| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
LC2H Counter Preset function equipped half size 0.945 1.890 inch)
Top Searches for this datasheetPRESET COUNTER LC2H Counter Preset function equipped half size 0.945 1.890 inch). Display backlight instant recognition. Counting Counting (Green) (backlight) 0.343 inch Character Height (previously 0.276 inch) Easy-to read character height increased from 0.276 inch 0.343 inch. 8.7mm .343inch Plenty Digits Green (Red) (backlight) (Lit Flashing) Green selected setup. (Green) (backlight) digits Counting Speed Switchable between Conforms IP66 Protective Construction (Front panel surface) Weatherproofing supported using optional mounting frame rubber gasket Includes reassuring lock mode lock switch prevent erroneous operation. Screw terminals constructed protect fingers ensure safety. Compliant with c-UL (Lit Flashing) Flashing selected setup. RoHS Directive compatibility information http://www.nais-e.com/ Product types digits digits Counting speed Hz/5 switchable Options Output mode Output Maintain output/hold count Maintain output/over count Transistor (1a) shot/over count shot/recount Mounting frame Rubber gasket Operating voltage Part LC2HP-FEW-B-DC24V ATH3803 ATH3804 waterproofing (front panel surface) Note: Mounting frame rubber gasket included. Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Specifications Item Rated operating voltage Rated power consumption Rated control capacity Input mode Max. counting speed Counting input Reset input Rating Input signal Descriptions Max. Addition/Subtraction (selectable front switch) Hz/5 (selectable slide switch side) Min. input signal width: 16.7 Hz/0.1 kHz, time time Min. input signal width: Min. Non-voltage input using contacts open-collector connection Input impedance; when shorted: Max. when open: Min. Residual voltage: Max. Maintain output/hold count Maintain output/over count shot/over count shot/recount (Selectable front switch) 7-segment (Switch between green backlight, between flashing count up.) -9999999 99999999 digits digits) 99999999 preset value) EEP-ROM (Overwriting times: operations more) Form (Open collector) operations rated control voltage) 110% rated operating voltage Between input output: 1,500 min. Between input output: cycle/min), Single amplitude: 0.15 min. axes) cycle/min), Single amplitude: 0.375 axes) Min. m/s2 times axes) Min. m/s2 times axes) 55°C +131°F (without frost dew) +65°C +149°F (without frost dew) 25°C 77°F, non-condensing) IP66 (front panel with mounting bracket rubber gasket) Output mode Display method Digit Memory Contact arrangement Electrical life (contact) Allowable operating voltage range Break down voltage (Initial value) Insulation resistance (Initial value) Functional vibration resistance Destructive vibration resistance Mechanical Functional shock resistance Destructive shock resistance Operation temperature Operating Storage temperature conditions Ambient humidity Protective construction factory default preset value 1000000. Electrical Applicable standard (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity electromagnetic field immunity EFT/B immunity Conductivity noise immunity Power frequency magnetic field immunity EN55011 Group1 ClassA EN55011 Group1 ClassA EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-6 EN61000-4-8 contact modulation GHz) pulse modulation (895 MHz) (power supply line) (signal line) modulation (0.15 MHz) Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Part names Front reset This resets count value. does work when lock switch Mode switch between each mode. Setting Used digits preset values each mode. preset values switch between modes. Lock switch Disable operation front panel reset mode key. With lock switch displayed about seconds when reset mode switch operated. Count speed switch this switch switch count speed between kHz. COUNTER RESET MODE Default setting when shipped. (Terminal block side) Lock switch (unit display (LCD side) (Terminal block side) 5kHz Count speed switch (unit display (LCD side) 30Hz Notes: Make switch setting before installing panel. Please turn power change setting count speed switch when power setting will become valid when power turned back Dimensions External dimensions 44.8 1.764 inch General tolerance: ±1.0 ±.039 54.4 2.142 10.4 .409 .866 1.732 .197 1.890 COUNTER RESET MODE .945 When installing one-touch installation type model, make sure that installation spring does pinch rubber gasket. prevent installation spring from pinching rubber gasket: rubber gasket both ends installation spring (left right). Confirm that installation spring pinching rubber gasket, then insert installation spring place from rear timer unit. .276 Panel dimensions standard panel shown below. mounting bracket (ATH3803) rubber gasket (ATH3804). (Only installation frame type) When installing repeatedly (sealed installation) (Only installation frame type) 22.2+0.5 .874+.020 min. 2.362 min. 45+0.5 1.772+.020 +0.5 +.020 Notes: Suitable installation panel thickness 0.39 0.177 inch. Waterproofing will lost when installing repeatedly (sealed installation). 22.2 .874 Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Preset value setting mode This mode setting preset values. display reads "Un-Lock" after entering lock mode (initial setting). Display after entering lock mode (Example showing "Un-Lock".) Press MODE key. digit. value. Pressing MODE takes preset value setting mode. Sample display preset value setting mode (when preset value 1000) Pressing setting changes display between Lock" "Unlock". (Example showing Lock".) backlight changes from flashing green flashing green with each press setting key. Pressing front panel reset sets current backlight color returns regular operation mode. Note: will returned regular operation mode press front panel reset key. Pressing setting moves flashing digit left one. Following highest digit returns lowest digit each time digit setting pressed moves left. Pressing increases value one. (After returns then changes etc.) Pressing front panel reset sets displayed preset value returns regular operation mode. preset value setting mode operate digit setting seconds more will returned regular operation. this case preset value will change. Lock mode This mode prohibits everything except preset value setting mode. Press while pressing MODE key. Un-Lock Lock Pressing front panel reset sets content displayed returns regular operation mode. Note: will returned regular operation mode press front panel reset key. Input setting mode This mode setting addition subtraction. Press while pressing MODE key. Addition Subtraction When lock mode display reads Lock", will able move backlight setting mode, input setting mode, output setting mode. Backlight setting mode This mode setting backlight during count Press while pressing MODE key. green Flashes green Flashes Pressing three times while holding down MODE takes input setting mode. display after entering input setting mode reads (initial setting). Display after entering input setting mode (Example showing "UP") Pressing times while holding down MODE takes backlight setting mode. display backlight setting mode reads LEd" Display after entering backlight setting mode. Pressing setting changes display "dn" (subtraction) pressing again changes "UP" (addition). display alternates between "dn" "UP". (Example showing "dn") Pressing while holding down mode takes lock mode. Pressing front panel reset sets content displayed returns regular operation mode. Note: will returned regular operation mode press front panel reset key. backlight will (initial setting). Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Output setting mode This sets operation mode. Press while pressing MODE key. HOLD-A SHOT-B HOLD-B SHOT-A Lock mode Press while pressing MODE key. Un-Lock Lock When lock set, cannot enter modes other than backlight setting mode. Backlight setting mode Pressing four times while holding down MODE takes output setting mode. display reads "HoLd-A" (initial setting) after entering output setting mode. Press while pressing MODE key. green Flashes green Flashes Front panel reset Input setting mode Pressing setting causes display change follows: HOLD-B (Output maintain/over count Press while pressing MODE key. Addition Subtraction Regular operation mode Output setting mode Press while pressing MODE key. HOLD-A SHOT-B HOLD-B SHOT-A SHOT-A (One shot/over count) Mode changes follows pressing while holding down MODE key. Lock mode Output setting mode Backlight setting mode Input setting mode SHOT-B (One shot/recount HOLD-A (Output maintain/hold count) Pressing front panel reset sets display content returns regular operation mode. Note: will returned regular operation mode press front panel reset key. Please aware that after doing front panel reset returning regular operation mode, preset values, count value output will shown this table. Preset value Lock mode Backlight setting mode Input setting mode Output setting mode Count value Addition: Subtraction: "Preset value" Addition: Subtraction: "Preset value" Output change ONOFF ONOFF Note: sign: change Changing preset value possible change preset value even during counting. However, aware following points. preset value changed less than count value with counting addition direction, counting will continue until reaches full scale, returns zero, then reaches preset value. preset value changed value above count value, counting will continue until count value reaches preset value. Suppose that counter preset count down. Whether preset count down value smaller larger than count value, counter counts down (zero)". preset value changed "0", counter will complete countup. starts counting when counting value comes (zero)" again. Addition (up-count) input when counting addition direction, counting will continue until full scale reached, return zero, then complete count-up. Subtraction (down-count) input when counting subtraction direction, counting will continue until full scale "-9999999" reached, then display will change Compliance with marking Directive (89/336/EEC) LC2H Preset Counter conforms Directive simple counter. Applicable standards: EN61000-6-4, EN61000-6-2 Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Operation mode Output mode Operation Output control maintained after count-up completion until resetting. During that time, count display does change from that count-up completion. Example when input mode either addition Subject:ubtraction Output Counting able/unable Addition Subtraction Able Unable Output maintain/ hold count HOLD-A Preset value Output maintain/ over count HOLD-B Output control maintained after count-up completion until resetting. However, counting possible despite completion count-up. Output Counting able/unable Addition Subtraction Able Preset value shot/ over count SHOT-A Output control maintained after count-up completion fixed time (approx. sec.). Counting possible despite completion count-up. shot pulse width: approx. sec. Output Counting able/unable Addition Subtraction Able Preset value shot/ recount SHOT-B Output control maintained after count-up completion fixed time (approx. sec.). Counting possible despite completion count-up. However, reset occurs simultaneous with completion count-up. While output being maintained, restarting count possible. shot pulse width: approx. sec. Output Counting able/unable Addition Subtraction Able Preset value Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Cautions Input output connection Input connection Contact input highly reliable metal plated contacts. Since contact's bounce time leads directly error count value, contacts with short bounce time possible. general, select input have maximum counting speed Count input Reset input VCEO Min. Min. ICBO Max. Also, transistors with residual voltage less than when transistor short-circuit impedance should less than Non-contact input (Transistor input) Connect with open collector. transistors whose characteristics satisfy criteria given below. (When impedance current coming from count input terminal approximately from reset input terminal approximately mA.) Also, open-circuit impedance should more than Count input Reset input Input wiring When wiring, shielded wires metallic wire tubes, keep wire lengths short possible. Output connection Since transistor output counter insulated from internal circuitry photo-coupler, used output (equal value) output. output Load Load's power supply output Load Load's power supply Self-diagnosis function malfunction occurs, following displays will appear. Display Output Restoration Preset values after condition procedure restoration preset value Malfunctioning Enter front start-up before reset malfunction occurred. restart counter Malfunctioning memory* Contents Err-00 Err-01 Terminal connection When wiring terminals, refer terminal layout wiring diagrams sure perform wiring properly without errors. external power supply required order main unit. Power should applied between terminals (2). Terminal acts positive connection terminal negative. Operating voltage Includes possibility that EEP-ROM's life expired. After turning counter off, make sure that resulting induced voltage residual voltage applied power supply terminals through (2). power supply wire wired parallel high voltage wire power wire, induced voltage generated power supply terminal.) Have power supply voltage pass through switch relay that applied time. Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Other recent searchesTA75639 - TA75639 TA75639 Datasheet PIC16F87X - PIC16F87X PIC16F87X Datasheet PIC16F873 - PIC16F873 PIC16F873 Datasheet PIC16F874 - PIC16F874 PIC16F874 Datasheet PIC16F876 - PIC16F876 PIC16F876 Datasheet PIC16F877 - PIC16F877 PIC16F877 Datasheet NCP3011 - NCP3011 NCP3011 Datasheet KT-2520QB10ZS-RV - KT-2520QB10ZS-RV KT-2520QB10ZS-RV Datasheet HYMD18645A - HYMD18645A HYMD18645A Datasheet ELD-572-524 - ELD-572-524 ELD-572-524 Datasheet CD4041UB - CD4041UB CD4041UB Datasheet AS1322 - AS1322 AS1322 Datasheet
Privacy Policy | Disclaimer |