The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

N4690 Series, 2-port Microwave ECal 85090 Series, 2-port ECal N4431B,


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Agilent Electronic Calibration (ECal) Modules Vector Network Analyzers
N4690 Series, 2-port Microwave ECal 85090 Series, 2-port ECal N4431B, 4-port ECal Technical Overview
Control ECal directly from VNAs 26.5 module module Nine connector types available Ideal calibration technique manufacturing Mixed-connectors available (Type-N ohm, 7-16)
Introduction
Electronic calibration (ECal) precision, single-connection, one-, two-, three-, four-port calibration technique your vector network analyzer. ECal modules fully traceable verifiable electronic impedance standards. modules state-of-the-art, solid-state devices with programmable highly repeatable impedance states. ECal modules transfer standards that provide consistent calibrations eliminate operator errors while bringing convenience simplicity your calibration routine. Consistent calibrations provide consistent measurements. ECal replaces traditional calibration technique, which uses mechanical standards. With mechanical standards required make numerous connections test ports single calibration. These traditional calibrations require intensive operator interaction, which prone error. With ECal, full one- four-port calibration accomplished with single connection ECal module minimal operator interaction. This results faster more repeatable calibrations. Mixed-connector options available 85092C, 85093C, 85098C, N4431B. available connectors Type-N ohms, 3.5mm, 7-16.
Accurate transfer standards
ECal modules transfer standards capable transferring factory calibration accuracy your network analyzer. They characterized Agilent using precision calibration technique (similar accuracy TRL) that traceable National Institute Standards Technology (NIST). Each calibration module's unique S-parameter data stored module's memory. During calibration, ECal uses this data calculate error terms your network analyzer. measurements either insertable non-insertable devices traceable NIST. reducing number connections required calibration, calibrate faster, save time make measurements sooner reduce chance operator error, greater confidence your calibrations reduce wear connectors, lower repair costs both test port connectors calibration standards
Network analyzer compatibility
85090 family ECal modules provides calibration across complete frequency range Series, series, 8753E/ES/ET vector network analyzers. N4690 family microwave ECal modules provides calibrations through 8719/20/22/D/ES/ET vector network analyzers through E8361/2/3/4 Microwave Series. N4431B four-port ECal module provides calibration N338x Series three-port PNAs.
Faster calibration with single connection
Unlike traditional mechanical technique, ECal only requires connection perform full one- four-port calibration from calibration module test ports.
Suggested ECal network analyzer/firmware compatibility
Agilent model number 8753E/ES/ET2 Series 8719D/ES/ET2, 8720D/ES/ET 8722D/ES/ET Series ENA-L Series Series PNA-L Series ECal module model number 85090 Series 85090 Series, N4431B N4690 Series N4690 Series N4690 Series N4431B, 85090 Series N4431B, 85090 Series N4690 Series N4431B, N4690 Series 85097B Required
complete compatibility refer ECal Reference Guide (publication N4693-9001) Analyzer firmware control available with firmware rev. 7.68. series consists E8356/7/8, E8801/2/3 N3381/2/3. N4431A supports N3381/2/3 PNAs with firmware revision higher. N4690 series supports 8719, 8720, 8722 network analyzers with firmware revision 7.74 higher. series consists E5070/1. ENA-L series consists E5061/2. microwave Series Network Analyzers consists E8361/2/3/4. PNA-L series consists N5230.
ECal Agilent Network Analyzer Configurations
Series
ECal modules controlled directly from Series network analyzers. external required. Simply connect ECal module port network analyzer. control your calibration from front panel keys Series automatically your user program.
8719, 8720, 8722 8753 product families
ECal modules controlled manually automatically 85097B interface kit. 85097B consists interface unit power supply. interface module interface between parallel port your VNA, parallel port ECal module external power supply. Firmware revisions 7.68 higher 8753 8720 families allow control ECal modules. 85097B interface module, with analyzer's internal firmware control, provides digital control supplies power ECal modules. Calibration control available front panel keys from user program. Firmware revision 7.74 adapter cable (8121-1047) required N4690 Series. adapter cable ordered option with 85097B.
Network analyzer
Parallel port connection
Calibration configuration using series
ECal module
interface unit
Optional ECal module
interface power supply power
Calibration configuration using 85097B interface
series consists E8356/7/8A, E8801/2/3A N3381/2/3A. series consists E5070/1. ENA-L series consists E5061/2.
Simple Non-insertable Calibrations
Most common microwave components have non-insertable connectors; example, devices with female connectors both ports. These devices require adapter removal calibration, which adds uncertainty factor measurement. Most modern vector network analyzers adapter removal technique, which compensates adaptercaused errors. simplest fastest noninsertable calibration method uses ECal module with connectors that match your device, same calibration method insertable devices. Simply order your ECal module with connectors that match your device under test: Option 00M, male connectors both ports Option 00F, female connectors both ports. Option with male female connector.
