| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
models feature same compact dimensions provide uniform mounting pitch.
Top Searches for this datasheetWide Range Models with 40-A Output Currents 480-VAC/200-VDC Output Voltages models feature same compact dimensions provide uniform mounting pitch. Built-in varistor effectively absorb external surges. Operation indicator (red LED) enables monitoring operation. Protective cover greater safety. Standard models approved UL/CSA -UTU models G3NA Ordering Information Isolation Phototriac Photocou Photocoupler Phototriac Photocoupler ocou Zero cross function Indicator Rated output load (Applicable output load) VAC* VAC) Rated input voltage VAC* VAC) VAC* (180 VAC) -Phototriac Photocoupler ocou VDC) VAC* VAC) VAC* (180 VAC) Phototriac Photocoupler ocou VAC* VAC) VAC* (180 VAC) VAC* (180 VAC) *Loss time increases under VAC. (Refer page 164.) Note: When ordering model, "-UTU" model number shown below: Example: G3NA-210B-UTU G3NA-450B G3NA-440B G3NA-240B G3NA-420B G3NA-220B G3NA-D210B G3NA-410B G3NA-210B Model G3NA-205B G3NA Accessories (Order Separately) Heat Sink following heat sinks thin DIN-track mounted (except Y92B-P250). Dimensions details. Model Y92B-N50 Y92B-N100 Y92B-N150 Y92B-P250 Applicable G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B, G3NE-205T(L), G3NE-210T(L) G3NA-220B, G3NA-420B, G3NE-220T(L) G3NA-240B, G3NA-440B G3NA-450B Low-cost Models Model Y92B-A100 Y92B-A150N Y92B-A250 Applicable G3NA G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-220B, G3NA-410B, G3NA-420B G3NA-240B, G3NA-440B G3NA-440B Mounting Bracket Used mount G3NA with mounting dimension Model R99-11 Applicable G3NA-240B, G3NA-440B Dimensions details. (Refer page 164.) Specifications Ratings Input (Ambient Temperature: 25°C) Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage G3NA-2jjB G3NA-4jjB G3NA-D210B Note: max.* k±20% k±20% max.* k±20% max. max.** max.** max. max. Must release voltage min. min.** min.** min. min. input impedance measured maximum value rated supply voltage (for example, with model rated VAC, input impedance measured VAC). *With constant current input circuit system. impedance G3NA-jjjB-UTU max. **Refer Engineering Data further details. Output Model Rated load voltage G3NA-205B G3NA-210B G3NA-410B G3NA-220B G3NA-420B G3NA-240B G3NA-440B G3NA-450B G3NA-D210B Load voltage range Applicable load Load current With heat sink* Without heat sink cycle) cycle) cycle) cycle) Inrush current *When OMRON's heat sink (refer accessories) heat sink specified size used. G3NA Characteristics Item Operate time Release time Output voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Approved standards Ambient humidity Weight G3NA-205B, -210B, -220B G3NA-240B G3NA-410B, -420B, -440B, -450B G3NA G3NA-D210B max. input) max. input) max. input) max. input) max. max. VDC) load power source cycle max. input) load power source cycle max. input) load power source cycle max. input) load power source cycle max. input) (RMS) max. max. VAC) max. VAC) min. VDC) 2,500 VAC, 50/60 Malfunction: 1.5-mm double amplitude Malfunction: 1,000 m/s2 Operating: -30°C 80°C (with icing condensation) Storage: -30°C 100°C (with icing condensation) (RMS) max. max. VAC) max. VAC) UL508 File E64562/CSA C22.2 (No.0, No.14) File LR35535 (except G3NA-450B) R9151660 (EN60950) (except G3NA-4j0B) Operating: Approx. Approx. Approx. Approx. G3NA G3NA Engineering Data Load Current Ambient Temperature Characteristics G3NA-205B G3NA-210B/410B G3NA-220B/420B Load current Load current With standard heat sink (Y92B-A100 Y92BN50) aluminum plate measuring 13.2 Without heat sink With standard heat sink (Y92B-A100 Y92B-N50) aluminum plate measuring 13.2 With iron plate measuring Without heat sink Load current With standard heat sink (Y92B-A100 Y92B-N100) aluminum plate measuring 13.2 With iron plate measuring Without heat sink Ambient temperature (°C) G3NA-240B Ambient temperature (°C) G3NA-440B With Y92BA250 heat sink with radiation efficiency 1°C/W. With standard heat sink (Y92B-A150N Y92B-N150) Ambient temperature (°C) G3NA-D210B Load current Load current Load current With standard heat sink (Y92B-A150N Y92B-N150) With standard heat sink (Y92B-A100 Y92B-N50) aluminum plate measuring 13.2 With iron plate measuring Without heat sink With iron plate measuring Without heat sink With iron plate measuring Without heat sink Ambient temperature (°C) G3NA-450B Ambient temperature (°C) Ambient temperature (°C) With standard heat sink (Y92B-P250) Load current Without heat sink Ambient temperature (°C) G3NA Inrush Current Resistivity Non-repetitive (Keep inrush current half rated value occurs repetitively.) G3NA-205B G3NA-210B/410B G3NA-220B/420B G3NA Inrush current Peak) Inrush current Peak) Energizing time (ms) Energizing time (ms) Inrush current Peak) Energizing time (ms) Temperature Characteristics (with Must Operate Voltage Must Release Voltage) G3NA-240B/440B/450B G3NA-D210B G3NA-2jjB Input Inrush current Peak) Inrush current Peak) Energizing time (ms) Energizing time (ms) Variation rate Ambient temperature (°C) Heat Sink Size Load Current G3NA-220B Ambient temperature 80°C Ambient temperature 40°C Heat sink size (cm2 Note: heat sink size refers combined area sides heat sink that radiate heat. example, when current allowed flow through 40°C, graph shows that heat sink size about cm2. Therefore, heat sink square, side heat sink must (152 450) longer. Aluminum plate thick Load current G3NA G3NA Dimensions Note: units millimeters unless otherwise indicated. case surface mounting, derating load current required. orientation indicated external dimensions correct mounting orientation. When opening mounting holes, refer mounting hole dimensions. G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B Four, dia. screws Mounting Holes Terminal Arrangement/ Internal Connections (Top View) Load Load power supply Input Two, 4.3-dia. holes max. 47.5 Load 47.6±0.2 Operating indicator 13.8 max. max. max. G3NA-240B, G3NA-440B, G3NA-450B dia. Two, screws Mounting Holes Terminal Arrangement/ Internal Connections (Top View) Load Load power supply Input Two, 4.3-dia. holes min.47.5 Load 47.6±0.2 Operating indicator max. Two, M4x8 13.8 max. max. G3NA-D210B Four, dia. screws Mounting Holes Terminal Arrangement/ Internal Connections (Top View) Load Load power supply Input max. 47.5 Two, 4.3-dia. holes Load 47.6±0.2 max. Operating indicator 13.8 max. max. Note: load connected either positive negative side. Mounting Holes dia. Two, holes Two, holes Two, 3.2-dia. holes max. max. 90±0.4 max. 35±0.2 Heat Sink Y92B-N50 30.5±0.3 Two, 4.4-dia. holes 47.6 max. 90±0.3 max. Weight: approx. G3NA Y92B-N100 dia. Two, holes Two, holes G3NA Mounting Holes Two, 3.2-dia. holes 35±0.2 max. 30.5±0.3 max. Two, 4.4-dia. holes 90±0.4 47.6 max. 90±0.3 max. max. Weight: approx. Y92B-N150 dia. 47.6 Three, holes Two, 3.2-dia. holes Mounting Holes 35±0.2 max. max. 90±0.4 Two, 4.4-dia. holes 56±0.3 max. 90±0.3 max. max. Weight: approx. Y92B-A100 Y92B-A150N Three, holes Y92B-A250 Three, holes ±0.1 ±0.1 ±0.1 Two, holes 100.5 max. 80.5 max. R2.2 47.6 R2.2 47.6 47.6 50±0.1 max. 50±0.1 56±0.5 max. 50±0.1 56±0.5 max. 45.5 max. Mounting Holes Y92B-A100 Y92B-A150 Y92B-A250 Four, Four, 4.3-dia. holes Mounting Holes Four, dia. 190.5 max. 90±0.1 50±0.1 Four, R2.5 130.5 max. max. G3NA Y92B-P250 G3NA Four, Mounting Holes Four, dia. 190.5 max. Four, R2.5 130.5 max. max. R99-11 12.5 Mounting Bracket R99-11 that G3NA-240B mounted with same pitch that G3N-240B. Precautions Refer pages general precautions. Load Connection load, power supply rated maximum operating frequency G3NA built-in varistor overvoltage protection. applied voltage, such VAC, load current fully supplied. When Unit switched voltage required power Unit deprives output signal necessary voltage level thus creates loss time. lower load voltage greater loss time This condition, however, will create serious problems. Zero Cross Function with zero cross function operates when load voltage reaches zero point vicinity. This reduces clicking noises when load input, minimizes influence inductive load, such lamp, heater, motor, power supply because inrush current load reduced. This also minimize scale inrush current protection circuit. Loss time Output (load voltage) load, diode should connected parallel load absorb counter electromotive force load. Load Input Input Load power supply G3NA When attaching heat sink G3NA, apply Silicone Grease equivalent heat conductive grease heat sink. (Toshiba Silicon, Shinetsu Silicon, etc.) Tighten mounting screws heat sink with torque 0.78 0.98 EN55011 Measurement Mains Terminal Disturbance Voltage G3NA-UTU conforms EN55011 standards when capacitor connected load power supply shown following circuit diagram. Load Input G3NA-UTU Output G3NA Recommended Capacitor: Nissei Denki's MKT-series output terminal side G3NA-D210B connected builtin diode protecting from damage that result from reverse connection. SSR, however, cannot withstand minute more wires connected reverse order. Therefore, utmost attention make polarity mistakes load side. DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. Cat. K067-E1-1D Other recent searchesXDM2510HDK - XDM2510HDK XDM2510HDK Datasheet XDM2510HP - XDM2510HP XDM2510HP Datasheet XDM2510HC - XDM2510HC XDM2510HC Datasheet uPD720100A - uPD720100A uPD720100A Datasheet TS4851 - TS4851 TS4851 Datasheet TRC105 - TRC105 TRC105 Datasheet PA83A - PA83A PA83A Datasheet LTC2634 - LTC2634 LTC2634 Datasheet KPCA02-105 - KPCA02-105 KPCA02-105 Datasheet FW323 - FW323 FW323 Datasheet
Privacy Policy | Disclaimer |