AC/DC Current transducer AHR-B10
transducer electronic measurement distorted waveform currents, with galvanic isolation between primary circuit (power) secondary circuit (measurement). True 0-10 voltage output.
2000
Primary nominal current rms) 1000 1500 2000 Primary current max. peak value 2000 2500 2000 2500 3000 Output voltage (Analog) (VDC) 0-10 0-10 0-10 0-10 0-10 Type
Features
distorted waveform currents measurement True output Busbar panel mounting Split core type Insulated plastic case recognized according UL94-V0.
1000 1500 2000
Load resistance Supply voltage Current Consumption Output voltage limitation Overload capability (Ampere Turns)
30000
Advantages
High isolation between primary secondary circuits Eliminates insertion loss Easy installation.
Performance data
TCVOE TCVOUT
Accuracy IPN, 25°C (excluding offset) Linearity error IPN) Electrical offset voltage, 25°C Temperature coefficient Temperature coefficient VOUT reading) Response time step Frequency bandwidth
±1.0 ±1.0 mV/K mV/K 0.15 6000Hz
Applications
power supplies Motors: True current sensing most accurate monitor power supply motor input power Controlled Loads: output current monitoring indicate motor attached load operating SCRs Switch-mode Rectifiers: Accurate measurement output current Renewable Energy Installations Backup Batteries: Continuous condition minitoring
General data
IPxx Ambient operating temperature Ambient storage temperature Mass Protection degree IP20
Note
max. peak current highest peak level primary signal that taken into account accurate true r.m.s. calculation. device designed maximum continuous true r.m.s value equal whereas output limited above specified output limitation.
allowing automatic failure detection/ anticipation.
Application domain
Energy Automation
Page
061128/6
reserves right carry modifications transducers, order improve them, without prior notice.
www.lem.com
Current Transducer AHR-B10
Isolation characteristics
Rated isolation voltage with 61010-1 according 61326 standards following conditions: Reinforced isolation Over voltage category Pollution degree Heterogeneous field voltage isolation test 1min Creepage distance 11.9 Clearance distance 11.9 Comparative tracking index (Group 250-399
Notes insulated cable used primary circuit, voltage category could improved according insulation characteristics given cable manufacturer. Between primary (completely filling aperture) secondary.
Output polarity with input
Output
-Ipn
+Ipn
Safety
This transducer must used electric/electronic equipment with respect applicable standards safety requirements accordance with manufacturer's operating instructions. Installation maintenance should done with main power supply disconnected. operator must have accreditation install this material.
Caution! Risk electrical shock When operating transducer, certain parts module carry hazardous voltage (e.g. primary conductor, power supply). Ignoring this warning lead injury and/or cause serious damage. user must take care protection guarantee against electrical shock. This transducer built-in device, whose conducting parts must inaccessible after installation. protective housing additional shield could used.
Page
061128/6
reserves right carry modifications transducers, order improve them, without prior notice.
www.lem.com
Dimensions AHR-B10 0.0394 inch)
9.10
0.50
54.10 20.34
Connections
Wires Female connector provided (screw terminals)
Output Connector 1(Vcc) 2(NC) 3(Vout) 4(GND)
Mechanical characteristics
General tolerance Primary aperture Busbar fastening Panel mounting Distance between hole axes hole slots holes
Power
Remarks
return busbar primary conductor elbow must located minimum distance window length away from transducer case. temperature primary busbar exceed 90°C. Dynamic performances best with primary busbar completely filling primary aperture. This standard model. different versions (supply voltages, different outputs, bidirectional measurements.), please contact
+24VDC
Load
(Controller, meter etc)
Page
061128/6
reserves right carry modifications transducers, order improve them, without prior notice.
www.lem.com

Other recent searches


W24257 - W24257   W24257 Datasheet
TDA4691 - TDA4691   TDA4691 Datasheet
Sn100 - Sn100   Sn100 Datasheet
PL1961 - PL1961   PL1961 Datasheet
SiI3132 - SiI3132   SiI3132 Datasheet
PCF8562 - PCF8562   PCF8562 Datasheet
KSK-1A52-BV19613 - KSK-1A52-BV19613   KSK-1A52-BV19613 Datasheet
ILD615 - ILD615   ILD615 Datasheet
ILQ615 - ILQ615   ILQ615 Datasheet
HHM1710D1 - HHM1710D1   HHM1710D1 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive