| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Current Limiting Current limiting rated fuses equipped with mecha
Top Searches for this datasheetMedium Voltage Fuse2400 25,500 Current Limiting Current limiting rated fuses equipped with mechanical indicator striker that protrudes through fuse upon operation fuse. This provides visual identification blown fuse used trigger external devices. GENERAL INFORMATION terms "Medium Voltage" "high voltage" have been used interchangeably many people describe fuses operating above volts. Technically speaking, "medium voltage" fuses those intended voltage range from 2,400 38,000 VAC. "High voltage fuses circuits carrying voltages greater than 38,000 VAC. Rated fuses considered general purpose fuses used protect against high values fault current. rated fuses designed back-up protection. They must used series with other devices, such motor overload relays, order achieve both overload short circuit protection. Medium voltage fuses intended provide overload protection same sense fuses rated volts less. Medium voltage fuse current ratings have same meanings ampere ratings voltage fuses. medium voltage fuses limited their ability interrupt value overcurrents, especially those between 100% 200% fuse's continuous current rating. They designed carry their rated current without exceeding temperature rise permitted NEMA ANSI standards. Additional application data found Fuse Application section POWR-GARD Products catalog (PF101). Littelfuse offers complete selection rated medium voltage fuses protection transformers, potential transformers, feeders, motor circuits. Single, double, triple barrel designs available cover wide range current, voltage, interrupting ratings. Conventional ferrule type, clip lock, bolt-in mounting configurations available virtually application. Hermetically sealed fuses hazardous environments also offered. Contact factory your local Littelfuse representative additional fuse ratings custom mounting configurations. Hour Emergency Service available. Call 1-800-227-0029. APPLICATIONS Power Transformer Protection Potential Transformer Protection Motor Controller Back-up Protection Fused Switches Feeder Circuit Bolt-in Mount Fuse Rated Medium Voltage FuseCurrent Limiting Rated fuses have time current characteristics designed provide current limiting protection power transformers, potential transformers, power centers, feeder centers, unit stations. When properly applied, they protect against high value fault currents. NEMA Standards rated medium voltage fuses require that fuses rated 100E less open within seconds minutes) when subjected value 200-240% fuse's continuous current rating; fuses with rating larger than 100E must open within seconds minutes) when subjected current 220-240% fuse's continuous current rating. These values establish point time-current curve. Application Note: Since these fuses used protection general purpose circuits which contain transformers, motors, other equipment producing inrush and/or overload currents, fuses should generally rated 140% normal full load current, circuits should analyzed ensure that system load currents will exceed current rating fuse. CHARACTERISTICS Voltage Rating: 2,400 volts 38,000 volts Current Range: 600E OPTIONS Hermetically Sealed hazardous locations (add suffix part number) Clip-lock (CL) bolt-in styles available. 3"DIA 6.38" 9.75" Dim.A (Clip Center) Dim.B FIGURE FIGURE FIGURE RATED Catalog Number 10E-1C-2.75 15E-1C-2.75 20E-1C-2.75 25E-1C-2.75 30E-1C-2.75 40E-1C-2.75 50E-1C-2.75 65E-1C-2.75 80E-1C-2.75 100E-1C-2.75 125E-1C-2.75 150E-1C-2.75 200E-1C-2.75 125E-2C-2.75 150E-2C-2.75 175E-2C-2.75 200E-2C-2.75 225E-2C-2.75 250E-2C-2.75 300E-2C-2.75 350E-2C-2.75 400E-2C-2.75 450E-2C-2.75 Catalog Number 100E 125E 150E 175E 200E 250E 300E 400E Size 100E 125E 150E 200E 125E 150E 175E 200E 225E 250E 300E 350E 400E 450E Dim. (inches) Dim. (inches) Interrupting Rating (Asym) 10.875" 80,000 10.875" 80,000 Figure Number 2.75 Max. Rated Medium Voltage FuseCurrent Limiting RATED Catalog Number 10E-1C-5.5 15E-1C-5.5 20E-1C-5.5 25E-1C-5.5 30E-1C-5.5 40E-1C-5.5 50E-1C-5.5 65E-1C-5.5 80E-1C-5.5 100E-1C-5.5 125E-1C-5.5 150E-1C-5.5 175E-1C-5.5 200E-1C-5.5 125E-2C-5.5 150E-2C-5.5 175E-2C-5.5 200E-2C-5.5 250E-2C-5.5 300E-2C-5.5 350E-2C-5.5 400E-2C-5.5 450E-2C-5.5 500E-3C-5.5 550E-3C-5.5 600E-3C-5.5 5NLE-10E 5NLE-15E 5NLE-20E 5NLE-25E 5NLE-30E 5NLE-40E 5NLE-50E 5NLE-65E 5NLE-80E 5NLE-100E 5NLE-125E 5NLE-150E 5NLE-175E 5NLE-200E 5NLE2-225E 5NLE2-250E 5NLE2-300E 5NLE2-350E 5NLE2-400E 5NLE2-450E Catalog Number 100E 125E 150E 175E 200E 250E 300E 350E 400E 450E Size 100E 125E 150E 175E 200E 125E 150E 175E 200E 250E 300E 350E 400E 450E 500E 550E 660E 100E 125E 150E 175E 200E 225E 250E 300E 350E 400E 450E Dim. (inches) Dim. (inches) Interrupting Rating (Asym) 15.875" 80,000 15.875" 80,000 15.875" 80,000 Diagram Max. Max. 100E 125E 150E 175E 200E 250E 300E 350E 400E 450E 17-7/8" 80,000 17-7/8" 80,000 Rated Medium Voltage FuseCurrent Limiting RATED Catalog Number 10E-1C-8.25 15E-1C-8.25 20E-1C-8.25 25E-1C-8.25 30E-1C-8.25 40E-1C-8.25 50E-1C-8.25 65E-1C-8.25 80E-1C-8.25 100E-1C-8.25 125E-1C-8.25 150E-1C-8.25 125E-2C-8.25 150E-2C-8.25 200E-2C-8.25 250E-2C-8.25 300E-2C-8.25 350E-3C-8.25 400E-3C-8.25 8NLE-10E 8NLE-15E 8NLE-20E 8NLE-25E 8NLE-30E 8NLE-40E 8NLE-50E 8NLE-65E 8NLE-80E 8NLE-100E 8NLE2-100E 8NLE2-125E 8NLE2-150E 8NLE2-200E 8NLE2-250E Catalog Number 100E 125E 150E 125E 150E 200E 250E 300E 350Z Size 100E 125E 150E 125E 150E 200E 250E 300E 350E 400E 100E 100E 125E 150E 200E 250E Dim. (inches) Dim. (inches) Interrupting Rating (Asym) 15-7/8" 80,000 15-7/8" 80,000 15-7/8" 80,000 Diagram 8.25 Max. 8.25 Max. 100E 100E 125E 150E 200E 17-7/8" 80,000 17-7/8" 80,000 RATED Catalog Number 10E-1C-15.5 15E-1C-15.5 20E-1C-15.5 25E-1C-15.5 30E-1C-15.5 40E-1C-15.5 50E-1C-15.5 65E-1C-15.5 80E-1C-15.5 100E-1C-15.5 65E-2C-15.5 80E-2C-15.5 100E-2C-15.5 125E-2C-15.5 150E-2C-15.5 175E-2C-15.5 200E-2C-15.5 200E-3C-15.5 250E-3C-15.5 300E-3C-15.5 15.5 Max. Catalog Number 100E 150E 175E Size 100E 100E 125E 150E 175E 200E 200E 250E 300E Dim. (inches) Dim. (inches) Interrupting Rating (Asym) 18.875" 60,000 18.875" 60,000 18.875" 60,000 Figure Number Rated Medium Voltage FuseCurrent Limiting RATED Catalog Number 15GSE-65E 15GSE-80E 15GSE-100E 15GSE2-125E 15GSE2-150E 15GSE2-175E 15GSE2-200E 15NLE-10E 15NLE-15E 15NLE-20E 15NLE-25E 15NLE-30E 15NLE-40E 15NLE-50E 15NLE-65E 15NLE-80E 15NLE-100E 15NLE2-80E 15NLE2-100E 15NLE2-125E 15NLE2-150E 15NLE2-175E 15NLE2-200E 15NLE3-150E 15NLE3-175E 15NLE3-250E 15NLE3-300E Catalog Number Size 100E 125E 150E 175E 200E 100E 100E 125E 150E 175E 200E 150E 175E 250E 300E Dim. (inches) Dim. (inches) 21-7/8" Interrupting Rating (Asym) 60,000 21-7/8" 60,000 Figure Number 15.5 Max. 15.5 Max. 80ES 100ES 100E 125X 150E 200ED 23-7/8" 60,000 23-7/8" 60,000 23-7/8" 60,000 RATED Catalog Number 15E-1C-25.8 20E-1C-25.8 25E-1C-25.8 30E-1C-25.8 40E-1C-25.8 50E-1C-25.8 65E-2C-25.8 80E-2C-25.8 100E-2C-25.8 Catalog Number Size 100E Dim. (inches) Dim. (inches) Interrupting Rating (Asym) 24-5/8" 40,000 24-5/8" 40,000 Figure Number 25.8 Max. RATED Catalog Number 3E-1C-38.0 7E-1C-38.0 10E-1C-38.0 15E-1C-38.0 20E-1C-38.0 25E-1C-38.0 30E-1C-38.0 40E-1C-38.0 50E-2C-38.0 65E-2C-38.0 80E-2C-38.0 Catalog Number Size Dim. (inches) Dim. (inches) Interrupting Rating (Asym) 30-5/8" 20,000 30-5/8" 20,000 Figure Number Max. Rated Medium Voltage FuseCurrent Limiting 4.31 7.94 11.56 Clip Lock Design clip lock type designs ensures positive contact between fuse connection cam. fuse's clip lock slides between clip casting prevent fuse from slipping blowing holder. This positive contact improves heat dissipation allows fuses cooler. 1.25 FIGURE FIGURE 1.25 FIGURE Interrupting Rating (Asym) RATED Catalog Number 10E-1CL-5.5 15E-1CL-5.5 20E-1C-5.5 25E-1CL-5.5 30E-1CL-5.5 40E-1CL-5.5 50E-1CL-5.5 65E-1CL-5.5 80E-1CL-5.5 100E-1CL-5.5 125E-1CL-5.5 150E-1CL-5.5 225E-2CL-5.5 250E-2CL-5.5 300E-2CL-5.5 350E-2CL-5.5 400E-2CL-5.5 450E-2CL-5.5 500E-3CL-5.5 550E-3CL-5.5 600E-3CL-5.5 Catalog Number Size 100E 125E 150E 225E 250E 300E 350E 400E 450E 500E 550E 600E Dim. (inches) Dim. (inches) 16.38" 15.13" 80,000 17.38" 16.13" 80,000 17.38" 16.13" 80,000 Figure Number Max. Clip Lock RATED Catalog Number 10E-1CL-8.25 15E-1CL-8.25 20E-1C-8.25 25E-1CL-8.25 30E-1CL-8.25 40E-1CL-8.25 50E-1CL-8.25 65E-1CL-8.25 80E-1CL-8.25 100E-1CL-8.25 125E-2CL-8.25 150E-2CL-8.25 175E-2CL-8.25 200E-2CL-8.25 225E-2CL-8.25 250E-2CL-8.25 300E-2CL-8.25 350E-3CL-8.25 Catalog Number 8.25 Max. Size 100E 125E 150E 175E 200E 225E 250E 300E 350E Dim. (inches) Dim. (inches) Interrupting Rating (Asym) 17.38" 16.13" 80,000 17.38" 16.13" 80,000 17.38" 16.13" 80,000 Interrupting Rating (Asym) Figure Number RATED Clip Lock Catalog Number 10E-1CL-15.5 15E-1CL-15.5 20E-1CL-15.5 25E-1CL-15.5 30E-1CL-15.5 40E-1CL-15.5 50E-1CL-15.5 65E-1CL-15.5 80E-1CL-15.5 100E-1CL-15.5 125E-2CL-15.5 150E-3CL-15.5 175E-3CL-15.5 200E-3CL-15.5 225E-3CL-15.5 250E-3CL-15.5 300E-3CL-15.5 Catalog Number Size 100E 150E 175E 200E 225E 250E 300E Dim. (inches) Dim. (inches) 19.8" 18.1" 60,000 22.81" 22.81" 21.13" 19.1" 60,000 60,000 22.81" 19.1" 60,000 Figure Number 15.5 Max. Clip Lock Rated Potential Transformer FuseCurrent Limiting Potential Transformer (PT) fuses current limiting fuses with high interrupting ratings designed protection potential transformers. Application Note: When applying fuses protection transformers, magnetizing current inrush must considered. characteristics inrush, which matched with fuse's time-current curve, should available from transformer manufacturer. CHARACTERISTICS Voltage Rating: 600VAC 25,500 Current Range: 1/2E Catalog Number 3E-4PT-6 5E-4PT-6 7E-4PT-6 10E-4PT-6 1E-4PT-2.4 2E-4PT-2.4 1E-6PT-2.75 2E-6PT-2.75 3E-6PT-2.75 1E-8PT-2.75 2E-8PT-2.75 3E-8PT-2.75 1E-5PT-4.8 2E-5PT-4.8 1/2E-6PT-5.5 1E-6PT-5.5 2E-6PT-5.5 3E-6PT-5.5 5E-6PT-5.5 1/2E-8PT-5.5 1E-8PT-5.5 2E-8PT-5.5 3E-8PT-5.5 5E-8PT-5.5 10E-8PT-5.5 1/2E-8PT-8.25 1E-8PT-8.25 2E-8PT-8.25 3E-8PT-8.25 1/2E-11PT-15.5 1E-11PT-15.5 2E-11PT-15.5 3E-11PT-15.5 3E-16PT-15.5 5E-16PT-15.5 1/2E-16PT-25.5 1E-16PT-25.5 Catalog Number Size Length Dim. (inches) 4.625 4.625 4.625 4.625 4.625 4.625 7.375 7.375 7.375 7.375 7.375 7.375 7.375 7.375 12.875 12.875 12.875 12.875 17.5 17.5 17.5 17.5 Diameter Dim. (inches) 0.8125 0.8125 0.8125 0.8125 0.8125 0.8125 1.625 1.625 1.625 1.625 1.625 1.625 0.8125 0.8125 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 1.625 Interrupting Rating (Asym) 62,500 62,500 62,500 62,500 40,000 40,000 37,500 37,500 37,500 50,000 50,000 50,000 50,000 50,000 37,500 37,500 37,500 37,500 37,500 37,500 37,500 37,500 37,500 37,500 37,500 50,000 50,000 50,000 50,000 80,000 80,000 80,000 80,000 80,000 80,000 43,500 43,500 Max. Volt 1E-4 2E-4 Max. 2.75 Max. 1E-4 2E-4 1/2E 1/2E 1/2E Max. 8.25 Max. 25.5 Max. 15.5 Max. 1/2E 1/2E 1E-4 2E-4 Live PartLive parts available mounting "E", "R", "PT" single, double, triple barrel fuses. Mounting clips available ferrule type clip lock style fuses. clips sold pairs. Contact factory additional live parts. Part Number: 700-500* with 13/16" diameter fuses. Part Number: 700-530* X1.06 SLOT 1.50 1.56 4.00 with diameter fuses. 1.15 3.08 4.66 Pair Pair Part Number: 700-520-CL* Clip Lock Design (For CL-14) Mounting Details Clip Lock 3.63 TRIPLE BARREL DOUBLE BARREL 3.63 Bottom Lever Closed Position SINGLE BARREL 4.85 Blown Fuse Indicator 2.00 3.75 2.00 Lever Open Position 2.00 1.75 1.00 Dia. Holes Mounting Cable/Bu Pair VIEW DIA. HOLES Other recent searchesMwT-H15 - MwT-H15 MwT-H15 Datasheet MA142WK - MA142WK MA142WK Datasheet LX8211 - LX8211 LX8211 Datasheet CMPTA06 - CMPTA06 CMPTA06 Datasheet CMPTA56 - CMPTA56 CMPTA56 Datasheet 8m052388 - 8m052388 8m052388 Datasheet 2SD1213 - 2SD1213 2SD1213 Datasheet
Privacy Policy | Disclaimer |