Description
Series DC/DC converters feature high power density with derating over full military temperature range. This series offered part complete family converters providing single dual output voltages operating from nominal +28V, +50V, +120V +270 inputs with output power ranging from 120W. applications requiring higher output power, individual converters operated parallel. internal current sharing circuits assure equal current distribution among paralleled converters. This series incorporates International Rectifier's proprietary magnetic pulse feedback technology providing optimum dynamic line load regulation response. This feedback system samples output voltage pulse width modulator fixed clock frequency, nominally KHz. Multiple converters synchronized system clock 500KHz 700KHz range synchronization output converter. Undervoltage lockout, primary secondary referenced inhibit, softstart load fault protection provided models. These converters hermetically packaged enclosure variations, utilizing copper core pins minimize resistive losses. Three lead styles available, each fabricated with International Rectifier's rugged ceramic lead-to-package seal assuring long term hermeticity most harsh environments. Manufactured facility fully qualified MIL-PRF38534, these converters fabricated utilizing DSCC qualified processes. available screening options, refer device screening table data sheet. Variations electrical, mechanical screening accommodated. Contact Santa Clara special requirements.
Features
Input Range ±5V, 12V, ±15V Outputs Available High Power Density 70W/in3 100W Output Power Parallel Operation with Stress Current Sharing Profile (0.380") Seam Welded Package Ceramic Feedthru Copper Core Pins High Efficiency Full Military Temperature Range Continuous Short Circuit Overload Protection Output Voltage Trim Primary Secondary Referenced Inhibit Functions Line Rejection 40dB 50KHz External Synchronization Port Fault Tolerant Design Single Output Versions Available Standard Microcircuit Drawings Available
www.irf.com
12/14/06
AFL50XXD Series
Specifications
Absolute Maximum Ratings
Input voltage Soldering temperature Operating case temperature Storage case temperature -0.5V +50VDC 300°C seconds -55°C +125°C -65°C +135°C
Static Characteristics -55°C TCASE +125°C, 30V< unless otherwise specified.
Parameter INPUT VOLTAGE OUTPUT VOLTAGE AFL5005D AFL5012D AFL5015D AFL5005D AFL5012D AFL5015D OUTPUT CURRENT AFL5005D AFL5012D AFL5015D OUTPUT POWER AFL5005D AFL5012D AFL5015D MAXIMUM CAPACITIVE LOAD OUTPUT VOLTAGE TEMPERATURE COEFFICIENT OUTPUT VOLTAGE REGULATION Line Load Cross AFL5005D AFL5012D AFL5015D Group Subgroups Note Volts, 100% Load Positive Output Negative Output Positive Output Negative Output Positive Output Negative Output Positive Output Negative Output Positive Output Negative Output Positive Output Negative Output Volts Notes Either Output Either Output Either Output Total Both Outputs. Notes 6,11 Test Conditions 4.95 -5.05 11.88 -12.12 14.85 -15.15 4.90 -5.10 11.76 -12.24 14.70 -15.30 5.00 -5.00 12.00 -12.00 15.00 -15.00 5.05 -4.95 12.12 -11.88 15.15 -14.85 5.10 -4.90 12.24 -11.76 15.30 -14.70 12.8 Each Output Note Volts, 100% Load Notes Note Load, Load, 100% Load Volts. Volts. Note Positive Output Negative Output Positive Output Negative Output Positive Output Negative Output 10,000 -0.015 -0.5 -1.0 +0.015 +0.5 +1.0 %/°C Unit
-1.0 -8.0 -1.0 -5.0 -1.0 -5.0 +1.0 +8.0 +1.0 +5.0 +1.0 +5.0
Notes Specifications, refer page
www.irf.com
AFL50XXD Series
Static Characteristics (Continued)
Parameter OUTPUT RIPPLE VOLTAGE AFL5005D AFL5012D AFL5015D INPUT CURRENT Load Inhibit Inhibit INPUT RIPPLE CURRENT AFL5005D AFL5012D AFL5015D CURRENT LIMIT POINT Expressed Percentage Full Rated Load LOAD FAULTPOWER DISSIPATION Overload Short Circuit EFFICIENCY AFL5005D AFL5012D AFL5015D ENABLE INPUTS (Inhibit Function) Converter Sink Current Converter Sink Current SWITCHING FREQUENCY SYNCHRONIZATION INPUT Frequency Range Pulse Amplitude, Pulse Amplitude, Pulse Rise Time Pulse Duty Cycle ISOLATION DEVICE WEIGHT MTBF Volts, 100% Load Group Subgroups Test Conditions Volts, 100% Load, 10MHz Unit
mVpp
Volts IOUT Shorted Shorted Volts, 100% Load
mApp
VOUT VNOM Current split equally positive negative outputs. Note
Volts
-0.5 -0.5
Logical Note Logical High Note Note
Note Note Input Output Case (except Test 500VDC Slight Variations with Case Style MIL-HDBK-217F, 40°C
KHrs
Notes Specifications, refer page
www.irf.com
AFL50XXD Series
Dynamic Characteristics -55°C TCASE +125°C, VIN=50V unless otherwise specified.
Parameter LOAD TRANSIENT RESPONSE AFL5005D Either Output Amplitude Recovery Amplitude Recovery Group Subgroups Note Load Step 100% Load Step Load Step 100% Load Step Load Step 100% Load Step Note Step Volts Note Enable (Pins high open) Same Turn Characteristics. MIL-STD-461D, CS101, 30Hz 50KHz Note -500 -450 -450 Test Conditions Unit
AFL5012D Either Output
Amplitude Recovery Amplitude Recovery
-750 -750
AFL5015D Either Output
Amplitude Recovery Amplitude Recovery
-750 -750
LINE TRANSIENT RESPONSE Amplitude Recovery TURN-ON CHARACTERISTICS Overshoot Delay LOAD FAULT RECOVERY LINE REJECTION
Notes Specifications:
Parameters 100% tested guaranteed limits specified table. Recovery time measured from initiation transient where VOUT returned within VOUT load. Line transient transition time 100µs. Turn-on delay measured with input voltage rise time between 100V 500V millisecond. Current limit point that condition excess load causing output voltage drop nominal. Parameter verified part another test. electrical tests performed with remote sense leads connected output leads load. Load transient transition time 10µs. Enable inputs internally pulled high. Nominal open circuit voltage 4.0VDC. Load current split equally between +Vout Output load must distributed that minimum total output power being provided outputs. Cross regulation measured with load tested output while changing load other output from 80%.
www.irf.com
AFL50XXD Series
Block Diagram
Figure Dual Output
INPUT INPUT FILTER OUTPUT FILTER PRIMARY BIAS SUPPLY OUTPUT
ENABLE
CURRENT SENSE
OUTPUT RETURN
OUTPUT FILTER SYNC OUTPUT CONTROL SYNC INPUT
OUTPUT
SHARE ERROR AMPLIFIER
SHARE ENABLE OUTPUT VOLTAGE TRIM
CASE
INPUT RETURN
Circuit Operation Application Information
series converters employ forward switched mode converter topology. (refer Figure Operation device initiated when voltage whose magnitude within specified input limits applied between pins pins enabled logical open) primary bias supply will begin generating regulated housekeeping voltage bringing circuitry primary side converter life. power MOSFETs used chop input voltage into high frequency square wave, apply this chopped voltage power transformer. this switching initiated, voltage impressed second winding power transformer which then rectified applied primary bias supply. When this occurs, input voltage excluded from bias voltage generator primary bias voltage becomes internally generated. switched voltage impressed secondary output transformer windings rectified filtered provide positive negative converter output voltages. error amplifier secondary side compares positive output voltage precision reference generates error signal proportional difference. This error signal magnetically coupled through feedback transformer into control section converter varying pulse width square wave signal driving MOSFETs, narrowing pulse width output voltage high widening low. These pulse width variations provide necessary corrections maintain magnitude output voltage within its' specified limits. Because primary secondary sides coupled magnetic elements, full isolation from input output achieved.
Although incorporating several sophisticated useful ancillary features, basic operation AFL50XXD series initiated simply applying input voltage pins connecting appropriate loads between pins course, operation anyconverter with high power density should attempted before secure attachment appropriate heat dissipator. (See Thermal Considerations, page
Inhibiting Converter Output (Enable)
alternative application removal voltage input, user control converter output providing compatible, positive logic signals either enable pins (pin 12). distinction between these signal ports that enable (pin referenced input return (pin while enable (pin referenced output return (pin Thus, user access inhibit function either side isolation barrier. Each port internally pulled "high" that when used, open connection both enable pins permits normal converter operation. When their desired, logical "low" either port will shut converter down.
Figure Enable Input Equivalent Circuit
+5.6 100K
1N4148
290K 2N3904 180K
Disable
www.irf.com
AFL50XXD Series
Internally, these ports differ slightly their function. use, Enable completely shuts down circuits converter, while Enable shuts down secondary side while altering controller duty cycle near zero. Externally, either port transparent user save minor differences idle current. (See specification table). level +2.0V. sync output another converter which been designated master oscillator provides convenient frequency source this mode operation. When external synchronization required, sync should left unconnected thereby permitting converter operate its' internally frequency. sync output signal continuous pulse train 50KHz, with duty cycle 5.0%. This signal referenced input return been tailored compatible with sync input port. Transition times less than 100ns level output impedance less than This signal active when input voltage within specified operating range converter inhibited. sync output adequate drive reserve synchronize least five additional converters. typical connection illustrated Figure III.
Synchronization Multiple Converters
When operating multiple converters, system requirements often dictate operation converters common frequency. accommodate this requirement, series converters provide both synchronization input output. sync input port permits synchronization converter compatible external frequency source operating between 500KHz 700KHz. This input signal should referenced input return have duty cycle. Compatibility requires transition times less than 100ns, maximum level +0.8V minimum high
Figure III. Preferred Connection Parallel Operation
Power Input
Case Enable Sync Sync
Enable
Share Trim Output Return Output
Optional Synchronization Connection
Share
Case Enable Sync Sync
Enable Share
Trim Output Return Output
Negative Load Positive Load
Case Enable Sync Sync
Enable
Share Trim Output Return Output
(Other Converters)
Parallel Operation-Current Stress Sharing
Figure III. illustrates preferred connection scheme operation converters with outputs operating parallel. this connection permits equal current sharing among members whose load current exceeds capacity individual AFL. important
feature series operating parallel mode that addition sharing current, stress induced temperature will also shared. Thus member paralleled operating higher case temperature, current provides load will reduced compenstionfor temperature induced stress that device.
www.irf.com
AFL50XXD Series
When operating shared mode, important that symmetry connection maintained assurance optimum load sharing performance. Thus, converter outputs should connected load with equal lengths wire same gauge sense leads from each converter should connected common physical point, preferably load along with converter output return leads. converters paralleled must have their share pins connected together. This arrangement diagrammatically illustrated Figure III. showing outputs return pins connected star point which located close possible load. consequence topology utilized current sharing circuit, share used other functions. applications requiring only single converter, voltage appearing share used "current monitor". share open circuit voltage nominally +1.00V load increases linearly with increasing output current +2.20V full load. Note that current refer here total device output current, that positive negative output currents. conservative estimating total heat sink surface area HEAT SINK required maximum case temperature rise above ambient temperature given following expression:
-143 HEAT SINK 0.85
where
Case temperature rise above ambient Device dissipation Watts POUT
example, desired maintain case temperature AFL5015D +85°C while operating open area whose ambient temperature held constant +25°C; then
Thermal Considerations
Because incorporation many innovative technological concepts, series converters capable providing very high output power from package very small volume. These magnitudes power density only obtained combining high circuit efficiency with effective methods heat removal from junctions. This requirement been effectively addressed inside device; when operating maximum loads, significant amount heat will generated this heat must conducted away from case. maintain case temperature below specified maximum 125°C, this heat must transferred conduction appropriate heat dissipater held intimate contact with converter base-plate. Since effectiveness this heat transfer dependent intimacy baseplate/heatsink interface, strongly recommended that high thermal conductivity heat transferring medium inserted between baseplate heatsink. material most frequently utilized factory during testing burn-in processes sold under trade name Sil-Pad® 4001 This particular product insulator electrically conductive versions also available. these materials assures maximum surface contact with heat dissipater thereby compensating minor surface variations. While other available types heat conductive materials thermal compounds provide similareffectiveness, these alternatives often less convenient somewhat messy use.
1Sil-Pad registered Trade Mark Bergquist, Minneapolis,
60°C
worst case full load efficiency this device 100W; then power dissipation full load given
(0.205) 20.5W
required heat sink area
HEAT SINK 0.85 20.5
-1.43
56.3
Thus, total heat sink surface area (including fins, any) this example, would limit case rise 60°C above ambient. flat aluminum plate, 0.25" thick approximate dimension side) would suffice this application still environment. Note that meet criteria this example, both sides plate require unrestricted exposure +25°C ambient air.
www.irf.com
AFL50XXD Series
Input Filter
AFL50XXD series converters incorporate single stage input filter whose elements dominate input load impedance characteristic during turn-on. input circuit shown Figure
Table Output Voltage Trim Values Limits
AFL5005D Vout 4.583 Radj 12.5K 33.3K 200K 190K 2.5K AFL5012D Vout 12.5 12.4 12.3 12.2 12.1 12.0 11.7 11.3 10.8 10.6 10.417 Radj 47.5K 127K 285K 760K 975K 288K 72.9K 29.9K AFL5015D Vout 15.5 15.4 15.3 15.2 15.1 15.0 14.6 14.0 13.5 13.0 12.917 Radj 62.5K 167K 375K 1.0M 1.2M 325K 117K 12.5K
Figure Input Filter Circuit
0.75µH 2.7µfd
Undervoltage Lockout
minimum voltage required input converter initiate operation. This voltage 26.5 1.5V. preclude possibility noise other variations input falsely initiating halting converter operation, hysteresis approximately 2.0V incorporated this circuit. Thus input voltage droops 24.5 1.5V, converter will shut down remain inoperative until input voltage returns 25V. Note that nominal magnitude output voltage resides middle table corresponding resistor value magnitude above nominal, adjust resistor connected output return. magnitude below nominal, adjust resistor connected positive output. (Refer Figure output voltage settings that within limits, between those presented Table suggested that resistor values determined empirically selection variable resistor. value thus determined then replaced with good quality fixed resistor permanent installation. When trim feature elected, user should aware that temperature performance converter output voltage will affected temperature performance resistor selected adjustment element therefore, user advised employ resistors with very small temperature coefficient resistance.
Output Voltage Adjust
trim (10), magnitude output voltages adjusted over limited range either positive negative direction. Connecting resistor between trim either output return positive output will raise lower magnitude output voltage. span output voltage magnitude restricted limits shown Table
Figure Connection VOUT Adjustment
Enable Share
AFL50xxD
Trim Vout Return Vout
RADJ
Loads
Connect Radj increase, decrease.
www.irf.com
AFL50XXD Series
Mechanical Outlines
Case Case
Variation Case
3.000 2.760
0.128
0.050 0.250
0.250 0.050
0.25
BERYLLIA WARNING: These converters hermetically sealed; however they contain substrates should ground subjected other operations including exposure acids, which produce Beryllium dust fumes containing Beryllium
www.irf.com
1.260 1.500
1.000
0.200 Non-cum 0.040
1.000
2.500
0.220
0.220 2.800 0.525
0.040
2.975 0.238
0.42
0.380
0.380
Case
1.150 0.300 0.140 0.050
Case
Variation Case
0.050
0.250
0.250
1.500 1.750 2.00
1.000
0.200 Non-cum 0.040
1.000
0.040 0.220 0.36 2.800 0.525
1.750 2.500 2.975 0.238
0.375
0.220
0.380
0.380
Tolerances, unless otherwise specified:
.XXX
±0.010 ±0.005
AFL50XXD Series
Designation
Designation Input Input Return Case Ground Enable Sync Output Sync Input Output Output Return Output Output Voltage Trim Share Enable
Standard Microcircuit Drawing Equivalence Table
Standard Microcircuit Drawing Number
5962-02563 5962-02564 5962-02565
Standard Part Number
AFL5005D AFL5012D AFL5015D
www.irf.com
AFL50XXD Series
Device Screening
Requirement
Temperature Range Element Evaluation Non-Destructive Bond Pull Internal Visual Temperature Cycle Constant Acceleration PIND Burn-In Final Electrical Group Seal, Fine Gross Radiographic External Visual MIL-PRF-38534 2023 2017 1010 2001, Axis 2020 1015 MIL-PRF-38534 Specification MIL-PRF-38534 1014 2012 2009 Cond Cond
MIL-STD-883 Method
Suffix
-55°C +125°C Class Cond 3000 -55°C, +25°C, +125°C Cond
-20°C +85°C -55°C +125°C Cond
-55°C +125°C
Cond 3000 -55°C, +25°C, +125°C Cond
25°C
hrs@hi temp 25°C
hrs@125°C hrs@125°C
Notes:
Best commercial practice Sample tests high temperatures -55°C +105°C AHE, ATO,
Part Numbering
Model Input Voltage
120V 270V
Screening Level
(Please refer Screening Table)
suffix,
Case Style
Output
Dual
Output Voltage
±12V ±15V
WORLD HEADQUARTERS: Kansas St., Segundo, California 90245, Tel: (310) 3331 SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500 Visit www.irf.com sales contact information. Data specifications subject change without notice. 12/2006
www.irf.com

Other recent searches


SILM730 - SILM730   SILM730 Datasheet
ROV10 - ROV10   ROV10 Datasheet
ROV10H - ROV10H   ROV10H Datasheet
BH1603FVC - BH1603FVC   BH1603FVC Datasheet
B69813N1967M460 - B69813N1967M460   B69813N1967M460 Datasheet
ATC18RHA - ATC18RHA   ATC18RHA Datasheet
AM29F400T - AM29F400T   AM29F400T Datasheet
2SB1657 - 2SB1657   2SB1657 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive