| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
G3PA-(VD) Extremely Thin Relays Integrated with Heat Sink Do
Top Searches for this datasheetPower Solid-state Relay G3PA-(VD) Extremely Thin Relays Integrated with Heat Sink Downsizing achieved through optimum design heat sink. Mounting possible screws track. Close mounting possible linking terminals. (Except G3PA-260B-VD, G3PA-450B-VD-2.) Applicable with 3-phase loads. Replaceable power element cartridges. Conforms 0160 (finger protection), with dielectric strength 4,000 between input load. Conforms 0805, 950. Approved CSA, (reinforced insulation). Ordering Information List Models Model G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-210BL-VD G3PA-220BL-VD G3PA-240BL-VD G3PA-260BL-VD G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-420B-VD G3PA-430B-VD G3PA-420B-VD-2 G3PA-430B-VD-2 G3PA-450B-VD-2 Isolation Phototriac coupler Zero cross function Indicator Applicable output load Rated input voltage Power Solid-state Relay G3PA-(VD) J-21 Replacement Parts Name Power Device Cartridge Carry current Load voltage Model G32A-A10-VD DC5-24 G32A-A10L-VD DC5-24 G32A-A10-VD AC24 G32A-A20-VD DC5-24 G32A-A20L-VD DC5-24 G32A-A20-VD AC24 G32A-A40-VD DC5-24 G32A-A40L-VD DC5-24 G32A-A40-VD AC24 G32A-A60-VD DC5-24 G32A-A60L-VD DC5-24 G32A-A60-VD AC24 G32A-A420-VD DC12-24 G32A-A430-VD DC12-24 G32A-A420-VD-2 DC12-24 G32A-A430-VD-2 DC12-24 G32A-A450-VD-2 DC12-24 G32A-A10 G32A-A20 G32A-A40 G32A-A420 G32A-A430 Applicable G3PA-210B-VD DC5-24 G3PA-210BL-VD DC5-24 G3PA-210B-VD AC24 G3PA-220B-VD DC5-24 G3PA-220BL-VD DC5-24 G3PA-220B-VD AC24 G3PA-240B-VD DC5-24 G3PA-240BL-VD DC5-24 G3PA-240B-VD AC24 G3PA-260B-VD DC5-24 G3PA-260BL-VD DC5-24 G3PA-260B-VD AC24 G3PA-420B-VD DC12-24 G3PA-430B-VD DC12-24 G3PA-420B-VD-2 DC12-24 G3PA-430B-VD-2 DC12-24 G3PA-450B-VD-2 DC12-24 G3PA-210B DC5-24 G3PA-220B DC5-24 G3PA-240B DC5-24 G3PA-420B DC5-24 G3PA-430B DC5-24 Conforms Other Units (Order Separately) Units that Enable 2-line Switching 3-phase Power Name Short-circuit Unit G32A-D40 Current flow G32A-D20 Model Applicable G3PA-210B-VD, G3PA-210BL-VD G3PA-220B-VD, G3PA-220BL-VD G3PA-420B-VD, G3PA-420B-VD-2 G3PA-430B-VD, G3PA-430B-VD-2 G3PA-240B-VD, G3PA-240BL-VD J-22 Power Solid-state Relay G3PA-(VD) Specifications Ratings 25°C) Input Model G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-210BL-VD G3PA-220BL-VD G3PA-240BL-VD G3PA-260BL-VD G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-420B-VD G3PA-430B-VD G3PA-420B-VD-2 G3PA-430B-VD-2 G3PA-450B-VD-2 max. max. min. 19.2 26.4 k±20% 19.2 max. min. max. max. min. Rated voltage Voltage range Input current impedance max. Voltage level Must operate voltage max. Must release voltage min. Output Model Rated load voltage G3PA-210B(L)-VD G3PA-220B(L)-VD G3PA-240B(L)-VD G3PA-260B(L)-VD G3PA-420B-VD G3PA-430B-VD G3PA-420B-VD-2 G3PA-430B-VD-2 G3PA-450B-VD-2 Refer Engineering Data further details. (50/60 (50/60 (50/60 (50/60 (50/60 Applicable load Load voltage range (50/60 Load current Inrush current cycle) cycle) cycle) cycle) cycle) cycle) cycle) cycle) cycle) Power Solid-state Relay G3PA-(VD) J-23 Characteristics Item G3PA210B(L)-VD G3PA220B(L)-VD G3PA240B(L)-VD G3PA260B(L)-VD G3PA420B-VD G3PA420B-VD-2 G3PA430B-VD G3PA430B-VD-2 G3PA450B-VD-2 Operate time load power source cycle max. Input, models) load power source cycle max. Input) max. (-BL models) Release time load power source cycle max. Input) load power source cycle max. Input) Output voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Approved standards (RMS) max. max. VAC) max. VAC) min. VDC) 4,000 VAC, 50/60 Destruction: 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted track) Destruction: m/s2 (mounted track) Operating: -30°C 80°C (with icing condensation) Storage: -30°C 100°C (with icing condensation) UL508, C22.2 (No.14, No.950), EN60950 File UL508, C22.2 (No.14), EN609474-3 File UL508, C22.2 (No.14), EN60947-4-3 File UL508, C22.2 (No.14), UL508, EN60947-4-3 File C22.2 (No.14), EN609474-3 File max. VAC) max. VAC) (RMS) max. max. VAC) max. VAC) max. VAC) max. VAC) Ambient humidity Weight Operating: Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. J-24 Power Solid-state Relay G3PA-(VD) Operation Replacement Parts G32A-A Power Device Cartridge G32A-A Power Device Cartridge Triac Unit) replaced with one. When temperature indicator changed from pink red, triac circuitry have malfunctioned possibly excessive flow current, which case, dismount damaged cartridge replacement. damaged cartridge replaced with without disconnecting wires from G3PA. Improve heat radiation efficiency G3PA before replacing cartridge. G32A-A Power Device Cartridge withstand excessive current short period time, such caused accidentally short circuitry load, which case temperature indicator will turn red. Appearance G32A-A10(L)-VD G32A-A20(L)-VD G32A-A40(L)-VD G32A-A60(L)-VD G32A-A10 G32A-A20 G32A-A40 G32A-A420-VD(-2) G32A-A430-VD(-2) G32A-A450-VD-2 Replacing Power Device Cartridges When replacing Power Device Cartridges, specified model. Using Power Device Cartridge other than specified will result faulty operation destruction elements. Noise Terminal Voltage according EN55011 Conformance EN55011 possible capacitor connected load power supply shown diagram below. (G3PA-VD) Recommended capacitor: NISSEI ELECTRIC Co., LTD, TYPE (MKT Series), (Japan only). Load Input G3PA-VD Loss Time loss time increases voltages currents. Ensure that loss time does increase inappropriate level. Loss time Caution sure turn power supply when replacing Cartridge. Supplying power with Cartridge removed result malfunction. Power Solid-state Relay G3PA-(VD) J-25 Replacement Procedure special tool (provided) extract cartridge replacement with one. Extraction Follow procedures below dismount Power Device Cartridge from G3PA. Switch power. Remove terminal cover. Hook indented part cartridge with tool pull cartridge remove Apply silicone grease here. Remover Hook here with Remover. Make sure that there dust pieces wire heat radiator G32A-A G3PA. Insert cartridge into opening G3PA that letters cartridge those G3PA same direction side side even. Side Side Mounting Follow procedures below mount Power Device Cartridge G3PA. Apply silicone grease (provided with G32A-A) entire surface heat radiator. Attach terminal cover. Switch power check G3PA sure works properly. G32A Power Device Cartridge mounted secured with screws G3PA Unit. Extraction Follow procedures below dismount G32A-A Power Device Cartridge from G3PA. Switch power. Remove terminal cover. Loosen centered screws sides dismount cartridge. screws connected terminals Mounting Apply silicone grease entire surface heat radiator. Loosen Apply silicone grease here. Make sure that there dust pieces wire radiator G32A-A G3PA. Loosen Loosen screws both corners. Loosen Loosen Hold indented part both corners dismount cartridge. J-26 Power Solid-state Relay G3PA-(VD) Insert cartridge into opening G3PA that side side even. Side Tighten screws both corners with tightening torque 0.59 0.78 Tighten screws both sides with tightening torque 0.59 0.78 Attach terminal cover. Switch power check G3PA sure works properly. Side Linking Terminal Connection Connecting with linking terminal G3PA-210B(L)-VD, -220B(L)VD, -240B(L)-VD G3PA-420B-VD(-2), G3PA-430B-VD(-2). SSR1 SSR2 SSR1 SSR2 Connecting with linking terminal G32A. G32A Unit G32A Unit cover will terminal protrudes. When SSRs close mounted, loosen M3.5 Sems screw flip linking terminal down. Insert linking terminal securely into center screw tighten screw. When close mounted, loosen M3.5 Sems screw G32A flip linking terminal down. Insert linking terminal securely into center screw tighten screw. Ensure that linking terminal does protrude. Linking terminal Refer instruction manual G32A-A Power Device Cartridge replace G3PA's triac part. Linking terminal G3PA-420B-VD Linking terminal Linking terminal When temperature indicator turned from pink red, G32-A-A Power Device Cartridge have malfunctioned, which case cartridge must replaced with one. terminal cover prevent accidents electric shock. Power Solid-state Relay G3PA-(VD) J-27 Connect terminal with power off. Mounting Screw track mounting possible. Vertical mounting should usually used. Vertical mounting Panel Close mounting also possible. Close mounting possible G3PA SSRs. there more SSRs, mount intervals min.) Reduce load current G3PA-210B-VD, -220B-VD, -240B-VD G3PA-260B-VD, 420B-VD(-2), -430B-VD(-2), -450B-VD-2. Leave distance rated ambient temperature 40°C. (30°C Close mounting Vertical Vertical Vertical track G3PA G3PA track Horizontal mounting Panel With vertical mounting, reduce load current 30%. (Refer Load Current Ambient Temperature graph.) Note: Leave distance min. between SSRs ducts (especially above SSR). J-28 Power Solid-state Relay G3PA-(VD) Engineering Data Load Current Ambient Temperature Horizontal Mounting Ground Panel Ground G3PA-210B(L)-VD, G3PA-220B(L)-VD G3PA-220B(L)-VD G3PA-240B(L)-VD G3PA-260B(L)-VD Load current Load current Load current G3PA-210B(L)-VD Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) G3PA-420B-VD, G3PA-420B-VD-2 G3PA-430B-VD, G3PA-430B-VD-2 G3PA-450B-VD-2 Load current Load current Ambient temperature (°C) Ambient temperature (°C) Load current Ambient temperature (°C) Note: Close mounting possible maximum three Units reducing load current 20%. minimum clearance must provided when mounting four more Units.) Power Solid-state Relay G3PA-(VD) J-29 Input Voltage Input Current G3PA-2@0B-VD Input impedance Input current (mA) Input current 25°C G3PA-4@0-VD, G3PA-4@-VD-2 Input impedance Input current (mA) 25°C Input current Input impedance Input impedance Input voltage Input voltage Vertical Mounting Ground Panel Ground G3PA-210B(L)-VD, G3PA-220B(L)-VD G3PA-240B(L)-VD G3PA-260B(L)-VD Load current Load current Load current G3PA-220B(L)-VD G3PA-210B(L)-VD Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) G3PA-420B-VD, G3PA-430B-VD G3PA-420B -VD-2, G3PA-430B-VD-2 G3PA-450B-VD-2 Load current G3PA-430B-VD G3PA-420B-VD Ambient temperature (°C) Load current Ambient temperature (°C) J-30 Power Solid-state Relay G3PA-(VD) Close Mounting Three) Panel Ground track G3PA-210B(L)-VD, G3PA-220B(L)-VD G3PA-240B(L)-VD G3PA-260B(L)-VD Load current Load current G3PA-220B-VD Load current G3PA-210B-VD Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) G3PA-420B-VD, G3PA-420B-VD-2 G3PA-430B-VD, G3PA-430B-VD-2 Load current Load current G3PA-450B-VD-2 Load current Ambient temperature (°C) Power Solid-state Relay G3PA-(VD) J-31 Ambient temperature (°C) Ambient temperature (°C) Inrush Current Resistivity: Non-repetitive Note: Keep inrush current half rated value occurs repetitively. G3PA-210B(L)-VD G3PA-220B(L)-VD, G3PA-420B-VD, G3PA-420B-VD-2 G3PA-240B(L)-VD/260B(L)-VD, G3PA-430B-VD, G3PA-430B-VD-2, G3PA-450B-VD-2 Inrush current Peak) Inrush current Peak) Energizing time (ms) Energizing time (ms) Inrush current Peak) Energizing time (ms) J-32 Power Solid-state Relay G3PA-(VD) Dimensions Note: units millimeters unless otherwise indicated. G3PA-210B(L)-VD Without Terminal Cover Two, Linking terminal With Terminal Cover dia. Mounting Holes Two, dia. holes Terminal Arrangement/ Internal Connections Trigger circuit Linking terminal elliptical hole max. G3PA-220B(L)-VD Without Terminal Cover Linking terminal Two, With Terminal Cover dia. Mounting Holes Two, dia. holes Terminal Arrangement/ Internal Connections Trigger circuit Linking terminal elliptical hole max. G3PA-240B(L)-VD Without Terminal Cover Linking terminal Two, With Terminal Cover dia. Mounting Holes Two, dia. holes Trigger circuit Linking terminal elliptical hole max. Power Solid-state Relay G3PA-(VD) Input circuit Two, M3.5 J-33 Terminal Arrangement/ Internal Connections Input circuit Two, M3.5 Input circuit Two, M3.5 G3PA-260B(L)-VD G3PA-450B-VD-2 With Terminal Cover dia. Without Terminal Cover Two, Two, M3.5 Mounting Holes Two, dia. holes Terminal Arrangement/ Internal Connections Trigger circuit elliptical hole max. max. G3PA-420B-VD, G3PA-420B-VD-2 Without Terminal Cover Two, Linking terminal 67+B1 Linking terminal With Terminal Cover dia. Mounting Holes Two, dia. Terminal Arrangement/ Internal Connections 90±0.2 Trigger circuit Input circuit max. 90±0.3 Two, M3.5 13.2 elliptic hole 25±0.2 max. max. G3PA-430B-VD, G3PA-430B-VD-2 Without Terminal Cover Two, Input circuit With Terminal Cover dia. Mounting Holes Two, dia. Terminal Arrangement/ Internal Connections Linking terminal Linking terminal 90±0.2 max. 90±0.3 elliptic hole 35±0.2 max. max. 35±0.3 J-34 Power Solid-state Relay G3PA-(VD) Trigger circuit Input circuit Precautions Refer Technical Information SSRs (Cat. J137) general precautions. Noise Terminal Voltage according EN55011 G3PA-(VD) conforms EN55011 standards when capacitor connected load power supply shown following circuit diagram. Load Input G3PA-(VD) Output Correct Load Connection load, power supply rated maximum operating frequency G3PA-(VD) built-in varistor overvoltage protection. applied voltage, such VAC, load current fully supplied. When Unit switched voltage required power Unit deprives output signal necessary voltage level thus creates loss time. lower load voltage greater loss time This condition, however, will create serious problems. Recommended Capacitor: NISSEI ELECTRIC Co., LTD, TYPE (MKT Series), Loss time load, diode should connected parallel load absorb counter electromotive force load. Load Input Load power supply When attaching heat sink G3PA-(VD), order facilitate heat dissipation, apply Silicone Grease equivalent heat conductive grease heat sink. (Toshiba Silicon, Shinetsu Silicon, etc.) Tighten mounting screws heat sink with torque 0.78 0.98 Power Solid-state Relay G3PA-(VD) J-35 DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. Cat. K094-E1-04 interest product improvement, specifications subject change without notice. J-36 Power Solid-state Relay G3PA-(VD) Other recent searchesSN74AHC123A - SN74AHC123A SN74AHC123A Datasheet SN54AHC123A - SN54AHC123A SN54AHC123A Datasheet PLT131 - PLT131 PLT131 Datasheet FX5545 - FX5545 FX5545 Datasheet FS14FS14- - FS14FS14- FS14FS14- Datasheet FS15FS15- - FS15FS15- FS15FS15- Datasheet 2SK2837 - 2SK2837 2SK2837 Datasheet 2SD2696 - 2SD2696 2SD2696 Datasheet 2SC5136 - 2SC5136 2SC5136 Datasheet 1N5391 - 1N5391 1N5391 Datasheet 1N5399 - 1N5399 1N5399 Datasheet
Privacy Policy | Disclaimer |