| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
200V Pulse Output 10kW Peak Output Power
Top Searches for this datasheet200V Pulse Output 10kW Peak Output Power <100ns Rise Fall Times <200ns Pulse Width 50KHz Pulse Repetition Frequency Protected Against Arcs, Shorts Load Transients Integral Voltage Current Monitor Outputs Optimized Drive Loads From PVX-2110 high power pulse generator (pulsed voltage source) designed pulsing impedance loads (from 200V 50A, with pulse widths from 200ns 2ms. exceptional pulse fidelity PVX-2110 will optimize performance system which used. PVX-2110 deliver 10kW peak output power average output power, making well suited materials testing processing, semiconductor testing characterization, other test measurement applications. PVX-2110 requires gate signal high voltage power supply inputs. output pulse width frequency controlled gate signal. pulse output voltage controlled amplitude input power supply. PVX-2110 features front panel indicator LEDs monitor status pulse generator. Front panel voltage current monitors provide straightforward means view output voltage current waveforms realtime, eliminating need external high voltage oscilloscope probe. output cable supplied with unit innovative custom designed multi-coaxial cable with impedance design this cable maintains fidelity output pulse without introducing pulse distortion ringing, provides convenient means connecting pulse generator load. PVX-2110 over-current detection shut-down circuitry protect pulse generator from potential damage over-current conditions such arcs shorts load interconnect cable. over-current condition detected, output pulse truncated milliseconds. pulse generator then automatically reenables output, will continue pulsing, unless over-current condition persists. also protected against operation excessive pulse widths frequencies. pulse generator direct-coupled, air-cooled solidstate design, offering fast pulse rise fall times, power dissipation, virtually over-shoot, under-shoot ringing. control protection logic circuitry, support power, energy storage output network incorporated into PVX-2110. connected directly load, does require series shunt resistors, impedancematching networks between pulse generator load, additional energy storage (capacitor banks). this taken care within PVX-2110. DIRECTED ENERGY INCORPORATED SPECIFICATIONS (All specifications measured into load connected with feet (~1.2M) cable provided with PVX-2110) OUTPUT Output Voltage Polarity Maximum Value Minimum Value Means Adjustment Maximum Output Current Pulse Rise Fall Time Pulse Width Pulse Recurrence Frequency (PRF) Max. Peak Output Power Max. Average Output Power Max. Duty Cycle Droop Output Current) Over/undershoot Jitter Output Connector Cable INPUT VOLTAGE Input Voltage Polarity Maximum Value Minimum Value Maximum Input Power Input Connector GATE Gate Source Input Gate Connector Positive Negative, Factory Configured Volts Volts Controlled Power Supply Input Voltage Peak, Average <100ns (10% 90%) <200ns 2ms, Controlled Input Gate Single shot 50KHz, Controlled Input Gate 10,000W 5,000W pulse width, <10% pulse width <10ns shot-to-shot Type With feet (~1.2M) Coaxial Cable <50ns Rise Time, 200V Output (25ns/Div horizontal scale, 50V/Div vertical scale) 200ns Minimum Pulse Width, 200V Output (100ns/Div horizontal scale, 50V/Div vertical scale) Positive Negative (User-supplied) Volts Volts 5,000W Type Rear Panel into BNC, Front Panel VOLTAGE CURRENT MONITORS Voltage Monitor 50:1 into accuracy typically within actual output voltage Voltage Monitor Connector BNC, Front Panel Current Monitor Current Monitor Connector GENERAL Support Power 10A/V into accuracy typically within actual output current BNC, Front Panel 90VAC 240VAC, 50/60Hz Typical Output Waveform, 200V (10µs/Div horizontal scale, 50V/Div vertical scale) Dimensions (Excluding Connec- 5.2" (48.25cm 13.2cm tors) 41cm Weight (Approximate) lbs. (8.2 Kilograms) SPECIFICATIONS SUBJECT CHANGE WITHOUT NOTICE Load, 10µs/Div horizontal scale, 50V/Div vertical scale) 50KHz, Duty Cycle, 200V Output When driving loads with impedances output voltage must limited <200V, that peak output current (V/R) does exceed 50A, maximum average current (defined Duty Cycle) does exceed 25A. Peak output power defined during output pulse. Average output power defined Duty Cycle. Input power supply must same polarity PVX-2110 (i.e. positive output PVX-2110 requires positive high voltage input). #9200-0216 Directed Energy, Inc. 2000 Directed Energy, Inc. IXYS Company 2401 Research Blvd., Suite Fort Collins, 80526 970-493-1901 Fax: 970-493-1903 Email: deiinfo@directedenergy.com Web: http://www.directedenergy.com Other recent searchesTPA321 - TPA321 TPA321 Datasheet SS51T - SS51T SS51T Datasheet SN74LV04A - SN74LV04A SN74LV04A Datasheet SN54LV04A - SN54LV04A SN54LV04A Datasheet Si5975DC - Si5975DC Si5975DC Datasheet MR27T12802L - MR27T12802L MR27T12802L Datasheet LM111 - LM111 LM111 Datasheet LM211 - LM211 LM211 Datasheet LM311 - LM311 LM311 Datasheet HMS25632J2 - HMS25632J2 HMS25632J2 Datasheet FSTU3253 - FSTU3253 FSTU3253 Datasheet
Privacy Policy | Disclaimer |