LPT40 Series
Total Power: Input Voltage: Outputs: Watts 300VDC Triple
Rev. 02.05.07 LPT40 Series
RoHS
Electrical Specifications
Special Features
Universal input footprint Less than high Remote sense main output Terminal Block option (-T) Built-in filter output ripple Adjustable main output Overvoltage protection Overload protection switching frequency LPX40 enclosure available
Input
Input range Frequency Inrush current Input current Efficiency 85-264 120-300 47-440 <18A peak 115VAC; <36A peak 230VAC, cold start 25°C max. (RMS) 115VAC typical full load (60% LPT41) Class conducted; CISPR Class conducted EN55022 Class conducted; 0878 Class conducted <0.5 50/60 input
Safety ground leakage current
Output
Maximum Power Cross regulation Adjustment range Hold-up time Overload protection Overvoltage protection Remote sense convection (LPT41, 25W); with 30CFW forced (LPT41, 41W) output outputs +10% minimum 20ms load, nominal line Short circuit protection outputs. Case overload protected 110% 145% above peak rating main output LPT41: 4.6VDC Compensates lead drop min. Will operate without remote sense connected. Reverse connection protected.
Safety
UL60950 E132002 22.2-234 Level LR53982C NEMKO 60950/EMKO-TUE P95100411 (74-sec) Certificate report 1118, 1122, 1123, 1124 Mark (LVD)
Environmental Specifications
Operating temperature: Electromagnetic susceptibility: Humidity: Vibration: 50°C ambient derate each output 2.5% degree from 70°C, -20°C start Designed meet 801, Level Operating; non-condensing Three orthogonal axes, sweep oct/min, min. dwell four major resonances 0.75G peak operational -40° 85°C ±.04% >550,000 hours full load 25°C ambient conditions
Rev. 02.05.07 LPT40 Series
Storage temperature: Temperature coefficient: MTBF demonstrated:
Ordering Information
Model Number LPT41(-T) Output Voltage +3.3V +12V +12V -12V +12V -12V +12V +15V -15V +24V +12V +24V -12V Minimum Load 0.5A 0.4A 0.2A 0.5A 0.4A 0.2A 0.4A 0.2A 0.4A 0.1A 0.4A 0.2A Maximum Load with Convnection cooling 1.5A 0.5A 0.5A 0.5A 0.5A 0.5A 0.5A 1.0A 0.5A 1.0A 0.5A Maximum Load with 30CFM Forced 2.0A 0.7A 2.5A 0.7A 0.7A 0.7A 2.5A 0.7A 2.5A 0.7A 1.5A 0.7A 1.5A 0.7A Peak Load1 2.5A 0.7A Regulation2 Ripple (PARD)3 50mV 50mV 120mV 50mV 120mV 120mV 50mV 120mV 120mV 50mV 120mV 50mV 50mV 150mV 150mV 50mV 240mV 120mV 50mV 240mV 120mV
LPT42(-T)
LPT43(-T)
LPT44(-T)
LPT45(-T)
LPT46(-T)
LPT47(-T)
Peak current lasting seconds with maximum duty cycle. 25°C including initial tolerance, line voltage, load currents output voltages adjusted factory settings. Peak-to-peak with bandwidth parallel with capacitor rated line voltage load ranges. Minimum Loads required. (-T) indicates Terminal Block option input output (instead Molex type)
Power Derating Curve
Forced Cooling
Output Power (Watts)
Natural Convection Cooling
27.5W
10°C 20°C 30°C 40°C 50°C 60°C 70°C Ambient Temperature
Mechanical Drawing
5.00" (127)
Astec
5810 Allen Carlsbad, 92008 Telephone: 4600 Facsimile: 0698
Rev. 02.05.07 LPT40 Series
0.22" (5.6)
4.55" (115.6)
SK201
3.00" (76.2) 2.55" (64.8)
Remote Sense Connector Voltage Adj.
Waterfront Business Park Merry Hill, Dudley West Midlands, United Kingdom Telephone: 1384 Facsimile: 1384 13-15, Shing Road Wai, Shatin, Hong Kong Telephone: +852 2699 2868 Facsimile: +852 2699 1770
0.15" places) 1.14" (29)
global contact, visit:
www.astecpower.com technicalsupport@astec.com
While every precaution been taken ensure accuracy completeness this literature, Emerson Network Power assumes responsibility, disclaims liability damages resulting from this information errors omissions.
0.197"
Assignments
Connector LPT41 SK1-1 SK1-3 SK2-1 SK2- SK2- SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 Line Neutral 3.3V 3.3V Common Common +Sense -Sense LPT42 Line Neutral +12V Common Common -12V +Sense -Sense LPT43 Line Neutral +12V Common Common -12V +Sense -Sense LPT44 Line Neutral +12V Common Common +Sense -Sense LPT45 Line Neutral +15V Common Common -15V +Sense -Sense LPT46 Line Neutral +24V Common Common +12V +Sense -Sense LPT47 Line Neutral +24V Common Common -12V +Sense -Sense
Emerson Network Power. global leader enabling business-critical continuity. Power Connectivity Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring Services EmersonNetworkPower.
Emerson Network Power Emerson Network Power logo trademarks service marks Emerson Electric ©2007 Emerson Electric
Mating Connectors
Input: Outputs: Molex 09-50-8031 (USA) required (-T) option 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA) required (-T) option 09-91-0600 (UK) PINS: 08-52-0113
Remote Sense: Molex 22-01-2025 PINS: 08-52-0123 Astec Connector #70-841-006, includes above Specifications subject change without notice. dimensions inches (mm), tolerance ±0.02" (±0.5mm) Mounting holes should grounded purposes. Mounting hole safety ground connection. Specifications convection rating factory settings input, 25°C unless otherwise stated. Warranty: year Weight: 0.5lbs/0.23kg

Other recent searches


Si5515DC - Si5515DC   Si5515DC Datasheet
MPS3906 - MPS3906   MPS3906 Datasheet
MIC2564A - MIC2564A   MIC2564A Datasheet
LTC3406 - LTC3406   LTC3406 Datasheet
LTC3406-1 - LTC3406-1   LTC3406-1 Datasheet
DV2005L1 - DV2005L1   DV2005L1 Datasheet
bq2005 - bq2005   bq2005 Datasheet
CY8C29466 - CY8C29466   CY8C29466 Datasheet
CY8C29566 - CY8C29566   CY8C29566 Datasheet
CY8C29666 - CY8C29666   CY8C29666 Datasheet
CY8C29866 - CY8C29866   CY8C29866 Datasheet
2SK3443 - 2SK3443   2SK3443 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive