx86TM Datasheet
XF-G2457CG - XF-G2457CG   XF-G2457CG Datasheet
TO39-3A - TO39-3A   TO39-3A Datasheet
PS21765 - PS21765   PS21765 Datasheet
PDN0303 - PDN0303   PDN0303 Datasheet
LNJ211R8ARA - LNJ211R8ARA   LNJ211R8ARA Datasheet
HVF1206-HVF2512 - HVF1206-HVF2512   HVF1206-HVF2512 Datasheet
AMS4040 - AMS4040   AMS4040 Datasheet
AMS4041 - AMS4041   AMS4041 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive