transducer electronic measurement distorted waveform currents, with ga
Top Searches for this datasheetAC/DC Current transducer AHR-B10 transducer electronic measurement distorted waveform currents, with galvanic isolation between primary circuit (power) secondary circuit (measurement). True 0-10 voltage output. 2000 Primary nominal current rms) 1000 1500 2000 Primary current max. peak value 2000 2500 2000 2500 3000 Output voltage (Analog) (VDC) 0-10 0-10 0-10 0-10 0-10 Type Features distorted waveform currents measurement True output Busbar panel mounting Split core type Insulated plastic case recognized according UL94-V0. 1000 1500 2000 Load resistance Supply voltage Current Consumption Output voltage limitation Overload capability (Ampere Turns) 30000 Advantages High isolation between primary secondary circuits Eliminates insertion loss Easy installation. Performance data TCVOE TCVOUT Accuracy IPN, 25°C (excluding offset) Linearity error IPN) Electrical offset voltage, 25°C Temperature coefficient Temperature coefficient VOUT reading) Response time step Frequency bandwidth ±1.0 ±1.0 mV/K mV/K 0.15 6000Hz Applications power supplies Motors: True current sensing most accurate monitor power supply motor input power Controlled Loads: output current monitoring indicate motor attached load operating SCRs Switch-mode Rectifiers: Accurate measurement output current Renewable Energy Installations Backup Batteries: Continuous condition minitoring General data IPxx Ambient operating temperature Ambient storage temperature Mass Protection degree IP20 Note max. peak current highest peak level primary signal that taken into account accurate true r.m.s. calculation. device designed maximum continuous true r.m.s value equal whereas output limited above specified output limitation. allowing automatic failure detection/ anticipation. Application domain Energy Automation Page 061128/6 reserves right carry modifications transducers, order improve them, without prior notice. www.lem.com Current Transducer AHR-B10 Isolation characteristics Rated isolation voltage with 61010-1 according 61326 standards following conditions: Reinforced isolation Over voltage category Pollution degree Heterogeneous field voltage isolation test 1min Creepage distance 11.9 Clearance distance 11.9 Comparative tracking index (Group 250-399 Notes insulated cable used primary circuit, voltage category could improved according insulation characteristics given cable manufacturer. Between primary (completely filling aperture) secondary. Output polarity with input Output -Ipn +Ipn Safety This transducer must used electric/electronic equipment with respect applicable standards safety requirements accordance with manufacturer's operating instructions. Installation maintenance should done with main power supply disconnected. operator must have accreditation install this material. Caution! Risk electrical shock When operating transducer, certain parts module carry hazardous voltage (e.g. primary conductor, power supply). Ignoring this warning lead injury and/or cause serious damage. user must take care protection guarantee against electrical shock. This transducer built-in device, whose conducting parts must inaccessible after installation. protective housing additional shield could used. Page 061128/6 reserves right carry modifications transducers, order improve them, without prior notice. www.lem.com Dimensions AHR-B10 0.0394 inch) 9.10 0.50 54.10 20.34 Connections Wires Female connector provided (screw terminals) Output Connector 1(Vcc) 2(NC) 3(Vout) 4(GND) Mechanical characteristics General tolerance Primary aperture Busbar fastening Panel mounting Distance between hole axes hole slots holes Power Remarks return busbar primary conductor elbow must located minimum distance window length away from transducer case. temperature primary busbar exceed 90°C. Dynamic performances best with primary busbar completely filling primary aperture. This standard model. different versions (supply voltages, different outputs, bidirectional measurements.), please contact +24VDC Load (Controller, meter etc) Page 061128/6 reserves right carry modifications transducers, order improve them, without prior notice. www.lem.com Other recent searchesW24257 - W24257 W24257 Datasheet TDA4691 - TDA4691 TDA4691 Datasheet Sn100 - Sn100 Sn100 Datasheet PL1961 - PL1961 PL1961 Datasheet SiI3132 - SiI3132 SiI3132 Datasheet PCF8562 - PCF8562 PCF8562 Datasheet KSK-1A52-BV19613 - KSK-1A52-BV19613 KSK-1A52-BV19613 Datasheet ILD615 - ILD615 ILD615 Datasheet ILQ615 - ILQ615 ILQ615 Datasheet HHM1710D1 - HHM1710D1 HHM1710D1 Datasheet
Privacy Policy | Disclaimer |