Perform adapter removal calibrations faster
Some analyzers, such later versions 8753 8720, offer adapter removal calibration non-insertable mixed connector measurement capability. Since this method requires full two-port calibrations, often time consuming prone operator errors. Using ECal perform two-port calibrations addresses both these concerns reducing calibration time number connections, simplifying overall adapter removal process.
Perform Usercharacterization
Normally, when perform calibration with ECal module, error terms calibration computed using factory characterization (data) stored module. User-characterization allows change characterization module ways: Change connector configuration: allows adapter fixture test port module embed effects into characterization module. result characterization extends reference plane from more module's test ports those adapter fixture). Modify state settings: allows specify number data points (1601 maximum) other stimulus settings module uses perform calibration. When perform user-characterization, factory characterization data remains stored module's memory. calibration, select factory characterization user-defined characterizations stored module. module store five user-defined characterizations addition factory characterization data). User-characterization available with Series Network Analyzers.
Test
ECal module
Power limits
Maximum input power Minimum input power
Electrical characteristic corrected performance
(Residual e-terms) 2-port ECal modules
Type-F
85099C (RF)1
Frequency range Directivity (dB) Source match (dB) Reflection tracking (±dB) 0.03 Transmission tracking (±dB) 0.08 Load match (dB) 0.07 0.10 0.15 0.17
85099C (RF)2
Frequency range Directivity (dB) Source match (dB) Reflection tracking (±dB) 0.06 Transmission tracking (±dB) 0.08 Load match (dB) 0.09 0.12 0.35 0.35
When mated with male connectors with 0.77 (0.030 0.86 (0.034 diameter Typical values when mated with male connectors with 0.56 (0.022 1.07 (0.042 diameter Except N469x modules, which typical
Type-N ohms)
85092C (RF)
Frequency range Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.04 0.04 0.04 0.04 0.06 0.07 0.07 0.14
N4690B (microwave)
Frequency range Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.07 0.12 0.05 0.08 0.03 0.07 0.03 0.07 0.05 0.12
Type-N ohms)
85096C (RF)
Frequency range Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.03 0.08 0.06 0.09 0.10 0.16
85093C (RF)
Frequency range Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.03 0.04 0.03 0.05 50.5 0.05 0.07 0.07 0.12
N4691B (microwave)
Frequency range Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.06 0.11 0.05 0.07 0.02 0.05 0.03 0.07 0.04 26.5 0.05 0.12
modules have precision slotless connectors that guarantee best calibration accuracy transferred your system.
85091C (RF)
Frequency range Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.04 0.06 0.04 0.06 0.07 0.13 0.10 0.23
N4696B (microwave)
Frequency range (GHz) Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.07 0.11 0.05 0.07 0.03 0.04 0.03 0.07 0.05
7-16
85098C (RF)
Frequency range Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.03 0.05 0.03 0.06 0.05 0.08 0.06 0.10
2.92
N4692A (microwave)
Frequency range (GHz) Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) MHz, typical 0.10 0.10 0.08 0.14 0.08 0.14 0.10 0.20 0.10 0.25
N4693A (microwave)
Frequency range (GHz) Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) MHz, typical 0.05 0.10 0.03 0.06 0.04 0.08 0.05 0.11 0.06 0.13 0.08 0.17
1.85
N4694A (microwave)
Frequency range (GHz) MHz, typical Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.05 0.15 0.04 0.07 0.04 0.05 0.11 0.06 0.13 0.07 0.15 0.08 0.19 0.09 0.25
4-port modules
Type-N ohms)
N4431B (RF), option
Frequency range Thru paths Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) Thru paths Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.03 0.07 0.04 0.09 0.04 0.13 0.05 0.15 0.06 0.16 0.11 0.32 0.03 0.07 0.04 0.10 0.04 0.14 0.05 0.20 0.06 0.22 0.11 0.35 13.5
N4431B (RF), option
Frequency range Thru paths Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) Thru paths Directivity (dB) Source match (dB) Reflection tracking (±dB) Transmission tracking (±dB) Load match (dB) 0.03 0.06 0.03 0.08 0.04 0.10 0.04 0.12 0.05 0.14 0.03 0.06 0.03 0.09 0.04 0.12 0.04 0.14 0.05 0.20 0.33 13.5
Ordering information
Select ECal module based connector type required frequency range your vector network analyzer (refer table below). Notes: Order 85097B interface module will using ECal with your 8719, 8720, 8722 8753. (Please reference ECal network analyzer/firmware compatibility table page 85097B consists interface module power supply. When using N469x ECal products with 8720 8753 network analyzer families, adapter cable (8121-1047) needed. This adapter cable orderable option with 85097B.
ECal modules available options
2-port
Connector Type Type-F Type-N ohms Type-N ohms Type-N ohms 7-16 2.92 1.85 Frequency range 26.5 ECal module Available options model number 85099C 85092C N4690B 85096C 85093C N4691B 85091C N4696B 85098C N4692A N4693A N4694A 00A, 00F, 00M, UK6, 00A, 00F, 00M, UK6, M0F, mixed-connectors 00A, 00F, 00M, UK6, 00A, 00F, 00M, UK6, 00A, 00F, 00M, UK6, M0F, mixed-connectors 00A, 00F, 00M, UK6, 00A, 00F, 00M, UK6, M0F, mixed-connectors 00A, 00F, 00M, UK6, 00A, 00F, 00M, UK6, 00A, 00F, 00M, UK6,
4-port
Connector Type Type-N ohms Frequency range 13.5 ECal module Available options model number N4431B 010, 020, UK6, mixed-connectors
Options
Option Description Replace connectors ECal module(s) with connectors Replace connectors ECal module(s) with connectors Adds male-to-male female-to-female adapters (also adds 5/16" N-cm in-lb) torque wrench modules) Commercial calibration certificate with measured data connectors ECal module(s) Four female, connectors Four female, Type-N connectors
N469x series modules cover frequency range kHz/10 GHz. upper frequency limited connector cutoff frequency. Each module supplied with torque wrench foam-padded wood storage box. 85090 series modules cover frequency range GHz, GHz. Each module supplied with torque wrench foam-padded wood storage box.
Mixed-connector options
2-port (85092C/3C/8C ECal modules only)
Port option Model number 85092C 85093C 85098C Type Type-N 7-161 Type Type-N Port option Type 7-161 7-161 Type-N
4-port (N4431B ECal module only)
Connector type Type-N Type-N 7-16 (f)1 7-16 (m)1 Port option Port option Port option Port option
Limits ECal module high frequency GHz.
Resources
Visit sites, additional product information literature. Electronic calibration (ECal): www.agilent.com/find/ecal Series network analyzers: www.agilent.com/find/pna Test measurement accessories:
Agilent Email Updates
latest information products applications select.
Agilent Technologies' Test Measurement Support, Services, Assistance Agilent Technologies aims maximize value receive, while minimizing your risk problems. strive ensure that test measurement capabilities paid obtain support need. extensive support resources services help choose right Agilent products your applications apply them successfully. Every instrument system sell global warranty. Support available least five years beyond production life product. concepts underlie Agilent's overall support policy: "Our Promise" "Your Advantage." Promise Promise means your Agilent test measurement equipment will meet advertised performance functionality. When choosing equipment, will help with product information, including realistic performance specifications practical recommendations from experienced test engineers. When receive your Agilent equipment, help verify that works properly help with initial product operation. Your Advantage Your Advantage means that Agilent offers wide range additional expert test measurement services, which purchase according your unique technical business needs. Solve problems efficiently gain competitive edge contracting with calibration, extra-cost upgrades, out-of-warranty repairs, onsite education training, well design, system integration, project management, other professional engineering services. Experienced Agilent engineers technicians worldwide help maximize your productivity, optimize return investment your Agilent instruments systems, obtain dependable measurement accuracy life those products. Agilent Software Connectivity Agilent's Test Measurement software connectivity products, solutions developer network allows take time connecting your instruments your computer with tools based standards, focus your tasks, your connections. Visit
more information. more information Agilent Technologies' products, applications services, please contact your local Agilent office. complete list available
www.agilent.com/find/contactus
Product specifications descriptions this document subject change without notice. Phone United States: (tel) 4444 (fax) 4433 Canada: (tel) 4414 (fax) 4866 China: (tel) 0189 (fax) 2816 Europe: (tel) 2111 Japan: (tel) (81) 7832 (fax) (81) 7840 Korea: (tel) (080) 0800 (fax) (080)769 0900 Latin America: (tel) (305) 7500 Taiwan: (tel) 0800 (fax) 0800 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com
Contacts revised: 9/17/04
Windows® Windows U.S. registered trademarks Microsoft Corp.
Agilent Technologies, Inc. 2002, 2003, 2004 Printed USA, November 2004 5963-3743E

Other recent searches


TRSL-5380-CXX0 - TRSL-5380-CXX0   TRSL-5380-CXX0 Datasheet
TRSL-5380C-CXX0 - TRSL-5380C-CXX0   TRSL-5380C-CXX0 Datasheet
SUD50N06-16 - SUD50N06-16   SUD50N06-16 Datasheet
MC10117 - MC10117   MC10117 Datasheet
MC10117P - MC10117P   MC10117P Datasheet
LTW-C230DS2 - LTW-C230DS2   LTW-C230DS2 Datasheet
ICS9112-18 - ICS9112-18   ICS9112-18 Datasheet
HMC610LP4 - HMC610LP4   HMC610LP4 Datasheet
EL6915 - EL6915   EL6915 Datasheet
FN7276 - FN7276   FN7276 Datasheet
BA3420AL - BA3420AL   BA3420AL Datasheet
1982420000 - 1982420000   1982420000 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive