Volt, Remote Power Volt, Remote Power Supply www.firelite.com Sec


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



DF-51401 D-100
Volt, Remote Power Volt, Remote Power Supply
www.firelite.com Section: Power Supplies/Accessories
FCPS-24F(E) FCPS-24F(E)
GENERAL
FireLite FCPS-24F(E) compact, cost-effective, 6amp remote power supply with battery charger. FCPS24F(E) connected 24-volt Fire Alarm Control Panel (FACP) stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion support requirements) auxiliary power support 24-volt system accessories. FCPS provides regulated filtered power four Notification Appliance Circuits (two Class [Style Class [Style four Class only). Alternately, four outputs configured combination resettable/non-resettable power outputs (optimal powering four-wire smoke detectors). FCPS-24F(E) also contains battery charger capable charging Hour batteries. CS868
California State Fire Marshal 7315-0075:176
(FCPS-24F)
(FCPS-24F FCPS-24FE)
S2424 S1287
(FCPS-24F)
(FCPS-24F)
387-94-E
FEATURES FEATURES
Requires input trigger voltage VDC. Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] jumpered permanently [standalone mode]). Class (Style Class (Style Notification Appliance Circuits (circuits additional NACs that individually configured Class (Style operation only (circuits full load output amps max./ckt.) expander mode 864). continuous output stand-alone mode 1481). stand-alone mode, output power circuits configured resettable (reset line from FACP required) non-resettable. Fully regulated filtered power output (optimal powering four-wire smoke detectors, annunciators other system peripherals requiring regulated/filtered power). Fuseless, power-limited technology meets powerlimiting requirements, effective 1995. Normally closed trouble contact. Fully supervised power supply, battery Notification Appliance Circuits. Selectable earth fault detection. trouble report selectable immediate, hour delay. Optional ammeter/voltmeter. Works with virtually fire alarm control which utilizes industry-standard reverse-polarity notification circuit.
Self-contained compact, lockable cabinet (15" [381 14.5" [368 2.75" Includes integral battery charger capable charging batteries. Fixed, clamp-type terminal blocks accommodate (3.25 wire.
STAND ANDARDS STANDARDS CODES
FCPS-24F complies with following standards: NFPA National Fire Alarm Code. Standard Control Units Fire Alarm Systems (NAC expander mode). 1481 Power Supplies Fire Alarm Systems (stand-alone mode).
FireLite® Alarms Honeywell company. This document intended used installation purposes. keep product information up-to-date accurate. cannot cover specific applications anticipate requirements. specifications subject change without notice. more information, contact FireLite Alarms, Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105.
DF-51401 07/13/04 Page
SPECIFICATIONS SPECIFICATIONS
Primary (AC) Power FCPS-24F: 50/60 max. FCPS-24FE: 220/240 50/60 max. Wire size: minimum (2.0 with 600V insulation. Control Input Circuit Trigger Input Voltage: VDC. Trigger Current: (per input) Trouble Contact Rating amps VDC.
Auxiliary Power Output Specific Application Power Short Circuit. Output Circuits (19.1 26.4) filtered, regulated. amps maximum circuit. amps maximum total continuous current outputs (Stand-alone mode). amps maximum total short-term current outputs (NAC Expander mode). Secondary Power (Battery) Charging Circuit Supports lead acid batteries only. Float Charge Voltage: 27.6V. Maximum Charge Current: Maximum Battery Capacity:
DESIGNATIONS TERMINAL DESIGNATIONS
Notes: listed external battery charger, MPM-4F ammeter/ voltmeter. R134 delay loss reporting hours (24-hour standby), R134 delay loss reporting hours (60-hour standby). R175 make output nonresettable stand-alone mode. R176 make output nonresettable stand-alone mode.
INFORMATION ORDERING INFORMATION
FCPS-24F Remote charger power supply (120 VAC). Includes main printed circuit board, transformers, enclosure, installation instructions. Remote charger power supply (220/240 VAC). Includes main printed circuit board, transformers, enclosure, installation instructions.
MPM-4F
A77-716B BAT-1270 MPM-4F
FCPS-24FE
12/24 end-of-line relay monitoring 4-wire smoke detector power. Battery, volt, (two required). Optional ammeter/voltmeter. Mounts FCPS backbox.
Page DF-51401 07/13/04
Application Examples
Example 1.0: Expand notification appliance power additional amps. Class (Style outputs Class (Style Class (Style outputs.
this example, FACP notification appliance circuits will activate FCPS-24F(E) when reverse polarity activation occurs. Trouble conditions FCPS-24F(E) sensed FACP through Notification Appliance Circuit
Example 2.0:
FCPS-24F(E) expand auxiliary regulated volt system power amps. Both non-resettable resettable power options available.
Resettable outputs created connecting resettable output from FACP both FCPS24F(E) inputs. Non-resettable outputs created simply cutting board resistors. addressable panel applications, monitor module sense trouble status FCPS-24F(E) trouble relay contacts.
Example 3.0:
addressable control modules activate FCPS-24F(E) versus FACP Notification Appliance Circuits. This typically allows mounting FCPS-24F(E) greater distances* away from FACP while expanding system architecture various applications.
this example, addressable control module used activate FCPS-24F(E) addressable monitor module used sense FCPS-24F(E) trouble conditions. Local auxiliary power output from FCPS-24F(E) provides power addressable control module. *The FireLite MS-9200, 198-point Addressable FACP capability locating control monitor modules 10,000 feet away.
DF-51401 07/13/04 Page

Other recent searches


RS6011Y - RS6011Y   RS6011Y Datasheet
REJ03F0024-0100Z - REJ03F0024-0100Z   REJ03F0024-0100Z Datasheet
IXDP2400 - IXDP2400   IXDP2400 Datasheet
IXDP2800 - IXDP2800   IXDP2800 Datasheet
IRF840B - IRF840B   IRF840B Datasheet
IRFS840B - IRFS840B   IRFS840B Datasheet
HRR11 - HRR11   HRR11 Datasheet
HMC171C8 - HMC171C8   HMC171C8 Datasheet
1792566 - 1792566   1792566 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive