| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
(J4) TOGGLE SWITCHES CONSTRUCTION Wedge mechanism
Top Searches for this datasheetTOGGLE SWITCHES WITH HIGH INRUSH RESISTANCE (J4) TOGGLE SWITCHES CONSTRUCTION Wedge mechanism <Flat lever type> Handle with nice feel Oxide alloy contact Superior anti-corrosiveness Superior anti-weld dia. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Excellent anti-inrush properties allow handle large inrush currents. With wedge mechanism that increases contact efficiency times through oxide alloy superior anti-weld properties, this compact switch capable highcapacity switching. This makes ideal circuits with high inrush currents such those motor load lamp load. High level safety with least between contacts. Compliant with overseas safety standards. (ON-OFF ON-ON type) Insulation distance between recharge part ground least between poles least Compliant with Electrical Appliance Material Control (Class standard. Structure prevents flux from flowing sealant used around terminals completely prevents flux from flowing Fire retardant molding material used body. Excels anti-arcing (180 antitracking (600 through UL94V-0 fire retardant electric-use molding material. Wedge mechanism increases contact efficiency times temperature rises controlled high capacity switching made possible. UL94V-0 molded body material Superior antiarcing fire retardant properties Sealant completely prevents flux from flowing from around terminals. PRECAUTIONS WHEN USING CADMIUM-FREE CONTACT TYPE Models with cadmium-free contacts have been introduced order reduce environmentally harmful substances. ("F" affixed part number.) customers currently using products with cadmium-containing contacts part number) please make switch models with cadmium-free contacts. When switching, operating life differ depending load. Please sure verify this conducting evaluation using actual equipment. ORDERING INFORMATION type toggle switch Number poles shape terminal: 1-pole, Solder terminal 2-pole, Solder terminal 4-pole, Solder terminal 1-pole, .110 Quick-connect terminal 2-pole, .110 Quick-connect terminal 4-pole, .110 Quick-connect terminal Shape handle: Standard toggle Flat lever Kind operation: ON-OFF ON-ON ON-OFF-ON Shape nut: Hexagonal Cadmium-free product ON-OFF-<ON> <ON>-OFF-<ON> ON-OFF-<ON> Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. PRODUCT TYPES Standard toggle Number poles Kind operation Momentary position ON-OFF ON-ON ON-OFF-ON ON-<ON> <ON>-OFF-<ON> ON-OFF-<ON> ON-OFF ON-ON ON-OFF-ON ON-<ON> <ON>-OFF-<ON> ON-OFF-<ON> ON-OFF ON-ON ON-OFF-ON ON-<ON> <ON>-OFF-<ON> ON-OFF-<ON> 1-pole 2-pole 4-pole Solder terminal Part AJ41100F AJ41110F AJ41120F AJ41130F AJ41140F AJ41150F AJ42100F AJ42110F AJ42120F AJ42130F AJ42140F AJ42150F AJ44100F AJ44110F AJ44120F AJ44130F AJ44140F AJ44150F .110 Quick-connect terminal Part AJ45100F AJ45110F AJ45120F AJ45130F AJ45140F AJ45150F AJ46100F AJ46110F AJ46120F AJ46130F AJ46140F AJ46150F AJ48100F AJ48110F AJ48120F AJ48130F AJ48140F AJ48150F Remark: Standard installation accessories included with product. Flat lever Number poles Kind operation Momentary position ON-OFF ON-ON ON-OFF-ON ON-<ON> <ON>-OFF-<ON> ON-OFF-<ON> ON-OFF ON-ON ON-OFF-ON ON-<ON> <ON>-OFF-<ON> ON-OFF-<ON> ON-OFF ON-ON ON-OFF-ON ON-<ON> <ON>-OFF-<ON> ON-OFF-<ON> 1-pole 2-pole 4-pole Solder terminal Part AJ41300F AJ41310F AJ41320F AJ41330F AJ41340F AJ41350F AJ42300F AJ42310F AJ42320F AJ42330F AJ42340F AJ42350F AJ44300F AJ44310F AJ44320F AJ44330F AJ44340F AJ44350F .110 Quick-connect terminal Part AJ45300F AJ45310F AJ45320F AJ45330F AJ45340F AJ45350F AJ46300F AJ46310F AJ46320F AJ46330F AJ46340F AJ46350F AJ48300F AJ48310F AJ48320F AJ48330F AJ48340F AJ48350F Remark: Standard installation accessories included with product. Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Accessories Installation accessories (Repair parts) Standard installation accessories Product name Front (Nickel plated) Back (Uni-chrome plated) Keying washer 18.2 dia. 12.3 dia. Lock washer Optional installation accessories Front Knurl (Nickel plated) Dimensions (mm) (16.17) (16.17) 12.3 dia. 15.6 dia. dia. Part AJ3081 AJ3082 AJ3083 AJ3084 AJ3080 Remark: selling unit each accessory pieces. Accessories (Option) Product name Indication plate (aluminum)*3 ON-OFF ON-ON 12.3 dia. 12.3 dia. dia. Rubber cap*1, rubber type Silicone rubber type dia. Dimensions (mm) dia. 24.5 dia. 24.5 Part WD1901 WD1902 WD1911 WD1811* Remarks: asterisk part number WD1811* silicon rubber type rubber where letter representing color should inserted. (Standard models: black; red; grey. Made order: yellow; green.) Rubber rubber caps only available black. Letters display panel aluminum colored area surrounding letters black. Rubber caps compatible with switch, T-15 series switch, T-10 series switch, T-03/T-06 series switches (when plate thickness less). SPECIFICATIONS Contact rating type Kind load ON-OFF ON-ON 1-pole 2-pole 125V 250V 250V 300W 100V 4-pole 250V 250V 200W 100V Min. Min. Min. ON-OFF-ON ON-<ON> <ON>-OFF-<OFF> ON-OFF-<ON> 1-pole 2-pole 4-pole 125V 250V 250V 250V 300W 100V 200W 100V 200W 125V 400W 250V 100W 125V 200W 250V 250V 200W 100V 100W 100V 125V 100W 250V Electrical life Electrical life Resistive load Inductive load 0.6) Lamp load (incandescent) Motor load (single phase) Min. Min. Min. Min. Min. Min. 200W 125V 400W 250V 125V 100W 250V Min. Remark: rating displayed product only. Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Characteristics Mechanical life Electrical life Insulation distance Insulation resistance Breakdown voltage Contact resistance Vibration resistance Shock resistance Actuator strength (static load) Terminal strength (static load) Ambient temperature Contact material Min. cpm) above. cpm) Between grounds: Min. Between poles: Min. Between contacts: Min. (ON-OFF ON-ON type only) Min. measured insulation resistive meter) ON-OFF ON-ON type: 2000 Vrms, Other types: 1500 Vrms detection current: 10mA) Initial, Max. voltage drop double amplitude (contact opening Max. 10µs) Min. m/s2 (contact opening Max. 10µs) 112.7N min. 24.5N min. -25°C +85°C (Not freezing below 0°C) AgZnO alloy CIRCUIT DIAGRAM 1-pole 2-pole 4-pole Terminal arrangement seen from terminal side) Keyway Keyway Keyway Keyway ON-OFF type does have terminal 2-3, 2-3, 1-2, 2-3, 1-2, ON-OFF type does have terminal 1-3, 4-6, 7-9, 10-12 2-3, 5-6, 8-9, 11-12 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 1-2, 4-5, 7-8, 10-11 ON-OFF type does have terminal ON-OFF Keyway Handle position contact terminal number ON-ON ON-<ON> Keyway Keyway Keyway ON-OFF-<ON> <ON>-OFF-<ON> ON-OFF-<ON> Keyway Keyway Remark Remark: ON-<ON>, ON-OFF-<ON> type, lever springs back (momentary position) when pushed toward keyway side. MOUNTING DIMENSIONS 12.5 dia. 12.5 dia. 12.3 dia. Front 11.5 9.2±0.1 +0.2 dia. Keying washer Lock washer Back Panel cutout (mm) Panel thickness Max. Max. Max. (without keying washer) (without keying washer) Remark: panel installations, sure back nut. HANDLE SHAPE (mm) Standard toggle dia. Turn angle: Flat lever dia. Turn angle: 17.5 ±0.4 Keyway 10.9 ±0.4 ±0.4 Keyway 10.9±0.4 Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. DIMENSIONS (mm) body terminal shape (For standard toggle) (General tolerance: ±0.5) Solder terminal 1-pole type 1-pole Turn angle: 24°±4° dia. 2-pole 4-pole 17.5 ±0.4 Keyway 10.9 ±0.4 4-pole type 17.6 7.62 7.62 25.4 7.62 19.5 7.62 7.62 7.62 Remarks: 1-pole, ON-OFF type does have terminal 2-pole, ON-OFF type does have terminal 4-pole, ON-OFF type does have terminal .110 Quick-connect terminal 1-pole Turn angle: 24°±4° dia. 2-pole 4-pole 17.5 ±0.4 Keyway 10.9 ±0.4 17.6 5.5±0.1 ±0.025 7.62 7.62 25.4 3-1.2 ±0.05 dia. Hole ±0.1 -0.15 7.62 19.5 7.62 7.62 7.62 7.1±0.15 Remarks: 1-pole, ON-OFF type does have terminal 2-pole, ON-OFF type does have terminal 4-pole, ON-OFF type does have terminal Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. NOTES Installation Keep panel tightening torque less than 1.96 Also, tighten nut, holding switch. induction load switching (relays, solenoids buzzers, etc.) recommend inserting suitable spark quenching circuit order prevent damage contacts possibility arcing caused back voltage. hand soldering, 350°C soldering iron should used with soldering completed within seconds. Also, care should taken touch body switch with soldering iron. cannot guarantee performance product dropped onto hard, concrete floor from height more. Please careful. When using switch, careful apply unreasonable perpendicular force (static loading 112.7 more) operation direction. Verification insulation distance Please verify that insulation distances have been maintained between terminals with ground after installation wiring switch. When wiring .110 Quick connect terminal recommend using receptacle with insulating sleeve. Also, after wiring make sure that terminals free from steady forces. This product hermetically sealed, performance could deteriorate under certain ambient conditions. Avoid using storing these switches location where they will exposed corrosive gases, silicon, high dust levels, which have adverse effect contacts. switches where they will come into contact with water through splashing, etc. This could cause abnormal heating smoke generation, which could damage circuit lead accident. atmospheres that contain combustible gas. Such could cause fires explosions. Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. Other recent searchesSTN3446 - STN3446 STN3446 Datasheet SC5388 - SC5388 SC5388 Datasheet PI49FCT32805 - PI49FCT32805 PI49FCT32805 Datasheet MPS-213011-85 - MPS-213011-85 MPS-213011-85 Datasheet CFPS-72 - CFPS-72 CFPS-72 Datasheet AP2402 - AP2402 AP2402 Datasheet A31W65132 - A31W65132 A31W65132 Datasheet 2SC5938A - 2SC5938A 2SC5938A Datasheet
Privacy Policy | Disclaimer |