| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
VOLT INPUT WATT -55°C +125°C operation input Fully isolated Magne
Top Searches for this datasheetMCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT -55°C +125°C operation input Fully isolated Magnetic feedback Fixed frequency typ. Topology Current Mode Flyback transient protection single dual models) Inhibit function Indefinite short circuit protection Undervoltage lockout efficiency (MGH models) MODELS OUTPUT SINGLES (MCH) DUALS SERIESSINGLE DUAL DC/DC CONVERTERS With miniature footprint just square inches, Seriesof DC/DC converters delivers watts output power while saving significant board real estate. wide input voltage range accepts varying voltages military, aerospace, space power tightly regulates output voltages protect downstream components. Transient protection volts milliseconds exceeds requirements MIL-STD-704A 5.2, volt single models volt dual model. volt single dual converters will withstand transients volts milliseconds. INHIBIT FUNCTION When open collector logic applied inhibit terminal, converter shuts down lowers output voltage near zero input current Leaving terminal open applying open collector logic high will enable converter. PROTECTION Undervoltage lockout prevents Series converters from operating below approximately input voltage keep system current levels smooth, especially during initialization re-start operations. models include soft-start function prevent large current draw minimize overshoot. converters also provide short circuit protection restricting current. CONVERTER DESIGN Series DC/DC converters incorporate continuous flyback topology with constant switching frequency approximately kHz. Current-mode pulse width modulation (PWM) provides output voltage regulation. Output error voltage magnetically back input side regulate output voltage. Regulation also affected load; refer Electrical Characteristics tables following pages. Dual models regulate negative output with magnetic coupling positive output. total load output providing that other output carries minimum total load. dual models used double output voltage connecting load between positive negative outputs, leaving common unconnected. (ex: MCH2805D used output.) MIL-STD-461 Interpoint's FMSA-461 filter pass CE03 requirements MIL-STD-461C. CONVENIENT PACKAGING Series converters packaged hermetically sealed, projection-welded metal cases which provide EMI/RFI shielding. Crane Aerospace Electronics Electronics Group (Interpoint Brand) 97005 Redmond 98073-9705 425.882.3100 electronics@craneae.com www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT SERIESSINGLE DUAL DC/DC CONVERTERS Seriesof DC/DC converters delivers watts output power labor saving surface mount package. wide input voltage range accepts varying voltages military, aerospace, space applications. Single output converters feature outputs volts while dual output models feature outputs ±12, volts. Transient protection volts milliseconds exceeds requirements MIL-STD-704A volt single dual models. volt single dual converters will withstand transients volts milliseconds. PROTECTION Undervoltage lockout prevents Series converters from operating below approximately input voltage keep system current levels smooth, especially during initialization re-start operations. models include soft-start function prevent large current draw minimize overshoot. Series converters also provide short circuit protection limiting current approximately 125% full load. MIL-STD-461 Interpoint's FMGA-461 filter pass CE03 requirements MIL-STD-461C. CONVERTER DESIGN Series DC/DC converters incorporate continuous flyback topology with constant switching frequency approximately kHz. Output voltage regulation accomplished primary side using current-mode pulse width modulation (PWM). Regulation affected output load; refer specifications tables more information. dual output models, total load output providing other output carries minimum total load. dual models used double output voltage connecting load between positive negative outputs, leaving common unconnected. example MGH2805D volt dual output) used output. SURFACE MOUNT PACKAGE DC/DC converters surface mounted with pick-andplace equipment manually. recommended that case attached with flexible epoxy adhesive silicone which thermally conductive watt /meter/°K). Internal components soldered with SN96 (melting temperature 221°C) prevent damage during reflow. Maximum reflow temperature surface mounting converter 220°C maximum seconds. SN60, recommended types solder. Hand soldering should exceed 300°C seconds pin. hermetically sealed metal cases available different lead configurations. case dimensions options. INHIBIT FUNCTION When open collector logic applied inhibit terminal, converter shuts down lowers output voltage near zero input current Leaving terminal open applying open collector logic high will enable converter. Positive Input +Vin Inhibit Shutdown Controller +Vout Input Common Case Ground Output Common Negative Output Positive Output Dual models only FIGURE BLOCK DIAGRAM www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT OPERATING CONDITIONS CHARACTERISTICS Input Voltage Range continuous msec transient single dual models) Output Power Capacitive Load single output models each output, dual output models Lead Soldering Temperature Reflow 220°C sec. SN60, recommended solder Hand solder 300°C sec. lead Storage Temperature Range (Case) -65°C +150°C Case Operating Temperature (Tc) -55°C +125°C full power -55°C +135°C absolute Derating Output Power/Current (Tc) Linearly from 100% 125°C 135°C Output Voltage Temperature Coefficient ppm/°C typical Input Output Capacitance typical Current Limit 125% full load typical Isolation megohm minimum Audio Rejection typical Conversion Frequency (kHz) 25°C min, typ, -55°C +125°C min, typ, Inhibit Voltage (unit enabled) Undervoltage Lockout input typical INHIBIT Inhibit Open Collector Logic (output disabled) Logic voltage Inhibit current Referenced input common Logic high (output enabled) open collector MECHANICAL ENVIRONMENTAL Size (maximum) models 0.980 0.805 0.270 inches (24.89 20.45 6.86 case dimensions. models 1.010 0.880 0.250 inches (25.65 22.35 6.35 Shown page with "gull wing" lead option, also available with straight leads. case dimensions options. Weight (maximum) grams typical Screening Standard, (Class QML). "883, Class Products Element Evaluation" "883, Class Products Environmental Screening" more information. POSITIVE INPUT 0.47 typical +VIN POSITIVE OUTPUT INHIBIT SHUTDOWN CONTROLLER +VOUT OUTPUT COMMON NEGATIVE OUTPUT DUAL MODELS ONLY INPUT COMMON FIGURE BLOCK DIAGRAM www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT MODELS Single Output Positive Input Input Common Positive Output Output Common Case Ground connection Inhibit Dual Output Positive Input Input Common Positive Output Output Common Case Ground Negative Output Inhibit Squared corner cover indicate one. case dimensions. FIGURE PINS Inhibit (INH1, INH2) (pins with connection) Leave unconnected Ground input common MODELS Single Output Positive Input connection Input Common Positive Output Case Ground Output Common Case Ground connection connection connection Inhibit Dual Output Positive Input connection Input Common Positive Output Case Ground Output Common Case Ground connection Negative Output connection Inhibit VIEW Differently colored glass bead around dimple header (bottom side case) indicates one. Cover marking oriented with upper right corner. case dimensions "gull-wing" option. FIGURE