AC/DC Current transducer DHR-C5
transducer electronic measurement distorted waveform currents, with galvanic isolation between primary circuit (power) secondary circuit (measurement). True 0-5V voltage output.
100.1000
Primary Nominal Current (A.t.RMS) 1000 Primary Current Max. Peak Value 1000 1000 1800 1800 1800 Output voltage (Analog) (VDC) Type
Features
waveforms current measurement True output Panel mounting Eliminates insertion loss Insulated plastic case recognized according UL94-V0
1000
Load resistance Supply voltage Current consumption Output voltage limitation (0-5V) Overload capability (Ampere Turns)
30000
Advantages
Large aperture cable High isolation between primary secondary circuits Easy installation
Performance data
TCVOE TCVOUT
Accuracy IPN, 25°C (excluding offset) Linearity error IPN) Electrical offset voltage, 25°C Temperature coefficient 0.+60 (-40.+70 Temperature coefficient VOUT reading) Response time step Frequency bandwidth (±1dB)
mV/K mV/K 20.6000Hz
Applications
Controlled Loads output indicates motor attached load operating. Controlled Loads Acurate measurement phase angle fired burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement. Switching Power Supplies Electronic Ballasts True sensing most accurate measure power supply ballast input power.
General data
IPxx Ambient operating temperature Ambient storage temperature Mass Protection degree IP20
Note
Max. Peak Current highest peak level primary signal that taken into account accurate True calculation. device designed maximum continuous True value equal whereas output limited above specified output limitation.
Application domain
Energy Automation
Page
061128/14
reserves right carry modifications transducers, order improve them, without prior notice.
www.lem.com
Current Transducer DHR-C5
Isolation characteristics
Rated isolation voltage with 61010-1 acc. 61326 standards following conditions Reinforced isolation Over voltage category Pollution degree Heterogeneous field voltage isolation test 1min Creepage distance 8.89 Clearance distance 8.89 Comparative tracking index (Group
Note
Between primary (completely filling aperture) secondary.
Output polarity with input
Output
-Ipn
+Ipn
Safety
This transducer must used electric/electronic equipment with respect applicable standards safety requirements accordance with manufacturer's operating instructions. Installation maintenance should done with main power supply disconnected. operator must have accreditation install this material.
Caution! Risk electrical shock When operating transducer, certain parts module carry hazardous voltage (e.g. primary conductor, power supply). Ignoring this warning lead injury and/or cause serious damage. user must take care protection guarantee against electrical shock. This transducer built-in device, whose conducting parts must inaccessible after installation. protective housing additional shield could used.
Page
061128/14
reserves right carry modifications transducers, order improve them, without prior notice.
www.lem.com
Dimensions DHR-C5 0.0394 inch)
8.30
Connections
Wires DHR-C5/10 Female connector provided (screw terminals)
Mechanical characteristics
General tolerance Primary aperture Panel mounting Distance between holes 32.0 holes 70.0
(see above dimensions) panel mounting, replace screws (not supplied)
Output Connector 1(Vcc) 2(NC) 3(Vout) 4(GND) Power
with appropriate length thickness.
Remarks
Load
(Controller, meter etc)
+24VDC
VOUT positive when flows direction arrow. return busbar primary conductor elbow must located least window length more away from transducer case. temperature primary busbar exceed Dynamic performances best with primary busbar completely filling primary aperture. This standard model. different versions (supply voltages, different outputs, bidirectional measurements.), please contact
8.30
25.60
Page
061128/14
reserves right carry modifications transducers, order improve them, without prior notice.
www.lem.com

Other recent searches


VN5010AK-E - VN5010AK-E   VN5010AK-E Datasheet
SY69952 - SY69952   SY69952 Datasheet
MA46580 - MA46580   MA46580 Datasheet
MA46585 - MA46585   MA46585 Datasheet
DCS1800 - DCS1800   DCS1800 Datasheet
DCS1900 - DCS1900   DCS1900 Datasheet
CS10S - CS10S   CS10S Datasheet
CS50S - CS50S   CS50S Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive