| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Rheinland Illuminated pushbutton, non-illuminated pushbutton, sel
Top Searches for this datasheetSeries: dia. types (ACEL, ACBL, ACSL, ACKL) Rheinland Illuminated pushbutton, non-illuminated pushbutton, selector, selector switches Series (mounting hole dia. type) Tight, space-saving mounting Bright, clear illumination (ultra-high intensity used) Separate mounting model features removable lock lever Emergency pushbutton switches equipped with safety lock mechanism. Contacts have forced contact separation mechanism. button diameters available, Safety lock mechanism safety lock mechanism used which contact does move until pushbutton completely locked. Because contact does operate unless button been pressed down, there danger machine suddenly stopping because malfunction caused something coming contact with button, loss from such situations. FEATURES Bright, clear illumination Uses brilliantly illuminating LEDs that much brighter than incandescent bulbs. Brightness greatly increased vastly improved recognition safety. Yellow green particularly easy distinguish. Makers especially concerned about product liability laws worker safety sanitation calling machines that designed manufactured based ISO12100 series international safety standards (general regulations governing basic conceptual design machine safety). With ISO12100 series, manmachine interface must designed that status machine recognized clearly correctly anyone running machine, without special training expertise. that reason, display lamp colors standardized under IEC60073, IEC60204-1 other standards cited ISO12100 series, covered standards well. illumination type meets safety needs such these, beyond. Note) IEC60073: 0448 Colors Display Units Operation Devices IEC60204-1: 9960-1 Safety Machines Electrical Units Machines Display lamp colors meanings indicating machine status (taken from International Electrical Standards Conference IEC-60073 60204-1) Color Meaning Emergency Explanation Hazardous situation Problem status/urgent critical situation Normal status Displays status action required operator other status; used when using red, yellow, green, blue might interpreted erroneously. Operator action Action appropriate hazardous situation Visual monitoring (or) intervention appropriate Obligatory action Yellow Caution Green Normal Blue Obligatory Forced contact separation mechanism mechanism designed that button operation force used, contact separation force. Therefore, circuit will shut perfectly even problem happens occur such contact welding shut. (Conforms EN60947-5-1 Annex button diameters available, Nice, light switching feel. Light operation load snap action mechanism. Short stroke type. Relationship between operation load stroke (Mounting hole dia. type: Form contact momentary action) Operation load Stroke (mm) White Neutral Visual monitoring Power consumption greatly reduced type). power consumption been reduced type (mounting hole dia. type). Continuous illumination with need replacement years (50,000 hours). Products available illuminated colors: red, orange, yellow, green, blue, white. Rated current Mounting hole Mounting hole dia. type dia. type previous model) previous model) type Stroke: Mechanical life (mounting hole dia. type) Momentary type: Min. times better than previous) Alternate type: Min. (2.5 times better than previous) Series: dia. types (ACEL, ACBL, ACSL, ACKL) Removal/installation type with lock lever system. Smooth installation possible. tight mounting type added. Space saving realized with small installation area. easy install tight spaces maintenance easy. Operation efficiency greatly increased since surface installation wiring operations carried separately. Mounting hole dia. type Lock lever Mounting hole dia. type exterior configuration diagram Stroke: 36mm (when set) Mushroom button type easier operation. Splashproof type protective construction (IP65). Conforms 60529. Safety standard certified (excluding buzzer). Conforms standard (excluding buzzer), received marking. Durability Thermoplastic materials used durability outer casing installation points. Contacts made cadmium-free material. RoHS Directive compatibility information http://www.nais-e.com/ ORDERING INFORMATION Illuminated pushbutton switches (LED illumination) indicators (display lamps) ACEL Illumination type type Mounting holes flange shapes (With transparent button type) Mounting hole Flange shape dia. dia. projecting type dia. square flat type dia. flat type (With mushroom button type) Mounting hole Flange shape dia. dia. dia. dia. Protective construction Splashproof type (IP65) poles operating characteristics Indicator (indicator lamp) Single-pole Form momentary Double-pole Form momentary Contact material Indicator (indicator lamp) contact) Standard type (Silver contact) voltages pushbutton colors Pushbutton color AC/DC AC/DC Orange Yellow Color Green Blue Single-pole Form alternate Double-pole Form alternate Low-level circuit type (Gold-clad contact) voltage White (LED: opaque) Terminal shape mounting dimensions Nil: solderable terminal, tight mounting Terminal board tight mounting (only gold contact) Color types Nil: Regular Mushroom button type There mushroom button type indicator (indicator lamp). Series: dia. types (ACEL, ACBL, ACSL, ACKL) Pushbutton switches (non-illuminated types transparent buttons) ACBL Mounting holes flange shapes (With transparent button type) Mounting hole Flange shape dia. dia. projecting type dia. square flat type dia. flat type (With mushroom button type) Mounting hole Flange shape dia. dia. dia. dia. Protective construction Splashproof type (IP65) poles operating characteristics Single-pole Form momentary Double-pole Form momentary Contact material Standard type (Silver alloy contact) Types color caps Transparent button Pushbutton colors Transparent button (Mushroom button: clear) Orange Yellow Green Blue White Black Mushroom button Single-pole Form Alternate Double-pole Form Alternate Low-level circuit type (Gold-clad contact) Note: Mushroom button type available orange. Terminal shape mounting dimensions Nil: solderable terminal, tight mounting Terminal board tight mounting (only gold contact) Selector switches ACSL Mounting holes flange shapes <Mounting hole Flange shape> dia. square flat type dia. flat type dia. dia. flat type Protective construction Splashproof type (IP65) Operation methods 2-notch manual reset 3-notch manual reset (Double poles only) poles Single pole (2-notch only) Contact material Standard type (Silver contact) Note: Terminals board also possible. Note) Manual reset: Switch rotated turn remains when released. Automatic reset: Switch rotated turn goes when released. Double poles Low-level circuit type (Gold-clad contact) Series: dia. types (ACEL, ACBL, ACSL, ACKL) selector switches ACKL Mounting holes flange shapes <Mounting hole Flange shape> dia. square flat type dia. flat type dia. dia. flat type Protective construction Splashproof type (IP65) Operation methods removal positions 2-notch manual reset: position 2-notch manual reset: position 2-notch manual reset: Both positions 2-notch automatic reset: position (mounting hole dia. type only) 3-notch manual reset single pole; double poles only) (Key removed positions) poles Single pole Double poles Low-level circuit type (Gold-clad contact) Contact material Standard type (Silver contact) type Standard Note: Terminals board also possible. Series: dia. types (ACEL, ACBL, ACSL, ACKL) TYPES Illuminated pushbutton switches (LED illumination) dia. projecting type square flat type flat type dia. mushroom button type dia. mushroom button type Form poles Contact material Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) dia. projecting type Single pole Double poles Single pole square flat type Double poles Single pole Double poles dia. mushroom button type Single pole Double poles Single pole Double poles flat type dia. mushroom button type Splashproof type (IP65) Momentary Alternate Part Part ACEL2211 ACEL2231 ACEL2212 ACEL2232 ACEL2221 ACEL2241 ACEL2222 ACEL2242 ACEL3211 ACEL3231 ACEL3212 ACEL3232 ACEL3221 ACEL3241 ACEL3222 ACEL3242 ACEL4211 ACEL4231 ACEL4212 ACEL4232 ACEL4221 ACEL4241 ACEL4222 ACEL4242 ACEL0211 ACEL0231 ACEL0212 ACEL0232 ACEL0221 ACEL0241 ACEL0222 ACEL0242 ACEL0211 ACEL0231 ACEL0212 ACEL0232 ACEL0221 ACEL0241 ACEL0222 ACEL0242 White Opaque Notes) following combinations numbers letters entered square symbol indicate voltage pushbutton color. Pushbutton color AC/DC AC/DC Orange Yellow Green Blue voltage white type colorless transparent cap. would like board terminals, please part number when ordering. However, this only applies gold contacts. Please inquire details. Also, would like mushroom button type board terminals, please position marked triangle. Indicators (indicator lamps) dia. projecting type Form square flat type flat type dia. projecting type square flat type flat type Splashproof type (IP65) Part ACEL2200 ACEL3200 ACEL4200 White Opaque Notes) following combinations numbers letters entered square symbol indicate voltage pushbutton color. Pushbutton color AC/DC AC/DC Orange Yellow Green Blue voltage white type colorless transparent cap. There mushroom button type indicator (indicator lamp). would like board terminals, please part number when ordering. Series: dia. types (ACEL, ACBL, ACSL, ACKL) Ordering block items Please refer configuration diagram below. dia. mounting hole type illuminated pushbutton switch configuration diagram Color block ACEL1 Operation block ACEL12 ACDL1861 Lamp holder ACDL1870 Switch block ACCL Assembly Notes: LEDs, please page accessories maintenance parts. Indicators also combined shown above. Please dedicated indicator switch block. pushbutton switch (non-illuminating), please combine color cap, operation block switch block from blocks above. Please dedicated dia. mushroom button type dia. mushroom button operation block. Pushbutton switches (non-illuminated types transparent buttons However, mushroom button type clear.) dia. projecting type square flat type flat type dia. mushroom button type dia. mushroom button type Color Form poles Contact material Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Orange Yellow Green dia. projecting type Single pole Double poles Single pole Transparent button square flat type Double poles Single pole flat type Double poles Single pole dia. Double poles Mushroom button Single pole dia. Double poles Splashproof type (IP65) Momentary Alternate Part Part ACBL22510 ACBL22710 ACBL22520 ACBL22720 ACBL22610 ACBL22810 ACBL22620 ACBL22820 ACBL32510 ACBL32710 ACBL32520 ACBL32720 ACBL32610 ACBL32810 ACBL32620 ACBL32820 ACBL42510 ACBL42710 ACBL42520 ACBL42720 ACBL42610 ACBL42810 ACBL42620 ACBL42820 ACBL0251K ACBL0271K ACBL0252K ACBL0272K ACBL0261K ACBL0281K ACBL0262K ACBL0282K ACBL5251K ACBL5271K ACBL5252K ACBL5272K ACBL5261K ACBL5281K ACBL5262K ACBL5282K Blue White Black Notes) following letter indicating pushbutton color entered place symbol. Pushbutton color Product white type colorless transparent cap. mushroom button type available orange. would like board terminals, please part number when ordering. However, this only applies gold contacts. Please inquire details. Series: dia. types (ACEL, ACBL, ACSL, ACKL) Selector switches square flat type flat type dia. flat type 2-notch manual reset 3-notch manual reset 2-notch manual reset type Form poles Single pole Contact material Splashproof type (IP65) Part ACSL32153 ACSL32154 ACSL32163 ACSL32164 ACSL42153 ACSL42154 ACSL42163 ACSL42164 ACSL52153 ACSL52154 ACSL52163 ACSL52164 square flat type flat type dia. flat type Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Single pole Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Single pole Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) 3-notch manual reset type Form square flat type flat type dia. flat type poles Double poles Contact material Splashproof type (IP65) Part ACSL32363 ACSL32364 ACSL42363 ACSL42364 ACSL52363 ACSL52364 Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Note: would like board terminals, please part number when ordering. However, this only applies gold contacts. selector switches square flat type flat type dia. flat type 2-notch manual reset type Splashproof type (IP65) Form poles Contact material removed position Part ACKL3211131 ACKL3211141 ACKL3211231 ACKL3211241 ACKL4211131 ACKL4211141 ACKL4211231 ACKL4211241 ACKL5211131 ACKL5211141 ACKL5211231 ACKL5211241 removed position Part ACKL3212131 ACKL3212141 ACKL3212231 ACKL3212241 ACKL4212131 ACKL4212141 ACKL4212231 ACKL4212241 ACKL5212131 ACKL5212141 ACKL5212231 ACKL5212241 removed both positions Part ACKL3213131 ACKL3213141 ACKL3213231 ACKL3213241 ACKL4213131 ACKL4213141 ACKL4213231 ACKL4213241 ACKL5213131 ACKL5213141 ACKL5213231 ACKL5213241 square flat type flat type dia. flat type Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Single pole Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Single pole Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Single pole Series: dia. types (ACEL, ACBL, ACSL, ACKL) 2-notch automatic reset type Splashproof type (IP65) Form poles Contact material removed position Part ACKL3221131 ACKL3221141 ACKL3221231 ACKL3221241 ACKL4221131 ACKL4221141 ACKL4221231 ACKL4221241 ACKL5221131 ACKL5221141 ACKL5221231 ACKL5221241 square flat type flat type dia. flat type Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Single pole Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Single pole Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Single pole 3-notch manual reset type Splashproof type (IP65) Form poles Contact material removed positions Part ACKL3237231 ACKL3237241 ACKL4237231 ACKL4237241 ACKL5237231 ACKL5237241 square flat type flat type dia. flat type Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Double poles Note: would like board terminals, please part number when ordering. However, this only applies gold contacts. Ordering block items Selector switches with dia. mounting holes selector switches consist blocks below. Block items given separate page. Selector switch operation block ACSL12 selector switch operation block ACKL12 Switch block (for non-illuminating pushbutton switches) ACCL26 Assembly Series: dia. types (ACEL, ACBL, ACSL, ACKL) SPECIFICATIONS Contact rating Gold-clad contact Load Resistive load Minute load Rating AC/DC* Note) usable range minute load indicated asterisk fluctuate depending usage conditions type load. Silver contact Load Resistive load Induction load* rating rating Note) values induction load indicated asterisk follows: alternating current induction load 0.7, direct current induction load less. rating Rated operating voltage Operating voltage range DC±5% Rated current Approx. 50,000 hours (with full direct current lighting initial intensity) life (reference value) Equivalence circuit Lighted colors Anode side (X1) Cathode side AC/DC AC/DC±10% Red, orange, yellow, green, blue, opaque AC/DC AC/DC±10% (X2) Note) current limiting resistor protective diode built into bulb. Characteristics Item Standard usage condition Contact resistance Insulation resistance Dielectric strength Vibration resistance Shock resistance Switch section Illuminating section Malfunctioning Durability Malfunctioning Mechanical Expected life Electrical Protective construction Terminal shape Specifications Ambient temperature: +55°C (Not freezing) (Storage temperature: +80°C) Relative humidity: Max. (initial) Min. (500 megger) Between charging part ground: 2,500 min. Between terminals with unlike poles: 2,500 min. Between terminals with like poles: 1,000 min. Between charging part ground: 2,500 min. double amplitude 1,000 m/s2 (approx. m/s2 (approx. Momentary: Min. times, switching frequency 1,200 times/hr. Alternate: Min. times, switching frequency 1,200 times/hr. Selector switch (incl. those with keys): Min. times, switching frequency 1,200 times/hr. Momentary: Min. times, switching frequency 1,200 times/hr. Alternate: Min. times, switching frequency 1,200 times/hr. Selector switch (incl. those with keys): Min. times, switching frequency 1,200 times/hr. Splashproof type IP65 (IEC60529) terminal with that doubles soldering Series: dia. types (ACEL, ACBL, ACSL, ACKL) DIMENSIONS (unit: Illuminated pushbutton switches, indicators, pushbutton switches dia. projecting type square flat type (Indicators) flat type (Pushbutton switches) dia. mushroom button type dia. mushroom button type (Tight mounting type illuminated pushbutton switches) Whirl-stop plate 1.45 dia. mushroom button type Panel thickness: Rubber washer Label position 1.45 LOCK 1.45 Lock Lock Rubber washer Panel thickness: 7.85 Stop plate 13.5 10.5 LOCK 13.5 10.5 LOCK LOCK 15.8 terminal width: 0.5t 17.8 display position terminal width: 0.5t 17.8 dia. projecting type square flat type External dimensions flat type dia. mushroom button type 23.5 dia. dia. mushroom button type dia. dia. Notes) Pushbutton switches have only contact terminals, have lamp terminals. Indicators have only lamp terminals, have contact terminals. There mushroom button type indicator. Please inquire regarding external dimensions board terminal type. WIRING DIAGRAM (BOTTOM VIEW) (Illuminated pushbutton switches) Lamp terminal Lamp terminal (Indicators) (Pushbutton switches) Lamp terminal Lamp terminal (Single pole types have only right terminal.) Notes: "X2" terminals have terminals order make cross wiring easy. "X2" terminals connected internally. (Single pole types have only right terminal.) 15.8 Series: dia. types (ACEL, ACBL, ACSL, ACKL) Tight mounting type, mounting hole diagram, recommended minimum mounting pitch Change tight mounting type from production March, 2002. dia. projecting square flat types 16.2 +0.2 flat type dia. mushroom button type Min. 28.5 16.2+0.2 dia. dia. mushroom button type Min. 16.2+0.2 dia. dia. 16.2 +0.2 dia. Min. 28.5 Note) Operability should taken into consideration when deciding mounting pitch. Selector switches/Key selector switches Selector switches Wiring diagram (BOTTOM VIEW) Whirl-stop plate Min. 1.45 square flat type flat type dia. flat type Lock Rubber washer Panel thickness: LOCK square flat type External dimensions flat type dia. flat type 13.5 10.5 (Single pole types have only right terminal.) LOCK dia. terminal width: 0.5t 17.8 selector switches Wiring diagram (BOTTOM VIEW) Whirl-stop plate 1.45 15.8 square flat type flat type dia. flat type Lock Rubber washer Panel thickness: LOCK square flat type External dimensions flat type dia. flat type 25.1 13.5 10.5 (Single pole types have only right terminal.) LOCK terminal width: 0.5t 17.8 15.8 Series: dia. types (ACEL, ACBL, ACSL, ACKL) Tight mounting type, mounting hole diagram, recommended minimum mounting pitch Change tight mounting type from production March, 2002. dia. projecting square flat types 16.2 +0.2 mounting pitch type, mounting hole diagram, recommended minimum mounting pitch mounting hole diagram below applies products production February 2002. mounting pitch type 16.2+0.2 dia. flat type dia. 16.2 +0.2 dia. Note) Operability should taken into consideration when deciding mounting pitch. Note) Operability should taken into consideration when deciding mounting pitch. Internal circuit diagram Notch specifications Contact arrangement (left) Notch positions (TOP VIEW) (center) (right) Form Left contact Right contact Left contact Right contact -2-notch Form Left contact Right contact Left contact Right contact Left contact Right contact -3-notch Form Series: dia. types (ACHL) Emergency pushbutton switches Series (mounting hole dia. type) FEATURES Equipped with safety lock mechanism that prevents emergency stops caused erroneous operation Safety lock mechanism safety lock mechanism used which contact does move until pushbutton completely locked. Because contact does operate unless button been pressed down, there danger machine suddenly stopping because malfunction caused something coming contact with button, loss from such situations. Forced contact separation mechanism used contact mechanism. received marking. Forced contact separation mechanism mechanism designed that button operation force used, contact separation force. Therefore, circuit will shut perfectly even problem happens occur such contact welding shut. (Conforms EN60947-5-1 Annex certified. Conforms (European) standards. (Meets EN60947-1, EN60947-5-1, DEMKO standards.) button diameters available, dia. button type dia. button type RoHS Directive compatibility information http://www.nais-e.com/ ORDERING INFORMATION Emergency pushbutton switches (push lock, turn reset) ACHL Mounting holes shape Mounting hole dia. Protective construction/Contact method Splashproof type (IP65)/Form contact, forced contact separation type poles Single pole Double poles Contact material Standard type (Silver contact) Color shapes dia. dia. Color color TYPES Mounting hole Contact arrangement Form dia. Form Color dia. dia. dia. dia. Splashproof type (IP65)/Form contact, forced contact separation type Part ACHL25111R ACHL25112R ACHL25211R ACHL25212R Note: Emergency pushbutton switches sold block items. Series: dia. types (ACHL) SPECIFICATIONS Contact rating Load Resistive load Induction load* rating rating 0.22 Characteristics Item Standard usage condition Contact resistance Insulation resistance Dielectric strength Vibration resistance Shock resistance Expected life Switch section Malfunctioning Durability Malfunctioning Mechanical Electrical Specifications Ambient temperature: +55°C (Not freezing) (Storage temperature: +80°C) Relative humidity: Max. (initial) Min. (500 megger) Between charging part ground: 2,500 min. Between terminals with unlike poles: 2,500 min. Between terminals with like poles: 1,000 min. double amplitude 1,000 m/s2 (approx. m/s2 (approx. Min. Min. 105, switching frequency 1,200 times/hr. Splashproof type IP65 (IEC 60529) terminal with that doubles soldering Note) values induction load indicated asterisk follows: alternating current induction load 0.7, direct current induction load less. Protective construction Terminal shape DIMENSIONS (unit: dia. button type Panel mounting dimension 16.2+0.2 dia. Whirl-stop fitting LOCK Lock Rubber washer Panel thickness: min. min. 13.5 10.5 R15.5 Wiring Diagram (BOTTOM VIEW) mark side .1(NC) .1(NC) dia. 15.8 Terminal width (Tab terminal shape doubles soldering use) 17.8 .2(NC) .2(NC) Note) Form contact type contact only left side. dia. button type Panel mounting dimension R15.5 dia. 15.8 13.5 10.5 17.8 min. .2-+0.2 min. terminal width display position Series: dia. types (ACZL) Buzzers Series (mounting hole dia. type) FEATURES user select continuous buzzing sound, long intermittent sound, short intermittent sound, using slide switch inside terminal part. RoHS Directive compatibility information http://www.nais-e.com/ TYPES Mounting hole dia. Shape panel front Usage voltage AC/DC ±10% Part ACZL4100 Notes: user select continuous buzzing sound, long intermittent sound, short intermittent sound, using slide switch inside terminal part. Buzzers sold block items. SPECIFICATIONS Rated insulating voltage Rated operating voltage Current consumption Sound pressure Sound frequency Buzzer repetitions Standard usage conditions Insulation resistance Dielectric strength Vibration resistance (malfunctioning) Shock resistance (durability) Expected life Protective construction Terminal shape AC/DC AC/DC ±10% Min. continuous sound rated voltage) ±500 Long intermittent: times/min. ±10% Short intermittent: times/min. ±10% Ambient temperature: +55°C (Not freezing) Relative humidity: Min. (500 megger) Between charging non-charging parts: 1,000 min. unilateral amplitude 1,000 m/s2 (approx. 1,000 hours min. Enclosed type (JEM 1030) terminal with that doubles soldering DIMENSIONS (unit: Panel mounting dimension 16.2+0.2 dia. Panel thickness: Rubber washer Lock 7.85 LOCK 15.7 Stop plate Label position R15.5 Terminal width Wiring Diagram (BOTTOM VIEW) 21.0 dia. 18.0 15.8 Input terminal (X1) Input terminal (X2) Continu- Inter- Interous mittent mittent sound sound sound (Long) (Short) 24.0 13.5 10.5 36.0 display position 17.8 Continuous/intermittent sound slide switch (internal switch) Accessories maintenance items dia.) Accessories maintenance items dia.) Ring tightener Part Specifications Unit ACDL1800 Metal RoHS Directive compatibility information http://www.nais-e.com/ This tool convenient tightening lock nuts used when mounting unit panel. When tightening rings, torque should between 0.68 0.88 (7.0 Lamp replacement tool Part Specifications Unit ACDL1802 illuminated pushbuttons indicators pcs. This tool used replace lamps when LEDs being installed removed. Removal tool Part Specifications Unit ACDL1804 Metal This tool used pull operating parts (color cap, inscribed plate, holder) illuminated pushbuttons, indicators, pushbutton switches. LEDs (parts maintenance) illuminated pushbuttons indicators (indicator lamps), built-in. These LEDs should ordered only spares required. asterisk pack part number where letter indicate lamp color inserted. Part Rated operating voltage Rated current Unit ACDL1861 DC±5% ACDL1861 AC/DC±10% pcs. ACDL1861 AC/DC±10% Note) following number/letter combinations indicating voltage pushbutton color should entered square indicated asterisk after part number. Pushbutton color AC/DC AC/DC Orange Yellow Green Blue voltage White Opaque Maintenance parts should installed engineer with specialized expertise electrical components. When placing orders, please specify number marketing units. Accessories maintenance items dia.) Protective cover DIMENSIONS (unit: dia. square (ACDL1810) (ACDL1811) 23.5 This cover designed prevent erroneous operation. cover opens 180°, closes means return spring. Protective construction: Spray-resistant type (IP65) 10.5 23.5 45.5 min. 10.5 min. Return spring min. Type Part Unit dia./ square ACDL1810 ACDL1811 pcs. Protective cover installation diagram Dustproof cover DIMENSIONS (unit: dia. (ACDL1812) dia. Panel thickness: square (ACDL1813) (ACDL1814) 45.5 min. Panel thickness: minimum installation pitch will different dustproof cover being used. Ambient usage temperature: +55°C Material: Elastomer (front/transparent) polypropylene (back/nontransparent black) Waterproof seal dustproof cover Waterproof seal dustproof cover Waterproof seal dustproof cover Dustproof cover installation diagram (Minimum mounting pitch) dia. square type type 16.2+0.2 dia. 16.2+0.2 dia. Note) When deciding mounting pitch, make sure cover enough room operate properly. Type Part Unit dia. ACDL1812 square ACDL1813 pcs. ACDL1814 Maintenance parts should installed engineer with specialized expertise electrical components. When placing orders, please specify number marketing units. Accessories maintenance items dia.) Insulating terminal cover Part Specifications Unit ACDL1850 Opaque nylon material DIMENSIONS (unit: mark side This terminal cover made opaque nylon material. Note) When wiring terminal, insert lead into hole insulating terminal cover before soldering Dimension inner back panel when mounting insulating terminal cover: Mounting hole plug (rubber) Part Specifications Unit ACDL1820 Nitrile rubber (black) Protective construction: IP65 pcs. DIMENSIONS (unit: Mounting hole dia. 16.5 dia. Mounting hole plug (metal) Part Specifications Unit ACDL1821 Made metal Protective construction: IP65 pcs. DIMENSIONS (unit: Mounting hole Lock 17.8 dia. Seal Inscribed plate (maintenance part) Shape Part Unit Round ACDL1830 Square ACDL1831 Rectangular ACDL1832 pack plates) dia. mushroom button type ACDL1835 dia. mushroom button type ACDH1836 Color: Opaque Material: Methacrylic resin ACDL1835 ACDH1836 mushroom buttons illuminating pushbuttons. Maintenance parts should installed engineer with specialized expertise electrical components. When placing orders, please specify number marketing units. 17.6 Cautions Series dia.) Cautions Mounting removing color inscribed plate Removing Grip grooved part color with removal tool (Part ACDL1804), pull towards remove operating parts (the color cap, inscribed plate holder). inscribed plate removed pushing color outward from back side, freeing grooved section that joins holder. plate inscribed surface, shown below, other side. Grooved section Joining grooves Cautions Series dia.) Press head remove from lamp housing. [Mounting LED] First, insert into lamp housing. Make sure been pressed firmly into lamp housing. (This done more easily using lamp replacement tool side which gripped.) Insert lamp replacement tool position lamp housing shown below, hold that position. Lamp housing Lamp replacement tool Precautions when mounting panel Inscribed surface Color Inscribed plate Holder Mounting Place inscribed plate holder, line grooves color holder, press them together. When doing this, make sure inscribed plate facing correct direction. After inscribed plate color have been mounted holder, insert assembled unit main unit, making sure faces correct direction. Precautions when mounting operating part (non-illuminated type) Like illuminated pushbutton switch, pushbutton switch (non-illuminated type) also inscribed plate. When mounting removing operating part, make sure plate mounted same that illuminated pushbutton switch. Mounting removing LEDs LEDs mounted removed from front panel, using lamp replacement tool, also done from back, removing switch block. Mounting removing from front panel [Removing LED] Insert lamp replacement tool lamp housing, turn slightly left while pressing lightly remove cap. tool inserted that insertion guide inside lamp housing facing same direction mark switch block, mounting base switch block will facing same direction insertion guide lamp housing. When these aligned correctly, turn tool right while pressing lightly install LED. Removing mounting removing switch block mounted removed without using tools switch block removed. Panel mounting tighten ring when mounting operation block panel, special tool (ring tightener, Part ACDL1800, sold separately), tighten ring torque between 0.68 0.88 (9.0 Using radio pliers tighten ring, tightening beyond required torque, damage ring, careful tighten correctly. Inscribed display With series manual operating illuminated pushbutton switches indicators (indicator lamps) with dia. mounting holes, internal inscribed plate engraved. range depth engraving shown below. Insertion inscribed film possible internal construction. Engraving dimensions series with dia. mounting hole Shape Round Square Plate prod. ACDL1830 Outer dimension 13.7 dia. Thickness Engraving depth Depth 11.8 dia. max. Depth 12.0 square max. Depth 18.0 12.0 max. Engraving range ACDL1831 13.7 square 19.7 13.7 Separate operation block switch block attach operation block panel hole from front panel. Then insert whirl-stop plate from back panel, tighten with lock nut. Finally, mount switch block. Mounting removing switch block Move lock lever switch block direction opposite arrow pull switch block operation block. When mounting switch block, align marks operation block switch block, move lever direction arrow lock switch block place. RectanACDL1832 gular Note) Material: Opaque methacrylic resin insert film other foreign substances between color inscribed plate. Precautions when working with blue green LEDs With illuminated pushbutton switches indicators (indicator lamps), already been installed, green blue LEDs being replaced, careful that static electricity comes direct contact with part metal frame around module that cutouts (see illustration below). static electricity applied this part, destroy element. When mounting main unit, special lamp replacement tool (Part ACDL1802) designed that purpose. Cautions Series dia.) instructions mounting removing LEDs, please Mounting removing LEDs". Area around (metal frame with cutout sections) Enlarged view (Special lamp replacement tool) ACDL1802 Product main unit Precautions when connecting wiring Terminals should soldered less than seconds, 260°C less than seconds, without applying external force. When doing this work, make sure soldering iron does come contact with switch itself, that, when connecting wiring, tensile force applied terminal. Avoid bending terminal subjecting excessive force. Non-corroding liquid resin flux should used. Handling insulating terminal cover Align marks main unit insulating terminal cover, insert cover. Note) When connecting wiring, insert lead into hole insulating terminal cover before soldering Connections Positive Lock connectors (made Co.) Easy Lock connectors (made Nichifu Co.) used terminals. table below shows recommended models connectors. Item Positive Lock connectors Co.) 175412-1 174778-1 1.25 174779-1 Easy Lock connectors Nichifu Co.) OSS0.3 62852F3 OSS1.25 62815F3 NET1-28-1P Terminal Housing When using illumination LEDs configured semiconductors, they used voltage exceeding maximum operating voltage, element deteriorate because irregular heat generation, causing noticeable drop intensity, discoloration, failure light, other problems. External noise, transient voltage, transient current applied circuit cause same types problems. With illuminated types that have rated voltage VDC, AC/DC, AC/DC particular, following items should given careful consideration when using LED. Power supplies blocks with rated voltage AC/DC, AC/DC blocks used with rated voltage AC/DC, AC/DC both alternating direct current, either alternating current direct current power supplies used with these. voltage used should within range ±10% rated voltages both alternating direct current. using range ±5%) Direct current power supplies Constant-voltage power supplies switching other power supplies These ideal power supplies. They should used within operating voltage range block. Batteries When charging, immediately after charging, please aware that voltage exceed operating voltage some cases. Make sure voltage within range ±10% rated voltage (±5% rated voltage Full-wave rectification Since both alternating direct current used, there need rectification using diode bridge. Please aware that, full-wave rectification using diode bridge used, rectifying diode cause voltage drop, resulting decreased intensity. Single-phase half-wave rectification This appropriate power supply block. recommend using direct current constant-voltage power supply. Noise External noise cause element deteriorate, causing noticeable drop intensity, discoloration, failure light, other problems. situations where this occur, preventive measures noted below should considered. element such element surge absorber should used prevent adverse effects caused noise. (Circuit example Altenating current cases with adapter, etc. with adapter, etc. Relay, coil, solenoid, etc. Corrective action dark illumination Leakage current Leakage current from non-contact switch that lights block from contact protective circuit cause block light faintly some cases even output off. this happens, following corrective steps should taken. block (direct-current type) being lighted transistor output type non-contact switch, insert dividing resistor parallel with block. (Circuit example) Leakage current when output Dividing resistor block (alternating-current type) being lighted TRIAC output type non-contact switch built into element, insert element parallel with block. (Circuit example) (Reference value) 0.1µF Leakage current with adapter, etc. block (alternating-current type) being lighted relay output which element that protects contact been connected parallel, insert element parallel with block. (Circuit example) (Reference value) 0.1µF with adapter, etc. Leakage current Induction When using units with adaptors, induction from surrounding line cause lamp light dimly. Corrective action: Insert element parallel with block. line (Reference value) 0.1µF (Reference value) 0.1µF (Circuit example Directing current cases (Reference values) Current capacitance diode: value equivalent higher than that operating current solenoid other components Reverse dielectric strength Diode diode: Approx. times operating voltage solenoid other components with adapter, etc. Induced current Relay, coil, solenoid, etc. Cautions Series dia.) Handling Usage Precautions Aggregate tight mounting Please aware that heat caused aggregate tight mounting indicator lamps illuminated pushbutton switches continuously lamps cause ambient temperature exceed prescribed amount. Measures must taken ventilate lower operation voltage mounting panel metal product being used sealed control panel. Replacement buttons (illuminating non-illuminating) replace alternate type buttons (illuminating non-illuminating) when they locked. (Replacing while locked might damage internal mechanism.) must release locks before replacing. Storage place Please within working ambient temperature humidity ranges given ratings display. When using location where oil, water dirt present, install dust cover that foreign substances cannot enter sliding part pushbutton. Contact (microswitch) When using identical (normal close) (normal open) microswitch contacts, connect wrong voltage wrong type power supply. Doing will cause dead short. resistance product been evaluated with commonly used standard machining cooling oil. Please inquire about other oils, since some special oils possible. Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) Illuminated pushbutton, non-illuminated pushbutton, selector, selector switches Rheinland Series (mounting hole dia. type) Bright, clear illumination (ultra-high intensity used) Separate mounting model features removable lock lever Addition mushroom button type Nice, light switching feel. Light operation load snap action mechanism. Short stroke type. Relationship between operation load stroke (Mounting hole dia. type: Form contact momentary action) Operation load Stroke (mm) FEATURES Bright, clear illumination Uses brilliantly illuminating LEDs that much brighter than incandescent bulbs. Brightness greatly increased vastly improved recognition safety. Yellow green particularly easy distinguish. Makers especially concerned about product liability laws worker safety sanitation calling machines that designed manufactured based ISO12100 series international safety standards (general regulations governing basic conceptual design machine safety). With ISO12100 series, manmachine interface must designed that status machine recognized clearly correctly anyone running machine, without special training expertise. that reason, display lamp colors standardized under IEC60073, IEC60204-1 other standards cited ISO12100 series, covered standards well. illumination type meets safety needs such these, beyond. Note) IEC60073: 0448 Colors Display Units Operation Devices IEC60204-1: 9960-1 Safety Machines Electrical Units Machines Display lamp colors meanings indicating machine status (taken from International Electrical Standards Conference IEC-60073 60204-1) Color Meaning Emergency Explanation Hazardous situation Problem status/urgent critical situation Normal status Displays status action required operator other status; used when using red, yellow, green, blue might interpreted erroneously. Operator action Action appropriate hazardous situation Visual monitoring (or) intervention appropriate Obligatory action Yellow Caution Green Normal Blue Obligatory Stroke: Mechanical life (mounting hole dia. type) Momentary type: Min. (Twice that earlier products) Alternate type: Min. times better than previous) Removal/installation type with lock lever system. Smooth installation possible. easy install tight spaces maintenance easy. Operation efficiency greatly increased since surface installation wiring operations carried separately. Mounting hole dia. type Lock lever White Neutral Visual monitoring Power consumption greatly reduced type). power consumption been reduced type (mounting hole dia. type). Continuous illumination with need replacement years (50,000 hours). Rated current Mounting hole Mounting hole dia. type dia. type previous model) previous model) type Products available illuminated colors: red, orange, yellow, green, blue, white. Mushroom button type easier operation. Wiring work simplified thanks screw terminal type. Splashproof type protective construction (IP65). Conforms 60529. Safety standard certified (excluding buzzer). Conforms standard (excluding buzzer), received marking. Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) Durability Thermoplastic materials used durability outer casing installation points. Contacts made cadmium-free material. RoHS Directive compatibility information http://www.nais-e.com/ ORDERING INFORMATION Illuminated pushbutton switches (LED illumination) indicators (indicator lamps) ACEL Illumination type type Mounting holes flange shapes Mounting hole Flange shape dia. 25.8 dia. projecting type (illuminated pushbutton switches only) dia. 25.8 dia. flat type dia. 25.8 square flat type (With mushroom button only) dia. dia. Protective construction Splashproof type (IP65) poles operating characteristics Indicator (indicator lamp) Single-pole Form momentary Double-pole Form momentary Contact material Indicator (indicator lamp) contact) Standard type (Silver alloy contact) voltages pushbutton colors Pushbutton color AC/DC AC/DC Orange Yellow Color Green Blue Single-pole Form alternate Double-pole Form alternate Low-level circuit type (Gold-clad contact) voltage White (LED: opaque) Terminal shape mounting dimensions Nil: Standard mounting Terminal board standard mounting (only gold contact) Screw terminal Form only) Color types Nil: Regular Mushroom button type There mushroom button type indicator (indicator lamp). Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) Pushbutton switches (non-illuminated types transparent buttons) ACBL Mounting holes flange shapes Mounting hole Flange shape dia. 25.8 dia. projecting type dia. 25.8 dia. flat type dia. 25.8 square flat type (With mushroom button type) Mounting hole Flange shape dia. dia. Protective construction Splashproof type (IP65) poles operating characteristics Single-pole Form momentary Double-pole Form momentary Contact material Standard type (Silver alloy contact) Types color caps Transparent button Pushbutton colors Transparent button (Mushroom button: clear) Orange Yellow Green Blue White Black Mushroom button Single-pole Form Alternate Double-pole Form Alternate Low-level circuit type (Gold-clad contact) Note: Mushroom button type available orange. Terminal shape mounting dimensions Nil: Solderable terminal, standard mounting Terminal board standard mounting (only gold contact) Screw terminal Form only) Selector switches ACSL Mounting holes flange shapes Mounting hole Flange shape dia. 25.8 dia. flat type dia. 25.8 round square type Protective construction Splashproof type (IP65) Operation methods 2-notch manual reset 3-notch manual reset (Double poles only) poles Single pole (2-notch only) Contact material Standard type (Silver contact) Note) Manual reset: Switch rotated turn remains when released. Double poles Low-level circuit type (Gold-clad contact) Terminal shape Nil: Terminal with that doubles soldering Terminal board Screw terminal Form only) Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) selector switches ACKL Mounting holes flange shapes Mounting hole Flange shape dia. 25.8 dia. flat type dia. 25.8 round square type Protective construction Splashproof type (IP65) Operation methods removal positions 2-notch manual reset: position 2-notch manual reset: position 2-notch manual reset: Both positions 3-notch manual reset single pole; double poles only) (Key removed position) poles Single pole Double poles Contact material Standard type (Silver contact) Low-level circuit type (Gold-clad contact) type Standard Terminal shape Nil: Terminal with that doubles soldering Terminal board Screw terminal Form only) Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) TYPES Illuminated pushbutton switches (LED illumination) 25.8 dia. projecting type 25.8 dia. flat type 25.8 square flat type dia. mushroom button type Splashproof type (IP65) Momentary Alternate Part Part ACEL6211 ACEL6231 ACEL6212 ACEL6232 ACEL6221 ACEL6241 ACEL6222 ACEL6242 ACEL7211 ACEL7231 ACEL7212 ACEL7232 ACEL7221 ACEL7241 ACEL7222 ACEL7242 ACEL8211 ACEL8231 ACEL8212 ACEL8232 ACEL8221 ACEL8241 ACEL8222 ACEL8242 ACEL9211 ACEL9231 ACEL9212 ACEL9232 ACEL9221 ACEL9241 ACEL9222 ACEL9242 White Opaque Form poles Contact material Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) 25.8 dia. projecting type Single pole Double poles Single pole 25.8 dia. flat type Double poles Single pole 25.8 square flat type Double poles dia. mushroom button type Single pole Double poles Notes) following combinations numbers letters entered square symbol indicate voltage pushbutton color. Pushbutton color AC/DC AC/DC Orange Yellow Green Blue voltage white type colorless transparent cap. would like board terminals, please part number when ordering. (However, would like mushroom button type board terminals, please position marked triangle.) would like screw terminal Form only), please part number when ordering. (However, would like mushroom button type screw terminal Form only), please position marked triangle.) However, board terminal only applies gold contacts. Indicators (indicator lamps) 25.8 dia. flat type Form 25.8 square flat type Splashproof type (IP65) Part ACEL7200 ACEL8200 White Opaque 25.8 dia. flat type 25.8 square flat type Notes) following combinations numbers letters entered square symbol indicate voltage pushbutton color. Pushbutton color AC/DC AC/DC Orange Yellow Green Blue voltage white type colorless transparent cap. would like board terminals, please part number when ordering. There mushroom button type indicator (indicator lamp). There screw terminal type. Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) Pushbutton switches (non-illuminated types transparent buttons) 25.8 dia. projecting type 25.8 dia. flat type 25.8 square flat type dia. mushroom button type Splashproof type (IP65) Momentary Alternate Part Part ACBL62510 ACBL62710 ACBL62520 ACBL62720 ACBL62610 ACBL62810 ACBL62620 ACBL62820 ACBL72510 ACBL72710 ACBL72520 ACBL72720 ACBL72610 ACBL72810 ACBL72620 ACBL72820 ACBL82510 ACBL82710 ACBL82520 ACBL82720 ACBL82610 ACBL82810 ACBL82620 ACBL82820 ACBL9251K ACBL9271K ACBL9252K ACBL9272K ACBL9261K ACBL9281K ACBL9262K ACBL9282K Green Blue White Black Color Form poles Contact material Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Orange Yellow 25.8 dia. projecting type Single pole Double poles Single pole Transparent button 25.8 dia. flat type Double poles Single pole 25.8 square flat type Double poles Single pole Mushroom button dia. Double poles Notes) following letter indicating pushbutton color entered place symbol. Transparent button Pushbutton color Part white type colorless transparent cap. mushroom button type clear. mushroom button type available orange. would like board terminals, please part number when ordering. would like screw terminal Form only), please part number when ordering. However, board terminal only applies gold contacts. Selector switches 25.8 dia. flat type 25.8 round square type 2-notch manual reset 3-notch manual reset 2-notch manual reset type Form poles Single pole Contact material Splashproof type (IP65) Part ACSL62153 ACSL62154 ACSL62163 ACSL62164 ACSL72153 ACSL72154 ACSL72163 ACSL72164 25.8 dia. flat type 25.8 round square type Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Single pole Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Note: screw terminal Form only) terminals board also possible. Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) 3-notch manual reset type Form 25.8 dia. flat type 25.8 round square type poles Double poles Contact material Splashproof type (IP65) Part ACSL62363 ACSL62364 ACSL72363 ACSL72364 Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Note: screw terminal Form only) terminals board also possible. selector switches 25.8 dia. flat type 25.8 round square type 2-notch manual reset type Splashproof type (IP65) Form poles Contact material removed position Part ACKL6211131 ACKL6211141 ACKL6211231 ACKL6211241 ACKL7211131 ACKL7211141 ACKL7211231 ACKL7211241 removed position Part ACKL6212131 ACKL6212141 ACKL6212231 ACKL6212241 ACKL7212131 ACKL7212141 ACKL7212231 ACKL7212241 removed both positions Part ACKL6213131 ACKL6213141 ACKL6213231 ACKL6213241 ACKL7213131 ACKL7213141 ACKL7213231 ACKL7213241 25.8 dia. flat type 25.8 round square type Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Single pole Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Single pole Note: screw terminal Form only) terminals board also possible. 3-notch manual reset type Splashproof type (IP65) Form poles Contact material removed positions Part ACKL6237231 ACKL6237241 ACKL7237231 ACKL7237241 25.8 dia. flat type 25.8 round square type Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Standard type (Silver contact) Double poles Low-level circuit type (Gold-clad contact) Double poles Note: screw terminal Form only) terminals board also possible. Ordering block items dia. mounting hole type illuminated pushbutton switches dia. mounting hole type illuminated pushbutton switches consist four blocks below. Block items given separate page. Color block ACEL1 Operation block ACEL12 (For mushroom button) ACEL326 ACDL1862 Switch block (for illuminated pushbutton switch) ACCL12 Assembly Notes: LED, please page accessories maintenance parts. Indicators (indicator lamps) also combined shown above. Please dedicated indicator color switch block. pushbutton switch (non-illuminating), please combine color cap, operation block switch block from blocks above. Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) Selector switches with dia. mounting holes selector switches Selector switches with dia. mounting holes selector switches consist blocks below. Block items given separate page. Selector switch operation block ACSL12 selector switch operation block ACKL12 Switch block (for non-illuminating pushbutton switches) ACCL22 Assembly SPECIFICATIONS Contact rating Gold-clad contact Load Resistive load Minute load Rating AC/DC* Note) usable range minute load indicated asterisk fluctuate depending usage conditions type load. Silver contact Load Resistive load Induction load* rating rating Note) values induction load indicated asterisk follows: alternating current induction load 0.7, direct current induction load less. rating Rated operating voltage AC/DC AC/DC Operating voltage range DC±5% AC/DC±10% AC/DC±10% Rated current Lighted colors Red, orange, yellow, opaque Green, blue Red, orange, yellow, green, blue, opaque Note) current limiting resistor protective diode built into bulb. Characteristics Item Standard usage condition Contact resistance Insulation resistance Dielectric strength Vibration resistance Shock resistance Switch section Illuminating section Malfunctioning Durability Malfunctioning Mechanical Expected life Electrical Protective construction Terminal shape Specifications Ambient temperature: +60°C (Not freezing) illumination, however, ambient temperature +50°C. (Storage temperature: +80°C) Relative humidity: (with condensation) Max. (initial) Min. (500 megger) Between charging part ground: 2,500 min. Between terminals with unlike poles: 2,500 min. Between terminals with like poles: 1,000 min. Between charging part ground: 2,500 min. double amplitude 1,000 m/s2 (approx. m/s2 (approx. Momentary: Min. times, switching frequency 1,200 times/hr. Alternate: Min. times, switching frequency 1,200 times/hr. Selector switch (incl. those with keys): Min. times, switching frequency 1,200 times/hr. Momentary: Min. times, switching frequency 1,200 times/hr. Alternate: Min. times, switching frequency 1,200 times/hr. Selector switch (incl. those with keys): Min. times, switching frequency 1,200 times/hr. Splashproof type IP65 (IEC60529) terminal with that doubles soldering Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) DIMENSIONS (unit: Illuminated pushbutton switches, indicators, pushbutton switches photograph shows illuminated pushbutton switch. 25.8 dia. projecting type 25.8 dia. flat type 25.8 square flat type dia. mushroom button type (Indicators) (Pushbutton switches) (Illuminated pushbutton switches) Retaining plate 4.85 LOCK 11.35 1.95 Panel thickness: 23.2 25.4 25.8 dia. projecting/flat type 25.8 square flat type dia. mushroom button type Lock Rubber washer 11.7 18.2 16.2 25.8 terminal width (Solderable): 0.5t 26.2 Notes) Pushbutton switches have only contact terminals, have lamp terminals. Indicators have only lamp terminals, have contact terminals. There mushroom button type indicator. There screw terminal indicator (indicator lamp). (Projecting type) terminal width 13.1 11.7 16.2 26.2 display position Panel mounting dimension 22.3+0.4 dia. WIRING DIAGRAM (BOTTOM VIEW) mark side Lamp terminal Lamp terminal Notes) mounting pitch values above illustration applicable when cluster adhesion mounting used. Operability other factors should taken into consideration when mounting pitch decided. terminals that double soldering: there terminal cover, allow least vertical horizontal directions. there terminal cover, allow least vertical direction more horizontal direction. Same models except mushroom button screw terminal types. Notes) Pushbutton switches have only contact terminals, have lamp terminals. Indicators have only lamp terminals, have contact terminals. Form contact type only center terminal. Form contact type only terminal right side terminal left side. (There center terminal.) Mushroom button type min. 22.3+0.4 dia. Screw terminal type 22.3+0.4 dia. min. Note) Operability should taken into consideration when deciding mounting pitch. Series: dia. types (ACEL, ACBL, ACSL, ACKL, ACZL) Selector switches/Key selector switches Selector switches Retaining plate LOCK 25.8 dia. flat type 25.8 round square type External dimensions 25.8 dia. type 25.8 round square type Lock Rubber washer Panel thickness: 17.5 11.7 4.85 18.2 16.2 25.8 terminal width (Solderable): 0.5t 26.2 selector switches Panel thickness: Rubber washer Lock LOCK 25.8 dia. flat type 25.8 round square type terminal width (Solderable): 0.5t 18.2 display position 16.2 25.0 26.2 External dimensions 25.8 dia. flat type 25.8 round square type Retaining plate 25.8 37.0 10.5 11.7 36.0 both selector switches selector switches/ WIRING DIAGRAM (BOTTOM VIEW) Mounting hole diagram same previous page illuminated pushbutton switch. Note) Form contact type only center terminal. Form contact type only terminal right side terminal left side. (There center terminal.) Internal circuit diagram (common Selector switches selector switches) Notch specifications Contact arrangement (left) Notch positions (TOP VIEW) (center) 4.85 (right) Form Left contact Right contact Left contact Right contact -2-notch Form Left contact Right contact Left contact Right contact Left contact Right contact -3-notch Form Series: dia. types (ACZL) Buzzers Series (mounting hole dia. type) FEATURES user select continuous buzzing sound, long intermittent sound, short intermittent sound, using slide switch inside terminal part. RoHS Directive compatibility information http://www.nais-e.com/ TYPES Mounting hole dia. Note: Buzzers sold block items. Shape panel front 25.8 square Usage voltage AC/DC ±10% Part ACZL8100 SPECIFICATIONS Rated insulating voltage Rated operating voltage Current consumption Sound pressure Sound frequency Buzzer repetitions Standard usage conditions Insulation resistance Dielectric strength Vibration resistance (malfunctioning) Shock resistance (durability) Expected life Protective construction Terminal shape AC/DC AC/DC ±10% Min. continuous sound rated voltage) ±500 Long intermittent: times/min. ±10% Short intermittent: times/min. ±10% Ambient temperature: +55°C (Not freezing) Relative humidity: Min. (500 megger) Between charging non-charging parts: 1,000 min. unilateral amplitude 1000 m/s2 (approx. 1,000 hours min. Enclosed type (JEM 1030) terminal with that doubles soldering DIMENSIONS (unit: Panel mounting dimension Panel thickness: Rubber washer Lock Retaining plate 22.3+0.4 dia. 15.7 LOCK terminal width: 0.5t Note) Wiring operation should token into consideration when deciding mounting pitch. Wiring diagram (BOTTOM VIEW) Continuous/intermittent sound slide switch mark side 25.8 11.7 display position 18.5 Label position Internal wiring completed input terminals (There polarity.) Intermittent Intermittent Continuous (short) (long) Internal wiring completed Accessories maintenance items dia.) Ring tightener Part Specifications Unit ACDL1801 Metal Accessories maintenance items dia.) RoHS Directive compatibility information http://www.nais-e.com/ This tool convenient tightening lock nuts used when mounting unit panel. When tightening rings, torque should between (10.0 12.0 Maintenance parts should installed engineer with specialized expertise electrical components. When placing orders, please specify number marketing units. Lamp replacement tool Part Specifications Unit ACDL1803 Rubber pcs. This rubber wrench that makes easy remove install LEDs. LEDs (parts maintenance) Part Rated operating voltage Rated current Unit ACDL1862 DC±5% ACDL1862 AC/DC±10% pcs. ACDL1862 AC/DC±10% Notes) asterisk mark rated current type indicates following: Red, orange, yellow, opaque Green, blue following combinations numbers letters entered square asterisk product number indicate voltage pushbutton color. Pushbutton color AC/DC AC/DC Orange Yellow Green Blue voltage White Opaque Insulating terminal cover Part Specifications Unit ACDL1851 Nylon pcs. This terminal cover made opaque nylon material. Note) When wiring terminal, insert lead into hole insulating terminal cover before soldering Accessories maintenance items dia.) Mounting hole plug (rubber) Part Specifications Unit ACDL1822 Rubber pcs. DIMENSIONS (unit: dia. This used fill holes (22.3 dia. that have been pre-cut spare panels. color black. dia. Mounting hole plug (metal) Part Specifications Unit ACDL1823 Metal pcs. DIMENSIONS (unit: 25.8 dia. Seal Lock This used fill unnecessary mounting holes panel. tightening torque lock nuts should lower. Protective construction: IP66 Inscribed plate (maintenance part) Shape Part Unit Round ACDL1833 Square ACDL1834 pack plates) Mushroom button type ACDL1837 This product opaque. ACDL1837 mushroom button illuminating pushbutton. Cautions Series dia.) Cautions Mounting removing color inscribed plate Removing plate Insert small screwdriver similar tool into grooved part color (the concave part flange), twist lightly remove operating parts (the color cap, inscribed plate holder). Removing operating parts Cautions Series dia.) Size engraving range internal inscribed plate Panel mounting Separate operation block switch block attach operation block panel hole from front panel. Then mount switch block. Mounting removing switch block Move lock lever switch block direction opposite arrow pull switch block operation block. When mounting switch block, align marks operation block switch block, move lever direction arrow lock switch block place. mark side Lock lever mark Inscribed plate inscribing film sizes Item 25.8 dia. projection/flat type 25.8 dia. square flat type Engraving range Engraving range *0.85mm 0.85mm 17.5mm Note) This using 25.8 dia. projecting type. (The engraving depth max.) Inscribed plate material: Opaque acrylic resin Applicable size inscribing film When color been removed from holder, inscribed plate removed. Remove color pushing from back section that joins color holder, direction color cap. Removing color Lock side Switch block Operation block 19.8mm 17.7mm Note) filter inside holder waterproof cannot removed. Mounting plate Place inscribed plate color cap, line with section joining color holder, press them together. When doing this, using 25.8 dia. type, make sure align whirl-stop projection inscribed plate with grooved part holder before inserting plate. this point, make sure inscribed plate facing correct direction. When using 25.8 dia. type Precautions when mounting panel tighten ring when mounting operation block panel, special tool (ring tightener, Part ACDL1801, sold separately), tighten ring torque between (12.0 Using radio pliers tighten ring, tightening beyond required torque, damage ring, careful tighten correctly. Collective mounting Series with dia. mounting hole installed removed using lock lever. lock lever easily locked released from back side, using screwdriver similar tool. This enables collective mounting, also makes possible remove units. Thickness: sheets, sheet. Caution: inscribing film built into unit. Film material: Polyester film (recommended) Sequence which inscribed plate inscribing film inserted 25.8 dia. projection/flat type (TOP mark side) Color Film Inscribed Holder plate Note) inscribing film built into unit. 25.8 square flat type (TOP mark side) Color Film Inscribed Holder plate Note) inscribing film built into unit. Make sure that inscribed plate facing correct direction. Color Inscribed plate Holder When using 25.8 dia. square type (Make sure direction correct) Color Inscribed plate Holder Inscribed display With Series illuminated pushbutton switches indicators (indicator lamps) with dia. mounting holes, internal inscribed plate engraved, information displayed inserting film. 19.8mm Main unit Main unit Cautions Series dia.) Mounting removing LEDs LEDs mounted removed from front panel, using lamp replacement tool (Part. ACDL1803). [Removing LED] Insert lamp replacement tool head LED, turn slightly left while pressing lightly remove bulb. Handling insulating terminal cover Align marks main unit insulating terminal cover, insert cover. Note) When connecting wiring, insert lead into hole insulating terminal cover before soldering Lamp replacement tool ACDL1803 [Mounting LED] Insert lamp replacement tool lightly into head LED, hold that position. Projection Lamp replacement tool Wiring When attaching insulating terminal cover switch block with solder/tab terminals, solder wire lamp terminal inner side terminal (the switch terminal side). Lamp terminal Inner side Switch terminal Insulating terminal cover Projection Align LED's projections with slits grooves inside main unit insert turning right while pressing lightly install Slit Grooves Slit Precautions when connecting wiring Terminals should soldered less than seconds, 260°C less than seconds, without applying external force. When doing this work, make sure soldering iron does come contact with switch itself, that tensile force applied terminal. Non-corroding liquid resin flux should used. Positive Lock connectors (made Co.) Easy Lock connectors (made Nichifu Co.) used terminals. table below shows recommended models connectors. Item Positive Lock connectors Co.) 175412-1 174778-1 1.25 174779-1 Easy Lock connectors Nichifu Co.) OSS0.3 62852F3 OSS1.25 62815F3 NET1-28-1P When using illumination LEDs configured semiconductors, they used voltage exceeding maximum operating voltage, element deteriorate because irregular heat generation, causing noticeable drop intensity, discoloration, failure light, other problems. External noise, transient voltage, transient current applied circuit cause same types problems. With illuminated types that have rated voltage VDC, AC/DC, AC/DC particular, following items should given careful consideration when using LED. Power supplies illumination with rated voltage AC/DC, AC/DC illumination used with rated voltage AC/DC, AC/DC both alternating direct current, either alternating current direct current power supplies used with these. voltage used should within range ±10% rated voltages both alternating direct current. Direct current power supplies Constant-voltage power supplies switching other power supplies These ideal power supplies. They should used within operating voltage range block. Batteries When charging, immediately after charging, please aware that voltage exceed operating voltage some cases. Make sure voltage within range ±10% rated voltage (±5% rated voltage Full-wave rectification Since both alternating direct current used, there need rectification using diode bridge. Please aware that, full-wave rectification using diode bridge used, rectifying diode cause voltage drop, resulting decreased intensity. Single-phase half-wave rectification This appropriate power supply block. recommend using direct current constant-voltage power supply. Noise External noise cause element deteriorate, causing noticeable drop intensity, discoloration, failure light, other problems. situations where this occur, preventive measures noted below should considered. element such element surge absorber should used prevent adverse effects caused noise. (Circuit example Alternating current cases with adapter, etc. with adapter, etc. Relay, coil, solenoid, etc. (Reference value) 0.1µF (Circuit example Direct current case (Reference values) Current capacitance diode: value equivalent higher than that operating current solenoid other components Reverse dielectric strength Diode diode: Approx. times operating voltage solenoid other components Relay, coil, solenoid, etc. Terminal Housing Cautions Series dia.) Corrective action dark illumination Leakage current Leakage current from non-contact switch that lights block from contact protective circuit cause block light faintly some cases even output off. this happens, following corrective steps should taken. block (direct-current type) being lighted transistor output type non-contact switch, insert dividing resistor parallel with block. (Circuit example) Handling Usage Precautions Aggregate tight mounting Please aware that heat caused aggregate tight mounting indicator lamps illuminated pushbutton switches continuously lamps cause ambient temperature exceed prescribed amount. Measures must taken ventilate lower operation voltage mounting panel metal product being used sealed control panel. Replacement buttons (illuminating non-illuminating) replace alternate type buttons (illuminating non-illuminating) when they locked. (Replacing while locked might damage internal mechanism.) must release locks before replacing. Storage place Please within working ambient temperature humidity ranges given ratings display. When using location where oil, water dirt present, install dust cover that foreign substances cannot enter sliding part pushbutton. Contact (microswitch) When using identical (normal close) (normal open) microswitch contacts, connect wrong voltage wrong type power supply. Doing will cause dead short. resistance product been evaluated with commonly used standard machining cooling oil. Please inquire about other oils, since some special oils possible. Leakage current when output Dividing resistor block (alternating-current type) being lighted TRIAC output type non-contact switch built into element, insert element parallel with block. (Circuit example) (Reference value) 0.1µF Leakage current with adapter, etc. block (alternating-current type) being lighted relay output which element that protects contact been connected parallel, insert element parallel with block. (Circuit example) (Reference value) 0.1µF with adapter, etc. Leakage current Induction When using units with adaptors, induction from surrounding line cause lamp light dimly. Corrective action: Insert element parallel with block. line (Reference value) 0.1µF with adapter, etc. Induced current Series Block Items dia.) (ACEL, ACSL, ACKL, ACCL, ACDL) Series Block Items dia.) Please "Ordering block items" information combining block items with dia. mounting holes. TYPES Color block illuminated pushbutton pushbutton (transparent buttons) Form Orange Yellow Green Blue White Black Part dia. projecting type ACEL112R ACEL112J ACEL112Y ACEL112G ACEL112L ACEL112X ACEL112B square flat type ACEL113R ACEL113J ACEL113Y ACEL113G ACEL113L ACEL113X ACEL113B flat type ACEL114R ACEL114J ACEL114Y ACEL114G ACEL114L ACEL114X ACEL114B Note: "White" non-colored transparent. indicator (indicator lamp) (transparent buttons) Form Orange Yellow Green Blue White dia. projecting type ACEL102R ACEL102J ACEL102Y ACEL102G ACEL102L ACEL102X square flat type ACEL103R ACEL103J ACEL103Y ACEL103G ACEL103L ACEL103X flat type ACEL104R ACEL104J ACEL104Y ACEL104G ACEL104L ACEL104X Part Note: "White" non-colored transparent. Mushroom button Form Orange Yellow Green Blue White Black dia. illuminated pushbutton ACEL120KR ACEL120KJ ACEL120KY ACEL120KG ACEL120KL ACEL120KX dia. pushbutton ACEL130KR ACEL130KY ACEL130KG ACEL130KL ACEL130KX ACEL130KB dia. illuminated pushbutton ACEL145KR ACEL145KJ ACEL145KY ACEL145KG ACEL145KL ACEL145KX dia. pushbutton ACEL155KR ACEL155KY ACEL155KG ACEL155KL ACEL155KX ACEL155KB Part Notes: button illuminated pushbutton transparent pushbutton non-transparent. Black color only pushbutton orange only illuminated pushbutton. inscribed plate (ACDH1836) included with dia. mushroom button illuminated pushbutton. Operation block illuminated pushbutton, non-illuminated pushbutton indicator (indicator lamp) Form Momentary Alternate Indicator (indicator lamp) Operation characteristics Part Part Part dia. projecting type ACEL1221 ACEL1222 ACEL1220 square flat type ACEL1231 ACEL1232 ACEL1230 flat type ACEL1241 ACEL1242 ACEL1240 dia. mushroom type ACEL2251 ACEL2252 Note: dia. projecting type dia. mushroom pushbutton. Series Block Items dia.) (ACEL, ACSL, ACKL, ACCL, ACDL) selector switches Form Operation methods Part dia. projecting type 2-notch 3-notch manual reset manual reset ACSL12521 ACSL12523 square flat type 2-notch 3-notch manual reset manual reset ACSL12321 ACSL12323 flat type 2-notch 3-notch manual reset manual reset ACSL12421 ACSL12423 selector switches Form Operation methods square flat type 2-notch manual reset 2-notch automatic reset 3-notch manual reset removal positions position ACKL1232111 position ACKL1232121 Both positions ACKL1232131 flat type 2-notch manual reset 2-notch automatic reset 3-notch manual reset position ACKL1232211 removed positions ACKL1232371 Part Form Operation methods removal positions position ACKL1242111 position ACKL1242121 Both positions ACKL1242131 dia. flat type 2-notch manual reset 2-notch automatic reset 3-notch manual reset position ACKL1242211 removed positions ACKL1242371 Part Form Operation methods removal positions position ACKL1252111 position ACKL1252121 Both positions ACKL1252131 position ACKL1252211 removed positions ACKL1252371 Part Switch block (tight mounting type) Form Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Single pole Double poles Single pole Double poles Part Part Part Part illuminated pushbutton switches ACCL16112 ACCL16212 ACCL16122 ACCL16222 non-illuminated pushbutton switches ACCL26112 ACCL26212 ACCL26122 ACCL26222 indicator (indicator lamp) Part ACCL16002 Note: Terminals board also possible. Lamp holder Part Unit ACDL1870 pcs. Note: *Please order lamp holders units pieces. Series Block Items dia.) (ACEL, ACSL, ACKL, ACCL) Series Block Items dia.) Please "Ordering block items" information combining block items with dia. mounting holes. TYPES Color block illuminated pushbutton pushbutton (transparent buttons) RoHS Directive compatibility information http://www.nais-e.com/ Form Orange Yellow Green Blue White Black 25.8 dia. projecting type ACEL116R ACEL116J ACEL116Y ACEL116G ACEL116L ACEL116X ACEL116B 25.8 dia. flat type ACEL117R ACEL117J ACEL117Y ACEL117G ACEL117L ACEL117X ACEL117B 25.8 square flat type ACEL118R ACEL118J ACEL118Y ACEL118G ACEL118L ACEL118X ACEL118B Part Note: "White" non-colored transparent. indicator (indicator lamp) (transparent buttons) Form Orange Yellow Green Blue White 25.8 dia. flat type ACEL107R ACEL107J ACEL107Y ACEL107G ACEL107L ACEL107X 25.8 square flat type ACEL108R ACEL108J ACEL108Y ACEL108G ACEL108L ACEL108X Part Note: "White" non-colored transparent. Mushroom button Form Orange Yellow Green Blue White Black dia. illuminated pushbutton ACEL169KR ACEL169KJ ACEL169KY ACEL169KG ACEL169KL ACEL169KX dia. pushbutton ACEL179KR ACEL179KY ACEL179KG ACEL179KL ACEL179KX ACEL179KB Part Notes: button illuminated pushbutton transparent pushbutton non-transparent. Black color only pushbutton orange only illuminated pushbutton. inscribed plate (ACDL1837) included with dia. mushroom button illuminated pushbutton. Operation block illuminated pushbutton, non-illuminated pushbutton indicator (indicator lamp) Form Momentary Operation characteristics Alternate Indicator (indicator lamp) Part Part Part 25.8 dia. ACEL1261 ACEL1262 ACEL1260 25.8 square flat type ACEL1281 ACEL1282 ACEL1280 dia. mushroom type ACEL3291 ACEL3292 Series Block Items dia.) (ACEL, ACSL, ACKL, ACCL) selector switches Form Operation methods Part 25.8 dia. flat type 2-notch manual reset 3-notch manual reset ACSL12621 ACSL12623 25.8 round square type 2-notch manual reset 3-notch manual reset ACSL12721 ACSL12723 selector switches Form Operation methods 25.8 dia. flat type 2-notch manual reset 3-notch manual reset 25.8 round square type 2-notch manual reset 3-notch manual reset removal positions position Part position Both positions removed positions position position Both positions removed positions ACKL1262111 ACKL1262121 ACKL1262131 ACKL1262371 ACKL1272111 ACKL1272121 ACKL1272131 ACKL1272371 Switch block Form Standard type (Silver contact) Low-level circuit type (Gold-clad contact) Single pole Double poles Single pole Double poles Part Part Part Part illuminated pushbutton switches ACCL1211 ACCL1221 ACCL1212 ACCL1222 non-illuminated pushbutton switches ACCL2211 ACCL2221 ACCL2212 ACCL2222 indicator (indicator lamp) Part ACCL1200 Note: Terminals board screw terminals also possible. Other recent searchesTLFGE50C - TLFGE50C TLFGE50C Datasheet SNA-176 - SNA-176 SNA-176 Datasheet SNA-100 - SNA-100 SNA-100 Datasheet SAA5290 - SAA5290 SAA5290 Datasheet PG05FSUL2 - PG05FSUL2 PG05FSUL2 Datasheet IW4021B - IW4021B IW4021B Datasheet F1772-4000 - F1772-4000 F1772-4000 Datasheet CDLE-057-039 - CDLE-057-039 CDLE-057-039 Datasheet
Privacy Policy | Disclaimer |