meet specified performance, pins must connected except Connection" pins. www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Model Selection Table (see next page options) MODEL NUMBERING NUMBERS STANDARD MICROCIRCUIT DRAWING (SMD) 5962-9569601HXC 5962-9569701HXC 5962-9569801HXC 5962-9570201HXC 5962-9570301HXC 5962-9570401HXC SERIES SIMILAR PART MCH2805S/883 MCH2812S/883 MCH2815S/883 MCH2805D/883 MCH2812D/883 MCH2815D/883 Base Model Input Voltage Output Voltage decimal point, Vout) Number Outputs single, dual) Screening (Standard screening designator this position.) exact specifications product, refer drawing. SMDs downloaded from: Model Selection MCH28 Base model Vout value number outputs case option screening Choose from each following rows Vout value Number outputs Case option Screening singles: 5R2, duals: decimal point, (single) (dual) standard (case leave blank) standard screening, leave blank screening), /883 (Class QML) www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Model Selection Table (see previous page options) MODEL NUMBERING NUMBERS Base Model Input Voltage Output Voltage Number Outputs single, dual) STANDARD MICROCIRCUIT DRAWING (SMD) 5962-9569601HYC 5962-9569701HYC 5962-9569801HYC 5962-9570201HYC 5962-9570301HYC 5962-9570401HYC MCH/MGH SERIES SIMILAR PART MGH2805S/883 MGH2812S/883 MGH2815S/883 MGH2805D/883 MGH2812D/883 MGH2815D/883 Gull Wing Lead Option (Straight leaded case designator this position.) Screening (Standard screening designator this position.) exact specifications product, refer drawing. gull wing lead option, replace number (HYC) with (HZC). SMDs downloaded from Model Selection MGH28 Base model Vout value number outputs screening Choose from each following rows Vout value Number outputs Screening singles: decimal point, duals: (single) (dual) standard screening, leave blank screening), /883 (Class QML) www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. SINGLE OUTPUT MODELS PARAMETER CONDITIONS OUTPUT VOLTAGE2 25°C -55°C +125°C OUTPUT CURRENT MCH2805S MCH2812S MCH2815S 4.95 5.05 11.88 12.12 14.85 15.15 4.80 5.20 11.52 12.48 14.40 15.60 -500 -500 -500 -500 0.75 0.75 -700 -800 -700 -800 1600 1600 UNITS OUTPUT POWER OUTPUT RIPPLE VOLTAGE LINE REGULATION LOAD REGULATION INPUT VOLTAGE LOAD FULL INPUT CURRENT INPUT RIPPLE CURRENT3 EFFICIENCY LOAD FAULT STEP LOAD RESPONSE6 STEP LINE RESPONSE6 START-UP -55°C +125°C -55°C +125°C FULL LOAD -55°C +125°C FULL1 -55°C +125°C CONTINUOUS TRANSIENT1 LOAD -55°C +125°C INHIBITED -55°C +125°C -55°C +125°C 25°C -55°C +125°C POWER DISSIPATION -55°C +125°C RECOVERY1 --55°C +125°C %-100%- LOAD TRANSIENT -55°C +125°C RECOVERY =-55°C +125°C TRANSIENT1 -55°C +125°C RECOVERY1 -55°C +125°C DELAY -55°C +125°C OVERSHOOT1 -55°C +125°C 1400 1400 -1000 1000 -850 -1000 1000 -850 0.47 CAPACITIVE LOAD Notes: Guaranteed design, tested. Specified total Maximum duration short circuit: 25°C-- seconds, 125°C seconds. Load fault short circuit (<50 mohms). Recovery into resistive full load. Transition Recovery time settle within Vout final value. Max. spec indicates converter's total power, available from either output. www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. SINGLE OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT OUTPUT POWER OUTPUT RIPPLE VOLTAGE LINE REGULATION LOAD REGULATION CONDITIONS 25°C -55°C +125°C MGH2805S 4.95 4.80 -400 -500 -400 -500 0.75 0.75 5.05 5.20 11.88 11.52 -700 -800 -900 -1000 MGH2812S 12.12 12.48 1300 1400 1000 14.85 14.40 -700 -800 -750 -850 MGH2815S 0.47 15.15 15.60 1500 1600 UNITS -55°C +125°C -55°C +125°C FULL LOAD -55°C +125°C FULL LOAD -55°C +125°C INPUT VOLTAGE LOAD FULL INPUT CURRENT CONTINUOUS TRANSIENT LOAD -55°C +125°C FULL LOAD -55°C +125°C INHIBITED -55°C +125°C INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT -55°C +125°C 25°C -55°C +125°C POWER DISSIPATION -55°C +125°C RECOVERY --55°C +125°C TRANSIENT -55°C +125°C RECOVERY -55°C +125°C TRANSIENT -55°C +125°C RECOVERY -55°C +125°C DELAY -55°C +125°C OVERSHOOT -55°C 25°C STEP LOAD RESPONSE5 %-100%- STEP LINE RESPONSE5 START-UP Notes Specified full load. Max. duration short circuit: 25°C- seconds; 125°C seconds. Load fault short circuit (<50 mohms). Recovery into resistive full load. Input step transition s.Recovery time settle within Vout final value. www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. DUAL OUTPUT MODELS PARAMETER CONDITIONS 25°C OUTPUT VOLTAGE -55°C +125°C OUTPUT CURRENT7 MCH2805D ±4.95 ±5.05 ±4.80 ±5.20 ±150 -300 -400 -250 -300 MCH2812D MCH2815D ±11.88 ±12.12 ±14.85 ±15.15 ±11.52 ±12.48 ±14.40 ±15.60 ±62.5 -600 -700 -500 -600 1100 1200 -600 -700 -500 -600 1300 1400 UNITS OUTPUT POWER OUTPUT RIPPLE VOLTAGE -55°C +125°C -55°C +125°C -55°C +125°C FULL -55°C +125°C FULL1 -55°C +125°C CONTINUOUS TRANSIENT1 LOAD -55°C +125°C INHIBITED -55°C +125°C -55°C +125°C 25°C -55°C +125°C LINE REGULATION LOAD REGULATION ±VOUT INPUT VOLTAGE LOAD FULL INPUT CURRENT INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT POWER DISSIPATION -55°C +125°C RECOVERY -55°C +125°C STEP LOAD %-100%- LOAD TRANSIENT RESPONSE VOUT -55°C +125°C RECOVERY -55°C +125°C STEP LINE RESPONSE6 VOUT TRANSIENT1 -55°C +125°C RECOVERY -55°C +125°C START-UP DELAY VDC, VOUT -55°C +125°C OVERSHOOT1 -55°C +125°C CAPACITIVE LOAD Notes: Guaranteed design, tested. Specified balanced load. Maximum duration short circuit: 25°C-- seconds, 125°C seconds. Load fault short circuit (<50 mohms). Recovery into resistive full load, with output shorted time. Transition Recovery time settle within Vout final value. Max. spec indicates converter's total power, available from either output. Specification applies both Vout. Although minimum load required, load output voltage increase 15%. www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. DUAL OUTPUT MODELS PARAMETER OUTPUT VOLTAGE1 OUTPUT CURRENT OUTPUT POWER OUTPUT RIPPLE VOLTAGE +VOUT -VOUT LINE REGULATION LOAD REGULATION MGH2805D ±4.95 ±4.80 -300 -400 -250 -300 ±150 ±5.05 ±5.20 ±11.88 ±11.52 -600 -700 -500 -600 MGH2812D ±62.5 ±12.12 ±12.48 1100 1200 MGH2815D ±14.85 ±14.40 -600 -700 -500 -600 ±15.15 ±15.60 1300 1400 UNITS CONDITIONS 25°C -55°C +125°C -55°C +125°C -55°C +125°C -55°C +125°C FULL LOAD -55°C +125°C FULL LOAD -55°C +125°C CROSS REGULATION5 INPUT VOLTAGE LOAD FULL INPUT CURRENT -VOUT CONTINUOUS TRANSIENT LOAD -55°C +125°C FULL LOAD -55°C +125°C INHIBITED -55°C +125°C INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT -55°C +125°C 25°C -55°C +125°C POWER DISSIPATION -55°C +125°C RECOVERY -55°C +125°C STEP LOAD RESPONSE Vout %-100%- STEP LINE RESPONSE19 Vout START-UP VDC, Vout TRANSIENT -55°C +125°C RECOVERY -55°C +125°C TRANSIENT -55°C +125°C RECOVERY -55°C +125°C DELAY -55°C +125°C OVERSHOOT -55°C +125°C Notes: Specified load. Max. spec indicates converter's total available power. This available from either output. Specification applies both -Vout. Although minimum load required, load output voltage increase 15%. Cross regulation specified effect -Vout following percent ages total output power: +Po=80% -Po=20% Max. duration short circuit: 25°C seconds; 125°C seconds. Load fault short circuit (<50 mohms). Recovery into resistive full load. Input step transition s.Recovery time settle within Vout final value. www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Typical Performance Curves: 25°C Vin, 100% load, unless otherwise specified. SINGLE DUAL OUTPUT MODELS VOLT EFFICIENCY VOLT EFFICIENCY VOLT EFFICIENCY VOLT VOLT VOLT VOLT VOLT VOLT 0.25 OUTPUT POWER 0.75 1.25 1.75 VOLT MODELS 0.25 OUTPUT POWER 1.25 1.75 0.75 VOLT SINGLE MODELS 0.25 OUTPUT POWER 1.25 1.75 0.75 VOLT DUAL MODELS EFFICIENCY LOAD EFFICIENCY LOAD EFFICIENCY LOAD FIGURE div. FIGURE FIGURE ATTENUATION (dB) div. FULL LOAD HALF LOAD div. VOUT HALF LOAD FULL LOAD FREQUENCY (kHz) MCH2815S Representative models 200s div. MCH2805S 500s div. MCH2805S LINE TRANSIENT RESPONSE LOAD TRANSIENT RESPONSE AUDIO REJECTION FIGURE FIGURE FIGURE 20V/div. div. div. +VOUT FULL LOAD HALF LOAD -VOUT HALF LOAD FULL LOAD div. 2V/div. +VOUT -VOUT 200s div. MCH2815D VOUT -VOUT FULL LOAD HALF LOAD +VOUT HALF LOAD FULL LOAD 500s div. MCH2815D TIME (ms) MCH2805S Representative volt models LINE TRANSIENT RESPONSE LOAD TRANSIENT RESPONSE TURN-ON INTO FULL LOAD FIGURE www.craneae.com FIGURE Page 20060508 FIGURE MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Typical Performance Curves: 25°C Vin, 100% load, unless otherwise specified. SINGLE DUAL OUTPUT MODELS (CONT.) ±VOUT VOLTAGE CHANGE ±VOUT VOLTAGE CHANGE 20V/div. -VOUT 5V/div. -VOUT +VOUT +VOUT TIME (ms) MCH2815D Also representative MCH2812S MCH2815S OUTPUT LOAD DUAL ISOLATED LOAD LOAD LOAD LOAD TURN-ON INTO FULL LOAD 90/10 70/30 50/50 30/70 10/90 OUTPUT LOAD DUAL ISOLATED LOAD LOAD CROSS REGULATION CROSS REGULATION FIGURE FIGURE FIGURE MAXIMUM POWER SINGLE DUAL SINGLE DUAL DUAL SINGLE TRIP POINT 125% NARROWBAND EMISSION LEVEL Vout NOMINAL SAFE OPERATING AREA INPUT VOLTAGE MODELS FULL LOAD .015 FREQUENCY (MHz) LINE DROPOUT OUTPUT VOLTAGE OUTPUT LOAD FILTERED WITH FMSA FIGURE FIGURE FIGURE www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Typical Performance Curves: 25°C Vin, 100% load, unless otherwise specified. SINGLE DUAL OUTPUT MODELS VOLT EFFICIENCY EFFICIENCY VOLT 0.25 0.75 1.25 1.75 VOLT MODELS OUTPUT POWER VOLT VOLT VOLT 0.25 0.75 OUTPUT POWER EFFICIENCY VOLT 0.25 0.75 1.25 1.75 DUAL MODELS OUTPUT POWER VOLT VOLT VOLT 1.25 1.75 SINGLES EFFICIENCY LINE LOAD EFFICIENCY LINE LOAD EFFICIENCY LINE LOAD FIGURE FIGURE FIGURE div. ATTENUATION (dB) FULL LOAD HALF LOAD div. div. Vout HALF LOAD FULL LOAD FREQUENCY (kHz) MGH2815S Representative models div. MGH2805S div. MGH2805S LINE TRANSIENT RESPONSE LOAD TRANSIENT RESPONSE AUDIO REJECTION FIGURE FIGURE FIGURE 20V/div. div. div. +VOUT FULL LOAD HALF LOAD -VOUT HALF LOAD FULL LOAD div. 2V/div. +Vout -Vout div. MGH2815D Vout TIME (ms) MGH2805S Representative volt models -VOUT FULL LOAD HALF LOAD +VOUT HALF LOAD FULL LOAD div. MGH2815D TURN-ON INTO FULL LOAD LINE TRANSIENT RESPONSE LOAD TRANSIENT RESPONSE FIGURE FIGURE FIGURE www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT Typical Performance Curves: 25°C Vin, 100% load, unless otherwise specified. SINGLE DUAL OUTPUT MODELS (CONT.) ±Vout VOLTAGE CHANGE ±Vout VOLTAGE CHANGE 20V/div. -Vout 5V/div. -Vout +Vout +Vout TIME (ms) MGH2815D Also representative MGH2812S MGH2815S 90/10 70/30 50/50 30/70 10/90 TURN-ON INTO FULL LOAD OUTPUT LOAD DUAL LOAD LOAD OUTPUT LOAD DUAL LOAD LOAD LOAD LOAD CROSS REGULATION CROSS REGULATION FIGURE FIGURE FIGURE Vout NOMINAL SAFE OPERATING AREA TRIP POINT 125% FULL LOAD OUTPUT VOLTAGE OUTPUT LOAD FIGURE www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converter Cases VOLT INPUT WATT BOTTOM VIEW CASE Seam Seal Projection Weld 0.805 max. (20.45) 0.697 (17.70) Squared corner case indicate one. 0.018 0.002 dia. (0.46 0.05) 0.097 (2.46) 0.000 0.27 ±0.02 (6.9 ±0.5) 0.270 (6.98) 0.000 0.000 0.270 (6.86) 0.000 0.27 ±0.02 (6.9 ±0.5) 0.135 (3.43) 0.235 (5.97) 0.435?(11.05) 0.535 (13.59) 0.835 (21.21) Seal hole: 0.056 ±0.002 (1.42 ±0.05) Case dimensions inches (mm) Tolerance ±0.005 (0.13) three decimal places ±0.01 (0.3) decimal places unless otherwise specified CAUTION Heat from reflow wave soldering damage device. Solder pins individually with heat application exceeding 300°C seconds Materials Header Kovar/Nickel/Gold Cover Kovar/Nickel Pins Kovar/Nickel/Gold matched glass seal Case 20060110 Please refer numerical dimensions accuracy. information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. Copyright 1999-2006 Interpoint Corp. rights reserved. FIGURE CASE www.craneae.com Page 20060508 0.980 max. (24.89) MCH/MGH Single Dual DC/DC Converter Cases VOLT INPUT WATT VIEW CASE Differently colored glass bead around dimple header (bottom side case) indicates one. Cover marking oriented with upper right corner. 0.900 (22.86) 0.800 (20.32) 0.700 (17.78) 0.600 (15.24) 0.500 (12.70) 0.400 (10.16) 0.300 7.62) 0.200 5.08) 0.100 2.54) 0.000 0.000 0.010 (0.25) 0.50 (12.7) 1.870 ref. (47.50) 0.08 (2.0) 0.250 max. (6.35) 0.880 (22.35) (This view shows straight leads.) 1.010 (25.65) 0.015 (0.38) Straight Leads Seam seal 1.140 ref. (28.96) 0.135 ref. (3.43) 0.010 (0.25) Seal hole: 0.040 ±0.002 (1.02 ±0.05) Gull wing leads solder dipped. Lead dimensions prior solder dip. 0.010 (0.25) Bottom case bottom lead Gull Wing Leads Option Case dimensions inches (mm) Tolerance ±0.005 (0.13) three decimal places ±0.01 (0.3) decimal places unless otherwise specified 0.055 (1.40) CAUTION Maximum reflow temperature 220°C maximum seconds. SN60, SN62, SN63 recommended types solder. case Solder Pads Solder Mask instructions. Hand soldering should exceed 300°C seconds pin. Materials Header Kovar/Nickel/Gold Cover Kovar/Nickel Pins Kovar/Nickel/Gold matched glass seal Case November 2005 Please refer numerical dimensions accuracy. information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. Copyright 1999-2006 Interpoint Corp. rights reserved. 0.070 (1.78) 0.08 (2.0) FIGURE CASE www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT 883, CLASS PRODUCTS ELEMENT EVALUATION ELEMENT EVALUATION TEST PERFORMED (COMPONENT LEVEL) Element Electrical (probe) Element Visual Internal Visual Final Electrical Wire Bond Evaluation STANDARD (NON-QML) CLASS SLAMTM/C-SAM: Input Capacitors only (Add'l test, req. Definitions: Element Evaluation: Component testing/screening MIL-STD-883 determined MIL-PRF-38534 SLAMTM: Scanning Laser Acoustic Microscopy C-SAM: Mode Scanning Acoustic Microscopy Notes: Non-QML products meet requirements MIL-PRF-38534 Active components (Microcircuit Semiconductor Die) Passive components applicable filters that have wire bonds www.craneae.com Page 20060508 MCH/MGH Single Dual DC/DC Converters VOLT INPUT WATT 883, CLASS PRODUCTS ENVIRONMENTAL SCREENING TEST 125°C STANDARD non-QML 125°C non-QML Class /883 Pre-cap Inspection Method 2017, 2032 Temperature Cycle times) Method 1010, Cond. -65°C 150°C, ambient Method 1010, Cond. -55°C 125°C, ambient Constant Acceleration Method 2001, 3000 Method 2001, 500g Burn-In Method 1015, hours 125°C case, typical hours 125°C case, typical Final Electrical Test MIL-PRF-38534, Group Subgroups through -55°C, +25°C, +125°C case Subgroups +25°C case Hermeticity Test Fine Leak, Method 1014, Cond. Gross Leak, Method 1014, Cond. Gross Leak, 10-3) Final Visual Inspection Method 2009 Test methods referenced MIL-STD-883 determined MIL-PRF-38534. MCH/MGH Single Dual. 20060508. This revision supercedes previous releases. technical information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. MCH/MGH Series trademark Interpoint. Copyright 1994 2006 Interpoint Corporation. rights reserved. www.craneae.com Page Other recent searchesTRW54601 - TRW54601 TRW54601 Datasheet TLP117 - TLP117 TLP117 Datasheet SN74AUC16501 - SN74AUC16501 SN74AUC16501 Datasheet RN47A1JE - RN47A1JE RN47A1JE Datasheet IN4148 - IN4148 IN4148 Datasheet SX1070 - SX1070 SX1070 Datasheet DUG06C4-A - DUG06C4-A DUG06C4-A Datasheet 74LVT16244 - 74LVT16244 74LVT16244 Datasheet 74LVTH16244 - 74LVTH16244 74LVTH16244 Datasheet
Privacy Policy | Disclaimer |