The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Total Power: Input Voltage: Outputs: Watts 300VDC Single Rev. 02.


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



LPS60 Series
Total Power: Input Voltage: Outputs: Watts 300VDC Single
Rev. 02.05.07 LPS60 Series
RoHS
Electrical Specifications
Special Features
Universal input footprint Remote sense Built filter output ripple Adjustable output voltage Overload protection switching frequency LPX60 enclosure available
Input
Input range Frequency Inrush current Input current Efficiency filter Safety ground leakage current (wide range) 300VDC 47-440 <18A peak 115VAC, peak @230 VAC, cold start 25°C 1.5A max. (RMS) typical full load Class conducted; CISPR22 Class conducted; EN55022 Class conducted; VDE0878PT3 Class conducted <0.5mA 50/60 264VAC input
Output
Maximum power Adjustment range Hold-up time Overload protection convection; with 30CFM forced +10% minimum 20ms load, 115VAC nominal line
Safety
0805/EN60950 (IEC950) 11774-3336-1255 #86665) UL1950 E132002 22.2-234 Level LR53982C NEMKO 60950/EMKO-TUE P95100123 (74-sec) Certificate report 1521, 1522, 1523, 1524 Mark (LVD)
Short circuit protection outputs. Case overload protected 110-145% above peak rating Overvoltage protection output; 6.7VDC. Other outputs above nominal output Remote sense Compensates 0.5V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Environmental Specifications
Operating temperature: 50°C ambient derate each output 2.5% degree from 70°C, -20°C startup Storage temperature: Electromagnetic susceptibility: Humidity: Vibration: -40°C +85°C designed meet IEC801, Level Operating; non-condensing Three orthogonal axes, sweep 1cot/min, min. dwell four major resonances 0.75G peak 500Hz, operational >550,000 hours full load 25°C ambient conditions
Power Derating Curve
Forced Cooling Output Power (Watts)
Rev. 02.05.07 LPS60 Series
Natural Convection Cooling
Temperature coefficient ±0.04% MTBF demonstrated
10°C 20°C 30°C 40°C 50°C 60°C 70°C Ambient Temperature
Mechanical Drawing
0.22" (5.6)
SK201
Remote Sense Connector Voltage Adj.
3.00" (76.2) 2.55" (64.8)
0.22" (5.6)
4.56" (115.8)
0.15" places) 5.00" (127)
1.69" (42.9)
0.12"
Ordering Information
Model Number LPS61 LPS62 LPS63 LPS64 LPS65 LPS68 Output Voltage 3.3V Maximum Load Minimum with Convection Load Cooling 2.5A 1.3A Maximum Load with 30CFM forced 6.7A 5.3A 3.3A 1.7A Peak Regulation2 Load1 7.5A 3.8A 1.9A Ripple (PARD)3 33mV 50mV 120mV 150mV 240mV 480mV
Astec
5810 Allen Carlsbad, 92008 Telephone: 4600 Facsimile: 0698 Waterfront Business Park Merry Hill, Dudley West Midlands, United Kingdom Telephone: 1384 Facsimile: 1384 13-15, Shing Road Wai, Shatin, Hong Kong Telephone: +852 2699 2868 Facsimile: +852 2699 1770
Rev. 02.05.07 LPS50 Series
Peak current lasting seconds with maximum duty cycle. 25°C including initial tolerance, line voltage, load currents output voltages adjusted factory settings. Peak-to-peak with bandwidth (tantalum capacitor) parallel with capacitor rated line voltage load ranges.
Assignments
Connector LPS61 SK1-1 SK1-3 SK2-1 SK2- SK2- SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 Neutral Line 3.3V 3.3V 3.3V Common Common Common +Sense -Sense LPS62 Neutral Line +12V +12V +12V Common Common Common +Sense -Sense LPS63 Neutral Line +15V +15V +15V Common Common Common +Sense -Sense LPS65 Neutral Line Common Common Common +Sense -Sense LPS66 Neutral Line Common Common Common +Sense -Sense
global contact, visit:
www.astecpower.com technicalsupport@astec.com
While every precaution been taken ensure accuracy completeness this literature, Emerson Network Power assumes responsibility, disclaims liability damages resulting from this information errors omissions.
Mating Connectors
Input: Outputs: Molex 09-50-8031 (USA) required (-T) option 09-91-0300 (UK) PINS: 08-58-0111 Molex 09-50-8061 (USA) required (-T) option 09-91-0600 (UK) PINS: 08-58-0113
Remote Sense: Molex 22-01-2025 PINS: 08-52-0113 Astec Connector #70-841-006, includes above Specifications subject change without notice. dimensions inches (mm), tolerance ±0.02" (±0.5mm) Mounting holes should grounded purposes. Mounting hole safety ground connection. Specifications convection rating factory settings input, 25°C unless otherwise stated. Warranty: year Weight: 0.75lbs/0.34kg
Emerson Network Power. global leader enabling business-critical continuity. Power Connectivity Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring Services EmersonNetworkPower.
Emerson Network Power Emerson Network Power logo trademarks service marks Emerson Electric ©2007 Emerson Electric

Other recent searches


TDA7407D - TDA7407D   TDA7407D Datasheet
LAD945GSEJT - LAD945GSEJT   LAD945GSEJT Datasheet
LA38B-66 - LA38B-66   LA38B-66 Datasheet
HMC494LP3 - HMC494LP3   HMC494LP3 Datasheet
HER101 - HER101   HER101 Datasheet
HER105 - HER105   HER105 Datasheet
HDM64GS12 - HDM64GS12   HDM64GS12 Datasheet
BAP51-02 - BAP51-02   BAP51-02 Datasheet
ADS5102 - ADS5102   ADS5102 Datasheet
ADS5103 - ADS5103   ADS5103 Datasheet
1696810000 - 1696810000   1696810000 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive