| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Total Power: Input Voltage: Outputs: Watts 300VDC Single Rev. 02.
Top Searches for this datasheetLPS60 Series Total Power: Input Voltage: Outputs: Watts 300VDC Single Rev. 02.05.07 LPS60 Series RoHS Electrical Specifications Special Features Universal input footprint Remote sense Built filter output ripple Adjustable output voltage Overload protection switching frequency LPX60 enclosure available Input Input range Frequency Inrush current Input current Efficiency filter Safety ground leakage current (wide range) 300VDC 47-440 <18A peak 115VAC, peak @230 VAC, cold start 25°C 1.5A max. (RMS) typical full load Class conducted; CISPR22 Class conducted; EN55022 Class conducted; VDE0878PT3 Class conducted <0.5mA 50/60 264VAC input Output Maximum power Adjustment range Hold-up time Overload protection convection; with 30CFM forced +10% minimum 20ms load, 115VAC nominal line Safety 0805/EN60950 (IEC950) 11774-3336-1255 #86665) UL1950 E132002 22.2-234 Level LR53982C NEMKO 60950/EMKO-TUE P95100123 (74-sec) Certificate report 1521, 1522, 1523, 1524 Mark (LVD) Short circuit protection outputs. Case overload protected 110-145% above peak rating Overvoltage protection output; 6.7VDC. Other outputs above nominal output Remote sense Compensates 0.5V lead drop min. Will operate without remote sense connected. Reverse connection protected. Environmental Specifications Operating temperature: 50°C ambient derate each output 2.5% degree from 70°C, -20°C startup Storage temperature: Electromagnetic susceptibility: Humidity: Vibration: -40°C +85°C designed meet IEC801, Level Operating; non-condensing Three orthogonal axes, sweep 1cot/min, min. dwell four major resonances 0.75G peak 500Hz, operational >550,000 hours full load 25°C ambient conditions Power Derating Curve Forced Cooling Output Power (Watts) Rev. 02.05.07 LPS60 Series Natural Convection Cooling Temperature coefficient ±0.04% MTBF demonstrated 10°C 20°C 30°C 40°C 50°C 60°C 70°C Ambient Temperature Mechanical Drawing 0.22" (5.6) SK201 Remote Sense Connector Voltage Adj. 3.00" (76.2) 2.55" (64.8) 0.22" (5.6) 4.56" (115.8) 0.15" places) 5.00" (127) 1.69" (42.9) 0.12" Ordering Information Model Number LPS61 LPS62 LPS63 LPS64 LPS65 LPS68 Output Voltage 3.3V Maximum Load Minimum with Convection Load Cooling 2.5A 1.3A Maximum Load with 30CFM forced 6.7A 5.3A 3.3A 1.7A Peak Regulation2 Load1 7.5A 3.8A 1.9A Ripple (PARD)3 33mV 50mV 120mV 150mV 240mV 480mV Astec 5810 Allen Carlsbad, 92008 Telephone: 4600 Facsimile: 0698 Waterfront Business Park Merry Hill, Dudley West Midlands, United Kingdom Telephone: 1384 Facsimile: 1384 13-15, Shing Road Wai, Shatin, Hong Kong Telephone: +852 2699 2868 Facsimile: +852 2699 1770 Rev. 02.05.07 LPS50 Series Peak current lasting seconds with maximum duty cycle. 25°C including initial tolerance, line voltage, load currents output voltages adjusted factory settings. Peak-to-peak with bandwidth (tantalum capacitor) parallel with capacitor rated line voltage load ranges. Assignments Connector LPS61 SK1-1 SK1-3 SK2-1 SK2- SK2- SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 Neutral Line 3.3V 3.3V 3.3V Common Common Common +Sense -Sense LPS62 Neutral Line +12V +12V +12V Common Common Common +Sense -Sense LPS63 Neutral Line +15V +15V +15V Common Common Common +Sense -Sense LPS65 Neutral Line Common Common Common +Sense -Sense LPS66 Neutral Line Common Common Common +Sense -Sense global contact, visit: www.astecpower.com technicalsupport@astec.com While every precaution been taken ensure accuracy completeness this literature, Emerson Network Power assumes responsibility, disclaims liability damages resulting from this information errors omissions. Mating Connectors Input: Outputs: Molex 09-50-8031 (USA) required (-T) option 09-91-0300 (UK) PINS: 08-58-0111 Molex 09-50-8061 (USA) required (-T) option 09-91-0600 (UK) PINS: 08-58-0113 Remote Sense: Molex 22-01-2025 PINS: 08-52-0113 Astec Connector #70-841-006, includes above Specifications subject change without notice. dimensions inches (mm), tolerance ±0.02" (±0.5mm) Mounting holes should grounded purposes. Mounting hole safety ground connection. Specifications convection rating factory settings input, 25°C unless otherwise stated. Warranty: year Weight: 0.75lbs/0.34kg Emerson Network Power. global leader enabling business-critical continuity. Power Connectivity Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring Services EmersonNetworkPower. Emerson Network Power Emerson Network Power logo trademarks service marks Emerson Electric ©2007 Emerson Electric Other recent searchesTDA7407D - TDA7407D TDA7407D Datasheet LAD945GSEJT - LAD945GSEJT LAD945GSEJT Datasheet LA38B-66 - LA38B-66 LA38B-66 Datasheet HMC494LP3 - HMC494LP3 HMC494LP3 Datasheet HER101 - HER101 HER101 Datasheet HER105 - HER105 HER105 Datasheet HDM64GS12 - HDM64GS12 HDM64GS12 Datasheet BAP51-02 - BAP51-02 BAP51-02 Datasheet ADS5102 - ADS5102 ADS5102 Datasheet ADS5103 - ADS5103 ADS5103 Datasheet 1696810000 - 1696810000 1696810000 Datasheet
Privacy Policy | Disclaimer |