Features Three-phase input High efficiency: full load 11.8 Watts/cubic


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



FE5A AC-DC Front Data Sheet Three-Phase Input, 5000 Watts
Features Three-phase input High efficiency: full load 11.8 Watts/cubic inch power density Power factor corrected minimum load required Single-wire current sharing Current limit over-voltage protection Full power Compact size: supply status indicators TUV, cTUVus report
Model Number FE5A-1D-0 FE5A-1E-0 FE5A-1F-0 FE5A-1G-0 FE5A-1H-0 FE5A-1J-0
Output Rating 12V/400A 15V/330A 24V/208A 28V/180A 36V/140A 48V/104A
Options (Output power good high); (Power fail high); (Reverse airflow)
Description ultra-compact FE5A Series Front-End Power Supply provides single isolated output 5000-Watts with inputs ranging from Vac, phase, handle frequencies from Designed high current applications requiring compact size. FE5A series operates either standalone unit part rack-mounted power systems. supply provides true front-end capability automatic test equipment, telecom, data communications, other distributed power designs. Input Specifications
Input voltage range: Vac, Nominal, Three Phase, Power Factor: >0.95 full load nominal line Inrush Current: peak cold start Input Protection: internal fuse line provided
Output Specifications
Output Power: 5000 maximum Output Voltage Current Ratings: chart shown above Overshoot/Undershoot: Less than turn-on turn-off. Less than 100% load step. Start-Up Time: Less than seconds Efficiency: typical measured full load, nominal input Hold-up Time: minimum full load line Overcurrent Protection: 105-130% full rated load with automatic recovery Overtemperature Protection: Automatic shutdown with auto recovery. Remote Sense: Compensates voltage drop load. Shorted sense lead protection. Overvoltage Protection: 120%-130% nominal; reset cycling input power. Output Noise Ripple: PARD: output voltage measured bandwidth. Single Wire Current Share: full load rating Load Regulation: 0.5% with remote sense, without Line Regulation: 0.2% over entire operating range Minimum Load: minimum load required
Signals Controls
Output Good Indicator: Front panel green indicates power supply good; amber indicates fault. Good Indicator: Front panel green indicates input voltage present above minimum level. Output Good Signal*: compatible signal, normally high. Goes when power supply specified range. Power Fail Signal*: compatible signal, normally high (indicating present above minimum level). Enable*: Normally High, drive enable. *All interface signals compatible
2006
Page
www.power-one.com
FE5A AC-DC Front Data Sheet Three-Phase Input, 5000 Watts
Safety Environmental
Temperature Range: Operating: 50°C Storage: -40°C +85°C Operating Humidity: Maximum non-condensing Operating Altitude: 10,000 feet Non-operating Altitude: 40,000 feet Temperature Coefficient: 0.01% within rated load Safety Agency Compliance: TUV, cTUVus report EMI: Meets EN55022, Class Harmonic Suppression: Meets EN6100-3-2 Input Transient Protection: Electrostatic Discharge: EN61000-4-2, Criteria Radiated, Radio-Frequency, Electromagnetic Field: EN61000-4-3, Criteria Electrical Fast Transients/Burst: EN61000-4-4, Criteria Voltage Fluctuations Flickers: EN61000-3-3, Criteria Surge Test: EN61000-4-5, Criteria Conducted Immunity: EN61000-4-6, Criteria
Safety Environmental (continued)
Dielectric Withstand: Input-to-ground: 2121 Input-to-output: 4242 Output-to-case: Leakage Current: maximum Vac,
Mechanical Specifications
Size: Input/Output Connector: Elcon Double Drawer male connector Mating Connector: Elcon Double Drawer female connector MTBF: 100,000 hours calculated 50°C, Bellcore Standard Warranty: years from date shipment, standard product only Specifications subject change without notice.
Outline Drawing Dimensions
2006
Page
www.power-one.com
FE5A AC-DC Front Data Sheet Three-Phase Input, 5000 Watts
Connector Descriptions
Number
Signal Name Output Output Output Output Chassis Ground I_Share_M Remote Sense DC_Enable (See Note
PF_HI (See Note Remote Sense SLogic_Rtn Pwr_OK (See Note Input Line Input Line Input Line
Notes turn output, short Dc-Enable Logic_Rtn, short Good: PF_Hi ref. Logic_Rtn Output Good: Pwr_OK ref. Logic_Rtn
NUCLEAR MEDICAL APPLICATIONS Power-One products designed, intended authorized critical components life support systems, equipment used hazardous environments, nuclear control systems without express written consent respective divisional president Power-One, Inc. TECHNICAL REVISIONS appearance products, including safety agency certifications pictured labels, change depending date manufactured. Specifications subject change without notice.
2006
Page
www.power-one.com

Other recent searches


SS4971 - SS4971   SS4971 Datasheet
SCHS140D - SCHS140D   SCHS140D Datasheet
MA4P290-1225T - MA4P290-1225T   MA4P290-1225T Datasheet
KSH45H11 - KSH45H11   KSH45H11 Datasheet
KSE45H - KSE45H   KSE45H Datasheet
HHM2406A1 - HHM2406A1   HHM2406A1 Datasheet
DS3762 - DS3762   DS3762 Datasheet
COM150A - COM150A   COM150A Datasheet
COM350A - COM350A   COM350A Datasheet
COM250A - COM250A   COM250A Datasheet
COM450A - COM450A   COM450A Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive