SERIES FEATURES Switching Power Modules Mounting Fully Encapsulat


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Encapsulated AC-DC Converter
SERIES FEATURES
Switching Power Modules Mounting Fully Encapsulated Plastic Case Universal Input Range 90-260VAC, 47-440 Regulated Output Ripple Noise High Efficiency cUL, TUV, Approvals 2-Year Product Warranty
Watts
ELECTRICAL SPECIFICATIONS
Model Single Output output wattage Voltage Frequency (Hz) Input Current (Full load) Inrush current (<2ms) Leakage Current External fuse (recommend) Voltage (V.DC.) Voltage accuracy Current (mA) Line regulation (typ.) Load regulation (5-00%) (typ.) Output Minimum load Maximum capacitive load Ripple Noise Efficiency Hold-up time Switching frequency Over current protection Protection Isolation Over voltage protection Short circuit protection Input-Output (V.AC) Operating temperature Storage temperature Environment Temperature coefficient Humidity MTBF Dimension Physical Case Material Weight Cooling method Safety Agency approvals (Conducted Radiated Emission) (Noise Immunity) ASC-3.3S 47-440 max. (115 VAC) max. (230 VAC) max. (115 VAC) max. (230 VAC) 0.75 max. slow blow type 3.3V 6000 6000 ±1%. 2500 2000 1250 ASC-5S ASC-12S ASC-15S ASC-24S
90-260 120-370
470-23,000µF depending model <0.5% Vout +50mV (Vp-p) min. Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000 -25°C.+71°C -40°C.+85°C 0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C >200,000 25°C (MIL-HDBK-217F) 0.98 Inches Free convection UL/cUL, TUV, 55022 class 55024
specifications valid nominal input voltage, full load +25°C after warm-up time unless otherwise stated.
Hiccup technique, auto-recovery
3000
3000
3000
3000
(89.0 63.5 25.0
Plastic resin Fiberglass (flammability 94V-0)
http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319
Encapsulated AC-DC Converter
SERIES
Watts
ELECTRICAL SPECIFICATIONS
Model Dual, Triple Output output wattage Voltage Frequency (Hz) Input Current (Full load) Inrush current (<2ms) Leakage Current External fuse (recommend) Voltage (V.DC.) Voltage accuracy Current (mA) Line regulation (typ.) Load regulation (5-100%) (typ.) Output Minimum load Maximum capacitive load Ripple Noise Efficiency Hold-up time Switching frequency Over current protection Protection Isolation Over voltage protection Short circuit protection Input-Output (V.AC) Operating temperature Storage temperature Environment Temperature coefficient Humidity MTBF Dimension Physical Case Material Weight Cooling method Safety Agency approvals (Conducted Emission) (Radiated Emission) ASC-5D 47-440 max. (115 VAC) max. (230 VAC) max. (115 VAC) max. (230 VAC) 0.75 max. slow blow type ±3000 ±12V ±1250 ±15V ±1000 5/12 3000/1250 ±1%/±5% ±3%/±6% 5/±12 3000/±630 ±1%/±5% ±2%/±6% 5/±15 3000/±500 ±1%/±5% ±2%/±6% ASC-12D ASC-15D ASC-5S12S ASC-5S12D ASC-5S15D
90-260 120-370
470-23,000µF depending model <0.5% Vout +50mV (Vp-p) min. Hiccup technique, auto-recovery Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000 -25°C.+71°C -40°C.+85°C 0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C >200,000 25°C (MIL-HDBK-217F) 0.98 Inches Free convection UL/cUL, TUV, 55022 class 55024
specifications valid nominal input voltage, full load +25°C after warm-up time unless otherwise stated.
3000
3000
3000
3000
3000
(89.0 63.5 25.0
Plastic resin Fiberglass (flammability 94V-0)
Note
triple output required minimum loading output maintain specified regulation. Operation under no-load condition will damage these devices; however they meet listed specification. Load regulation triple output: Main output (V1): 100% with 100% balanced auxiliaries. Auxiliary outputs V3): 100% balanced outputs. Cross regulation triple output: Main output 100% load, auxiliary 100%, other auxiliary 100%. Auxiliary outputs V3): Main output 100% load, auxiliary 100%, other auxiliary 100% main output 25%, auxiliary 25%, other auxiliary 100%.
http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319
Encapsulated AC-DC Converter
SERIES MECHANICAL DIMENSION (Top View)
PIN# SINGLE AC-N NOCONNECT Dual AC-N COMMON 5S/12S AC-N +12V
Watts
Triple AC-N OUT2 V2,V3 COMMON OUT3
BLOCK DIAGRAM
DERATING
http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319

Other recent searches


VREG-07 - VREG-07   VREG-07 Datasheet
MAX712 - MAX712   MAX712 Datasheet
MAX713 - MAX713   MAX713 Datasheet
LTC1565-31 - LTC1565-31   LTC1565-31 Datasheet
KS8803B - KS8803B   KS8803B Datasheet
KS8803B - KS8803B   KS8803B Datasheet
KBPC15005-KBPC1510 - KBPC15005-KBPC1510   KBPC15005-KBPC1510 Datasheet
CW901101 - CW901101   CW901101 Datasheet
CM300HA-12H - CM300HA-12H   CM300HA-12H Datasheet
AD7294 - AD7294   AD7294 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive