G3PA-(VD) Extremely Thin Relays Integrated with Heat Sink Do


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Power Solid-state Relay
G3PA-(VD)
Extremely Thin Relays Integrated with Heat Sink
Downsizing achieved through optimum design heat sink. Mounting possible screws track. Close mounting possible linking terminals. (Except G3PA-260B-VD, G3PA-450B-VD-2.) Applicable with 3-phase loads. Replaceable power element cartridges. Conforms 0160 (finger protection), with dielectric strength 4,000 between input load. Conforms 0805, 950. Approved CSA, (reinforced insulation).
Ordering Information
List Models
Model G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-210BL-VD G3PA-220BL-VD G3PA-240BL-VD G3PA-260BL-VD G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-420B-VD G3PA-430B-VD G3PA-420B-VD-2 G3PA-430B-VD-2 G3PA-450B-VD-2 Isolation Phototriac coupler Zero cross function Indicator Applicable output load Rated input voltage
Power Solid-state Relay
G3PA-(VD)
J-21
Replacement Parts
Name Power Device Cartridge Carry current Load voltage Model G32A-A10-VD DC5-24 G32A-A10L-VD DC5-24 G32A-A10-VD AC24 G32A-A20-VD DC5-24 G32A-A20L-VD DC5-24 G32A-A20-VD AC24 G32A-A40-VD DC5-24 G32A-A40L-VD DC5-24 G32A-A40-VD AC24 G32A-A60-VD DC5-24 G32A-A60L-VD DC5-24 G32A-A60-VD AC24 G32A-A420-VD DC12-24 G32A-A430-VD DC12-24 G32A-A420-VD-2 DC12-24 G32A-A430-VD-2 DC12-24 G32A-A450-VD-2 DC12-24 G32A-A10 G32A-A20 G32A-A40 G32A-A420 G32A-A430 Applicable G3PA-210B-VD DC5-24 G3PA-210BL-VD DC5-24 G3PA-210B-VD AC24 G3PA-220B-VD DC5-24 G3PA-220BL-VD DC5-24 G3PA-220B-VD AC24 G3PA-240B-VD DC5-24 G3PA-240BL-VD DC5-24 G3PA-240B-VD AC24 G3PA-260B-VD DC5-24 G3PA-260BL-VD DC5-24 G3PA-260B-VD AC24 G3PA-420B-VD DC12-24 G3PA-430B-VD DC12-24 G3PA-420B-VD-2 DC12-24 G3PA-430B-VD-2 DC12-24 G3PA-450B-VD-2 DC12-24 G3PA-210B DC5-24 G3PA-220B DC5-24 G3PA-240B DC5-24 G3PA-420B DC5-24 G3PA-430B DC5-24 Conforms
Other Units (Order Separately)
Units that Enable 2-line Switching 3-phase Power
Name Short-circuit Unit G32A-D40 Current flow G32A-D20 Model Applicable G3PA-210B-VD, G3PA-210BL-VD G3PA-220B-VD, G3PA-220BL-VD G3PA-420B-VD, G3PA-420B-VD-2 G3PA-430B-VD, G3PA-430B-VD-2 G3PA-240B-VD, G3PA-240BL-VD
J-22
Power Solid-state Relay G3PA-(VD)
Specifications
Ratings 25°C)
Input
Model G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-210BL-VD G3PA-220BL-VD G3PA-240BL-VD G3PA-260BL-VD G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-420B-VD G3PA-430B-VD G3PA-420B-VD-2 G3PA-430B-VD-2 G3PA-450B-VD-2 max. max. min. 19.2 26.4 k±20% 19.2 max. min. max. max. min. Rated voltage Voltage range Input current impedance max. Voltage level Must operate voltage max. Must release voltage min.
Output
Model Rated load voltage G3PA-210B(L)-VD G3PA-220B(L)-VD G3PA-240B(L)-VD G3PA-260B(L)-VD G3PA-420B-VD G3PA-430B-VD G3PA-420B-VD-2 G3PA-430B-VD-2 G3PA-450B-VD-2 Refer Engineering Data further details. (50/60 (50/60 (50/60 (50/60 (50/60 Applicable load Load voltage range (50/60 Load current Inrush current cycle) cycle) cycle) cycle) cycle) cycle) cycle) cycle) cycle)
Power Solid-state Relay
G3PA-(VD)
J-23
Characteristics
Item G3PA210B(L)-VD G3PA220B(L)-VD G3PA240B(L)-VD G3PA260B(L)-VD G3PA420B-VD G3PA420B-VD-2 G3PA430B-VD G3PA430B-VD-2 G3PA450B-VD-2 Operate time load power source cycle max. Input, models) load power source cycle max. Input) max. (-BL models) Release time load power source cycle max. Input) load power source cycle max. Input) Output voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Approved standards (RMS) max. max. VAC) max. VAC) min. VDC) 4,000 VAC, 50/60 Destruction: 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted track) Destruction: m/s2 (mounted track) Operating: -30°C 80°C (with icing condensation) Storage: -30°C 100°C (with icing condensation) UL508, C22.2 (No.14, No.950), EN60950 File UL508, C22.2 (No.14), EN609474-3 File UL508, C22.2 (No.14), EN60947-4-3 File UL508, C22.2 (No.14), UL508, EN60947-4-3 File C22.2 (No.14), EN609474-3 File max. VAC) max. VAC) (RMS) max. max. VAC) max. VAC) max. VAC) max. VAC)
Ambient humidity Weight
Operating: Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx.
J-24
Power Solid-state Relay G3PA-(VD)
Operation
Replacement Parts
G32A-A Power Device Cartridge
G32A-A Power Device Cartridge Triac Unit) replaced with one. When temperature indicator changed from pink red, triac circuitry have malfunctioned possibly excessive flow current, which case, dismount damaged cartridge replacement. damaged cartridge replaced with without disconnecting wires from G3PA. Improve heat radiation efficiency G3PA before replacing cartridge. G32A-A Power Device Cartridge withstand excessive current short period time, such caused accidentally short circuitry load, which case temperature indicator will turn red.
Appearance
G32A-A10(L)-VD G32A-A20(L)-VD G32A-A40(L)-VD G32A-A60(L)-VD G32A-A10
G32A-A20
G32A-A40
G32A-A420-VD(-2)
G32A-A430-VD(-2)
G32A-A450-VD-2
Replacing Power Device Cartridges
When replacing Power Device Cartridges, specified model. Using Power Device Cartridge other than specified will result faulty operation destruction elements.
Noise Terminal Voltage according EN55011
Conformance EN55011 possible capacitor connected load power supply shown diagram below. (G3PA-VD) Recommended capacitor: NISSEI ELECTRIC Co., LTD, TYPE (MKT Series), (Japan only).
Load Input G3PA-VD
Loss Time
loss time increases voltages currents. Ensure that loss time does increase inappropriate level.
Loss time
Caution
sure turn power supply when replacing Cartridge. Supplying power with Cartridge removed result malfunction.
Power Solid-state Relay
G3PA-(VD)
J-25
Replacement Procedure
special tool (provided) extract cartridge replacement with one.
Extraction
Follow procedures below dismount Power Device Cartridge from G3PA. Switch power. Remove terminal cover. Hook indented part cartridge with tool pull cartridge remove
Apply silicone grease here.
Remover Hook here with Remover.
Make sure that there dust pieces wire heat radiator G32A-A G3PA. Insert cartridge into opening G3PA that letters cartridge those G3PA same direction side side even.
Side
Side
Mounting
Follow procedures below mount Power Device Cartridge G3PA. Apply silicone grease (provided with G32A-A) entire surface heat radiator. Attach terminal cover. Switch power check G3PA sure works properly.
G32A Power Device Cartridge mounted secured with screws G3PA Unit.
Extraction
Follow procedures below dismount G32A-A Power Device Cartridge from G3PA. Switch power. Remove terminal cover. Loosen centered screws sides dismount cartridge. screws connected terminals
Mounting
Apply silicone grease entire surface heat radiator.
Loosen
Apply silicone grease here.
Make sure that there dust pieces wire radiator G32A-A G3PA.
Loosen
Loosen screws both corners.
Loosen
Loosen
Hold indented part both corners dismount cartridge.
J-26
Power Solid-state Relay G3PA-(VD)
Insert cartridge into opening G3PA that side side even.
Side
Tighten screws both corners with tightening torque 0.59 0.78 Tighten screws both sides with tightening torque 0.59 0.78 Attach terminal cover. Switch power check G3PA sure works properly.
Side
Linking Terminal Connection
Connecting with linking terminal G3PA-210B(L)-VD, -220B(L)VD, -240B(L)-VD G3PA-420B-VD(-2), G3PA-430B-VD(-2).
SSR1 SSR2 SSR1 SSR2
Connecting with linking terminal G32A.
G32A Unit G32A Unit
cover will terminal protrudes. When SSRs close mounted, loosen M3.5 Sems screw flip linking terminal down. Insert linking terminal securely into center screw tighten screw. When close mounted, loosen M3.5 Sems screw G32A flip linking terminal down. Insert linking terminal securely into center screw tighten screw. Ensure that linking terminal does protrude.
Linking terminal Refer instruction manual G32A-A Power Device Cartridge replace G3PA's triac part. Linking terminal
G3PA-420B-VD
Linking terminal
Linking terminal
When temperature indicator turned from pink red, G32-A-A Power Device Cartridge have malfunctioned, which case cartridge must replaced with one.
terminal cover prevent accidents electric shock.
Power Solid-state Relay
G3PA-(VD)
J-27
Connect terminal with power off.
Mounting
Screw track mounting possible. Vertical mounting should usually used.
Vertical mounting
Panel
Close mounting also possible. Close mounting possible G3PA SSRs. there more SSRs, mount intervals min.) Reduce load current G3PA-210B-VD, -220B-VD, -240B-VD G3PA-260B-VD, 420B-VD(-2), -430B-VD(-2), -450B-VD-2. Leave distance
rated ambient temperature 40°C. (30°C
Close mounting
Vertical Vertical Vertical
track
G3PA G3PA
track
Horizontal mounting
Panel
With vertical mounting, reduce load current 30%. (Refer Load Current Ambient Temperature graph.)
Note: Leave distance min. between SSRs ducts (especially above SSR).
J-28
Power Solid-state Relay G3PA-(VD)
Engineering Data
Load Current Ambient Temperature
Horizontal Mounting Ground
Panel
Ground
G3PA-210B(L)-VD, G3PA-220B(L)-VD
G3PA-220B(L)-VD
G3PA-240B(L)-VD
G3PA-260B(L)-VD
Load current
Load current
Load current
G3PA-210B(L)-VD
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
G3PA-420B-VD, G3PA-420B-VD-2
G3PA-430B-VD, G3PA-430B-VD-2
G3PA-450B-VD-2
Load current
Load current
Ambient temperature (°C)
Ambient temperature (°C)
Load current
Ambient temperature (°C)
Note: Close mounting possible maximum three Units reducing load current 20%. minimum clearance must provided when mounting four more Units.)
Power Solid-state Relay
G3PA-(VD)
J-29
Input Voltage Input Current
G3PA-2@0B-VD
Input impedance Input current (mA)
Input current 25°C
G3PA-4@0-VD, G3PA-4@-VD-2
Input impedance Input current (mA)
25°C
Input current
Input impedance
Input impedance
Input voltage
Input voltage
Vertical Mounting Ground
Panel
Ground
G3PA-210B(L)-VD, G3PA-220B(L)-VD
G3PA-240B(L)-VD
G3PA-260B(L)-VD
Load current
Load current
Load current
G3PA-220B(L)-VD
G3PA-210B(L)-VD
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
G3PA-420B-VD, G3PA-430B-VD G3PA-420B -VD-2, G3PA-430B-VD-2
G3PA-450B-VD-2
Load current
G3PA-430B-VD
G3PA-420B-VD
Ambient temperature (°C)
Load current
Ambient temperature (°C)
J-30
Power Solid-state Relay G3PA-(VD)
Close Mounting Three)
Panel
Ground
track
G3PA-210B(L)-VD, G3PA-220B(L)-VD
G3PA-240B(L)-VD
G3PA-260B(L)-VD
Load current
Load current
G3PA-220B-VD
Load current
G3PA-210B-VD
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
G3PA-420B-VD, G3PA-420B-VD-2
G3PA-430B-VD, G3PA-430B-VD-2
Load current
Load current
G3PA-450B-VD-2
Load current
Ambient temperature (°C)
Power Solid-state Relay
G3PA-(VD)
J-31
Ambient temperature (°C)
Ambient temperature (°C)
Inrush Current Resistivity: Non-repetitive
Note: Keep inrush current half rated value occurs repetitively.
G3PA-210B(L)-VD
G3PA-220B(L)-VD, G3PA-420B-VD, G3PA-420B-VD-2
G3PA-240B(L)-VD/260B(L)-VD, G3PA-430B-VD, G3PA-430B-VD-2, G3PA-450B-VD-2
Inrush current Peak)
Inrush current Peak)
Energizing time (ms)
Energizing time (ms)
Inrush current Peak)
Energizing time (ms)
J-32
Power Solid-state Relay G3PA-(VD)
Dimensions
Note: units millimeters unless otherwise indicated.
G3PA-210B(L)-VD
Without Terminal Cover
Two, Linking terminal
With Terminal Cover
dia.
Mounting Holes
Two, dia. holes
Terminal Arrangement/ Internal Connections
Trigger circuit
Linking terminal elliptical hole
max.
G3PA-220B(L)-VD
Without Terminal Cover
Linking terminal Two,
With Terminal Cover
dia.
Mounting Holes
Two, dia. holes
Terminal Arrangement/ Internal Connections
Trigger circuit
Linking terminal elliptical hole
max.
G3PA-240B(L)-VD
Without Terminal Cover
Linking terminal Two,
With Terminal Cover
dia.
Mounting Holes
Two, dia. holes
Trigger circuit
Linking terminal elliptical hole
max.
Power Solid-state Relay
G3PA-(VD)
Input circuit
Two, M3.5
J-33
Terminal Arrangement/ Internal Connections
Input circuit
Two, M3.5
Input circuit
Two, M3.5
G3PA-260B(L)-VD G3PA-450B-VD-2
With Terminal Cover
dia.
Without Terminal Cover
Two, Two, M3.5
Mounting Holes
Two, dia. holes
Terminal Arrangement/ Internal Connections
Trigger circuit
elliptical hole
max.
max.
G3PA-420B-VD, G3PA-420B-VD-2
Without Terminal Cover
Two,
Linking terminal 67+B1 Linking terminal
With Terminal Cover
dia.
Mounting Holes
Two, dia.
Terminal Arrangement/ Internal Connections
90±0.2
Trigger circuit Input circuit
max.
90±0.3
Two, M3.5 13.2 elliptic hole 25±0.2 max. max.
G3PA-430B-VD, G3PA-430B-VD-2
Without Terminal Cover
Two,
Input circuit
With Terminal Cover
dia.
Mounting Holes
Two, dia.
Terminal Arrangement/ Internal Connections
Linking terminal Linking terminal
90±0.2 max.
90±0.3
elliptic hole 35±0.2 max. max.
35±0.3
J-34
Power Solid-state Relay G3PA-(VD)
Trigger circuit
Input circuit
Precautions
Refer Technical Information SSRs (Cat. J137) general precautions.
Noise Terminal Voltage according EN55011
G3PA-(VD) conforms EN55011 standards when capacitor connected load power supply shown following circuit diagram.
Load Input G3PA-(VD) Output
Correct
Load Connection
load, power supply rated maximum operating frequency G3PA-(VD) built-in varistor overvoltage protection. applied voltage, such VAC, load current fully supplied. When Unit switched voltage required power Unit deprives output signal necessary voltage level thus creates loss time. lower load voltage greater loss time This condition, however, will create serious problems.
Recommended Capacitor: NISSEI ELECTRIC Co., LTD, TYPE (MKT Series),
Loss time
load, diode should connected parallel load absorb counter electromotive force load.
Load Input
Load power supply
When attaching heat sink G3PA-(VD), order facilitate heat dissipation, apply Silicone Grease equivalent heat conductive grease heat sink. (Toshiba Silicon, Shinetsu Silicon, etc.) Tighten mounting screws heat sink with torque 0.78 0.98
Power Solid-state Relay
G3PA-(VD)
J-35
DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. Cat. K094-E1-04 interest product improvement, specifications subject change without notice.
J-36
Power Solid-state Relay G3PA-(VD)

Other recent searches


SN74AHC123A - SN74AHC123A   SN74AHC123A Datasheet
SN54AHC123A - SN54AHC123A   SN54AHC123A Datasheet
PLT131 - PLT131   PLT131 Datasheet
FX5545 - FX5545   FX5545 Datasheet
FS14FS14- - FS14FS14-   FS14FS14- Datasheet
FS15FS15- - FS15FS15-   FS15FS15- Datasheet
2SK2837 - 2SK2837   2SK2837 Datasheet
2SD2696 - 2SD2696   2SD2696 Datasheet
2SC5136 - 2SC5136   2SC5136 Datasheet
1N5391 - 1N5391   1N5391 Datasheet
1N5399 - 1N5399   1N5399 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive